Attachment 1_Schedule of Prices - 4 Option Years Final.pdf

PDF 679 KB Posted

Attached to
ROOF INSPECTION, REPAIR AND MAINTENANCE
Solicitation number
W912C326BA002
Issued by

About this file

This document is a detailed Schedule of Prices for roof repair, inspection, and maintenance services across four option periods. The comprehensive pricing schedule covers an extensive range of roofing services including roof inspection surveys, sampling and laboratory testing for asbestos, repairs for various roof types (concrete, corrugated metal, modified bitumen, lightweight concrete), removal and disposal of roofing materials, installation of new roofing components, blister repairs, maintenance, and related work such as framing, expansion joints, gutters, and electrical work.

The schedule provides unit pricing for each service item, measured in square feet (SF), linear feet (LF), each (EA), or ton (TON), with estimated quantities specified for each option period. Services encompass multiple roof types and systems including built-up roofing, EPDM membranes, asphalt shingles, metal roofing, and polyurethane coatings. The document details both removal/disposal and installation/repair processes for various roofing components, suggesting a comprehensive roof maintenance and renovation contract that allows for flexible, itemized service selection based on specific project needs.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Item Item Description Estimated Unit Quantity

0001 Roof Inspection Survey and Written Report with As-Built Roof Plan

50,000 SF

(Section 01 11 00, Para 1.2, 1.2.1, 1.2.2.a through h)

0002 Provide As-Built Roof Plans 50,000 SF (Section 01 11 00, Para 1.2.2)

0003 Sampling & Laboratory Testing and Test Report for Asbestos Materials

15 EA

(Section 01 11 00, Para 1.2.2.e and Para 1.4.6)

0004 Repair Concrete Roof (Plain Concrete) 1,500 SF (Section 01 11 00, Para 1.4.1.a, b, c, d, e) (See Tech Specs.)

0005 Repair Corrugated Metal Roof 5,000 SF (Section 01 11 00, Para 1.4.2.a, b, c) (See Tech Specs.)

Remove and Dispose Corrugated Metal Roof Panels, GA 24

520 SF

(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)

Install Corrugated Metal Roof Panels, GA 24 520 SF

(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)

Remove and Dispose Corrugated Metal Roof Panels, GA 26

520 SF

(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)

Install Corrugated Metal Roof Panels, GA 26

520 SF

(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)

Repair Corrugated Metal Roof: Painting 5,000 SF

0011 (Section 01 11 00, Para 1.4.2. d, f, and g)

Repair Modified Bitumen (Insulation, and 3-ply w/cold adhesvie) 200 SF

0012 (See Tech Specs.)

Repair Modified Bitumen (Insulation, and 3-ply w/torched seams) 200 SF

0013 (See Tech Specs.)

Repair Modified Bitumen (Insulation, and 2-ply w/cold 200 SF adhesive or torched seams) (See Tech Specs.)

Repair Light weight Concrete insulation, Lt weight

880 SF

cellular roof fill, Port & Cem. 2 inch thick average and foaming agent

(See Tech Specs.)

Remove and Dispose Light weight Concrete insulation, Lt weight 880 SF cellular roof fill, Port & Cem. 2 inch thick average and foaming agent

0017 (See Tech Specs.)

Install Light weight Concrete insulation, Lt weight 880 SF

0018 cellular roof fill, Port & Cem. 2 inch thick average and foaming agent

SCHEDULE OF PRICES

BASE OPTION PERIOD: ROOF REPAIR INSPECTION & MAINTENANCE

Unit Price Total Cost

(See Tech Specs.)

0019 Repair Light weight Concrete insulation, Lt weight

880 SF

cellular roof fill, Port & Cem. 4 inch thick average and foaming agent

(See Tech Specs.)

Remove and Dispose Light weight Concrete insulation, Lt weight 880 SF

0021 cellular roof fill, Port & Cem. 4 inch thick average and foaming agent

(See Tech Specs.)

0022 Install Light weight Concrete insulation, Lt weight

880 SF

cellular roof fill, Port & Cem. 4 inch thick average and foaming agent

(See Tech Specs.)

Remove and Dispose Insulation 2-inch Average Thick 1,500 SF

(See Tech Specs.)

Install Insulation 2-inch Average Thick (See Tech Specs.) 1,500 SF

Remove and Dispose E.P.D.M with Insulation

2,000 SF

(See Tech Specs.)

Install E.P.D.M with Insulation (See Tech Specs.) 2,000 SF

Remove and Dispose Built-up Roofing (Insulation 3-ply, Hot Adhesive and Gravel) (See Tech Specs.)

5,000 SF

Install Built-up Roofing (Insulation 3-ply, Hot Adhesive and Gravel) 5,000 SF

0028 (See Tech Specs.)

Repair Single Ply with adhesive or Asphalt Moppping 1,040 SF

0029 (See Tech Specs.)

Repair Insulation and Hot Asphalt Plies 520 SF

Remove and Dispose Standing Seam Metal Over Insulation

260 SF

0031 (Section 07 61 13)

Install Standing Seam Metal Over Insulation (Section 07 61 13)

260 SF

Remove and Dispose Asphalt Shingles over Insulation and over 100 SF standing Seam Metal Roof (See Tech Specs.)

Install Asphalt Shingles over Insulation and over

100 SF

standing Seam Metal Roof (See Tech Specs.)

Repair Water Proof Asphalt Coating 200 SF (See Tech Specs.)

Repair Sprayed Polyurethane with top Silicone Coating (PUF)

7,000 SF

0036 (See Tech Specs.)

Remove and Dispose Primer and Elastomeric Coating

7,000 SF

0037 (See Tech Specs.)

Install Primer and Elastomeric Coating 7,000 SF 0038 (See Tech Specs.)

Blisters Repairs for Modified Bitumen 300 SF

0039 (Section 01 11 00, Para 1.4.3) (See Tech Specs.)

Blister Repairs for E.P.D.M. 520 SF 0040 (Section 01 11 00, Para 1.4.3) (See Tech

Specs.)

0041 Blister Repairs for Built-up Roofing 1,040 SF (Section 01 11 00, Para 1.4.3) (See Tech Specs.)

0042 Blister Repairs for PUF 520 SF (Section 01 11 00, Para 1.4.5.d and e.(1) through (8) (See Tech Specs.)

0043 PUF Minor Repairs 260 SF (Section 01 11 00 , Para 1.4.5.C.(1) through

(5) (See Tech Specs.)

PUF or Built-up Roofing Repairs w/Asbestos Mastic (ACM) 260 SF

(Section 01 11 00, Para 1.4.6) (See Tech Specs.)

0045 PUF or Built-up Roofing Replacement w/Asbestos Mastic (ACM)

5,200 SF

(Section 01 11 00, Para 1.4.6) (See Tech Specs.)

Remove and Dispose Radiant Barrier Blanket

130,000 SF

Section 01 11 00, Para 1.5, 1.5.1 and 1.5.2) (See Tech Specs.)

Install Radiant Barrier Blanket 130,000 SF Section 01 11 00, Para 1.5, 1.5.1 and 1.5.2) (See Tech Specs.)

Repair Cracks at Roofing Systems 1,040 LF (Section 01 11 00, Para 1.4.3.e) (See Tech Specs.)

Correct Water Ponding Areas at Roofing Systems

1,040 SF

(Section 01 11 00, Para 1.4.3.d) (See Tech Specs.)

Maintenance for Roofing Systems 130,000 SF

0051 (Section 01 11 00, Par1.9.a through c) (See Tech Specs.)

Cement parging, 2 coats, waterproofed Portland cement (See Tech 1,040 SF

0052 Specs.)

Structural steel projects, steel surface treatments, wire brush, hand 520 SF

0053 sanding (See Tech Specs.)

Struct. steel projects,sprayed painting,univ primer plus1 paint coat,phenolic, 520 SF

0054 modified alkyd (See Tech Specs.)

Near white blast, (SSPC-10), exist coat blistered/pitted, 520 SF

0055 9.0 #/SF (See Tech Specs.)

0056 Structural steel project,pnts&prot ctg,sprayed,zinc rich primer,epoxy, 520 SF spray,organic (See Tech Specs.)

Strl st projs, pnts & prot ctg, sprayed, epoxy, intmd or topcoat (See Tech Specs.) 520 SF

Epoxy dk ctg, bitumen modified polyurethane, fld applied, 55 mils thk

520 SF

0058 (See Tech Specs.)

Remove and Dispose Open web joist girders, average (See Tech Specs.)

1 TON

Install Open web joist girders, average (See Tech Specs.)

1 TON

Remove and Dispose Lightweight framing, angle, field fab, 3" x 3" x 3/8" (See Tech Specs.) 45 LF

0061 Install Lightweight framing, angle, field fab, 3" x 3" x 3/8" (See Tech Specs.)

45 LF

Remove and Dispose Framing, joists, 2" x 12" (See Tech Specs.)

55 LF

Install Framing, joists, 2" x 12" (See Tech Specs.) 55 LF

Remove and Dispose Framing, joists, 2" x 4" (See Tech Specs.) 55 LF

Install Framing, joists, 2" x 4" (See Tech Specs.) 55 LF

Remove and Dispose Framing, joists, 2" x 6" (See Tech Specs.)

55 LF

Install Framing, joists, 2" x 6" (See Tech Specs.) 55 LF

0066 Remove and Dispose Framing, joists, 2" x 8" (See Tech Specs.) 55 LF

Install Framing, joists, 2" x 8" (See Tech Specs.) 55 LF

Remove and Dispose Framing, joists, 2" x 10" (See Tech Specs.)

55 LF

0068 Install Framing, joists, 2" x 10" (See Tech Specs.)

55 LF

Remove and Dispose Framing, roofs, fascia boards, 2" x 8" (See Tech Specs.)

55 LF

Install Framing, roofs, fascia boards, 2" x 8" (See Tech Specs.) 55 LF

Remove and Dispose Framing, roofs, rafters, to 4 in 12 pitch, 2" x 8" (See Tech Specs.) 55 LF

0071 Install Framing, roofs, rafters, to 4 in 12 pitch, 2" x 8" (See Tech Specs.) 55 LF

Remove and Dispose Framing, roofs, rafters, to 4 in 12 pitch, 2" x 6" (See Tech Specs.) 55 LF

Install Framing, roofs, rafters, to 4 in 12 pitch, 2" x 6" (See Tech Specs.) 55 LF

Remove and Dispose Framing, roofs, ridge board, #2 or better, 1" x 8" (See Tech Specs.) 55 LF

Install Framing, roofs, ridge board, #2 or better, 1" x 8" (See Tech Specs.) 55 LF

Remove and Dispose Framing, roofs, roof cants, split, 4" x 4" (See Tech Specs.) 55 LF

Install Framing, roofs, roof cants, split, 4" x 4" (See Tech Specs.) 55 LF

0076 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 55 LF

2" x 6" (See Tech Specs.)

Install Framing, miscellaneous, nailers, treated, wood construction, 55 LF

2" x 6" (See Tech Specs.)

Remove and Dispose Exp jt,butyl or nprn ctr W/foam insul,alum,.032"thk for opng to 104 LF

2-1/2" (See Tech Specs.)

Install Exp jt,butyl or nprn ctr W/foam insul,alum,.032"thk for opng to 104 LF

2-1/2" (See Tech Specs.)

Remove and Dispose Exp jt, butyl or nprn ctr W/foam insul, alum, for jt opngs to 104 LF

3-1/2" (See Tech Specs.)

Install Exp jt, butyl or nprn ctr W/foam insul, alum, for jt opngs to 104 LF

3-1/2" (See Tech Specs.)

Remove and Dispose Expansion joint, roof joint with extruded aluminum cover, 2" (See Tech Specs.)

55 LF

Install Expansion joint, roof joint with extruded aluminum cover, 2" (See Tech Specs.) 55 LF

Remove and Dispose Expansion joint, roof to wall joint with extruded aluminum cover (See Tech Specs.)

55 LF

Install Expansion joint, roof to wall joint with extruded aluminum cover 55 LF

(See Tech Specs.)

Remove and Dispose Expansion joint, wall joint, closed cell foam on PVC

55 LF

0086 cover, 9" wide (See Tech Specs.)

Remove and Dispose Expansion joint, wall joint, closed cell foam on PVC 55 LF

0087 cover, 9" wide (See Tech Specs.)

Remove and Dispose Expansion jt, neoprene, dbl-seal type with thick center, 4-1/2" wide (See Tech Specs.)

55 LF

Install Expansion jt, neoprene, dbl-seal type with thick center, 55 LF

4-1/2" wide (See Tech Specs.)

Cleaning high pressure water only, minimum (See Tech Specs.)

130,000 SF

Remove and Dispose Sheathing, with boards, 1" x 12" boards, laid diagonal (See Tech Specs.) 55 SF

0091 Install Sheathing, with boards, 1" x 12" boards, laid diagonal (See Tech Specs.)

55 SF

Remove and Dispose Sheathing, plywood on roof, CDX, 5/8" thick (See Tech Specs.) 55 SF

Install Sheathing, plywood on roof, CDX, 5/8" thick (See Tech Specs.)

55 SF

Remove and Dispose Steel roofing, on steel frame, corrugated or ribbed, galv, 24 ga (See Tech Specs.)

55 SF

Install Steel roofing, on steel frame, corrugated or ribbed, galv, 24 ga

55 SF

0094 (See Tech Specs.)

Remove and Dispose Steel roofing, on steel frame, corrugated or ribbed, galv, 26 ga (See Tech

55 SF

Install Steel roofing, on steel frame, corrugated or ribbed, galv, 26 ga

55 SF

0096 (See Tech Specs.)

Remove and Dispose roof flat profile, 1-3/4" stand. seams, 12" w, stand. fin. 24 ga. (See Tech Specs.)

55 SF

Install Steel roof flat profile, 1-3/4" stand.

seams, 12" w, stand. fin. 24 ga.

55 SF

(See Tech Specs.)

Remove and Dispose Aluminum roofing, corrugated, painted, .032" thick (See Tech Specs.) 55 SF

Install Aluminum roofing, corrugated, painted, .032" thick (See Tech 55 SF

Specs.)

Remove and Dispose Asphalt shingles, #15 felt underlayment (See Tech Specs.) 55 SF

0101 Install Asphalt shingles, #15 felt underlayment (See Tech Specs.)

55 SF

Remove and Dispose Asphalt shingles, std strip shingles, inorganic, class A, 210-235 lb/sq (See Tech Specs.)

55 SF

Install Asphalt shingles, std strip shingles, inorganic, class A, 55 SF

210-235 lb/sq (See Tech Specs.)

Remove and Dispose Steel roofing, ridge, galvanized, 20" wide (See Tech Specs.) 55 LF

0104 Install Steel roofing, ridge, galvanized, 20" wide (See Tech Specs.)

55 LF

Remove and Dispose Fascia, aluminum, .032" thick, colored, NO furring included (See Tech Specs.) 55 SF

Install Fascia, aluminum, .032" thick, colored, NO furring included

55 SF

0106 (See Tech Specs.)

Remove and Dispose Fascia, steel, galv and enameled, stock, NO furring, 55 SF

0107 long panels (See Tech Specs.)

Install Fascia, steel, galv and enameled, stock, NO furring, 55 SF

0108 long panels (See Tech Specs.)

Remove and Dispose Gutters, aluminum, 5" box type, enameled (See Tech Specs.)

160 LF

Install Gutters, aluminum, 5" box type, enameled (See Tech Specs.) 160 LF

Remove and Dispose Gutters, alum, 5" x 6" comb fascia & gutter, .032" thick, 160 LF enameled (See Tech Specs.)

Install Gutters, alum, 5" x 6" comb fascia & gutter, .032" thick, 160 LF enameled (See Tech Specs.)

Remove and Dispose Gutters, steel, galv, half round or box, 28 ga, 5" 104 LF wide, enameled (See Tech Specs.)

Install Gutters, steel, galv, half round or box, 28 ga, 5" wide, 104 LF enameled (See Tech Specs.)

Remove and Dispose Gravel stop, galv steel, 6" face height (See Tech Specs.) 104 LF

Install Gravel stop, galv steel, 6" face height (See Tech Specs.) 104 LF

0116 Remove and Dispose Gravel stop, aluminum, .050" thick, 6" height, painted (See Tech Specs.) 104 LF

Install Gravel stop, aluminum, .050" thick, 6" height, painted (See Tech Specs.) 104 LF

Remove and Dispose Gravel Gravel stop, aluminum, .050" thick, 8" height, painted (See Tech Specs.)

104 LF

Install Gravel stop, aluminum, .050" thick, 8" height, painted (See Tech Specs.) 104 LF

Remove and Dispose Gravel Gravel Gutters, aluminum, 5" box type, .032" thick, plain (See Tech Specs.)

160 LF

Install Gutters, aluminum, 5" box type, .032" thick, plain (See Tech Specs.) 160 LF

0120 LF

0121 Install Gutters, steel, galv, half round or box, 28 ga, 5" wide, plain (See Tech Specs.) 160 LF

Remove and Dispose Gravel stop, aluminum, .050" thick, 6" height, duranodic finish 104 LF

0122 (See Tech Specs.)

Install Gravel stop, aluminum, .050" thick, 6" height, duranodic finish

104 LF

0123 (See Tech Specs.)

Remove and Dispose Gravel stop, aluminum, .050" thick, 8" height, duranodic finish (See Tech Specs.)

104 LF

Install Gravel stop, aluminum, .050" thick, 8" height, duranodic finish

104 LF

(See Tech Specs.)

Remove and Dispose Downspouts, aluminum 3" x 4", .024" thick, enameled (See Tech Specs.) 60 LF

Install Downspouts, aluminum 3" x 4", .024" thick, enameled (See Tech Specs.) 60 LF

Remove and Dispose Downspouts, steel, rectangular, plain, 28 ga, galvanized, 3" x 4" (See Tech Specs.)

60 LF

Install Downspouts, steel, rectangular, plain, 28 ga, galvanized, 60 LF

0128 3" x 4" (See Tech Specs.)

Remove and Dispose Downspouts, steel, rect, epoxy painted, 24 ga, corrugated, 60 LF

0129 3" x 4" (See Tech Specs.)

Install Downspouts, steel, rect, epoxy painted, 24 ga, corrugated, 60 LF

0130 3" x 4" (See Tech Specs.)

0131 Remove and Dispose Drip edge, aluminum, .016" thick, 5" wide, mill finish (See Tech Specs.) 60 LF

Install Drip edge, aluminum, .016" thick, 5" wide, mill finish (See Tech Specs.)

60 LF

Remove and Dispose Gutters, steel, galv, half round or box, 28 ga, 5" wide, plain (See Tech Specs.)

Remove and Dispose and Dispose Drip edge, aluminum, .016" thick, 5" wide, white finish (See Tech Specs.)

60 LF

0133 Install Drip edge, aluminum, .016" thick, 5" wide, white finish (See Tech Specs.)

60 LF

Remove and Dispose Drip edge, galvanized, 5" wide, mill finish (See Tech Specs.) 60 LF

Install Drip edge, galvanized, 5" wide, mill finish (See Tech Specs.)

60 LF

Remove and Dispose Elbows, aluminum, 3" x 4", .025" thick, embossed (See Tech Specs.) 26 EA

0136 Install Elbows, aluminum, 3" x 4", .025" thick, embossed (See Tech Specs.)

26 EA

Remove and Dispose Elbows, aluminum, 3" x 4", .025" thick, enameled (See Tech Specs.) 26 EA

Install Elbows, aluminum, 3" x 4", .025" thick, enameled (See Tech Specs.)

26 EA

0138 Remove and Dispose Flashing, aluminum, mill finish, .032" thick (See Tech Specs.)

90 SF

Install Flashing, aluminum, mill finish, .032" thick (See Tech Specs.)

90 SF

Remove and Dispose Vent flashing, aluminum with lead ring, 2" pipe (See Tech Specs.) 9 EA

0140 Install Vent flashing, aluminum with lead ring, 2" pipe (See Tech Specs.)

9 EA

Remove and Dispose Vent flashing, aluminum with lead ring, 3" pipe (See Tech Specs.) 9 EA

Install Vent flashing, aluminum with lead ring, 3" pipe (See Tech Specs.) 9 EA

Remove and Dispose Vent flashing, aluminum with lead ring, 4" pipe (See Tech Specs.) 9 EA

0143 Install Vent flashing, aluminum with lead ring, 4" pipe (See Tech Specs.)

9 EA

Remove and Dispose Vent flashing, aluminum with lead ring, 1-1/2" pipe (See Tech Specs.) 9 EA

Install Vent flashing, aluminum with lead ring, 1-1/2" pipe (See Tech

9 EA

Specs.)

Remove and Dispose Reglet, counter flashing for above, 12" wide, .032" aluminum (See Tech Specs.) 44 LF

Install Reglet, counter flashing for above, 12" wide, .032" aluminum 44 LF

(See Tech Specs.)

Remove and Dispose Roof vents, mushroom for built-up roofs, PVC, 6"

16 EA

high

Install Roof vents, mushroom for built-up roofs, PVC, 6" high

16 EA

Remove and Dispose Vents, one-way, aluminum (See Tech Specs.) 16 EA

Install Vents, one-way, aluminum (See Tech Specs.) 16 EA

Remove and Dispose Drains-scppr flr, oblique strn-CI, 6"x7" top, 2", 3"&4" pipe size (See Tech Specs.)

4 EA

Install Drains-scppr flr, oblique strn-CI, 6"x7" top, 2", 3"&4" pipe size 4 EA

(See Tech Specs.)

Remove and Dispose Drains, roof, flat metal deck, C.I. body, 12" C.I. 4 EA dome, 3" pipe size (See Tech Specs.)

Install Drains, roof, flat metal deck, C.I. body, 12" C.I. dome, 4 EA

3" pipe size (See Tech Specs.)

Remove and Dispose Drains, roof, flat mtl deck, galvanized body, 12"CI dome, 6" pipe (See Tech Specs.)

4 EA

0155 Install Drains, roof, flat mtl deck, galvanized body, 12"CI dome, 6" pipe

4 EA

(See Tech Specs.)

Remove and Dispose Drains, cornice, C.I., 45< or 90< outlet, 3" and 4" pipe size (See Tech Specs.) 4 EA

0157 Install Drains, cornice, C.I., 45< or 90< outlet, 3" and 4" pipe size

4 EA

(See Tech Specs.)

Remove and Dispose Drains, cornice, C.I., for galvanized body, 3" and 4" pipe size (See Tech Specs.) 4 EA

Install Drains, cornice, C.I., for galvanized body, 3" and 4" pipe size

4 EA

0159 (See Tech Specs.)

Remove and Dispose Elastomeric rfg,poly spray-on W/20mil silicone rbr ctg , 3"thk,r21,min (See Tech Specs.)

1,600 SF

Install Elastomeric rfg,poly spray-on W/20mil silicone rbr ctg , 1,600 SF

0161 3"thk,r21,min (See Tech Specs.)

Remove and Dispose Built-up rfg,asph fl CT W/gvl,ctd gl base sht,3ply gl,nailable dk (See Tech Specs.)

5,200 SF

Install Built-up rfg,asph fl CT W/gvl,ctd gl base sht,3ply gl,nailable dk 5,200 SF

(See Tech Specs.)

Remove and Dispose Built-up rfg,asph fl CT W/gvl,ctd gl base sht,4ply gl 5,200 SF fbr felt,mopped

Install Built-up rfg,asph fl CT W/gvl,ctd gl base sht,4ply gl 5,200 SF fbr felt,mopped

Remove and Dispose Cants, 4" x 4" treated timber, cut diagonally (See Tech Specs.) 90 LF

Install Cants, 4" x 4" treated timber, cut diagonally (See Tech Specs.) 90 LF

Remove and Dispose B247Single-ply membrane, EPDM, 60 mil, 0.40 PS, fully 5,200 SF adhered w/adhesive, w/4" seam tape (See Tech Specs.)

0168 Install B247Single-ply membrane, EPDM, 60 mil, 0.40 PS, fully

5,200 SF

adhered w/adhesive, w/4" seam tape (See Tech Specs.)

Remove and Dispose Mod bit rfng, SBS mod, gran surf cap sheet, poly rein, mppd, 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to

1,040 SF

deck w/asphalt primer (See Tech Specs.)

Install Mod bit rfng, SBS mod, gran surf cap sheet, poly rein, mppd, 1,040 SF

160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to

0171 deck w/asphalt primer (See Tech Specs.)

Remove and Dispose Mod bit, SBS mod, smooth surf cap sheet, glass fiber rein, mppd, 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped

1,040 SF

0172 to deck w/asphalt primer (See Tech Specs.)

Install Mod bit, SBS mod, smooth surf cap sheet, glass fiber rein, mppd, 1,040 SF

160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to deck w/asphalt primer (See Tech Specs.)

Remove and Dispose Mod bit, APP mod, gran surface cap sheet, poly 1,040 SF rein, torched, 180 mils w/base sheet, #15 Glass Fiber Felt fully mopped to deck w/asphalt primer (See Tech Specs.)

Install Mod bit, APP mod, gran surface cap sheet, poly rein, 1,040 SF

0176 torched, 180 mils w/base sheet, #15 Glass Fiber Felt fully mopped to deck w/asphalt primer (See Tech Specs.)

Remove and Dispose Mod bit, APP mod, smooth surf cap sheet, poly rein, torched, 1,040 SF

160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to deck w/asphalt primer (See Tech Specs.)

Install Mod bit, APP mod, smooth surf cap sheet, poly rein, torched, 1,040 SF

160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to

0179 deck w/asphalt primer (See Tech Specs.)

Remove and Dispose Roof coatings, asphalt primer, 5 gallon (See Tech Specs.)

20,000 SF

Install Roof coatings, asphalt primer, 5 gallon (See Tech Specs.)

20,000 SF

Remove and Dispose Bituminous asphalt coating, with fibers, troweled on, 1/2" thick (See Tech Specs.)

2,600 SF

Install Bituminous asphalt coating, with fibers, troweled on, 1/2" thick 2,600 SF

(See Tech Specs.)

Remove and DisposeBuilt-up rfg,asph fl CT,ctd gl fbr base sht,3 plies,on nailable dks (See Tech Specs.) 2,000 SF

Install Built-up rfg,asph fl CT,ctd gl fbr base sht,3 plies,on nailable dks

2,000 SF

0184 (See Tech Specs.)

Remove and Dispose Built-up rfg,asph fl CT,ctd gl fbr base sht,4ply gl fbr felt,mopped (See Tech Specs.)

2,000 SF

Install Built-up rfg,asph fl CT,ctd gl fbr base sht,4ply gl fbr felt,mopped

2,000 SF

0186 (See Tech Specs.)

Remove and Dispose Rubber coating, silicone or stearate, sprayed on CMU, 2 coats (See Tech Specs.) 1,040 SF

Install Rubber coating, silicone or stearate, sprayed on CMU, 2 coats 1,040 SF

(See Tech Specs.)

Remove and Dispose Pitch Pockets, side extenders, 6" (See Tech 18 EA

Specs.)

Install Pitch Pockets, side extenders, 6" (See Tech Specs.) 18 EA

Remove and Dispose Pitch Pockets, adjustable, 4" to 7", welded corners, 4" deep (See Tech Specs.) 18 EA

0191 Install Pitch Pockets, adjustable, 4" to 7", welded corners, 4" deep 18 EA

(See Tech Specs.)

Remove and Dispose Walkway for BUR, asph impregnated, 3' x 3' x 3/4" thk (See Tech Specs.) 700 SF

Install Walkway for BUR, asph impregnated, 3' x 3' x 3/4" thk (See Tech Specs.) 700 SF

Remove and Dispose Caulking & sealants, polyurethane, 1 or 2 component, bulk (See Tech Specs.)

90 LF

0194 Install Caulking & sealants, polyurethane, 1 or 2 component, bulk

90 LF

(See Tech Specs.)

Remove and Dispose Caulking and sealants, silicone rubber, cartridges (See Tech Specs.) 90 LF

0196 Install Caulking and sealants, silicone rubber, cartridges (See Tech 90 LF

Specs.)

Remove and Dispose Caulking and sealants, resin epoxy coating, 2 component, heavy duty (See Tech Specs.)

90 LF

Install Caulking and sealants, resin epoxy coating, 2 component, heavy

90 LF

0198 duty (See Tech Specs.)

Remove and Dispose Caulking and sealants, neoprene gaskets, closed cell, 1/4" x 3/4" (See Tech Specs.)

90 LF

Install Caulking and sealants, neoprene gaskets, closed cell, 1/4" x 3/4"

90 LF

(See Tech Specs.)

Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 6" (See Tech Specs.)

90 LF

Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 6"

90 LF

Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 4" (See Tech Specs.)

90 LF

Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 4" 90 LF

(See Tech Specs.)

Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 8" (See Tech Specs.)

90 LF

Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 8"

90 LF

0205 (See Tech Specs.)

Remove and Dispose Roof deck insul, polyisocyanurate, 2#/CF density, 2" thk R14.29 (See Tech Specs.)

5,000 SF

Install Roof deck insul, polyisocyanurate, 2#/CF density, 2" thk R14.29

5,000 SF

0207 (See Tech Specs.)

Remove and Dispose Roof deck insulation, polyisocyanurate 2#/CF

5,000 SF

density, tapered for drainage (See Tech Specs.)

Install Roof deck insulation, polyisocyanurate 2#/CF density, 5,000 SF

0209 tapered for drainage (See Tech Specs.)

Remove and Dispose Roof deck insulation, expanded polystyrene, 2" thick R7.69 (See Tech Specs.) 5,000 SF

Install Roof deck insulation, expanded polystyrene, 2" thick R7.69

5,000 SF

0211 (See Tech Specs.)

Remove and Dispose Roof deck insulation, expanded polystyrene, tapered for drainage (See Tech Specs.)

880 SF

Install Roof deck insulation, expanded polystyrene, tapered for drainage

880 SF

(See Tech Specs.)

Remove and Dispose Roof deck insul., extruded polystyrene, 60 PSI

4,000 SF

comp. strength, 2" thick R10 (See Tech Specs.)

Install Roof deck insul., extruded polystyrene, 60 PSI comp. 4,000 SF strength, 2" thick R10 (See Tech Specs.)

Remove and Dispose Roof deck insul., extruded polystyrene, 60 PSI comp. strgth., tapered (See Tech Specs.)

1,040 SF

Install Roof deck insul., extruded polystyrene, 60 PSI comp. strgth., tapered 1,040 SF

(See Tech Specs.)

Remove and Dispose Roof hatch, 2'-6" x 3', w/curb, 1" fbgls insul, galv stl curb/cover (See Tech Specs.)

1 EA

0218 Install Roof hatch, 2'-6" x 3', w/curb, 1" fbgls insul, galv stl curb/cover

1 EA

(See Tech Specs.)

Remove and Dispose Skylight, insulated safety glass with aluminum frame (See Tech Specs.) 260 SF

Install Skylight, insulated safety glass with aluminum frame (See Tech Specs.)

160 SF

Remove and Dispose Ladder, steel, 20" wide, bolted to concrete, with cage (See Tech Specs.) 70 VLF

Install Ladder, steel, 20" wide, bolted to concrete, with cage (See Tech Specs.)

70 VLF

Remove and DisposeLadder, steel, 20" wide, bolted to concrete, w/o cage (See Tech Specs.) 70 VLF

Install Ladder, steel, 20" wide, bolted to concrete, w/o cage (See Tech Specs.)

70 VLF

Replace Insulation/finish syst, field applied, 1 inch (See Tech Specs.)

520 SF

Replace Insulation/finish syst, field applied, 2 inch (See Tech Specs.) 260 SF

Replace Insulation/finish syst, field applied, 3 inch (See Tech Specs.) 260 SF

Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 18"w (See Tech Specs.)

90 LB

Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 24"w (See Tech Specs.) 90 LB

0227 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 48"w (See Tech Specs.)

90 LB

Pipe, copper, 3/8" dia., type K (See Tech Specs.)

160 LF

Pipe insulation, 3/8" copper pipe, rubber tubing (See Tech Specs.)

160 LF

Vent and Pipe Replacement, PVC schedule 40, 2" dia. (See Tech Specs.) 18 LF

Vent and Pipe Replacement, PVC schedule 40, 3" dia. (See Tech Specs.) 18 LF

Vent and Pipe Replacement, PVC schedule 40, 4" dia. (See Tech Specs.)

18 LF

HVAC demo, Mech equipment (See Tech Specs.)

2,000 LBS

0232 Air cooled condenser, 2 tons, reinstallation (See Tech Specs.)

6 EA

Air cooled condenser, 16 tons,reinstallation (See Tech Specs.) 6 EA

Roof top unit, 7.5 tons, single zone, reinstallation (See Tech Specs.) 6 EA

Replace Wire, 600 volt, type THW, copper, stranded, #12 (See Tech Specs.) 200 LF

Replace Wire, 600 volt, type THW, copper, solid, #12 (See Tech Specs.)

200 LF

Replace Wire, 600 volt, type THW, copper, stranded, #10 (See Tech Specs.)

200 LF

Replace Wire, 600 volt, type THW, copper, solid, #10 (See Tech Specs.) 200 LF

Replace Wire, 600 volt, type THW, copper, stranded, #8 (See Tech 200 LF

Specs.)

Replace Wire, 600 volt, type THW, copper, stranded, #6 (See Tech 200 LF

ReplaceWire, 600 volt, type THW, copper, stranded, #4 (See Tech 200 LF

Specs.)

Replace Wire, 600 volt, type THW, copper, stranded, #3 (See Tech 200 LF

Specs.)

Replace Wire, 600 volt, type THW, copper, stranded, #2 (See Tech 200 LF

Specs.)

Replace Wire, 600 volt, type THW, copper, stranded, #1 (See Tech 200 LF

Specs.)

Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #12 (See Tech Specs.) 200 LF

Replace Wire, 600 volt, type THWN-THHN, copper, solid, #12 (See Tech Specs.) 200 LF

Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #10 (See Tech Specs.) 200 LF

Replace Wire, 600 volt, type THWN-THHN, copper, solid, #10 (See Tech Specs.)

200 LF

Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #8 (See Tech Specs.)

200 LF

Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #6 (See Tech Specs.) 200 LF

Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #4 (See Tech Specs.) 200

Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1/2" dia 100

(See Tech Specs.)

Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3/4" dia 100

(See Tech Specs.)

Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1"

0251 dia (See Tech Specs.)

Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1-1/4"dia (See Tech Specs.) 100

Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1-1/2"dia (See Tech Specs.) 100

0253 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,2" dia (See Tech Specs.)

Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,2-1/2"dia (See Tech Specs.) 100

Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3" 100

0255 dia (See Tech Specs.)

0256 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3-1/2"dia (See Tech Specs.) 100

Relace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,4" 100

0257 dia (See Tech Specs.)

Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 30 amp (See Tech Specs.) 8

Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 60 amp (See Tech Specs.) 8

Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 100 amp (See Tech Specs.) 8

Replace Wire, 600 volt, type THW, copper, stranded, 1/0 (See Tech Specs.)

Replace Wire, 600 volt, type THW, copper, stranded, 2/0 (See Tech Specs.)

Replace Wire, 600 volt, type THW, copper, stranded, 3/0 (See Tech Specs.) 100

Replace Wire, 600 volt, type THW, copper, stranded, 4/0 (See Tech Specs.) 100

Uninstall and Disconnect Solar Panels /Reinstallation- Mounting, panels, Reactivation 400

0001 Grand Total

Estimated Quantity

1001 Roof Inspection Survey and Written Report with As-Built Roof Plan

50,000 SF

(Section 01 11 00, Para 1.2, 1.2.1, 1.2.2.a through h)

1002 Provide As-Built Roof Plans 50,000 SF (Section 01 11 00, Para 1.2.2)

1003 Sampling & Laboratory Testing and Test Report for Asbestos Materials

15 EA

(Section 01 11 00, Para 1.2.2.e and Para 1.4.6)

1004 Repair Concrete Roof (Plain Concrete) 1,500 SF (Section 01 11 00, Para 1.4.1.a, b, c, d, e) (See Tech Specs.)

1005 Repair Corrugated Metal Roof 5,000 SF (Section 01 11 00, Para 1.4.2.a, b, c) (See Tech Specs.)

Remove and Dispose Corrugated Metal Roof Panels, GA 24

520 SF

(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)

Install Corrugated Metal Roof Panels, GA 24 520 SF

(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)

Remove and Dispose Corrugated Metal Roof Panels, GA 26

520 SF

Remove & dispose PUF or Built-up Roofing w/Asbestos Mastic (ACM)

SCHEDULE OF PRICES

1st OPTION PERIOD: ROOF REPAIR INSPECTION & MAINTENANCE

Item Item Description Unit Unit Price Total Cost

(Section 01 11 00, Para 1.4.2.e) (See Tech

Install Corrugated Metal Roof Panels, GA 26

520 SF

(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)

Repair Corrugated Metal Roof: Painting 5,000 SF

1011 (Section 01 11 00, Para 1.4.2. d, f, and g)

Repair Modified Bitumen (Insulation, and 3-ply w/cold adhesvie) 200 SF

1012 (See Tech Specs.)

Repair Modified Bitumen (Insulation, and 3-ply w/torched seams) 200 SF

1013 (See Tech Specs.)

Repair Modified Bitumen (Insulation, and 2-ply w/cold 200 SF adhesive or torched seams) (See Tech Specs.)

Repair Light weight Concrete insulation, Lt weight

880 SF

cellular roof fill, Port & Cem. 2 inch thick average and foaming agent

(See Tech Specs.)

Remove and Dispose Light weight Concrete insulation, Lt weight 880 SF cellular roof fill, Port & Cem. 2 inch thick average and foaming agent

1017 (See Tech Specs.)

Install Light weight Concrete insulation, Lt weight 880 SF

1018 cellular roof fill, Port & Cem. 2 inch thick average and foaming agent

(See Tech Specs.)

1019 Repair Light weight Concrete insulation, Lt weight

880 SF

cellular roof fill, Port & Cem. 4 inch thick average and foaming agent

(See Tech Specs.)

Remove and Dispose Light weight Concrete insulation, Lt weight 880 SF

1021 cellular roof fill, Port & Cem. 4 inch thick average and foaming agent

(See Tech Specs.)

1022 Install Light weight Concrete insulation, Lt weight

880 SF

cellular roof fill, Port & Cem. 4 inch thick average and foaming agent

(See Tech Specs.)

Remove and Dispose Insulation 2-inch Average Thick 1,500 SF

(See Tech Specs.)

Install Insulation 2-inch Average Thick (See Tech Specs.) 1,500 SF

Remove and Dispose E.P.D.M with Insulation

2,000 SF

(See Tech Specs.)

Install E.P.D.M with Insulation (See Tech Specs.) 2,000 SF

Remove and Dispose Built-up Roofing (Insulation 3-ply, Hot Adhesive and Gravel) (See Tech

5,000 SF

Install Built-up Roofing (Insulation 3-ply, Hot Adhesive and Gravel) 5,000 SF

1028 (See Tech Specs.)

Repair Single Ply with adhesive or Asphalt Moppping 1,040 SF

1029 (See Tech Specs.)

Repair Insulation and Hot Asphalt Plies 520 SF

Remove and Dispose Standing Seam Metal Over Insulation

260 SF

1031 (Section 07 61 13)

Install Standing Seam Metal Over Insulation (Section 07 61 13)

260 SF

Remove and Dispose Asphalt Shingles over Insulation and over 100 SF standing Seam Metal Roof (See Tech Specs.)

Install Asphalt Shingles over Insulation and over

100 SF

standing Seam Metal Roof (See Tech Specs.)

Repair Water Proof Asphalt Coating 200 SF (See Tech Specs.)

Repair Sprayed Polyurethane with top Silicone Coating (PUF)

7,000 SF

1036 (See Tech Specs.)

Remove and Dispose Primer and Elastomeric Coating

7,000 SF

1037 (See Tech Specs.)

Install Primer and Elastomeric Coating 7,000 SF 1038 (See Tech Specs.)

Blisters Repairs for Modified Bitumen 300 SF 1039 (Section 01 11 00, Para 1.4.3) (See Tech

Specs.)

Blister Repairs for E.P.D.M. 520 SF 1040 (Section 01 11 00, Para 1.4.3) (See Tech

Specs.)

1041 Blister Repairs for Built-up Roofing 1,040 SF (Section 01 11 00, Para 1.4.3) (See Tech Specs.)

1042 Blister Repairs for PUF 520 SF (Section 01 11 00, Para 1.4.5.d and e.(1) through (8) (See Tech Specs.)

1043 PUF Minor Repairs 260 SF (Section 01 11 00 , Para 1.4.5.C.(1) through

(5) (See Tech Specs.)

PUF or Built-up Roofing Repairs w/Asbestos Mastic (ACM) 260 SF

(Section 01 11 00, Para 1.4.6) (See Tech Specs.)

1045 PUF or Built-up Roofing Replacement w/Asbestos Mastic (ACM)

5,200 SF

(Section 01 11 00, Para 1.4.6) (See Tech Specs.)

Remove and Dispose Radiant Barrier Blanket

130,000 SF

Section 01 11 00, Para 1.5, 1.5.1 and 1.5.2) (See Tech Specs.)

Install Radiant Barrier Blanket 130,000 SF Section 01 11 00, Para 1.5, 1.5.1 and 1.5.2)

Repair Cracks at Roofing Systems 1,040 LF (Section 01 11 00, Para 1.4.3.e) (See Tech Specs.)

Correct Water Ponding Areas at Roofing Systems

1,040 SF

(Section 01 11 00, Para 1.4.3.d) (See Tech Specs.)

Maintenance for Roofing Systems 130,000 SF

1051 (Section 01 11 00, Par1.9.a through c) (See Tech Specs.)

Cement parging, 2 coats, waterproofed Portland cement (See Tech 1,040 SF

1052 Specs.)

Structural steel projects, steel surface treatments, wire brush, hand 520 SF

1053 sanding (See Tech Specs.)

Struct. steel projects,sprayed painting,univ primer plus1 paint coat,phenolic, 520 SF

1054 modified alkyd (See Tech Specs.)

Near white blast, (SSPC-10), exist coat blistered/pitted, 520 SF

1055 9.0 #/SF (See Tech Specs.)

1056 Structural steel project,pnts&prot ctg,sprayed,zinc rich primer,epoxy, 520 SF spray,organic (See Tech Specs.)

Strl st projs, pnts & prot ctg, sprayed, epoxy, intmd or topcoat (See Tech Specs.) 520 SF

Epoxy dk ctg, bitumen modified polyurethane, fld applied, 55 mils thk

520 SF

1058 (See Tech Specs.)

Remove and Dispose Open web joist girders, average (See Tech Specs.)

1 TON

Install Open web joist girders, average (See Tech Specs.)

1 TON

Remove and Dispose Lightweight framing, angle, field fab, 3" x 3" x 3/8" (See Tech Specs.) 45 LF

1061 Install Lightweight framing, angle, field fab, 3" x 3" x 3/8" (See Tech Specs.)

45 LF

Remove and Dispose Framing, joists, 2" x 12" (See Tech Specs.)

55 LF

Install Framing, joists, 2" x 12" (See Tech Specs.) 55 LF

Remove and Dispose Framing, joists, 2" x 4" (See Tech Specs.) 55 LF

Install Framing, joists, 2" x 4" (See Tech Specs.) 55 LF

Remove and Dispose Framing, joists, 2" x 6" (See Tech Specs.)

55 LF

Install Framing, joists, 2" x 6" (See Tech Specs.) 55 LF

1066 Remove and Dispose Framing, joists, 2" x 8" (See Tech Specs.) 55 LF

Install Framing, joists, 2" x 8" (See Tech Specs.) 55 LF

Remove and Dispose Framing, joists, 2" x 10"

55 LF

1068 Install Framing, joists, 2" x 10" (See Tech Specs.)

55 LF

Remove and Dispose Framing, roofs, fascia boards, 2" x 8" (See Tech Specs.)

55 LF

Install Framing, roofs, fascia boards, 2" x 8" (See Tech Specs.) 55 LF

Remove and Dispose Framing, roofs, rafters, to 4 in 12 pitch, 2" x 8" (See Tech Specs.) 55 LF

1071 Install Framing, roofs, rafters, to 4 in 12 pitch, 2" x 8" (See Tech Specs.) 55 LF

Remove and Dispose Framing, roofs, rafters, to 4 in 12 pitch, 2" x 6" (See Tech Specs.) 55 LF

Install Framing, roofs, rafters, to 4 in 12 pitch, 2" x 6" (See Tech Specs.) 55 LF

Remove and Dispose Framing, roofs, ridge board, #2 or better, 1" x 8" (See Tech Specs.) 55 LF

Install Framing, roofs, ridge board, #2 or better, 1" x 8" (See Tech Specs.) 55 LF

Remove and Dispose Framing, roofs, roof cants, split, 4" x 4" (See Tech Specs.) 55 LF

Install Framing, roofs, roof cants, split, 4" x 4" (See Tech Specs.) 55 LF

1076 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 55 LF

2" x 6" (See Tech Specs.)

Install Framing, miscellaneous, nailers, treated, wood construction, 55 LF

2" x 6" (See Tech Specs.)

Remove and Dispose Exp jt,butyl or nprn ctr W/foam insul,alum,.032"thk for opng to 104 LF

2-1/2" (See Tech Specs.)

Install Exp jt,butyl or nprn ctr W/foam insul,alum,.032"thk for opng to 104 LF

2-1/2" (See Tech Specs.)

Remove and Dispose Exp jt, butyl or nprn ctr W/foam insul, alum, for jt opngs to 104 LF

3-1/2" (See Tech Specs.)

Install Exp jt, butyl or nprn ctr W/foam insul, alum, for jt opngs to 104 LF

3-1/2" (See Tech Specs.)

Remove and Dispose Expansion joint, roof joint with extruded aluminum cover, 2" (See Tech Specs.)

55 LF

Install Expansion joint, roof joint with extruded aluminum cover, 2" (See Tech Specs.) 55 LF

Remove and Dispose Expansion joint, roof to wall joint with extruded aluminum cover (See Tech Specs.)

55 LF

Install Expansion joint, roof to wall joint with extruded aluminum cover 55 LF

Remove and Dispose Expansion joint, wall joint, closed cell foam on PVC

55 LF

1086 cover, 9" wide (See Tech Specs.)

Remove and Dispose Expansion joint, wall joint, closed cell foam on PVC 55 LF

1087 cover, 9" wide (See Tech Specs.)

Remove and Dispose Expansion jt, neoprene, dbl-seal type with thick center, 4-1/2" wide (See Tech Specs.)

55 LF

Install Expansion jt, neoprene, dbl-seal type with thick center, 55 LF

4-1/2" wide (See Tech Specs.)

Cleaning high pressure water only, minimum (See Tech Specs.)

130,000 SF

Remove and Dispose Sheathing, with boards, 1" x 12" boards, laid diagonal (See Tech Specs.) 55 SF

1091 Install Sheathing, with boards, 1" x 12" boards, laid diagonal (See Tech Specs.)

55 SF

Remove and Dispose Sheathing, plywood on roof, CDX, 5/8" thick (See Tech Specs.) 55 SF

Install Sheathing, plywood on roof, CDX, 5/8" thick (See Tech Specs.)

55 SF

Remove and Dispose Steel roofing, on steel frame, corrugated or ribbed, galv, 24 ga (See Tech Specs.)

55 SF

Install Steel roofing, on steel frame, corrugated or ribbed, galv, 24 ga

55 SF

1094 (See Tech Specs.)

Remove and Dispose Steel roofing, on steel frame, corrugated or ribbed, galv, 26 ga (See Tech Specs.)

55 SF

Install Steel roofing, on steel frame, corrugated or ribbed, galv, 26 ga

55 SF

1096 (See Tech Specs.)

Remove and Dispose roof flat profile, 1-3/4" stand. seams, 12" w, stand. fin. 24 ga. (See Tech Specs.)

55 SF

Install Steel roof flat profile, 1-3/4" stand.

seams, 12" w, stand. fin. 24 ga.

55 SF

(See Tech Specs.)

Remove and Dispose Aluminum roofing, corrugated, painted, .032" thick (See Tech Specs.) 55 SF

Install Aluminum roofing, corrugated, painted, .032" thick (See Tech 55 SF

Specs.)

Remove and Dispose Asphalt shingles, #15 felt underlayment (See Tech Specs.) 55 SF

1101 Install Asphalt shingles, #15 felt underlayment (See Tech Specs.)

55 SF

Remove and Dispose Asphalt shingles, std strip shingles, inorganic, class A, 210-235 lb/sq (See Tech Specs.)

55 SF

Install Asphalt shingles, std strip shingles, inorganic, class A, 55 SF

210-235 lb/sq (See Tech Specs.)

Remove and Dispose Steel roofing, ridge, galvanized, 20" wide (See Tech Specs.) 55 LF

1104 Install Steel roofing, ridge, galvanized, 20" wide (See Tech Specs.)

55 LF

Remove and Dispose Fascia, aluminum, .032" thick, colored, NO furring included (See Tech Specs.) 55 SF

Install Fascia, aluminum, .032" thick, colored, NO furring included

55 SF

1106 (See Tech Specs.)

Remove and Dispose Fascia, steel, galv and enameled, stock, NO furring, 55 SF

1107 long panels (See Tech Specs.)

Install Fascia, steel, galv and enameled, stock, NO furring, 55 SF

1108 long panels (See Tech Specs.)

Remove and Dispose Gutters, aluminum, 5" box type, enameled (See Tech Specs.)

160 LF

Install Gutters, aluminum, 5" box type, enameled (See Tech Specs.) 160 LF

Remove and Dispose Gutters, alum, 5" x 6" comb fascia & gutter, .032" thick, 160 LF enameled (See Tech Specs.)

Install Gutters, alum, 5" x 6" comb fascia & gutter, .032" thick, 160 LF enameled (See Tech Specs.)

Remove and Dispose Gutters, steel, galv, half round or box, 28 ga, 5" 104 LF wide, enameled (See Tech Specs.)

Install Gutters, steel, galv, half round or box, 28 ga, 5" wide, 104 LF enameled (See Tech Specs.)

Remove and Dispose Gravel stop, galv steel, 6" face height (See Tech Specs.) 104 LF

Install Gravel stop, galv steel, 6" face height (See Tech Specs.) 104 LF

1116 Remove and Dispose Gravel stop, aluminum, .050" thick, 6" height, painted (See Tech Specs.) 104 LF

Install Gravel stop, aluminum, .050" thick, 6" height, painted (See Tech Specs.) 104 LF

Remove and Dispose Gravel Gravel stop, aluminum, .050" thick, 8" height, painted (See Tech Specs.)

104 LF

Install Gravel stop, aluminum, .050" thick, 8" height, painted (See Tech Specs.) 104 LF

Remove and Dispose Gravel Gravel Gutters, aluminum, 5" box type, .032" thick, plain (See Tech Specs.)

160 LF

Install Gutters, aluminum, 5" box type, .032" thick, plain (See Tech Specs.) 160 LF

1120 LF

1121 Install Gutters, steel, galv, half round or box, 28 ga, 5" wide, plain (See Tech Specs.) 160 LF

Remove and Dispose Gutters, steel, galv, half round or

Remove and Dispose Gravel stop, aluminum, .050" thick, 6" height, duranodic finish 104 LF

1122 (See Tech Specs.)

Install Gravel stop, aluminum, .050" thick, 6" height, duranodic finish

104 LF

1123 (See Tech Specs.)

Remove and Dispose Gravel stop, aluminum, .050" thick, 8" height, duranodic finish (See Tech Specs.)

104 LF

Install Gravel stop, aluminum, .050" thick, 8" height, duranodic finish

104 LF

(See Tech Specs.)

Remove and Dispose Downspouts, aluminum 3" x 4", .024" thick, enameled (See Tech Specs.) 60 LF

Install Downspouts, aluminum 3" x 4", .024" thick, enameled (See Tech Specs.) 60 LF

Remove and Dispose Downspouts, steel, rectangular, plain, 28 ga, galvanized, 3" x 4" (See Tech Specs.)

60 LF

Install Downspouts, steel, rectangular, plain, 28 ga, galvanized, 60 LF

1128 3" x 4" (See Tech Specs.)

Remove and Dispose Downspouts, steel, rect, epoxy painted, 24 ga, corrugated, 60 LF

1129 3" x 4" (See Tech Specs.)

Install Downspouts, steel, rect, epoxy painted, 24 ga, corrugated, 60 LF

1130 3" x 4" (See Tech Specs.)

1131 Remove and Dispose Drip edge, aluminum, .016" thick, 5" wide, mill finish (See Tech Specs.) 60 LF

Install Drip edge, aluminum, .016" thick, 5" wide, mill finish (See Tech Specs.)

60 LF

Remove and Dispose and Dispose Drip edge, aluminum, .016" thick, 5" wide, white finish (See Tech Specs.)

60 LF

1133 Install Drip edge, aluminum, .016" thick, 5" wide, white finish (See Tech Specs.)

60 LF

Remove and Dispose Drip edge, galvanized, 5" wide, mill finish (See Tech Specs.) 60 LF

Install Drip edge, galvanized, 5" wide, mill finish (See Tech Specs.)

60 LF

Remove and Dispose Elbows, aluminum, 3" x 4", .025" thick, embossed (See Tech Specs.) 26 EA

1136 Install Elbows, aluminum, 3" x 4", .025" thick, embossed (See Tech Specs.)

26 EA

Remove and Dispose Elbows, aluminum, 3" x 4", .025" thick, enameled (See Tech Specs.) 26 EA

Install Elbows, aluminum, 3" x 4", .025" thick, enameled (See Tech Specs.)

26 EA

1138 Remove and Dispose Flashing, aluminum, mill finish, .032" thick (See Tech Specs.)

90 SF

Install Flashing, aluminum, mill finish, .032" thick (See Tech Specs.)

90 SF

Remove and Dispose Vent flashing, aluminum with lead ring, 2" pipe (See Tech Specs.) 9 EA

1140 Install Vent flashing, aluminum with lead ring, 2" pipe (See Tech Specs.)

9 EA

Remove and Dispose Vent flashing, aluminum with lead ring, 3" pipe (See Tech Specs.) 9 EA

Install Vent flashing, aluminum with lead ring, 3" pipe (See Tech Specs.) 9 EA

Remove and Dispose Vent flashing, aluminum with lead ring, 4" pipe (See Tech Specs.) 9 EA

1143 Install Vent flashing, aluminum with lead ring, 4" pipe (See Tech Specs.)

9 EA

Remove and Dispose Vent flashing, aluminum with lead ring, 1-1/2" pipe (See Tech Specs.) 9 EA

Install Vent flashing, aluminum with lead ring, 1-1/2" pipe (See Tech

9 EA

Specs.)

Remove and Dispose Reglet, counter flashing for above, 12" wide, .032" aluminum (See Tech Specs.) 44 LF

Install Reglet, counter flashing for above, 12" wide, .032" aluminum 44 LF

(See Tech Specs.)

Remove and Dispose Roof vents, mushroom for built-up roofs, PVC, 6"

16 EA

high

Install Roof vents, mushroom for built-up roofs, PVC, 6" high

16 EA

Remove and Dispose Vents, one-way, aluminum (See Tech Specs.) 16 EA

Install Vents, one-way, aluminum (See Tech Specs.) 16 EA

Remove and Dispose Drains-scppr flr, oblique strn-CI, 6"x7" top, 2", 3"&4" pipe size (See Tech Specs.)

4 EA

Install Drains-scppr flr, oblique strn-CI, 6"x7" top, 2", 3"&4" pipe size 4 EA

(See Tech Specs.)

Remove and Dispose Drains, roof, flat metal deck, C.I. body, 12" C.I. 4 EA dome, 3" pipe size (See Tech Specs.)

Install Drains, roof, flat metal deck, C.I. body, 12" C.I. dome, 4 EA

3" pipe size (See Tech Specs.)

Remove and Dispose Drains, roof, flat mtl deck, galvanized body, 12"CI dome, 6" pipe (See Tech Specs.)

4 EA

1155 Install Drains, roof, flat mtl deck, galvanized body, 12"CI dome, 6" pipe

4 EA

(See Tech Specs.)

Remove and Dispose Drains, cornice, C.I., 45< or 90< outlet, 3" and 4" pipe size (See Tech Specs.) 4 EA

1157 Install Drains, cornice, C.I., 45< or 90< outlet, 3" and 4" pipe size

4 EA

(See Tech Specs.)

Remove and Dispose Drains, cornice, C.I., for galvanized body, 3" and 4" pipe size (See Tech Specs.) 4 EA

Install Drains, cornice, C.I., for galvanized body, 3" and 4" pipe size

4 EA

1159 (See Tech Specs.)

Remove and Dispose Elastomeric rfg,poly spray-on W/20mil silicone rbr ctg , 3"thk,r21,min (See Tech Specs.)

1,600 SF

Install Elastomeric rfg,poly spray-on W/20mil silicone rbr ctg , 1,600 SF

1161 3"thk,r21,min (See Tech Specs.)

Remove and Dispose Built-up rfg,asph fl CT W/gvl,ctd gl base sht,3ply gl,nailable dk (See Tech Specs.)

5,200 SF

Install Built-up rfg,asph fl CT W/gvl,ctd gl base sht,3ply gl,nailable dk 5,200 SF

(See Tech Specs.)

Remove and Dispose Built-up rfg,asph fl CT W/gvl,ctd gl base sht,4ply gl 5,200 SF fbr felt,mopped

Install Built-up rfg,asph fl CT W/gvl,ctd gl base sht,4ply gl 5,200 SF fbr felt,mopped

Remove and Dispose Cants, 4" x 4" treated timber, cut diagonally (See Tech Specs.) 90 LF

Install Cants, 4" x 4" treated timber, cut diagonally (See Tech Specs.) 90 LF

Remove and Dispose B247Single-ply membrane, EPDM, 60 mil, 0.40 PS, fully 5,200 SF adhered w/adhesive, w/4" seam tape (See Tech Specs.)

1168 Install B247Single-ply membrane, EPDM, 60 mil, 0.40 PS, fully

5,200 SF

adhered w/adhesive, w/4" seam tape (See Tech Specs.)

Remove and Dispose Mod bit rfng, SBS mod, gran surf cap sheet, poly rein, mppd, 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to

1,040 SF

deck w/asphalt primer (See Tech Specs.)

Install Mod bit rfng, SBS mod, gran surf cap sheet, poly rein, mppd, 1,040 SF

160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to

1171 deck w/asphalt primer (See Tech Specs.)

Remove and Dispose Mod bit, SBS mod, smooth surf cap sheet, glass fiber rein, mppd, 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped

1,040 SF

1172 to deck w/asphalt primer (See Tech Specs.)

Install Mod bit, SBS mod, smooth surf cap sheet, glass fiber rein, mppd, 1,040 SF

160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to deck w/asphalt primer (See Tech Specs.)

Remove and Dispose Mod bit, APP mod, gran surface cap sheet, poly 1,040 SF rein, torched, 180 mils w/base sheet, #15 Glass Fiber Felt fully mopped to deck w/asphalt primer (See Tech Specs.)

Install Mod bit, APP mod, gran surface cap sheet, poly rein, 1,040 SF

1176 torched, 180 mils w/base sheet, #15 Glass Fiber Felt fully mopped to deck w/asphalt primer (See Tech Specs.)

Remove and Dispose Mod bit, APP mod, smooth surf cap sheet, poly rein, torched, 1,040 SF

160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to deck w/asphalt primer (See Tech Specs.)

Install Mod bit, APP mod, smooth surf cap sheet, poly rein, torched, 1,040 SF

160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to

1179 deck w/asphalt primer (See Tech Specs.)

Remove and Dispose Roof coatings, asphalt primer, 5 gallon (See Tech Specs.)

20,000 SF

Install Roof coatings, asphalt primer, 5 gallon (See Tech Specs.)

20,000 SF

Remove and Dispose Bituminous asphalt coating, with fibers, troweled on, 1/2" thick (See Tech Specs.)

2,600 SF

Install Bituminous asphalt coating, with fibers, troweled on, 1/2" thick 2,600 SF

(See Tech Specs.)

Remove and DisposeBuilt-up rfg,asph fl CT,ctd gl fbr base sht,3 plies,on nailable dks (See Tech Specs.) 2,000 SF

Install Built-up rfg,asph fl CT,ctd gl fbr base sht,3 plies,on nailable dks

2,000 SF

1184 (See Tech Specs.)

Remove and Dispose Built-up rfg,asph fl CT,ctd gl fbr base sht,4ply gl fbr felt,mopped (See Tech Specs.)

2,000 SF

Install Built-up rfg,asph fl CT,ctd gl fbr base sht,4ply gl fbr felt,mopped

2,000 SF

1186 (See Tech Specs.)

Remove and Dispose Rubber coating, silicone or stearate, sprayed on CMU, 2 coats (See Tech Specs.) 1,040 SF

Install Rubber coating, silicone or stearate, sprayed on CMU, 2 coats 1,040 SF

(See Tech Specs.)

Remove and Dispose Pitch Pockets, side extenders, 6" (See Tech 18 EA

Specs.)

Install Pitch Pockets, side extenders, 6" (See Tech Specs.) 18 EA

Remove and Dispose Pitch Pockets, adjustable, 4" to 7", welded corners, 4" deep (See Tech Specs.) 18 EA

1191 Install Pitch Pockets, adjustable, 4" to 7", welded corners, 4" deep 18 EA

(See Tech Specs.)

Remove and Dispose Walkway for BUR, asph impregnated, 3' x 3' x 3/4" thk (See Tech Specs.) 700 SF

Install Walkway for BUR, asph impregnated, 3' x 3' x 3/4" thk (See Tech Specs.) 700 SF

Remove and Dispose Caulking & sealants, polyurethane, 1 or 2 component, bulk (See Tech Specs.)

90 LF

1194 Install Caulking & sealants, polyurethane, 1 or 2 component, bulk

90 LF

(See Tech Specs.)

Remove and Dispose Caulking and sealants, silicone rubber, cartridges (See Tech Specs.) 90 LF

1196 Install Caulking and sealants, silicone rubber, cartridges (See Tech 90 LF

Specs.)

Remove and Dispose Caulking and sealants, resin epoxy coating, 2 component, heavy duty (See Tech Specs.)

90 LF

Install Caulking and sealants, resin epoxy coating, 2 component, heavy

90 LF

1198 duty (See Tech Specs.)

Remove and Dispose Caulking and sealants, neoprene gaskets, closed cell, 1/4" x 3/4" (See Tech Specs.)

90 LF

Install Caulking and sealants, neoprene gaskets, closed cell, 1/4" x 3/4"

90 LF

(See Tech Specs.)

Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 6" (See Tech Specs.)

90 LF

Install Framing, miscellaneous,…