Attachment_03__PRCING_SHEET.xlsx
XLSX spreadsheet 2 MB Posted
- Attached to
- LYJO RE-ROOF HISTORIC STRUCTURES Federal contract opportunity
- Solicitation number
- 140PS126Q0036
About this file
This is a Pricing Sheet template for a federal construction contract related to historic structure renovation at Lyndon B. Johnson National Historic Park. The pricing structure includes eight base contract line items and two optional bid items covering roofing and lightning protection work at multiple locations: Bruckner Barn, Cooler Building, Boyhood Home Barn, Boyhood Home Smokehouse, and Settlement Cabin.
The base contract (CLINs 0010–0080) comprises four roofing projects involving selective demolition, removal of existing wood shingles, structural repairs to wood joists and purlins, installation of synthetic cedar shake/shingles, vapor barriers, and weather barriers, with unit prices based on CSI codes and bare material, labor, and equipment costs. Four additional base items cover lightning protection system removal, refurbishment, and reinstallation (including copper cable, air terminals, arresters, and surge suppressors) at the four historic structures. Optional bid items include reroof work at Settlement Cabin (CLIN 100) and lightning protection installation there (CLIN 110). The pricing template requires offerors to provide bare unit prices, installer pricing with compounding factors (reflecting 60% labor/40% materials per DSC handbook guidance), and extended total prices on a lump-sum basis. The template incorporates general conditions percentages for permits, insurance, cleanup, and worker's compensation; mobilization and demobilization costs; and contingency, overhead, profit, bonding, inflation, and TERO fee markups. Currently, the spreadsheet shows multiple "#REF!" errors indicating incomplete formula references and missing cost data that contractors must populate with their pricing.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140PS126Q0036_Amd_0002.pdf | ||
| Attachment_05__Request_for_Information_0002.xlsx | XLSX spreadsheet | |
| Sol_140PS126Q0036_Amd_0001.pdf | ||
| Sol_140PS126Q0036.pdf | ||
| Attachment_05__Request_for_Information.xlsx | XLSX spreadsheet | |
| Attachment_02__Drawings.pdf | ||
| Attachment_04__Wage_Determination_TX20260193.pdf | ||
| Attachment_01__Project_Specifications.docx | DOCX document | |
| Attachment_06__Site_Visit_-_Construction.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
General Conditions
| ERROR:#REF! | ||
| Settlement Reroof Rehab stone | BARE UNIT PRICES | |
| PMIS | ERROR:#REF! |
| Item | CSI Number | Description | Qty | Unit | Bare Material Unit Price | Bare Labor (Base+Fringe) Unit Price | Bare Equipment Unit Price | Bare Unit Price | Notes |
| General Conditions | |||||||||
| 14126500020 | Permits rule of thumb, most cities, minimum | % | |||||||
| 13113300020 | Insurance, standard builders risk, minimum | % | |||||||
| 17413200020 | Cleaning up, clean up after job completion, allow, min | % | |||||||
| 13223300850 | Worker's compensation and liabilty insurance | % | |||||||
| % | |||||||||
| Sum of % Factors | 0.0% |
| 014523501500 | Concrete testing, cement, physical tests, ASTM C 150 | EA | $ - 0 | $ - 0 | $ - 0 | $ - 0 |
| 015213201250 | Storage boxes, rent per month, 20' x 8' | Month | $ - 0 | $ - 0 | ||
| 015409500030 | Respirator mask only, half face, silicone | EA | $ - 0 | $ - 0 | ||
| 015409500040 | Respirator cartridges, dust or asbestos, 2 req'd per mask | EA | $ - 0 | $ - 0 | ||
| 015409500060 | Respirator cartridges, combination vapor and dust, 2 req'd per mask | EA | $ - 0 | $ - 0 | ||
| 015416500100 | Forklift crew, all-terrain forklift, 45' lift, 35' reach, 9000 lb. capacity, weekly use | Week | $ - 0 | $ - 0 | ||
| 015423700090 | Scaffolding, steel tubular, regular, labor only to erect & dismantle, building exterior, wall face, 6'-4" x 5' frames, 1 to 5 stories, excludes planks | EA | $ - 0 | $ - 0 | ||
| 015423700965 | Scaffolding, steel tubular, heavy duty shoring, accessory, leveling jack, buy | EA | $ - 0 | $ - 0 | ||
| 015423701500 | Scaffolding, steel tubular, regular, accessory, cross brace, buy | EA | $ - 0 | $ - 0 | ||
| 015423701550 | Scaffolding, steel tubular, regular, accessory, guardrail post, buy | EA | $ - 0 | $ - 0 | ||
| 015423701650 | Scaffolding, steel tubular, regular, accessory, screw jack & plate, buy | EA | $ - 0 | $ - 0 | ||
| 015423701700 | Scaffolding, steel tubular, regular, accessory, sidearm bracket, buy | EA | $ - 0 | $ - 0 | ||
| 015423701800 | Scaffolding, steel tubular, regular, accessory, plank, buy, 2" x 10" x 16' long | EA | $ - 0 | $ - 0 | ||
| 015433402100 | Rent electric generator gas engine 1.5 kW to 3 kW, Incl. Hourly Oper. Cost. | Month | $ - 0 | $ - 0 | ||
| 015433405450 | Pressure Washer 5 gpm, 3000 psi, Incl. Hourly Oper. Cost. | Month | $ - 0 | $ - 0 | ||
| 015433406000 | Rent masonry saw 14" diameter 5 HP, Incl. Hourly Oper. Cost. | Month | $ - 0 | $ - 0 | ||
| 015433406410 | Rent toilet portable chemical, Incl. Hourly Oper. Cost. | Month | $ - 0 | $ - 0 | ||
| 015436501200 | Mobilization or demobilization, delivery charge for small equipment, placed in rear of, or towed by pickup truck | EA | $ - 0 | $ - 0 | ||
| 015436501200 | Mobilization or demobilization, each additional 5 miles haul distance, add | Miles | $ - 0 | $ - 0 | ||
| 015436501300 | Mobilization or demobilization, delivery charge for equipment, hauled on 3-ton capacity towed trailer | EA | $ - 0 | $ - 0 | ||
| 015436501300 | Mobilization or demobilization, each additional 5 miles haul distance, add | Miles | $ - 0 | $ - 0 | ||
| 015623101300 | Barricades, barricade tape, polyethylene, 7 mils thick, 3" wide x 300' long roll | EA | $ - 0 | $ - 0 | ||
| 015626500200 | Temporary fencing, chain link, rented up to 12 months, 6' high, 11 ga, to 1000' | LF | $ - 0 | $ - 0 | ||
| $ - 0 | $ - 0 |
Subtotal $ - 0
Total GC Percentage ERROR:#REF!
Unit Costs - A
| ERROR:#REF! | ERROR:#REF! | ||
| ERROR:#REF! | ERROR:#REF! | COMPOUNDING FACTORS | |
| PMIS | ERROR:#REF! | ERROR:#REF! |
Item CSI Number Description Qty Unit Bare Unit Price Installer Price nbuikema: nbuikema:
If no subcontractor for project (only a prime), change to 0% on cover page. Write comment that explains the installer price is based on having a prime do all of the work
| 60% Labor/40% M&E per DSC Handbook. RS Means indicates 70% Labor/30% M%E. Demo projects this should be evaluated for Park specific need. Change in cell as needed | Direct Unit Price | Total Direct Price | Price Schedule | Notes | ||||||
| 1 | Bruckner Barn Reroof with Synthetic Cedar Shingles | |||||||||
| 024119190164 | Selective demolition, rubbish handling, dust control device for dumpsters, cost to be added to demolition cost | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 024119190725 | Selective demolition, rubbish handling, dumpster, 20 C.Y., 5 ton capacity, weekly rental, includes one dump per week, cost to be added to demolition cost | Week | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 024119190950 | Selective demolition, rubbish handling, dumpster, alternate pricing method, disposal fee per ton, average for all sizes, cost to be added to demolition cost | Ton | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 024119192000 | Selective demolition, rubbish handling, 0'-50' haul, load, haul, dump and return, hand carried, cost to be added to demolition cost | C.Y. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 024119192045 | Selective demolition, rubbish handling, 0'-100' haul, load, haul, dump and return, wheeled, cost to be added to demolition cost | C.Y. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 024119195100 | Selective demolition, rubbish handling, over 8 C.Y. truck, loading & trucking, haul, per mile, includes 2 mile haul, cost to be added to demolition cost | C.Y. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 024119200200 | Selective demolition, dump charges, typical urban city, trees, brush, lumber, includes tipping fees only | Ton | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 024119200300 | Selective demolition, dump charges, typical urban city, rubbish only, includes tipping fees only | Ton | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 060505103440 | Selective demolition, wood framing, fascia boards, 1" x 8" | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 060505103490 | Selective demolition, wood framing, decking boards, 2" x 6" | L.F. | ERROR:#REF! | $ - 0 | ||||||
| 061110029000 | Miscellaneous wood blocking, minimum labor/equipment charge | Job | ERROR:#REF! | $ - 0 | ||||||
| 061323102302 | Wood framing, heavy mill timber, roof purlins, structural grade, 4" | B.F. | ERROR:#REF! | $ - 0 | ||||||
| 070505102220 | Selective demolition, thermal and moisture protection, roof edge, drip edge | L.F. | ERROR:#REF! | $ - 0 | ||||||
| 070505104670 | Selective demolition, thermal and moisture protection, roofing, wood shingles | S.F. | ERROR:#REF! | $ - 0 | ||||||
| 072510109960 | Weather barriers, minimum labor and equipment charge | Job | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 072613100900 | Vapor retarders, building paper, polyethylene vapor barrier, standard, 6 mil (.006" thick), 9' x 400' roll | Sq. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 073129161200 | Wood shakes, red cedar, 1/2" thick x 18" long, 8-1/2" exposure on roof | Sq. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 077126101300 | Reglet, counter flashing for galvanized steel, 26 ga., 12 wide | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| $ - 0 | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||||
| ERROR:#REF! | ERROR:#REF! | |||||||||
| 2 | Cooler Building Reroof with Synthetic Cedar Shingles | $ - 0 | ||||||||
| 024119190164 | Selective demolition, rubbish handling, dust control device for dumpsters, cost to be added to demolition cost | Ea. | ERROR:#REF! | $ - 0 | ||||||
| 024119190725 | Selective demolition, rubbish handling, dumpster, 20 C.Y., 5 ton capacity, weekly rental, includes one dump per week, cost to be added to demolition cost | Week | ERROR:#REF! | $ - 0 | ||||||
| 024119190950 | Selective demolition, rubbish handling, dumpster, alternate pricing method, disposal fee per ton, average for all sizes, cost to be added to demolition cost | Ton | ERROR:#REF! | $ - 0 | ||||||
| 024119192000 | Selective demolition, rubbish handling, 0'-50' haul, load, haul, dump and return, hand carried, cost to be added to demolition cost | C.Y. | ERROR:#REF! | $ - 0 | ||||||
| 024119192045 | Selective demolition, rubbish handling, 0'-100' haul, load, haul, dump and return, wheeled, cost to be added to demolition cost | C.Y. | ERROR:#REF! | $ - 0 | ||||||
| 024119195100 | Selective demolition, rubbish handling, over 8 C.Y. truck, loading & trucking, haul, per mile, includes 2 mile haul, cost to be added to demolition cost | C.Y. | ERROR:#REF! | $ - 0 | ||||||
| 024119200200 | Selective demolition, dump charges, typical urban city, trees, brush, lumber, includes tipping fees only | Ton | ERROR:#REF! | $ - 0 | ||||||
| 024119200300 | Selective demolition, dump charges, typical urban city, rubbish only, includes tipping fees only | Ton | ERROR:#REF! | $ - 0 | ||||||
| 060505103440 | Selective demolition, wood framing, fascia boards, 1" x 8" | L.F. | ERROR:#REF! | $ - 0 | ||||||
| 060505103490 | Selective demolition, wood framing, decking boards, 2" x 6" | L.F. | ERROR:#REF! | $ - 0 | ||||||
| 061110029000 | Miscellaneous wood blocking, minimum labor/equipment charge | Job | ERROR:#REF! | $ - 0 | ||||||
| 061323102302 | Wood framing, heavy mill timber, roof purlins, structural grade, 4" | B.F. | ERROR:#REF! | $ - 0 | ||||||
| 070505102220 | Selective demolition, thermal and moisture protection, roof edge, drip edge | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 070505104670 | Selective demolition, thermal and moisture protection, roofing, wood shingles | S.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 072510109960 | Weather barriers, minimum labor and equipment charge | Job | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 072613100900 | Vapor retarders, building paper, polyethylene vapor barrier, standard, 6 mil (.006" thick), 9' x 400' roll | Sq. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 073129161200 | Wood shakes, red cedar, 1/2" thick x 18" long, 8-1/2" exposure on roof | Sq. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| 077126101300 | Reglet, counter flashing for galvanized steel, 26 ga., 12 wide | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! |
| ERROR:#REF! | ERROR:#REF! | ||||||
| 3 | Boyhood Home - Barn Reroof with Synthetic Cedar Shingles | $ - 0 | |||||
| 024119190164 | Selective demolition, rubbish handling, dust control device for dumpsters, cost to be added to demolition cost | Ea. | ERROR:#REF! | $ - 0 | |||
| 024119190725 | Selective demolition, rubbish handling, dumpster, 20 C.Y., 5 ton capacity, weekly rental, includes one dump per week, cost to be added to demolition cost | Week | ERROR:#REF! | $ - 0 | |||
| 024119190950 | Selective demolition, rubbish handling, dumpster, alternate pricing method, disposal fee per ton, average for all sizes, cost to be added to demolition cost | Ton | ERROR:#REF! | $ - 0 | |||
| 024119192000 | Selective demolition, rubbish handling, 0'-50' haul, load, haul, dump and return, hand carried, cost to be added to demolition cost | C.Y. | ERROR:#REF! | $ - 0 | |||
| 024119192045 | Selective demolition, rubbish handling, 0'-100' haul, load, haul, dump and return, wheeled, cost to be added to demolition cost | C.Y. | ERROR:#REF! | $ - 0 | |||
| 024119195100 | Selective demolition, rubbish handling, over 8 C.Y. truck, loading & trucking, haul, per mile, includes 2 mile haul, cost to be added to demolition cost | C.Y. | ERROR:#REF! | $ - 0 | |||
| 024119200200 | Selective demolition, dump charges, typical urban city, trees, brush, lumber, includes tipping fees only | Ton | ERROR:#REF! | $ - 0 | |||
| 024119200300 | Selective demolition, dump charges, typical urban city, rubbish only, includes tipping fees only | Ton | ERROR:#REF! | $ - 0 | |||
| 060505103440 | Selective demolition, wood framing, fascia boards, 1" x 8" | L.F. | ERROR:#REF! | $ - 0 | |||
| 060505103490 | Selective demolition, wood framing, decking boards, 2" x 6" | L.F. | ERROR:#REF! | $ - 0 | |||
| 061110029000 | Miscellaneous wood blocking, minimum labor/equipment charge | Job | ERROR:#REF! | $ - 0 | |||
| 061323102302 | Wood framing, heavy mill timber, roof purlins, structural grade, 4" | B.F. | ERROR:#REF! | $ - 0 | |||
| 070505100420 | Selective demolition, thermal and moisture protection, gutters, mettal, edge hung | L.F. | ERROR:#REF! | $ - 0 | |||
| 070505102220 | Selective demolition, thermal and moisture protection, roof edge, drip edge | L.F. | ERROR:#REF! | $ - 0 | |||
| 070505104670 | Selective demolition, thermal and moisture protection, roofing, wood shingles | S.F. | ERROR:#REF! | $ - 0 | |||
| 070505105880 | Selective demolition, thermal and moistrue protection, roofing, steel corrugated/ribbed | S.F. | ERROR:#REF! | $ - 0 | |||
| 072510109960 | Weather barriers, minimum labor and equipment charge | Job | ERROR:#REF! | $ - 0 | |||
| 072613100900 | Vapor retarders, building paper, polyethylene vapor barrier, standard, 6 mil (.006" thick), 9' x 400' roll | Sq. | ERROR:#REF! | $ - 0 | |||
| 073129161200 | Wood shakes, red cedar, 1/2" thick x 18" long, 8-1/2" exposure on roof | Sq. | ERROR:#REF! | $ - 0 | |||
| 074113200400 | Steel roofing panels, on wood frame, corrugated or ribbed, galvanized 24 gauge | S.F. | ERROR:#REF! | $ - 0 | |||
| 077123104000 | Lead coated copper downspout, round, stock, 5" dia | L.F. | ERROR:#REF! | $ - 0 | |||
| 077123200800 | Elbows, copper round, 16 oz, 4" dia | Ea. | ERROR:#REF! | $ - 0 | |||
| 077123300700 | Copper Gutters, half round, 16 oz., stock units, 4" wide | L.F. | ERROR:#REF! | $ - 0 | |||
| 077123305290 | Gutter outlets, lead coated copper, 2-3/8" round | Ea. | ERROR:#REF! | $ - 0 | |||
| 077126101300 | Reglet, counter flashing for galvanized steel, 26 ga., 12 wide | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! |
| $ - 0 | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| ERROR:#REF! | ERROR:#REF! | |||||||
| 4 | Boyhood Home - Reroof Smokehouse with Synthetic Cedar Shingles | $ - 0 | ||||||
| 024119190164 | Selective demolition, rubbish handling, dust control device for dumpsters, cost to be added to demolition cost | Ea. | ERROR:#REF! | $ - 0 | ||||
| 024119190725 | Selective demolition, rubbish handling, dumpster, 20 C.Y., 5 ton capacity, weekly rental, includes one dump per week, cost to be added to demolition cost | Week | ERROR:#REF! | $ - 0 | ||||
| 024119190950 | Selective demolition, rubbish handling, dumpster, alternate pricing method, disposal fee per ton, average for all sizes, cost to be added to demolition cost | Ton | ERROR:#REF! | $ - 0 | ||||
| 024119192000 | Selective demolition, rubbish handling, 0'-50' haul, load, haul, dump and return, hand carried, cost to be added to demolition cost | C.Y. | ERROR:#REF! | $ - 0 | ||||
| 024119192045 | Selective demolition, rubbish handling, 0'-100' haul, load, haul, dump and return, wheeled, cost to be added to demolition cost | C.Y. | ERROR:#REF! | $ - 0 | ||||
| 024119195100 | Selective demolition, rubbish handling, over 8 C.Y. truck, loading & trucking, haul, per mile, includes 2 mile haul, cost to be added to demolition cost | C.Y. | ERROR:#REF! | $ - 0 | ||||
| 024119200200 | Selective demolition, dump charges, typical urban city, trees, brush, lumber, includes tipping fees only | Ton | ERROR:#REF! | $ - 0 | ||||
| 024119200300 | Selective demolition, dump charges, typical urban city, rubbish only, includes tipping fees only | Ton | ERROR:#REF! | $ - 0 | ||||
| 060505103440 | Selective demolition, wood framing, fascia boards, 1" x 8" | L.F. | ERROR:#REF! | $ - 0 | ||||
| 060505103490 | Selective demolition, wood framing, decking boards, 2" x 6" | L.F. | ERROR:#REF! | $ - 0 | ||||
| 061110029000 | Miscellaneous wood blocking, minimum labor/equipment charge | Job | ERROR:#REF! | $ - 0 | ||||
| 061323102302 | Wood framing, heavy mill timber, roof purlins, structural grade, 4" | B.F. | ERROR:#REF! | $ - 0 | ||||
| 070505102220 | Selective demolition, thermal and moisture protection, roof edge, drip edge | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 070505104670 | Selective demolition, thermal and moisture protection, roofing, wood shingles | S.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 072510109960 | Weather barriers, minimum labor and equipment charge | Job | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 072613100900 | Vapor retarders, building paper, polyethylene vapor barrier, standard, 6 mil (.006" thick), 9' x 400' roll | Sq. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 073129161200 | Wood shakes, red cedar, 1/2" thick x 18" long, 8-1/2" exposure on roof | Sq. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 077126101300 | Reglet, counter flashing for galvanized steel, 26 ga., 12 wide | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| $ - 0 | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| ERROR:#REF! | ERROR:#REF! | |||||||
| 5 | Bruckner Barn Lightning Protection | $ - 0 | ||||||
| 130505450030 | Air terminal & base, copper, 1/2" dia x 12", to 75' high, selective demolition | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 130505450070 | cable, copper, 220 lb per thousand feet, to 75' high, selective demolition | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 130505450110 | Arrester, to ground, 175 V AC, selective demolition | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 260590101800 | Lightning surge supperssor | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 260505109000 | Minimal labor/equipment charge | Ea. | ERROR:#REF! | $ - 0 | ||||
| 264113132000 | Lightning protection cable, copper, 220 lb per thousand feet, to 75' high | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113133000 | Lightning arrester, 175 V AC to ground | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134020 | Air terminal, copper, 1/2" x 12" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134220 | Copper air terminal base, bolted base for copper terminal, 1/2" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134270 | Copper air terminal base, tee connector for copper terminal, 1/2" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134700 | cable support, copper, loop fastener | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! |
| $ - 0 | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| ERROR:#REF! | ERROR:#REF! | |||||||
| 6 | Cooler Building Lightning Protection | $ - 0 | ||||||
| 130505450030 | Air terminal & base, copper, 1/2" dia x 12", to 75' high, selective demolition | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 130505450070 | cable, copper, 220 lb per thousand feet, to 75' high, selective demolition | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 130505450110 | Arrester, to ground, 175 V AC, selective demolition | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 260590101800 | Lightning surge supperssor | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 260505109000 | Minimal labor/equipment charge | Ea. | ERROR:#REF! | $ - 0 | ||||
| 264113132000 | Lightning protection cable, copper, 220 lb per thousand feet, to 75' high | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113133000 | Lightning arrester, 175 V AC to ground | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134020 | Air terminal, copper, 1/2" x 12" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134220 | Copper air terminal base, bolted base for copper terminal, 1/2" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134270 | Copper air terminal base, tee connector for copper terminal, 1/2" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134700 | cable support, copper, loop fastener | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! |
| $ - 0 | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| $ - 0 | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| ERROR:#REF! | ERROR:#REF! | |||||||
| 7 | Boyhood House - Barn Lightning Protection | $ - 0 | ||||||
| 130505450030 | Air terminal & base, copper, 1/2" dia x 12", to 75' high, selective demolition | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 130505450070 | cable, copper, 220 lb per thousand feet, to 75' high, selective demolition | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 130505450110 | Arrester, to ground, 175 V AC, selective demolition | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 260590101800 | Lightning surge supperssor | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 260505109000 | Minimal labor/equipment charge | Ea. | ERROR:#REF! | $ - 0 | ||||
| 264113132000 | Lightning protection cable, copper, 220 lb per thousand feet, to 75' high | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113133000 | Lightning arrester, 175 V AC to ground | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134020 | Air terminal, copper, 1/2" x 12" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134220 | Copper air terminal base, bolted base for copper terminal, 1/2" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134270 | Copper air terminal base, tee connector for copper terminal, 1/2" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134700 | cable support, copper, loop fastener | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| $ - 0 | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||
| ERROR:#REF! | ERROR:#REF! | |||||||
| 8 | Boyhood House - Smokehouse Lightning Protection | $ - 0 | ||||||
| 130505450030 | Air terminal & base, copper, 1/2" dia x 12", to 75' high, selective demolition | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 130505450070 | cable, copper, 220 lb per thousand feet, to 75' high, selective demolition | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 130505450110 | Arrester, to ground, 175 V AC, selective demolition | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 260590101800 | Lightning surge supperssor | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 260505109000 | Minimal labor/equipment charge | Ea. | ERROR:#REF! | $ - 0 | ||||
| 264113132000 | Lightning protection cable, copper, 220 lb per thousand feet, to 75' high | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113133000 | Lightning arrester, 175 V AC to ground | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134020 | Air terminal, copper, 1/2" x 12" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134220 | Copper air terminal base, bolted base for copper terminal, 1/2" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134270 | Copper air terminal base, tee connector for copper terminal, 1/2" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||
| 264113134700 | cable support, copper, loop fastener | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! |
| $ - 0 | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||||
| $ - 0 | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||||
| ERROR:#REF! | ERROR:#REF! | ||||||||
| A | Bid Option No. 01 Reroof Settlement Cabin with Synthetic Cedar Shingles | $ - 0 | |||||||
| 024119190164 | Selective demolition, rubbish handling, dust control device for dumpsters, cost to be added to demolition cost | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 024119190725 | Selective demolition, rubbish handling, dumpster, 20 C.Y., 5 ton capacity, weekly rental, includes one dump per week, cost to be added to demolition cost | Week | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 024119190950 | Selective demolition, rubbish handling, dumpster, alternate pricing method, disposal fee per ton, average for all sizes, cost to be added to demolition cost | Ton | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 024119192000 | Selective demolition, rubbish handling, 0'-50' haul, load, haul, dump and return, hand carried, cost to be added to demolition cost | C.Y. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 024119192045 | Selective demolition, rubbish handling, 0'-100' haul, load, haul, dump and return, wheeled, cost to be added to demolition cost | C.Y. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 024119195100 | Selective demolition, rubbish handling, over 8 C.Y. truck, loading & trucking, haul, per mile, includes 2 mile haul, cost to be added to demolition cost | C.Y. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 024119200200 | Selective demolition, dump charges, typical urban city, trees, brush, lumber, includes tipping fees only | Ton | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 024119200300 | Selective demolition, dump charges, typical urban city, rubbish only, includes tipping fees only | Ton | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 060505103440 | Selective demolition, wood framing, fascia boards, 1" x 8" | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 060505103490 | Selective demolition, wood framing, decking boards, 2" x 6" | L.F. | ERROR:#REF! | $ - 0 | |||||
| 061110029000 | Miscellaneous wood blocking, minimum labor/equipment charge | Job | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 061323102302 | Wood framing, heavy mill timber, roof purlins, structural grade, 4" | B.F. | ERROR:#REF! | $ - 0 | |||||
| 070505102220 | Selective demolition, thermal and moisture protection, roof edge, drip edge | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 070505104670 | Selective demolition, thermal and moisture protection, roofing, wood shingles | S.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 072510109960 | Weather barriers, minimum labor and equipment charge | Job | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 072613100900 | Vapor retarders, building paper, polyethylene vapor barrier, standard, 6 mil (.006" thick), 9' x 400' roll | Sq. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 073129161200 | Wood shakes, red cedar, 1/2" thick x 18" long, 8-1/2" exposure on roof | Sq. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 077126101300 | Reglet, counter flashing for galvanized steel, 26 ga., 12 wide | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| $ - 0 | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||||
| ERROR:#REF! | ERROR:#REF! | ||||||||
| B | Bid Option No. 02 Settlement Cabin Lightning Protection | ||||||||
| 130505450030 | Air terminal & base, copper, 1/2" dia x 12", to 75' high, selective demolition | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 130505450070 | cable, copper, 220 lb per thousand feet, to 75' high, selective demolition | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 130505450110 | Arrester, to ground, 175 V AC, selective demolition | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 260590101800 | Lightning surge supperssor | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 260505109000 | Minimal labor/equipment charge | Ea. | ERROR:#REF! | $ - 0 | |||||
| 264113132000 | Lightning protection cable, copper, 220 lb per thousand feet, to 75' high | L.F. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 264113133000 | Lightning arrester, 175 V AC to ground | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 264113134020 | Air terminal, copper, 1/2" x 12" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 264113134220 | Copper air terminal base, bolted base for copper terminal, 1/2" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 264113134270 | Copper air terminal base, tee connector for copper terminal, 1/2" | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| 264113134700 | cable support, copper, loop fastener | Ea. | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||
| ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |||||||
| ERROR:#REF! | ERROR:#REF! | ||||||||
| Subtotal | ERROR:#REF! | Compounded % | |||||||
| Design Contingency | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||||
| Government and General GC, Historic Preservation | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||||
| Overhead and Profit | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||||
| Bond, Inflation, Contract Type | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ||||||
| TERO Fee | ERROR:#REF! |
nbuikema: nbuikema:
Value will be standalone, individual CLIN on Price Schedule nbuikema: nbuikema:
If no subcontractor for project (only a prime), change to 0% on cover page. Write comment that explains the installer price is based on having a prime do all of the work
60% Labor/40% M&E per DSC Handbook. RS Means indicates 70% Labor/30% M%E. Demo projects this should be evaluated for Park specific need. Change in cell as needed TOTAL ERROR:#REF!
Contract Price Schedule
| Contract Price Schedule | |||||
| National Park Service (NPS) - Denver Service Center (DSC) | 4/25-18 | |||||
| Solicitation Number: 140PS126Q0036 | |||||
| PARK - PMIS (Project Management Information System): | LYNDON B JOHNSON, PMIS: 241282, 241283, 250239 | ||||
| Developed Area: | |||||
| Project Title: | REROOF HISTORIC BARNS & SETTLEMENT CABIN WITH STONE REPOINTING AND STRUCTUARL REPAIRS AND BOYHOOD BARN AND SMOKEHOUSE | ||||
| Notice: Offerors are required to submit, a minimum, an offer that conforms to the solicitation documents with pricing for Base line items and all | |||||
| option line items. Failure to do so may render the proposal unacceptable. On lump-sum line items, provide the total price only. For all unit-priced | |||||
| line items, provide the unit price and the extended total price. If no specific line item exists for a portion of the work, include the costs in a related | |||||
| item. In case of error in calculation of extended prices, the unit price governs. In case of error in summation, the total of the corrected amounts | |||||
| govern. Round totals and extended prices to whole dollars. Refer to solicitation section “H” for additional information regarding contract options | |||||
| Contract Line Item Number (CLIN) | Contract Line Item (CLI) Title | Quantity | Unit of Measure | Unit Price | Total Price |
| 0010 | Bruckner Barn Reroof with Synthetic Cedar Shingles | 1 | LS | ||
| 0020 | Cooler Building Reroof with Synthetic Cedar Shingles | 1 | LS | ||
| 0030 | Boyhood Home - Barn Reroof with Synthetic Cedar Shingles | 1 | LS | ||
| 0040 | Boyhood Home - Reroof Smokehouse with Synthetic Cedar Shingles | 1 | LS | ||
| 0050 | Bruckner Barn Lightning Protection | 1 | LS | ||
| 0060 | Cooler Building Lightning Protection | 1 | LS | ||
| 0070 | Boyhood House - Barn Lightning Protection | 1 | LS | ||
| 0080 | Boyhood House - Smokehouse Lightning Protection | 1 | LS | ||
| 0090 | INTENTIONALLY BLANK | ||||
| TOTAL BASE PRICE (Contract Line Item Number 0010 through 0080) | |||||
| 100 | BID OPTION NO. 01 REROOF SETTLEMENT CABIN WITH SYNTHETIC CEDAR SHINGLES | 1 | LS | ||
| 110 | BID OPTION NO 02 SETTLEMENT CABIN LIGHTNING PROTECTION | 1 | LS | ||
| 120 | INTENTIONALLY BLANK | ||||
| 130 | INTENTIONALLY BLANK | ||||
| TOTAL PRICE FOR ALL OPTIONS (Contract Line Item Number 100 through 110) | |||||
| TOTAL PROPOSED PRICE - BASE PLUS ALL OPTIONS (Contract Line Item Number 0010 through 110) | |||||
| All measurement and payment information is included in Division 01 Specifications Section 01 27 00 Definition of Contract Line Items. |
Units Abbreviations image1.jpg image2.jpg image3.jpg image4.jpg
File details come from the government source that posted it. Updated .