This file is a spreadsheet attachment listing HVAC units and specifications for the Fort McHenry National Monument and Historic Shrine and Hampton National Historic Site preventative maintenance service contract. The document serves as an equipment inventory and technical reference for HVAC units that will be subject to preventative maintenance under solicitation 140P4226Q0043. The spreadsheet contains detailed information about the HVAC equipment located at these two National Park Service facilities in Maryland, including unit identifications, locations within the facilities, equipment specifications, and maintenance requirements. This attachment provides the technical foundation for contractors to understand the scope and complexity of the HVAC preventative maintenance services being solicited by the Department of the Interior National Park Service Northeast Region.

View the file

Other files

File Type Posted
Attachment_7_-_Revised_HAMP_HVAC_Units_0002.xlsx XLSX spreadsheet
Attachment_8_-_Q___A_0002.docx DOCX document
Sol_140P4226Q0043_Amd_0002.pdf PDF
Sol_140P4226Q0043_Amd_0001.pdf PDF
Attachment_2_-_Air_Filters_HAMP.xlsx XLSX spreadsheet
Attachment_4_HAMP_HVAC_Units.xlsx XLSX spreadsheet
Attachment_1_Air_Filters_FOMC.xlsx XLSX spreadsheet
Attachment_5_Wage_Determination_WD_15-4265_Rev_33.pdf PDF
Attachment_6_-_Quote_Submission_Package_140P4226Q0043.docx DOCX document
Sol_140P4226Q0043.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Fort McHenry HVAC Equipment
LocationUnit #QTY System ( QTY Sub Components INCL. System, Actuator, Auto Damper, Pump, Etc...)Unit #, [Equipment Description] (Services Location)BrandFilter & Belt Size / QTYModel1/4ly Maint. Minor - SCHEDULE:1/4ly Maint. Major - SCHEDULE:
VISITOR EDUCATION & ADMINISTRATION CENTER {BUILDING 108781}
Mechanical RoomHPU-11 (2)HPU #1, [Package Unit], (Cubical Area EAST) Incl. Hydronic ActuatorFlorida HP20 x 16 x 1EC015-VTNB & DA & C
Mechanical RoomHPU-21 (2)HPU #2, [Package Unit], (Cubical Area WEST) Incl. Hydronic ActuatorFlorida HP24 x 24 x 2EV030-3VTNB & DA & C
Mechanical RoomHPU-31 (2)HPU #3, [Package Unit], (2nd Floor Conference Room) Incl. Hydronic ActuatorFlorida HP20 x 20 x 2EV024-3VTNB & DA & C
Mechanical RoomHPU-41 (2)HPU #4, [Package Unit], (2nd FL Management Offices) Incl. Hydronic ActuatorFlorida HP24 x 30 x2EV060-3VTNB & DA & C
Mechanical RoomHPU-51 (2)HPU #5, [Package Unit], (2nd Floor Kitchen / Lunch Room)Florida HP24 x 30 x 2EV042-3VTNB & DA & C
Mechanical RoomERU1 (3)Energy Recovery Unit "ERU" [2-Stage] (Ground Loop Heat Exchange All Units) Incl. (Qty 2)Hydronic ActuatorsInnovent AirQty(4):16x25x4 +QTY(4): 16x25x2 + QTY(4)16x25x2 ((BELTs: QTY2: BP70 + Qty2: BP56))E5000-1/WAB & DA & C
Mechanical RoomHPU-61 (2)HPU #6, [Package Unit, {2-Stage}], (Exhibit Area, Lobby, Building Mixed Air) Incl. Hydronic ActuatorFlorida HP{(QTY4) 17 x 34 x 2} ((BELT QTY4: A-58))EC242-3HZNB & DA & C
Mechanical RoomHPU-71 (2)HPU #7, [Package Unit] (Multipurpose Eductation Room) Incl. Hydronic ActuatorFlorida HP24 x 30 x 2EV042-3VTNB & DA & C
Mechanical RoomHPU-81 (2)HPU #8, [Package Unit] (Gift Shop, Sales Office) Incl. Hydronic ActuatorFlorida HP20 x 20 x 2ES018-1CFNB & DA & C
Mechanical RoomHPU-91 (2)HPU #9, [Package Unit] (West Entrance Vesibule / Hall, NORTH) Incl. Hydronic ActuatorFlorida HP20 x 20 x 2ES018-1CFNB & DA & C
Mechanical RoomHPU-101 (2)HPU #10, [Package Unit], (Loading Dock Offices / Hallway) Incl. Hydronic ActuatorFlorida HP24 x 24 x 2EV030-3VTNB & DA & C
HPU-11
Mechanical RoomHPU-121 (2)HPU #12, [Package Unit] (West Entrance Vesibule / Hall, SOUTH) Incl. Hydronic ActuatorFlorida HP10 x 16 x 1EC012-1VTNB & DA & C
Exhibit CrawlspaceHPU-131 (2)HPU #13, [Package Unit], (East Entrance Vestibule) Incl. Hydronic ActuatorFlorida HP10 x 16 x 1EC012-1VTNB & DA & C
South StairwellHPU-141 (2)HPU #14, [Console Package Unit], (South Stairwell 1st Floor) Incl. Hydronic ActuatorFlorida HPWashableCA009-1URN-480B & DA & C
North StairwellHPU-151 (2)HPU #15, [Console Package Unit], (North Stairwell 1st Floor) Incl. Hydronic ActuatorFlorida HPWashableCA009-1URN-480B & DA & C
Mechanical RoomHPU-161 (2)HPU #16, [Console Package Unit], (Mechanical Room) Incl. Hydronic ActuatorFlorida HPWashableCA009-1URN-480B & DA & C
Audio Visual Control RoomHPU-171 (2)HPU #17, [Package Unit], (AV Control Room) Incl. Hydronic ActuatorFlorida HP24 x 30 x 2EV042-3VTNB & DA & C
Electrical Control RoomHPU-181HPU #18, [Console Package Unit], (Electrical Room)Florida HPWashableCA009-1URN-480B & DA & C
Mechanical RoomGSP-11Ground Loop Pump [Lead / Lag, 30 Day Auto Change Over]Armstrong4300325-083B & DA & C
Mechanical RoomGSP-21Ground Loop Pump [Lead / Lag, 30 Day Auto Change Over]Armstrong4300325-083B & DA & C
Elevator Machine Room1(2)Resistance Heater and Exhaust FanB & DA & C
Star Fort
Building "A" {BUILDING 27435}1 (4)(1) Condensing Gas Boiler (Single Zone), Incl. (2) Hydronic Pumps, Incl. (1) 115v Condensate PumpWeil McLainUltra 155BA
Building "C" {BUILDING 27440}1 (4)(1) Condensing Gas Boiler (Single Zone)Incl. (2) Hydronic Pumps, Incl. (1) 115v Condensate PumpWeil McLainUltra 105BA
1 (2)(1) Indirect Fired Water Heater, Incl. (1) Hydronic PumpsWeil McLainA
Building "D" {BUILDING 27441} Building "D" {BUILDING 27441}1 (7)(1) Condensing Gas Boiler (4 Zone) Incl. 5 Hydronic Pumps, Incl. (1) 115v Condensate PumpWeil McLainUltra 230BA
1 (2)(1) VRF (1) Low Profile 115v Condensate PumpMitsubishiC
4 (8)MiniSplit Cassett (4 Cassette's) Incl. (4) 230v Mini Condensate PumpsMitsubishiWashable FiltersC
1115v Centrifugal Exhaust Fan (Belt Drive)BAX37C11, C12, C13C11, C12, C13
Building "E" {BUILDING 27444}1 (5)Condensing Gas Boiler (2 Zone)Incl. (3) Hydronic Pumps, Incl. (1) 115v Condensate PumpWeil McLainUltra 230BA
1 (2)VRF (1) Low Profile 115v Condensate PumpMitsubishiC
3 (6)MiniSplit Cassett (3 Cassette's) Incl. (3) 230v Mini Condensate PumpsMitsubishiWashable FiltersC
1115v Centrifugal Exhaust Fan (Belt Drive)BAX 37C11, C12, C13C11, C12, C13
Civil War Powder Magazine {BUILDING 27446}
Ceiling1Fan Coil Unit With 2 Stage Electric HeatCarrierQTY2: 20 X 20 X 2FV4BNF003B & DA & C
Exterior Courtyard1Heat Pump Condenser Unit w/low ambient motor controlCarrier38YXA036330B & DA & C
Maintenance Shop {BUILDING 27511}
Front Office Area's1 (5)Gas Condensing Furnace (3 Zone Heat / Cool) Incl. (1) 115v Condensate Pump, Incl. (3) Damper ActuatorsBryant20 x 25 x 4CT9660-C212B & DA & C
Outside North End1CondenserBryant38BNE024301B & DA & C
Auto Shop Office1 (2)(1)Mini Split Cassette Evaporator, Incl. (1) Outdoor CondenserCarrierWashable Filter40MHHQ09---01 / 38MHRQ09A--01B & DA & C
Mission 66 Duplex Housing {BUILDING 27503}
North Unit1 (2)High Efficiency Condensing Gas Furnace w/ Split AC Package, Incl. (1) 115v Condensate PumpYork12 x 24 x 1YP9C060B12MP12CAB & DA & C
1Condenser UnitYorkYCJF30S41S1AB & DA & C
South Unit1 (2)High Efficiency Condensing Gas Furnace w/ Split AC Package, Incl. (1) 115v Condensate PumpYork12 x 24 x 1YP9C060B12MP12CAB & DA & C
1Condenser UnitYorkYCJF30S41S1AB & DA & C

Sheet2