Attachment 1 - 663A4-23-203 - HP2A HP2B PHASE II - IFC 231121 Drwgs.pdf
PDF 11 MB Posted
- Attached to
- Y1DA--Construction Project 663A4-24-203 Replace HVAC HP3, Bldg. 19 Federal contract opportunity
- Solicitation number
- 36C26024R0082
About this file
This document appears to be a government solicitation (Solicitation Number: 36C26024R0082) for a construction project to replace HVAC at Building 19 (Y1DA--Construction Project 663A4-24-203 Replace HVAC HP3, Bldg. 19). The solicitation is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The government will use best value tradeoff procedures to evaluate proposals based on technical approach, key personnel qualifications, past performance, and price. Proposals are due on September 10, 2024 at 11:00 AM PST. The government will award a firm-fixed-price construction contract. Site visits are mandatory. The government may conduct price realism analysis.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C26024R0082 0001.docx | DOCX document | |
| Contractor Questions and Answers.pdf | ||
| Attachment 7 - 663A4-23-203 - 663A4-24-203 WD-GD WA20240111 07.12.2024.pdf | ||
| Attachment 6 - 663A4-23-203 - 663A4-24-203 - Limitations on Subcontracting-Construction.pdf | ||
| Attachment 5- 663A4-23-203- 663A4-24-203 - SOW - 240807.pdf | ||
| 36C26024R0082.docx | DOCX document | |
| Attachment 8 - 663A4-23-203 - 663A4-24-203 - Past Performance Questionnaire.docx | DOCX document | |
| Attachment 2 - 663A4-23-203 - HP2A HP2B PHASE II - Specifications.pdf | ||
| Attachment 10 - 663A4-23-203 - 663A4-24-203 - Price Schedule Division Breakout.xlsx | XLSX spreadsheet | |
| Attachment 9 - 663A4-23-203 - 663A4-24-203 - Contractor Rules of Behavior.pdf | ||
| Attachment 4 - 663A4-24-203 - Replace HVAC HP3 - Specifications .pdf | ||
| Attachment 3 - 663A4-24-203 -REPLACE HVAC HP3 - DRAWINGS.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DIMENSION TO FACE OF
FRAMING, FACE OF
CONCRETE, GRID
LINE, OR AS NOTED.
CLEAR DIMENSION TO
FINISH FACE OR AS NOTED
SURFACE SLOPE
NORTH ARROW
PROJECT NORTH
(SEE CIVIL FOR TRUE
NORTH)
DRAWING REVISION NEW SPOT ELEV
WINDOW TYPE -
REF WINDOW SCH
DOOR TAG
WINDOW TAG
CALLOUT
DRAWING NUMBER
DRAWING NUMBER
EXTERIOR ELEVATION
DOOR NUMBER -
REF DOOR SCH
SHEET NUMBER
EXISTING SPOT ELEV
ELEVATION TAG
KEYNOTE
BUILDING SECTION
WALL SECTION
SHEET NUMBER
ROOM TAG
(E) 98.75'
INTERIOR ELEVATION
0' - 1 1/4"
0' - 1 1/4"
A101
SIM
A101
SIM
DRAWING NUMBER
SHEET NUMBER
98.75'
ROOM NUMBER
1/4:12
SLOPE
Room name
150 SF
SYMBOLS AND FILL PATTERNS
EARTH
GRAVEL
ASPHALT
METAL - STEEL
MASONRY - CONCRETE BLOCK
WOOD - FINISH
*WOOD - CONTINUOUS
INSULATION - BATT
INSULATION - RIGID
INSULATION - ACOUSTICAL
WOOD - PLYWOOD
GYPSUM BOARD
GLASS
WOOD - PARTICLE BOARD
METAL - ALUMINUM
CONCRETE
MASONRY - BRICK
SAND
*WOOD - BLOCKING
INSULATION - SEMI
RIGID
1t
A101
SIM
A3.00
A3.00
FINISH TAG
A11
AC
GROUP
ASSEMBLY
STUD SIZE
MODIFIER
WALL TAG
Name Elevation
CEILING HEIGHT ABOVE
FINISHED FLOOR- ALL
CEILINGS 9'-0" UNLESS
OTHERWISE NOTED.
CEILING MATERIAL
CEILING TAG
1t 9'-0"
A-1
PROJECT CONTACTS
VA PUGET SOUND HEALTH CARE SYSTEM
AMERICAN LAKE DIVISION
9600 VETERANS DRIVE, TACOMA, WA 98493
Owner:
Architect:
Mechanical/ Electrical Engineers
GENERAL NOTES
CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO PROCEEDING WITH
THE WORK.
DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS. DO NOT SCALE DRAWINGS. NOTIFY THE ARCHITECT
OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK.
CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS.
CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND COORDINATION OF SUBCONTRACTOR'S WORK, COMPLIANCE WITH THE DRAWINGS AND SPECIFICATIONS, ACCURATE LOCATION OF STRUCTURAL
MEMBERS, AND OPENINGS FOR MECHANICAL, ELECTRICAL, AND MISCELLANEOUS EQUIPMENT.
CONTRACTOR SHALL VERIFY DIMENSIONS AND CLEARANCES FROM MANUFACTURER PRIOR TO THE
CONSTRUCTION AND INSTALLATION OF ALL EQUIPMENT, FURNISHINGS, AND ACCESSORIES.
CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE DURING CONSTRUCTION
AND UNTIL PROJECT COMPLETION.
CONTRACTOR SHALL LOCATE AND PROTECT EXISTING UTILITIES, WHETHER INDICATED IN DRAWINGS OR
NOT.
SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL AND EQUIPMENT
INFORMATION.
1.
2.
3.
4.
5.
6.
7.
8.
x x x x x x x x x x x x x xx x xx x x x x x x x x x x x x x x x x xx x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
N
VAMC AMERICAN LAKE
MAIN PARKING
1662 16
M U S S E R
C T.
VETERANS DR.
T3
T5 T100
92 C
HA
SE
L N.
MU
SS
ER
A
VE
3E N G
LE
W A Y
8 141
CHASE DR.
T98
E N G
LE
W A Y
E N G
LE
C T.
T97
T92
T2
T1
VETERANS DR.
x x x x x x x x x x x x x x x x x x x x x x x x x x x x
AMERICAN LAKE
TACOMA, WASHINGTON
PIERCE COUNTY
PROJECT SITE
BUILDING 19
--- NONE
& AND
@ AT
± APPROXIMATELY
CENTERLINE
Ø DIAMETER
# NUMBER
" INCH(ES)
' FOOT (FEET)
ANGLE
PERPENDICULAR
PLATE OR PROPERTY LINE
A
ACOUS ACOUSTICAL
A.D. AREA DRAIN
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
AGGR AGGREGATE
AL ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASB ASBETOS
ASPH ASPHALT
B
BD BOARD
BITUM BITUMINOUS
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BR BUMPER RAIL
C
CAB CABINET
C.B. CATCH BASIN
CER CERAMIC
C.I. CAST IRON
CG CORNER GUARD
CGF CORNER GUARD FULL HEIGHT
CHR CHAIR RAIL
CLG CEILING
CLKG CAULKING
CLO CLOSET
CLR CLEAR
C.O. CASED OPENING
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUOUS
CORR CORRIDOR
CTSK COUNTERSUNK
CNTR COUNTER
D
DBL DOUBLE
DEPT DEPARTMENT
D.F. DRINKING FOUNTAIN
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DISP DISPENSER
DN DOWN
D.O. DOOR OPENING
DR DOOR
DWR DRAWER
DS DOWNSPOUT
D.S.P. DRY STANDPIPE
DWG DRAWING
E
E EAST
(E) EXISTING
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
EP ELECTRICAL PANEL
ABBREVIATIONS
EQ EQUAL
EQUT EQUIPMENT
EWC ELECTRIC WATER COOLER
EXST EXISTING
EXPO EXPOSED
EXT EXTERIOR
F.A. FIRE ALARM
F.B. FLAT BAR
F.D. FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FHC FIRE HOSE CABINET
FIN FINISH
FL FLOOR
FLOUR FLOURESCENT
F.O.C. FACE OF CONCRETE
F.O.F. FACE OF FINISH
F.O.S. FACE OF STUDS
FPRF FIREPROOF
FT FOOT OR FEET
FTG FOOTING
FURR FURRING
FUT FUTURE
G
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GL GLASS
GND GROUND
GR GRADE
GYP GYPSUM
H
H.B. HOSE BIB
HC HOLLOW CORE
HDWD HARDWOOD
HDWE HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HR-E HANDRAIL, EXISTING
HR-ME HANDRAIL, MATCH EXISTING
HR-1 HANDRAIL, NEW
HGT HEIGHT
I
I.D. INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
J
JAN JANITOR
JT JOINT
K
KIT KITCHEN
L
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LT LIGHT
M
MAX MAXIMUM
M.C. MEDICINE CABINET
MECH MECHANICAL
MEMB MEMBRANE
MET METAL
MFR MANUFACTURER
M.H. MANHOLE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
M.O. MASONRY OPENING
MTD MOUNTED
MUL MULLION
N
N NORTH
(N) NEW
N.I.C. NOT IN CONTRACT
NO. NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
O.A. OVERALL
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI OWNER FURNISHED, OWNER INSTALLED
OFF OFFICE
OPNG OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
Q
Q.T. QUARRY TILE
R
R RISER
(R) RELOCATE
RAD RADIUS
RD ROOF DRAIN
REF REFERENCE
REFR REFRIGERATOR
RGTR REGISTER
REQ REQUIRED
RESIL RESILIENT
RM ROOM
R.O. ROUGH OPENING
R.W.L. RAIN WATER LEADER
S
S SOUTH
SC SOLID CORE
S.C.D SEAT COVER DISPENSOR
SCHED SCHEDULE
S.D. SOAP DISPENSER
SECT SECTION
SH SHELF
SHC SHOWER CURTAIN
SHR SHOWER
SHT SHEET
SIM SIMILAR
S.N.D. SANITARY NAPKIN DISPENSER
S.N.R. SANITARY NAPKIN RECEPTACLE
S.P.T. SPECIMIN PASS THROUGH
SQ SQUARE
S.T STAINLESS STEEL
S.SK SERVICE SINK
STA STATION
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SUSP SUSPENDED
SYM SYMMETRICAL
T
T TREAD
T.B. TOWEL BAR
T.C. TOP OF CURB
TEL TELEPHONE
T&G TONGUE AND GROOVE
THK THICK
T.P. TOP OF PAVEMENT
T.P.D. TOILET PAPER DISPENSER
TV TELEVISION
T.W. TOP OF WALL
TYP TYPICAL
U
UL UNDERWRITERS LABORATORY
UNF UNFINISHED
UR URINAL
V
VERT VERTICAL
VEST VESTIBULE
W
W WEST
W/ WITH
W.C. WATER CLOSET
WD WOOD
W/O WITHOUT
WP WATERPROOF
WPR WALL PROTECTION
WSCT WAINSCOT
WT WEIGHT
CL
PL
C
LA
R K
KJ
O
S
AR
C H
IT
EC
TS
, L
LC
C O
PY
R
IG
H
T
8 911 2 3 4 5 6 7
A
BB
C D
E
FF
E D
C B
76543211 9800
A th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e in c h o n e in c h o n e in c h o n e in c h o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
U.S. GOVERNMENT PRINTING OFFICE:1984-440-467
DateDate
Solicitation Number
Project No.
DRAWING NO.
Project Title
Drawn: Building Number
Location
DateName Initials
Safety Office
DIR. FACMGT.
COO
CEO
Submittal
Construction
For:
Approved
Approved: Medical Center Director
CADD Information:
Date o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
RevisionsRevisions
VA FORM 08-6231A,JAN 1990
Checked:
6/ 3/
:1
4:
A M
BUILDING 19 - REPLACE HVAC - PHASE II
AMERICAN LAKE DIVISION
VA PUGET SOUND HEALTH CARE SYSTEM
PROJECT NO. 663A4-23-203
SOLICITATION NO.
TACOMA, WASHINGTON 98493
VETERANS DRIVE
1/32" = 1'-0"1 VICINITY MAP
U.S. Department of Veterans Affairs
Sheet List Table Sheet Number Sheet Title
G0.00 GENERAL NOTES, SYMBOLS, SHEET INDEX
A1.00 EXISTING FLOOR PLAN
A2.01 WALL AND PARTITION TYPES
A2.02 ROOM FINISH PLAN
A3.00 REFLECTED CEILING PLAN
A4.00 DETAILS
A8.01 WINDOW DETAILS
ES0.0 ELECTRICAL LEGEND
ED1.0 PARTIAL FLOOR PLAN - DEMOLITION
ES2.0 PARTIAL FLOOR PLAN - POWER
ES4.0 PANEL SCHEDULES & DISCONNECT DETAIL
MH0.0 MECH LEGENDS
MH0.1 HVAC SCHEDULES
MD1.0 PARTIAL FLOOR PLAN - DEMO
MH2.1 PARTIAL FLOOR PLAN - HVAC & PIPING
MH2.2 SEQUENCE OF OPERATIONS & POINTS LIST
MH3.0 EXISTING ROOF PLAN - HVAC
MH4.0 ZONING PLAN - HVAC
MH5.0 HVAC DETAILS
AMERICAN LAKE CAMPUS
GENERAL NOTES, SYMBOLS,
ABBREVIATIONS & SHEET INDEX
REPLACE HVAC BLDG 19 - PHASE II 100%
NCK
BB
9/22/22
663A4-23-203
G0.00Approved: Chief Engineer
WAQAS
LOADING
DOCK
OFFICE OFFICEOFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
OPEN OFFICE
OFFICE OFFICE
RECORDS
OPEN OFFICE
OPEN OFFICE
BOILER ROOM
MEN
WOMEN
WAITING
WORK STNS.
STORAGE
IT/TEL
CALL CENTER
CORRIDOR
CORRIDOR
TOILET
CONFERENCE
CORRIDOR
HAC
BOILER ROOM
611 S.F.
1-HP2A EXISTING
1-HP2B EXISTING
EXISTING CONCRETE
PAD
C
LA
R K
KJ
O
S
AR
C H
IT
EC
TS
PY
R
IG
H
T
8 911 2 3 4 5 6 7
A
BB
C D
E
FF
E D
C B
76543211 9800
A th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e in c h o n e in c h o n e in c h o n e in c h o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
U.S. GOVERNMENT PRINTING OFFICE:1984-440-467
DateDate
Solicitation Number
Project No.
DRAWING NO.
Project Title
Drawn: Building Number
Location
DateName Initials
Safety Office
DIR. FACMGT.
COO
CEO
Submittal
Construction
For:
Approved
Approved: Medical Center Director
CADD Information:
Date o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
RevisionsRevisions
VA FORM 08-6231A,JAN 1990
Checked:
AMERICAN LAKE CAMPUS
EXISTING FLOOR PLAN REPLACE HVAC BLDG 19 - PHASE II
NCK
BB
9/22/22
663A4-24-203
A1.00Approved: Chief Engineer
WAQAS
AutoCAD SHX Text
CANOPY ABOVE
AutoCAD SHX Text
CANOPY ABOVE
AutoCAD SHX Text F.E.
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text 1A20
AutoCAD SHX Text 87 S.F.
AutoCAD SHX Text 89 S.F.
AutoCAD SHX Text 100 S.F.
AutoCAD SHX Text 1A18
AutoCAD SHX Text 86 S.F.
AutoCAD SHX Text 88 S.F.
AutoCAD SHX Text 1A16A
AutoCAD SHX Text 1A16
AutoCAD SHX Text 1A14
AutoCAD SHX Text 93 S.F.
AutoCAD SHX Text 1A12A
AutoCAD SHX Text 88 S.F.
AutoCAD SHX Text 1A12
AutoCAD SHX Text 97 S.F.
AutoCAD SHX Text 1A10
AutoCAD SHX Text 1286 S.F.
AutoCAD SHX Text 1A11
AutoCAD SHX Text 153 S.F.
AutoCAD SHX Text 1A17
AutoCAD SHX Text 99 S.F.
AutoCAD SHX Text 1A15
AutoCAD SHX Text
MAIN POWER DISC.
AutoCAD SHX Text
MPD
AutoCAD SHX Text
EP
AutoCAD SHX Text
EP
AutoCAD SHX Text 19A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MAIN POWER DISCONNECT
AutoCAD SHX Text
MPD
AutoCAD SHX Text
SAFETY BOLLARD
AutoCAD SHX Text F.E.C.
AutoCAD SHX Text
SAFETY BOLLARD
AutoCAD SHX Text 434 S.F.
AutoCAD SHX Text 1A42
AutoCAD SHX Text 1A34
AutoCAD SHX Text 1698 S.F.
AutoCAD SHX Text
LOW.V
AutoCAD SHX Text
LOW.V
AutoCAD SHX Text
O.H. DOOR
AutoCAD SHX Text 1A03
AutoCAD SHX Text 505 S.F.
AutoCAD SHX Text 1A03A
AutoCAD SHX Text 153 S.F.
AutoCAD SHX Text F.E.C.
AutoCAD SHX Text
(TWO LEVEL SPACE BELOW GRADE)
AutoCAD SHX Text
UP
AutoCAD SHX Text 614 S.F.
AutoCAD SHX Text
OVER-HEAD DOOR
AutoCAD SHX Text 52 S.F.
AutoCAD SHX Text 1A01A
AutoCAD SHX Text 79 S.F.
AutoCAD SHX Text 1A01B
AutoCAD SHX Text 181 S.F.
AutoCAD SHX Text 1A02
AutoCAD SHX Text 95 S.F.
AutoCAD SHX Text 1A04
AutoCAD SHX Text 363 S.F.
AutoCAD SHX Text
AutoCAD SHX Text
MANHOLE SEWER ACC.
AutoCAD SHX Text
MANHOLE SEWER ACC.
AutoCAD SHX Text
SPRK RISERS
AutoCAD SHX Text
FD
AutoCAD SHX Text
PIT
AutoCAD SHX Text 1B06
AutoCAD SHX Text 114 S.F.
AutoCAD SHX Text 1B01
AutoCAD SHX Text 603 S.F.
AutoCAD SHX Text 1B02
AutoCAD SHX Text 90 S.F.
AutoCAD SHX Text 1B03
AutoCAD SHX Text 123 S.F.
AutoCAD SHX Text 1B04
AutoCAD SHX Text 70 S.F.
AutoCAD SHX Text 1A21
AutoCAD SHX Text 243 S.F.
AutoCAD SHX Text 1B04
AutoCAD SHX Text 223 S.F.
AutoCAD SHX Text 1A22
AutoCAD SHX Text 67 S.F.
AutoCAD SHX Text 1B05
AutoCAD SHX Text 223 S.F.
AutoCAD SHX Text
FD
AutoCAD SHX Text F.E.C.
AutoCAD SHX Text
SPACE SAVER
AutoCAD SHX Text
MOBIL SHELVING
AutoCAD SHX Text
SPACE SAVER
AutoCAD SHX Text
MOBIL SHELVING
AutoCAD SHX Text
MATCHLINE
AutoCAD SHX Text
BUILDING 0020
AutoCAD SHX Text
MATCHLINE
AutoCAD SHX Text
BUILDING 0020
AutoCAD SHX Text
MECH EQUIP
AutoCAD SHX Text F.E.C.
AutoCAD SHX Text
FD
AutoCAD SHX Text
DOCK LEVELER
AutoCAD SHX Text
DN
AutoCAD SHX Text
(TWO LEVEL SPACE BELOW GRADE)
AutoCAD SHX Text
MANHOLE
AutoCAD SHX Text
SEWER
AutoCAD SHX Text
ACC.
AutoCAD SHX Text
SPRK RISERS
AutoCAD SHX Text
FD
AutoCAD SHX Text
PIT
AutoCAD SHX Text
FD
A = ACOUSTIC WALL (STC RATING)
F = FURRING WALL
H = SHAFT WALL, RATED (I.B.C. NUMBER)
P = PARTIAL HEIGHT, NON-RATED
R = RATED FIRE BARRIER (I.B.C. NUMBER)
S = SMOKE PARTITION (I.B.C. NUMBER)
0 = NON-RATED, FRAMING FULL HEIGHT,
FINISH FULL ONE SIDE, SEALANT
1 = 1-HOUR RATED, FIRE TAPE AND CAULK
2 = 2-HOUR RATED, FIRE TAPE AND CAULK
3 = 3-HOUR RATED, FIRE TAPE AND CAULK
4 = 45 STC RATING, INSULATION AND SEALANT
5 = 56 STC RATING, RESILIENT CHANNELS,
INSULATION AND SEALANT
6 = 63 STC RATING, RESILIENT CHANNELS,
INSULATION AND SEALANT
7 = FRAMING 6" ABOVE CEILING, FINISH 6"
ABOVE CEILING
8 = FRAMING FULL HEIGHT, FINISH 6"
ABOVE CEILING
1 = 5/8" METAL FURRING CHANNELS
OVER EXISTING SUBSTRATE
2 = 2 1/2" METAL STUDS AT 16"O.C.
3 = 3 1/2" WOOD STUDS AT 16"O.C.
4 = 3 5/8" METAL STUDS AT 16"O.C.
5 = 5 1/2" WOOD STUDS AT 16"O.C.
6 = 6" METAL STUDS AT 16"O.C.
7 = 7 1/4" WOOD STUDS AT 16"O.C.
8 = 8" METAL STUDS AT 16"O.C.
9 = DOUBLE PLUMBING WALL, DIM.
OUT-OUT, 3 5/8" STUDS AT 16"O.C.
A = ACOUSTIC INSULATION & SEALANT
C = 5/8" RESILIENT FURRINGCHANNELS
E = EXISTING CONSTRUCTION
L = LEAD LINED GYPSUM BOARD PER
PHYSICIST REPORT
P = PLYWOOD UNDERLAYMENT, SHEAR
OR WALL REINFORCEMENT
T = TILE FINISH AREA: SUBSTITUTE
CEMENTITIOUS BACKER BOARD
S= SHEAR WALL
GROUP
ASSEMBLY
STUD SIZE
MODIFIER
WALL TYPE LEGEND
A11-AC
GROUP
ASSEMBLY
STUD SIZE
MODIFIER(S)
WALL TAG
IN-WALL TAG
GROUP
ASSEMBLY
STUD SIZE
WHERE PARTITIONS ARE U.L. LISTED
ASSEMBLIES FOR PROPRIETARY
MANUFACTURERS, PROVIDE U.L. LISTED
ASSEMBLIES FOR ANY ALTERNATE
PRODUCTS INSTALLED.
GENERAL NOTE
A11-AC
MODIFIER(S)
01 1000.A0
SPEC SECTION
NOTE NUMBER
KEYNOTE
A11 A
T
C
P
SECTION
PLAN
6"
X = 3 1/8"
X = 4 1/4"
X = 6 5/8"
X
EXISTING WALL
FACE OF EXISTING WALL
F72
F74
F76
CEILING- SEE ROOM FINISH
SCHEDULE AND RCP FOR HEIGHT
AND FINISH
METAL STUD FRAMING
STRUCTURE
BASE AS SCHEDULE
1 LAYER 5/8" GYPSUM
BOARD
PROVIDE R-19 INSULATION AT
EXTERIOR WALLS ONLY
SECTION
PLAN
X = 3 3/4"
X = 4 7/8"
X = 7 1/4"
X
6"
P74
P76
P72
CEILING- SEE ROOM FINISH
SCHEDULE AND RCP FOR HEIGHT
AND FINISH
METAL STUD FRAMING
45 DEGREE METAL STUD BRACING
TO STRUCTURE AT 4'-0"O.C. AS
REQUIRED
BASE AS SCHEDULE
1 LAYER 5/8" GYPSUM
BOARD EACH SIDE
SECTION
PLAN
X = 1 1/4"F71
X 6"
EXISTING WALL
FACE OF EXISTING WALL
5/8" HAT CHANNEL
CEILING- SEE ROOM FINISH
SCHEDULE AND RCP FOR HEIGHT
AND FINISH
STRUCTURE
BASE AS SCHEDULE
1 LAYER 5/8" GYPSUM
BOARD EACH SIDE
5/8" HAT CHANNEL
SECTION
PLAN
X = 4 7/8"
X
R14
METAL STUD FRAMING
FIRE SEALANT07 9200.A5
CEILING- SEE ROOM FINISH SCHEDULE
AND RCP FOR HEIGHT AND FINISH
BASE- SEE ROOM FINISH SCHEDULE
1 LAYER 5/8" GYPSUM
BOARD ON EACH SIDE09 2900.D3
FIRE SEALANT07 9200.A5
STRUCTURE
NEW OR EXISTING
PARTITION
NEW OR EXISTING
PARTITION
SECURE CONT.
RETAINER
W/ #8 x 1" SCREWS
@ 8"O.C. MAX
VINYL ACRYLIC
CORNER GUARD
0'
3"
0' - 3"
WRAP AROUND TYPE
CORNER TYPE
0'
2"
0' - 2"
0'
2"
0' - 2"
VERIFY WITH
PLAN SECTION
CABINET MFGR.
VE
R
IF
Y
W
IT
H C
AB
IN
ET
M
FG
R
0' - 10"
GYPSUM WALL
BOARD,
WRAP BACK SIDE OF
CABINET
TO CENTER
OF HANDLE
5'-0" A.F.F
.6 -1
/4
R .O
FIRE EXTINGUISHER
AND CABINET
2' -0
/2
" R .O
3'
-2 " A
FF
CL
1' - 4 1/2"
5/8" GWB OVER
1-5/8" METAL STUDS
EXISTING
STRUCTURAL COLUMN
1'
1/
2"
CORNER GUARD,
TYP. SEE DETAIL
2/ A2.40
BASE BELOW, TYP
CL
VERIFY MIN. CLR.
REQUIREMENTS-
SEE PLAN
0'
3"
0' - 3"
C
LA
R K
KJ
O
S
AR
C H
IT
EC
TS
PY
R
IG
H
T
8 911 2 3 4 5 6 7
A
BB
C D
E
FF
E D
C B
76543211 9800
A th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e in c h o n e in c h o n e in c h o n e in c h o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
U.S. GOVERNMENT PRINTING OFFICE:1984-440-467
DateDate
Solicitation Number
Project No.
DRAWING NO.
Project Title
Drawn: Building Number
Location
DateName Initials
Safety Office
DIR. FACMGT.
COO
CEO
Submittal
Construction
For:
Approved
Approved: Medical Center Director
CADD Information:
Date o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
RevisionsRevisions
VA FORM 08-6231A,JAN 1990
Checked:
4/ 8/
:2
2:
A M
1 1/2" = 1'-0"
PARTIAL HEIGHT WALLP1
1 1/2" = 1'-0"
FURRING WALLF1
1 1/2" = 1'-0"
ONE HOUR FIRE RATED WALLR1
3" = 1'-0"2 DETAIL - TYPICAL CORNER GUARD
1 1/2" = 1'-0"3 DETAIL-FIRE EXTINGUISHER - TYPICAL
3" = 1'-0"1 DETAIL - TYPICAL COLUMN FURRING_
AMERICAN LAKE CAMPUS
WALL AND PARTITION TYPES
REFERENCE DETAILS
REPLACE HVAC BLDG 19 - PHASE II
NCK
BB
9/22/22
663A4-24-203
A2.01Approved: Chief Engineer
CP
CPT
CT
AT
EXG
GWB
FF
PT-1
RB
VCT
W
SFC
CARPET (WITHOUT CUSHION - BROADLOOM)
CARPET TILE
CERAMIC TILE (FLOOR, BASE & WALL)
ACOUSTICAL CEILING TILE
EXISTING
GYPSUM WALLBOARD SYSTEMS
FACTORY FINISH
COCOA BUTTER EGGSHELL OR EQUIVALENT
RESILIENT BASE (RUBBER, VINYL)
RESILIENT TILE FLOORING (VINYL COMPOSITION TILE)
WALL COVERING (VINYL COATED FABRIC)
SPECIAL FLOOR COVERING
ROOM FINISH ABBREVIATIONS
3 4 5 6 8 10 11 13
G
F
E
B
9 127
D
CPT-1
CPT-1
CPT-1
CPT-1CPT-1
CPT-1
K L
DN
DN
CPT-1
CPT-1
CPT-1
VCT-1
VCT-1
VCT-1
PAINT FLOOR
IN MAILROOM
SFC-1
WALK-OFF
MAT
RECORDS
1A34
CODERS
1A34
SUPERVISOR
1A03A
PASSAGE
1A00
ROI
1A09
MY HEALTHEVET
1A04
ROI/
RECEPTION
1A01A
VESTIBULE
1A011A11
WORK ROOM
1A15
OFFICE
1A17
HKG
1A22
CONFERENCE
ROOM
1A21
PASSAGE
1A19
OFFICE
1A20
CPT-1
OFFICE
1A18
CPT-1
OFFICE
1A16A
CPT-1
OFFICE
1A16
CPT-1
OFFICE
1A14
CPT-1
OFFICE
1A12A
CPT-1
OFFICE
1A12
CPT-1
OFFICE
1A10
WAITING
1A02
MEN'S TLT
1A01A
WOMEN'S TLT
1A01A
TELECOM-1
001A
MAIL ROOM
1A42
CERAMIC TILE FLOORING-
TYPICAL
LOADING
DOCK
MARBLE THRESHOLD,
TYPICAL
ROOM FINISH SCHEDULE - REFERENCE
ROOM
NO. ROOM NAME
FLOOR WALL CEILING WAINSCOT
COMMENTSFLOOR BASE MAT. NORTH EAST SOUTH WEST MAT. FINISH HT MAT. HT
1A10 EXISTING OFFICE
VCT-1 PT-1 PT-1 PT-1 PT-1 ----- ----
CPT-1 RB GWB PT-1 PT-1 PT-1 PT-1 AT FF 8'-0" ----- ----
CPT-1 RB GWB PT-1 PT-1 PT-1 PT-1 AT FF 8'-0" ----- ----
GWB PT-1 PT-1 PT-1 PT-1 AT FF 8'-0"
GWB PT-1 PT-1 PT-1 PT-1 AT FF 8'-0"
CPT-1 RB GWB PT-1 PT-1 PT-1 PT-1 AT FF 8'-0" ----- ----
CPT-1 RB GWB PT-1 PT-1 PT-1 PT-1 AT FF 8'-0" ----- ----
CPT-1 RB GWB PT-1 PT-1 PT-1 PT-1 AT FF 8'-0" ----- ----
CPT-1 RB GWB PT-1 PT-1 PT-1 PT-1 AT FF 8'-0" ----- ----
RB GWB PT-1 PT-1 PT-1 PT-1 AT FF 8'-0" ----- ----
C
LA
R K
KJ
O
S
AR
C H
IT
EC
TS
PY
R
IG
H
T
8 911 2 3 4 5 6 7
A
BB
C D
E
FF
E D
C B
76543211 9800
A th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e in c h o n e in c h o n e in c h o n e in c h o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
U.S. GOVERNMENT PRINTING OFFICE:1984-440-467
DateDate
Solicitation Number
Project No.
DRAWING NO.
Project Title
Drawn: Building Number
Location
DateName Initials
Safety Office
DIR. FACMGT.
COO
CEO
Submittal
Construction
For:
Approved
Approved: Medical Center Director
CADD Information:
Date o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
RevisionsRevisions
VA FORM 08-6231A,JAN 1990
Checked:
4/ 8/
:2
5:
A M
1/8" = 1'-0"1 LEVEL 1 FINISH PLAN_
AMERICAN LAKE CAMPUS
ROOM FINISH PLAN REPLACE HVAC BLDG 19 - PHASE II
NCK
BB
9/22/22
663A4-24-203
A2.02Approved: Chief Engineer
WAQAS
1A11 EXISTING OPEN OFFICE
1A12 EXISTING OFFICE
1A12A EXISTING OFFICE
1A14 EXISTING OFFICE
1A15 WORK ROOM
1A16 EXISTING OFFICE
1A16A EXISTING OFFICE
1A17 EXISTING OFFICE
1A18 EXISTING OFFICE
1A20 EXISTING OFFICE
1A21 CONFERENCE ROOM
1A22 HOUSEKEEPING CLOSET
CPT-1
CPT-1 RB GWB PT-1 PT-1 PT-1 PT-1 AT FF 8'-0" ----- ----1A19 PASSAGE
CPT-1
VCT-1
CPT-1
CPT-1
VCT-1
RB
RB
RB
RB
RB
RB
GWB
GWB
GWB
GWB
PT-1 PT-1 PT-1 PT-1
PT-1 PT-1 PT-1 PT-1
PT-1 PT-1 PT-1 PT-1 AT
AT
AT
AT
FF
FF
FF
FF
8'-0" 8'-0"
8'-0"
8'-0"
1.
2.
3.
4.
5.
6.
7.
GENERAL NOTES
LEGEND
ALL CEILING HEIGHTS ARE TO BE 8'-0" U.N.O.
ALL CEILING HEIGHTS ARE RELATIVE TO TOP OF SLAB
OR SUBFLOOR, U.N.O.
SEE ELECTRICAL AND MECHANICAL PLANS FOR
LOCATIONS OF FIXTURES AND EQUIPMENT.
FIELD VERIFY EXISTING CEILING LAYOUTS PRIOR TO ANY
WORK.
SUSPENDED GYPSUM BOARD CEILINGS SHALL BE
MODIFIED TO FRAME AROUND CEILING INSTALLED
ITEMS. SEE MECHANICAL AND ELECTRICAL DRAWINGS.
FOR TOP OF WALL DETAILS AND HEIGHT OF GYP BOARD
ON WALLS, SEE PLANS, PARTITION TYPES, AND DETAILS.
RECESSED FIXTURES ARE TO MAINTAIN RATINGS WHERE
LOCATED IN RATED CEILING ASSEMBLIES.
ACT-1: "2x4"
ACT-2: "2x4" W/ "2x2" LOOK
CEILING MATERIAL
CEILING HEIGHT
CEILING TAG
1t 9'-0"
2 x 4 DROP-IN FIXTURE
RECESSED DOWNLIGHT
SUPPLY DIFFUSER
RETURN REGISTER
LINEAR SUPPLY DIFFUSER
WALL MOUNTED LIGHT
FIXTURE
LINEAR - INDUSTRIAL FLUORESCENT
NOTE: SEE MEP DWGS. FOR FIXTURE SCHEDULES
3 4 5 6 8 10 11 13
G
F
E
B
9 127
D
C
A
A8.01
TYPICAL @ ALL EXTERIOR WINDOWS
UNLESS OTHERWISE NOTED
1/2"
4" JOINT
SEISMIC JOINT COVER FOR
SUSPENDED
HANGER WIRE TO
CEILING TEE
AS SCHEDULED
METAL DECK ABOVE
1 1/2"
%%UNOTE:
HANGER WIRES SHALL HANG NOT MORE
THAN 1 IN 6 OUT OF PLUMB UNLESS
COUNTER BRACING WIRES ARE PROVIDED
CROSS RUNNERS
12 GA. HANGER WIRE
"HILTI" CEILING
CLIP OR EQUAL
(13 GA. X 3/4" WIDE)
SELF-TAPPING SCREW
1/4"O x 1 1/2"
CLIP ANGLE BENT TO
ANGLE OF SUPPORT
BRACING
WALL ANGLE
STANDARD
POP RIVET
WALL ANGLE @ FIXED EDGE
45° MAX.
STUD STRUT @ 12' OC EACH WAY &
PROVIDE SPLAY BRACING & METAL
IN ROOMS LARGER THAN 144 SQ FT
WITH 3 TIGHT TURNS IN 11/2" (TYP.)
MAIN RUNNERS
12 GA VERT HANGER
WITHIN 6' OF EACH WALL
WIRE (TYP) 45° MAX.
SPLICE MUST BE MECHANICALLY
ATTACHED (SNAP CONNECTION
IS UNACCEPTABLE)
STRUT COMPRESSION BRACE
HANGER WIRE WITH SOLID
- TAPE & WIRE ATTACH TO
1 5/8"x 25 GA METAL STUD
12 GA VERT HANGER @ 4'-0" OC
CONTACT RUNNER @
STRUCTURE ABOVE
- TYP (4 TIGHT TURNS)
12 GA SPLAY BRACE WIRE
2" MAX FROM SPLAY WIRES
TO CROSS RUNNERS
ACOUSTICAL
CEILING TILE
NOTE:
WALL ANGLE @ FREE EDGE
1.
2.
WALL ANGLE
STANDARD
(SEE NOTE #2)
8" MAX.
8" MAX OR 1/4 OF THE LENGTH OF THE END RUNNER, WHICH EVER IS LESS
NAIL HEAD TOWARDS CENTERLINE OF SPAN OF STRUT.
RUNNER SPLICE
PERMITTED ONLY AT RUNNER
6D RING SHANK NAIL - SEE NOTE #2
SLOTTED ANGLE SPACER W/ HORIZ.
12 GA. HANGER WIRE - SEE NOTE #1
C
LA
R K
KJ
O
S
AR
C H
IT
EC
TS
PY
R
IG
H
T
8 911 2 3 4 5 6 7
A
BB
C D
E
FF
E D
C B
76543211 9800
A th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e in c h o n e in c h o n e in c h o n e in c h o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
U.S. GOVERNMENT PRINTING OFFICE:1984-440-467
DateDate
Solicitation Number
Project No.
DRAWING NO.
Project Title
Drawn: Building Number
Location
DateName Initials
Safety Office
DIR. FACMGT.
COO
CEO
Submittal
Construction
For:
Approved
Approved: Medical Center Director
CADD Information:
Date o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
RevisionsRevisions
VA FORM 08-6231A,JAN 1990
Checked:
4/ 8/
:2
5:
A M
N
1/8" = 1'-0"1 REFLECTED CEILING PLAN
3" = 1'-0"2 TYPICAL SUSPENDED ACOUSTICAL CEILING TILE DETAILS
AMERICAN LAKE CAMPUS
REFLECTED CEILING PLAN REPLACE HVAC BLDG 19 - PHASE II
NCK
BB
9/22/22
663A4-24-203
A3.00Approved: Chief Engineer
EQUIP LAYOUT AND CORE
DRILL EXISTING CONCRETE
EQUIP PAD TO 3" EMBED
INSTALL MECHANICAL EQUIPMENT ANCHORS - 58" DIA HILTI
KWIK BOLT WITH EPOXY ADHESIVE IN ACCORDANCE WITH
MANUFACTURERS INSTALLATION INSTRUCTIONS
C
LA
R K
KJ
O
S
AR
C H
IT
EC
TS
PY
R
IG
H
T
8 911 2 3 4 5 6 7
A
BB
C D
E
FF
E D
C B
76543211 9800
A th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e in c h o n e in c h o n e in c h o n e in c h o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
U.S. GOVERNMENT PRINTING OFFICE:1984-440-467
DateDate
Solicitation Number
Project No.
DRAWING NO.
Project Title
Drawn: Building Number
Location
DateName Initials
Safety Office
DIR. FACMGT.
COO
CEO
Submittal
Construction
For:
Approved
Approved: Medical Center Director
CADD Information:
Date o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
RevisionsRevisions
VA FORM 08-6231A,JAN 1990
Checked:
8/ 2/
:0
8:
P M
1" = 1'-0"2 DETAIL - EXISTING CONCRETE SLAB
AMERICAN LAKE CAMPUS
DETAILS REPLACE HVAC BLDG 19 - PHASE II
NCK
BB
9/22/22
663A4-24-203
A4.00Approved: Chief Engineer
WAQAS
1" = 1'-0"1 WEST ELEVATION
EXISTING HP3 ON CONCRETE PAD - NO WORK
1HP2B1HP2A
MECH EQUIP
LA
R K
KJ
O
S
AR
C H
IT
EC
TS
PY
R
IG
H
T
8 911 2 3 4 5 6 7
A
BB
C D
E
FF
E D
C B
76543211 9800
A th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e in c h o n e in c h o n e in c h o n e in c h o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
U.S. GOVERNMENT PRINTING OFFICE:1984-440-467
DateDate
Solicitation Number
Project No.
DRAWING NO.
Project Title
Drawn: Building Number
Location
DateName Initials
Safety Office
DIR. FACMGT.
COO
CEO
Submittal
Construction
For:
Approved
Approved: Medical Center Director
CADD Information:
Date o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
RevisionsRevisions
VA FORM 08-6231A,JAN 1990
Checked:
8/ 2/
:0
8:
P M
AMERICAN LAKE CAMPUS
WINDOW DETAILS - EXISTING REPLACE HVAC BLDG 19 - PHASE II
NCK
BB
9/22/22
663A4-24-203
A8.01Approved: Chief Engineer
MECHANICAL EQUIPMENT EMERGENCY SHUTDOWN SWITCH
MOTOR-RATED SWITCH - SIZE OL PER MOTOR REQUIREMENTS
WP = WEATHERPROOF
OS = OCCUPANCY SENSOR TYPE
OP = OCCUPANCY/PHOTOELECTRIC TYPE
LV = LOW-VOLTAGE
208Y/120V, 3Ø, 4-WIRE PANELBOARD
LOWER CASE LETTER INDICATES SWITCHING GROUP
WALL SWITCH - SUBSCRIPT INDICATES
EQUIPMENT CABINET - TYPE AS NOTED
SINGLE-POLE WALL SWITCH
2 = 2-POLE
3 = 3-WAY
K = KEYED
METER
MOTOR CONNECTION - SEE SCHEDULE FOR MOTOR DATA
EQUIPMENT CONNECTION
MM
COMBINATION STARTER
3-POLE, NEMA SIZE 1 MINIMUM UNLESS NOTED OTHERWISE
HP RATED, 3-POLE, NEMA SIZE 1 MINIMUM, UNLESS NOTED
BY EQUIPMENT MANUFACTURER OR AS NOTED
3-POLE UNLESS NOTED OTHERWISE
DISCONNECT SWITCH
FUSED DISCONNECT SWITCH
OR AS NOTED
PROTECTION AS REQUIRED BY EQUIPMENT MANUFACTURER
3-POLE UNLESS NOTED OTHERWISE - OVERCURRENT
OTHERWISE - OVERCURRENT PROTECTION AS REQUIRED
M STARTER
4 = 4-WAY
SYMBOL
DIAGRAMPLAN
DESCRIPTIONDESCRIPTION
SYMBOLS LEGEND - POWER
SYMBOL
DIAGRAMPLAN
DESCRIPTIONDESCRIPTION
SYMBOLS LEGEND - WIRING DEVICES
ILLUMINATED EXIT SIGN - SINGLE FACE
OCCUPANCY SENSOR WITH POWER PACK CEILING MOUNTED
BATTERY-POWERED EMERGENCY WALLPACK
ILLUMINATION CONTROL STATION
PHOTOELECTRIC CONTROL
ARROW INDICATES DIRECTION OF EGRESS, UNIVERSAL MOUNT
ILLUMINATED EXIT SIGN - DOUBLE FACE
ARROW INDICATES DIRECTION OF EGRESS, UNIVERSAL MOUNT
SYMBOL
DIAGRAMPLAN
DESCRIPTIONDESCRIPTION
SYMBOLS LEGEND - LIGHTING
GROUND ROD
GROUND CONNECTION
SYMBOL
DIAGRAMPLAN
DESCRIPTION
SYMBOLS LEGEND - GROUNDING
SMOKE DETECTOR
HEAT DETECTOR
FIRE ALARM SYSTEM CONTROL PANEL
FIRE ALARM STROBE
FIRE ALARM SMOKE DETECTOR
FIRE ALARM PULL STATION
FIRE ALARM HORN-STROBE
FIRE ALARM PRESSURE SWITCH
FIRE ALARM FLOW SWITCH
SYMBOL
DIAGRAMPLAN
DESCRIPTIONDESCRIPTION
SYMBOLS LEGEND - FIRE ALARM
DUCT-MOUNTED WITH TUBE
BT - BEAM TRANSMITTER
BR - BEAM RECEIVER
I - IONIZATION
P - PHOTOELECTRIC
FIRE ALARM TAMPER SWITCH
POST INDICATOR VALVE
NUMBER INDICATES CANDELLA RATING
CONDUIT - CONCEALED IN OR UNDER FLOOR
LIGHT LINEWEIGHT INDICATES EXISTING INFORMATION
EXISTING TO BE REMOVED
HEAVY LINEWEIGHT INDICATES NEW WORK
CONDUIT OR CABLE VERTICAL DOWN
CONDUIT STUB - TERMINATE WITH BUSHING OR CAP IF UNDERGROUND
CONDUIT OR CABLE VERTICAL UP
CONDUCTORS - CONNECTED
CONDUCTORS - NOT CONNECTED
JUNCTION BOX
PULLBOX - SIZE AS INDICATED OR AS REQUIRED BY CODE
SYMBOL
DIAGRAMPLAN
DESCRIPTION
SYMBOLS LEGEND - GENERAL
MM XX
M
DUPLEX RECEPTACLE NEMA 5-20R, +18" AFF EXCEPT 10"AFF
FOR FURNITURE LOCATIONS
DUPLEX RECEPTACLE NEMA 5-20R, ISOLATED GROUND, +18" AFF UON
RECEPTACLE NEMA 5-20R, CONNECTED TO EMERGENCY CIRCUIT, +18"
AFF UON
RECEPTACLE NEMA 5-20R MOUNTED ABOVE COUNTER. COORDINATE WITH
CASEWORK SHOP DRAWINGS AND ARCHITECTURAL DRAWINGS.
SPECIAL PURPOSE RECEPTACLE TYPE AS SHOWN ON PLANS
COMBINATION FLUSH MOUNTED FLOOR BOX. REFER TO FLOOR PLANS
FOR DEVICE.
CEILING-MOUNTED DUPLEX RECEPTACLE, NEMA 5-20R
DUPLEX RECEPTACLE NEMA 5-20R WITH GROUND FAULT CIRCUIT
INTERRUPTER, +18" AFF UON
POWER/COMM POLE - FLOOR TO CEILING.
STRIP FLUORESCENT
WALL-MOUNTED FLUORESCENT LUMINAIRE
WALL-MOUNTED LUMINAIRE
DOWNLIGHT OR CEILING-MOUNTED LUMINAIRE
DIRECTIONAL LUMINAIRE
WALL WASH LUMINAIRE
WITH BATTERY BACKUP BALLAST
SHADING INDICATES LUMINAIRE
2x4 FLUORESCENT
1x4 FLUORESCENT
2x2 FLUORESCENT
PC
OS
F
TS
PS
FS
PIV
F
TS
PS
FS
PIV
FCP FCP
PB
PANELBOARD
AMPERES SHORT CIRCUIT AVAILABLE (SYMMETRICAL)
XXX
XXXXXX
SYMBOL
DIAGRAM
DESCRIPTIONDESCRIPTION
SYMBOLS LEGEND - POWER
XX
SYMBOL
DIAGRAMPLAN
DESCRIPTION
SYMBOLS LEGEND - COMMUNICATIONS
COMMUNICATIONS - OUTLET @ 18" AFF EXCEPT 10" AFF FOR FURNITURE
(# = REPRESENTS THE NUMBER OF COMMUNICATION PORTS. (IE 1,2,3))
(W = SINGLE COMMUNICATIONS PORT WALL MOUNTED AT +48" AFF.)
(P = PAYPHONE, WALL MOUNTED AT +48" AFF)
COMMUNICATIONS - PAINTED FIRE RESISTANT 3/4" PLYWOOD BACKBOARD
19" COMMUNICATIONS RACK - FLOOR MOUNTED
19" COMMUNICATIONS RACK - WALL MOUNTED
A-1,3,5
POINT OF CONNECTION (POC) BETWEEN NEW AND
EXISTING CIRCUIT
BREAK LINE
CABLE TRAY
MINIMUM 3/4" CONDUIT CONCEALED IN CEILING SPACE OR IN WALL WITH #12
AWG CONDUCTORS, UNLESS OTHERWISE NOTED ON PLAN. PROVIDE
GROUNDING CONDUCTORS SIZED PER NFPA 70.
HOME RUN FROM SOURCE OF SUPPLY
PANEL DESIGNATION
BRANCH CIRCUIT NUMBERS
XXXXX FEEDER TAG - REFER TO FEEDER SCHEDULE
DRAWING CONSTRUCTION ("FLAG") NOTE
EQUIPMENT IDENTIFIER (XX = ABBREVIATION
Y = EQUIPMENT SCHEDULE NUMBER)
MATCHLINE
REVISION CLOUD (ENCIRCLES DRAWING CHANGES MADE SINCE
THE PREVIOUS RELEASE)
DETAIL REFERENCE
SECTION REFERENCE
ELEVATION REFERENCE
REVISION REFERENCE
NORTH REFERENCE
N
XDN
XX
XX.XX
X
XX.XX
X
XX.XX
X
SYMBOL
PLAN
DESCRIPTIONDESCRIPTION
SYMBOLS LEGEND - GENERAL
SECTION IDENTIFICATION NUMBER
SHEET WHERE SECTION IS DRAWN
ELEVATION IDENTIFICATION NUMBER
SHEET WHERE ELEVATION IS DRAWN
DETAIL IDENTIFICATION NUMBER
SHEET WHERE DETAIL IS DRAWN
FLEXIBLE METAL CONDUIT
X-XX
XXXX
EQUIPMENT IDENTIFIER
LIGHT FIXTURE IDENTIFIER - REFER TO LIGHTING FIXTURE SCHEDULE
UNDER-CABINET FLUORESCENT LUMINAIRE
MOUNT SWITCHES AT 48" AFF. TO CL, UON.
ANY COMBINATION OF SWITCH TYPES CAN BE USED. (IE. 3K = 3-WAY
KEYED SWITCH)
J
GENERAL NOTES:
1. CONFORM WITH NATIONAL ELECTRICAL CODE (NEC).
2. ALL MATERIALS TO BE UL LISTED.
3. SCHEDULE ALL POWER OUTAGES WITH VA.
4. MATERIALS SHALL CONFORM TO THE FOLLOWING:
a. CONDUCTORS TO BE COPPER, THWN INSULATION.
b. INTERIOR RACEWAYS TO BE EMT WITH WITH STEEL FITTINGS.
c. EXTERIOR RACEWAYS TO BE RIGID STEEL.
d. EQUIPMENT CONNECTIONS TO BE LIQUIDTITE STEEL FLEX.
5. PROVIDE CORE DRILLING REQUIRED.
6. SEAL ALL CONDUIT PENETRATIONS. PROVIDE UL LISTED FIRE
RATED SEALS MATCHING FIRE RATING OF WALLS AND FLOORS
INSTALLED BY UL QUALIFIED INSTALLERS.
7. COORDINATE ELECTRICAL WORK WITH WORK OF OTHER TRADES.
ELECTRICAL DRAWINGS SHOW ONLY ELECTRICAL WORK AND
SHALL NOT BE USED FOR WORK OF OTHER TRADES.
8. COMPLETION OF WORK SHALL BE EXECUTED IN ACCORDANCE
WITH THE PROJECT SCHEDULE. SCHEDULE INSTALLATION WITH
GENERAL CONTRACTOR AND OTHER TRADES TO ENSURE
PROJECT MILESTONES ARE MET.
9. PROVIDE PULL BOXES AS REQUIRED BY CODE.
10. SEISMIC SUPPORT AND BRACE ELECTRICAL EQUIPMENT AND
RACEWAYS PER CODE, SPECIFICATIONS 13 05 41,
MANUFACTURES RECOMMENDATIONS AND THE FOLLOWING
CRITERIA:
SEISMIC USE GROUP: I
SEISMIC DESIGN CATEGORY D
COMPONENT IMPORTANCE FACTOR: Ip = 1.5 SPECIAL RESPONSE COEFFICIENTS: Sds = 0.814g, Sd1 =0.441g
ICS
FAN SHUTDOWNF F
DOUBLE DUPLEX RECEPTACLE NEMA 5-20R, +18" AFF
EXCEPT 10" AFF FOR FURNITURE LOCATIONS
CARD READER
ELECTRIC DOOR STRIKE
SYMBOL
DIAGRAMPLAN
DESCRIPTION
SYMBOLS LEGEND - SECURITY
WP INDICATES WEATHERPROOFWP
DOOR CONTACT
REQUEST TO EXIT DEVICE
CR
ES
CR
ES
REX REX
CC
PAGING SPEAKER - DUKANE 5A607 WITH WHITE CEILING BAFFLE OR EQUALS
ABBREVIATIONS
@ AT
A (AMP) AMPERE
AC ABOVE COUNTER, ALTERNATING CURRENT
AFF ABOVE FINISHED FLOOR
AIC AMPERES INTERRUPTING
ALT ALTERNATE
ANN ANNUNCIATOR
ARCH ARCHITECT; ARCHITECTURAL
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AWG AMERICAN WIRE GAUGE
BLDG BUILDING
C CONDUIT
CB CIRCUIT BREAKER
CKT CIRCUIT
CLG CEILING
COL COLUMN
COM COMMUNICATION
CT CURRENT TRANSFORMER
CU COPPER
DISC DISCONNECT
DN DOWN
DWG DRAWING
E EXIST, EAST
EC ELECTRICAL CONTACTOR
EDH ELECTRIC DUCT HEATER
EF EXHAUST FAN
EGC EQUIPMENT GROUND CONDUCTOR
EL ELEVATION
ELEC ELECTRIC(AL)
EM EMERGENCY
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EQUIP/EQP EQUIPMENT
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EXH EXHAUST
EXT EXTERIOR
EXIST EXISTING
FA FIRE ALARM
FAA FIRE ALARM ANNUNCIATOR
FAP FIRE ALARM PANEL
FC FOOTCANDLE
FCU FAN COIL UNIT
FDR FEEDER
FIXT FIXTURE
FLA FULL LOAD AMPS
FSD FIRE/SMOKE DAMPER
GFCI GROUND FAULT CIRCUIT INTERRUPTER
HID HIGH INTENSITY DISCHARGE
HOA HAND OFF AUTOMATIC
HP HORSEPOWER
HT HEIGHT
HZ HERTZ
IEEE INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
IN INCH
JB JUNCTION BOX
KCMIL THOUSAND CIRCULAR MILLS
KVA KILOVOLT AMPERES
KW KILOWATT
KWH KILOWATT HOUR
LBS POUNDS
LF LINEAR FEET (FEET)
LRA LOCKED ROTOR AMPS
LTG LIGHTING
LV LOW VOLTAGE
MAX MAXIMUM
MCA MINIMUM CIRCUIT AMPACITY
MCB MAIN CIRCUIT BREAKER
MECH MECHANICAL
MH METAL HALIDE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUG ONLY
MOCP MAXIMUM OVERCURRENT PROTECTION
MS MAGNETIC STARTER
MTD MOUNTED
MTG MOUNTING
N NORTH; NEUTRAL
N/A NOT APPLICABLE
NC NORMALLY CLOSED
NEC NATIONAL ELECTRIC CODE
NEMA NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION
NESC NATIONAL ELECTRICAL SAFETY CODE
NEUT NEUTRAL
NFPA NATIONAL FIRE PROTECTION AGENCY
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
OC ON CENTER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER INSTALLED
OL OVERLOAD
OS OCCUPANCY SENSOR
P PRIMARY
PA PUBLIC ADDRESS
PC PHOTO CELL
PB PILL BOX
PE PHOTO ELECTRIC
PF POWER FACTOR
PH PHASE
PNL PANEL
POC POINT OF CONNECTION
PWR POWER
QTY QUANTITY
RECPT RECEPTACLE
RLA RUNNING LOAD AMPS
RPM REVOLUTIONS PER MINUTE
S SOUTH
SD SMOKE DETECTOR
SHT SHEET
SPEC SPECIFICATION
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
TC TIME CLOCK
TEL TELEPHONE
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION
TYP TYPICAL
UBC UNIFORM BUILDING CODE
UFC UNIFORM FIRE CODE
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITERS LABORATORIES
UON UNLESS OTHERWISE NOTED
UV UNIT VENTILATOR
V VOLT
W WATT, WEST
W/ WITH
W/O WITHOUT
WH WATER HEATER
WP WEATHERPROOF
X REACTANCE
XFMR TRANSFORMER
Z IMPEDANCE
& AND
IE: THAT IS
# NUMBER
ELECTRICAL DRAWING LIST
ES0.0 ELECTRICAL LEGEND
ES2.0 PARTIAL FLOOR PLAN - POWER
ES4.0 PANEL SCHEDULES
ED1.0 PARTIAL FLOOR PLAN - DEMOLITION
C
LA
R K
KJ
O
S
AR
C H
IT
EC
TS
PY
R
IG
H
T
8 911 2 3 4 5 6 7
A
BB
C D
E
FF
E D
C B
76543211 9800
A th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e in c h o n e in c h o n e in c h o n e in c h o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
U.S. GOVERNMENT PRINTING OFFICE:1984-440-467
DateDate
Solicitation Number
Project No.
DRAWING NO.
Project Title
Drawn: Building Number
Location
DateName Initials
Safety Office
DIR. FACMGT.
COO
CEO
Submittal
Construction
For:
Approved
Approved: Medical Center Director
CADD Information:
Date o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
RevisionsRevisions
VA FORM 08-6231A,JAN 1990
Checked:
S:
\F
MS
\P
RO
JE
CT
S
SE
CT
IO
N\
PR
OJ
EC
TS
\2.
A me ric an La ke \A cti ve
\66 3A
4-
-2
AM
LK
B
R ep lac e H
VA
C (P ha se
-II
)\0
1 P re
-B id
Fo lde rs\
D es ign \C
AD
w ith (N
) D ra wi ng
S he et #s fo r 2
4-
3\E S0
.0.
dw g 9/2
2/2
Ka rim
, N ich ola s C he
/hi m/ his
PL
OT
TE
D
BY
AMERICAN LAKE CAMPUS
ELECTRICAL LEGEND REPLACE HVAC BLDG 19 - PHASE II
NCK
BB
9/22/22
663A4-24-203
ES0.0Approved: Chief Engineer
OFFICE
OFFICETLT
RECORDS
TLT
BUILDING 19 BUILDING 20
3 4
5 6 8 10 11 13
G
F
E
B
9 127
D
C
A
DEMOLITION NOTES:
1. SCHEDULE ALL ELECTRICAL SYSTEM OUTAGES WITH VA.
2. NOT ALL ELECTRICAL SYSTEMS ARE SHOWN. CONTRACTOR SHALL VISIT
SITE TO DETERMINE THE SCOPE OF ELECTRICAL DEMOLITION REQUIRED
AND INCLUDE ALL COSTS IN BID.
3. ELECTRICAL CIRCUITS SERVING EQUIPMENT BEYOND DEMOLITION
BOUNDARY SHALL REMAIN IN SERVICE. REROUTE CIRCUITS TO PROVIDE
CLEARANCE FOR THE CONSTRUCTION OF THIS PROJECT.
4. CONDUCTORS IN DEMOLITION AREA SHALL BE REMOVED BACK TO THE
SOURCE OR LAST ENERGIZED JUNCTION.
5. REROUTE CIRCUITS IN THE PATHWAY OF NEW DUCTWORK AND PIPING
ROUTES. CONTRACTOR TO VISIT SITE, DETERMINE WORK REQUIRED AND
INCLUDE COSTS IN BID.
6. DE-ENERGIZE/MAKE SAFE BEFORE PERFORMING ELEC. DEMO
7. LOTO CIRCUITS AT PANELBOARD 19M
PB
EXISTING TO REMIAN
TO MH23
EXISTING TO REMAIN
(2) 2" COMMUNICATION CONDUITS
W/TELECOM CABLES
EXISTING TO REMIAN
TELECOM BOARD
EXISTING TO REMAIN TELECOM
CABLES
EXISTING TO REMIAN
FIRE ALARM TERMINAL
CABINET BUILDING 19/20
FEED FROM BUILDING #18.
EXISTING CONCRETE SLAB
GRADE - TYPICAL
1-HP1B EXISTING
1-HP1A EXISTING
EXISTING CONCRETE SLAB
GRADE MEP - SEE 2/A4.00
1-HP2B EXISTING
1-HP2A EXISTING
NO WORK
SCALE:
N 1/8" = 1'-0"
PARTIAL FLOOR DEMOLITION PLAN - ELECTRICAL
C
LA
R K
KJ
O
S
AR
C H
IT
EC
TS
PY
R
IG
H
T
8 911 2 3 4 5 6 7
A
BB
C D
E
FF
E D
C B
76543211 9800
A th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e in c h o n e in c h o n e in c h o n e in c h o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
U.S. GOVERNMENT PRINTING OFFICE:1984-440-467
DateDate
Solicitation Number
Project No.
DRAWING NO.
Project Title
Drawn: Building Number
Location
DateName Initials
Safety Office
DIR. FACMGT.
COO
CEO
Submittal
Construction
For:
Approved
Approved: Medical Center Director
CADD Information:
Date o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
RevisionsRevisions
VA FORM 08-6231A,JAN 1990
Checked:
S:
\F
MS
\P
RO
JE
CT
S
SE
CT
IO
N\
PR
OJ
EC
TS
\2.
A me ric an La ke \A cti ve
\66 3A
4-
-2
AM
LK
B
R ep lac e H
VA
C (P ha se
-II
)\0
1 P re
-B id
Fo lde rs\
D es ign \C
AD
w ith (N
) D ra wi ng
S he et #s fo r 2
4-
3\E D1
.0.
dw g 9/2
2/2
Ka rim
, N ich ola s C he
/hi m/ his
PL
OT
TE
D
BY
AMERICAN LAKE CAMPUS
PARTIAL FLOOR PLAN - DEMOLITION REPLACE HVAC BLDG 19 - PHASE II
NCK
BB
9/22/22
663A4-24-203
ED1.0Approved: Chief Engineer
WAQAS
MECH EQUIP
3 4
5 6 8 10 11 13
G
F
E
B
9 127
D
C
A
UP
EXISTING MAS RECORDS
1A02A
WOMEN'S TLT
1A01B
MY HEALTHEVET
1A04
ROI
1A09
ROI/RECEPTION
1A01A
OFFICE
1A10
OFFICE
1A12
OFFICE
1A12A
OFFICE
1A14
OFFICE
1A16
OFFICE
1A16A
OFFICE
1A18
OFFICE
1A20
768 SF
HIMS
1A11
WORK ROOM
1A15
OFFICE
1A17
CONFERENCE ROOM
1A21
CODERS
1A03
SUPERVSR
1A03A
EXISTING MECHANICAL ROOM
1A35
MAIL ROOM
1A42
RECORDS
1A34
EXISTING TOILET
002A
TELECOM - 1
001A
HKG
1A22PASSAGE
1A19
WAITING
1A02
EXISTING OFFICE
VESTIBULE
1A01
PSGE
1A00
LOADING
DOCK
DN
DN
BUILDING 19 BUILDING 20
FLAG NOTES:
DEENERGIZE / LOTO CIRCUIT AT PANELBOARD 19M
REMOVE / REPLACE SERVICE DISCONNECT TO AIR-CONDITIONING
SPLIT SYSTEM 1-HP2B AND ASSOCIATED SYSTEM COMPONENTS
REMOVE / REPLACE SERVICE DISCONNECT TO AIR-CONDITIONING
SPLIT SYSTEM 1-HP2A AND ASSOCIATED SYSTEM COMPONENTS
INSTALL (N) CONDUCTOR CIRCUIT FROM EQUIPMENT PAD LOCATION
BACK TO PANELBOARD 19M
COORDINATE DDC CONTROLS AND BACNET NETWORKING TO
GATEWAY WITH MECHANICAL
19M
CB PB
EXISTING PADMOUNT XFMR 750 KVA
4160V-208Y/120V, 3Ø, 4W
19A
19MDP
TO MH23SEE ONE LINE
DIAGRAM
BLDG. SERVICE DISC. CB
1000A, 208Y/120V, 3Ø, 4W
EXISTING TELECOM BOARD
WP
M
19X
19PB
DOOR POWER
A-41
DOOR POWER
A-41
BUILDING 20
TEMPORARY POWER:
PROVIDE A PORTABLE GENERATOR
TO POWER BUILDING 19 DURING THE
POWER CUTOVER PERIOD. MINIMUM
SIZE TO BE 45KVA, 208Y/120V, 3Ø, 4W.
WPWP
WP
GFCI
GFCI
GFCI
1-HP1B
1-FCU1
1-FCU2
1-FCU3
1-FCU4
1-FCU7
1-FCU9
1-FCU8
1-FCU6
1-FCU10
1-FCU5
1-HP2A
1-BC2
43/43A, 208V, 3Ø
M-38WP
43/43A, 208V, 3Ø M-32
1-1EF1
ON ROOF
1 / 6 HP, 115V
WP
M-41
4.4A, 208V, 3Ø M-26
1.4A, 208V, 1Ø M-22
3.4A, 208V, 1Ø M-22 3.4A, 208V, 1Ø
M-22
3.4A, 208V, 1Ø M-18
3.4A, 208V, 1Ø M-18
3.4A, 208V, 1Ø M-18
1.4A, 208V, 1Ø M-14
3.4A, 208V, 1Ø M-14
0.5A, 208V, 1Ø M-37
1.3A, 208V, 1Ø M-14 U-5
U-3 U-2
U-1DDC/HVAC CONTROL
POWER U-41
A-2
A-2
A-2
A-2
A-4
A-4
A-19
A-4
A-6
A-6
A-6 A-4
A-8 A-8 A-10
A-10 A-14
A-14
A-12 A-16 A-20
A-18
A-18 A-20 A-24
A-22
A-26 A-26
A-24
A-21
A-28 A-28
A-28
U-39
FCP
A-30
A-30
A-6
A-6
A-32 A-34A-32
A-34 A-32A-34A-32
A-34 A-36
A-38A-36 A-36
A-38 A-38
A-40 A-42
A-42
A-40
A-19
A-21
A-19
A-23A-25 A-27
A-23
A-25
A-27
A-29 A-31
A-31
A-31
A-29
A-29
A-31
J J
DOOR POWER
A-41J
1-HP1A
13A, 208V, 1Ø
M-6WP
1-AC1
1.0A, 208V, 1Ø
M-10
HW
4.5KW, 208V, 1Ø
M-2
EXISTING MANHOLE
~80'-0"
SEE ONE LINE DIAGRAM
A-18 J
U-4
19U
DOOR POWER
A-41J
J
WPA-6
ACCESS CONTROL
POWER A-35
1-HP2B
ES4.0
HVAC EQUIPMENT WIRING
SCHEDULE
UNIT WIRING
1-FCU6 3/4", 2#10 & #10G.
1-FCU7 3/4", 3#10 & #10G.
1-FCU8 3/4", 2#10 & #10G.
1-FCU9 3/4", 2#10 & #10G.
1-FCU10 3/4", 2#10 & #10G.
C
LA
R K
KJ
O
S
AR
C H
IT
EC
TS
PY
R
IG
H
T
8 911 2 3 4 5 6 7
A
BB
C D
E
FF
E D
C B
76543211 9800
A th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e in c h o n e in c h o n e in c h o n e in c h o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
U.S. GOVERNMENT PRINTING OFFICE:1984-440-467
DateDate
Solicitation Number
Project No.
DRAWING NO.
Project Title
Drawn: Building Number
Location
DateName Initials
Safety Office
DIR. FACMGT.
COO
CEO
Submittal
Construction
For:
Approved
Approved: Medical Center Director
CADD Information:
Date o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
RevisionsRevisions
VA FORM 08-6231A,JAN 1990
Checked:
S:
\F
MS
\P
RO
JE
CT
S
SE
CT
IO
N\
PR
OJ
EC
TS
\2.
A me ric an La ke \A cti ve
\66 3A
4-
-2
AM
LK
B
R ep lac e H
VA
C (P ha se
-II
)\0
1 P re
-B id
Fo lde rs\
D es ign \C
AD
w ith (N
) D ra wi ng
S he et #s fo r 2
4-
3\E S2
.0.
dw g 9/2
2/2
Ka rim
, N ich ola s C he
/hi m/ his
PL
OT
TE
D
BY
SCALE:
N 1/8" = 1'-0"
PARTIAL FLOOR PLAN - POWER
AMERICAN LAKE CAMPUS
PARTIAL FLOOR PLAN - POWER REPLACE HVAC BLDG 19 - PHASE II
NCK
BB
9/22/22
663A4-24-203
ES2.0Approved: Chief Engineer
LA
R K
KJ
O
S
AR
C H
IT
EC
TS
PY
R
IG
H
T
8 911 2 3 4 5 6 7
A
BB
C D
E
FF
E D
C B
76543211 9800
A th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e in c h o n e in c h o n e in c h o n e in c h o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
U.S. GOVERNMENT PRINTING OFFICE:1984-440-467
DateDate
Solicitation Number
Project No.
DRAWING NO.
Project Title
Drawn: Building Number
Location
DateName Initials
Safety Office
DIR. FACMGT.
COO
CEO
Submittal
Construction
For:
Approved
Approved: Medical Center Director
CADD Information:
Date o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
RevisionsRevisions
VA FORM 08-6231A,JAN 1990
Checked:
S:
\F
MS
\P
RO
JE
CT
S
SE
CT
IO
N\
PR
OJ
EC
TS
\2.
A me ric an La ke \A cti ve
\66 3A
4-
-2
AM
LK
B
R ep lac e H
VA
C (P ha se
-II
)\0
1 P re
-B id
Fo lde rs\
D es ign \C
AD
w ith (N
) D ra wi ng
S he et #s fo r 2
4-
3\E S4
.0.
dw g 9/2
2/2
Ka rim
, N ich ola s C he
/hi m/ his
PL
OT
TE
D
BY
SCALE: NOT TO SCALE
DISCONNECT ARRAY AT WEST ELEVATION - DETAIL1
AMERICAN LAKE CAMPUS
PANEL SCHEDULES & DISCONNECT DETAIL REPLACE HVAC BLDG 19 - PHASE II
NCK
BB
9/22/22
663A4-24-203
ES4.0Approved: Chief Engineer
SYMBOL DESCRIPTIONDESCRIPTION
SYMBOLS LEGEND - AIR HANDLING
DRAWING CONSTRUCTION ("FLAG") NOTE
MATCHLINE
REVISION CLOUD (ENCIRCLES DRAWING
CHANGES MADE SINCE THE PREVIOUS RELEASE)
DETAIL REFERENCE
REVISION REFERENCE
NORTH REFERENCE
N
XX.XX
X
SYMBOL
PLAN
DESCRIPTIONDESCRIPTION
SYMBOLS LEGEND - GENERAL
DETAIL IDENTIFICATION NUMBER
SHEET WHERE DETAIL IS DRAWN
X-XX EQUIPMENT IDENTIFIER
10X10
APAD
R
RECTANGULAR TO ROUND TRANSITION
ROUND BRANCH TO ROUND DUCT CONNECTION
ROUND BRANCH TO RECTANGULAR DUCT CONNECTION
RECTANGULAR BRANCH TO RECTANGULAR DUCT
CONNECTION WITH 45° TAPER
ROUND OR RECTANGULAR BRANCH TO ROUND OR
RECTANGULAR DUCT CONNECTION
RECTANGULAR OR ROUND, 90° ELBOW,
R/W OR R/D = 1.5
POSITIVE PRESSURE DUCT - TURNING TOWARD
POSITIVE PRESSURE DUCT - TURNING AWAY
NEGATIVE PRESSURE DUCT - TURNING TOWARD
NEGATIVE PRESSURE DUCT - TURNING AWAY
ROUND DUCT - TURNING TOWARD
ROUND DUCT - TURNING AWAY
FLEXIBLE CONNECTION
ACCESS DOOR (AD) OR ACCESS PANEL (AP)
VOLUME DAMPER
VERTICAL FIRE DAMPER (HORIZONTAL AIRFLOW)
MOTOR OPERATED DAMPER
BACKDRAFT DAMPER
FLEXIBLE DUCT
EQUIPMENT WITH EQUIPMENT IDENTIFICATION
THERMOSTAT
CEILING SUPPLY DIFFUSER
ROUND, 90° ELBOW, R/W OR R/D = 1.5
RECTANGULAR, 90° ELBOW, R/W OR R/D = 1.5
45° BRANCH CONNECTION
TRANSITION OR REDUCER - NOTED FOT (FLAT ON TOP) OR
FOB (FLAT ON BOTTOM) IF REQUIRED
INCLINE RISE (R) OR DROP (D) IN DIRECTION OF ARROW
PLAN
CEILING RETURN DIFFUSER
AIRFLOW, SUPPLY
AIRFLOW, RETURN
T
EQ-ID
DIFFUSER IDENTIFIER
DIFFUSER TYPE MARK
AIR FLOW (CFM)
M
BDD
140° POTABLE HOT WATER
120° POTABLE HOT WATER120°HW
140°HW
COLD WATER
HOT WATER
HOT WATER CIRCULATING
ID INDIRECT DRAIN
VENT
SOIL OR WASTE
THERMOMETER
SYMBOL DESCRIPTIONDESCRIPTION
SYMBOLS LEGEND - PIPING
PLAN & DIAGRAM
CAP
GATE VALVE
RELIEF VALVE
CHECK VALVE
EXISTING TO BE REMOVED (CROSSED)
HEAVY LINEWEIGHT INDICATES NEW WORK
POINT OF CONNECTION (POC) BETWEEN NEW
AND EXISTING
DIAGRAMPLAN
PLAN
PIPE TURNING DOWN / AWAY
PIPE TURNING UP / TOWARDS
PIPING OR DUCTED AIRFLOW
NON-DUCTED AIRFLOW
ELECTRICAL CONNECTION
ELECTRIC MOTOR/STARTER ASSEMBLY
ELECTRIC MOTOR OPERATOR (VALVES AND DAMPERS)
SYMBOL DESCRIPTIONDESCRIPTION
SYMBOLS LEGEND - PIPING & AIRFLOW DIAGRAMS
PLAN & DIAGRAM
M
M
MECHANICAL DRAWING LIST
MH0.0 MECHANICAL LEGEND, GENERAL NOTES, ABBREVIATIONS & DRAWING LIST
MH0.1 HVAC SCHEDULES
MD1.0 PARTIAL FLOOR PLAN - DEMO
MH2.1 PARTIAL FLOOR PLAN - HVAC & PIPING
MH2.2 SEQUENCE OF OPERATIONS & POINTS LIST
MH3.0 PARTIAL ROOF PLAN - HVAC
MH4.0 ZONING PLAN - HVAC
MH5.0 HVAC DETAILS
ENGLISH TO METRIC CONVERSION CHART
AIR FLOW LENGTH POWER
CFM Liters/Sec. Inches Millimeters Horsepower Killowatts 100 47.2 1/2" 13 mm 1/50 HP 0.01 KW 500 236.0 3/4" 19 mm 1/30 HP 0.02 KW
1000 472.0 1" 25 mm 1/6 HP 0.12 KW 15560 7344.3 1 1/4" 32 mm 1/3 HP 0.25 KW
1 1/2" 38 mm 1/8 HP 0.09 KW WATER FLOW 2" 51 mm 1/4 HP 0.19 KW
GPM Liters/Sec. 2 1/2" 64 mm 1/2 HP 0.37 KW 1 0.0631 3" 76 mm 3/4 HP 0.56 KW
100 6.31 3 1/2" 89 mm 1 HP 0.75 KW 4" 102 mm 1 1/2 HP 1.12 KW
TEMPERATURE 5" 127 mm 2 HP 1.49 KW Degrees F Degrees C 6" 152 mm 5 HP 3.73 KW
50° 10° 8" 203 mm 7 1/2 HP 5.59 KW 95° 35° 8 3/4" 222 mm 10 HP 7.45 KW 239° 115° 10" 254 mm 15 HP 11.18 KW
12" 305 mm 30 HP 22.35 KW PRESSURE 14" 356 mm
Feet KPa 24" 610 mm 1 30KPa 36" 914 mm
20 600KPa 38" 965 mm 40" 1016 mm
PRESSURE 48" 1219 mm PSIG KPa 60" 1524 mm
10 69KPa 70" 1778 mm 50 345KPa 96" 2438 mm
100 690KPa
STEAM FLOW - Lbs/Hr.
1000 #/Hr. 0.126 Kg/Sec.
ACTUATOR
AIRFLOW MEASURING UNIT
CURRENT TRANSDUCER
CURRENT SWITCH
DIFFERENTIAL PRESSURE
DIFFERENTIAL PRESSURE SWITCH
FREEZESTAT
SPEED
SMOKE DETECTOR
STATIC PRESSURE SENSOR
START/STOP
TEMPERATURE SENSOR
AVERAGING TEMPERATURE SENSOR
VARIABLE FREQUENCY DRIVE
ALARM
VFD
DUCT TEMPERATURE SENSOR
ELECTRIC ACTUATOR
SYMBOLS LEGEND - CONTROLS
ABBREVIATIONS
A AIR, AMP
AC AIR CONDITIONING UNIT
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AL ALUMINUM, ACOUSTICAL LINING
ARRGT ARRANGEMENT
ATM ATMOSPHERE
BDD BACKDRAFT DAMPER
BFF BELOW FINISHED FLOOR
BFP BACKFLOW PREVENTER
BLDG BUILDING
BHP BRAKE HORSEPOWER
BOB BOTTOM OF BEAM
BOD BOTTOM OF DUCT
BOS BOTTOM OF STEEL
BTUH BRITISH THERMAL UNITS PER
HOUR
CAP CAPACITY
CC COOLING COIL
CLG CEILLING, COOLING
CD CEILING DIFFUSER
CFM CUBIC FEET PER MINUTE
CI CAST IRON
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CNTFGL CENTRIFUGAL
CO CLEANOUT
CONC CONCRETE
COND CONDENSATE
CONT CONTINUE, CONTROL
CP CIRCULATING PUMP
CRU CONDENSATE RETURN UNIT
CU FT CUBIC FEET
CU CONDENSING UNIT
CV CONSTANT VOLUME
CVTR CONVERTER
CW COLD WATER
dB DECIBLES
DB DRY BULB
DCVA DOUBLE CHECK VALVE ASSEMBLY
DF DRINKING FOUNTAIN
DMPR DAMPER
DN DOWN
DS DOWNSPOUT
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EF EXHAUST FAN
EFF EFFICIENCY
EG EXHAUST GRILLE
EL ELEVATION
EWT ENTERING WATER TEMPERATURE
EXH EXHAUST
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR, EXTERNAL
F FAHRENHEIT, FIRE LINE
FD FIRE DAMPER, FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FLR FLOOR
FLTR FILTER
FM FLOW METER
FOB FLAT ON BOTTOM
FOT FLAT ON TOP
FPM FEET PER MINUTE
FPS FEET PER SECOND
FSD FIRE SMOKE DAMPER
FT FEET, FAN TERMINAL
FV FACE VELOCITY
GA GAGE
GAL GALLONS
GALV GALVANIZED
GPM GALLONS PER MINUTE
H HUMIDIFIER
HB HOSE BIBB
HC HEATING COIL
HD HEAD
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER, HEAT PUMP
HW HOT WATER
HWC HOT WATER CIRCULATING
ID INSIDE DIAMETER, INDIRECT DRAIN
IE INVERT ELEVATION
INT INTERIOR
KW KILOWATT
LAT LEAVING AIR TEMPERATURE
LB POUND, LINEAR BAR
LD LINEAR DIFFUSER
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MBH THOUSAND BTU PER HOUR
MD MANUAL DAMPER
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MOD MOTOR OPERATED DAMPER
MTR MOTOR
NC NORMALLY CLOSED
NIC NUMBER, NORMALLY OPEN
NTS NOT TO SCALE
OA OUTDOOR AIR
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
ORD OVERFLOW ROOF DRAIN
P PUMP, PLUMBING
PD PRESSURE DROP
POC POINT OF CONNECTION
P/T PRESSURE/TEMPERATURE
PVC POLYVINYL CHLORIDE
PR PUMPED RETURN
RA RETURN AIR
REF REFERENCE
REQD REQUIRED
RG RETURN GRILLE
RH RELIEF HOOD
RPM REVOLUTIONS PER MINUTE
SA SUPPLY AIR
SD STORM DRAIN, SMOKE DAMPER,
SUPPLY DIFFUSER
SG SUPPLY GRILLE
SL SOUNDLINING
SP STATIC PRESSURE
SS STAINLESS STEEL, SANITARY
SEWER
T THERMOSTAT
TG TRANSFER GRILLE
TOD TOP OF DUCT
TP TRAP PRIMER, TOTAL PRESSURE
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
V VENT, VOLT
VA VALVE
VTR VENT THROUGH ROOF
VRF VARIABLE REFRIGERANT FLOW
W WASTE, WATER, WATT
WB WET BULB
WG WATER GAGE
WH WATER HEATER, WALL HYDRANT
GENERAL NOTES
1. THE FULL SCOPE OF THE MECHANICAL WORK IS THE TOTAL OF WORK SHOWN ON THE PLANS AND
CALLED FOR IN THE SPECIFICATIONS. IN CASE OF CONFLICT, THE SPECIFICATIONS SHALL GOVERN.
PROVIDE A…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .