Attachment 0010c.16 – E069 Media Converter 03 - FMECA.xlsx

XLSX spreadsheet 40 KB Posted

Attached to
RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
Solicitation number
W31P4Q-20-R-0015
Issued by
Department of the Army Materiel Command Contracting Command Redstone Arsenal

About this file

This document includes an attachment and federal contract opportunity related to an Integrated Battle Command System procurement. The attachment provides failure mode and effects analysis for a media converter component used in the system. It details various failure modes, their potential effects at different levels, severity classifications, and compensating provisions. The federal contract opportunity is a solicitation for the Integrated Battle Command System Low Rate Initial Production/Full Rate Production hardware segment. It involves producing hardware end items according to technical data packages and critical item development specifications. Engineering changes may be required for obsolescence, new capabilities, and export considerations. Questions are due by December 10, 2020 and the opportunity is only for contractors that met entrance criteria approved by the Integrated Fires Mission Command Project Office within the Department of the Army Materiel Command Contracting Command at Redstone Arsenal.

View the file

Other files for this federal contract opportunity

Other files attached to RFP for Integrated Battle Command System (IBCS) LRIP/FRP, newest first.
File Type Posted
EXHIBIT A - CONTRACT DATA ITEM REQUIREMENTS LIST (CDRL) - 24NOV2020.pdf PDF
Exhibit C- IBCS DSL - 24NOV2020.docx DOCX document
Attachment 0002 - AIAMD System of Systems (SoS)(MIS-PRF-56500).pdf PDF
Attachment 0004b - Relay Acceptance Test Procedures_FINAL.docx DOCX document
Attachment 0004d - Operator Procedures For IFMC GSIL.docx DOCX document
Attachment 0005 - Software Installation Instructions.docx DOCX document
Attachment 0008 - AIAMD IUID Plan Appendix A - IUID Candidates List Data Items.pdf PDF
Attachment 0009 - R and M Prediction Report.docx DOCX document
Attachment 0010a.3 – R003 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.7 – R007 Relay Network Switch-Parvus Switch-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 0010c.3 – E048 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.8 – E053 Shelter Time Server-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.9 – E059 Shelter Switch – 01-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.8 – E153 RS112 Server -07 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0012 - Risk Management Plan.pdf PDF
Attachment 0013c - IBCS-A301-003 Vol II Instructor Guide_redacted.pdf PDF
Attachment 0013f - D-IBCS-0428-001_Delta_Software_SG_redacted.pdf PDF
Attachment 0013g - D-IBCS-0471_Delta2_Suppl_PE_redacted.pdf PDF
Attachment 0014 RevC - Technical Library.docx DOCX document
Attachment 0016 - Example Cage Code and Cognizant DCMA DCAA Information.xlsx XLSX spreadsheet
Attachment 0022a - CASS to PDRS.docx DOCX document
Attachment 0022a.1.e - ALH-215333 00 S-280 CASS INSTALLA.pdf PDF
Attachment 0022a.1.h - PL-ALH-211130 00 CABLE ASSEMBLY C.pdf PDF
Attachment 0022a.4 - CASS Task Purpose.v2.pptx PPTX presentation
Attachment 0025 - DD254.pdf PDF
Attachment 0010b.6 – E030 KVM Console-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.5 – R005 SCIM-FMECA.xlsx XLSX spreadsheet
Attachment 0013i - D-IBCS-0473_Adv_NetMgr.pdf PDF
W31P4Q-20-R-0015- LRIP FRP - 25NOV2020.pdf PDF
Exhibit B - LRIP FRP TO 0001 DD1423 CDRLs_24NOV2020.pdf PDF
Attachment 0001 - IBCS LRIP FRP Statement of Work - 24NOV2020.docx DOCX document
Attachment 0010a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.2 – R002 BPU-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.6 – R006 TIMING UNIT-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.12 – R030 PFPU SSHD-1—FMECA.xlsx XLSX spreadsheet
Attachment 0010a.14 – R032 Media Converter Module 11-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.1 – E001 28VDC Pwr Supply Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.10 – E034 R112 Shelter – Server Stack – 04-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.6 – E051 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.11 – E061 Isolation Router Red-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.12 – E062 Shelter Router-Red-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.1 – E123 TMSS – ECU-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.4 – E151 – Media Converter 04-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.6 – E153 RS112 Server -05 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.3 – E092 thru E101 Wkstn Display-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.5 – E122 – EMI Tent PDU-FMECA.xlsx XLSX spreadsheet
Show all 50

RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pivot Table

W31P4Q-20-R-0015
ATTACHMENT 0010c.16
TAB 1 of 4
Row LabelsSum of CmCount of Failure Mode Description
Does not operate1.48E-052
Intermittent6.72E-061
Degraded (Functional)0.00E+001
Grand Total2.15E-054

Prelim Analysis

W31P4Q-20-R-0015
ATTACHMENT 0010c.16
TAB 2 of 4
PRELIMINARY ANALYSIS:Major End Item:Shelter
Parent LRU:E069-Media Converter-03 ICE)
Component:MEDIA CONVERTOR, WIN-T A334
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =2.15E-05
Failure ModesCount of
Failure ModesSeverity
ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Does not operate250.0%Category II2Does not operate1.48E-052
Degraded (Functional)125.0%Does not operate1Intermittent6.72E-061
Intermittent125.0%Intermittent1Degraded (Functional)0.00E+001
Grand Total4Category III1Grand Total2.15E-054
Does not operate1
Category IV1
Degraded (Functional)1
Grand Total4

Cat I and II

W31P4Q-20-R-0015
ATTACHMENT 0010c.16
TAB 3 of 4
Major End Item:Shelter
Parent LRU:E069-Media Converter-03 (ICE)
Component:MEDIA CONVERTOR, WIN-T A334
Mission Phase-Operational Mode:All Phases
FPMH:9.5583
t:72
Cr = ∑Cm =2.75E-04
Modified Cr =4.30E-05
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R
Failure Effect atFailure Detection MethodCompensating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
2204CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADoes not operateHardware failure or software defectLoss of functionLoss of WIN-T Red DataDegraded Mission due to loss of External Sensor DataN/AN/AN/AN/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.50009.56E-061.72E-041.72E-05
2205CONVERTS FIBER TO COPPER - FOR WIN-T RED DATAIntermittentHardware failure or software defectIntermittent continuityProbable Loss of WIN-T Red DataProbable Degraded Mission due to loss of External Sensor DataN/AN/AN/AN/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.25009.56E-068.60E-058.60E-06

E069 Data

W31P4Q-20-R-0015
ATTACHMENT 0010c.16
TAB 4 of 4
Major End Item:Shelter
Parent LRU:E069-Media Converter-03 (ICE)
Component:MEDIA CONVERTOR, WIN-T A334
Mission Phase-Operational Mode:All Phases
FPMH:0.7463
t:72
Cr = ∑Cm =2.15E-05
Modified Cr =3.36E-06
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R
Failure Effect atFailure Detection MethodCompensating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
2203CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADoes not operateHardware failure or software defectLoss of functionLoss of WIN-T Red DataDegraded Mission due to loss of External Sensor DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.050.50007.46E-071.34E-061.34E-06
2204CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADoes not operateHardware failure or software defectLoss of functionLoss of WIN-T Red DataDegraded Mission due to loss of External Sensor DataN/AN/AN/AN/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.50007.46E-071.34E-051.34E-06
2205CONVERTS FIBER TO COPPER - FOR WIN-T RED DATAIntermittentHardware failure or software defectIntermittent continuityProbable Loss of WIN-T Red DataProbable Degraded Mission due to loss of External Sensor DataN/AN/AN/AN/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.25007.46E-076.72E-066.72E-07
2206CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADegraded (Functional)Hardware failure or software defectLoss of noncritical functionLoss of noncritical functionLoss of noncritical functionN/AN/AN/AN/ATBDCategory IVEOCs are RedundantCategory IV0.000.000.25007.46E-070.00E+000.00E+00

Sheet1

File details come from the government source that posted it. Updated .