This is a solicitation for a construction contract to repair Building 2000 at Forbes Field in Topeka, Kansas. The project magnitude is between $1,000,000 and $5,000,000, and funds are anticipated to become available by September 30, 2021. The work includes remodeling and repairs to the medical and communication building. The solicitation is set aside for total small businesses. Award will be made based on best value as outlined in the solicitation. The contract is being solicited by the Department of the Army Kansas Army National Guard as project number GUQE162200. The NAICS code is 236220. Responses are due as indicated in the solicitation documents.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING 2000
S W
T O
P E
K A
B L V
D
SW 57th STREET
COYOTE DRIVE
BASE ENTRY;
GUARD STATION
CONTRACTOR PARKING
1) GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY
DISCREPANCIES BETWEEN SPECIFICATIONS AND DRAWINGS, BETWEEN
MULTIPLE SPECIFICATION SECTIONS AND/OR BETWEEN MULTIPLE DRAWINGS.
THE ARCHITECT WILL DETERMINE WHICH SHALL GOVERN.
2) GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CONDITIONS OF THE JOB SITE INCLUDING UTILITIES AND EXISTING
STRUCTURES PRIOR TO BEGINNING WORK AND REPORT ANY
DISCREPANCIES TO THE ARCHITECT.
3) GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR STABILITY OF THE
STRUCTURE DURING CONSTRUCTION INCLUDING ALL SHORING AND BRACING
REQUIRED TO RESIST REQUIRED VERTICAL AND LATERAL FORCES.
4) ALL ARCHITECTURAL FLOOR PLAN DIMENSIONS ARE FROM FACE OF
CONCRETE, MASONRY AND FINISHED DRYWALL.
5) ANY DAMAGE THAT OCCURS DUE TO CONSTRUCTION INCLUDING BUT NOT
LIMITED TO FINISHES SHALL BE REPAIRED TO THE SATISFACTION OF THE
OWNER AND ARCHITECT AT THE CONTRACTORS EXPENSE.
6) NEW FIRE SPRINKLER SYSTEM WILL REQUIRE REMOVAL & REINSTALLATION
OF EXISTING CEILING TILE & GRID SYSTEM. PROVIDE AS NECESSARY &
COORDINATE WITH FIRE SPRINKLER CONTRACTOR. ANY TILE OR GRID
DAMAGED BY THIS WORK SHALL BE REPLACED WITH NEW.
SECTION MARK:
1 = DETAIL NUMBER
A101 = SHEET NUMBER
BUILDING
LEVEL 1
0'-0"
WALL
A20 6
EXISTING
NEW
EXPANSION JOINT
CONTROL JOINT
FLOOR COVERING CHANGE
SAWCUT CONCRETE FLOOR JOINTS-
REFERENCE STRUCTURAL FOR COMPLETE LOCATIONS
NEW FINISH SPOT ELEVATIONS IN FEET AND INCHES
(OR ON SITE PLAN IN FEET AND DECIMALS)
EXISTING SPOT ELEVATION
DOOR MARK - REFERENCE DOOR AND
FRAME SCHEDULE
LOCATION OF SYMBOL ON PAIR OF
DOORS INDICATES THE ACTIVE LEAF
PLAN NOTES
ELEVATION MARK IN FEET AND INCHES
A20
(6
F C
C J
E J
S C
100'-0"
100'-0"
A101
INTERIOR ELEVATION MARKER:
A202 = SHEET NUMBER
6 = DETAIL NUMBER
BUILDING ELEVATION MARKER:
A201 = SHEET NUMBER
6 = DETAIL NUMBER
DETAIL MARKS:
1 = DETAIL NUMBER
A101 = SHEET NUMBER
SIM = SIMILAR
A101
SIM
LIGHT WEIGHT OR NORMAL WEIGHT
CONCRETE MASONRY UNIT AS NOTED
INSULATION - FOUNDAITON
INSULATION - WALL
STEEL
WOOD FRAMING OR BLOCKING
INSULATION - ROOF
INSULATION - BATT
GLASS (ELEVATION/SECTION)
ACOUSTICAL CEILING PANEL OR TILE
AIR BARRIER ELEVATION
GYPSUM BOARD PARTITION:
3 5/8" METAL STUDS @ 16" OC - COVER EACH
SIDE WITH 5/8" TYPE X GYPSUM BOARDS.
EXTEND PARTITION TO UNDERSIDE OF DECK
AND FILL VOIDS WITH ACOUSTICAL INSULATION.
G5a
GYPSUM
A301
A301
A301
A301
A301
A301
A301
A301
A301
A301
A301
A301
A301
A301
A301
A301
A301
A301
A301
A301
A301
A301
INSTALL
088000-1 TO
ALL PANES.
117'-6 5/8" ±
7' -5
/1
7' -6
/8
88'-2 7/8" ±
19'-8 3/8" ±
/8
REF A101 FOR PLAN NOTES.
A R
C H
I T
E C
T S
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
W
O T H
S T
S T E
O V E R
L A N
D P
A R
K K
A N
S A S
P
.6
.5 w w w .h tk a rc h it e c ts
.c o m
S
K A
N S A
S A
V E
S U
IT
E
T O
P E K
A
K A
N S
A S
P
.2
.5
/1
/2
:3 :1
P
M C
U se rs
\z js
\D o c um e nt s\ B ld g
E ne rg y R e p a ir v za c hs ne th e n1
.r vt
G101
B U
IL
D
IN
G
R
E P
A
IR
M E D
IC
A
L A
N D
C O
M M
U N
IC
A
T
IO
N S
H T K
A rc h it e c ts
TITLE SHEET
05/01/2020
GUQE162200
FO
R B
E S
F
IE
L D
T O
P E K
A K
S
ORIGINAL CONTRACT DOCUMENTS
BUILDING 2000 REPAIR MEDICAL AND COMMUNICATIONS
SHEET INDEX
OWNER
Kansas Air National Guard
FORBES FIELD
TOPEKA, KS
PROJECT CONTACT
Capt. Jarrod Brunkow jarrod.a.brunkow.mil@mail.mil 785-861-4402
ARCHITECT
HTK Architects, Inc.
900 S. Kansas Ave., Suite 200 Topeka, KS 66612
PROJECT CONTACT
ZACH SNETHEN
zjs@htkarchitects.net
(785) 266-5373
MECHANICAL, ELECTRICAL,
PLUMBING ENGINEER
LATIMER, SOMMERS, &
ASSOCIATES
3639 SW SUMMERFIELD DR.
STUITE A
TOPEKA, KS 66614
PROJECT CONTACT
ALEX KARAM
akaram@lsapa.com
(785) 233-3232
PROJECT CONTACT
INFORMATION
G101 TITLE SHEET
ARCHITECTURAL
A101 FLOOR PLAN, ROOF PLAN, AND DOOR SCHEDULE
A201 BUILDING ELEVATIONS
A301 DETAILS
SITE LOCATION MAP
GUQE162200
FORBES FIELD, TOPEKA, KANSAS
GENERAL NOTES
GRAPHIC SYMBOLS
MATERIALS
MECHANICAL
ME001 GENERAL MECHANICAL / ELECTRICAL NOTES
ME101 TEMPERATURE CONTROLS
ME102 TEMPERATURE CONTROLS
ME103 PARTIAL FLOOR PLANS - HVAC DEMOLITION
ME104 PARTIAL FLOOR PLANS - MECHANICAL/ELECTRICAL DEMOLITION
M101 FLOOR PLAN - HVAC
M102 FLOOR PLAN - HVAC PIPING
M201 MECHANICAL SCHEMATICS
M202 MECHANICAL DETAILS
M203 MECHANICAL SCHEDULES
ELECTRICAL
E101 FLOOR PLAN - POWER
E102 PARTIAL FLOOR PLANS - POWER
E201 FLOOR PLAN - LIGHTING
NORTH
PARTITION SCHEDULE
1/16" = 1'-0"2
ROOF PLAN
PLUMBING
P101 PARTIAL FLOOR PLAN - PLUMBING
MP101 PARTIAL FLOOR PLANS - HVAC
FIRE PROTECTION
FA101 FIRE ALARM PLAN
FS101 FIRE SPRINKLER PLAN
FS102 PARTIAL FLOOR PLAN - FIRE SUPPRESSION
A2011
A201
A201
A201
MECH./ELEC.
A127
COMM. STOR.
A126
VIDEO/PORTRAIT
STUDIO
A122
COMM.
MAINTENANCE
A125
OFF.
A123
CORR.
A105
OFF.
A109
VAULT
A108
DOC. DEST.
A112
J.
A124
COMM./TRAINING
RM
A113
VEST
A106
FRAME/TELE.
A114
PRINTING
A111 MAIL
A110a
STOR.
A110b
INFO. MANAGE.
A110
OFF.
A107d
OFF.
A107c
OFF.
A107b
LOBBY
A102
VEST.
A100
VEST.
A104
CORR.
A156
VEST
A157
CLRM
A134
SUPPORT
A118
OFF.
A118a
OFF.
A119
LAB.
A129a
ADMIN.
A144
STOR.
A141
OFF.
A135CLRM
A117
EXAM
A154
HEADEND
MAINTENANCE
A121
XRAY
A146
XRAY
A145
OFF
A137
ADMIN.
A140
ADMIN.
A138
DENTAL OPER.
A139 LAB.
A142
MECH.
A155
ADMIN.
A136
WOMEN
A116
MEN
A115
T.
A143
J.
A131
T.
A132
EXAM
A153
EXAM
A152
EXAM
A151
EXAM
A150
EXAM
A148
AUDIO
A149
OFF.
A133
OFF.
A133b
OFF.
A133a
CONF.
A128b
OFF.
A128a
OFF.
A107a
ADMIN.
A128
ENG.
SERVICES/HEALTH
A129
OFF.
A128d
OFF.
A128c
ADMIN.
A130
OPEN OFF.
A107
VIDEO CONTROL
A120
STOR.
A130a
FIRST AID
A147
A133.2
A130a
EXTERIOR
MECH.
YARD
3 3 3
3 3
6 6
A301
A301
A301
A301
A101
A101
A114b
A a
A a
A c
A155
A157b A157a
A c
A d
A b
A a
A110a
A106a A106b
A127
A b
A a
A c
A d
* Field verify conditions at all exist. openings & modify as req'd to fit.
Field verify existing door dimensions
* Letters in parentheses ( ) A, B, C, D, E, & F at top of various columns in the schedule are for column identification & are clarified as follows:
(B) For DOOR MATERIAL AND FRAME MATERIAL:
HM = Hollow Metal A = Aluminum
SCHEDULE NOTES:
1. CLEAN, PRIME, AND PAINT ENTIRE (ALL SIDES, ALL EDGES)
OF EXISTING DOOR FRAME.
2. REMOVE EXISTING SEALS, WEATHERSTRIPPING, SECURITY
PLATE, DOOR SWEEP, AND THRESHOLD. REPLACE ITEMS
WITH NEW HARDWARE AS SPECIFIED. INSTALL IN A MANNER
TO CREATE AN AIR TIGHT SEAL AROUND ENTIRE OPENING.
FIELD VERIFY EXISTING HARDWARE TO MATCH NEW
EXCEPT SECURITY ASTRAGAL. SEE 9A301 FOR SECURITY
ASTRAGAL DETAIL. SEE ATTACHED PICTURE 3A101 FOR
EXISTING CONDITIONS.
3. SEE DETAIL 5A301.
4. REMOVE EXISTING SEALS AND DOOR SWEEP AND
SILENCERS W.O. REPLACE ITEMS WITH NEW HARDWARE AS
SPECIFIED. FIELD VERIFY EXISTING STYLE OF HARDWARE
TO MATCH NEW AND FIELD VERIFY EXISTING DOOR
MANUFACTURER.
5. SINGLE SWING DOOR.
6. PAIRED DOOR.
7. EXISTING DOOR & FRAME
8. MODIFY EXISTING FRAME AND PROVIDE NEW DOOR & PANEL
AS SHOWN IN DETAIL 2 BELOW.
9. A114A NOTE: REINSTALL PUSH BUTTON LOCKSET ON NEW
DOOR. SALVAGE FROM DOOR REMOVED.
10. SALVAGE DOOR HARDWARE FROM EXISTING DOOR.
GENERAL: COORDINATE WITH WORK SHOWN ON
STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL
DRAWINGS
INSTALL WINDOW FILM TO SKYLIGHTS BY
ALTERNATE NO. 2
INSTALL WINDOW FILM TO WINDOWS & DOORS
BY ALTERNATE NO. 2
FIX OPERABLE WINDOW CLOSED. REMOVE
LATCH HARDWARE & INSTALL COUNTERSUNK
FLAT HEAD SCREW TO SECURE WINDOWS.
MATCH SCREW TO FRAME COLOR.
REMOVE DOORS & HARDWARE. WELD IN
HORIZONTAL HEAD FRAME. INSTALL 1" INSULATED
METAL PANEL IN TRANSOM. INSTALL NEW DOORS
& HARDWARE. BY ALTERNATE NO. 3.
5 REMOVE ALL EXISTING CAULK BETWEEN
MASONRY & MASONRY. INSTALL NEW.
6 PRIME & PAINT EXPOSED STEEL LINTELS.
7 REMOVE & REPLACE SEALANT AROUND ALL
PIPE PENETRATIONS IN EXTERIOR WALLS.
WHERE NO SEALANT OCCURS, PROVIDE NEW.
8 PRIME & PAINT STEEL GATES. BY ALTERNATE NO. 3
ROOMS A113 & A114, PROVIDE NEW CEILING
TILE IN EXISTING GRID. MODIFY GRID AS
NECESSARY FOR NEW WALLS. REF ELEC FOR
LIGHTING AND GRID LAYOUT.
REMOVE GLAZING & REPLACE W/ SPANDREL
PANEL MATCHING EXISTING SPANDREL. INFILL
WINDOW OPENING W/ METAL STUD & GYPSUM
BOARD.
MODIFY DOOR OPENING TO BE SINGLE 42"
DOOR 7'-2" TALL W/ SOLID INSULATED METAL
PANEL SIDELITE MATCHING FRAME. BASE BID
12 EQUIPMENT BY OWNER.
REMOVE EXISTING CARPET. INSTALL NEW
CARPET. INSTALLER RESPONSIBLE FOR
MOVING FURNITURE NECESSARY FOR CARPET
INSTALL. BY ALTERNATE NO. 1.
13 NEW FRP DOOR PANEL ONLY. SALVAGE HARDWARE
FROM EXISTING. BY ALTERNATE NO. 3
1' -1
1/
24'-3 5/8" ±
/8
E Q
E Q
7"
/1
/1
7'-1 11/16" ± 3'-8" 3'-0" 3'-8" 6'-10"
1"
15'-3 5/8" 4'-2" 2'-4" 2'-6"
EXISTING ROOF
LADDER TO REMAIN
EXISTING CURB AROUND
CONDUITS TO REMAIN
E X
IS
T
IN
G
U P S
E L E C
T O
R E M
A
IN
ATT RELOCATE
CABINENT NEXT TO
EXISTING DMARK
ATT DMARK
PARTS
CABINETS
A T T
C A B
COMM./TRAINING
RM
A113
FRAME/TELE.
A114
OFF.
A109
INFO. MANAGE.
A110
PRINTING
A111
VEST
A106
CORR.
A105
COMM.
MAINTENANCE
A125
DOC. DEST.
A112
REMOVE EXISTING
WALL & DOOR
G5a
A a
A114b
MEN
A115
WOMEN
A116
SHOWER
SHOWER
5'-5 3/16" ±
/1
1/
1) REMOVE AND REPLACE ALL SEALANT AROUND
TOILET AND URINAL FIXTURES.
2) REMOVE AND REPLACE CAULKING AROUND
LAVATORIES.
3) REF. PLUMBING DRAWINGS FOR NEW FAUCETS AND
FLUSH VALVES.
4) REF PLUMBING FOR REMOVAL AND REPLACEMENT
OF SHOWER VALVES, CONTROL, AND HEADS.
5) REPAIR SHOWER WALLS AFTER NEW PLUMBING WORK
IS COMPLETE.
6) REF ELECTRICAL FOR NEW LIGHTING.
7) EXISTING TOILET PARTITIONS TO REMAIN.
8) EXISTING COUNTERTOPS TO REMAIN.
9) EXISTING TOILET ROOM ACCESSORIES TO REMAIN.
A114B
9' -4
6'-4" ±
3'-11" 2'-5"
7' -4
1" INSULATED
METAL PANEL
9' -4
PER SCHED.
7' -4
1" INSULATED
METAL PANEL
NEW HEAD FRAME
NEW FRP DOORS
MODIFY EXISTING
FRAME; OR
PROVIDE ENTIRE
NEW FRAME
MODIFY EXISTING
FRAME; OR
PROVIDE ENTIRE
NEW FRAME DETAIL 2
FRP DOOR PANEL
NEW HEAD FRAME
AND MULLION
A R
C H
I T
E C
T S
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
W
O T H
S T
S T E
O V E R
L A N
D P
A R
K K
A N
S A S
P
.6
.5 w w w .h tk a rc h it e c ts
.c o m
S
K A
N S A
S A
V E
S U
IT
E
T O
P E K
A
K A
N S
A S
P
.2
.5
/1
/2
:3 :1
P
M C
U se rs
\z js
\D o c um e nt s\ B ld g
E ne rg y R e p a ir v za c hs ne th e n1
.r vt
A101
B U
IL
D
IN
G
R
E P
A
IR
M E D
IC
A
L A
N D
C O
M M
U N
IC
A
T
IO
N S
H T K
A rc h it e c ts
FLOOR PLAN, ROOF PLAN, AND
DOOR SCHEDULE
05/01/2020
GUQE162200
FO
R B
E S
F
IE
L D
T O
P E K
A K
S
ORIGINAL CONTRACT DOCUMENTS
DOOR AND FRAME SCHEDULE
PLAN
MARK
DOOR FRAME
Notes
OPENING SIZE MATERIAL
(B)
MATERIAL
(B)W H
A100a 3'-0" 9'-2" A A 3, 4, 5, 7
A100b 3'-0" 9'-2" A A 3, 4, 5, 7
A100c 3'-0" 9'-2" A A 4, 5, 7
A100d 3'-0" 9'-2" A A 4, 5, 7
A104a 3'-0" 9'-2" A A 3, 4, 5, 7
A104b 3'-0" 9'-2" A A 3, 4, 5, 7
A104c 3'-0" 9'-2" A A 4, 5, 7
A104d 3'-0" 9'-2" A A 4, 5, 7
A106a 3'-0" 7'-2" A A 4, 5, 7
A106b 6'-0" 9'-2" A A 4, 6, 7
A110a 3'-0" 9'-2" A A 4, 5, 7
A114a 3'-6" 7'-2" S S 9
A114b 3'-6" 7'-2" FRP S 4, 5, 8
A122a 10'-0" 7'-2" FRP HM 1, 2, 6, 8
A126c 6'-0" 7'-2" FRP HM 1, 2, 6, 8
A127 6'-0" 7'-2" FRP HM 1, 2, 6, 8
A130a 6'-0" 7'-2" FRP HM 1, 2, 6, 8
A133.2 3'-0" 9'-2" A A 4, 5
A155 6'-0" 7'-2" FRP HM 1, 2, 6, 10
A157a 3'-6" 7'-2" A A 4, 5
A157b 3'-6" 7'-2" A A 4, 5
NO
R
TH
L A N
N O
R T H1/16" = 1'-0"1
ARCHITECTURAL FLOOR PLAN
DOOR & FRAME SCHEDULE NOTES PROJECT NOTES
1/4" = 1'-0"2
COMM ROOM
1/4" = 1'-0"3
RESTROOMS
RESTROOM NOTES
NO
R
TH
L A N
N O
R T H
A301
TYP.
A301
TYP.
A155A157a
A133.2 GATE
BEYOND
42 2
1 1
REF. 4A201 3
A301
TYP.
C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J.C.J.
C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J.
C.J.C.J.C.J.C.J.
C.J. C.J.
C.J. C.J.
C.J.C.J.
A301
TYP.
A301
TYP.
MECHANICAL
ENCLOSURE
SHOWN DASHED
FOR CLARITY
A104a A104b
A122a A126c
COLUMNS SHOWN
DASHED.
1 1 1
REF. 4A201
4 4 7
A301
TYP.
C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J.
C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J.
C.J. C.J. C.J. C.J.
C.J.
C.J. C.J.
C.J. C.J.
A301
TYP.
A301
TYP.
A100a A100b
1 1
COLUMNS SHOWN
DASHED FOR CLARITY
REF. 4A201
A301
TYP.
C.J. C.J.
C.J.
C.J. C.J. C.J. C.J. C.J.C.J.
C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J.C.J.
C.J. C.J.C.J.C.J. C.J.
C.J. C.J.
C.J.C.J.
C.J.C.J.
C.J.C.J.
C.J. C.J.C.J.C.J.
A301
TYP.
A301
TYP.
MECHANICAL ENCLOSURE
SHOWN DASHED FOR
CLARITY
A106a A127
7 2 3
REF. 4A201
A114b
C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J.
C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J.
C.J.
C.J.C.J.
C.J.C.J. C.J.
GENERAL: COORDINATE WITH WORK SHOWN ON
STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL
DRAWINGS
INSTALL WINDOW FILM TO SKYLIGHTS BY
ALTERNATE NO. 2
INSTALL WINDOW FILM TO WINDOWS & DOORS
BY ALTERNATE NO. 2
FIX OPERABLE WINDOW CLOSED. REMOVE
LATCH HARDWARE & INSTALL COUNTERSUNK
FLAT HEAD SCREW TO SECURE WINDOWS.
MATCH SCREW TO FRAME COLOR.
REMOVE DOORS & HARDWARE. WELD IN
HORIZONTAL HEAD FRAME. INSTALL 1" INSULATED
METAL PANEL IN TRANSOM. INSTALL NEW DOORS
& HARDWARE. BY ALTERNATE NO. 3.
5 REMOVE ALL EXISTING CAULK BETWEEN
MASONRY & MASONRY. INSTALL NEW.
6 PRIME & PAINT EXPOSED STEEL LINTELS.
7 REMOVE & REPLACE SEALANT AROUND ALL
PIPE PENETRATIONS IN EXTERIOR WALLS.
WHERE NO SEALANT OCCURS, PROVIDE NEW.
8 PRIME & PAINT STEEL GATES. BY ALTERNATE NO. 3
ROOMS A113 & A114, PROVIDE NEW CEILING
TILE IN EXISTING GRID. MODIFY GRID AS
NECESSARY FOR NEW WALLS. REF ELEC FOR
LIGHTING AND GRID LAYOUT.
REMOVE GLAZING & REPLACE W/ SPANDREL
PANEL MATCHING EXISTING SPANDREL. INFILL
WINDOW OPENING W/ METAL STUD & GYPSUM
BOARD.
MODIFY DOOR OPENING TO BE SINGLE 42"
DOOR 7'-2" TALL W/ SOLID INSULATED METAL
PANEL SIDELITE MATCHING FRAME. BASE BID
12 EQUIPMENT BY OWNER.
REMOVE EXISTING CARPET. INSTALL NEW
CARPET. INSTALLER RESPONSIBLE FOR
MOVING FURNITURE NECESSARY FOR CARPET
INSTALL. BY ALTERNATE NO. 1.
13 NEW FRP DOOR PANEL ONLY. SALVAGE HARDWARE
FROM EXISTING. BY ALTERNATE NO. 3
A R
C H
I T
E C
T S
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
W
O T H
S T
S T E
O V E R
L A N
D P
A R
K K
A N
S A S
P
.6
.5 w w w .h tk a rc h it e c ts
.c o m
S
K A
N S A
S A
V E
S U
IT
E
T O
P E K
A
K A
N S
A S
P
.2
.5
/1
/2
:3 :1
P
M C
U se rs
\z js
\D o c um e nt s\ B ld g
E ne rg y R e p a ir v za c hs ne th e n1
.r vt
A201
B U
IL
D
IN
G
R
E P
A
IR
M E D
IC
A
L A
N D
C O
M M
U N
IC
A
T
IO
N S
H T K
A rc h it e c ts
BUILDING ELEVATIONS
05/01/2020
GUQE162200
FO
R B
E S
F
IE
L D
T O
P E K
A K
S
ORIGINAL CONTRACT DOCUMENTS
1/8" = 1'-0"1
NORTH ELEVATION
1/8" = 1'-0"5
WEST ELEVATION
1/8" = 1'-0"4
EAST ELEVATION
1/8" = 1'-0"2
SOUTH ELEVATION
1/8" = 1'-0"3
ENTRY STOREFRONT
PROJECT NOTES
EXISTING SKYLIGHT SYSTEM
SHOWN SIMPLIFIED. FIELD
VERIFY ACTUAL CONDITIONS.
AIR BARRIER MEMBRANE
(SHOWN DASHED) WRAP TOP
OF WALL AND FRAME OF
SKYLIGHT. INSTALL ALONG
ENTIRE LENGTH OF SKYLIGHT.
BATT INSULATION (R-19)
ALONG ENTIRE LENGTH OF
SKYLIGHT.
REPAIR ANY DAMAGE TO WALL
DUE TO CONSTRUCTION. IF WALL
REQUIRES REPAINTING DUE TO
CONSTRUCTION REPAINT ENTIRE
FACE. TYP.
EXISTING SKYLIGHT FRAME.
SPRAY FOAM INSULATION;
DO NOT ALLOW TO DRIP
DOWN WALL OR STAIN
WALL FINISH.
ANODIZED TRIM TO MATCH
EXISTING SKYLIGHT FRAME FINISH.
SEALANT ENTIRE PERM.
EACH SIDE OF TRIM.
AIR BARRIER MEMBRANE
(SHOWN DASHED)
EXTERIOR
INTERIOR
REMOVE EXISTING
SEALANT. REPLACE W/
SEALANT & BACKER ROD.
*NOTE DO NOT APPLY
SEALANT ABOVE STEEL LINTEL.
DETAIL APPLIES TO
THIS CONDITION AT
ALL LOCATIONS
AROUND PERIMETER
OF BUILDING.
CLEAN RUST FROM EXISTING
STEEL LINTEL AND FLASHING.
REPAINT WITH 099113-1
REMOVE AND
SALVAGE EXISTING
TRIM. REINSTALL
AFTER COMPLETION
OF WORK BEHIND.
SEALANT PERM.
ALL SIDES
AIR BARRIER MEMBRANE
NOT TO BE EXPOSED
AFTER REINSTALLATION
OF TRIM
REMOVE EXISTING
SEALANT & BACKER
ROD. REINSTALL
SEALANT & BACKER
ROD W.O.
EXTERIOR
INTERIOR
076200-1 (20 GAUGE)
FASTEN TO INTERIOR FACE
OF CMU AND SET IN SEALANT
ON TOP OF CMU.
*REMOVE EXISTING
INSULATION AT THIS
LOCATION, W.O. NOTE THAT
ALL REMOVED INSULATION
SHALL BE REPLACED W/ NEW.
072100-1 (R-19)
061600-1
072713-1 (SHOWN DASHED)
WRAP UP TO DECK AND ON
TO WALL.
EXTERIORINTERIOR
DETAIL OCCURS AT
EXTERIOR WALL OF
ROOMS A107a, A128b, A115, AND A136.
REMOVE EXISTING
SEALANT. REPLACE W/
SEALANT & BACKER ROD.
*NOTE DO NOT APPLY
SEALANT ABOVE STEEL LINTEL.
DETAIL APPLIES TO
THIS CONDITION AT
ALL LOCATIONS
AROUND PERIMETER
OF BUILDING.
CLEAN RUST FROM EXISTING
STEEL LINTEL AND FLASHING.
REPAINT WITH 099113-1
REMOVE EXISTING
CAULK AND SEAL
AROUND ALL
PENETRATIONS.
FIELD VERIFY ALL
PENETRATIONS.HATCH REGION
SAME DETAIL AS
6A301
AIR BARRIER (SHOWN
DASHED IN SECTION) TO
HAVE 4" OVERLAP FROM
EXTERIOR WALL TO SIDE
WALL AND STRUCTURE.
EXISTING INSULATION W.O.
TO BE REMOVED AND
REPLACED ACCORD TO
DETAIL 6A301.
THIS PIECE REMOVED
FROM OPENING TO
SHOW EXISTING GAP
BETWEEN CMU AND
STRUCTURAL BEAM.
CLOSE OPENING W/
FIBERGLASS SHEATHING
ON METAL STUDS
F.V.
F .V
/4
SECURITY ASTRAGAL
FULL HEIGHT OF DOOR.
FIELD VERIFY DOOR
DIMENSIONS.
EXISTING DOOR
EXISTING STRIKE PLATE
NEW ADHESIVE
CONTACT SEAL FULL
HEIGHT OF DOOR.
FIELD VERIFY OPENING
BETWEEN DOORS
INFORM ARCHITECT
PRIOR TO
INSTALLATION IF GAP
IS TOO WIDE TO BE AIR
TIGHT WITH NEW SEAL.
NEW ADHESIVE BULB
SEAL FULL HEIGHT OF
DOOR. ATTACHED TO
SECURITY ASTRAGAL.
F .V
SEALANT & BACKER ROD SHALL
BE NEAT AND UNIFORM BETWEEN
GLAZING UNITS. CLEAN ANY
EXCESS SEALANT FROM
SURROUNDING SURFACES.
SEALANT BETWEEN GLAZING
AND FRAME
EXISTING
VERTICAL
FRAME
EXISTING OPERABLE OR
NONOPERABLE GLAZING AND
FRAME, W.O. REF ELEVATIONS.
EXISTING OPERABLE OR
NONOPERABLE GLAZING
AND FRAME, W.O. REF
ELEVATIONS.
EXTERIOR INTERIOR
F .V
EXTERIOR INTERIOR
SEALANT & BACKER ROD
SHALL BE NEAT AND UNIFORM
BETWEEN GLAZING UNITS. CLEAN
ANY EXCESS SEALANT FROM
SURROUNDING SURFACES.
EXISTING OPERABLE
GLAZING AND FRAME, REF
ELEVATIONS.
F .V
A R
C H
I T
E C
T S
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
W
O T H
S T
S T E
O V E R
L A N
D P
A R
K K
A N
S A S
P
.6
.5 w w w .h tk a rc h it e c ts
.c o m
S
K A
N S A
S A
V E
S U
IT
E
T O
P E K
A
K A
N S
A S
P
.2
.5
/1
/2
:3 :1
P
M C
U se rs
\z js
\D o c um e nt s\ B ld g
E ne rg y R e p a ir v za c hs ne th e n1
.r vt
A301
B U
IL
D
IN
G
R
E P
A
IR
M E D
IC
A
L A
N D
C O
M M
U N
IC
A
T
IO
N S
H T K
A rc h it e c ts
DETAILS
05/01/2020
GUQE162200
FO
R B
E S
F
IE
L D
T O
P E K
A K
S
ORIGINAL CONTRACT DOCUMENTS
1 1/2" = 1'-0"1
GABLED SKYLIGHT DETAIL 1
3" = 1'-0"2
GABLED SKYLIGHT DETAIL 2
1 1/2" = 1'-0"3
WINDOW HEAD @ WINDOW OPENINGS
3" = 1'-0"5
STOREFRONT JAMB
1 1/2" = 1'-0"6
ENTRY SOFFIT DETAIL
1 1/2" = 1'-0"4
WINDOW HEAD @ SPANDREL
1/4" = 1'-0"8
PIPE AND ELEC. PENETRATIONS
1 1/2" = 1'-0"7
ENTRY SOFFIT 2
12" = 1'-0"9
SECURITY ASTRAGAL
3" = 1'-0"10
OPERABLE WINDOW SEALANT VERTICAL JOINT
3" = 1'-0"11
OPERABLE WINDOW SEALANT HEAD AND SILL
ELECTRICAL SYMBOLS LEGEND
MECHANICAL SYMBOLS LEGEND
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
ME001
GENERAL MECHANICAL AND
ELECTRICAL NOTES
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L
A t a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
M
E d w g
A
M
1 NO SCALE
HWS CONTROL DIAGRAM 2 NO SCALE
BOILER PLANT CONTROL DIAGRAM
3 NO SCALE
CWS CONTROL DIAGRAM
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
ME101
TEMPERATURE CONTROLS
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
M
E d w g
A
M
3 NO SCALE
EXHAUST FAN CONTROL DIAGRAM
1 NO SCALE
VARIABLE AIR VOLUME EXISTING UNIT CONTROL - "AHU-1, 2, & 3"
TYPICAL OF (3) UNITS - (2) INDOORS AND (1) OUTDOORS
CONTROL VALVE SCHEDULE FOR AHU
AND RAF - 1, 2, 3, 4, 5, 6, 7, 8
2 NO SCALE
STATIC PRESSURE 4 NO SCALE
CABINET UNIT HEATER CONTROL
5 NO SCALE
VAV BOX WITH HOT WATER HEAT CONTROL 6 NO SCALE
HVAC EMERGENCY SHUT-OFF SYSTEM
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
ME102
TEMPERATURE CONTROLS
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
M
E d w g
A
M
SIDE ELEVATION
4 NO SCALE
AIR HANDLING UNIT DETAIL
(EXISTING UNIT)
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
1 HVAC DEMOLITION1/4"=1'-0"
PARTIAL FLOOR PLAN
NORTH
NO SCALE
KEY PLAN
NORTH
2 HVAC DEMOLITION1/4"=1'-0"
PARTIAL FLOOR PLAN
NORTH
3 HVAC DEMOLITION1/4"=1'-0"
PARTIAL FLOOR PLAN
NORTH
ME103
PARTIAL FLOOR PLANS - HVAC
DEMOLITION
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
M
E d w g
A
M
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
1 MECH/ELEC DEMOLITION1/8"=1'-0"
PARTIAL FLOOR PLAN
NORTH
ME104
PARTIAL FLOOR PLAN -
MECHANICAL/ELECTRICAL
DEMOLITION
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
M
E d w g
A
M
PLUMBING FIXTURE SCHEDULE
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
P101
PARTIAL FLOOR PLAN -
PLUMBING
1 PLUMBING1/4"=1'-0"
PARTIAL FLOOR PLAN
NORTH
NO SCALE
KEY PLAN
NORTH
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
P d w g
A
M
NORTH
1 HVAC1/8"=1'-0"
FLOOR PLAN SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
M101
FLOOR PLAN - HVAC
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
M d w g
A
M
1 1/8"=1'-0"
FLOOR PLAN
HVAC PIPING
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
M102
FLOOR PLAN - HVAC PIPING
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
M d w g
A
M
2 (VARI-PRIME SYSTEM)NO SCALE
CHILLED WATER SYSTEM PIPING SCHEMATIC
HW LOOP RESET SCHEDULE
1 (VARI-PRIME SYSTEM)NO SCALE
HOT WATER SYSTEM PIPING SCHEMATIC
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
M201
MECHANICAL SCHEMATICS
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
M d w g
A
M
6 NO SCALE
DP SENSOR DETAIL
4 NO SCALE
(3-WAY CONTROL VALVE) 5 NO SCALE
(3-WAY CONTROL VALVE)
(CWP-1)
(HWP-1, HWP-2)
1 NO SCALE
BASE MOUNTED PUMP DETAIL
7 NO SCALE
PUMP PRESSURE GAUGE INSTALLATION DETAIL
2 NO SCALE
(2-WAY CONTROL VALVE)
3 NO SCALE
(2-WAY CONTROL VALVE)
(REFER TO SPECIFICATIONS FOR
VALVE PACKAGE REQUIREMENTS
AT VAV BOXES)
SINGLE WATER COIL DETAIL V.A.V BOX PIPING DETAIL
SINGLE WATER COIL DETAIL
V.A.V BOX PIPING DETAIL
(REFER TO SPECIFICATIONS FOR
VALVE PACKAGE REQUIREMENTS
AT VAV BOXES)
(REFER TO SPECIFICATIONS FOR
VALVE PACKAGE REQUIREMENTS)
(REFER TO SPECIFICATIONS FOR
VALVE PACKAGE REQUIREMENTS)
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
M202
MECHANICAL DETAILS
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
M d w g
A
M
PUMP SCHEDULE
VARIABLE FREQUENCY DRIVE SCHEDULE
PRESSURE INDEPENDENT CONTROL VALVE SCHEDULE
EXISTING AIR HANDLING UNIT SCHEDULE
EXHAUST FAN SCHEDULE
GAS FIRED HOT WATER HEATING BOILER SCHEDULE
EXISTING UNIT HEATER SCHEDULE
EXISTING VAV TERMINAL UNIT SCHEDULE
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
M203
MECHANICAL SCHEDULES
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
M d w g
A
M
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
MP101
PARTIAL FLOOR PLANS - HVAC
1 HVAC1/4"=1'-0"
PARTIAL FLOOR PLAN
NORTH
NO SCALE
KEY PLAN
NORTH
2 HVAC1/4"=1'-0"
PARTIAL FLOOR PLAN
NORTH
3 HVAC1/4"=1'-0"
PARTIAL FLOOR PLAN
NORTH
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
M
P d w g
A
M
PIPING INSULATION SCHEDULE
PIPING MATERIAL SCHEDULE
AIR SEPARATOR SCHEDULE
1 NO SCALE
AIR SEPARATOR/ELIMINATOR DETAIL
CHECK VALVE SCHEDULE
STOP VALVE SCHEDULE
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
MP201
MECHANICAL/ELECTRICAL DETAILS
AND SCHEDULES
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
M
P d w g
A
M
EXTERIOR
MECH.
YARD
MECH./ELEC.
A127 COMM. STOR.
A126
VIDEO/PORTRAIT
STUDIO
A122
COMM.
MAINTENANCE
A125
OFF.
A123
CORR.
A105
OFF.
A109
VAULT
A108
DOC. DEST.
A112
J.
A124
COMM./TRAINING
RM
A113
VEST
A106
FRAME/TELE.
A114
PRINTING
A111
A110a
STOR.
A110b
INFO. MANAGE.
A110
OFF.
A107d
OFF.
A107c
OFF.
A107b
LOBBY
A102
VEST.
A100
VEST.
A104
CORR.
A156
VEST
A157
CLRM
A134
SUPPORT
A118
OFF.
A118a
OFF.
A119
LAB.
A129a
ADMIN.
A144
STOR.
A141
OFF.
A135
CLRM
A117
EXAM
A154
HEADEND
MAINTENANCE
A121
XRAY
A146
XRAY
A145
OFF
A137
ADMIN.
A140
ADMIN.
A138
DENTAL OPER.
A139
LAB.
A142
MECH.
A155
ADMIN.
A136
WOMEN
A116
MEN
A115
T.
A143
J.
A131
T.
A132
EXAM
A153
EXAM
A152
EXAM
A151
EXAM
A150
EXAM
A148
AUDIO
A149
OFF.
A133
OFF.
A133b
OFF.
A133a
CONF.
A128b
OFF.
A128a
OFF.
A107a
ADMIN.
A128
ENG.
SERVICES/HEALTH
A129
OFF.
A128d
OFF.
A128c
ADMIN.
A130
OPEN OFF.
A107
VIDEO CONTROL
A120
STOR.
A130a
FIRST AID
A147
FS101
FIRE SPRINKLER PLAN
FIRE SPRINKLER PLAN-MAIN LEVEL
FIRE SPRINKLER PLAN-MEZZANINE
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
C:
\U se rs
\C w ae tz ig \L at im er S om m er s a nd A ss oc ia te s\ Al l L
SA
S ta ff
- D oc um en ts
\(M )\2
6\
KA
N
G\ Bu ild in g2
0H
VA
Cu pg ra de sP ha se 2-
6\
CA
D
\F
IR
E
PR
O
TE
CT
IO
N \1
9-
-0 7\
FS
1.
dw g, /1 /2
9:
:5
AM
, 1
:1
1 POWER1/8"=1'-0"
FLOOR PLAN
NORTH
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
E101
FLOOR PLAN - POWER
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
E d w g
A
M
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
E102
PARTIAL FLOOR PLANS - POWER
NORTH
1 POWER1/4"=1'-0"
PARTIAL FLOOR PLAN
2 POWER1/4"=1'-0"
PARTIAL FLOOR PLAN
NORTH
3 POWER1/4"=1'-0"
PARTIAL FLOOR PLAN
NORTH
NO SCALE
KEY PLAN
NORTH
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
E d w g
A
M
2 LIGHTING1/8"=1'-0"
PARTIAL FLOOR PLAN
UPPER ROOMS
A127 & A126
3 NO SCALE
HALLWAY SECTION
LIGHT FIXTURE SCHEDULE
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
1 LIGHTING1/8"=1'-0"
FLOOR PLAN
NORTH
E201
FLOOR PLAN - LIGHTING
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
E d w g
A
M
1 FIRE ALARM1/8"=1'-0"
FLOOR PLAN
NORTH
2 .NO SCALE
ANTENNA MOUNTING DETAIL
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
FA101
FLOOR PLAN - FIRE ALARM
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
F A d w g
A
M
NFPA SYMBOLS LEGEND
3 NO SCALE
INFORMATION SIGN DETAIL
CAUTION
Room protected by ECARO - 25 In Case of Fire Keep Door Closed
FLASHING LIGHT
MEANS ECARO-25
HAS DISCHARGED
Manual
ECARO-25
Discharge
Station
SHEET CONTENTS:
HTK PROJECT NUMBER:
SHEET NUMBER:
DATE:
REVISED DATE:
05/01/2020
H
TK
A rc hi te ct s
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers & Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647
Email: lsapa@lsapa.com
LSA PROJECT NO. 1608026
B U
IL
D
IN
G
R
EP
AI
R M
ED
IC
AL
A
N D
C O
M M
U N
IC
AT
IO
N
S
FO
R
B
ES
F
IE
LD
T
O
PE
K A, K S
GUQE162200
G U
Q E1
ORIGINAL CONTRACT DOCUMENTS
FA102
PARTIAL FIRST FLOOR PLANS -
FIRE SUPPRESSION SYSTEM
NORTH
1 HVAC1/4"=1'-0"
PARTIAL FLOOR PLAN - FRAME/TELE A114 PARTIAL FLOOR PLAN - VAULT A108
NORTH
2 HVAC1/4"=1'-0"
C U s e r s n b o u r n e L a t i m e r
S o m m e r s a n d
A s s o c i a t e s A l l
L a f f
D o c u m e n t s M
K
A N
G B u i l d i n g H
V A
C u p g r a d e s P h a s e C
A D
F A d w g
A
M
| Sheets |
| G101 - TITLE SHEET |
| A101 - FLOOR PLAN |
| A201 - BUILDING ELEVATIONS |
| A301 - DETAILS |
File details come from the government source that posted it. Updated .