Attachment 0010d.4 – E151 – Media Converter 04-FMECA.xlsx

XLSX spreadsheet 35 KB Posted

Attached to
RFP for Integrated Battle Command System (IBCS) LRIP/FRP
Solicitation number
W31P4Q-20-R-0015
Issued by

About this file

This document contains an Excel file attachment and federal contract opportunity related to an Integrated Battle Command System hardware production effort. The Excel file provides a failure modes and effects analysis for a media converter component used in the system. It details four potential failure modes, their effects, severity classifications, and compensating provisions. The federal contract opportunity is a solicitation from the Department of the Army to produce IBCS hardware in accordance with supplied technical data packages and specifications. It requires maintaining approved software and firmware updates, cybersecurity, and authority to operate on existing hardware. Questions are due by December 10, 2020 and the opportunity is only open to contractors who met entrance criteria and were approved by the Integrated Fires Mission Command Project Office.

View the file

Other files

File Type Posted
Attachment 0019 - Section L - Instructions Conditions and Notices to Offerors - 7DEC2020.docx DOCX document
Attachment 0010a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 0010a.5 – R005 SCIM-FMECA.xlsx XLSX spreadsheet
Attachment 0013i - D-IBCS-0473_Adv_NetMgr.pdf PDF
Attachment 0010e.4 – E102d thru E111 Vid Extender-FMECA.xlsx XLSX spreadsheet
Attachment 0022a.1.j - PL-ALH-215333 00 S-280 CASS INSTA.pdf PDF
Attachment 0010d.10 – E157 KVM Switch 2 Shelter-FMECA.xlsx XLSX spreadsheet
Attachment 0004a - EOC Acceptance Test Procedures_FINAL.docx DOCX document
Attachment 0010h - SWFMEA Results.xlsx XLSX spreadsheet
Attachment 0010d.1 – E123 TMSS – ECU-FMECA.xlsx XLSX spreadsheet
Attachment 0005 - Software Installation Instructions.docx DOCX document
Attachment 0026 - Use of Existing Government-Furnished Property.xlsx XLSX spreadsheet
Attachment 0010a.6 – R006 TIMING UNIT-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Exhibit C- IBCS DSL - 24NOV2020.docx DOCX document
Attachment 0004d - Operator Procedures For IFMC GSIL.docx DOCX document
Attachment 0010c.11 – E061 Isolation Router Red-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.6 – E051 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.10 – R016 thru R025 Media Converter Module-FMECA.xlsx XLSX spreadsheet
Attachment 0018 - IBCS LRIP FRP IDIQ Pricing Template_29Oct2020 v.3.xlsx XLSX spreadsheet
Attachment 0013c - IBCS-A301-003 Vol II Instructor Guide_redacted.pdf PDF
Attachment 0010e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0016 - Example Cage Code and Cognizant DCMA DCAA Information.xlsx XLSX spreadsheet
Attachment 0022a.1.e - ALH-215333 00 S-280 CASS INSTALLA.pdf PDF
Attachment 0010c.15 – E068 Media Converter 02 – FMECA.xlsx XLSX spreadsheet
Attachment 0010b.4 – E013 ADSI Shelter – Misc Equip-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.10 – E060 Shelter Switch – 02-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.11 – E149 – Table 5 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.13 – E063 Isolation Router Black-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.15 – R033 Media Converter Module 12-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.5 – E029 KVM Switch 1 Shelter Stack-FMECA.xlsx XLSX spreadsheet
Attachment 0004c - ECT Acceptance Test Procedures_FINAL.DOCX DOCX document
Attachment 0010e.6 – E143 – ICE UPS-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.6 – E030 KVM Console-FMECA.xlsx XLSX spreadsheet
Attachment 0012 - Risk Management Plan.pdf PDF
Attachment 0013a -A293-004 ETM 60 Percent Draft_redacted.pdf PDF
Attachment 0022a.2 - PDRS Support information for integration task.pptx PPTX presentation
Attachment 0010c.16 – E069 Media Converter 03 - FMECA.xlsx XLSX spreadsheet
Attachment 0022a.1.f - EOC Shelter views.pptx PPTX presentation
Attachment 0001 - IBCS LRIP FRP Statement of Work - 24NOV2020.docx DOCX document
Attachment 0010a.2 – R002 BPU-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.4 – R004 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 0022a.1.g - PL-ALH-209032 00 CABLE ASSEMBLY C.pdf PDF
Attachment 0010b.7 – E031 R112 Shelter – Server Stack – 01-FEMCA.xlsx XLSX spreadsheet
Attachment 0004 - Acceptance Test Plan.docx DOCX document
Attachment 0006 - Obsolete Parts List.pdf PDF
Attachment 0010a.11 – R029 PFPU SSHD-1—FMECA.xlsx XLSX spreadsheet
Attachment 0011- Cost Report and Plan.pdf PDF
Attachment 0010d.3 – E150 S-280 PEV-FMECA.xlsx XLSX spreadsheet
Show 40 more

Latest 50 of 128 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pivot Table

W31P4Q-20-R-0015
ATTACHMENT 0010d.4
TAB 1 OF 4
Row LabelsSum of CmCount of Failure Mode Description
Does not operate1.48E-052
Intermittent6.72E-061
Degraded (Functional)0.00E+001
Grand Total2.15E-054

Prelim Analysis

W31P4Q-20-R-0015
ATTACHMENT 0010d.4
TAB 2 OF 4
PRELIMINARY ANALYSIS:Major End Item:Shelter
Parent LRU:E151-Media Converter-04 (RED)
Component:MEDIA CONVERTOR, WIN-T AXX
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =2.15E-05
Failure ModesCount of
Failure ModesSeverity
ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Does not operate250.0%Category II2Does not operate1.48E-052
Degraded (Functional)125.0%Does not operate1Intermittent6.72E-061
Intermittent125.0%Intermittent1Degraded (Functional)0.00E+001
Grand Total4Category III1Grand Total2.15E-054
Does not operate1
Category IV1
Degraded (Functional)1
Grand Total4

Cat I and II

W31P4Q-20-R-0015
ATTACHMENT 0010d.4
TAB 3 OF 4
Major End Item:Shelter
Parent LRU:E151-Media Converter-04 (RED)
Component:MEDIA CONVERTOR, WIN-T AXX
Mission Phase-Operational Mode:All Phases
FPMH:9.5583
t:72
Cr = ∑Cm =2.75E-04
Modified Cr =4.30E-05
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R
Failure Effect atFailure Detection MethodCompensating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
6339CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADoes not operateHardware failure or software defectLoss of functionLoss of WIN-T Red DataDegraded Mission due to loss of External Sensor DataN/AN/AOB-420-80N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.50009.56E-061.72E-041.72E-05
6340CONVERTS FIBER TO COPPER - FOR WIN-T RED DATAIntermittentHardware failure or software defectIntermittent continuityProbable Loss of WIN-T Red DataProbable Degraded Mission due to loss of External Sensor DataN/AN/AOB-420-80N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.25009.56E-068.60E-058.60E-06

Data E151

W31P4Q-20-R-0015
ATTACHMENT 0010d.4
TAB 4 OF 4
Major End Item:Shelter
Parent LRU:E151-Media Converter-04 (RED)
Component:MEDIA CONVERTOR, WIN-T AXX
Mission Phase-Operational Mode:All Phases
FPMH:0.7463
t:72
Cr = ∑Cm =2.15E-05
Modified Cr =3.36E-06
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R
Failure Effect atFailure Detection MethodCompensating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
6338CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADoes not operateHardware failure or software defectLoss of functionLoss of WIN-T Red DataDegraded Mission due to loss of External Sensor DataN/AN/AOB-450-01VI-055-01 (Shelter PDP CB-18 Trips when Reset)TBDCategory IIIEOCs are RedundantCategory III0.050.050.50007.46E-071.34E-061.34E-06
6339CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADoes not operateHardware failure or software defectLoss of functionLoss of WIN-T Red DataDegraded Mission due to loss of External Sensor DataN/AN/AOB-420-80N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.50007.46E-071.34E-051.34E-06
6340CONVERTS FIBER TO COPPER - FOR WIN-T RED DATAIntermittentHardware failure or software defectIntermittent continuityProbable Loss of WIN-T Red DataProbable Degraded Mission due to loss of External Sensor DataN/AN/AOB-420-80N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.25007.46E-076.72E-066.72E-07
6341CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADegraded (Functional)Hardware failure or software defectLoss of noncritical functionLoss of noncritical functionLoss of noncritical functionN/AN/AOB-420-80N/ATBDCategory IVEOCs are RedundantCategory IV0.000.000.25007.46E-070.00E+000.00E+00