This document is a set of architectural and engineering drawings for a kitchenette installation project at Building 2479, Fort Bliss, Texas. The project involves renovation work on the first and second floors of the facility, including demolition, new construction, plumbing, mechanical, and electrical work.

The drawings include site plans, demolition work plans for both floors with keyed notes indicating specific removal tasks (wall demolition, grid and ceiling panel removal, electrical outlet replacement, pool relocation, core drilling for sewer lines, wood paneling removal, and drywall installation). New work plans detail kitchen specifications including room finishes, plumbing fixtures, cabinet installations with specific measurements, countertop materials, appliance specifications, and floor finishes. Mechanical work plans show kitchen hood installation with a schedule indicating a PS-13 Gaubree model hood with specifications including 385/900 volts, 5.5 amps, 1900 watts, 0.7 power factor, 120 volt cycles, and under cabinet mounting. Plumbing work plans detail first and second floor installations including water lines, drain connections, and basement sections. Electrical demolition and new work plans identify outlet replacements, under-cabinet lighting, power system modifications, and panel installations. The document is organized as 13 sheets total and supervised by the Directorate of Public Works Engineering Services Division at Fort Bliss, Texas, with contractor contact information referenced as W911SGXXD0XX and TO: W911SGXXF0XXX.

View the file

Other files

File Type Posted
Attachment 14-Project closeout report (2008) W911RX26BA002.pdf PDF
Attachment 13-Ltd Asbestos-Lead Survey_Bldg-2479_20080704 W911RX26BA002.pdf PDF
Solicitation Amendment 03 W911RX26BA0020003.pdf PDF
Solicitation Amendment 03 W911RX26BA0020003 SF 30.pdf PDF
Attachment 02-Asbestos-Lead Survey_Bldg-2479 W911RX26BA002.pdf PDF
Solicitation Amendment 02 W911RX26BA0020002.pdf PDF
Attachment 11-Updated Industry QA 22JUL2026 W911RX26BA002.pdf PDF
Solicitation Amendment 02 W911RX26BA0020002 SF 30.pdf PDF
Attachment 12- As Built Drawings W911RX26BA002.pdf PDF
Attachment 01-SOW B2479 Kitchenette 8A Rev2 07172026 W911RX26BA002.pdf PDF
Solicitation Amendment W911RX26BA0020001 SF 30.pdf PDF
Attachment 11-Industry QA 07152026 W911RX26BA002.pdf PDF
Solicitation Amendment W911RX26BA0020001.pdf PDF
Attachment 04-DPW-RFI Template Blank Form V.1.2 W911RX26BA002.pdf PDF
Attachment 10-26-0345_Environmental Review_11B 10118 6P W911RX26BA002.pdf PDF
Attachment 03-ENG_FORM_4288-R W911RX26BA002.pdf PDF
Attachment 08-Material Approval Submittal_-FILLABLE W911RX26BA002.pdf PDF
Attachment 02-Asbestos-Lead Survey Bldg 2478_20120209 W911RX26BA002.pdf PDF
Attachment 06-iWATCH Trng for Contractors 20190613 W911RX26BA002.pdf PDF
Attachment 01-SOW Rev2 06-03-26 W911RX26BA002.pdf PDF
Attachment 05-FIRE PREVENTION CONSTRUCTION GUIDE 2025 W911RX26BA002.pdf PDF
Solicitation - W911RX26BA002.pdf PDF
Attachment 09-Davis-Bacon Act WD TX20260245 W911RX26BA002.pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D P

W

FO

R T

B

LI

SS

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

COVER SHEET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text

FORT BLISS, TEXAS

AutoCAD SHX Text

INDEX OF DRAWINGS

AutoCAD SHX Text

NO.

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

BUILDING 2479 KITCHENETTE INSTALLATION

AutoCAD SHX Text

PROJECT LOCATION MAP

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text N

AutoCAD SHX Text

PROJECT LOCATION

AutoCAD SHX Text 1 = COVER SHEET 2 = SITE PLAN 3 = DEMOLITION WORK PLAN - 1ST FLOOR 4 = DEMOLITION WORK PLAN - 2ND FLOOR 5 = NEW WORK PLAN - 1ST FLOOR 6 = NEW WORK PLAN - 2ND FLOOR 7 = MECHANICAL WORK PLANS - 1ST FLOOR 8 = MECHANICAL WORK PLANS - 2ND FLOOR 9 = PLUMBING WORK PLANS - 1ST FLOOR & BASEMENT 10= PLUMBING WORK PLANS - 2ND FLOOR 11= ELECTRICAL WORK PLANS - 1ST FLOOR 12= ELECTRICAL WORK PLANS - 2ND FLOOR 13= PROJECT INFORMATION SIGNAGE DETAIL

AutoCAD SHX Text

CVRSHT

AutoCAD SHX Text 04/23/2026

AutoCAD SHX Text 11B-10118-6P

AutoCAD SHX Text L.L.

AutoCAD SHX Text L.L.

AutoCAD SHX Text

BUILDING 2479 KITCHENETTE INSTALLATION

AutoCAD SHX Text

SHANNON VAN VALZAH RD.

AutoCAD SHX Text

CHAFFEE RD.

AutoCAD SHX Text

HAAN RD.

AutoCAD SHX Text

STENNIS ST.

AutoCAD SHX Text

CARRINGTON RD.

AutoCAD SHX Text

BLDG. 2479

P

W

FO

R T

B

LI

SS

N

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-100

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text 04/23/2026

AutoCAD SHX Text L.L.

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text L.L.

AutoCAD SHX Text

AutoCAD SHX Text

SITE PALN

AutoCAD SHX Text

SCALE: 1"=40'

AutoCAD SHX Text

BUILDING 2479 KITCHENETTE INSTALLATION

AutoCAD SHX Text

CONSTRUCTION LIMITS

AutoCAD SHX Text

LAY-DOWN AREA

AutoCAD SHX Text

HAAN RD.

AutoCAD SHX Text

CARRINGTON RD.

AutoCAD SHX Text

BLDG. 2479

AutoCAD SHX Text

GENERAL NOTES (EXISTING CONDITIONS)

AutoCAD SHX Text

1. CONTRACTOR SHALL MAINTAIN AND CLEAN CONSTRUCTION AREA CONTRACTOR SHALL MAINTAIN AND CLEAN CONSTRUCTION AREA AS PER CONTRACT AND SAFETY RECOMMENDATIONS. 2. CONTRACTOR SHALL PROVIDE AND FURNISH TRAFFIC CONTROL CONTRACTOR SHALL PROVIDE AND FURNISH TRAFFIC CONTROL FOR AREA ADJACENT TO CONSTRUCTION AREA. CONTRACTOR CONTRACTOR SHALL PROVIDE ALL REQUIRED TRAFFIC CONTROL PLANS. ALL SIGNS, BARRICADES, CHANNELIZATION DEVICES, SIGN FRAMES AND ERECTION OF SUCH DEVICES SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL TRAFFIC CONTROL AUTHORITY. 3. BUILDING WILL BE OCCUPIED DURING CONSTRUCTION. PROVIDE BUILDING WILL BE OCCUPIED DURING CONSTRUCTION. PROVIDE ACCESS/TEMPERATURE COOLING/HEATING IF NECESSARY DURING PERIODS AC AND HEATER ARE DOWN. CONTRACTOR SHALL PROVIDE BUILDING ACCESS TO USER. 4. CONTRACTOR SHALL PROVIDE VEHICULAR ACCESS TO PARKING CONTRACTOR SHALL PROVIDE VEHICULAR ACCESS TO PARKING SPACES. 5. ALL WORK SHALL COMPLY WITH ALL MANUFACTURER'S ALL WORK SHALL COMPLY WITH ALL MANUFACTURER'S SPECIFICATIONS/RECOMMENDATIONS, FEDERAL, STATE, AND LOCAL REGULATIONS/CODES. 6. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS ON SITE AND INDICATE CHANGES AS THE PROJECT PROGRESSES. 7. NO OBSTRUCTIONS WILL BE PERMITTED WITHIN THREE FEET OF NO OBSTRUCTIONS WILL BE PERMITTED WITHIN THREE FEET OF FIRE HYDRANTS. 8. ANY DEMOLITION DEBRIS SUSPECTED TO CONTAIN HAZARDOUS ANY DEMOLITION DEBRIS SUSPECTED TO CONTAIN HAZARDOUS MATERIALS, SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER REPRESENTATIVE PRIOR TO CONTINUING ANY ADDITIONAL WORK. 9. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ALL CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ALL EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO EXISTING ELECTRICAL CONDUIT, GAS LINES, WIRES, ETC., AS REQUIRED TO ALLOW FOR CONSTRUCTION. 10. CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING EQUIPMENT, MATERIALS AND FINISHES THAT ARE TO REMAIN, AND WITHOUT NECESSARY DAMAGE. ANY DAMAGES SHALL BE REPLACED OR RESTORED WITHOUT ADDITIONAL COST TO THE GOVERNMENT. 11. ALL REMOVED EQUIPMENT SHALL BE REINSTALLED AND ALL REMOVED EQUIPMENT SHALL BE REINSTALLED AND TESTED IN THE PRESENCE OF A CONTRACTING OFFICER REPRESENTATIVE. 12. CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS REQUIRES A MINIMUM OF 60% OF CONSTRUCTION WASTE AND DEMOLITION MATERIALS AND DEBRIS BE RECYCLED. IF THE CONTRACTOR HAS A VALID REASON FOR NOT BEING ABLE TO MEET THIS DIVERSION GOAL, THE CONTRACTOR NEEDS TO PRESENT THEIR REASONING IN WRITING TO DPW-ENVIRONMENTAL DIVISION FOR APPROVAL 13. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT LOCATIONS AND QUANTITIES BEFORE COMMENCING WORK. 14. PRIOR TO CONSTRUCTION START, CONTRACTOR SHALL PRIOR TO CONSTRUCTION START, CONTRACTOR SHALL CONDUCT A THOROUGH PHOTOGRAPHIC SURVEY OF THE SITE. CRACKED SIDEWALKS, BROKEN WINDOWS, BENT EQUIPMENT, ETC. THIS INCLUDES INVENTORY OF ALL ITEMS ON SITE AND THEIR CONDITION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RESPONSIBILITY TO REPAIR. 15. ALL SURFACES IN CONTACT WITH NEW WORK THAT ARE ALL SURFACES IN CONTACT WITH NEW WORK THAT ARE DAMAGED DUE TO NEW WORK IN PROGRESS, SHALL BE PATCHED AND REPAIRED AS REQUIRED. 16. EXISTING SITE IMPROVEMENTS DAMAGED BY THE CONTRACTOR EXISTING SITE IMPROVEMENTS DAMAGED BY THE CONTRACTOR SHALL BE REMOVED AND REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. 17. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD REPRESENTATIVE IMMEDIATELY OF ANY CONFLICTS DISCOVERED IN THE FIELD VIA RFI, ASAP TO ALLOW SUFFICIENT TIME TO REVIEW AND RESOLVE THE ISSUE. 18. CONTRACTOR SHALL UTILIZE ALL CONSTRUCTION DOCUMENTS, CONTRACTOR SHALL UTILIZE ALL CONSTRUCTION DOCUMENTS, SCOPE, CONTRACT, SPECIFICATIONS, AND DRAWINGS TO ENSURE ALL CONSTRUCTION, DELIVERABLES, AND RESOURCES ARE DELIVERED TO THE GOVERNMENT. 19. PRIOR TO ANY CHANGE OR MODIFICATION TO THESE PRIOR TO ANY CHANGE OR MODIFICATION TO THESE DRAWINGS DUE TO ACTUAL CONDITIONS, DPW REPRESENTATIVE SHALL BE NOTIFIED FOR REVIEW AND APPROVAL.

AutoCAD SHX Text

LAY-DOWN AREA NOTES

AutoCAD SHX Text

1. LAY-DOWN AREA SHALL BE DESIGNATED PRIOR TO THE START LAY-DOWN AREA SHALL BE DESIGNATED PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL COORDINATE WITH DPW MASTER PLANNING. 2. THE CONTRACTOR SHALL RESTORE ANY ACCESS ROADS AND THE CONTRACTOR SHALL RESTORE ANY ACCESS ROADS AND LAY-DOWN AREAS USED BACK TO THEIR ORIGINAL STABILIZED CONDITION OR BETTER. 3. CONTRACTOR SHALL PROVIDE AND INSTALL ALL EQUIPMENT AND CONTRACTOR SHALL PROVIDE AND INSTALL ALL EQUIPMENT AND SUPPLIES REQUIRED TO SECURE THE TEMPORARY STORAGE AREA.

AutoCAD SHX Text

UTILITY NOTES

AutoCAD SHX Text

1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, WHETHER INDICATED ON THE DRAWING OR NOT, TO VERIFY THE LOCATION, DEPTH, AND CONDITION OF ALL EXITING UTILITIES AND SUBSTRUCTURES AND PROTECT THEM FROM ANY DAMAGE. 2. THE CONTRACTOR SHALL CONTACT ALL THE UTILITY COMPANIES AND CONDUCT ALL NECESSARY FIELD INVESTIGATIONS PRIOR TO ANY EXCAVATION. ANY DAMAGE TO EXISTING UTILITIES SHALL BE PROMPTLY REPAIRED BY THE CONTRACTOR AT NO EXPENSE TO GOVERNMENT. 3. NOTIFY THE DPW REPRESENTATIVE IN WRITING AT LEAST 14 NOTIFY THE DPW REPRESENTATIVE IN WRITING AT LEAST 14 DAYS BEFORE ANY UTILITY OUTAGE OR ROAD CLOSURE.

11B-10118-6P

W

FO

R T

B

LI

SS

AutoCAD SHX Text

DAY ROOM

AutoCAD SHX Text

AutoCAD SHX Text T.V.

AutoCAD SHX Text

AutoCAD SHX Text

GAME ROOM

AutoCAD SHX Text

AutoCAD SHX Text

MAIL

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

COMMO.

AutoCAD SHX Text

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

DEMOLITION WORK PLAN - 1ST FLOOR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-101

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text 04/23/2026

AutoCAD SHX Text L.L.

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text L.L.

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLITION WORK PLAN - 1ST FLOOR

AutoCAD SHX Text

SCALE: 1/4"=1'-0"

AutoCAD SHX Text

BUILDING 2479 KITCHENETTE INSTALLATION

AutoCAD SHX Text

DEMOLITION GENERAL NOTES

AutoCAD SHX Text

DEMOLITION KEYED NOTES

AutoCAD SHX Text

AutoCAD SHX Text MODIFY REFLECTIVE CEILING SYSTEM AS NEEDED FOR NEW HOODS. SEE MECHANICAL DRAWINGS.

AutoCAD SHX Text

AutoCAD SHX Text

REMOVE GRID & CEILING PANELS.

AutoCAD SHX Text

AutoCAD SHX Text DEMOLISH WALL AS NEEDED TO ALLOW PENETRATION OF APPROXIMATELY 8" ROUND DUCT CONNECTED TO THE ANSUL SYSTEM HOOD.

AutoCAD SHX Text

AutoCAD SHX Text

REPLACE EXISTING ELECTRICAL OUTLET AND WIRE. REPLACE WITH A 208V/240V OUTLET.

AutoCAD SHX Text

AutoCAD SHX Text

RELOCATE POOL CUE RACK, COORDINATE WITH COR FOR FUTURE RELOCATION.

AutoCAD SHX Text

AutoCAD SHX Text

PERFORM DIAGNOSTIC CORE DRILLING TO LOCATE SEWER LINE.

AutoCAD SHX Text

AutoCAD SHX Text

REMOVE EXISTING WOOD PANELING AND MIRROR.

AutoCAD SHX Text

AutoCAD SHX Text

REMOVE DRYWALL TO INSTALL STAINLESS STEEL SINK AND FAUCET AS NEEDED.

AutoCAD SHX Text

1. CONTRACTOR MUST RECEIVER AS ASBESTOS SURVEY CONTRACTOR MUST RECEIVER AS ASBESTOS SURVEY REPORT AND LEAD BASE PAINT SURVEY REPORT PRIOR TO BID. CONTRACTOR MUST REQUEST REPORT IN WRITING BEFORE BID DATE. 2. CONTRACTOR WILL BE RESPONSIBLE FOR AIR CONTRACTOR WILL BE RESPONSIBLE FOR AIR MONITORING & ABATEMENT. ALL REGULATIONS WILL BE MET. 3. CONTRACTOR TO VISIT SITE PRIOR TO BID. CONTRACTOR TO VISIT SITE PRIOR TO BID. 4. THE CONTRACTOR IS RESPONSIBLE TO PROTECT ALL THE CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING EQUIPMENT, MATERIALS AND FINISHES THAT ARE TO REMAIN WITHOUT UNNECESSARY DAMAGE. ANY DAMAGE TO SAME SHALL BE REPLACED OR RESTORED WITHOUT ADDITIONAL COST TO THE GOVERNMENT. 5. DEMOLISH GYPSUM BOARD AS NEEDED FOR DEMOLISH GYPSUM BOARD AS NEEDED FOR ELECTRICAL CONDUIT, COORDINATE WITH ELECTRICAL. 6. NOTE NOT ALL KEYED NOTES ARE USED ON THIS NOTE NOT ALL KEYED NOTES ARE USED ON THIS SHEET.

W

FO

R T

B

LI

SS

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

TV ROOM

AutoCAD SHX Text

AutoCAD SHX Text

LAUNDRY

AutoCAD SHX Text

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

DEMOLITION WORK PLAN - 2ND FLOOR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-102

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text 04/23/2026

AutoCAD SHX Text L.L.

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text L.L.

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLITION WORK PLAN - 2ND FLOOR

AutoCAD SHX Text

SCALE: 3/16"=1'-0"

AutoCAD SHX Text

BUILDING 2479 KITCHENETTE INSTALLATION

AutoCAD SHX Text

DEMOLITION GENERAL NOTES

AutoCAD SHX Text

DEMOLITION KEYED NOTES

AutoCAD SHX Text

AutoCAD SHX Text MODIFY REFLECTIVE CEILING SYSTEM AS NEEDED FOR NEW HOODS. SEE MECHANICAL DRAWINGS.

AutoCAD SHX Text

AutoCAD SHX Text

REMOVE GRID & CEILING PANELS.

AutoCAD SHX Text

AutoCAD SHX Text DEMOLISH WALL AS NEEDED TO ALLOW PENETRATION OF APPROXIMATELY 8" ROUND DUCT CONNECTED TO THE ANSUL SYSTEM HOOD.

AutoCAD SHX Text

AutoCAD SHX Text

REPLACE EXISTING ELECTRICAL OUTLET AND WIRE. REPLACE WITH A 208V/240V OUTLET.

AutoCAD SHX Text

AutoCAD SHX Text

RELOCATE POOL CUE RACK, COORDINATE WITH COR FOR FUTURE RELOCATION.

AutoCAD SHX Text

AutoCAD SHX Text

PERFORM DIAGNOSTIC CORE DRILLING TO LOCATE SEWER LINE.

AutoCAD SHX Text

AutoCAD SHX Text

REMOVE EXISTING WOOD PANELING AND MIRROR.

AutoCAD SHX Text

AutoCAD SHX Text

REMOVE DRYWALL TO INSTALL STAINLESS STEEL SINK AND FAUCET AS NEEDED.

AutoCAD SHX Text

1. CONTRACTOR MUST RECEIVER AS ASBESTOS SURVEY CONTRACTOR MUST RECEIVER AS ASBESTOS SURVEY REPORT AND LEAD BASE PAINT SURVEY REPORT PRIOR TO BID. CONTRACTOR MUST REQUEST REPORT IN WRITING BEFORE BID DATE. 2. CONTRACTOR WILL BE RESPONSIBLE FOR AIR CONTRACTOR WILL BE RESPONSIBLE FOR AIR MONITORING & ABATEMENT. ALL REGULATIONS WILL BE MET. 3. CONTRACTOR TO VISIT SITE PRIOR TO BID. CONTRACTOR TO VISIT SITE PRIOR TO BID. 4. THE CONTRACTOR IS RESPONSIBLE TO PROTECT ALL THE CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING EQUIPMENT, MATERIALS AND FINISHES THAT ARE TO REMAIN WITHOUT UNNECESSARY DAMAGE. ANY DAMAGE TO SAME SHALL BE REPLACED OR RESTORED WITHOUT ADDITIONAL COST TO THE GOVERNMENT. 5. DEMOLISH GYPSUM BOARD AS NEEDED FOR DEMOLISH GYPSUM BOARD AS NEEDED FOR ELECTRICAL CONDUIT, COORDINATE WITH ELECTRICAL. 6. NOTE NOT ALL KEYED NOTES ARE USED ON THIS NOTE NOT ALL KEYED NOTES ARE USED ON THIS SHEET.

W

FO

R T

B

LI

SS

AutoCAD SHX Text

DAY ROOM

AutoCAD SHX Text

AutoCAD SHX Text

GAME ROOM

AutoCAD SHX Text

AutoCAD SHX Text

MAIL

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1'-8"

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text 2'-10"

AutoCAD SHX Text 7'-6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 4'-8"

AutoCAD SHX Text 2'-10"

AutoCAD SHX Text

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

NEW WORK PLAN - 1ST FLOOR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-103

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text 04/23/2026

AutoCAD SHX Text L.L.

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text L.L.

AutoCAD SHX Text

AutoCAD SHX Text

NEW WORK PLAN - 1ST FLOOR

AutoCAD SHX Text

SCALE: 1/4"=1'-0"

AutoCAD SHX Text

BUILDING 2479 KITCHENETTE INSTALLATION

AutoCAD SHX Text

NEW WORK KEYED NOTES

AutoCAD SHX Text

1. UNLESS NOTED OTHERWISE, ALL NEW INTERIOR SURFACES SHALL BE PAINTED. REFERENCE THE ROOM SCHEDULE FOR FINISHES. WALLS, DOORS, ALL DOOR FRAMES. 2. PATCH AND REPAIR ALL AREAS DAMAGED BY DEMOLITION WORK PRIOR TO APPLYING NEW CONSTRUCTION FINISHES. PATCH HOLES IN WOOD WITH A TWO PART EPOXY WOOD FILLER AND PREPARE SURFACE FOR PAINT. 3. EXISTING EXTERIOR FINISHES SHALL REMAIN, PROTECT FROM DAMAGE DURING DEMOLITION AND NEW CONSTRUCTION ACTIVITIES. 4. NEW SYSTEMS FURNITURE AND MODULAR ARCHITECTURAL NEW SYSTEMS FURNITURE AND MODULAR ARCHITECTURAL WALL ARE NOT A PART OF THIS CONTRACT. ANY FURNITURE AND/OR WALL INDICATED IN THE FLOOR PLANS ARE FOR CONVENIENCE OF THE CONTRACTOR TO IDENTIFY FURNITURE LOCATIONS. 5. REFERENCE ALL MEP DRAWINGS. REFERENCE ALL MEP DRAWINGS. 6. INSTALL UNDER-CABINET LIGHTING UNDERNEATH ALL INSTALL UNDER-CABINET LIGHTING UNDERNEATH ALL WALL CABINETS. REFERENCE ELECTRICAL DRAWINGS. 7. SEE ROOM & MATERIAL FINISH SCHEDULE.SEE ROOM & MATERIAL FINISH SCHEDULE.

AutoCAD SHX Text

ROOM FINISH SCHEDULE AND PLUMBING FIXTURES (OR EQUAL)

AutoCAD SHX Text

NEW WORK GENERAL NOTES

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text 3'

AutoCAD SHX Text 3'

AutoCAD SHX Text 4'

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 3'

AutoCAD SHX Text 4'

AutoCAD SHX Text 4'

AutoCAD SHX Text 4'

AutoCAD SHX Text

AutoCAD SHX Text

CABINET ELEVATION

AutoCAD SHX Text

SCALE: 3/8"=1'-0"

AutoCAD SHX Text

(SEE FLOOR PLAN & ROOM FINISH SCHEDULE FOR DETAILS)

AutoCAD SHX Text

AutoCAD SHX Text

CABINET ELEVATION

AutoCAD SHX Text

SCALE: 3/8"=1'-0"

AutoCAD SHX Text

(SEE FLOOR PLAN & ROOM FINISH SCHEDULE FOR DETAILS)

AutoCAD SHX Text A-103

AutoCAD SHX Text

AutoCAD SHX Text A-103

AutoCAD SHX Text

AutoCAD SHX Text 4'

AutoCAD SHX Text STAINLESS STEEL SINK, GARBAGE DISPOSAL, AND NEW FAUCET. PROVIDE FAUCET HOLES, SEE PLUMBING DRAWINGS. PROVIDE AND INSTALL HOOD. REFERENCE MECHANICAL DRAWINGS FOR ADDITIONAL VENTING AND SUPPRESSION REQUIREMENTS. REFERENCE ELECTRICAL DRAWINGS FOR ANSUL SYSTEM & SHUT DOWN. MODIFY CEILING SYSTEM AS NEEDED, SEE ROOM & MATERIAL FINISH SCHEDULE. ELECTRICAL RANGES & REFRIGERATOR PROVIDED BY GOVERNMENT.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 4 1/4" x 12 3/4" TILE W/ RUNNING BOND INSTALLATION. PROVIDE LATICRETE SPECTRALLOCK PRO GROUT PREMIUM IN WHITE. SEE ROOM & MATERIAL SCHEDULE.

AutoCAD SHX Text

WHITE CAULKING ALONG BACKSPLASH AND COUNTERTOP JOINT.

AutoCAD SHX Text

1" THICK SOLID SURFACE QUARTZ FOR ALL COUNTERTOPS.

AutoCAD SHX Text

12" DEEP WOOD CABINETS, SEE ROOM & MATERIAL FINISH SCHEDULE.

AutoCAD SHX Text

24" DEEP WOOD BASE, SEE ROOM & MATERIAL FINISH SCHEDULE.

AutoCAD SHX Text PROVIDE CEILING TILE WITH ARMSTRONG KITCHEN ZONE 672 OR EQUAL. PROVIDE PRELUDE " 1516" SUSPENSION SYSTEM OR EQUAL, AS NECESSARY.

AutoCAD SHX Text

AutoCAD SHX Text NO WORK ON FLOOR, LEAVE EXISTING. CONSTRUCT NEW INTERIOR WALL WITH 24 GAUGE 6" METAL STUDS, 16" ON CENTER, R-19 SOUND ATTENUATION BLANKETS IN THE WALL CAVITY AND " 58" TYPE X DRYWALL EACH SIDE, TAPE, TEXTURE AND PAINT DRYWALL. SEE ROOM & MATERIAL SCHEDULE.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PAINT WALLS

AutoCAD SHX Text

AutoCAD SHX Text

FIX CEILING SYSTEM WITH NEW FINISHES.

AutoCAD SHX Text

AutoCAD SHX Text

NEW DRINKING FOUNTAIN WITH BOTTLE FILLER

AutoCAD SHX Text 2'

AutoCAD SHX Text 2'

AutoCAD SHX Text 11B-10118-6P

FLOOR BASE: JOHNSONITE - #47 BROWN CEILING PAINT COLOR: SW 7006 EXTRA WHITE (IF HARD CEILING, PAINT IS REQUIRED) ACOUSTICAL CEILING TILE: ARMSTRONG - KITCHEN ZONE 672 (IF ACT, NEEDS TO BE REPLACED) CEILING GRID: PRELUDE 15/16" SUSPENSION SYSTEM (AS NEEDED). WALL PAINT COLOR: SW 7516 KESTREL WHITE DOOR FRAME: SW 7513 SANDERLING FLOOR: SW 7513 SANDERLING CABINET SPECIFICATIONS: BIRCH WOOD WITH SW 3105 K PLUM MAHOGANY FINISH ALL-PLYWOOD CARB COMPLIANT BOX CONSTRUCTION, SOLID 1/2 IN. THICK ENGINEERED WOOD FOR BACK AND SIDES SOLID BIRCH DOOR FRAME WITH STURDY 1/2 IN. THICK BIRCH CENTER PANEL SHAKER DOORS WITH 3 IN. WIDE FRAMES AND FLAT RECESSED CENTER PANELS 3/4 IN. THICK PLYWOOD ADJUSTABLE SHELVES WITH CLEAR HIGH-STRENGTH LOCKING SHELF SUPPORTS FOR ADDED STRENGTH 2 FULL DEPTH ADJUSTABLE SHELVES (WALL CABINETS) 1 - ½ DEPTH ADJUSTABLE SHELVES (BASE CABINETS) ALL WALL CABINETS MUST BE 12” ALL BASE CABINETS MUST BE 24” ALL BASE CABINETS WILL HAVE A DRAWER WITH FULL ACCESS HIDDEN GLIDES SYSTEM PROVIDE 2 - 4 DRAWER BASE CABINET CONCEALED HIGH QUALITY STEEL DOOR HINGES ARE 6-WAY ADJUSTABLE TOE KICK TO MATCH FINISH 2 DOOR BUMPERS PER DOOR/DRAWER PROVIDE 3” SATIN NICKEL BAR IN ALL WALL CABINETS, BASE CABINETS & DRAWERS SATIN NICKEL BAR IN ALL WALL CABINETS, BASE CABINETS & DRAWERS COUNTERTOP: 1" THICK SOLID DUPONT ZODIAQ QUARTS SURFACES - MINERAL PEARL BACKSPLASH TILE: 4 ¼” X 12 " ARTIC WHITE (0190 DALTILE - MODERN DIMENSIONS SEMI GLOSS), RUNNING BOND X 12 " ARTIC WHITE (0190 DALTILE - MODERN DIMENSIONS SEMI GLOSS), RUNNING BOND 34" ARTIC WHITE (0190 DALTILE - MODERN DIMENSIONS SEMI GLOSS), RUNNING BOND INSTALLATION. GROUT: LATICRETE SPECTRALLOCK PRO GROUT PREMIUM IN WHITE. CAULKING @ COUNTERTOP & TILE CONNECTION: SILICONE WATERPROOF. SINK: TOP MOUNT KOHLER VERSE, K-20060-1-NA, SINGLE FAUCET HOLE, 18 GAGE. FAUCET: COMMERCIAL SINGLE HANDLE KITCHEN FAUCET, DELTA #101LF-HDF CHROME. WATER COOLER: BOTTLE FILLING STATION WITH SINGLE ADA, ELKEY EZ H O. WASTE DISPOSER: TURBOGRIND MAX 1HP CONTINUES FEED GARBAGE DISPOSAL WITH POWER COLD, UL 430 MODEL#10-US-GB1000SL 2800 RPM, 120V.

W

FO

R T

B

LI

SS

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

TV ROOM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1'-8"

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text 2'-10"

AutoCAD SHX Text 7'-6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 4'-8"

AutoCAD SHX Text 2'-10"

AutoCAD SHX Text

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

NEW WORK PLAN - 2ND FLOOR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-104

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text 04/23/2026

AutoCAD SHX Text L.L.

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text L.L.

AutoCAD SHX Text

AutoCAD SHX Text

NEW WORK PLAN - 2ND FLOOR

AutoCAD SHX Text

SCALE: 1/4"=1'-0"

AutoCAD SHX Text

BUILDING 2479 KITCHENETTE INSTALLATION

AutoCAD SHX Text

NEW WORK KEYED NOTES

AutoCAD SHX Text

ROOM FINISH SCHEDULE AND PLUMBING FIXTURES (OR EQUAL)

AutoCAD SHX Text

NEW WORK GENERAL NOTES

AutoCAD SHX Text

AutoCAD SHX Text

CABINET ELEVATION

AutoCAD SHX Text

SCALE: 3/8"=1'-0"

AutoCAD SHX Text

(SEE FLOOR PLAN & ROOM FINISH SCHEDULE FOR DETAILS)

AutoCAD SHX Text

AutoCAD SHX Text

CABINET ELEVATION

AutoCAD SHX Text

SCALE: 3/8"=1'-0"

AutoCAD SHX Text

(SEE FLOOR PLAN & ROOM FINISH SCHEDULE FOR DETAILS)

AutoCAD SHX Text 3'

AutoCAD SHX Text 3'

AutoCAD SHX Text 2'-8"

AutoCAD SHX Text 2'-9"

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text 2'-9"

AutoCAD SHX Text A-104

AutoCAD SHX Text

AutoCAD SHX Text A-104

AutoCAD SHX Text

AutoCAD SHX Text STAINLESS STEEL SINK, GARBAGE DISPOSAL, AND NEW FAUCET. PROVIDE FAUCET HOLES, SEE PLUMBING DRAWINGS. PROVIDE AND INSTALL HOOD. REFERENCE MECHANICAL DRAWINGS FOR ADDITIONAL VENTING AND SUPPRESSION REQUIREMENTS. REFERENCE ELECTRICAL DRAWINGS FOR ANSUL SYSTEM & SHUT DOWN. MODIFY CEILING SYSTEM AS NEEDED, SEE ROOM & MATERIAL FINISH SCHEDULE. ELECTRICAL RANGES & REFRIGERATOR PROVIDED BY GOVERNMENT.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 4 1/4" x 12 3/4" TILE W/ RUNNING BOND INSTALLATION. PROVIDE LATICRETE SPECTRALLOCK PRO GROUT PREMIUM IN WHITE. SEE ROOM & MATERIAL SCHEDULE.

AutoCAD SHX Text

WHITE CAULKING ALONG BACKSPLASH AND COUNTERTOP JOINT.

AutoCAD SHX Text

1" THICK SOLID SURFACE QUARTZ FOR ALL COUNTERTOPS.

AutoCAD SHX Text

12" DEEP WOOD CABINETS, SEE ROOM & MATERIAL FINISH SCHEDULE.

AutoCAD SHX Text

24" DEEP WOOD BASE, SEE ROOM & MATERIAL FINISH SCHEDULE.

AutoCAD SHX Text PROVIDE CEILING TILE WITH ARMSTRONG KITCHEN ZONE 672 OR EQUAL. PROVIDE PRELUDE " 1516" SUSPENSION SYSTEM OR EQUAL, AS NECESSARY.

AutoCAD SHX Text

AutoCAD SHX Text NO WORK ON FLOOR, LEAVE EXISTING. CONSTRUCT NEW INTERIOR WALL WITH 24 GAUGE 6" METAL STUDS, 16" ON CENTER, R-19 SOUND ATTENUATION BLANKETS IN THE WALL CAVITY AND " 58" TYPE X DRYWALL EACH SIDE, TAPE, TEXTURE AND PAINT DRYWALL. SEE ROOM & MATERIAL SCHEDULE.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PAINT WALLS

AutoCAD SHX Text

AutoCAD SHX Text

FIX CEILING SYSTEM WITH NEW FINISHES.

AutoCAD SHX Text

AutoCAD SHX Text

NEW DRINKING FOUNTAIN WITH BOTTLE FILLER

AutoCAD SHX Text

1. UNLESS NOTED OTHERWISE, ALL NEW INTERIOR SURFACES SHALL BE PAINTED. REFERENCE THE ROOM SCHEDULE FOR FINISHES. WALLS, DOORS, ALL DOOR FRAMES. 2. PATCH AND REPAIR ALL AREAS DAMAGED BY DEMOLITION WORK PRIOR TO APPLYING NEW CONSTRUCTION FINISHES. PATCH HOLES IN WOOD WITH A TWO PART EPOXY WOOD FILLER AND PREPARE SURFACE FOR PAINT. 3. EXISTING EXTERIOR FINISHES SHALL REMAIN, PROTECT FROM DAMAGE DURING DEMOLITION AND NEW CONSTRUCTION ACTIVITIES. 4. NEW SYSTEMS FURNITURE AND MODULAR ARCHITECTURAL NEW SYSTEMS FURNITURE AND MODULAR ARCHITECTURAL WALL ARE NOT A PART OF THIS CONTRACT. ANY FURNITURE AND/OR WALL INDICATED IN THE FLOOR PLANS ARE FOR CONVENIENCE OF THE CONTRACTOR TO IDENTIFY FURNITURE LOCATIONS. 5. REFERENCE ALL MEP DRAWINGS. REFERENCE ALL MEP DRAWINGS. 6. INSTALL UNDER-CABINET LIGHTING UNDERNEATH ALL INSTALL UNDER-CABINET LIGHTING UNDERNEATH ALL WALL CABINETS. REFERENCE ELECTRICAL DRAWINGS. 7. SEE ROOM & MATERIAL FINISH SCHEDULE. SEE ROOM & MATERIAL FINISH SCHEDULE. 8. NOTE NOT ALL KEYED NOTES ARE USED ON THIS SHEET.NOTE NOT ALL KEYED NOTES ARE USED ON THIS SHEET.

AutoCAD SHX Text 11B-10118-6P

FLOOR BASE: JOHNSONITE - #47 BROWN CEILING PAINT COLOR: SW 7006 EXTRA WHITE (IF HARD CEILING, PAINT IS REQUIRED) ACOUSTICAL CEILING TILE: ARMSTRONG - KITCHEN ZONE 672 (IF ACT, NEEDS TO BE REPLACED) CEILING GRID: PRELUDE 15/16" SUSPENSION SYSTEM (AS NEEDED). WALL PAINT COLOR: SW 7516 KESTREL WHITE DOOR FRAME: SW 7513 SANDERLING FLOOR: SW 7513 SANDERLING CABINET SPECIFICATIONS: BIRCH WOOD WITH SW 3105 K PLUM MAHOGANY FINISH ALL-PLYWOOD CARB COMPLIANT BOX CONSTRUCTION, SOLID 1/2 IN. THICK ENGINEERED WOOD FOR BACK AND SIDES SOLID BIRCH DOOR FRAME WITH STURDY 1/2 IN. THICK BIRCH CENTER PANEL SHAKER DOORS WITH 3 IN. WIDE FRAMES AND FLAT RECESSED CENTER PANELS 3/4 IN. THICK PLYWOOD ADJUSTABLE SHELVES WITH CLEAR HIGH-STRENGTH LOCKING SHELF SUPPORTS FOR ADDED STRENGTH 2 FULL DEPTH ADJUSTABLE SHELVES (WALL CABINETS) 1 - ½ DEPTH ADJUSTABLE SHELVES (BASE CABINETS) ALL WALL CABINETS MUST BE 12” ALL BASE CABINETS MUST BE 24” ALL BASE CABINETS WILL HAVE A DRAWER WITH FULL ACCESS HIDDEN GLIDES SYSTEM PROVIDE 2 - 4 DRAWER BASE CABINET CONCEALED HIGH QUALITY STEEL DOOR HINGES ARE 6-WAY ADJUSTABLE TOE KICK TO MATCH FINISH 2 DOOR BUMPERS PER DOOR/DRAWER PROVIDE 3” SATIN NICKEL BAR IN ALL WALL CABINETS, BASE CABINETS & DRAWERS SATIN NICKEL BAR IN ALL WALL CABINETS, BASE CABINETS & DRAWERS COUNTERTOP: 1" THICK SOLID DUPONT ZODIAQ QUARTS SURFACES - MINERAL PEARL BACKSPLASH TILE: 4 ¼” X 12 " ARTIC WHITE (0190 DALTILE - MODERN DIMENSIONS SEMI GLOSS), RUNNING BOND X 12 " ARTIC WHITE (0190 DALTILE - MODERN DIMENSIONS SEMI GLOSS), RUNNING BOND 34" ARTIC WHITE (0190 DALTILE - MODERN DIMENSIONS SEMI GLOSS), RUNNING BOND INSTALLATION. GROUT: LATICRETE SPECTRALLOCK PRO GROUT PREMIUM IN WHITE. CAULKING @ COUNTERTOP & TILE CONNECTION: SILICONE WATERPROOF. SINK: TOP MOUNT KOHLER VERSE, K-20060-1-NA, SINGLE FAUCET HOLE, 18 GAGE. FAUCET: COMMERCIAL SINGLE HANDLE KITCHEN FAUCET, DELTA #101LF-HDF CHROME. WATER COOLER: BOTTLE FILLING STATION WITH SINGLE ADA, ELKEY EZ H O. WASTE DISPOSER: TURBOGRIND MAX 1HP CONTINUES FEED GARBAGE DISPOSAL WITH POWER COLD, UL 430 MODEL#10-US-GB1000SL 2800 RPM, 120V.

W

FO

R T

B

LI

SS

KITCHEN HOOD SCHEDULE

AutoCAD SHX Text

DAY ROOM

AutoCAD SHX Text

AutoCAD SHX Text T.V.

AutoCAD SHX Text

AutoCAD SHX Text

GAME ROOM

AutoCAD SHX Text

AutoCAD SHX Text

MAIL

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

COMMO.

AutoCAD SHX Text

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

MECHANICAL WORK PLAN - 1ST FLOOR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text M-100

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text 04/23/2026

AutoCAD SHX Text L.L.

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text L.L.

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL WORK PLAN - 1ST FLOOR

AutoCAD SHX Text

SCALE: 1/4"=1'-0"

AutoCAD SHX Text

BUILDING 2479 KITCHENETTE INSTALLATION

AutoCAD SHX Text

NEW WORK KEYED NOTES

AutoCAD SHX Text

DEMOLITION GENERAL NOTES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

1. CONTRACTOR SHALL FIELD VERIFY EXTENT OF ALL DEMOLITION AND REPORT ALL DISCREPANCIES TO THE GOVERNMENT REPRESENTATIVE PRIOR TO START OF WORK. 2. CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL CODES, ORDINANCES, AND REGULATIONS APPLICABLE AT PROJECT LOCATION, CONTRACTOR SHALL FILE AND SECURE ALL APPLICABLE PERMITS, APPROVALS, ETC. 3. ALL EXISTING HVAC EQUIPMENT AND MATERIALS FIXTURES TO BE REMOVED SHALL BE DISPOSED OF PROPERLY AT AN APPROVED OFF SITE LOCATION. 4. CONTRACTOR SHALL TAKE PRECAUTIONS AS NECESSARY TO PROTECT FROM DAMAGING UNDERGROUND WORK, UTILITY LINES, WALKS, LANDSCAPING, ETC. 5. ITEMS INDICATED TO REMAIN SHALL REMAIN IN THE ORIGINAL STATE AS IT WAS PRIOR TO THE START OF CONSTRUCTION. IF ALTERED OR DAMAGED DURING CONSTRUCTION, CONTRACTOR SHALL REPAIR, RESTORE, AND/OR REPLACE ITEMS AS REQUIRED TO RETURN ITEM TO PRE-CONSTRUCTION CONDITIONS. 6. ALL PENETRATIONS REQUIRED FOR MECHANICAL WORK SHALL BE COORDINATED WITH OTHER DISCIPLINES TO ENSURE NO DISCREPANCIES HAVE BEEN OVERLOOKED OR NO DAMAGE OCCURS WHILE PERFORMING THIS WORK. ALL PENETRATIONS SHALL BE REPAIRED AND PATCHED WITH A COMPLETE WATER TIGHT SYSTEM TO MATCH EXISTING WALL OR ROOF. CONTRACTOR SHALL ENSURE NO LEAKS REMAIN IN ANY PENETRATION THROUGH WALL OR ROOF. 7. FIELD VERIFY ALL LOCATIONS OF EQUIPMENT AND MATERIALS FOR ALL HEATING, COOLING AND PLUMBING WORK. VERIFY WITH GOVERNMENT REPRESENTATIVE AND HISTORICAL BRANCH REPRESENTATIVE PRIOR TO MAKING ANY PENETRATIONS THROUGH THE ROOF OR WALLS OF THE BUILDING.

AutoCAD SHX Text PROVIDE NEW STAINLESS STEEL DOUBLE BOWL SINK WITH SPRAYER FOR KITCHEN AREA AS SPECIFIED ON ARCHITECTURAL SHEETS. PROVIDE NEW FAUCET SUPPLY LINES AND CONNECT HOT AND COLD WATER TO EXISTING VALVES UNDERNEATH CABINET. CONNECT SANITARY SEWER TO EXISTING SANITARY SEWER UNDER CABINETS. ENSURE SINK FUNCTIONS PROPER. PROVIDE NEW KITCHEN HOOD AS SPECIFIED IN THE DRAWINGS AND SCHEDULES. DENOTED AS RH-1. KITCHEN HOOD EXHAUST SHALL BE DUCTED FROM THE EXHAUST OF THE HOOD THROUGH CABINETS TO THE VENT ON THE EXTERIOR WALL AS SHOWN IN THE DRAWINGS. DUCTWORK SHALL BE OF INDUSTRIAL GRADE. ENSURE RANGE HOOD FUNCTIONS PROPER. PROVIDE NEW EIGHT INCH ROUND DUCT CONNECTED TO RANGE HOOD THROUGH WALL TO NEW WALL VENT FOR EXTERIOR EXHAUST AS SPECIFIED IN THE DRAWINGS. WALL VENT SHALL MEET SIZE AND AIRFLOW REQUIREMENTS OF THE KITCHEN HOOD AND ACCOMPANYING DUCTWORK. FINISH THE WALL VENT TO MATCH THE EXTERIOR WAUL OF THE BUILDING OR AS SPECIFIED BY THE GOVERNMENT REPRESENTATIVE. PROVIDE NEW ANSUL FIRE SUPPRESSION SYSTEM WITH KITCHEN HOOD ANSUL SYSTEM SHALL MEET ALL APPLICABLE CODES AND REGULATIONS AND SHALL BE CONNECTED TO THE FIRE ALARM SYSTEM OF THE BUILDING. ALL FIRE ALARM, FIRE SUPPRESSION, AND MASS NOTIFICATION MODIFICATIONS AND ADDITIONS MUST BE APPROVED BY THE FORT BLISS FIRE DEPARTMENT(FBFD) PRIOR TO START OF INSTALLATION. FBFD MUST ALSO TEST AND CERTIFY ALL AFFECTED SYSTEMS PRIOR TO PROJECT COMPLETION.

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO STARTING ON THE NEW WORK PORTION OF THE PROJECT. CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINES TO ENSURE PROPER INSTALLATION. ALL DISCREPANCIES SHALL BE REPORTED TO THE GOVERNMENT REPRESENTATIVE. 2. CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL CODES, ORDINANCES, AND REGULATIONS APPLICABLE AT PROJECT LOCATION, CONTRACTOR SHALL FILE AND SECURE ALL APPLICABLE PERMITS, APPROVALS, ETC.

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

1. SHALL HAVE DEDICATED GFCI OUTLET

AutoCAD SHX Text

2. EXHAUST DUCT IS 8" IN DIAMETER

AutoCAD SHX Text

3. INCLUDE GRAVITY DAMPER

AutoCAD SHX Text

4. PROVIDE PERMATECTOR COATING

AutoCAD SHX Text

NOTES

AutoCAD SHX Text

SONES MIN/MAX

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

PHASE

AutoCAD SHX Text

VOLTS

AutoCAD SHX Text

AMPS

AutoCAD SHX Text

RPM

AutoCAD SHX Text

SP

AutoCAD SHX Text

CFM MIN/ MAX

AutoCAD SHX Text

MODEL

AutoCAD SHX Text

TAG

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

UNDER CABINET

AutoCAD SHX Text

PS-13

AutoCAD SHX Text 385/900

AutoCAD SHX Text

AutoCAD SHX Text 0.7

AutoCAD SHX Text

AutoCAD SHX Text 1,2,3,4

AutoCAD SHX Text

RH-1

AutoCAD SHX Text 1.5/7.5

AutoCAD SHX Text 0.35

AutoCAD SHX Text

AutoCAD SHX Text

CYCLES

AutoCAD SHX Text

AutoCAD SHX Text

MANUFACTURER OR EQUAL

AutoCAD SHX Text

CAVALIERE

W

FO

R T

B

LI

SS

KITCHEN HOOD SCHEDULE

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

TV ROOM

AutoCAD SHX Text

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

MECHANICAL WORK PLAN - 2ND FLOOR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text M-101

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text 04/23/2026

AutoCAD SHX Text L.L.

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text L.L.

AutoCAD SHX Text

BUILDING 2479 KITCHENETTE INSTALLATION

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL WORK PLAN - 2ND FLOOR

AutoCAD SHX Text

SCALE: 1/4"=1'-0"

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

1. SHALL HAVE DEDICATED GFCI OUTLET

AutoCAD SHX Text

2. EXHAUST DUCT IS 8" IN DIAMETER

AutoCAD SHX Text

3. INCLUDE GRAVITY DAMPER

AutoCAD SHX Text

4. PROVIDE PERMATECTOR COATING

AutoCAD SHX Text

NOTES

AutoCAD SHX Text

SONES MIN/MAX

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

PHASE

AutoCAD SHX Text

VOLTS

AutoCAD SHX Text

AMPS

AutoCAD SHX Text

RPM

AutoCAD SHX Text

SP

AutoCAD SHX Text

CFM MIN/ MAX

AutoCAD SHX Text

MODEL

AutoCAD SHX Text

TAG

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

UNDER CABINET

AutoCAD SHX Text

PS-13

AutoCAD SHX Text 385/900

AutoCAD SHX Text

AutoCAD SHX Text 0.7

AutoCAD SHX Text

AutoCAD SHX Text 1,2,3,4

AutoCAD SHX Text

RH-1

AutoCAD SHX Text 1.5/7.5

AutoCAD SHX Text 0.35

AutoCAD SHX Text

AutoCAD SHX Text

CYCLES

AutoCAD SHX Text

AutoCAD SHX Text

MANUFACTURER OR EQUAL

AutoCAD SHX Text

CAVALIERE

AutoCAD SHX Text

NEW WORK KEYED NOTES

AutoCAD SHX Text

DEMOLITION GENERAL NOTES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

1. CONTRACTOR SHALL FIELD VERIFY EXTENT OF ALL DEMOLITION AND REPORT ALL DISCREPANCIES TO THE GOVERNMENT REPRESENTATIVE PRIOR TO START OF WORK. 2. CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL CODES, ORDINANCES, AND REGULATIONS APPLICABLE AT PROJECT LOCATION, CONTRACTOR SHALL FILE AND SECURE ALL APPLICABLE PERMITS, APPROVALS, ETC. 3. ALL EXISTING HVAC EQUIPMENT AND MATERIALS FIXTURES TO BE REMOVED SHALL BE DISPOSED OF PROPERLY AT AN APPROVED OFF SITE LOCATION. 4. CONTRACTOR SHALL TAKE PRECAUTIONS AS NECESSARY TO PROTECT FROM DAMAGING UNDERGROUND WORK, UTILITY LINES, WALKS, LANDSCAPING, ETC. 5. ITEMS INDICATED TO REMAIN SHALL REMAIN IN THE ORIGINAL STATE AS IT WAS PRIOR TO THE START OF CONSTRUCTION. IF ALTERED OR DAMAGED DURING CONSTRUCTION, CONTRACTOR SHALL REPAIR, RESTORE, AND/OR REPLACE ITEMS AS REQUIRED TO RETURN ITEM TO PRE-CONSTRUCTION CONDITIONS. 6. ALL PENETRATIONS REQUIRED FOR MECHANICAL WORK SHALL BE COORDINATED WITH OTHER DISCIPLINES TO ENSURE NO DISCREPANCIES HAVE BEEN OVERLOOKED OR NO DAMAGE OCCURS WHILE PERFORMING THIS WORK. ALL PENETRATIONS SHALL BE REPAIRED AND PATCHED WITH A COMPLETE WATER TIGHT SYSTEM TO MATCH EXISTING WALL OR ROOF. CONTRACTOR SHALL ENSURE NO LEAKS REMAIN IN ANY PENETRATION THROUGH WALL OR ROOF. 7. FIELD VERIFY ALL LOCATIONS OF EQUIPMENT AND MATERIALS FOR ALL HEATING, COOLING AND PLUMBING WORK. VERIFY WITH GOVERNMENT REPRESENTATIVE AND HISTORICAL BRANCH REPRESENTATIVE PRIOR TO MAKING ANY PENETRATIONS THROUGH THE ROOF OR WALLS OF THE BUILDING.

AutoCAD SHX Text PROVIDE NEW STAINLESS STEEL DOUBLE BOWL SINK WITH SPRAYER FOR KITCHEN AREA AS SPECIFIED ON ARCHITECTURAL SHEETS. PROVIDE NEW FAUCET SUPPLY LINES AND CONNECT HOT AND COLD WATER TO EXISTING VALVES UNDERNEATH CABINET. CONNECT SANITARY SEWER TO EXISTING SANITARY SEWER UNDER CABINETS. ENSURE SINK FUNCTIONS PROPER. PROVIDE NEW KITCHEN HOOD AS SPECIFIED IN THE DRAWINGS AND SCHEDULES. DENOTED AS RH-1. KITCHEN HOOD EXHAUST SHALL BE DUCTED FROM THE EXHAUST OF THE HOOD THROUGH CABINETS TO THE VENT ON THE EXTERIOR WALL AS SHOWN IN THE DRAWINGS. DUCTWORK SHALL BE OF INDUSTRIAL GRADE. ENSURE RANGE HOOD FUNCTIONS PROPER. PROVIDE NEW EIGHT INCH ROUND DUCT CONNECTED TO RANGE HOOD THROUGH WALL TO NEW WALL VENT FOR EXTERIOR EXHAUST AS SPECIFIED IN THE DRAWINGS. WALL VENT SHALL MEET SIZE AND AIRFLOW REQUIREMENTS OF THE KITCHEN HOOD AND ACCOMPANYING DUCTWORK. FINISH THE WALL VENT TO MATCH THE EXTERIOR WAUL OF THE BUILDING OR AS SPECIFIED BY THE GOVERNMENT REPRESENTATIVE. PROVIDE NEW ANSUL FIRE SUPPRESSION SYSTEM WITH KITCHEN HOOD ANSUL SYSTEM SHALL MEET ALL APPLICABLE CODES AND REGULATIONS AND SHALL BE CONNECTED TO THE FIRE ALARM SYSTEM OF THE BUILDING. ALL FIRE ALARM, FIRE SUPPRESSION, AND MASS NOTIFICATION MODIFICATIONS AND ADDITIONS MUST BE APPROVED BY THE FORT BLISS FIRE DEPARTMENT(FBFD) PRIOR TO START OF INSTALLATION. FBFD MUST ALSO TEST AND CERTIFY ALL AFFECTED SYSTEMS PRIOR TO PROJECT COMPLETION.

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO STARTING ON THE NEW WORK PORTION OF THE PROJECT. CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINES TO ENSURE PROPER INSTALLATION. ALL DISCREPANCIES SHALL BE REPORTED TO THE GOVERNMENT REPRESENTATIVE. 2. CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL CODES, ORDINANCES, AND REGULATIONS APPLICABLE AT PROJECT LOCATION, CONTRACTOR SHALL FILE AND SECURE ALL APPLICABLE PERMITS, APPROVALS, ETC.

W

FO

R T

B

LI

SS

AutoCAD SHX Text

DAY ROOM

AutoCAD SHX Text

AutoCAD SHX Text

GAME ROOM

AutoCAD SHX Text

AutoCAD SHX Text

MAIL

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

CW

AutoCAD SHX Text

HW

AutoCAD SHX Text

CW

AutoCAD SHX Text

HW

AutoCAD SHX Text

ARMS VAULT

AutoCAD SHX Text B-5

AutoCAD SHX Text

ISSUE

AutoCAD SHX Text B-4

AutoCAD SHX Text

UNIT STORAGE

AutoCAD SHX Text B-3

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

PLUMBING WORK PLAN - 1ST FLOOR & BASEMENT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text P-100

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text 04/23/2026

AutoCAD SHX Text L.L.

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text L.L.

AutoCAD SHX Text

AutoCAD SHX Text

PLUMBING WORK PLAN - 1ST FLOOR

AutoCAD SHX Text

SCALE: 1/4"=1'-0"

AutoCAD SHX Text

BUILDING 2479 KITCHENETTE INSTALLATION

AutoCAD SHX Text

DEMOLITION GENERAL NOTES

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

1. CONTRACTOR SHALL FIELD VERIFY EXTENT OF ALL DEMOLITION AND REPORT ALL DISCREPANCIES TO THE GOVERNMENT REPRESENTATIVE PRIOR TO START OF WORK. 2. CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL CODES, ORDINANCES, AND REGULATIONS APPLICABLE AT PROJECT LOCATION, CONTRACTOR SHALL FILE AND SECURE ALL APPLICABLE PERMITS, APPROVALS, ETC. 3. CONTRACTOR SHALL TAKE PRECAUTIONS AS NECESSARY TO PROTECT FROM DAMAGING UNDERGROUND WORK, UTILITY LINES, WALKS, LANDSCAPING, ETC. 4. ITEMS INDICATED TO REMAIN SHALL REMAIN IN THE ORIGINAL STATE AS IT WAS PRIOR TO THE START OF CONSTRUCTION. IF ALTERED OR DAMAGED DURING CONSTRUCTION, CONTRACTOR SHALL REPAIR, RESTORE, AND/OR REPLACE ITEMS AS REQUIRED TO RETURN ITEM TO PRE-CONSTRUCTION CONDITIONS. 5. ALL PENETRATIONS REQUIRED FOR MECHANICAL WORK SHALL BE COORDINATED WITH OTHER DISCIPLINES TO ENSURE NO DISCREPANCIES HAVE BEEN OVERLOOKED OR NO DAMAGE OCCURS WHILE PERFORMING THIS WORK. ALL PENETRATIONS SHALL BE REPAIRED AND PATCHED WITH A COMPLETE WATER TIGHT SYSTEM TO MATCH EXISTING WALL OR ROOF. CONTRACTOR SHALL ENSURE NO LEAKS REMAIN IN ANY PENETRATION THROUGH WALL OR ROOF. 6. FIELD VERIFY ALL LOCATIONS OF EQUIPMENT AND MATERIALS FOR ALL HEATING, COOLING AND PLUMBING WORK. VERIFY WITH GOVERNMENT REPRESENTATIVE AND HISTORICAL BRANCH REPRESENTATIVE PRIOR TO MAKING ANY PENETRATIONS THROUGH THE ROOF OR WALLS OF THE BUILDING.

AutoCAD SHX Text

1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO STARTING ON THE NEW WORK PORTION OF THE PROJECT. CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINES TO ENSURE PROPER INSTALLATION. ALL DISCREPANCIES SHALL BE REPORTED TO THE GOVERNMENT REPRESENTATIVE. 2. CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL CODES, ORDINANCES, AND REGULATIONS APPLICABLE AT PROJECT LOCATION, CONTRACTOR SHALL FILE AND SECURE ALL APPLICABLE PERMITS, APPROVALS, ETC. 3. CONTRACTOR SHALL PROVIDE ALL PLUMBING FIXTURES SHOWN IN THE DRAWINGS AS SPECIFIED ON ARCHITECTURAL SHEETS. 4. CONTRACTOR SHALL PROVIDE ALL CONNECTIONS, SUPPORTS, PEE TRAPS, AND ALL OTHER MATERIALS AND EQUIPMENT TO MEET ALL APPLICABLE COEDS AND REGULATIONS AND TO ENSURE PROPER OPERATIONS OF ALL PLUMBING FIXTURES IN THE BUILDING. 5. CONTRACTOR SHALL PROVIDE CLEAN OUTS OF APPROPRIATE SIZE FOR ALL FIXTURES AS PER ALL APPLICABLE CODES AND REGULATIONS.

AutoCAD SHX Text

NEW WORK KEYED NOTES

AutoCAD SHX Text

AutoCAD SHX Text PROVIDE NEW STAINLESS STEEL DOUBLE BOWL SINK WITH SPRAYER FOR KITCHEN AREA AS SPECIFIED ON ARCHITECTURAL SHEETS. PROVIDE NEW FAUCET SUPPLY LINES AND CONNECT HOT AND COLD WATER TO EXISTING VALVES UNDERNEATH CABINET. CONNECT SANITARY SEWER TO EXISTING SANITARY SEWER UNDER CABINETS. ENSURE SINK FUNCTIONS PROPER

AutoCAD SHX Text

AutoCAD SHX Text

PLUMBING WORK PLAN - BASEMENT

AutoCAD SHX Text

SCALE: 1/4"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text PROVIDE AND INSTALL WATER FOUNTAIN WITH BOTTLE FILLING STATION WITH SINGLE ADA COOLER NON-FILTERED.

AutoCAD SHX Text

AutoCAD SHX Text

PERFORM DIAGNOSTIC CORE DRILLING TO LOCATE SEWER LINE.

AutoCAD SHX Text

AutoCAD SHX Text

INSTALL A NEW PVC SCHEDULE 40 AND CONNECT TO THE EXISTING PIPE.

AutoCAD SHX Text

EXISTING 4" C.I. DWV

AutoCAD SHX Text

TIE INTO EXISTING DWV LINE

AutoCAD SHX Text

1 " DRAIN FROM 12" DRAIN FROM 1ST FLOOR

AutoCAD SHX Text CONNECT " HOT WATER 12" HOT WATER & " COLD WATER TO 12" COLD WATER TO EXISTING LINES ABOVE CEILING.

AutoCAD SHX Text

CONNECT COLD WATER TO EXISTING LINE ABOVE CEILING.

AutoCAD SHX Text

CONNECT 1 " VENT TO 12" VENT TO EXISTING VENT ABOVE CEILING.

AutoCAD SHX Text

AutoCAD SHX Text

SECTION/ELEVATION

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

2ND FLOOR SPACE

AutoCAD SHX Text

NEW VENT LINE THROUGH CEILING SPACE

AutoCAD SHX Text

EXISTING 1ST FLOOR CEILING

AutoCAD SHX Text

EXISTING HOT & COLD DOMESTIC WATER

AutoCAD SHX Text

NEW " DIA. WATER 12" DIA. WATER LINES

AutoCAD SHX Text

NEW PARTITION WALL

AutoCAD SHX Text

1 " DIA. VENT LINE12" DIA. VENT LINE

AutoCAD SHX Text

NEW CABINET W/SINK

AutoCAD SHX Text

PROVIDE PEE TRAP

AutoCAD SHX Text

1ST FLOOR SPACE

AutoCAD SHX Text

EXISTING BASEMENT CEILING

AutoCAD SHX Text

CORE DRILL FOR PIPE PENETRATION

AutoCAD SHX Text

EXISTING 4" DMV C.I. PIPE

AutoCAD SHX Text

1 " DIA. DRAIN LINE12" DIA. DRAIN LINE

AutoCAD SHX Text

BASEMENT

AutoCAD SHX Text P-100

AutoCAD SHX Text

AutoCAD SHX Text

1 " DRAIN FROM 12" DRAIN FROM 1ST FLOOR

W

FO

R T

B

LI

SS

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

DORM

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

TV ROOM

AutoCAD SHX Text

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

PLUMBING WORK PLAN - 2ND FLOOR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text P-101

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text 04/23/2026

AutoCAD SHX Text L.L.

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text L.L.

AutoCAD SHX Text

BUILDING 2479 KITCHENETTE INSTALLATION

AutoCAD SHX Text

DEMOLITION GENERAL NOTES

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

1. CONTRACTOR SHALL FIELD VERIFY EXTENT OF ALL DEMOLITION AND REPORT ALL DISCREPANCIES TO THE GOVERNMENT REPRESENTATIVE PRIOR TO START OF WORK. 2. CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL CODES, ORDINANCES, AND REGULATIONS APPLICABLE AT PROJECT LOCATION, CONTRACTOR SHALL FILE AND SECURE ALL APPLICABLE PERMITS, APPROVALS, ETC. 3. CONTRACTOR SHALL TAKE PRECAUTIONS AS NECESSARY TO PROTECT FROM DAMAGING UNDERGROUND WORK, UTILITY LINES, WALKS, LANDSCAPING, ETC. 4. ITEMS INDICATED TO REMAIN SHALL REMAIN IN THE ORIGINAL STATE AS IT WAS PRIOR TO THE START OF CONSTRUCTION. IF ALTERED OR DAMAGED DURING CONSTRUCTION, CONTRACTOR SHALL REPAIR, RESTORE, AND/OR REPLACE ITEMS AS REQUIRED TO RETURN ITEM TO PRE-CONSTRUCTION CONDITIONS. 5. ALL PENETRATIONS REQUIRED FOR MECHANICAL WORK SHALL BE COORDINATED WITH OTHER DISCIPLINES TO ENSURE NO DISCREPANCIES HAVE BEEN OVERLOOKED OR NO DAMAGE OCCURS WHILE PERFORMING THIS WORK. ALL PENETRATIONS SHALL BE REPAIRED AND PATCHED WITH A COMPLETE WATER TIGHT SYSTEM TO MATCH EXISTING WALL OR ROOF. CONTRACTOR SHALL ENSURE NO LEAKS REMAIN IN ANY PENETRATION THROUGH WALL OR ROOF. 6. FIELD VERIFY ALL LOCATIONS OF EQUIPMENT AND MATERIALS FOR ALL HEATING, COOLING AND PLUMBING WORK. VERIFY WITH GOVERNMENT REPRESENTATIVE AND HISTORICAL BRANCH REPRESENTATIVE PRIOR TO MAKING ANY PENETRATIONS THROUGH THE ROOF OR WALLS OF THE BUILDING.

AutoCAD SHX Text

AutoCAD SHX Text

PLUMBING WORK PLAN - 2ND FLOOR

AutoCAD SHX Text

SCALE: 1/4"=1'-0"

AutoCAD SHX Text

NEW WORK KEYED NOTES

AutoCAD SHX Text

AutoCAD SHX Text PROVIDE NEW STAINLESS STEEL DOUBLE BOWL SINK WITH SPRAYER FOR KITCHEN AREA AS SPECIFIED ON ARCHITECTURAL SHEETS. PROVIDE NEW FAUCET SUPPLY LINES AND CONNECT HOT AND COLD WATER TO EXISTING VALVES UNDERNEATH CABINET. CONNECT SANITARY SEWER TO EXISTING SANITARY SEWER UNDER CABINETS.