This document package includes an Excel spreadsheet containing failure modes and effects criticality analysis (FMECA) data as well as a request for proposal (RFP) for Integrated Battle Command System (IBCS) Low Rate Initial Production/Full Rate Production (LRIP/FRP).
The Excel spreadsheet provides FMECA data for the Status Coordinate Input Module (SCIM) component of IBCS. It lists potential failure modes, effects, criticality assessments, and severity classifications. Detection methods, compensating provisions, and safety impacts are also included. The RFP solicits proposals to produce IBCS hardware in accordance with supplied technical data packages and specifications. Questions are due by December 10, 2020 at 4pm Central Time. The RFP is only open to contractors who met entrance criteria through the Beta SAM portal and were approved by the Integrated Fires Mission Command Project Office within the Department of the Army Materiel Command Contracting Command at Redstone Arsenal.
View the file
Other files for this federal contract opportunity
Show all 50
RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pivot Table
| W31P4Q-20-R-0015 | ||||
| ATTACHMENT 0010a.5 | ||||
| TAB 1 OF 4 | ||||
| R005-SCIM (Status Coordinate Input Module) | ||||
| Row Labels | Count of Failure Mode Description | |||
| Category I | Internal Failure | 7 | 0.2 | |
| Internal Failure | 3 | Shorted | 7 | 0.2 |
| Open | 4 | Open | 7 | 0.2 |
| Shorted | 3 | Improper Display | 5 | 0.1428571429 |
| Workmanship | 1 | Intermittent | 3 | 0.0857142857 |
| Improper Display | 2 | Jacket rupture | 2 | 0.0571428571 |
| Category III | Overheat | 2 | 0.0571428571 | |
| Contamination | 1 | Contamination | 1 | 0.0285714286 |
| Intermittent | 3 | Workmanship | 1 | 0.0285714286 |
| Internal Failure | 2 | Grand Total | 35 | 1 |
| Jacket rupture | 2 | |||
| Open | 3 | |||
| Overheat | 2 | |||
| Shorted | 4 | |||
| Improper Display | 3 | |||
| Category IV | ||||
| Internal Failure | 2 | |||
| Grand Total | 35 |
Prelim Analysis
| W31P4Q-20-R-0015 | |||||
| ATTACHMENT 0010a.5 | |||||
| Parent LRU: | R005-SCIM (Status Coordinate Input Module) | TAB 2 OF 4 | |||
| Component: | Status Coordinate Input Module (SCIM) | ||||
| Mission Phase-Operational Mode: | All Phases | ||||
| Cr = ∑Cm = | 2.08E-04 | ||||
| Failure Modes | Count of | ||||
| Failure Modes | Severity | ||||
| Classifications | Count of |
Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes
| Internal Failure | 7 | 20.00% | Category I | 13 | Open | 7.05E-05 | 7 |
| Shorted | 7 | 20.00% | Internal Failure | 3 | Shorted | 5.44E-05 | 7 |
| Open | 7 | 20.00% | Open | 4 | Internal Failure | 5.27E-05 | 7 |
| Improper Display | 5 | 14.29% | Shorted | 3 | Improper Display | 2.61E-05 | 5 |
| Intermittent | 3 | 8.57% | Workmanship | 1 | Workmanship | 2.43E-06 | 1 |
| Jacket rupture | 2 | 5.71% | Improper Display | 2 | Intermittent | 1.09E-06 | 3 |
| Overheat | 2 | 5.71% | Category III | 20 | Overheat | 4.85E-07 | 2 |
| Contamination | 1 | 2.86% | Contamination | 1 | Jacket rupture | 4.85E-07 | 2 |
| Workmanship | 1 | 2.86% | Intermittent | 3 | Contamination | 1.21E-07 | 1 |
| Grand Total | 35 | Internal Failure | 2 | Grand Total | 2.08E-04 | 35 | |
| Jacket rupture | 2 | ||||||
| Open | 3 | ||||||
| Overheat | 2 | ||||||
| Shorted | 4 | ||||||
| Improper Display | 3 | ||||||
| Category IV | 2 | ||||||
| Internal Failure | 2 | ||||||
| Grand Total | 35 |
Cat I and II
| Parent LRU: | R005-SCIM (Status Coordinate Input Module) | W31P4Q-20-R-0015 | ||||||||||||||||||
| Component: | Status Coordinate Input Module (SCIM) | ATTACHMENT 0010a.5 | ||||||||||||||||||
| Mission Phase-Operational Mode: | All Phases | TAB 3 OF 4 | ||||||||||||||||||
| FPMH: | 1.1797 | |||||||||||||||||||
| t: | 72 | hr | ||||||||||||||||||
| Cr = ∑Cm = | 1.97E-04 | |||||||||||||||||||
| Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-1R | ||||||||||||||||||||
| Failure Effect at | Failure Detection Method | Compemsating Provisions | ||||||||||||||||||
| Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety | ||||||||||||||
| Consideration | Safety | |||||||||||||||||||
| Impact | Operator Observation | Visual Indicator | C-Bit | |||||||||||||||||
| Capabilities | Severity | |||||||||||||||||||
| Classification | Alternate Design | |||||||||||||||||||
| Modifications | Modified Severity | |||||||||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | ||||||||||||||
| Communications/ Logic Power Connector (J1) – RS232 (pins 1, 2, 6) | Open | Hardware failure | No throughput | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| Communications/ Logic Power Connector (J1) – RS232 (pins 1, 2, 6) | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| Communications/ Logic Power Connector (J1) – 5VDC (pins 3, 4, 5) | Open | Hardware failure | No throughput | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| LCD | Workmanship | Manufacturing defect | Loss of function | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.0286 | 1.18E-06 | 2.43E-06 | 1.21E-07 | |
| LCD | Improper Display | Hardware failure | Loss of function | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.1429 | 1.18E-06 | 1.21E-05 | 6.07E-07 | |
| LCD | Improper Display | Hardware failure | Loss of function | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.1429 | 1.18E-06 | 1.21E-05 | 6.07E-07 | |
| Central Processor | Open | Hardware failure | No throughput | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| Central Processor | Internal Failure | Hardware failure | Loss of function | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| Rotary Knob (x3) | Internal Failure | Hardware failure | Signal is neither driven to a logical high nor low level. Similar to an open circuit. | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-72 (Relay SCIM Control Panel Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| Rotary Knob (x3) | Shorted | Hardware failure | Signal failed high or low. Inaccurate/ uncontrollable knob operation. | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-72 (Relay SCIM Control Panel Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| RS232 Level Translator | Open | Hardware failure | Central Processor cannot send or receive information to external connectors | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| RS232 Level Translator | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| Location Input | Internal Failure | Hardware failure or software defect | Component inoperative | Loss of redundancy; for total loss of function, impending loss of network communication | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-72 (Relay SCIM Control Panel Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 |
R005 Data
| W31P4Q-20-R-0015 | |||||||||||||||||||||
| Parent LRU: | R005-SCIM (Status Coordinate Input Module) | ATTACHMENT 0010a.5 | |||||||||||||||||||
| Component: | Status Coordinate Input Module (SCIM) | TAB 4 OF 4 | |||||||||||||||||||
| Mission Phase-Operational Mode: | All Phases | ||||||||||||||||||||
| FPMH: | 1.1797 | ||||||||||||||||||||
| t: | 72 | hr | |||||||||||||||||||
| Cr = ∑Cm = | 2.08E-04 | ||||||||||||||||||||
| Modified Cr = | 2.15E-05 | ||||||||||||||||||||
| Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-1R | |||||||||||||||||||||
| Failure Effect at | Failure Detection Method | Compemsating Provisions | |||||||||||||||||||
| ID# | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety | ||||||||||||||
| Consideration | Safety | ||||||||||||||||||||
| Impact | Operator Observation | Visual Indicator | C-Bit | ||||||||||||||||||
| Capabilities | Severity | ||||||||||||||||||||
| Classification | Alternate Design | ||||||||||||||||||||
| Modifications | Modified Severity | ||||||||||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | |||||||||||||||
| 461 | Communications/ Logic Power Connector (J1) – RS232 (pins 1, 2, 6) | Open | Hardware failure | No throughput | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| 462 | Communications/ Logic Power Connector (J1) – RS232 (pins 1, 2, 6) | Intermittent | Hardware failure | Intermittent continuity | SCIM possibly inoperable | Possible loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.0857 | 1.18E-06 | 3.64E-07 | 3.64E-07 | |
| 463 | Communications/ Logic Power Connector (J1) – RS232 (pins 1, 2, 6) | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| 464 | Communications/ Logic Power Connector (J1) – 5VDC (pins 3, 4, 5) | Open | Hardware failure | No throughput | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| 465 | Communications/ Logic Power Connector (J1) – 5VDC (pins 3, 4, 5) | Intermittent | Hardware failure | Intermittent continuity | SCIM possibly inoperable | Possible loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.0857 | 1.18E-06 | 3.64E-07 | 3.64E-07 | |
| 466 | Communications/ Logic Power Connector (J1) – 5VDC (pins 3, 4, 5) | Shorted | Hardware failure | Power shorted resulting in possible tripping of IGRM circuit breaker | IGRM possibly cannot provide data to BPU | Possible impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.2000 | 1.18E-06 | 8.49E-07 | 8.49E-07 | |
| 467 | Heater Power Connector (J2) (pins 1, 3) | Open | Hardware failure | No throughput | In the event of very low temperatures, possibly unable to operate SCIM | Possible loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.2000 | 1.18E-06 | 8.49E-07 | 8.49E-07 | |
| 468 | Heater Power Connector (J2) (pins 1, 3) | Intermittent | Hardware failure | Intermittent continuity | In the event of very low temperatures, possibly unable to operate SCIM | Possible loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.0857 | 1.18E-06 | 3.64E-07 | 3.64E-07 | |
| 469 | Heater Power Connector (J2) (pins 1, 3) | Shorted | Hardware failure | Power shorted resulting in possible damage to components or tripping of SCIM Heater circuit breaker. | In the event of very low temperatures, possibly unable to operate SCIM | Possible loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-70 (Relay SCIM Circuit Breaker Tripped) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.2000 | 1.18E-06 | 8.49E-07 | 8.49E-07 | |
| 470 | Heater Power Connector (J2) – Unused pin 2 | Internal Failure | Hardware failure | Component inoperative | No impact, function not used for this application | No impact | N/A | N/A | N/A | N/A | TBD | Category IV | Relays are Redundant | Category IV | 0.00 | 0.00 | 0.2000 | 1.18E-06 | 0.00E+00 | 0.00E+00 | |
| 471 | LCD | Improper Display | Hardware failure | Operator may not be able to interpret SCIM messages or provide correct inputs. | SCIM possibly inoperable | Possible loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.1429 | 1.18E-06 | 6.07E-07 | 6.07E-07 | |
| 472 | LCD | Improper Display | Hardware failure | Operator may not be able to interpret SCIM messages or provide correct inputs. | SCIM possibly inoperable | Possible loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.1429 | 1.18E-06 | 6.07E-07 | 6.07E-07 | |
| 473 | LCD | Workmanship | Manufacturing defect | Loss of function | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.0286 | 1.18E-06 | 2.43E-06 | 1.21E-07 | |
| 474 | LCD | Improper Display | Hardware failure | Operator may not be able to interpret SCIM messages or provide correct inputs. | SCIM possibly inoperable | Possible loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.1429 | 1.18E-06 | 6.07E-07 | 6.07E-07 | |
| 475 | LCD | Improper Display | Hardware failure | Loss of function | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.1429 | 1.18E-06 | 1.21E-05 | 6.07E-07 | |
| 476 | LCD | Improper Display | Hardware failure | Loss of function | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.1429 | 1.18E-06 | 1.21E-05 | 6.07E-07 | |
| 477 | Central Processor | Contamination | FOD | Possible short circuit | SCIM possibly inoperable | Possible loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.0286 | 1.18E-06 | 1.21E-07 | 1.21E-07 | |
| 478 | Central Processor | Open | Hardware failure | No throughput | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| 479 | Central Processor | Internal Failure | Hardware failure | Loss of function | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| 480 | Central Processor | Internal Failure | Hardware failure | SCIM no longer meets performance specifications (e.g., leakage current). Possible trip of IGRM circuit breaker or SCIM Heater circuit breaker. | IGRM possibly cannot provide data to BPU | Possible impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-70 (Relay SCIM Circuit Breaker Tripped) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.2000 | 1.18E-06 | 8.49E-07 | 8.49E-07 | |
| 481 | Unused Pins (x28) | Internal Failure | Hardware failure | Component inoperative | No impact, function not used for this application | No impact | N/A | N/A | N/A | N/A | TBD | Category IV | Relays are Redundant | Category IV | 0.00 | 0.00 | 0.2000 | 1.18E-06 | 0.00E+00 | 0.00E+00 | |
| 482 | Rotary Knob (x3) | Internal Failure | Hardware failure | Signal is neither driven to a logical high nor low level. Similar to an open circuit. | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-72 (Relay SCIM Control Panel Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| 483 | Rotary Knob (x3) | Shorted | Hardware failure | Signal failed high or low. Inaccurate/ uncontrollable knob operation. | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-72 (Relay SCIM Control Panel Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| 484 | Display Heater | Open | Hardware failure | No throughput | In the event of very low temperatures, possibly unable to operate SCIM | Possible loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.2000 | 1.18E-06 | 8.49E-07 | 8.49E-07 | |
| 485 | Display Heater | Shorted | Hardware failure | Power shorted resulting in possible damage to components or tripping of SCIM Heater circuit breaker. | In the event of very low temperatures, possibly unable to operate SCIM | Possible loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-70 (Relay SCIM Circuit Breaker Tripped) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.2000 | 1.18E-06 | 8.49E-07 | 8.49E-07 | |
| 486 | Display Heater | Overheat | Hardware failure | Increased cooling required | Possible damage to components due to overheat | Possible loss of network communication | N/A | N/A | N/A | N/A | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.0571 | 1.18E-06 | 2.43E-07 | 2.43E-07 | |
| 487 | Display Heater | Jacket rupture | Hardware failure | Heating elements exposed creating an ignition source. | If a flammable material is present, possible fire hazard | If a flammable material is present, possible fire hazard | N/A | N/A | N/A | N/A | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.0571 | 1.18E-06 | 2.43E-07 | 2.43E-07 | |
| 488 | PCB Heater | Open | Hardware failure | No throughput | In the event of very low temperatures, possibly unable to operate SCIM | Possible loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.2000 | 1.18E-06 | 8.49E-07 | 8.49E-07 | |
| 489 | PCB Heater | Shorted | Hardware failure | Power shorted resulting in possible damage to components or tripping of SCIM Heater circuit breaker. | In the event of very low temperatures, possibly unable to operate SCIM | Possible loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-70 (Relay SCIM Circuit Breaker Tripped) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.2000 | 1.18E-06 | 8.49E-07 | 8.49E-07 | |
| 490 | PCB Heater | Overheat | Hardware failure | Increased cooling required | Possible damage to components due to overheat | Possible loss of network communication | N/A | N/A | N/A | N/A | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.0571 | 1.18E-06 | 2.43E-07 | 2.43E-07 | |
| 491 | PCB Heater | Jacket rupture | Hardware failure | Heating elements exposed creating an ignition source. | If a flammable material is present, possible fire hazard | If a flammable material is present, possible fire hazard | N/A | N/A | N/A | N/A | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.0571 | 1.18E-06 | 2.43E-07 | 2.43E-07 | |
| 492 | RS232 Level Translator | Open | Hardware failure | Central Processor cannot send or receive information to external connectors | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| 493 | RS232 Level Translator | Internal Failure | Hardware failure | Central Processor possibly cannot send or receive information to external connectors | SCIM possibly inoperable | Possible loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category III | Relays are Redundant | Category III | 0.05 | 0.05 | 0.2000 | 1.18E-06 | 8.49E-07 | 8.49E-07 | |
| 494 | RS232 Level Translator | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | SCIM inoperable | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 | |
| 495 | Location Input | Internal Failure | Hardware failure or software defect | Component inoperative | Loss of redundancy; for total loss of function, impending loss of network communication | Loss of redundancy; for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-72 (Relay SCIM Control Panel Failure) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.18E-06 | 1.70E-05 | 8.49E-07 |