This document contains an asbestos bulk analysis report and information on a related federal contract opportunity to repair the roof of Hangar H40 at Joint Base San Antonio Randolph in Texas. The asbestos bulk analysis report provides results of laboratory testing on five samples taken from the damaged roof, with none found to contain asbestos. The related federal contract opportunity is solicitation number FA301620R0045 to repair the hangar roof, with an amendment date of 03. The opportunity is with the Department of the Air Force Air Education and Training Command to provide repair services for the damaged roof at the specified location. The report and solicitation provide relevant details to inform potential contractors of the project scope and asbestos testing results prior to responding to the opportunity.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Bulk Analysis Report
Client:
Report Number:
Project/Test Address:
Client Number:
Reported Date:
Received Date:
Analyzed Date:
United States Air Force Base 06/25/2019
45-6537
06/25/2019
19-06-04022
7469 Whitepine Rd
Telephone: 800.347.4010
Richmond, VA 23237
Environmental Hazards Services, L.L.C.
H40_Damaged Roof; JBSA Randolph, TX
Laboratory Results Fax Number:
210-652-3685
502 CES/CEIE 1651 5th St., West JBSA Randolph, TX 78150
06/25/2019
Layer Type AsbestosClient Sample Number
Other Materials
Lab Gross DescriptionLab Sample Number
Black Tar-Like;
Brown/Black Fibrous;
Inhomogeneous
19-06-04022-001 40-RFROLL-
001-B-001
10% Cellulose 15% Fibrous Glass 75% Non-Fibrous
NAD
Brown Fibrous;
Homogeneous
19-06-04022-002 40-RFINS-001-
B-002
95% Cellulose 5% Non-Fibrous
NAD
Black Tar-Like; Fibrous;
Inhomogeneous
19-06-04022-003 40-RFROLL-
001-B-003
15% Fibrous Glass 85% Non-Fibrous
NAD
Black Tar-Like; Fibrous;
Red Aggregate;
Inhomogeneous
19-06-04022-004 40-RFROLL-
001-B-004
15% Fibrous Glass 85% Non-Fibrous
NAD
Black Tar-Like; Fibrous;
Red Aggregate;
Inhomogeneous
19-06-04022-005 40-RFROLL-
001-B-005
15% Fibrous Glass 85% Non-Fibrous
NAD
1 of 2Page
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:45-6537 19-06-04022
H40_Damaged Roof; JBSA Randolph, TX
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
Tasha Eaddy
1% Asbestos
Analyst:
Reporting Limit:
Method:
QC Blank:
QC Sample:
Araceli Enzler
EPA Method 600/R-93/116, EPA Method 600/M4-82-020
QA/QC Clerk
Reviewed By Authorized Signatory:
37-M22013-2
SRM 1866 Fiberglass
NAD = no asbestos detectedLEGEND:
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite. Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the
Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714 NVLAP #101882-0 VELAP 460172. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection.
Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy
(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.
400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.
* All California samples analyzed by Polarized Light Microscopy, EPA Method 600/M4-82-020, Dec. 1982.
2 of 2Page