Attachment 1.1 DLA HQC HVAC Equipment List.xlsx
XLSX spreadsheet 41 KB Posted
- Attached to
- BCS/UCS DLA ENTERPRISE REQUIREMENT
- Solicitation number
- SP470525R002026
- Issued by
-
Defense Logistics Agency
About this file
This is an equipment list spreadsheet detailing HVAC and control systems across multiple DLA facilities. The document contains three detailed tables listing equipment quantities for HVACR maintenance equipment, HVACR control systems, and meter systems at five DLA locations: Ft. Belvoir, San Joaquin, Richmond, Columbus, and Susquehanna.
The inventory includes extensive HVAC equipment such as 1,641 rooftop units, 288 split systems, 285 air handling units, 40 chillers, 685 pumps, 67 boilers, 1,685 VAV boxes, 2,006 unit heaters, and 7,100 operators. Control systems include building level controllers, field level controllers, sensors, and actuators totaling over 23,373 devices. Metering systems cover steam, water, electric, and natural gas measurements. The equipment operates on various power configurations (single and three-phase) and utilizes multiple control protocols including BACnet, LON, MODBUS, and proprietary systems.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 0002_Questions_Answers_24 JAN 2025_FINAL.xlsx | XLSX spreadsheet | |
| Attachment 3 ABCS UCS - Cross Reference Matrix12.19.xlsx | XLSX spreadsheet | |
| Attachment 1.3 TO IDIQ Facility Equipment List _DDSP_.xlsx | XLSX spreadsheet | |
| Attachment 1.5 TO_and IDIQ Equipment List for DDJC.xlsx | XLSX spreadsheet | |
| Attachment 5 - Contractor NDA.pdf | ||
| Attachment 1.2 TO_and_IDIQ Equipment List Richmond.xlsx | XLSX spreadsheet | |
| Attachment 1A - Draft BCS_UCS PWS HQ Task Order 12.17.pdf | ||
| DFAFT RFP SP4705-25-R-2026_BCS_UCS_.pdf | ||
| Attachment 4 - Key Personnel Resume Template.pdf | ||
| Attachment 2A - Pricing Sheet_BCS UCS TO Schedule B.xlsx | XLSX spreadsheet | |
| Attachment 2 - Pricing Sheet_BCS UCS IDIQ Schedule B R1.xlsx | XLSX spreadsheet | |
| Attachment 1.4 TO IDIQ Facility Equipment List for Columbus.xlsx | XLSX spreadsheet | |
| Attachment 1 - Draft BCS_UCS PWS HQ IDIQ 12.17.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Table 1
| Table - 1 Typical Building Equipment List for HVACR Maintenance | |||||||||||||||||||||||||||||||
| Equipment Types | Fuel / Water Types | Power - V (phase) | Controls | Quantity of Assets (estimated) | |||||||||||||||||||||||||||
| Natural Gas | Fuel Oil | Electric | Hot Water | Domestic Water | Chilled Water | Direct Expansion (DX) | Water Chemistry Chemicals | Steam | Water Source | Ground Coupled | 0-24 V (1) | 120 (1) | 208 (1) | 240 (1) | 277 (1) | 208 (3) | 480 (3) | 4160 (3) | 15K (3) | Pulse | LON | BACnet | MODBUS | Other (N2, manufacturer specific, standalone) | Ethernet (IP) | Ft. Belvoir | San Joaquin | Richmond | Columbus | Susquehanna | |
| HVACR Equipment | |||||||||||||||||||||||||||||||
| Air Distribution units | 154 | 460 | 1027 | ||||||||||||||||||||||||||||
| Rooftop Units | X | X | X | X | X | X | X | X | X | 16 | 154 | 100 | |||||||||||||||||||
| Split Systems | X | X | X | X | X | X | X | X | 6 | 45 | 237 | ||||||||||||||||||||
| Packaged Units (e.g. - PTAC) | X | X | X | X | X | X | X | X | X | X | 16 | 35 | |||||||||||||||||||
| Air Handling units | X | X | X | X | X | X | X | X | X | X | 116 | 22 | 147 | ||||||||||||||||||
| Computer Room Air Conditioners (CRAC) | X | X | X | X | X | X | X | 9 | 8 | 23 | |||||||||||||||||||||
| Energy Recovery Ventilator (ERVs) | 9 | 0 | 20 | ||||||||||||||||||||||||||||
| Dedicated Outdoor Air System (DOAS) | X | X | X | X | X | 3 | 2 | 2 | |||||||||||||||||||||||
| Make up air Units | X | X | X | X | X | X | X | 3 | 14 | 34 | |||||||||||||||||||||
| Heat pumps / WSHP | X | X | X | X | X | X | X | 7 | 45 | 451 | |||||||||||||||||||||
| Evaporative Coolers | 0 | 170 | 0 | ||||||||||||||||||||||||||||
| Chillers | 10 | 5 | 6 | ||||||||||||||||||||||||||||
| Water Cooled | X | X | X | X | X | 7 | 0 | 2 | |||||||||||||||||||||||
| Air Cooled | X | X | X | X | 2 | 5 | 4 | ||||||||||||||||||||||||
| Cooling towers | 7 | 0 | 8 | ||||||||||||||||||||||||||||
| Open loop towers | X | X | X | X | 7 | 0 | 2 | ||||||||||||||||||||||||
| Closed loop towers | 0 | 0 | 6 | ||||||||||||||||||||||||||||
| Pumps (all sizes / types) | X | X | X | X | X | X | X | X | 160 | 250 | 275 | ||||||||||||||||||||
| Fuel Oil | 5 | 8 | |||||||||||||||||||||||||||||
| Water | 155 | 267 | |||||||||||||||||||||||||||||
| Boilers | 6 | 17 | 44 | ||||||||||||||||||||||||||||
| Condensing | x | X | X | X | X | 4 | 0 | 6 | |||||||||||||||||||||||
| Noncondensing | x | X | X | X | X | 2 | 17 | 38 | |||||||||||||||||||||||
| MicroTurbines | 0 | 0 | 6 | ||||||||||||||||||||||||||||
| Variable Air Volume Boxes / Reheat | 1510 | 26 | 149 | ||||||||||||||||||||||||||||
| Shutoff | X | X | X | X | X | X | X | 950 | 0 | 84 | |||||||||||||||||||||
| Fan Powered | X | X | X | X | X | X | X | 560 | 26 | 65 | |||||||||||||||||||||
| Unit heaters | 116 | 462 | 1428 | ||||||||||||||||||||||||||||
| Cabinet Unit heater | X | X | X | X | X | 26 | 26 | 10 | |||||||||||||||||||||||
| Unit ventilator | X | X | X | X | X | 64 | 0 | 2 | |||||||||||||||||||||||
| Unit Heaters | X | X | X | X | X | X | 26 | 436 | 1416 | ||||||||||||||||||||||
| Humidifiers | 1 | 10 | 19 | ||||||||||||||||||||||||||||
| Electric | X | X | 1 | 10 | 6 | ||||||||||||||||||||||||||
| Steam | 0 | 0 | 13 | ||||||||||||||||||||||||||||
| Operators | 4600 | 1000 | 1500 | ||||||||||||||||||||||||||||
| Valve | X | X | X | X | 2000 | 500 | 800 | ||||||||||||||||||||||||
| Damper | X | X | X | X | 2600 | 500 | 700 | ||||||||||||||||||||||||
| Fans | 284 | 450 | 816 | ||||||||||||||||||||||||||||
| Ventilation (all sizes / types) | X | X | X | X | X | X | 284 | 450 | 812 | ||||||||||||||||||||||
| Process (all sizes / types) | 0 | 0 | 14 | ||||||||||||||||||||||||||||
| Variable Frequency Drives | X | X | X | 137 | 45 | 150 | |||||||||||||||||||||||||
| Kitchen Hood and MAU | X | X | X | X | X | X | 2 | 6 | 6 | ||||||||||||||||||||||
| Heat Exchangers and Steam Converters | X | X | X | X | 2 | 5 | 46 | ||||||||||||||||||||||||
| Chemical Injection Systems | X | X | X | 2 | 2 | 4 | |||||||||||||||||||||||||
| Walk in Refrigeration and Freezers | X | X | X | 3 | 5 | 8 | |||||||||||||||||||||||||
| Special ventilation systems: refrigerant and vehicle exhaust (CO, NO2) | 3 | 2 | 4 |
Total Devices 13875 5175 0 0 10800
Table 2
| Table - 2 Typical Building Equipment List for HVACR Control Systems | |||||||||||||||||||||||||||||||
| Equipment Types | Fuel / Water Types | Power - V (phase) | Controls | Quantity of Assets (estimated) | |||||||||||||||||||||||||||
| Natural Gas | Fuel Oil | Electric | Hot Water | Domestic Water | Chilled Water | Direct Expansion (DX) | Water Chemistry Chemicals | Steam | Water Source | Ground Coupled | 0-24 V (1) | 120 (1) | 208 (1) | 240 (1) | 277 (1) | 208 (3) | 480 (3) | 4160 (3) | 15K (3) | Pulse | LON | BACnet | MODBUS | Other (N2, manufacturer specific, standalone) | Ethernet (IP) | Ft. Belvoir | San Joaquin | Richmond | Columbus | Susquehanna | |
| HVACR CONTROLS | |||||||||||||||||||||||||||||||
| Site Control Servers | X | X | X | X | X | 2 | 3 | ||||||||||||||||||||||||
| Building Level Controllers | X | X | X | X | X | 46 | 10 | 45 | |||||||||||||||||||||||
| Field Level Controllers | X | X | X | X | 300 | 600 | 1000 | ||||||||||||||||||||||||
| Equipment specific Controllers or NICs | X | X | X | X | 2485 | 250 | 500 | ||||||||||||||||||||||||
| Sensors(temperature, humidity, flow, etc.) | X | X | X | 6000 | 2000 | 4000 | |||||||||||||||||||||||||
| Actuators (Valves/dampers) | X | X | X | X | 4600 | 1500 | |||||||||||||||||||||||||
| Relay system (RIB) | X | X | X | X | X | 25 | |||||||||||||||||||||||||
| Media Converters | X | X | X | 2 | 5 |
Total Devices 13435 2860 0 0 7078
Table 3
| Table - 3 Typical Building Equipment List for Meter Systems | |||||||||||||||||||||||||||||||
| Equipment Types | Fuel / Water Types | Power - V (phase) | Controls | Quantity of Assets (estimated) | |||||||||||||||||||||||||||
| Natural Gas | Fuel Oil | Electric | Hot Water | Domestic Water | Chilled Water | Direct Expansion (DX) | Water Chemistry Chemicals | Steam | Water Source | Ground Coupled | 0-24 V (1) | 120 (1) | 208 (1) | 240 (1) | 277 (1) | 208 (3) | 480 (3) | 4160 (3) | 15K (3) | Pulse | LON | BACnet | MODBUS | Other (N2, manufacturer specific, standalone) | Ethernet (IP) | Ft. Belvoir | San Joaquin | Richmond | Columbus | Susquehanna | |
| Meters | |||||||||||||||||||||||||||||||
| Site Control Servers | 1 | ||||||||||||||||||||||||||||||
| Media Converters / Building Controllers | 2 | 0 | 45 | ||||||||||||||||||||||||||||
| Steam | X | X | X | X | X | 0 | 0 | 21 | |||||||||||||||||||||||
| Water | X | X | X | X | X | X | 20 | 3 | 51 | ||||||||||||||||||||||
| Electric | X | X | X | X | X | 20 | 75 | 51 | |||||||||||||||||||||||
| Natural Gas | 14 | 40 | 46 | ||||||||||||||||||||||||||||
| BTU Meter |
Total Devices 57 118 0 0 214