This file is a spreadsheet attachment listing HVAC units and specifications for the Fort McHenry National Monument and Historic Shrine and Hampton National Historic Site preventative maintenance service contract. The document serves as an equipment inventory and technical reference for HVAC units that will be subject to preventative maintenance under solicitation 140P4226Q0043. The spreadsheet contains detailed information about the HVAC equipment located at these two National Park Service facilities in Maryland, including unit identifications, locations within the facilities, equipment specifications, and maintenance requirements. This attachment provides the technical foundation for contractors to understand the scope and complexity of the HVAC preventative maintenance services being solicited by the Department of the Interior National Park Service Northeast Region.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment_7_-_Revised_HAMP_HVAC_Units_0002.xlsx | XLSX spreadsheet | |
| Attachment_8_-_Q___A_0002.docx | DOCX document | |
| Sol_140P4226Q0043_Amd_0002.pdf | ||
| Sol_140P4226Q0043_Amd_0001.pdf | ||
| Attachment_2_-_Air_Filters_HAMP.xlsx | XLSX spreadsheet | |
| Attachment_4_HAMP_HVAC_Units.xlsx | XLSX spreadsheet | |
| Attachment_1_Air_Filters_FOMC.xlsx | XLSX spreadsheet | |
| Attachment_5_Wage_Determination_WD_15-4265_Rev_33.pdf | ||
| Attachment_6_-_Quote_Submission_Package_140P4226Q0043.docx | DOCX document | |
| Sol_140P4226Q0043.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Fort McHenry HVAC Equipment | ||||||||
| Location | Unit # | QTY System ( QTY Sub Components INCL. System, Actuator, Auto Damper, Pump, Etc...) | Unit #, [Equipment Description] (Services Location) | Brand | Filter & Belt Size / QTY | Model | 1/4ly Maint. Minor - SCHEDULE: | 1/4ly Maint. Major - SCHEDULE: |
| VISITOR EDUCATION & ADMINISTRATION CENTER {BUILDING 108781} | ||||||||
| Mechanical Room | HPU-1 | 1 (2) | HPU #1, [Package Unit], (Cubical Area EAST) Incl. Hydronic Actuator | Florida HP | 20 x 16 x 1 | EC015-VTN | B & D | A & C |
| Mechanical Room | HPU-2 | 1 (2) | HPU #2, [Package Unit], (Cubical Area WEST) Incl. Hydronic Actuator | Florida HP | 24 x 24 x 2 | EV030-3VTN | B & D | A & C |
| Mechanical Room | HPU-3 | 1 (2) | HPU #3, [Package Unit], (2nd Floor Conference Room) Incl. Hydronic Actuator | Florida HP | 20 x 20 x 2 | EV024-3VTN | B & D | A & C |
| Mechanical Room | HPU-4 | 1 (2) | HPU #4, [Package Unit], (2nd FL Management Offices) Incl. Hydronic Actuator | Florida HP | 24 x 30 x2 | EV060-3VTN | B & D | A & C |
| Mechanical Room | HPU-5 | 1 (2) | HPU #5, [Package Unit], (2nd Floor Kitchen / Lunch Room) | Florida HP | 24 x 30 x 2 | EV042-3VTN | B & D | A & C |
| Mechanical Room | ERU | 1 (3) | Energy Recovery Unit "ERU" [2-Stage] (Ground Loop Heat Exchange All Units) Incl. (Qty 2)Hydronic Actuators | Innovent Air | Qty(4):16x25x4 +QTY(4): 16x25x2 + QTY(4)16x25x2 ((BELTs: QTY2: BP70 + Qty2: BP56)) | E5000-1/WA | B & D | A & C |
| Mechanical Room | HPU-6 | 1 (2) | HPU #6, [Package Unit, {2-Stage}], (Exhibit Area, Lobby, Building Mixed Air) Incl. Hydronic Actuator | Florida HP | {(QTY4) 17 x 34 x 2} ((BELT QTY4: A-58)) | EC242-3HZN | B & D | A & C |
| Mechanical Room | HPU-7 | 1 (2) | HPU #7, [Package Unit] (Multipurpose Eductation Room) Incl. Hydronic Actuator | Florida HP | 24 x 30 x 2 | EV042-3VTN | B & D | A & C |
| Mechanical Room | HPU-8 | 1 (2) | HPU #8, [Package Unit] (Gift Shop, Sales Office) Incl. Hydronic Actuator | Florida HP | 20 x 20 x 2 | ES018-1CFN | B & D | A & C |
| Mechanical Room | HPU-9 | 1 (2) | HPU #9, [Package Unit] (West Entrance Vesibule / Hall, NORTH) Incl. Hydronic Actuator | Florida HP | 20 x 20 x 2 | ES018-1CFN | B & D | A & C |
| Mechanical Room | HPU-10 | 1 (2) | HPU #10, [Package Unit], (Loading Dock Offices / Hallway) Incl. Hydronic Actuator | Florida HP | 24 x 24 x 2 | EV030-3VTN | B & D | A & C |
| HPU-11 | ||||||||
| Mechanical Room | HPU-12 | 1 (2) | HPU #12, [Package Unit] (West Entrance Vesibule / Hall, SOUTH) Incl. Hydronic Actuator | Florida HP | 10 x 16 x 1 | EC012-1VTN | B & D | A & C |
| Exhibit Crawlspace | HPU-13 | 1 (2) | HPU #13, [Package Unit], (East Entrance Vestibule) Incl. Hydronic Actuator | Florida HP | 10 x 16 x 1 | EC012-1VTN | B & D | A & C |
| South Stairwell | HPU-14 | 1 (2) | HPU #14, [Console Package Unit], (South Stairwell 1st Floor) Incl. Hydronic Actuator | Florida HP | Washable | CA009-1URN-480 | B & D | A & C |
| North Stairwell | HPU-15 | 1 (2) | HPU #15, [Console Package Unit], (North Stairwell 1st Floor) Incl. Hydronic Actuator | Florida HP | Washable | CA009-1URN-480 | B & D | A & C |
| Mechanical Room | HPU-16 | 1 (2) | HPU #16, [Console Package Unit], (Mechanical Room) Incl. Hydronic Actuator | Florida HP | Washable | CA009-1URN-480 | B & D | A & C |
| Audio Visual Control Room | HPU-17 | 1 (2) | HPU #17, [Package Unit], (AV Control Room) Incl. Hydronic Actuator | Florida HP | 24 x 30 x 2 | EV042-3VTN | B & D | A & C |
| Electrical Control Room | HPU-18 | 1 | HPU #18, [Console Package Unit], (Electrical Room) | Florida HP | Washable | CA009-1URN-480 | B & D | A & C |
| Mechanical Room | GSP-1 | 1 | Ground Loop Pump [Lead / Lag, 30 Day Auto Change Over] | Armstrong | 4300325-083 | B & D | A & C | |
| Mechanical Room | GSP-2 | 1 | Ground Loop Pump [Lead / Lag, 30 Day Auto Change Over] | Armstrong | 4300325-083 | B & D | A & C | |
| Elevator Machine Room | 1(2) | Resistance Heater and Exhaust Fan | B & D | A & C | ||||
| Star Fort | ||||||||
| Building "A" {BUILDING 27435} | 1 (4) | (1) Condensing Gas Boiler (Single Zone), Incl. (2) Hydronic Pumps, Incl. (1) 115v Condensate Pump | Weil McLain | Ultra 155 | B | A | ||
| Building "C" {BUILDING 27440} | 1 (4) | (1) Condensing Gas Boiler (Single Zone)Incl. (2) Hydronic Pumps, Incl. (1) 115v Condensate Pump | Weil McLain | Ultra 105 | B | A | ||
| 1 (2) | (1) Indirect Fired Water Heater, Incl. (1) Hydronic Pumps | Weil McLain | A | |||||
| Building "D" {BUILDING 27441} Building "D" {BUILDING 27441} | 1 (7) | (1) Condensing Gas Boiler (4 Zone) Incl. 5 Hydronic Pumps, Incl. (1) 115v Condensate Pump | Weil McLain | Ultra 230 | B | A | ||
| 1 (2) | (1) VRF (1) Low Profile 115v Condensate Pump | Mitsubishi | C | |||||
| 4 (8) | MiniSplit Cassett (4 Cassette's) Incl. (4) 230v Mini Condensate Pumps | Mitsubishi | Washable Filters | C | ||||
| 1 | 115v Centrifugal Exhaust Fan (Belt Drive) | BAX37 | C11, C12, C13 | C11, C12, C13 | ||||
| Building "E" {BUILDING 27444} | 1 (5) | Condensing Gas Boiler (2 Zone)Incl. (3) Hydronic Pumps, Incl. (1) 115v Condensate Pump | Weil McLain | Ultra 230 | B | A | ||
| 1 (2) | VRF (1) Low Profile 115v Condensate Pump | Mitsubishi | C | |||||
| 3 (6) | MiniSplit Cassett (3 Cassette's) Incl. (3) 230v Mini Condensate Pumps | Mitsubishi | Washable Filters | C | ||||
| 1 | 115v Centrifugal Exhaust Fan (Belt Drive) | BAX 37 | C11, C12, C13 | C11, C12, C13 | ||||
| Civil War Powder Magazine {BUILDING 27446} | ||||||||
| Ceiling | 1 | Fan Coil Unit With 2 Stage Electric Heat | Carrier | QTY2: 20 X 20 X 2 | FV4BNF003 | B & D | A & C | |
| Exterior Courtyard | 1 | Heat Pump Condenser Unit w/low ambient motor control | Carrier | 38YXA036330 | B & D | A & C | ||
| Maintenance Shop {BUILDING 27511} | ||||||||
| Front Office Area's | 1 (5) | Gas Condensing Furnace (3 Zone Heat / Cool) Incl. (1) 115v Condensate Pump, Incl. (3) Damper Actuators | Bryant | 20 x 25 x 4 | CT9660-C212 | B & D | A & C | |
| Outside North End | 1 | Condenser | Bryant | 38BNE024301 | B & D | A & C | ||
| Auto Shop Office | 1 (2) | (1)Mini Split Cassette Evaporator, Incl. (1) Outdoor Condenser | Carrier | Washable Filter | 40MHHQ09---01 / 38MHRQ09A--01 | B & D | A & C | |
| Mission 66 Duplex Housing {BUILDING 27503} | ||||||||
| North Unit | 1 (2) | High Efficiency Condensing Gas Furnace w/ Split AC Package, Incl. (1) 115v Condensate Pump | York | 12 x 24 x 1 | YP9C060B12MP12CA | B & D | A & C | |
| 1 | Condenser Unit | York | YCJF30S41S1A | B & D | A & C | |||
| South Unit | 1 (2) | High Efficiency Condensing Gas Furnace w/ Split AC Package, Incl. (1) 115v Condensate Pump | York | 12 x 24 x 1 | YP9C060B12MP12CA | B & D | A & C | |
| 1 | Condenser Unit | York | YCJF30S41S1A | B & D | A & C |