ATTACHMENT 3 - Drawings 1 of 2.pdf
PDF 6 MB Posted
- Solicitation number
- 36C77623B0008
About this file
This solicitation seeks a general contractor to renovate approximately 7,700 square feet of existing space at the Oklahoma City VA Health Care System to support the deployment of new electronic health record management software and equipment. Key project details include renovating the EHRM Training Room and Administrative Support Space in the northwest area of the facility; furnishing all labor, materials, tools and equipment for the renovation; and supporting the Oklahoma City VA as well as its associated community-based outpatient clinics and other leased spaces. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA
57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COMFOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECTCONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of
Veterans Affairsof
/1
/2
:5
:0
P
M
CONSTRUCTION DOCUMENTS
05/12/2022
COVER SHEET
G0.00
EHRM TRAINING AND ADMIN
SPACE
JGCKP
921 NE 13TH ST
OKLAHOMA CITY, OK 73104Owner
VA259-16-D-0217
1 59
EHRM TRAINING AND ADMIN SPACE
PROJECT NO.
OKLAHOMA CITY VA HEALTH CARE SYSTEM
921 NE 13TH ST.
OKLAHOMA CITY, OK 73104
VA
U.S DEPARTMENT OF VETERAN'S AFFAIRS
VETERAN'S HEALTH ADMINISTRATION
VA259-16-D-0217
36C77621N3413
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA
57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COMFOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECTCONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of
Veterans Affairsof
/1
/2
:5
:1
P
M
CONSTRUCTION DOCUMENTS
05/12/2022
PROJECT DIRECTORY, DRAWING
INDEX
G0.01
EHRM TRAINING AND ADMIN
SPACE
JGCKP
921 NE 13TH ST
OKLAHOMA CITY, OK 73104Owner
VA259-16-D-0217
2 59
SHEET INDEX
GENERAL
G0.00 COVER SHEET
G0.01 PROJECT DIRECTORY, DRAWING INDEX
G0.02 ABBREVIATIONS, LEGENDS, SYMBOLS AND GENERAL NOTES
G-010 AREA FLOOR PLANS
G-011 CODE REVIEW PLAN
ARCHITETURE
AD1.00 DEMOLITION PLAN
A0.01 HEAD OF WALL DETAILS
A0.02 PARTITION FRAMING DETAILS
A1.00 NEW FLOOR PLANS
A1.10 DIMENSION PLAN
A1.30 WALL TYPES
A1.40 CEILING DETAILS
A1.41 REFLECTED CEILING PLANS
A3.00 BUILDING DEMO SECTIONS & BUILDING SECTIONS
A4.00 ENLARGED STAIR PLANS, SECTIONS AND DETAILS
A4.01 BUILDING SECTION, FLOOR PLANS AND DETAILS
A5.00 ROOM FINISH SCHEDULE
A5.01 FLOOR FINISH PLANS
A5.02 ENLARGED FLOOR PLAN, INTERIOR ELEVATIONS
A5.03 SIGNAGE SCHEDULE AND DETAILS
A6.00 DOOR SCHEDULE, ELEVATIONS AND DETAILS
INTERIOR FUNISHINGS
IF1.00 FURNISHINGS REFERENCE PLANS
STRUCTURAL
S0.00 STRUCTURAL GENERAL NOTES
S0.01 IBC INSPECTION TABLES
S1.00 EXISTING GROUND FLOOR & NEW SECOND FLOOR FRAMING PLAN
S5.00 DETAILS
S6.00 STANDARD DETAILS / SCHEDULES
MECHANICAL
M0.00 MECHANICAL ABBREVIATIONS, SYMBOLS, LEGENDS AND GENERAL NOTES
M0.01 MECHANICAL SCHEDULES
M0.02 MECHANICAL DETAILS
M0.03 MECHANICAL DETAILS
MD1.00 LOWER LEVEL HVAC DEMOLITION PLAN
MD1.10 UPPER LEVEL HVAC DEMOLITION PLAN
MH1.00 LOWER LEVEL HVAC NEW PLAN
MH1.10 UPPER LEVEL HVAC NEW PLAN
MP1.00 LOWER LEVEL HYDRONIC NEW PLAN
MP1.10 UPPER LEVEL HYDRONIC NEW PLAN
MH2.01 ENLARGED MEHCANICAL ROOM PLAN AND ELEVATIONS
M2.10 HVAC CONTROL DETAILS
MH3.00 MECHANICAL SECTIONS
MH3.01 ENLARGED MECHANICAL SECTIONS
M3.10 HVAC DUCT ISOMETRIC VIEW
M3.20 HYDRONIC PIPING ISOMETRIC VIEW
PLUMBING
P0.00 PLUMBING ABBREVIATIONS, SYMBOLS, LEGENDS AND GENERAL NOTES
PD1.00 PLUMBING DEMOLITION PLAN
P1.00 PLUMBING NEW PLAN
P2.00 PLUMBING ISOMETRIC VIEW
ELECTRICAL
E-000 ELECTRICAL LEGENDS AND ABBREVIATIONS
E-001 EXISTING ELECTRICAL PANEL SCHEDULES
E-002 ELECTRICAL SCHEDULES AND SCHEMATIC DIAGRAMS
E-003 ELECTRICAL DETAILS
ED-100 ELECTRICAL DEMOLITION PLANS
E-100 POWER PLANS
E-200 LIGHTING PLANS
E-300 SPECIAL SYSTEMS PLANS
FIRE PROTECTION
FP-100 FIRE PROTECTION SITE PLAN
FP-101 FIRE SPRINKLER PLANS
FA-100 FIRE ALARM SITE PLAN
FA-101 FIRE ALARM PLANS
ARCHITECT
KARL PERSON, AIA, LEED AP, NCARB
MECHANICAL/ELECTRICAL ENGINEER
RAY DAWES, PE
STRUCTURAL ENGINEER
LUCAS FRIED, PE
FOURFRONT DESIGN INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PHONE (605) 342-9470
ALBERTSON ENGINEERING INC.
3202 WEST MAIN ST, SUITE C
RAPID CITY, SOUTH DAKOTA 57702
PHONE (605) 343-9606
FIRE PROTECTION ENGINEER
MARK SORNSIN, PE, FIRE PROTECTION CONSULTANT
SUMMIT FIRE PROTECTION
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103PHONE
(651) 288-0781
# POUND OR NUMBER
& AND
@ AT
AB ANCHOR BOLT
ACI AMERICAN CONCRETE INSTITUTE
ACT ACOUSTIC CEILING TILE
AD AREA DRAIN
AFF ABOVE FINISH FLOOR
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
AISI AMERICAN IRON AND STEEL INSTITUTE
ALUM ALUMINUM
ANOD ANODIZED
ASD ALTERNATE STRESS DESIGN
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
AWS AMERICAN WELDING SOCIETY
BD BOARD
BLK BLOCK
BM BEAM
B.O. BOTTOM OF
BOT BOTTOM
BRG BEARING
BRKT BRACKET
BSMT BASEMENT
BLDG BUILDING
BYND BEYOND
CAB CABINET
CER CERAMIC
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
COMPR COMPRESSIBLE
CONC CONCRETE
CONST JT CONSTRUCTION JOINT
CONT CONTINUOUS
CPT CARPET TILE
CRSI CONCRETE REINFORCING STEEL INSTITUTE
DBL DOUBLE
DEMO DEMOLISH OR DEMOLITION
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DIR DIRECTION
DN DOWN
DR DOOR
DWG DRAWING
EA EACH
EE EACH END
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR OR ELEVATION
EPDM ETHYLENE PROPYLENE DIENE M-CLASS (ROOFING)
EQ EQUAL
ES EACH SIDE
EXIST. EXISTING
EXP BLT EXPANSION BOLT
EXP JT EXPANSION JOINT
EXT EXTERIOR
FD FLOOR DRAIN OR FIRE DEPARTMENT
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FIXT FIXTURE
FLR FLOOR
FM FILLED METAL
FND FOUNDATION
F.O. FACE OF
FT FOOT OR FEET
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GB GRADE BEAM
GP GUSSET PLATE
GR GRADE
GWB GYPSUM WALL BOARD
GYP GYPSUM
HC HOLLOW CORE
HDR HEADER
HEF HORIZONTAL EACH FACE
HI HIGH
HIF HORIZONTAL INSIDE FACE
HM HOLLOW METAL
HOF HORIZONTAL OUTSIDE FACE
HOR HORIZONTAL
HP HIGH POINT
HR HOUR
HS HIGH STRENGTH
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
ABBREVIATIONS
R RADIUS
RB RUBBER BASE
RBT RUBBER TILE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REINF REINFORCED
REF REFERENCE
REQD REQUIRED
RET RETURN
RM ROOM
R.O. ROUGH OPENING
ROW RIGHT OF WAY
SAB SOUND ATTENUATION BATTS
SC SOLID CORE
SECT SECTION
SHT SHEET
SIM SIMILAR
SL SPLICE LENGTH
SLC SEALED CONCRETE
SLV SHORT LEG VERTICAL
SOG SLAB ON GRADE
SPEC SPECIFIED OR SPECIFICATION
SPK SPRINKLER OR SPEAKER
SQ SQUARE
SSTL STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIFF STIFFENER
STL STEEL
STR STAIR
STRUCT STRUCTURE OR STRUCTURAL
SUP SUPPORT
SYM SYMMETRICAL
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TBD TO BE DETERMINED
T/D TELEPHONE/DATA
TEL TELEPHONE
TEMP TEMPERATURE
THK THICK OR THICKNESS
TLT TOILET
T.O. TOP OF
T.O.C TOP OF CONCRETE
T.O.F TOP OF FRAMING
T.O.S TOP OF STEEL/STUD
T.O.W TOP OF WALL
TPD TOILET PAPER DISPENSER
TYP TYPICAL
U/S UNDERSIDE
UNO UNLESS NOTED OTHERWISE
US UNDERSIDE
VB VAPOR BARRIER
VCT VINYL COMPOSITE TILE
VEF VERTICAL EACH FACE
VERT VERTICAL
VIF VERIFY IN FIELD
VWC VINYL WALL COVERING
W/ WITH
WD WOOD
WDW WINDOW
WP WORKING POINT
WRB WEATHER RESISTANT BARRIER
WWF WELDED WIRE FABRIC
FD FLOOR DRAIN OR FIRE DEPARTMENT
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FIXT FIXTURE
FLR FLOOR
FM FILLED METAL
FND FOUNDATION
F.O.M. FACE OF MASONRY
FT FOOT OR FEET
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GB GRADE BEAM
GP GUSSET PLATE
GR GRADE
GYP GYPSUM
HC HOLLOW CORE
HDR HEADER
HEF HORIZONTAL EACH FACE
HI HIGH
HIF HORIZONTAL INSIDE FACE
HM HOLLOW METAL
HOF HORIZONTAL OUTSIDE FACE
HOR HORIZONTAL
HP HIGH POINT
HR HOUR
HS HIGH STRENGTH
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
ICBO INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS
ID INSIDE DIAMETER
ILO IN LIEU OF
IN INCH
INCL INCLUDE
INSUL INSULATED OR INSULATION
INT INTERIOR
INV INVERT
IRGWB IMPACT RESISTANT GYPSUM WALL BOARD
JST JOIST
JT JOINT
K KIP (1000 POUNDS)
LLV LONG LEG VERTICAL
LP LOW POINT
LVL LEVEL
LW LIGHT WEIGHT
LWC LIGHT WEIGHT CONCRETE
MAS MASONRY
MAX MAXIMUM
MCB METAL CORNER BEAD
MECH MECHANICAL
MEMBR MEMBRANE
MEZZ MEZZANINE
MFR MANUFACTURED
MIN MINIMUM
M.O. MASONRY OPENING
MRGWB MOISTURE-RESISTANT GYPSUM WALL BOARD
MTL METAL
NF NEAR FACE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
NWC NORMAL WEIGHT CONCRETE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OPPOSITE HAND
OPNG OPENING
OZ OUNCE
P PAINT
PC PILE CAP
PCC PRE-CAST CONCRETE
PDF POWER DRIVEN FASTENER
PL PLATE
P.LAM PLASTIC LAMINATE
PLUMB PLUMBING
PLY PLYWOOD
PORC PORCELAIN
PNL PANEL
PNT PAINT OR PAINTED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PT POINT
PR PAIR
PROP PROPERTY
PVC POLYVINYL CHLORIDE
THE LIST OF ABBREVIATIONS MAY
CONTAIN ITEMS THAT ARE NOT SHOWN
ON THE DRAWINGS AND DO NOT OCCUR
IN THE PROJECT.
Room name
1t
VIEW NAME
1/8" = 1'-0"1 DRAWING TITLE
SCALE
BUILDING SECTION
DIRECTION OF SIGHT
DRAWING NUMBER
SHEET NUMBER
WALL SECTION
DETAIL CUT
A101
DETAIL CALLOUT
A101
A101
A101
A101
DIRECTION OF SIGHT
DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
EXTERIOR/INTERIOR
ELEVATION
DRAWING NUMBER
DIRECTION OF SIGHT
SHEET NUMBER
ROOM TAG
ROOM NAME
ROOM NUMBER
KEYNOTE TAG
5-04
KEYNOTE DESIGNATION
101 DOOR TAG
DOOR NUMBER
1i
PARTITION TAG
WALL DESIGNATION
WINDOW TAG
WINDOW DESIGNATION
ELEVATION MARKER
HEIGHT
NAME
ELEVATION
ARCHITECTURAL SYMBOLS
HEIGHT DESIGNATION(8'-0")
NORTH ARROW
DIRECTION OF PLAN NORTH
DIRECTION OF TRUE NORTH
PLAN
NORTH
V.A. SYMBOLS
FIRE RESISTIVE RATED LINE, 1 HOUR
FIRE RESISTIVE RATED LINE, 2 HOUR
FIRE RESISTIVE RATED LINE, 3 HOUR
FIRE RESISTIVE RATED LINE, 4 HOUR
FIRE-RATED, SMOKE BARRIER LINE, 1 HOUR
FIRE-RATED, SMOKE BARRIER LINE, 2 HOUR
FIRE-RATED, SMOKE BARRIER LINE, 3 HOUR
FIRE-RATED, SMOKE BARRIER LINE, 4 HOUR
V V ITEM - VA SUPPLIED AND INSTALLED
VC ITEM - VA SUPPLIED AND CONTRACTOR INSTALLED
CC ITEM - CONTRACTOR SUPPLIED AND INSTALLED
A
COLUMN GRID
DIMENSION LINE
NORTH ARROW
CL CENTER LINE
N
LEGEND NOTES:
1. THESE LEGENDS ARE COMPOSED OF STANDARD
SYMBOLS AND ARE PERNTINENT TO THE CONDITIONS
ON THIS SET OF DRAWINGS TO THE EXTENT
APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR OTHER LEGENDS MAY
APPEAR IN THIS SET OF DRAWINGS TO INDICATE
SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN
ON THIS SHEET.
1. ALL WORK SHALL COMPLY WITH APPLICABLE CODES,
REGULATIONS, AND ORDINANCES.
2. THE CONTRACTOR SHALL PERFORM ALL TESTING AND
INSPECTIONS AS SPECIFIED, OR AS NECESSARY TO
DEMONSTRATE A COMPLETE AND SATISFACTORY
INSTALLATION.
3. CONTRACTOR SHALL EXERCISE CAUTION TO AVOID ANY
DAMAGE WHEN PERFORMING EARTHWORK, PAVING, OR ANY
CONSTRUCTION IN THE VICINITY OF EXISTING UTILITIES.
4. CONTRACTOR SHALL INSPECT SITE AND FIELD VERIFY ALL
DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING
CONSTRUCTION. CONTRACTOR SHALL NOTIFY ARCHITECT
OF ANY DISCREPANCIES.
5. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS,
CONTRACTOR SHALL COORDINATE ALL WORK AND SHOP
DRAWINGS WITH OTHER TRADES.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION
OF ALL WORK. CONTRACTOR SHALL ANTICIPATE AREAS
WHERE THE INSTALLATION OF MECHANICAL AND ELECTRICAL
WORK WILL BE RESTRICTED, CONGESTED, OR DIFFICULT TO
INSTALL, AND SHALL COORDINATE INSTALLATION BETWEEN
ALL TRADES.
7. CONTRACTOR SHALL COORDINATE LOCATIONS FOR ALL
MECHANICAL AND ELECTRICAL ITEMS WITH THE GENERAL
CONTRACTOR. CONTRACTOR SHALL NOTIFY ARCHITECT OF
ANY DISCREPANCIES PRIOR TO INSTALLATION AND/OR
FABRICATION.
8. ALL BUILDING DIMENSIONS ARE TO FACE OF STUD, FACE OF
MASONRY, AND EXTERIOR WINDOW OR DOOR ROUGH
OPENING.
9. ALL ELEVATIONS INDICATED ON THE DRAWINGS ARE BASED
ON A FIRST FLOOR DATUM OF +100'-0”. WHERE ITEMS ARE
LABELED A.F.F. (ABOVE FINISHED FLOOR), CONTRACTOR
SHALL SET THE ITEM AS MEASURED FROM THE LOCAL FLOOR
ELEVATION. COORDINATE ANY DISCREPANCIES REGARDING
THIS SITUATION TO ASSURE THAT ALL BUILDING
COMPONENTS ARE PROPERLY SET TO FUNCTION AS
INTENDED.
10. SEE LIFE SAFETY PLANS FOR LOCATIONS OF FIRE- AND
SMOKE-RATED PARTITIONS.
11. INSTALL BLOCKING WITHIN PARTITIONS AS REQUIRED FOR
INSTALLATION OF WALL-MOUNTED CABINETS, TOILET
ACCESSORIES, WALL STOPS, AND MISCELLANEOUS ITEMS.
12. ALL CEILING HEIGHTS LISTED IN THE ROOM FINISH SCHEDULE
ARE FROM THE FINISH FLOOR OF THE LISTED ROOM, UNLESS
NOTED OTHERWISE.
13. ALL CHANGES IN FLOOR MATERIALS OCCUR AT THE
FOLLOWING LOCATIONS, UNLESS NOTED OTHERWISE: 1) AT
THE CENTER LINE OF DOORS IN THE CLOSED POSITION, OR;
2) AT THE CENTER LINE OF OPENINGS SEPARATING ROOMS.
14. THE PLANS AND SPECIFICATIONS ARE NOT INTENDED TO
DEPICT EACH AND EVERY CONDITION OR DETAIL OF
CONSTRUCTION IN REGARD TO THE AIR AND MOISTURE
RETARDER.
15. REFER TO SPECIFICATIONS FOR FF&E JSN NUMBER
DESCRIPTION, ACQUISITION AND INSTALLATION.
GENERAL NOTES:
STEEL/METAL
WOOD (ROUGH) BLOCKING OR SHIM
BRICK
GRAVEL
EARTH/ENGINEERED FILL
CONCRETE MASONRY
PLAN AND SECTION
WOOD (ROUGH)
ACOUSTIC CEILING TILE (ACT1)
CEILING
CONCRETE
ELEVATION
CENTER LINE
LINE SYMBOLS
GRID LINE
PROPERTY LINE
CUT LINE
MINERAL WOOL INSULATION
WOOD SUBSTRATE
RIGID INSULATION
MATERIAL LEGEND
WM - WALK OFF MAT
RFT1
FLOORING
BID ALTERNATE
CPT1 - CARPET
CONC - CONCRETE
QT1
BRICK
VERTICAL STANDING SEAM METAL PANEL,
STANDING SEAM METAL ROOF
METAL PANELING - 22"W
GYPSUM BOARD
ACOUSTIC CEILING TILE (ACT2)
WOOD SLAT CEILING TILE (ACT3)
CPT2 - CARPET
CPT3 - CARPET
CPT4 - CARPET
RSF1
RSF2
PT1 - PORCELAIN TILE
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA
57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COMFOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECTCONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of
Veterans Affairsof
/1
/2
:5
:1
P
M
CONSTRUCTION DOCUMENTS
05/12/2022
ABBREVIATIONS, LEGENDS, SYMBOLS
AND GENERAL NOTES
G0.02
EHRM TRAINING AND ADMIN
SPACE
JGCKP
921 NE 13TH ST
OKLAHOMA CITY, OK 73104Owner
VA259-16-D-0217
3 59
UP
DN
DNDN
DN
LIMITS OF PROJECT/CONSTRUCTION
UNDER THIS CONTRACT.
AREA OF WORK NOT IN THE SCOPE.
EXISTING TO REMAIN.
NEW PLAN AREA LEGEND:
4877 SF
FIRST LEVEL AREA
235 SF
BREAK ROOM
OA1
195 SF
OFFICE
OA2
400 SF
OPEN OFFICE
OA3
108 SF
STORAGE
OA4
157 SF
OFFICE
OA5
696 SF
OPEN OFFICE
OA6
839 SF
CORRIDOR
CO1
101 SF
STORAGE
186 SF
STORAGE
40 SF
TOILET
40 SF
TOILET
40 SF
TOILET
40 SF
TOILET
619 SF
MEETING ROOM
640 SF
MEETING ROOM
54 SF
HAC
FE
FE
FE
F E
C
FEC
462 SF
MEETING ROOM
475 SF
MEETING ROOM
535 SF
MEETING ROOM
527 SF
MEETING ROOM
406 SF
CORRIDOR
CO2
3453 SF
UPPER LEVEL AREA
37 SF
ELECTRICAL
ROOM
235 SF
BREAK ROOM
OA1
586 SF
MECHANICAL
F E
C
F E
FEC
20 SF
STORAGE
20 SF
MECHANICAL
EXISTING WALL RATING:
2 HOUR FIRE BARRIER
SMOKE RESISTIVE HAZARDOUS
ROOM ENCLOSURE
FE EXISTING FIRE EXTINGUISHER
LIFE SAFETY LEGEND:
MEANS OF EGRESS:
TRAVEL DISTANCE
COMMON PATH
EXIT DISCHARGE
DEAD-END CORRIDOR
PROVIDED CLEAR DOOR WIDTH (INCHES)
MAX OCCUPANT LOAD CAPACITY (NO. OF PEOPLE)
DOOR TAG
WALL RATING:
1 HOUR FIRE BARRIER
1. SHEET SIZE FOR PROPER SCALE IS 30X42.
CONTRACTOR SHALL NOT SCALE DRAWINGS
BUT SHALL REQUEST DESIRED DIMENSIONS
FROM ARCHITECT.
2. SEE SHEET G-002 FOR GENERAL NOTES.
3. MECHANICAL AND ELECTRICAL ITEMS
SHOWN ON THE RCP DRAWINGS ARE FOR
REFERENCE ONLY. FINAL LOCATION OF
MECHANICAL AND ELECTRICAL FIXTURE
WILL NEED TO BE COORDINATED WITH
ARCHITECTURE AND INTERIORS.
4. REFER TO ELECTRICAL DRAWING FOR ALL
ELECTRICAL CEILING FIXTURE SYMBOLS.
NOT ALL ELECTRICAL SYMBOLS ARE
INDICATED IN THE REFLECTED CEILING
LEGEND.
5. ALL CEILING MOUNTED ITEMS SHALL BE
LOCATED IN THE CENTER OF THE ACOUSTIC
CEILING PANEL UNLESS NOTED
OTHERWISE.
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA
57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COMFOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECTCONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of
Veterans Affairsof
/1
/2
:5
:1
P
M
CONSTRUCTION DOCUMENTS
05/12/2022
AREA FLOOR PLANS
G-010
EHRM TRAINING AND ADMIN
SPACE
JGCKP
921 NE 13TH ST
OKLAHOMA CITY, OK 73104Owner
VA259-16-D-0217
4 59
TOTAL BUILDING GROSS AREA
Name Area
FIRST LEVEL AREA 4877 SF
UPPER LEVEL AREA 3453 SF
Total 8330 SF
NET ROOM AREA SCHEDULE - ADNMIN/TRAINING
No. Name Area
1 MEETING ROOM 619 SF
2 MEETING ROOM 640 SF
3 TOILET 40 SF
4 TOILET 40 SF
5 STORAGE 101 SF
6 STORAGE 186 SF
7 TOILET 40 SF
8 TOILET 40 SF
9 HAC 54 SF
CO1 CORRIDOR 839 SF
OA1 BREAK ROOM 235 SF
OA1A STAIRS 54 SF
OA2 OFFICE 195 SF
OA3 OPEN OFFICE 400 SF
OA4 STORAGE 108 SF
OA5 OFFICE 157 SF
OA6 OPEN OFFICE 696 SF
10 MEETING ROOM 462 SF
11 MEETING ROOM 475 SF
12 MEETING ROOM 527 SF
13 MEETING ROOM 535 SF
15 STORAGE 20 SF
16 STAIRS 94 SF
17 STAIRS 90 SF
18 ELECTRICAL ROOM 37 SF
19 MECHANICAL 586 SF
20 MECHANICAL 20 SF
CO2 CORRIDOR 406 SF
NET ROOM TOTAL: 28 7697 SF
1/8" = 1'-0"
AREA FLOOR PLAN - LEVEL 1
1/8" = 1'-0"
AREA FLOOR PLAN - LEVEL 2
GENERAL NOTES:
TRUE
NORTH
N
TRUE
NORTH
N
DN
UP
DNDN
DN
MEETING ROOM
MEETING ROOM
STORAGE
5 STORAGE
TOILET
TOILET
TOILET
TOILET
BREAK ROOM
OA1
OFFICE
OA2
OPEN OFFICE
OA3
STORAGE
OA4
OFFICE
OA5
OPEN OFFICE
OA6
CORRIDOR
CO1
FE
FE
FE
HAC
TOILET FEMALE
GB112
VOLUNTEER
INFORMATION
GB113
VOLUNTEER
SERVICE
GD107
ROOM
GD101
E L
E C
G D
CHIEF
VOLUNTEER
SERVICE
GD108
CORRIDOR
CG-2D
CORRIDOR
CG-1D
VESTIBULE
CG-1R
C O
R R
ID
O
R
C G
-2 R
PHYSICAL REHAB
GR119
STORAGE
GR100
ROOM
GR101
ROOM
GR102
CORRIDOR
CG-5R
F E
C
EXIT
#1
EXIT
#3
T D
CP#1 = 62' - 0"
TD#2 = 22'- 0"
CP#2 = 46' - 6"
TD#3 = 76' - 0"
TD#4 = 96' - 0"
TYPE II(000)
CONSTRUCTION
ASSEMBLY OCCUPANCY
TYPE II(222)
CONSTRUCTION
BUSINESS OCCUPANCY
FEC
TD#5 = 94' - 0"
EXIT
#2
EXIT
#4
MEETING ROOM
MEETING ROOM
MEETING ROOM
MEETING ROOM
CORRIDOR
CO2
STORAGE
STAIRS
STAIRS
F E
C
BREAK ROOM
OA1
ELECTRICAL
ROOM
CP#3 = 48' - 0"
TYPE II(000)
CONSTRUCTION
ASSEMBLY OCCUPANCY
TYPE II(222)
CONSTRUCTION
BUSINESS OCCUPANCY
OFFICE
1B107I
OFFICE
1B107H
PRINTERS
1B107G
OFFICE
1B107F
OFFICE
1B107E
OFFICE
1B107D
CORRIDOR
C1B8
OFFICE
1B107J
SECRETARY
1B107K
ELECT.
1B107K
F E
OFFICE
1B107C
CORRIDOR
C1B7
OFFICE
1B107L
MECHANICAL
FEC
CP#4 = 66' - 0"
TD#6 = 43'- 0"
A TOTAL OF 73' - 0" TD TO EXIT #3
TD#7 = 86'- 0"
A TOTAL OF 168' - 0" TD TO EXIT #2
MECHANICAL
EXISTING WALL RATING:
2 HOUR FIRE BARRIER
SMOKE RESISTIVE HAZARDOUS
ROOM ENCLOSURE
FE EXISTING FIRE EXTINGUISHER
LIFE SAFETY LEGEND:
MEANS OF EGRESS:
TRAVEL DISTANCE
COMMON PATH
EXIT DISCHARGE
DEAD-END CORRIDOR
PROVIDED CLEAR DOOR WIDTH (INCHES)
MAX OCCUPANT LOAD CAPACITY (NO. OF PEOPLE)
DOOR TAG
WALL RATING:
1 HOUR FIRE BARRIER
1. SHEET SIZE FOR PROPER SCALE IS 30X42.
CONTRACTOR SHALL NOT SCALE DRAWINGS
BUT SHALL REQUEST DESIRED DIMENSIONS
FROM ARCHITECT.
2. SEE SHEET G-002 FOR GENERAL NOTES.
3. MECHANICAL AND ELECTRICAL ITEMS
SHOWN ON THE RCP DRAWINGS ARE FOR
REFERENCE ONLY. FINAL LOCATION OF
MECHANICAL AND ELECTRICAL FIXTURE
WILL NEED TO BE COORDINATED WITH
ARCHITECTURE AND INTERIORS.
4. REFER TO ELECTRICAL DRAWING FOR ALL
ELECTRICAL CEILING FIXTURE SYMBOLS.
NOT ALL ELECTRICAL SYMBOLS ARE
INDICATED IN THE REFLECTED CEILING
LEGEND.
5. ALL CEILING MOUNTED ITEMS SHALL BE
LOCATED IN THE CENTER OF THE ACOUSTIC
CEILING PANEL UNLESS NOTED
OTHERWISE.
BUILDING CODE SUMMARY
2021 INTERNATIONAL BUILDING CODE
2021 N.F.P.A. 101 LIFE SAFETY CODE
PROJECT NAME: EHRM TRAINING AND ADMIN SPACE
OKLAHOMA CITY VA HEALTH CARE SYSTEM
A/E PROJECT NO.: 2226.A32
PREPARED BY: KARL PERSON
DATE: 4-15-22
1. APPLICABLE CODES/STANDARDS:
A. VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATOIN GUIDE, AND OTHER GUIDENCE ON THE TECHNICAL INFORMATION
LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
a. ARCHITECTURAL (AUG. 2, 2014); ASBESTOS ABATEMENT (JULY 2011); ELECTRICAL (DEC 2015); FIRE PROTECTION (DEC 2016) HVAC (MAR 2011); INTERIOR DESIGN (MAY 2008); LIGHTING DESIGN (DEC 2015); PHYSICAL SECURITY (JAN 2015); PLUMBING (NOV 2014); SIGNAGE (OCT 2013)
b. PG-18-14 ROOM FINISH, DOOR HARDWARE SCHEDULE
c. PG-18-9 SPACE PLANNING CRITERIA –
B. INTERNATIONAL BUILDING CODE IBC (2021)
C. NFPA 1 –FIRE CODE (2021)
D. NFPA 101 -LIFE SAFETY CODE (LSC) –(2021)
E. NFPA 220 –STANDARDS ON TYPES OF BUILDING CONSTRUCTION –(2019)
F. NFPA 10 –STANDARD FOR PORTABLE FIRE EXTINGUISHERS –(2018)
G. NFPA 241 –STANDARD FOR SAFEGUARDING CONSTRUCTION (2018)
H. REFER TO FIRE PROTECTION/LIFE SAFETY/ACCESSIBILITY CODE REVIEW FOR ADDITIONAL CODES & STANDARDS.
2. OCCUPANCY CLASSIFICATION: NEW ASSEMBLY (L.C.S. CHAPTER.12)
3. TYPE OF CONSTRUCTION:
A. NFPA 220(TABLE 4.1.1) –TYPE II (000)
4. OCCUPANCY SEPARATIONS:
A. NFPA 101 CHAPTER 6
5. TYPE OF CONSTRUCTION -FIRE-RESISTIVE REQUIREMENTS (NFPA 220 TABLE 4.1.1)
A. EXTERIOR WALLS -BEARING = 0 HOURS
B. INTERIOR WALLS -BEARING = 0 HOURS
C. EXTERIOR WALLS -NON-BEARING = 0 HOURS
D. INTERIOR WALLS –NON-BEARING = 0 HOURS
E. STRUCTURAL FRAME = 0 HOURS
F. FLOORS/FLOOR-CEILINGS = 0 HOURS
G. ROOFS/ROOF-CEILING = 0 HOURS
6. FIRE-RESISTANT MATERIALS AND CONSTRUCTION (CHAPTER 7) (L.S.C. 8.2.3)
A. FIRE RESISTIVE ASSEMBLIES AS PER CHAPTER 7 –SMOKE PARTITIONS, IBC SECTION 710 (L.S.C. SECTION 8.4)
B. NFPA 101 -CHAPTER 18 HAZARDOUS ROOMS AND INCIDENTAL USE ROOM SEPARATION.
7. FIRE PROTECTION REQUIREMENTS:
A. THE BUILDING IS CURRENTLY FULLY SPRINKLERED WITH AN AUTOMATIC STANDPIPE SYSTEM AND WILL REMAIN SO UPON COMPLETION OF THE PROJECT.
B. FIRE EXTINGUISHERS WILL BE PROVIDED AS INDICATED ON LIFE SAFETY PLANS.
C. NFPA 101 (CHAPTER 8 AND 9)
1. 1-HR FIRE BARRIER REQUIRED FOR GENERAL STROAGE, BOILER, OR FURNACE ROOMS AND SHOPS THAT INCLUDE WOODWORKING OR PAINTING AREA, UNLESS AUTOMATIC SPRINKLER PROTECTION IS PROVIDED. WHERE AUTOMTIC SPRINKLER PROTECTION IS PROVIDED SMOKE PARTITIONS SHALL BE PROVIDED. 8.7.1.1, 8.7.1.2.
D. NFPA 10 (TABLE 6.2.1.1) –MECHANICAL ROOMS AND LARGE STORAGE ROOMS SHALL BE PROTECTED UTILIZING ORDINARY EXTINGUISHER PLACEMENT FOR CLASS A HAZARD.
A MAXIMUM TRAVEL DISTANCE TO FIRE EXTINGUISHER OF 75 FEET.
8. MEANS OF EGRESS/EXITING:
A. NUMBER OF MEANS OF EGRESS: THE EXISTING EGRESS CONDITIONS SHALL NOT BE CHANGED AS A RESULT OF THIS PROJECT.
B. ARRANGEMENT OF MEANS OF EGRESS: THE EXISTING EGRESS CONDITIONS SHALL NOT BE CHANGED AS A RESULT OF THIS PROJECT
C. COMMON PATH OF TRAVEL:
1. NFPA 101 (12.2.5.2) –MAX ALLOWED 75FT FOR AREAS SERVING LESS THAN 50 OCCUPANTS.
2. PROVIDED: COMMON PATH IS LESS THAN 75 FT.
D. TRAVEL DISTANCE TO EXITS:
1. NFPA 101 (12.2.6.2.2) –MAX ALLOWED 250FT FULLY SPRINKLERED.
a. TD-1 = 52' - 0"
b. TD-2 = 22' - 0"
c. TD-3 = 76' - 0"
d. TD-4 = 96' - 0"
e. TD-5 = 94' - 0"
f. TD-6 = 73' - 0"
g. TD-7 = 168' - 0"
G. MEANS OF EGRESS ILLUMINATION:
1. NFPA 101 (7.8) –REQUIRE BY CHAPTER 38, PROVIDE IN ACCORDANCE WITH 7.8
2. EMERGENCY LIGHTING –NFPA 101 (7.9) –REQUIRED BY CHAPTER 38, PROVIDE IN
ACCORDANCE WITH 7.9.
9. OCCUPANT LOAD:
A. NFPA 101 (TABLE 7.3.1.2)
1. BUSINESS USE: 150 SQ. FT. /PERSON
2. ASSEMBLY USE, LESS CONCENTRATED USE, WITHOUT FIXED SEATING: 15 SF/PERSON
B. OCCUPANT LOAD CALCULATIONS SEE CODE REVIEW PLAN FOR SCHEDULE.
EGRESS PATH
ID
COMMON PATH (FT.)
CP-1 75' - 0"
CP-2
TRAVEL DISTANCE (FT.)
MEANS OF EGRESS CALCULATIONS
EXIT
ID
EGRESS CAPACITY
FACTOR
#1 0.2
#2 0.2
OCCUPANCY LOAD
MAXIMUM CAPACITY
EXIT WIDTH CALCULATIONS
32"
62"
CLEAR
WIDTH
NOTE: EGRESS WIDTH CALCULATIONS BASED ON
INTERNATIONAL BUILDING CODE AND NFPA 101 - LIFE
SAFETY CODE, 2021 EDITION.
MAXIMUM ACTUAL MAXIMUM ACTUAL
CP-3
CP-4
TD-1
TD-2
TD-3
TD-4
TD-5
75' - 0"
75' - 0"
75' - 0"
250' - 0"
250' - 0"
250' - 0"
250' - 0"
46' - 6"
22' - 0"
76' - 0"
48' - 0"
66' - 6"
96' - 0"
94' - 0"
62' - 0"
52' - 0"
DEAD END CORRIDOR (FT.)
MAXIMUM ACTUAL
20' - 0" N/A
NOTE: MEANS OF EGRESS CALCULATIONS BASED ON INTERNATIONAL BUILDING CODE AND
NFPA 101- LIFE SAFETY CODE, 2021 EDITION.
250' - 0"
TD-6
TD-7
250' - 0" 73' - 0"
168' - 0"
-- 250' - 0"
#3 0.2 36072"
#4 0.2 16032"
20' - 0" N/A
20' - 0" N/A
20' - 0" N/A
20' - 0" N/A
20' - 0" N/A
20' - 0" N/A
20' - 0" N/A
20' - 0" N/A
20' - 0" N/A
20' - 0" N/A
PROJECT LOCATION
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA
57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COMFOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECTCONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of
Veterans Affairsof
/1
/2
:5
:2
P
M
CONSTRUCTION DOCUMENTS
05/12/2022
CODE REVIEW PLAN
G-011
EHRM TRAINING AND ADMIN
SPACE
JGCKP
921 NE 13TH ST
OKLAHOMA CITY, OK 73104Owner
VA259-16-D-0217
5 59
1/8" = 1'-0"
OCCUPANCY PLAN - LEVEL 1
1/8" = 1'-0"
OCCUPANCY PLAN - LEVEL 2
GENERAL NOTES:
TRUE
NORTH
N
TRUE
NORTH
N
1" = 100'-0"
KEY PLAN TRUE
NORTH
N
B
2 2
8 8
D
D
E
E
F
F
G
G
H
H
A3.00
A3.00
A3.00
A3.00
02-02 02-02 02-0202-02
02-0202-02
02-03 02-03
02-03
02-03
02-03 02-03
02-03
02-03
02-03
02-03
02-03
02-03
02-03
02-03 02-0302-03
02-03
02-03 02-03
02-15
02-15 02-15
02-15
02-1502-15
02-13 02-1302-12 02-12
02-03 02-03
02-03
02-0702-07
02-5002-50
02-2802-28
02-1402-14
02-06 02-06 02-06
02-17
02-22
02-17
02-52
02-52
02-52
02-52
02-52
02-52 02-52 02-52
02-52
02-52 02-52
02-23
02-23
FE
LIMITS OF PROJECT/CONSTRUCTION
UNDER THIS CONTRACT.
AREA OF WORK NOT IN THE SCOPE.
EXISTING TO REMAIN.
NEW PLAN AREA LEGEND:
1. SHEET SIZE FOR PROPER SCALE IS 30X42.
CONTRACTOR SHALL NOT SCALE DRAWINGS
BUT SHALL REQUEST DESIRED DIMENSIONS
FROM ARCHITECT.
2. SEE SHEET G-002 FOR GENERAL NOTES.
3. MECHANICAL AND ELECTRICAL ITEMS
SHOWN ON THE RCP DRAWINGS ARE FOR
REFERENCE ONLY. FINAL LOCATION OF
MECHANICAL AND ELECTRICAL FIXTURE
WILL NEED TO BE COORDINATED WITH
ARCHITECTURE AND INTERIORS.
4. REFER TO ELECTRICAL DRAWING FOR ALL
ELECTRICAL CEILING FIXTURE SYMBOLS.
NOT ALL ELECTRICAL SYMBOLS ARE
INDICATED IN THE REFLECTED CEILING
LEGEND.
5. ALL CEILING MOUNTED ITEMS SHALL BE
LOCATED IN THE CENTER OF THE ACOUSTIC
CEILING PANEL UNLESS NOTED
OTHERWISE.
1 1
10 10
B
B
2 2
8 8
D
D
E
E
F
F
G
G
H
H
A3.00
A3.00
A3.00
A3.00
A3.00
A3.00
02-02
02-02
02-02
02-03
02-03
02-03 02-03
02-03
02-02
02-03 02-03
02-03
02-03
02-12
02-12
02-0502-05
02-0502-05
02-0502-05
02-5002-50
02-2802-2802-02 02-03
02-18
4' - 4 7/8"
F E
02-24
EXISTING WALL RATING:
2 HOUR FIRE BARRIER
SMOKE RESISTIVE HAZARDOUS
ROOM ENCLOSURE
PROJECT LOCATION
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA
57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COMFOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECTCONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of
Veterans Affairsof
/1
/2
:5
:0
P
M
CONSTRUCTION DOCUMENTS
05/12/2022
DEMOLITION PLAN
AD1.00
EHRM TRAINING AND ADMIN
SPACE
JGCKP
921 NE 13TH ST
OKLAHOMA CITY, OK 73104Owner
VA259-16-D-0217
6 59
1/8" = 1'-0"
DEMOLITION PLAN - LEVEL 1
GENERAL NOTES:
KEYNOTES:
02-02 REMOVE EXISTING DOOR, DOOR
HARDWARE, AND FRAME COMPLETELY.
COORDINATE WITH ANY ASSOCIATED
ELECTRICAL/ACCESS CONTROL
DEMOLITION.
02-03 REMOVE EXISTING WALL FROM FINISH
FLOOR TO STRUCTURE ABOVE AND ANY
ASSOCIATED
MECHANICAL/PLUMBING/ELECTRICAL/FIRE
PROTECTION. SEE MECHANICAL,
PLUMBING, ELECTRICAL, FIRE
PROTECTION FOR ADDITIONAL
INFORMATION.
02-05 REMOVE EXISTING CONCRETE SLAB,
REFER TO STRUCTURAL DRAWINGS.
02-06 REMOVE CURTAIN, TRACK AND SLIDING
PANELS TO STRUCTURAL WALL.
02-07 REMOVE EXISTING FLOORING, BASE, TRIM,
TO ITS ENTIRETY AT THE FIRST FLOOR.
PREPARE FOR NEW FLOORING, SEE FLOOR
FINISH PLAN.
02-12 REMOVE EXISTING STAIRS AND RAILINGS
TO ITS ENTIRETY.
02-13 REMOVE EXISTING RAMP AND RAILINGS TO
ITS ENTIRETY.
02-14 PATCH/FILL ANY HOLES REMAINING AFTER
DEMOLITION TO CREATE A SMOOTH
FLOORING SUITABLE FOR STRUCTURAL
INTEGRITY AND FLOORING INSTALLATION.
02-15 REMOVE EXISTING PLUMBING FIXTURES
AND PIPING. SEE PLUMBING DRAWINGS
FOR ADDITIONAL INFORMATION.
02-17 LEAVE EXISTING WINDOW AND BLINDS,
FRAME AND DRYWALL OVER.
02-18 SAW OFF STRINGER TO BE FLUSH WITH
FLOOR, FILL IN FLOOR, SEE SHEET A1.00
DETAIL 3. REMOVE HANDRAIL FILL HOLES
AND PATCH WALLS AS REQUIRED.
02-22 REMOVE ALUMINUM STORE FRONT DOOR
AND GLASS, REPLACE WITH NEW.
02-23 CREATE TEMP VESTIBULE FOR
CONSTRUCTION TRAFFIC.
02-24 SEE SHEET MD 1.10 FOR REMOVING PAD
AT AHU.
02-28 GUT OUT FIRST AND SECOND LEVEL TO ITS
ENTIRETY, SEE MECHANICAL, PLUMBING,
STRUCTURAL, ELECTRICAL, FIRE
PROTECTION FOR ADDITIONAL
INFORMATION REGARDING DEMOLITION.
02-50 REMOVE EXISTING ACOUSTICAL CEILING
TILE, GRID, CEILING MOUNTED EQUIPMENT,
AND ANY ASSOCIATED MECHANICAL/
ELECTRICAL/ PLUNBING/ FIRE PROTECTION
FIXTURES. SEE MECHANICAL/ PLUMBING/
ELECTRICAL/ FIRE PROTECTION FOR
ADDITIONAL INFORMATION.
02-52 REMOVE ALL DRYWALL DOWN TO METAL
STUDS.
1/8" = 1'-0"
DEMOLITION PLAN - UPPER LEVEL
TRUE
NORTH
N
TRUE
NORTH
N
DEMO NOTE
1. SEE ADDITIONAL DEMOLITION REQUIREMENTS ON
SHEET A3.00.
TRUE
NORTH
N
1" = 100'-0"
KEY PLAN
SLOTTED SLIP TRACK
UNDERSIDE OF STRUCTURAL DECKING
METAL STUD FRAMING AT 16" O.C.
FLEXIBLE SEALANT, EACH SIDE
SEE WALL TYPE
DEFLECTION GAP3
/4
SAFING INSULATION
ANCHOR STUD TO SLIP
TRACK WITH WAFER HEAD
SCREW
20 GA 3" STEEL
STRAP AT 16" O.C. WHERE
REQUIRED
/4
STRUCTURAL DECK-PROVIDE
INFILL TO DECK
SLOTTED SLIP TRACK
SAFING INSULATION
ANCHOR STUD TO SLIP TRACK
WITH WAFER HEAD
SCREEN
/2
/4
ATTACH 8" GYPSUM BOARD WITH
SCREW ANCHOR
/4
GYPSUM BOARD
DEFLECTION GAP DEFLECTION GAP
DECKING CHANNEL DEPTH
METAL DECK
(PERPENDICULAR TO FLUTES)
METAL DECK
(PARALLEL TO FLUTES)
STEEL BEAM
DETAIL 1C - "OTHER WALLS" - ADDITIONAL NOTES:
1. UPGRADE TO DETAIL "1A" WHERE WALL IS DESIGNED WITH A FIRE-RESISTANCE RATING.
2. UPGRADE TO DETAIL "1B" WHERE WALL IS DESIGNED AS A "SMOKE PARTITION" OR "SOUND-CONTROL" WALL.
SLOTTED TOP TRACK
STUD
PDF 0.145 INCH X 1 1/4" HILTI
X-DN1 ESR-1663 AT 16" O.C.
PDF 0.145 INCH X 1 1/4" HILTI
X-DN1 ESR-1663 AT 16" O.C.
#8 SMS MID HEIGHT OF
SLOT TYP
2"X20 GAUGE STRAPS AT
16" O.C.
#8 SMS MIDDLE HEIGHT OF
SLOT TYPICAL
SLOTTED TOP TRACK
STUD
18 GAUGE METAL Z-BAR AT 16" O.C.,
ATTACH TO STEEL BEAM WITH (2) MINIMUM
1/8" PDF, 1/2" MINIMUM EMBEDMENT
#8 SMS MIDDLE HEIGHT OF
SLOT TYP
/8
1" 1" 5 /8
/8
METAL DECK
(PERPENDICULAR TO FLUTES)
CUT ONE LAYER GWB TO
FOLLOW PROFILE OF
DECKING. SEAL
CONTINUOUSLY WITH
ACOUSTICAL SEALENT.
SLOTTED TOP TRACK
STUD
SAB
GWB
PDF 0.145 INCH X 1 1/4" HILTI
X-DN1 ESR-1663 AT 16" O.C.
#8 SMS MID HEIGHT OF
SLOT TYP.
FILL FLUTE VOID W/ SAB
PDF 0.145 INCH X 1 1/4" HILTI
X-DN1 ESR-1663 AT 16" O.C.
GWB SOUND AND
SMOKE CLOSURE
STRIP SECURE TO
STRUCTURE AND
SEAL WITH
ACOUSTICAL
SEALENT
2"X20 GA STRAPS AT
16" O.C.
ACOUSTICAL SEALENT
(BOTH SIDES)
#8 SMS MID HEIGHT OF
SLOT TYP
SLOTTED TOP TRACK
STUD
SAB
GWB
18GA MET Z-BAR AT 16" O.C.,
ATTACH TO STL BEAM W/(2) MIN
1/8" PDF, 1/2" MIN EMBEDMENT
ACOUSTICAL SEALENT
(BOTH SIDES)
#8 SMS MID HEIGHT OF
SLOT TYP
METAL DECK
(PARALLEL TO FLUTES)
STEEL BEAM
/8
/8
1" 1"
/8
DETAIL 1B - "SMOKE PARTITIONS AND SOUND-CONTROL WALLS" - ADDITIONAL NOTES:
1. UPGRADE TO DETAIL "1A" WHERE WALL IS DESIGNATED WITH A FIRE-RESISTANCE RATING.
2. FILL VOIDS WITH SOUND ATTENUATION BATTS (SAB).
3. SOUND WALLS AND SMOKE PARTITIONS REQUIRE THAT AT LEAST ONE LAYER OF GWB BE CUT TO FOLLOW UNDULATING SURFACES OF SUPERSTRUCTURES INCLUDING BUT NOT LIMITED TO FLUTES METAL DECKING. JOINT GWB TO SUPERSTRUCTURE WITH A CONTINUOUS BEAD OF ACOUSTICAL SEALANT.
4. BUILDING CODE REQUIRES THAT "SMOKE PARTITIONS" BE SEALED TO STRUCTURE AS INDICATED TO SUCCESSFULLY "...LIMIT THE PASSAGE OF SMOKE...".
SLOTTED TOP TRACK
1 OR 2 LAYERS OF
GYPSUM WALLBOARD; SEE
WALL TYPE
STUD
SAB
MINERAL WOOL
FORMING
MATERIAL
PDF 0.145 INCH X 1
1/4" HILTI X-DN1
ESR-1663 AT 16" O.C.
/8
/8
1" 1"
FIRE STOP JOINT SPRAY
#8 SMS MIDDLE HEIGHT OF
SLOT TYPICAL
PDF 0.145 INCH X 1 1/4" HILTI
X-DN1 ESR-1663 AT 16" O.C.
/8
"2"X20 GAUGE STRAPS AT
16" O.C.
FIRE STOP JOINT SPRAY
#8 SMS MIDDLE HEIGHT OF
SLOT TYPICAL
SLOTTED TOP TRACK
1 OR 2 LAYERS OF
GYPSUM WALLBOARD;
SEE WALL TYPE
STUD
SAB
#8 SMS MIDDLE HEIGHT OF
SLOT TYPICAL
18 GAUGE METAL Z-BAR AT 16" O.C.,
ATTACH TO STEEL BEAM WITH (2) MINIMUM
1/8" PDF, 1/2" MINIMUM EMBEDMENT
MINERAL WOOL FORMING
MATERIAL
DESIGN BASIS: UL-HW-D-0042
METAL DECK
(PERPENDICULAR TO FLUTES)
DESIGN BASIS: UL-HW-D-0264
METAL DECK
(PARALLEL TO FLUTES)
DESIGN BASIS: UL-HW-D-0259
STEEL BEAM
DETAIL 1A- "FIRE-RATED WALLS"- ADDITIONAL NOTES:
1. CONDITIONS INDICATED TO SHOW DESIGN INTENT. THEY ARE NOT INTENDED TO BE PROPRIETARY. CONTRACTOR MAY EMPLOY SIMILAR A UL-APPROVED TOP-OF-WALL DESIGNS THAT ARE APPROPRIATE FOR CONDITIONS.
2. REFER TO SECTION 07270 / FIRESTOPPING FOR ADDITIONAL REQUIREMENTS REGARDING HEAD-OF-WALL CONDITION FOR FIRE-RATED WALLS.
GENERAL NOTES
1. CONDITIONS INDICATED SHOW DESIGN INTENT, ESPECIALLY IN REGARD TO ACCOMMODATION OF STRUCTURAL DEFLECTION AND CONTINUITY OF INTEGRITY OF SOUND, SMOKE AND FIRE WALLS.
2. DESIGN INTENT DETAILS ARE NOT INTENDED TO BE PROPRIETARY. CONTRACTOR MAY EMPLOY SIMILAR HEAD-OF-WALL DESIGNS AND COMPONENTS AS APPROPRIATE FOR CONDITIONS.
3. DESIGN INTENT DETAILS MAY NOT SHOW ALL CONDITIONS TO BE ENCOUNTERED ON A PROJECT. COMPLY WITH MANUFACTURER AND UL APPROVED METHODS FOR ATYPICAL CONDITIONS.
4. SECURE TOP OF INTERIOR PARTITIONS TO SUPERSTRUCTURE IN A WAY THAT PROVIDES LATERAL STABILITY (PERPENDICULAR-TO AND IN-PLANE WITH WALL) YET ALLOWING FOR A MINIMUM OF 3/4" OF
VERTICAL DEFLECTION OF THE SUPERSTRUCTURE.
5. RIGIDLY SECURE SLOTTED TOP TRACK TO BUILDING SUPERSTRUCTURE IN AN APPROVED MANNER. EMPLOY Z-BARS, COLD-ROLLED CHANNELS OR SIMILAR SPACERS TO ACCOMMODATE THICKNESS OF
SPRAY-APPLIED FIRE-RESISTIVE MATERIALS (SFRM).
6. SLOTTED TOP TRACK, INDICATED ON THESE DETAILS, IS THE BASIS FOR DESIGN AND REFERS TO DEEP-LEG TRACKS WITH VERTICALLY SLOTTED HOLES. OPTIONAL MANUFACTURERS MAY PROVIDE
SIMILAR, PROPRIETARY METHODS IN ACCORDANCE WITH THE PROVISIONS OF SPECIFICATION SECTION 09 22 16.
7. SECURE VERTICAL STUDS TO SLOTTEDTOP TRACK AT MID-HEIGHT OF VERTICAL SLOTS IN TRACK. COMPONENTS INTENDED TO SLIDE VERTICALLY AS SUPERSTRUCTURE DEFLECTS.
8. DO NOT SCREW GYPSUM WALLBOARD TO TOP TRACK OR SUPERSTRUCTURE. GWB SCREWS INTO THE STUDS MUST BE AT LEAST 1" BELOW THE BOTTOM OF THE TOP TRACK\
9. REFER TO PARTITION STANDARDS FOR SPECIFIC WALL TYPES.
10. AT FIRE-RATED WALLS REFER TO SPECIFICATION SECTION 07 84 00 FOR ADDITIONAL REQUIREMENTS REGARDING HEAD-OF-WALL CONDITIONS.
11. MAINTAIN ACOUSTIC RATING WHERE SOUND-CONTROL WALLS ARE INDICATED.
12. FIRE STOPPING AND ACOUSTICAL SEALANTS SHALL AUTOBOND. PROVIDE EXPOSED CLEAN SEALANT (TO CONCEAL FIRESTOPPING) AT FOOD SERVICE, FDA INSPECTED PRODUCTION FACILITIES, VIVARIA, BIOLOGICAL CONTAINMENT AND CLEAN ROOM APPLICATIONS.
13. WHERE A WALL IS DESIGNATED AS BOTH A SOUND-CONTROL WALL AND A FIRE-RATED WALL, REFER TO FIRE-RATED HEAD-OF-WALL CONDITIONS.
14. WHERE A WALL IS DESIGNATED AS A SOUND-CONTROL WALL, FILL ALL VOIDS WITH SOUND ATTENUATION BATTS (SAB)
15. SMOKE PARTITIONS REQUIRE THAT AT LEAST ONE LAYER OF GWB, AND SOUND-CONTROL WALLS REQUIRE GWB ON BOTH SIDES, BE CUT TO FOLLOW UNDULATING SURFACES OF THE
SUPERSTRUCTURE INCLUDE, BUT NOT LIMITED TO, FLUTES IN METAL DECKING. PROVIDE A CONTINUOUS BEAD OF SEALANT (AS SPECIFIED) TO SUPERSTRUCTURE.
SLOTTED DEEP LEG
DEFLECTION TRACK
SLIP
CONNECTION
VERTICAL STUD
ISOMETRIC VIEW OF SLOTTED TOP TRACK
T Y
P
FINISH CEILING WHERE OCCURRING,
(SEE REFLECTED CEILING PLAN)
METAL STUD TRACK TO CONCEAL
SOUND INSULATION (WHERE OCCURRING)
SEE RCP
3 5/8" x 20GA METAL STUD BRACES
AT 48" O.C. ALTERNATE DIRECTIONS
FASTEN ENDS W/ (2) #10 SMS.
METAL STUD ATTACHED TO DECK
ALTERNATE
BRACE BEYOND
1. SHEET SIZE FOR PROPER SCALE IS 30X42.
CONTRACTOR SHALL NOT SCALE DRAWINGS
BUT SHALL REQUEST DESIRED DIMENSIONS
FROM ARCHITECT.
2. SEE SHEET G-002 FOR GENERAL NOTES.
3. MECHANICAL AND ELECTRICAL ITEMS
SHOWN ON THE RCP DRAWINGS ARE FOR
REFERENCE ONLY. FINAL LOCATION OF
MECHANICAL AND ELECTRICAL FIXTURE
WILL NEED TO BE COORDINATED WITH
ARCHITECTURE AND INTERIORS.
4. REFER TO ELECTRICAL DRAWING FOR ALL
ELECTRICAL CEILING FIXTURE SYMBOLS.
NOT ALL ELECTRICAL SYMBOLS ARE
INDICATED IN THE REFLECTED CEILING
LEGEND.
5. ALL CEILING MOUNTED ITEMS SHALL BE
LOCATED IN THE CENTER OF THE ACOUSTIC
CEILING PANEL UNLESS NOTED
OTHERWISE.
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA
57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COMFOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECTCONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of
Veterans Affairsof
/1
/2
:5
:2
P
M
CONSTRUCTION DOCUMENTS
05/12/2022
HEAD OF WALL DETAILS
A0.01
EHRM TRAINING AND ADMIN
SPACE
JGCKP
921 NE 13TH ST
OKLAHOMA CITY, OK 73104Owner
VA259-16-D-0217
7 59
3" = 1'-0"
DEFLECTION DETAIL-PARALLEL TO DECK
3" = 1'-0"
DEFLECTION DETAIL-PERPENDICULAR TO DECK
1" = 1'-0"
HEAD-OF-WALL CONDITIONS - STUD WALLS - NON-FIRE, NON-SMOKE, NON-SOUND CONTROL
WALLS
1" = 1'-0"
HEAD-OF-WALL CONDITIONS - STUD WALLS - SMOKE PARTITIONS AND SOUND CONTROL WALLS
1" = 1'-0"
HEAD-OF-WALL CONDITIONS - STUD WALLS - FIRE RATED WALLS
3/4" = 1'-0"
GENERAL REQUIREMENTS FOR STUD PARTITIONS
3" = 1'-0"
TYPICAL PARTITION KICKER
GENERAL NOTES:
20 GAUGE MINIMUM METAL SILL
TRACK BELOW
DOUBLE 20 GAUGE MTL
STUDS
20 GAUGE MINIMUM METAL TRACK
AT FLOOR
1" X 20 GAUGE METAL STRAP
PLATES AT 3'-6" OC EACH
SIDE
CLIP ANGLE
1" X 20 GAUGE METAL
STRAP AT 3'-6" O.C.,
EACH SIDE
DOUBLE 20 GAUGE
METAL STUDS AT
BOTH JAMBS
20 GAUGE MINIMUM
METAL TRACK
AT FLOOR
GENERAL NOTES:
1. CONTRACTOR SHALL
COORDINATE LOCATIONS
OF HORIZONTAL
FASTENERS. PLAN
WALL FINISH
VERTICAL WALL STUDS
AT 16" [406mm] OR 24" [610mm] O.C.
CUT HORIZONTAL
FASTENER FROM
STUD
FASTEN AT BOTH ENDS
WITH MINIMUM 4 TAPPING
SCREWS.
TYPE C
14 GAUGE STEEL RUNNER TRACK-
CLIP FLANGES AND FOLD
WEB TO FORM
ATTACHMENT FLANGE
MIN 20 GAUGE METAL STUDS
FACING OPPOSITE
DIRECTIONS TO ALLOW
MOUNTING PLATE
ATTACHMENT
8" MINIMUM, DEEPER IF
REQUIRED
6" MINIMUM, DEEPER IF
REQUIRED
TYPE B
20 GAUGE METAL RUNNER
TRACK - CLIP FLANGES
TO FIT OVER STUDS
CONT16 GAUGE 6" WIDE
METAL BACK-UP STRAP
TYPE A
M O
U N
T I N
G H
E
IG
H T
S
R E
F E
R E
N C
E T
Y P
IC
A
L M
O U
N T
I N G
H E
IG
H
T S
R E
F E
R E
N C
E T
Y P
IC
A
L M
O U
N T
I N G
H E
IG
H
T S
R E
F E
R E
N C
E T
Y P
IC
A
L
ADDITIONAL NOTES: 1/2" MAX
1/2" MAX
1. BUILDING CODE REQUIRES THAT "SMOKE PARTITIONS" BE SEALED
TO STRUCTURE AS INDICATED TO SUCCESSFULLY "LIMIT THE PASSAGE
OF SMOKE".
2. CONDITIONS INDICATED TO SHOW DESIGN INTENT, AND NOT
INTENDED TO BE PROPRIETARY. CONTRACTOR MAY EMPLOY SIMILAR
UL-APPROVED CONTROL JOINTS DESIGNS THAT ARE APPROPRIATE
FOR THE SPECIFIC CONDITION. JOINTS TO BE SIZED TO
ACCOMMODATE MOVEMENT CAPABILITIES OF FIRESTOP ASSEMBLY.
1/2" MAX
CONTROL JOINT,
BOTH SIDES
1 1/2"
CONTROL JOINT,
BOTH SIDES
1HOUR FIRE RATED
WHI-647-3024
2 LAYERS OF 5/8"
GYPSUM WALLBOARD
PARTITION AS
SCHEDULED PARTITION AS
SCHEDULED
MAX
24'-0”
MAX
24'-0” 24'-0”
MAX
1 1/2"
CONTROL JOINT,
BOTH SIDES
2HOUR FIRE RATED
WHI-651-0318.1
2 LAYERS OF 5/8" GYPSUM
WALLBOARD
PARTITION AS
SCHEDULED
SOUND ATTENUATION
BLANKET COMPRESSED TO
FILL OPENING AT SOUND
RATED PARTITION
MAX
24'-0”
MAX
24'-0”
CONCRETE, MASONRY OR
STEEL CHANGE IN
CONSTRUCTION
1/2" MAX
CHANGE IN
CONSTRUCTION
PARTITION AS
SCHEDULED
1/2" MAX
LC-BEAD
SEALANT, REFERENCE
SPECS FOR TYPE
MAX
24'-0”
MAX
24'-0”
CONTROL JOINT
1/2" MAX
L-BEAD
SEALANT BOTH SIDE,
PARTITION AS
SCHEDULED GYPSUM WALLBOARD
SUSPENDED
CEILING SYSTEM
REFERENCE SPECS FOR TYPE
/4
ACOUSTIC BATT INSULATION (WHERE
OCCURRING)
METAL STUD TRACK; MATCH GAUGE AND SIZE
TO STUD.
BASE, SEE FINISH SCHEDULE
SEALANT AND BACKER ROD, EACH SIDE
NOTE: PROVIDE CONTINUOUS SMOKE SEALANT AT
SMOKE PARTITIONS.
PARTITION AS SCHEDULED.
INSTALL GWPS A
MINIMUM OF 1/4" ABOVE
SUB FLOOR.
DOOR, SEE SCHEDULE
HOLLOW METAL FRAME
SEALANT AT FRAME PERIMETER,
EACH SIDE
METAL STUD WALL, SEE WALL
TYPES
5/8" GYPSUM BOARD
T Y
P
ADJACENT WALL
S E
E W
A L L
T Y
P E
SEE WALL TYPE
20 GAUGE MINIMUM
METAL TRACK
CLIP ANGLE
FINE, NEAT SEALANT BEAD AT PERIMETER.
FIRE EXTINGUISHER CABINET, VERIFY DIMENSIONS WITH MFR.
NOTE:
INSTALL PER MANUFACTURER'S REQUIREMENTS.
PARTITION AS SCHEDULED, SEE LIFE SAFETY PLAN FOR RATED PARTITIONS.
METAL STUD OR WOOD
BLOCKING FOR WALL MOUNTED
ITEMS SUCH AS CABINETS, TELEVISION
BRACKETS, COUNTERS, WHITE BOARDS,
AND SIMILAR ITEMS. COORDINATE
REQUIREMENTS WITH ITEM TO BE MOUNTED
2" WIDE 20 GAUGE
METAL STRAP
20 GAUGE METAL TOP TRACK
(TYPICAL UNLESS NOTED
OTHERWISE)
ABOVE CEILING
OPENING
PROVIDE DIAGONAL BRACING (AT
45° TYPICAL) OF TOP TRACK AT 48°
O.C. MAX BETWEEN FULL HEIGHT
STUDS
UNDERSIDE OF SLAB,
FLOOR OR ROOF DECK
CEILING LINE
OPENING ABOVE CEILING
WHICH INTERRUPTS LOWER
OPENING JAMB STUDS.
DOUBLE STUDS
DOOR
OPENING
25 GAUGE MINIMUM
BOTTOM TRACK (TYPICAL)
FLOOR LINE
LARGE BELOW
CEILING OPENING
BELOW
CEILING
OPENING
DOUBLE DOOR OPENING
DOOR
OPENING
DOOR
OPENING
NOTES:
1. ALL STUDS ARE SPACED 16" OC MAXIMUM.
2. ALL STUDS SHALL BE "C" STUDS WITH 1/4"
RETURN FLANGE MINIMUM.
3. INDICATES SHELVING OR
CABINETRY.
4. DOUBLE STUDS AT SIDES OF OPENING
SHALL NOT BE CUT FOR DUCT WORK OR
ANY OTHER MECHANICAL SYSTEMS.
5. REFER TO INTERIOR SHEET FOR
MOUNTING TYPE DETAILS.
6. PROVIDE PARTITION BRACING AT ALL
ASSEMBLIES OVER 16'-0" IN HEIGHT,
UNLESS NOTED OTHERWISE.
MOUNTING DETAIL
TYPE B
20 GAUGE MINIMUM STUDS
AT WALL MOUNTED
ARCHITECTURAL
CABINETS/MILLWORK/
ATTACHED SHELVING.
DOUBLE
STUDS
4' 6" MAX
DOUBLE STUDS
8' 6" MAX 4' 6" MAX 8' 6" MAX
ALL STUDS ARE TO BE 20 GAUGE
IF GREATER THAN 8' 6"
8' 6" MAX 4' 6" MAX
8' 6" MAX
LARGE ABOVE CEILING
OPENING
TOP TRACK
A0.02
A0.02
A0.02 4
A0.02
A0.02
A0.02
A0.02
A0.02
1. SHEET SIZE FOR PROPER SCALE IS 30X42.
CONTRACTOR SHALL NOT SCALE DRAWINGS
BUT SHALL REQUEST DESIRED DIMENSIONS
FROM ARCHITECT.
2. SEE SHEET G-002 FOR GENERAL NOTES.
3. MECHANICAL AND ELECTRICAL ITEMS
SHOWN ON THE RCP DRAWINGS ARE FOR
REFERENCE ONLY. FINAL LOCATION OF
MECHANICAL AND ELECTRICAL FIXTURE
WILL NEED TO BE COORDINATED WITH
ARCHITECTURE AND INTERIORS.
4. REFER TO ELECTRICAL DRAWING FOR ALL
ELECTRICAL CEILING FIXTURE SYMBOLS.
NOT ALL ELECTRICAL SYMBOLS ARE
INDICATED IN THE REFLECTED CEILING
LEGEND.
5. ALL CEILING MOUNTED ITEMS SHALL BE
LOCATED IN THE CENTER OF THE ACOUSTIC
CEILING PANEL UNLESS NOTED
OTHERWISE.
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA
57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COMFOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECTCONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of
Veterans Affairsof
/1
/2
:5
:2
P
M
CONSTRUCTION DOCUMENTS
05/12/2022
PARTITION FRAMING DETAILS
A0.02
EHRM TRAINING AND ADMIN
SPACE
JGCKP
921 NE 13TH ST
OKLAHOMA CITY, OK 73104Owner
VA259-16-D-0217
8 59
3" = 1'-0"
SMOKE PARTITION-WALL BASE DETAIL
3" = 1'-0"
DOOR DETAIL TYPICAL
1" = 1'-0"
LARGE OPENING JAMB STUDS
1" = 1'-0"
DOOR OPENING JAMB STUDS
1" = 1'-0"
OPENING HEADER
3" = 1'-0"
FIRE EXTINGUISHER CABINET AT METAL STUD
1" = 1'-0"
DETAIL - ANCHORAGE - GRAB BARS AND CABINETS
1" = 1'-0"
METAL BACKING DETAILS FOR ACCESSORIES AND EQUIPMENT
1" = 1'-0"
GYPSUM WALLBOARD CONTROL JOINT DETAILS
1/4" = 1'-0"
FRAMING ELEVATION
1/4" = 1'-0"
TYPICAL INTERIOR PARTITION FRAMING
DN
UP
DN
DN
5 5
B
B
2 2
8 8
D
D
E
E
F
F
G
G
H
H
A3.00
A3.00
A3.00
A3.00
MEETING ROOM
MEETING ROOM
STORAGE
5 STORAGE
TOILET
TOILET
TOILET
TOILET
BREAK ROOM
OA1
OFFICE
OA2
OPEN OFFICE
OA3
STORAGE
OA4
OFFICE
OA5
OPEN OFFICE
OA6
A3.00
A3.00
CORRIDOR
CO1
HAC
3 4 7 8
A5.02
TOILET FEMALE
GB112
VOLUNTEER
INFORMATION
GB113
F E
C
100' - 0"
LEVEL 1
102' - 11"
LEVEL 1.1
A4.01
A4.01
VOLUNTEER
SERVICE
GD107
ROOM
GD101
E L
E C
G D
CHIEF
VOLUNTEER
SERVICE
GD108
CORRIDOR
CG-2D
CORRIDOR
CG-1D
VESTIBULE
CG-1R
C O
R R
ID
O
R
C G
-2 R
PHYSICAL REHAB
GR119
STORAGE
GR100
ROOM
GR101
ROOM
GR102
CORRIDOR
CG-5R
FE
FE
FE
F E
C
FEC
10-02
10-03
O A
OA4
1 1
10 10
B
2 2
8 8
D
D
E
E
F
F
G
G
H
H
MEETING ROOM
MEETING ROOM
MEETING ROOM
MEETING ROOM
A3.00
A3.00
A3.00
A3.00
10 11
CORRIDOR
CO2
A3.00
A3.00
16 17
STORAGE
STAIRS
STAIRS
BREAK ROOM
OA1
ELECTRICAL
ROOM
111' - 0"
LEVEL 2
114' - 7"
LEVEL 2.1
OFFICE
1B107I
OFFICE
1B107H
PRINTERS
1B107G
OFFICE
1B107F
OFFICE
1B107E
OFFICE
1B107D
OFFICE
1B107J
SECRETARY
1B107K
CORRIDOR
C1B8
ELECT.
1B107K
OFFICE
1B107C
OFFICE
1B107L
CORRIDOR
C1B7
MECHANICAL
F E
C
F E
FEC
MECHANICAL
A1.00
23-01
LIMITS OF PROJECT/CONSTRUCTION
UNDER THIS CONTRACT.
AREA OF WORK NOT IN THE SCOPE.
EXISTING TO REMAIN.
NEW PLAN AREA LEGEND:
1. SHEET SIZE FOR PROPER SCALE IS 30X42.
CONTRACTOR SHALL NOT SCALE DRAWINGS
BUT SHALL REQUEST DESIRED DIMENSIONS
FROM ARCHITECT.
2. SEE SHEET G-002 FOR GENERAL NOTES.
3. MECHANICAL AND ELECTRICAL ITEMS
SHOWN ON THE RCP DRAWINGS ARE FOR
REFERENCE ONLY. FINAL LOCATION OF
MECHANICAL AND ELECTRICAL FIXTURE
WILL NEED TO BE COORDINATED WITH
ARCHITECTURE AND INTERIORS.
4. REFER TO ELECTRICAL DRAWING FOR ALL
ELECTRICAL CEILING FIXTURE SYMBOLS.
NOT ALL ELECTRICAL SYMBOLS ARE
INDICATED IN THE REFLECTED CEILING
LEGEND.
5. ALL CEILING MOUNTED ITEMS SHALL BE
LOCATED IN THE CENTER OF THE ACOUSTIC
CEILING PANEL UNLESS NOTED
OTHERWISE.
EXISTING WALL RATING:
2 HOUR FIRE BARRIER
SMOKE RESISTIVE HAZARDOUS
ROOM ENCLOSURE
WALL RATING:
1 HOUR FIRE BARRIER
PROJECT LOCATION
TOC
HSS 4"x2"x1/4" CONT. BRG. PL, SHIM AS REQ'D FOR 5" TOTAL
SLAB DEPTH
5" CONC. SLAB ON 1.5 VLI. 20 GA
GALV. COMP. FORM DECK w/
#3 REBAR @ 12" O.C. EA. WAY
(CENTERED)
EXISTING FLOOR AND STAIRCASE
@ MECHANICAL ROOM
3625162-43 MTL STUDS @ 12" O.C., TYP
(3) SIDES
362T125-54 CONT.
MTL. TOP AND BTM TRACK
w/ HILTI X-U PAF @ 16" O.C. (MAX)
L 5"x3"x1/4" CONT.
DECK EDGE ANGLE,
(TYP (3) SIDES) FASTEN
TO TRACK w/ HILTI X-U
PAF @ 16" O.C.
3/16" 3-12
1/2" ISOLATION JOINT & CAULK
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA
57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COMFOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECTCONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
Department of
Veterans Affairsof
/1
/2
:5
:3
P
M
CONSTRUCTION DOCUMENTS
05/12/2022
NEW FLOOR PLANS
A1.00
EHRM TRAINING AND ADMIN
SPACE
JGCKP
921 NE 13TH ST
OKLAHOMA CITY, OK 73104Owner
VA259-16-D-0217
9 59
1/8" = 1'-0"
FLOOR PLAN - LEVEL 1
1/8" = 1'-0"
FLOOR PLAN - LEVEL 2
GENERAL NOTES:
TRUE
NORTH
N
TRUE
NORTH
N
KEYNOTES:
10-02 EXISTING HANDRAIL TO REMAIN AND BE RE-PAINTED.
10-03 REINSTALL EXISTING HANDRAIL AND BE RE-PAINTED.
23-01 SEE SHEET MH 1.10 FOR ADDING PAD FOR AHU.
COORDINATE WITH MECHANICAL.
TRUE
NORTH
N
1" = 100'-0"
KEY PLAN
3/4" = 1'-0"
MECHANICAL STAIR INFILL
DN
UP
DN
DN
DN
1. SHEET SIZE FOR PROPER SCALE IS 30X42.
CONTRACTOR SHALL NOT SCALE DRAWINGS
BUT SHALL REQUEST DESIRED DIMENSIONS
FROM ARCHITECT.
2. SEE SHEET G-002 FOR GENERAL NOTES.
3. MECHANICAL AND ELECTRICAL ITEMS
SHOWN ON THE RCP DRAWINGS ARE FOR
REFERENCE ONLY. FINAL LOCATION OF
MECHANICAL AND ELECTRICAL FIXTURE
WILL NEED TO BE COORDINATED WITH
ARCHITECTURE AND INTERIORS.
4. REFER TO ELECTRICAL DRAWING FOR ALL
ELECTRICAL CEILING FIXTURE SYMBOLS.
NOT ALL ELECTRICAL SYMBOLS ARE
INDICATED IN THE REFLECTED CEILING
LEGEND.
5. ALL CEILING MOUNTED ITEMS SHALL BE
LOCATED IN THE CENTER OF THE ACOUSTIC
CEILING PANEL UNLESS NOTED
OTHERWISE.
MEETING ROOM
MEETING ROOM
STORAGE
STORAGE
TOILET
TOILET
TOILET
TOILET
BREAK ROOM
OA1
OFFICE
OA2
OPEN OFFICE
OA3
STORAGE
OA4
OFFICE
OA5
OPEN OFFICE
OA6
CORRIDOR
CO1
HAC
3 4 7 8
95 6' - 3" 4' - 0"
M3A
M3A M3A M3A M3A
M3A
M3E M3B
M3B
M3E
M3B
M3E
M3B
M3E M3E
M3B M3B
M3B M3B M3B
M3B
M3BM3B
66' - 10 3/4"
10' - 4 5/8"
/8
/4
10' - 4 5/8"
/4 "5
/8
/4
15' - 0 1/8" 17' - 4 7/8" 8' - 1 1/4" 10' - 4 5/8" 2' - 11 3/4"
12' - 4 7/8"
5' - 10 1/4" 4' - 4"
/4
O A
FE
FE
FE
F E
C
FEC
20' - 8 1/2" 4' - 8 1/2" 20' - 8 1/2"
M3E M3E
M3E M3E
E1
E1
E1
E1
E1
E1
E1 E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1E1
/8
A5.02
Sim
/8
MEETING ROOM
MEETING ROOM
MEETING ROOM
MEETING ROOM
10 11
CORRIDOR
CO2
4' - 10" 4' - 10"
16 17
STORAGE
4' - 10 1/8" 28' - 6 3/8" 29' - 3 1/2" 4' - 1"
4' - 11 1/4" 23' - 3…