Attachment 0010a.5 – R005 SCIM-FMECA.xlsx

XLSX spreadsheet 51 KB Posted

Attached to
RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
Solicitation number
W31P4Q-20-R-0015
Issued by
Department of the Army Materiel Command Contracting Command Redstone Arsenal

About this file

This document package includes an Excel spreadsheet containing failure modes and effects criticality analysis (FMECA) data as well as a request for proposal (RFP) for Integrated Battle Command System (IBCS) Low Rate Initial Production/Full Rate Production (LRIP/FRP).

The Excel spreadsheet provides FMECA data for the Status Coordinate Input Module (SCIM) component of IBCS. It lists potential failure modes, effects, criticality assessments, and severity classifications. Detection methods, compensating provisions, and safety impacts are also included. The RFP solicits proposals to produce IBCS hardware in accordance with supplied technical data packages and specifications. Questions are due by December 10, 2020 at 4pm Central Time. The RFP is only open to contractors who met entrance criteria through the Beta SAM portal and were approved by the Integrated Fires Mission Command Project Office within the Department of the Army Materiel Command Contracting Command at Redstone Arsenal.

View the file

Other files for this federal contract opportunity

Other files attached to RFP for Integrated Battle Command System (IBCS) LRIP/FRP, newest first.
File Type Posted
Attachment 0018 - IBCS LRIP FRP IDIQ Pricing Template_29Oct2020 v.3.xlsx XLSX spreadsheet
Attachment 0004 - Acceptance Test Plan.docx DOCX document
Attachment 0004c - ECT Acceptance Test Procedures_FINAL.DOCX DOCX document
Attachment 0006 - Obsolete Parts List.pdf PDF
Attachment 0010a.4 – R004 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.8 – R008 Media Converter Chassis-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.11 – R029 PFPU SSHD-1—FMECA.xlsx XLSX spreadsheet
Attachment 0010a.15 – R033 Media Converter Module 12-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.4 – E013 ADSI Shelter – Misc Equip-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.5 – E029 KVM Switch 1 Shelter Stack-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.7 – E031 R112 Shelter – Server Stack – 01-FEMCA.xlsx XLSX spreadsheet
Attachment 0010c.2 – E044 Firewall Black-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.5 – E050 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.10 – E060 Shelter Switch – 02-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.13 – E063 Isolation Router Black-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.15 – E068 Media Converter 02 – FMECA.xlsx XLSX spreadsheet
Attachment 0010d.3 – E150 S-280 PEV-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.1 – E067 – EtherNet Switch-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.7 – E145 – Table 1 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.11 – E149 – Table 5 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010f - IBCS - 243-003 HW FMECA Results redacted.docx DOCX document
Attachment 0011- Cost Report and Plan.pdf PDF
Attachment 0013d - IBCS-A301-003 Vol III Program of Instruction_redacted.pdf PDF
Attachment 0013h - D-IBCS-0472_Adv_IDD_redacted.pdf PDF
Attachment 0021 - Delivery Order 0001 Statement of Work - 24 Nov 2020.docx DOCX document
Attachment 0022 - Preliminary Class I ECP Candidates.v2.docx DOCX document
Attachment 0022a.1.c - ALH-211130 00 CABLE ASSEMBLY CASS.pdf PDF
Attachment 0022a.1.g - PL-ALH-209032 00 CABLE ASSEMBLY C.pdf PDF
Attachment 0022c - IFCN Relay NEA Rev 4.docx DOCX document
Attachment 0030 - POAMImportTemplate RM Standard.xlsm.xlsx XLSX spreadsheet
EXHIBIT A - CONTRACT DATA ITEM REQUIREMENTS LIST (CDRL) - 24NOV2020.pdf PDF
Exhibit C- IBCS DSL - 24NOV2020.docx DOCX document
Attachment 0002 - AIAMD System of Systems (SoS)(MIS-PRF-56500).pdf PDF
Attachment 0004b - Relay Acceptance Test Procedures_FINAL.docx DOCX document
Attachment 0004d - Operator Procedures For IFMC GSIL.docx DOCX document
Attachment 0005 - Software Installation Instructions.docx DOCX document
Attachment 0008 - AIAMD IUID Plan Appendix A - IUID Candidates List Data Items.pdf PDF
Attachment 0009 - R and M Prediction Report.docx DOCX document
Attachment 0010a.3 – R003 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.7 – R007 Relay Network Switch-Parvus Switch-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 0010c.3 – E048 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.8 – E053 Shelter Time Server-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.9 – E059 Shelter Switch – 01-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.8 – E153 RS112 Server -07 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0012 - Risk Management Plan.pdf PDF
Show all 50

RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pivot Table

W31P4Q-20-R-0015
ATTACHMENT 0010a.5
TAB 1 OF 4
R005-SCIM (Status Coordinate Input Module)
Row LabelsCount of Failure Mode Description
Category IInternal Failure70.2
Internal Failure3Shorted70.2
Open4Open70.2
Shorted3Improper Display50.1428571429
Workmanship1Intermittent30.0857142857
Improper Display2Jacket rupture20.0571428571
Category IIIOverheat20.0571428571
Contamination1Contamination10.0285714286
Intermittent3Workmanship10.0285714286
Internal Failure2Grand Total351
Jacket rupture2
Open3
Overheat2
Shorted4
Improper Display3
Category IV
Internal Failure2
Grand Total35

Prelim Analysis

W31P4Q-20-R-0015
ATTACHMENT 0010a.5
Parent LRU:R005-SCIM (Status Coordinate Input Module)TAB 2 OF 4
Component:Status Coordinate Input Module (SCIM)
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =2.08E-04
Failure ModesCount of
Failure ModesSeverity
ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Internal Failure720.00%Category I13Open7.05E-057
Shorted720.00%Internal Failure3Shorted5.44E-057
Open720.00%Open4Internal Failure5.27E-057
Improper Display514.29%Shorted3Improper Display2.61E-055
Intermittent38.57%Workmanship1Workmanship2.43E-061
Jacket rupture25.71%Improper Display2Intermittent1.09E-063
Overheat25.71%Category III20Overheat4.85E-072
Contamination12.86%Contamination1Jacket rupture4.85E-072
Workmanship12.86%Intermittent3Contamination1.21E-071
Grand Total35Internal Failure2Grand Total2.08E-0435
Jacket rupture2
Open3
Overheat2
Shorted4
Improper Display3
Category IV2
Internal Failure2
Grand Total35

Cat I and II

Parent LRU:R005-SCIM (Status Coordinate Input Module)W31P4Q-20-R-0015
Component:Status Coordinate Input Module (SCIM)ATTACHMENT 0010a.5
Mission Phase-Operational Mode:All PhasesTAB 3 OF 4
FPMH:1.1797
t:72hr
Cr = ∑Cm =1.97E-04
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-1R
Failure Effect atFailure Detection MethodCompemsating Provisions
FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
Communications/ Logic Power Connector (J1) – RS232 (pins 1, 2, 6)OpenHardware failureNo throughputSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
Communications/ Logic Power Connector (J1) – RS232 (pins 1, 2, 6)ShortedHardware failureData connection shorted resulting in loss of communicationSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
Communications/ Logic Power Connector (J1) – 5VDC (pins 3, 4, 5)OpenHardware failureNo throughputSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
LCDWorkmanshipManufacturing defectLoss of functionSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.02861.18E-062.43E-061.21E-07
LCDImproper DisplayHardware failureLoss of functionSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.14291.18E-061.21E-056.07E-07
LCDImproper DisplayHardware failureLoss of functionSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.14291.18E-061.21E-056.07E-07
Central ProcessorOpenHardware failureNo throughputSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
Central ProcessorInternal FailureHardware failureLoss of functionSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
Rotary Knob (x3)Internal FailureHardware failureSignal is neither driven to a logical high nor low level. Similar to an open circuit.SCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-72 (Relay SCIM Control Panel Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
Rotary Knob (x3)ShortedHardware failureSignal failed high or low. Inaccurate/ uncontrollable knob operation.SCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-72 (Relay SCIM Control Panel Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
RS232 Level TranslatorOpenHardware failureCentral Processor cannot send or receive information to external connectorsSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
RS232 Level TranslatorShortedHardware failureData connection shorted resulting in loss of communicationSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
Location InputInternal FailureHardware failure or software defectComponent inoperativeLoss of redundancy; for total loss of function, impending loss of network communicationLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-72 (Relay SCIM Control Panel Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07

R005 Data

W31P4Q-20-R-0015
Parent LRU:R005-SCIM (Status Coordinate Input Module)ATTACHMENT 0010a.5
Component:Status Coordinate Input Module (SCIM)TAB 4 OF 4
Mission Phase-Operational Mode:All Phases
FPMH:1.1797
t:72hr
Cr = ∑Cm =2.08E-04
Modified Cr =2.15E-05
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-1R
Failure Effect atFailure Detection MethodCompemsating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
461Communications/ Logic Power Connector (J1) – RS232 (pins 1, 2, 6)OpenHardware failureNo throughputSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
462Communications/ Logic Power Connector (J1) – RS232 (pins 1, 2, 6)IntermittentHardware failureIntermittent continuitySCIM possibly inoperablePossible loss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIIRelays are RedundantCategory III0.050.050.08571.18E-063.64E-073.64E-07
463Communications/ Logic Power Connector (J1) – RS232 (pins 1, 2, 6)ShortedHardware failureData connection shorted resulting in loss of communicationSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
464Communications/ Logic Power Connector (J1) – 5VDC (pins 3, 4, 5)OpenHardware failureNo throughputSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
465Communications/ Logic Power Connector (J1) – 5VDC (pins 3, 4, 5)IntermittentHardware failureIntermittent continuitySCIM possibly inoperablePossible loss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIIRelays are RedundantCategory III0.050.050.08571.18E-063.64E-073.64E-07
466Communications/ Logic Power Connector (J1) – 5VDC (pins 3, 4, 5)ShortedHardware failurePower shorted resulting in possible tripping of IGRM circuit breakerIGRM possibly cannot provide data to BPUPossible impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIIRelays are RedundantCategory III0.050.050.20001.18E-068.49E-078.49E-07
467Heater Power Connector (J2) (pins 1, 3)OpenHardware failureNo throughputIn the event of very low temperatures, possibly unable to operate SCIMPossible loss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIIRelays are RedundantCategory III0.050.050.20001.18E-068.49E-078.49E-07
468Heater Power Connector (J2) (pins 1, 3)IntermittentHardware failureIntermittent continuityIn the event of very low temperatures, possibly unable to operate SCIMPossible loss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIIRelays are RedundantCategory III0.050.050.08571.18E-063.64E-073.64E-07
469Heater Power Connector (J2) (pins 1, 3)ShortedHardware failurePower shorted resulting in possible damage to components or tripping of SCIM Heater circuit breaker.In the event of very low temperatures, possibly unable to operate SCIMPossible loss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-70 (Relay SCIM Circuit Breaker Tripped)TBDCategory IIIRelays are RedundantCategory III0.050.050.20001.18E-068.49E-078.49E-07
470Heater Power Connector (J2) – Unused pin 2Internal FailureHardware failureComponent inoperativeNo impact, function not used for this applicationNo impactN/AN/AN/AN/ATBDCategory IVRelays are RedundantCategory IV0.000.000.20001.18E-060.00E+000.00E+00
471LCDImproper DisplayHardware failureOperator may not be able to interpret SCIM messages or provide correct inputs.SCIM possibly inoperablePossible loss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIIRelays are RedundantCategory III0.050.050.14291.18E-066.07E-076.07E-07
472LCDImproper DisplayHardware failureOperator may not be able to interpret SCIM messages or provide correct inputs.SCIM possibly inoperablePossible loss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIIRelays are RedundantCategory III0.050.050.14291.18E-066.07E-076.07E-07
473LCDWorkmanshipManufacturing defectLoss of functionSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.02861.18E-062.43E-061.21E-07
474LCDImproper DisplayHardware failureOperator may not be able to interpret SCIM messages or provide correct inputs.SCIM possibly inoperablePossible loss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIIRelays are RedundantCategory III0.050.050.14291.18E-066.07E-076.07E-07
475LCDImproper DisplayHardware failureLoss of functionSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.14291.18E-061.21E-056.07E-07
476LCDImproper DisplayHardware failureLoss of functionSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.14291.18E-061.21E-056.07E-07
477Central ProcessorContaminationFODPossible short circuitSCIM possibly inoperablePossible loss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIIRelays are RedundantCategory III0.050.050.02861.18E-061.21E-071.21E-07
478Central ProcessorOpenHardware failureNo throughputSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
479Central ProcessorInternal FailureHardware failureLoss of functionSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
480Central ProcessorInternal FailureHardware failureSCIM no longer meets performance specifications (e.g., leakage current). Possible trip of IGRM circuit breaker or SCIM Heater circuit breaker.IGRM possibly cannot provide data to BPUPossible impending loss of network communicationN/AN/AOB-625-70VI-625-70 (Relay SCIM Circuit Breaker Tripped)TBDCategory IIIRelays are RedundantCategory III0.050.050.20001.18E-068.49E-078.49E-07
481Unused Pins (x28)Internal FailureHardware failureComponent inoperativeNo impact, function not used for this applicationNo impactN/AN/AN/AN/ATBDCategory IVRelays are RedundantCategory IV0.000.000.20001.18E-060.00E+000.00E+00
482Rotary Knob (x3)Internal FailureHardware failureSignal is neither driven to a logical high nor low level. Similar to an open circuit.SCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-72 (Relay SCIM Control Panel Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
483Rotary Knob (x3)ShortedHardware failureSignal failed high or low. Inaccurate/ uncontrollable knob operation.SCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-72 (Relay SCIM Control Panel Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
484Display HeaterOpenHardware failureNo throughputIn the event of very low temperatures, possibly unable to operate SCIMPossible loss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIIRelays are RedundantCategory III0.050.050.20001.18E-068.49E-078.49E-07
485Display HeaterShortedHardware failurePower shorted resulting in possible damage to components or tripping of SCIM Heater circuit breaker.In the event of very low temperatures, possibly unable to operate SCIMPossible loss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-70 (Relay SCIM Circuit Breaker Tripped)TBDCategory IIIRelays are RedundantCategory III0.050.050.20001.18E-068.49E-078.49E-07
486Display HeaterOverheatHardware failureIncreased cooling requiredPossible damage to components due to overheatPossible loss of network communicationN/AN/AN/AN/ATBDCategory IIIRelays are RedundantCategory III0.050.050.05711.18E-062.43E-072.43E-07
487Display HeaterJacket ruptureHardware failureHeating elements exposed creating an ignition source.If a flammable material is present, possible fire hazardIf a flammable material is present, possible fire hazardN/AN/AN/AN/ATBDCategory IIIRelays are RedundantCategory III0.050.050.05711.18E-062.43E-072.43E-07
488PCB HeaterOpenHardware failureNo throughputIn the event of very low temperatures, possibly unable to operate SCIMPossible loss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIIRelays are RedundantCategory III0.050.050.20001.18E-068.49E-078.49E-07
489PCB HeaterShortedHardware failurePower shorted resulting in possible damage to components or tripping of SCIM Heater circuit breaker.In the event of very low temperatures, possibly unable to operate SCIMPossible loss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-70 (Relay SCIM Circuit Breaker Tripped)TBDCategory IIIRelays are RedundantCategory III0.050.050.20001.18E-068.49E-078.49E-07
490PCB HeaterOverheatHardware failureIncreased cooling requiredPossible damage to components due to overheatPossible loss of network communicationN/AN/AN/AN/ATBDCategory IIIRelays are RedundantCategory III0.050.050.05711.18E-062.43E-072.43E-07
491PCB HeaterJacket ruptureHardware failureHeating elements exposed creating an ignition source.If a flammable material is present, possible fire hazardIf a flammable material is present, possible fire hazardN/AN/AN/AN/ATBDCategory IIIRelays are RedundantCategory III0.050.050.05711.18E-062.43E-072.43E-07
492RS232 Level TranslatorOpenHardware failureCentral Processor cannot send or receive information to external connectorsSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
493RS232 Level TranslatorInternal FailureHardware failureCentral Processor possibly cannot send or receive information to external connectorsSCIM possibly inoperablePossible loss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IIIRelays are RedundantCategory III0.050.050.20001.18E-068.49E-078.49E-07
494RS232 Level TranslatorShortedHardware failureData connection shorted resulting in loss of communicationSCIM inoperableLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-71 (Relay SCIM Display Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07
495Location InputInternal FailureHardware failure or software defectComponent inoperativeLoss of redundancy; for total loss of function, impending loss of network communicationLoss of redundancy; for total loss of function, impending loss of network communicationN/AN/AOB-625-70VI-625-72 (Relay SCIM Control Panel Failure)TBDCategory IRelays are RedundantCategory III-1R1.000.050.20001.18E-061.70E-058.49E-07

Sheet1

File details come from the government source that posted it. Updated .