Attachment 0010a.10 – R016 thru R025 Media Converter Module-FMECA.xlsx

XLSX spreadsheet 40 KB Posted

Attached to
RFP for Integrated Battle Command System (IBCS) LRIP/FRP
Solicitation number
W31P4Q-20-R-0015
Issued by

About this file

This document contains a Request for Proposal (RFP) for the Integrated Battle Command System (IBCS) Low Rate Initial Production/Full Rate Production (LRIP/FRP) effort. The RFP seeks production of IBCS hardware end items in accordance with supplied Technical Data Packages and the Critical Item Development Specification. Engineering changes may be required for obsolescence, new capabilities, and export considerations. Questions are due by December 10, 2020 and the RFP is only open to contractors who met entrance criteria posted on SAM.gov and were approved by the IFMC Project Office. The Department of the Army Materiel Command Contracting Command at Redstone Arsenal is the issuing agency.

View the file

Other files

File Type Posted
Attachment 0019 - Section L - Instructions Conditions and Notices to Offerors - 7DEC2020.docx DOCX document
Attachment 0010a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 0010a.5 – R005 SCIM-FMECA.xlsx XLSX spreadsheet
Attachment 0013i - D-IBCS-0473_Adv_NetMgr.pdf PDF
Attachment 0010e.4 – E102d thru E111 Vid Extender-FMECA.xlsx XLSX spreadsheet
Attachment 0022a.1.j - PL-ALH-215333 00 S-280 CASS INSTA.pdf PDF
Attachment 0010d.10 – E157 KVM Switch 2 Shelter-FMECA.xlsx XLSX spreadsheet
Attachment 0004a - EOC Acceptance Test Procedures_FINAL.docx DOCX document
Attachment 0010h - SWFMEA Results.xlsx XLSX spreadsheet
Attachment 0010d.1 – E123 TMSS – ECU-FMECA.xlsx XLSX spreadsheet
Attachment 0005 - Software Installation Instructions.docx DOCX document
Attachment 0026 - Use of Existing Government-Furnished Property.xlsx XLSX spreadsheet
Attachment 0010a.6 – R006 TIMING UNIT-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Exhibit C- IBCS DSL - 24NOV2020.docx DOCX document
Attachment 0004d - Operator Procedures For IFMC GSIL.docx DOCX document
Attachment 0010c.11 – E061 Isolation Router Red-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.6 – E051 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 0018 - IBCS LRIP FRP IDIQ Pricing Template_29Oct2020 v.3.xlsx XLSX spreadsheet
Attachment 0013c - IBCS-A301-003 Vol II Instructor Guide_redacted.pdf PDF
Attachment 0010e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0016 - Example Cage Code and Cognizant DCMA DCAA Information.xlsx XLSX spreadsheet
Attachment 0022a.1.e - ALH-215333 00 S-280 CASS INSTALLA.pdf PDF
Attachment 0010c.15 – E068 Media Converter 02 – FMECA.xlsx XLSX spreadsheet
Attachment 0010b.4 – E013 ADSI Shelter – Misc Equip-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.10 – E060 Shelter Switch – 02-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.11 – E149 – Table 5 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.13 – E063 Isolation Router Black-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.15 – R033 Media Converter Module 12-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.5 – E029 KVM Switch 1 Shelter Stack-FMECA.xlsx XLSX spreadsheet
Attachment 0004c - ECT Acceptance Test Procedures_FINAL.DOCX DOCX document
Attachment 0010e.6 – E143 – ICE UPS-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.6 – E030 KVM Console-FMECA.xlsx XLSX spreadsheet
Attachment 0012 - Risk Management Plan.pdf PDF
Attachment 0013a -A293-004 ETM 60 Percent Draft_redacted.pdf PDF
Attachment 0022a.2 - PDRS Support information for integration task.pptx PPTX presentation
Attachment 0010c.16 – E069 Media Converter 03 - FMECA.xlsx XLSX spreadsheet
Attachment 0022a.1.f - EOC Shelter views.pptx PPTX presentation
Attachment 0001 - IBCS LRIP FRP Statement of Work - 24NOV2020.docx DOCX document
Attachment 0010a.2 – R002 BPU-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.4 – R004 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 0022a.1.g - PL-ALH-209032 00 CABLE ASSEMBLY C.pdf PDF
Attachment 0010b.7 – E031 R112 Shelter – Server Stack – 01-FEMCA.xlsx XLSX spreadsheet
Attachment 0004 - Acceptance Test Plan.docx DOCX document
Attachment 0006 - Obsolete Parts List.pdf PDF
Attachment 0010a.11 – R029 PFPU SSHD-1—FMECA.xlsx XLSX spreadsheet
Attachment 0011- Cost Report and Plan.pdf PDF
Attachment 0010d.3 – E150 S-280 PEV-FMECA.xlsx XLSX spreadsheet
Attachment 0013h - D-IBCS-0472_Adv_IDD_redacted.pdf PDF
Show 40 more

Latest 50 of 128 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pivot Table

W31P4Q-20-R-0015
ATTACHMENT 0010a.10
TAB 1 of 4
R016 thru R025 Media Converter Module
Row LabelsSum of CmCount of Failure Mode Description
Media Converter fails to process data2.69E-0410
Grand Total2.69E-0410

Prelim Analsis

PRELIMINARY ANALYSIS:Parent LRU:R016 thru R025 Media Converter Module (Indivdual)W31P4Q-20-R-0015
Component:Media Converter ModuleATTACHMENT 0010a.10
Mission Phase-Operational Mode:All PhasesTAB 2 of 4
Cr = ∑Cm =2.69E-04
Failure ModesCount of
Failure ModesSeverity
ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Media Converter fails to process data10100%Category II10Media Converter fails to process data2.69E-0410
Grand Total10Media Converter fails to process data10Grand Total2.69E-0410
Grand Total10

Cat I and Cat II

Parent LRU:R016 thru R025 Media Converter Module (Indivdual)W31P4Q-20-R-0015
Component:Media Converter ModuleATTACHMENT 0010a.10
Mission Phase-Operational Mode:All PhasesTAB 3 of 4
FPMH:1.540
t:72hr
Cr = ∑Cm =5.54E-04
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R
Failure Effect atFailure Detection MethodCompemsating Provisions
ID#Parent LRUComponentFunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
1176R016-Media Converter Module #1Media Converter Module in Slot #1Relay Media Converter in Slot-1Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data" signal from User Platform #1Relay cannot connect to "Data" interface for User Platform #1Loss of communication/control for User Platform #1N/AN/AOB-640-10VI-640-10 (Loss of IFCN Relay Communications with Platform-1 Data)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1177R017-Media Converter Module #2Media Converter Module in Slot #2Relay Media Converter in Slot-2Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Voice" signal from User Platform #1Relay cannot connect to "Voice" interface for User Platform #1Loss of communication/control for User Platform #1N/AN/AOB-640-10VI-640-11 (Loss of IFCN Relay Communications with Platform-1 Voice)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1178R018-Media Converter Module #3Media Converter Module in Slot #3Relay Media Converter in Slot-3Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #2Relay cannot connect to "Data-1" interface for User Platform #2Loss of communication/control for User Platform #2N/AN/AOB-640-10VI-640-12 (Loss of IFCN Relay Communications with Platform-2 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1179R019-Media Converter Module #4Media Converter Module in Slot #4Relay Media Converter in Slot-4Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-2" signal from User Platform #2Relay cannot connect to "Data-2" interface for User Platform #2Loss of communication/control for User Platform #2N/AN/AOB-640-10VI-640-13 (Loss of IFCN Relay Communications with Platform-2 Data-2)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1180R020-Media Converter Module #5Media Converter Module in Slot #5Relay Media Converter in Slot-5Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #3Relay cannot connect to "Data-1" interface for User Platform #3Loss of communication/control for User Platform #3N/AN/AOB-640-10VI-640-14 (Loss of IFCN Relay Communications with Platform-3 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1181R021-Media Converter Module #6Media Converter Module in Slot #6Relay Media Converter in Slot-6Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-2" signal from User Platform #3Relay cannot connect to "Data-2" interface for User Platform #3Loss of communication/control for User Platform #3N/AN/AOB-640-10VI-640-15 (Loss of IFCN Relay Communications with Platform-3 Data-2)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1182R022-Media Converter Module #7Media Converter Module in Slot #7Relay Media Converter in Slot-7Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #4Relay cannot connect to "Data-1" interface for User Platform #4Loss of communication/control for User Platform #4N/AN/AOB-640-10VI-640-16 (Loss of IFCN Relay Communications with Platform-4 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1183R023-Media Converter Module #8Media Converter Module in Slot #8Relay Media Converter in Slot-8Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-2" signal from User Platform #4Relay cannot connect to "Data-2" interface for User Platform #4Loss of communication/control for User Platform #4N/AN/AOB-640-10VI-640-17 (Loss of IFCN Relay Communications with Platform-4 Data-2)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1184R024-Media Converter Module #9Media Converter Module in Slot #9Relay Media Converter in Slot-9Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #5Relay cannot connect to "Data-1" interface for User Platform #5Loss of communication/control for User Platform #5N/AN/AOB-640-10VI-640-18 (Loss of IFCN Relay Communications with Platform-5 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06
1185R025-Media Converter Module #10Media Converter Module in Slot #10Relay Media Converter in Slot-10Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #6Relay cannot connect to "Data-1" interface for User Platform #6Loss of communication/control for User Platform #6N/AN/AOB-640-10VI-640-19 (Loss of IFCN Relay Communications with Platform-6 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.001.5398E-065.54E-055.54E-06

R016 - R025 Data

W31P4Q-20-R-0015
ATTACHMENT 0010a.10
Parent LRU:R016 thru R025 Media Converter Module (Indivdual)TAB 4 of 4
Component:Media Converter Module
Mission Phase-Operational Mode:All Phases
FPMH:0.746
t:72hr
Cr = ∑Cm =2.69E-04
Modified Cr =2.69E-05
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R
Failure Effect atFailure Detection MethodCompemsating Provisions
ID#Parent LRUComponentFunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
1176R016-Media Converter Module #1Media Converter Module in Slot #1Relay Media Converter in Slot-1Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data" signal from User Platform #1Relay cannot connect to "Data" interface for User Platform #1Loss of communication/control for User Platform #1N/AN/AOB-640-10VI-640-10 (Loss of IFCN Relay Communications with Platform-1 Data)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1177R017-Media Converter Module #2Media Converter Module in Slot #2Relay Media Converter in Slot-2Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Voice" signal from User Platform #1Relay cannot connect to "Voice" interface for User Platform #1Loss of communication/control for User Platform #1N/AN/AOB-640-10VI-640-11 (Loss of IFCN Relay Communications with Platform-1 Voice)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1178R018-Media Converter Module #3Media Converter Module in Slot #3Relay Media Converter in Slot-3Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #2Relay cannot connect to "Data-1" interface for User Platform #2Loss of communication/control for User Platform #2N/AN/AOB-640-10VI-640-12 (Loss of IFCN Relay Communications with Platform-2 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1179R019-Media Converter Module #4Media Converter Module in Slot #4Relay Media Converter in Slot-4Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-2" signal from User Platform #2Relay cannot connect to "Data-2" interface for User Platform #2Loss of communication/control for User Platform #2N/AN/AOB-640-10VI-640-13 (Loss of IFCN Relay Communications with Platform-2 Data-2)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1180R020-Media Converter Module #5Media Converter Module in Slot #5Relay Media Converter in Slot-5Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #3Relay cannot connect to "Data-1" interface for User Platform #3Loss of communication/control for User Platform #3N/AN/AOB-640-10VI-640-14 (Loss of IFCN Relay Communications with Platform-3 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1181R021-Media Converter Module #6Media Converter Module in Slot #6Relay Media Converter in Slot-6Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-2" signal from User Platform #3Relay cannot connect to "Data-2" interface for User Platform #3Loss of communication/control for User Platform #3N/AN/AOB-640-10VI-640-15 (Loss of IFCN Relay Communications with Platform-3 Data-2)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1182R022-Media Converter Module #7Media Converter Module in Slot #7Relay Media Converter in Slot-7Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #4Relay cannot connect to "Data-1" interface for User Platform #4Loss of communication/control for User Platform #4N/AN/AOB-640-10VI-640-16 (Loss of IFCN Relay Communications with Platform-4 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1183R023-Media Converter Module #8Media Converter Module in Slot #8Relay Media Converter in Slot-8Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-2" signal from User Platform #4Relay cannot connect to "Data-2" interface for User Platform #4Loss of communication/control for User Platform #4N/AN/AOB-640-10VI-640-17 (Loss of IFCN Relay Communications with Platform-4 Data-2)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1184R024-Media Converter Module #9Media Converter Module in Slot #9Relay Media Converter in Slot-9Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #5Relay cannot connect to "Data-1" interface for User Platform #5Loss of communication/control for User Platform #5N/AN/AOB-640-10VI-640-18 (Loss of IFCN Relay Communications with Platform-5 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06
1185R025-Media Converter Module #10Media Converter Module in Slot #10Relay Media Converter in Slot-10Media Converter fails to process dataHardware
FailureMedia Converter fails to process "Data-1" signal from User Platform #6Relay cannot connect to "Data-1" interface for User Platform #6Loss of communication/control for User Platform #6N/AN/AOB-640-10VI-640-19 (Loss of IFCN Relay Communications with Platform-6 Data-1)TBDCategory IIRelays are RedundantCategory III-2R0.500.051.007.4630E-072.69E-052.69E-06

Sheet1