About this file

This solicitation and concept drawing outline requirements for base infrastructure additions and repairs at Shaw Air Force Base in Sumter, South Carolina. The work includes demolishing several buildings, structures, and fencing; installing new fencing, gates, roadway, and improved driving surfaces; and conducting environmental surveys. The solicitation is set aside for historically underutilized business zone firms. Interested parties must register on beta.sam.gov and subscribe to receive procurement announcements. Questions must be submitted by email to the specified addresses. The contractor will furnish all labor, materials, permits, and supervision. Payment will be made through the Wide Area Workflow system, and contractors must register on wawf.ef.mil. Bids are due by August 20th, and the award will be made based on price to the responsible bidder offering the most advantageous proposal to the government.

View the file

Other files for this federal contract opportunity

Other files attached to Add/Repair Base Infrastructure, newest first.
File Type Posted
Attachment 08A Wage Determinations.pdf PDF
Attachment 15 QandA.pdf PDF
Attachment 01 Revised _SOW_ VLSB 15-0007_ Add Repair Base Infrastructure 07-30-20.pdf PDF
Solicitation Amendment FA480320B00010005 SF 30.pdf PDF
Attachment 13A - Financial_Information_Request.docx DOCX document
Solicitation Amendment FA480320B00010004.pdf PDF
Solicitation Amendment FA480320B00010003 SF 30.pdf PDF
Attachment 14a Pre site visit Attendance Sheet_13 Jul 2020.pdf PDF
Solicitation Amendment FA480320B00010002 SF 30 (1).pdf PDF
Solicitation Amendment FA480320B00010001 SF 30.pdf PDF
Attachment 14 Pre site Visit Attendace Sheet_Add Repair Base Infrastructure.pdf PDF
Attachment 12 - Cost Estimate Sheet.xlsx XLSX spreadsheet
Attachment 13_-_Financial_Information_Request.docx DOCX document
Attachment 06 - Trash Grate Drawings.pdf PDF
Attachment 01 -SOW VLSB 15-0007-Add Repair_13 May 2020.pdf PDF
Attachment 03 - 2014 Archaeological Survey.pdf PDF
Attachment 08 - Wage Determinations.pdf PDF
Attachment 04 - Archaeological Site Map.pdf PDF
Attachment 11 - Add_Repair Photos.pdf PDF
Attachment 05 - Courtesy List Environmental Consultants October 2014.pdf PDF
Attachment 07 - Shaw AFB Design Constr Change 2 dated 21 Aug 2018.pdf PDF
Attachment 10 - CONTRACTOR EAL Base Pass Request.doc DOC document
Attachment 09 - Annual Rainfall.pdf PDF
Solicitation - FA480320B0001.pdf PDF
Show all 24

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B A

S E

IN

FR

A S

TR

U

C

TU

R E

OVERALL PLAN

FA480320B0001

Attachment 2

VLSB 15-0007 Drawing

AutoCAD SHX Text

SHAW DRIVE

AutoCAD SHX Text

FRIERSON RD. S.C. HIGHWAY NO. 364

AutoCAD SHX Text INSTALL NEW 30 FOOT CRASH RATED (K-12) ROLLING GATE TIE IN NEW ROLLING GATE TO EXISTING FENCING. INSTALL APPROPRIATE MARKINGS AND STOP SIGNS AS NEEDED FOR INTERSECTION

AutoCAD SHX Text 30 FOOT DOUBLE CHAIN LINK GATE WITH CONCRETE JERSEY BARRIERS PLACED ON THE SECURE SIDE OF THE FENCE.

AutoCAD SHX Text

APPROXIMATE LOCATION OF WETLAND BOUNDARY

AutoCAD SHX Text

ATTACH THE FENCING ON THE BRIDGE

AutoCAD SHX Text

TIE BACK INTO TO THE EXISTING PERIMETER FENCE

AutoCAD SHX Text

INSTALL TRASH GRATE EXAMPLE SHOWN IN ATTACHMENT 06

AutoCAD SHX Text

EXISTING TRASH GRATE TO BE DEMOLISHED

AutoCAD SHX Text

EXISTING IMPROVED SURFACE

AutoCAD SHX Text

75 FOOT ROW TO BE CLEARED FOLLOWING PROPERTY EDGE WHERE SHOWN

AutoCAD SHX Text

NEW PCC ASPHALT ROAD 25 FOOT WIDE WITH PAVEMENT MARKINGS AND SIGNS

AutoCAD SHX Text

7 FOOT CHAIN LINK FENCE WITH THREE STRAND OF BARBED WIRE EACH WAY ON TOP

AutoCAD SHX Text

APPROXIMATE PROPERTY LINE

AutoCAD SHX Text

APPROXIMATE PROPERTY LINE

AutoCAD SHX Text

APPROXIMATE PROPERTY LINE

AutoCAD SHX Text

DOG KENNEL TO BE DEMOLISHED

AutoCAD SHX Text

FURNITURE STORE (SEVERAL INDIVIDUAL BUILDINGS) ALL TO BE DEMOLISHED

AutoCAD SHX Text

STANDALONE CONCRETE SLAB TO BE DEMOLISHED

AutoCAD SHX Text

SKATING RINK TO BE DEMOLISHED

AutoCAD SHX Text

WELL PUMP HOUSE AND TANK WITH FENCE TO BE DEMOLISHED

AutoCAD SHX Text

EXISTING FENCE TO BE DEMOLISHED BETWEEN NEW FENCE TIE IN'S

AutoCAD SHX Text PROVIDE IMPROVED SURFACE ON THE SECURE SIDE OF THE FENCE APPROXIMATELY 11 FEET WIDE

AutoCAD SHX Text

APPROXIMATE PROPERTY LINE

AutoCAD SHX Text 20 FOOT ROW TO BE CLEARED PLACE FENCE 5 FEET INSIDE OF CLEARING PROVIDE IMPROVED SURFACE ON THE SECURE SIDE OF THE FENCE APPROXIMATELY 12 FEET WIDE

AutoCAD SHX Text EXISTING FENCE TO BE DEMOLISHED BETWEEN NEW FENCE TIE IN AND EXISTING VEHICLE GATE

AutoCAD SHX Text

EXISTING VEHICLE GATE TO BE REMOVED AND GIVEN BACK TO THE GOVERNMENT

AutoCAD SHX Text

CLOSEST EXISTING LIGHT FIXTURE TO THE NEW GATE

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

CHK

AutoCAD SHX Text

OF

AutoCAD SHX Text

PROJECT NO.:

AutoCAD SHX Text

SHAW AIR FORCE BASE

AutoCAD SHX Text

SUMTER, SOUTH CAROLINA

AutoCAD SHX Text

PROJECT MANAGER

AutoCAD SHX Text

IPT TECH. BRANCH HEAD

AutoCAD SHX Text

CHIEF ENG/ARCH

AutoCAD SHX Text

VLSB 15-0007

AutoCAD SHX Text N

Sheets and Views
C-001