This document contains a federal contract opportunity solicitation for the Integrated Battle Command System (IBCS) Low Rate Initial Production/Full Rate Production hardware segment. The Army Materiel Command Contracting Command at Redstone Arsenal is soliciting proposals to produce IBCS hardware end items according to supplied technical data packages and specifications. In addition to hardware production, the contract requires maintaining approved software and firmware updates, cybersecurity, and authority to operate on existing hardware. The solicitation number is W31P4Q-20-R-0015. Engineering changes may also be required for obsolescence, new capabilities, and export considerations. Questions regarding this opportunity were due by December 10, 2020 at 4:00 PM Central Standard Time. This opportunity is only for contractors who met entrance criteria posted on SAM.gov and were approved by the Integrated Fires Mission Command Project Office.
View the file
Other files for this federal contract opportunity
Show all 50
RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| W31P4Q-20-R-0015 | ||
| ATTACHMENT 0010a.4 | ||
| TAB 1 Of 4 | ||
| Row Labels | Sum of Cm | Count of Failure Mode Description |
| Opened | 1.24E-02 | 40 |
| Shorted | 9.84E-03 | 34 |
| Intermittent operation | 8.03E-03 | 47 |
| Failure to Operate (Timing) | 1.09E-03 | 10 |
| Loss of output or failure during operations | 1.09E-03 | 10 |
| Faulty Component | 3.78E-04 | 6 |
| Failed | 2.34E-04 | 13 |
| Degraded output or operational capability | 2.18E-04 | 9 |
| Premature Operation (Timing) | 1.05E-04 | 9 |
| Premature Operation (Zeroize) | 8.09E-05 | 3 |
| Failure to receive/send data within 10 minutes of BPU power-up | 7.19E-05 | 2 |
| Workmanship | 5.66E-05 | 3 |
| Failure to switch Timing Sources | 3.60E-05 | 2 |
| Failure to Cease Operation (Timing) | 2.16E-05 | 8 |
| Premature Operation (Location Source) | 8.99E-06 | 1 |
| Faulty Output | 8.99E-06 | 1 |
| Loose | 8.09E-06 | 3 |
| Grand Total | 3.37E-02 | 201 |
Prelim Analysis
| Parent LRU: | R004-IGRM | ||||
| Component: | Chassis Assembly | ||||
| IGRM GPS Receiver Board | |||||
| IGRM Processor Board | |||||
| IGRM Power Supply Board | W31P4Q-20-R-0015 | ||||
| Mission Phase-Operational Mode: | All Phases | ATTACHMENT 0010a.4 | |||
| Cr = ∑Cm = | 8.09E-06 | TAB 2 of 4 | |||
| Failure Modes | Count of | ||||
| Failure Modes | Severity | ||||
| Classifications | Count of |
Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes
| Intermittent operation | 47 | 23.38% | Category I | 11 | Opened | 1.24E-02 | 40 |
| Opened | 40 | 19.90% | Failure to Operate (Timing) | 3 | Shorted | 9.84E-03 | 34 |
| Shorted | 34 | 16.92% | Loss of output or failure during operations | 3 | Intermittent operation | 8.03E-03 | 47 |
| Failed | 13 | 6.47% | Failure to receive/send data ≤ 10 min. of BPU power-up | 2 | Failure to Operate (Timing) | 1.09E-03 | 10 |
| Failure to Operate (Timing) | 10 | 4.98% | Opened | 1 | Loss of output or failure during operations | 1.09E-03 | 10 |
| Loss of output or failure during operations | 10 | 4.98% | Faulty Component | 1 | Faulty Component | 3.78E-04 | 6 |
| Premature Operation (Timing) | 9 | 4.48% | Shorted | 1 | Failed | 2.34E-04 | 13 |
| Degraded output or operational capability | 9 | 4.48% | Category II | 35 | Degraded output or operational capability | 2.18E-04 | 9 |
| Failure to Cease Operation (Timing) | 8 | 3.98% | Opened | 15 | Premature Operation (Timing) | 1.05E-04 | 9 |
| Faulty Component | 6 | 2.99% | Shorted | 9 | Premature Operation (Zeroize) | 8.09E-05 | 3 |
| Loose | 3 | 1.49% | Faulty Component | 3 | Failure to receive/send data ≤ 10 min of BPU power-up | 7.19E-05 | 2 |
| Workmanship | 3 | 1.49% | Failure to Operate (Timing) | 2 | Workmanship | 5.66E-05 | 3 |
| Premature Operation (Zeroize) | 3 | 1.49% | Failed | 2 | Failure to switch Timing Sources | 3.60E-05 | 2 |
| Failure to receive/send data ≤ 10 min. of BPU power-up | 2 | 1.00% | Loss of output or failure during operations | 2 | Failure to Cease Operation (Timing) | 2.16E-05 | 8 |
| Failure to switch Timing Sources | 2 | 1.00% | Premature Operation (Timing) | 1 | Premature Operation (Location Source) | 8.99E-06 | 1 |
| Premature Operation (Location Source) | 1 | 0.50% | Workmanship | 1 | Faulty Output | 8.99E-06 | 1 |
| Faulty Output | 1 | 0.50% | Category III | 6 | Loose | 8.09E-06 | 3 |
| Grand Total | 201 | Intermittent operation | 3 | Grand Total: | 3.37E-02 | 201 | |
| Opened | 1 | ||||||
| Shorted | 1 | ||||||
| Loose | 1 | ||||||
| Category IV | 149 | ||||||
| Intermittent operation | 44 | ||||||
| Opened | 23 | ||||||
| Shorted | 23 | ||||||
| Failed | 11 | ||||||
| Degraded output or operational capability | 9 | ||||||
| Premature Operation (Timing) | 8 | ||||||
| Failure to Cease Operation (Timing) | 8 | ||||||
| Failure to Operate (Timing) | 5 | ||||||
| Loss of output or failure during operations | 5 | ||||||
| Premature Operation (Zeroize) | 3 | ||||||
| Failure to switch Timing Sources | 2 | ||||||
| Loose | 2 | ||||||
| Faulty Component | 2 | ||||||
| Workmanship | 2 | ||||||
| Faulty Output | 1 | ||||||
| Premature Operation (Location Source) | 1 | ||||||
| Grand Total: | 201 |
Cat I and Cat II
| Parent LRU: | R004-IGRM | ID# | W31P4Q-20-R-0015 | ||||||||||||||||||||
| Component: | Chassis Assembly | 254-379 | ATTACHMENT 0010a.4 | ||||||||||||||||||||
| IGRM GPS Receiver Board | 380-410 | TAB 3 of 4 | |||||||||||||||||||||
| IGRM Processor Board | 411-449 | ||||||||||||||||||||||
| IGRM Power Supply Board | 450-460 | ||||||||||||||||||||||
| Mission Phase-Operational Mode: | All Phases | ||||||||||||||||||||||
| FPMH: | 50.2040 | ||||||||||||||||||||||
| t: | 72 | ||||||||||||||||||||||
| Cr = ∑Cm = | 3.41E-02 | ||||||||||||||||||||||
| Modified Cm = | 4.79E-03 | ||||||||||||||||||||||
| Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-1R or Severity Classification III-2R | |||||||||||||||||||||||
| Failure Effect at | Failure Detection Methods | Compemsating Provisions | |||||||||||||||||||||
| ID# | Subcomponent | Component | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety | ||||||||||||||
| Consideration | Safety | ||||||||||||||||||||||
| Impact | Operator | ||||||||||||||||||||||
| Observation | Visual | ||||||||||||||||||||||
| Indications | C-Bit | ||||||||||||||||||||||
| Capabilities | Severity | ||||||||||||||||||||||
| Classification | Alternate Design | ||||||||||||||||||||||
| Modifications | Modified Severity | ||||||||||||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | |||||||||||||||||
| 254 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – 1PPS UTC Time Pulse Source Selection | Premature Operation (Timing) | Software defect | Function operates early/ unexpectedly | IGRM Mux switches to backup timing source | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0448 | 0.000050204 | 8.09E-05 | 8.09E-06 | |
| 255 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – 1PPS UTC Time Pulse Source Selection | Failure to Operate (Timing) | Software defect | Function operates late or not at all | IGRM Mux not directed to switch to backup timing source | Loss of network communication | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.0498 | 0.000050204 | 1.80E-04 | 8.99E-06 | |
| 257 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – 1PPS UTC Time Pulse Source Selection | Failure to switch Timing Sources | Software defect | IGRM continues to use backup data source | Loss of redundancy. For total loss of function, impending loss of network communication. | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0100 | 0.000050204 | 1.80E-05 | 1.80E-06 | |
| 258 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – 1PPS UTC Time Pulse Source Selection | Loss of output or failure during operations | Software defect | Loss of function | IGRM Mux not directed to switch to backup timing source | Loss of network communication | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.0498 | 0.000050204 | 1.80E-04 | 8.99E-06 | |
| 260 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – Location | Premature Operation (Location Source) | Software defect | Function operates early/ unexpectedly | IGRM switches to backup location source | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0050 | 0.000050204 | 8.99E-06 | 8.99E-07 | |
| 261 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – Location | Failure to Operate (Timing) | Software defect | Function operates late or not at all | IGRM cannot switch to backup location source | Loss of network communication | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.0498 | 0.000050204 | 1.80E-04 | 8.99E-06 | |
| 264 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – Location | Loss of output or failure during operations | Software defect | Loss of function | IGRM cannot switch to backup location source | Loss of network communication | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.0498 | 0.000050204 | 1.80E-04 | 8.99E-06 | |
| 267 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – Output to HNR | Failure to Operate (Timing) | Software defect | Function operates late or not at all | Impending loss of network communication | Impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0498 | 0.000050204 | 8.99E-05 | 8.99E-06 | |
| 268 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – Output to HNR | Intermittent operation | Software defect | Function degraded | Probable impending loss of network communication | Probable impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.2338 | 0.000050204 | 4.23E-04 | 4.23E-05 | |
| 270 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – Output to HNR | Loss of output or failure during operations | Software defect | Loss of function | Impending loss of network communication | Impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0498 | 0.000050204 | 8.99E-05 | 8.99E-06 | |
| 271 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – Output to HNR | Faulty Output | Software defect | Function degraded | Probable impending loss of network communication | Probable impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0050 | 0.000050204 | 8.99E-06 | 8.99E-07 | |
| 273 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – Initialization | Failure to Operate (Timing) | Software defect | Function operates late or not at all | Impending loss of network communication | Impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0498 | 0.000050204 | 8.99E-05 | 8.99E-06 | |
| 274 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – Initialization | Intermittent operation | Software defect | Function degraded | Probable impending loss of network communication | Probable impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.2338 | 0.000050204 | 4.23E-04 | 4.23E-05 | |
| 276 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – Initialization | Loss of output or failure during operations | Software defect | Loss of function | Impending loss of network communication | Impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0498 | 0.000050204 | 8.99E-05 | 8.99E-06 | |
| 277 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – Initialization | Degraded output or operational capability | Software defect | Function degraded | Possible impending loss of network communication | Possible impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0448 | 0.000050204 | 8.09E-05 | 8.09E-06 | |
| 278 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – Common cause failures | Failed | Software defect | Loss of function | Impending loss of network communication | Impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0647 | 0.000050204 | 1.17E-04 | 1.17E-05 | |
| 279 | IGRM Software | R004-01-IGRM Chassis Assembly | NG Radio Kit Custom Software – Dependent failure that affects all similar software modules | Failed | Software defect | Loss of function | Impending loss of network communication | Impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0647 | 0.000050204 | 1.17E-04 | 1.17E-05 | |
| 280 | IGRM Mux | R004-01-IGRM Chassis Assembly | Connector A - Primary input from GPS | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | Loss of redundancy. For total loss of function, impending loss of network communication. | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 281 | IGRM Mux | R004-01-IGRM Chassis Assembly | Connector A - Primary input from GPS | Opened | Hardware failure | No throughput | Loss of redundancy. For total loss of function, impending loss of network communication. | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 283 | IGRM Mux | R004-01-IGRM Chassis Assembly | Connector B – Secondary input from external 1PPS | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | Loss of redundancy. For total loss of function, impending loss of network communication. | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 284 | IGRM Mux | R004-01-IGRM Chassis Assembly | Connector B – Secondary input from external 1PPS | Opened | Hardware failure | No throughput | Loss of redundancy. For total loss of function, impending loss of network communication. | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 286 | IGRM Mux | R004-01-IGRM Chassis Assembly | Connector Y_ - Inverse output to provide SBC with notification when 1PPS is generated | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | Loss of redundancy. For total loss of function, impending loss of network communication. | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 287 | IGRM Mux | R004-01-IGRM Chassis Assembly | Connector Y_ - Inverse output to provide SBC with notification when 1PPS is generated | Opened | Hardware failure | No throughput | Loss of redundancy. For total loss of function, impending loss of network communication. | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 291 | IGRM Mux | R004-01-IGRM Chassis Assembly | Main power input | Shorted | Hardware failure | Power shorted resulting in possible damage to components or tripping of circuit breaker | Impending loss of network communication | Impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 292 | IGRM Mux | R004-01-IGRM Chassis Assembly | Main power input | Opened | Hardware failure | No throughput | Impending loss of network communication | Impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 293 | IGRM Mux | R004-01-IGRM Chassis Assembly | Main power input | Intermittent operation | Hardware failure | Intermittent continuity | Probable impending loss of network communication | Probable impending loss of network communication | N/A | N/A | N/A | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.2338 | 0.000050204 | 4.23E-04 | 4.23E-05 | |
| 294 | IGRM Mux | R004-01-IGRM Chassis Assembly | Main power return | Opened | Hardware failure | No throughput | Impending loss of network communication | Impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 295 | IGRM Mux | R004-01-IGRM Chassis Assembly | Main power return | Intermittent operation | Hardware failure | Intermittent continuity | Probable impending loss of network communication | Probable impending loss of network communication | N/A | N/A | N/A | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.2338 | 0.000050204 | 4.23E-04 | 4.23E-05 | |
| 297 | IGRM Mux | R004-01-IGRM Chassis Assembly | Connector A_/B – Control line to select output | Failure to Operate (Timing) | Hardware failure | Function operates late or not at all | Loss of redundancy. For total loss of function, impending loss of network communication. | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0498 | 0.000050204 | 8.99E-05 | 8.99E-06 | |
| 298 | IGRM Mux | R004-01-IGRM Chassis Assembly | Connector A_/B – Control line to select output | Intermittent operation | Hardware failure | Function degraded | Probable loss of redundancy. For total loss of function, impending loss of network communication. | Probable loss of redundancy. For total loss of function, impending loss of network communication. | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.2338 | 0.000050204 | 4.23E-04 | 4.23E-05 | |
| 299 | IGRM Mux | R004-01-IGRM Chassis Assembly | Connector A_/B – Control line to select output | Failure to switch Timing Sources | Hardware failure | IGRM continues to use backup data source | Loss of redundancy. For total loss of function, impending loss of network communication. | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0100 | 0.000050204 | 1.80E-05 | 1.80E-06 | |
| 300 | IGRM Mux | R004-01-IGRM Chassis Assembly | Connector A_/B – Control line to select output | Loss of output or failure during operations | Hardware failure | Loss of function | Loss of redundancy. For total loss of function, impending loss of network communication. | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0498 | 0.000050204 | 8.99E-05 | 8.99E-06 | |
| 301 | IGRM Mux | R004-01-IGRM Chassis Assembly | Connector A_/B – Control line to select output | Degraded output or operational capability | Hardware failure | Function degraded | Probable loss of redundancy. For total loss of function, impending loss of network communication. | Probable loss of redundancy. For total loss of function, impending loss of network communication. | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0448 | 0.000050204 | 8.09E-05 | 8.09E-06 | |
| 302 | IGRM Mux | R004-01-IGRM Chassis Assembly | Connector Y – 1PPS output | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | Impending loss of network communication | Impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 303 | IGRM Mux | R004-01-IGRM Chassis Assembly | Connector Y – 1PPS output | Opened | Hardware failure | No throughput | Impending loss of network communication | Impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 304 | IGRM Mux | R004-01-IGRM Chassis Assembly | Connector Y – 1PPS output | Intermittent operation | Hardware failure | Intermittent continuity | Probable impending loss of network communication | Probable impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.2338 | 0.000050204 | 4.23E-04 | 4.23E-05 | |
| 305 | IGRM Mux | R004-01-IGRM Chassis Assembly | Common Cause Events - Timing source selection | Faulty Component | Hardware failure | Component inoperative | Impending loss of network communication | Impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0299 | 0.000050204 | 5.40E-05 | 5.40E-06 | |
| 306 | I/O Panel (USB) | R004-01-IGRM Chassis Assembly | USB 0 - Initialization Data Load (J5) | Opened | Hardware failure | No throughput | Assuming mission dictates update of initialization parameters (conservative), impending loss of network communication | Impending loss of network communication | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 307 | I/O Panel (USB) | R004-01-IGRM Chassis Assembly | USB 0 - Initialization Data Load (J5) | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | Assuming mission dictates update of initialization parameters (conservative), impending loss of network communication | Impending loss of network communication | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 308 | I/O Panel (USB) | R004-01-IGRM Chassis Assembly | USB 0 - Initialization Data Load (J5) | Intermittent operation | Hardware failure | Intermittent continuity | Assuming mission dictates update of initialization parameters (conservative), possible impending loss of network communication | Possible impending loss of network communication | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.2338 | 0.000050204 | 4.23E-04 | 4.23E-05 | |
| 313 | I/O Panel (DB) | R004-01-IGRM Chassis Assembly | COM 2 - GPS NMEA Serial (J6, pins 2, 3) | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | BPU cannot perform dynamic key changes without TOD input. Impending IFCN Relay failure. | Impending loss of network communication | N/A | N/A | OB-625-10 | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 314 | I/O Panel (DB) | R004-01-IGRM Chassis Assembly | COM 2 - GPS NMEA Serial (J6, pins 2, 3) | Opened | Hardware failure | No throughput | BPU cannot perform dynamic key changes without TOD input. Impending IFCN Relay failure. | Impending loss of network communication | N/A | N/A | OB-625-10 | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 315 | I/O Panel (DB) | R004-01-IGRM Chassis Assembly | COM 2 - GPS NMEA Serial (J6, pins 2, 3) | Intermittent operation | Hardware failure | Intermittent continuity | BPU cannot perform dynamic key changes without TOD input. Possible impending IFCN Relay failure. | Possible impending loss of network communication | N/A | N/A | OB-625-10 | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.2338 | 0.000050204 | 4.23E-04 | 4.23E-05 | |
| 316 | I/O Panel (DB) | R004-01-IGRM Chassis Assembly | COM 2 - GPS NMEA Serial (J6, pins 2, 3) | Failure to receive/send data ≤ 10 min. of BPU power-up | Hardware failure | BPU cannot properly initialize | IFCN Relay inoperative | Loss of network communication | N/A | N/A | OB-625-10 | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.0100 | 0.000050204 | 3.60E-05 | 1.80E-06 | |
| 319 | I/O Panel (Ethernet) | R004-01-IGRM Chassis Assembly | Ethernet Interface with IGRM (J22) – Receive Control | Opened | Hardware failure | No throughput | IFCN Relay inoperative | Loss of network communication | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.1990 | 0.000050204 | 7.19E-04 | 3.60E-05 | |
| 321 | I/O Panel (Ethernet) | R004-01-IGRM Chassis Assembly | Ethernet Interface with IGRM (J22) – Receive Control | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | IFCN Relay inoperative | Loss of network communication | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.1692 | 0.000050204 | 6.11E-04 | 3.06E-05 | |
| 325 | I/O Panel (Ethernet) | R004-01-IGRM Chassis Assembly | Ethernet Interface with IGRM (J22) | Faulty Component | Hardware failure | Component inoperative | IFCN Relay inoperative | Loss of network communication | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.0299 | 0.000050204 | 1.08E-04 | 5.40E-06 | |
| 326 | I/O Panel (Power) | R004-01-IGRM Chassis Assembly | 28 VDC Power Input to IGRM (J24) - Power (pins 1 through 6) | Opened | Hardware failure | Loss of continuity | IGRM cannot provide data to BPU | Impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 327 | I/O Panel (Power) | R004-01-IGRM Chassis Assembly | 28 VDC Power Input to IGRM (J24) - Power (pins 1 through 6) | Intermittent operation | Hardware failure | Intermittent continuity | IGRM possibly cannot provide data to BPU | Possible impending loss of network communication | N/A | N/A | N/A | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.2338 | 0.000050204 | 4.23E-04 | 4.23E-05 | |
| 328 | I/O Panel (Power) | R004-01-IGRM Chassis Assembly | 28 VDC Power Input to IGRM (J24) - Power (pins 1 through 6) | Shorted | Hardware failure | Power shorted resulting in possible tripping of IGRM circuit breaker | Possible impending loss of network communication | Possible impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 330 | I/O Panel (Power) | R004-01-IGRM Chassis Assembly | 28 VDC Power Input to IGRM (J24) | Faulty Component | Hardware failure | Component inoperative | Impending loss of network communication | Impending loss of network communication | N/A | N/A | N/A | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0299 | 0.000050204 | 5.40E-05 | 5.40E-06 | |
| 331 | I/O Panel (RF) | R004-01-IGRM Chassis Assembly | GPS RF (J100) | Opened | Hardware failure | IGRM cannot process GPS input. | GPS data unavailable. | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 333 | I/O Panel (RF) | R004-01-IGRM Chassis Assembly | GPS RF (J100) | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | GPS data unavailable. | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 334 | I/O Panel (DB, GPS) | R004-01-IGRM Chassis Assembly | COM 3 - SCIM RS232 (J8) - Location from SCIM to IGRM | Opened | Hardware failure | No throughput | Loss of manual input of location | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 336 | I/O Panel (DB, GPS) | R004-01-IGRM Chassis Assembly | COM 3 - SCIM RS232 (J8) - Location from SCIM to IGRM | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | Loss of manual input of location | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 340 | I/O Panel (DB, GPS) | R004-01-IGRM Chassis Assembly | COM 4 – BDDP Serial (J9) | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | IGRM Mux switches to backup data source | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 341 | I/O Panel (DB, GPS) | R004-01-IGRM Chassis Assembly | COM 4 – BDDP Serial (J9) | Opened | Hardware failure | No throughput | IGRM Mux switches to backup data source | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 343 | I/O Panel (DB, GPS) | R004-01-IGRM Chassis Assembly | COM 5 – Multi Function (J30) – GPS Timing | Opened | Hardware failure | No throughput | IGRM Mux switches to backup data source | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | VI-625-05 (Relay SCIM Message-GPS 1PPS Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 345 | I/O Panel (DB, GPS) | R004-01-IGRM Chassis Assembly | COM 5 – Multi Function (J30) – GPS Timing | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | IGRM Mux switches to backup data source | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | VI-625-05 (Relay SCIM Message-GPS 1PPS Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 346 | I/O Panel (DB, GPS) | R004-01-IGRM Chassis Assembly | COM 5 – Multi Function (J30) – GPS Data | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | IGRM Mux switches to backup data source | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 347 | I/O Panel (DB, GPS) | R004-01-IGRM Chassis Assembly | COM 5 – Multi Function (J30) – GPS Data | Opened | Hardware failure | No throughput | IGRM Mux switches to backup data source | Loss of redundancy: For total loss of function, impending loss of network communication. | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 349 | I/O Panel (DB, GPS) | R004-01-IGRM Chassis Assembly | COM 5 – Multi Function (J30) – SCIM Power | Shorted | Hardware failure | Power shorted resulting in possible tripping of IGRM circuit breaker | IFCN Relay possibly inoperative | Possible impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 350 | I/O Panel (DB, GPS) | R004-01-IGRM Chassis Assembly | COM 5 – Multi Function (J30) – SCIM Power | Opened | Hardware failure | No throughput | SCIM inoperable | Loss of redundancy: For total loss of function, impending loss of network communication. Loss of diagnostic capability through SCIM. | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 354 | I/O Panel (DB, GPS) | R004-01-IGRM Chassis Assembly | COM 6 – GPS Fill/Zeroize (J26) – GPS Zeroize | Premature Operation (Zeroize) | Hardware failure | Function operates early/ unexpectedly | Inadvertently erased crypto data and navigational information stored in the GRAM. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | VI-625-08 (Relay SCIM Message-HNR Crypto Key Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0149 | 0.000050204 | 2.70E-05 | 2.70E-06 | |
| 355 | I/O Panel (DB, GPS) | R004-01-IGRM Chassis Assembly | COM 6 – GPS Fill/Zeroize (J26) – GPS Fill | Opened | Hardware failure | No throughput | Unable to load cryptographic keys | In the event of cryptographic key updates, loss of redundancy | N/A | N/A | OB-625-10 | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 357 | I/O Panel (DB, GPS) | R004-01-IGRM Chassis Assembly | COM 6 – GPS Fill/Zeroize (J26) – GPS Fill | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | Unable to load cryptographic keys | In the event of cryptographic key updates, loss of redundancy | N/A | N/A | OB-625-10 | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 360 | Cable Assembly, GPS Internal to IGRM | R004-01-IGRM Chassis Assembly | Internal IGRM Cable - KEYFILL/ 5 VDC Out – GPS Zeroize | Premature Operation (Zeroize) | Hardware failure | Function operates early/ unexpectedly | Inadvertently erased crypto data and navigational information stored in the GRAM. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | VI-625-08 (Relay SCIM Message-HNR Crypto Key Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0149 | 0.000050204 | 2.70E-05 | 2.70E-06 | |
| 362 | Cable Assembly, GPS Internal to IGRM | R004-01-IGRM Chassis Assembly | Internal IGRM Cable - KEYFILL/ 5 VDC Out – GPS Fill | Opened | Hardware failure | No throughput | Unable to load cryptographic keys | In the event of cryptographic key updates, loss of redundancy | N/A | N/A | OB-625-10 | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 364 | Cable Assembly, GPS Internal to IGRM | R004-01-IGRM Chassis Assembly | Internal IGRM Cable - KEYFILL/ 5 VDC Out – GPS Fill | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | Unable to load cryptographic keys | In the event of cryptographic key updates, loss of redundancy | N/A | N/A | OB-625-10 | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 365 | Cable Assembly, GPS Internal to IGRM | R004-01-IGRM Chassis Assembly | Internal IGRM Cable - KEYFILL/ 5 VDC Out – GPS Fill | Workmanship | Manufacturing defect | No throughput | Unable to load cryptographic keys | In the event of cryptographic key updates, loss of redundancy | N/A | N/A | OB-625-10 | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0149 | 0.000050204 | 2.70E-05 | 2.70E-06 | |
| 366 | Cable Assembly, GPS Internal to IGRM | R004-01-IGRM Chassis Assembly | Internal IGRM Cable - GPS Input to GB-GRAM | Opened | Hardware failure | IGRM cannot process GPS input. | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 368 | Cable Assembly, GPS Internal to IGRM | R004-01-IGRM Chassis Assembly | Internal IGRM Cable - GPS Input to GB-GRAM | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 369 | Cable Assembly, GPS Internal to IGRM | R004-01-IGRM Chassis Assembly | Internal IGRM Cable - GPS Input to GB-GRAM | Workmanship | Manufacturing defect | IGRM cannot process GPS input. | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0149 | 0.000050204 | 2.70E-05 | 2.70E-06 | |
| 370 | Cable Assembly, Power Internal to IGRM | R004-01-IGRM Chassis Assembly | Internal IGRM Cable - 28VDC Input from I/O Panel Board to P/S | Opened | Hardware failure | Loss of continuity | IGRM cannot provide data to BPU | Impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 371 | Cable Assembly, Power Internal to IGRM | R004-01-IGRM Chassis Assembly | Internal IGRM Cable - 28VDC Input from I/O Panel Board to P/S | Intermittent operation | Hardware failure | Intermittent continuity | IGRM possibly cannot provide data to BPU | Possible impending loss of network communication | N/A | N/A | N/A | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.2338 | 0.000050204 | 4.23E-04 | 4.23E-05 | |
| 372 | Cable Assembly, Power Internal to IGRM | R004-01-IGRM Chassis Assembly | Internal IGRM Cable - 28VDC Input from I/O Panel Board to P/S | Shorted | Hardware failure | Power shorted resulting in possible tripping of IGRM circuit breaker | Possible impending loss of network communication | Possible impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 373 | Cable Assembly, Power Internal to IGRM | R004-01-IGRM Chassis Assembly | Internal IGRM Cable - Input Voltage Switch Bypass Jumper | Opened | Hardware failure | Loss of continuity | IGRM cannot provide data to BPU | Impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 374 | Cable Assembly, Power Internal to IGRM | R004-01-IGRM Chassis Assembly | Internal IGRM Cable - Input Voltage Switch Bypass Jumper | Intermittent operation | Hardware failure | Intermittent continuity | IGRM possibly cannot provide data to BPU | Possible impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.2338 | 0.000050204 | 4.23E-04 | 4.23E-05 | |
| 375 | Cable Assembly, Power Internal to IGRM | R004-01-IGRM Chassis Assembly | Internal IGRM Cable - Input Voltage Switch Bypass Jumper | Shorted | Hardware failure | Power shorted resulting in possible tripping of IGRM circuit breaker | Possible impending loss of network communication | Possible impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 380 | IGRM Carrier Card | R004-02-IGRM GPS Receiver Board | +5 VDC Pwr Input (P11) | Opened | Hardware failure | IGRM cannot process GPS input. | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 382 | IGRM Carrier Card | R004-02-IGRM GPS Receiver Board | +5 VDC Pwr Input (P11) | Shorted | Hardware failure | Power shorted resulting in possible tripping of IGRM circuit breaker | IFCN Relay possibly inoperative | Possible impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 383 | IGRM Carrier Card | R004-02-IGRM GPS Receiver Board | Connector P3 - GPS BDDP Serial Data (pins 3, 5) | Opened | Hardware failure | Carrier Card cannot send GPS data to SBC. | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 385 | IGRM Carrier Card | R004-02-IGRM GPS Receiver Board | Connector P3 - GPS BDDP Serial Data (pins 3, 5) | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 388 | IGRM Carrier Card | R004-02-IGRM GPS Receiver Board | Connector P3 - GPS Zeroize (pins 7, 9) | Premature Operation (Zeroize) | Hardware failure | Function operates early/ unexpectedly | Inadvertently erased crypto data and navigational information stored in the GRAM. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | VI-625-08 (Relay SCIM Message-HNR Crypto Key Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0149 | 0.000050204 | 2.70E-05 | 2.70E-06 | |
| 389 | IGRM Carrier Card | R004-02-IGRM GPS Receiver Board | Connector P3 – 1PPS Out (pin 10) | Opened | Hardware failure | No throughput | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | VI-625-05 (Relay SCIM Message-GPS 1PPS Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 391 | IGRM Carrier Card | R004-02-IGRM GPS Receiver Board | Connector P3 – 1PPS Out (pin 10) | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 393 | IGRM Carrier Card | R004-02-IGRM GPS Receiver Board | Connector P7 – Keyfill | Opened | Hardware failure | No throughput | Unable to load cryptographic keys | In the event of cryptographic key updates, loss of redundancy | N/A | N/A | OB-625-10 | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 395 | IGRM Carrier Card | R004-02-IGRM GPS Receiver Board | Connector P7 – Keyfill | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | Unable to load cryptographic keys | In the event of cryptographic key updates, loss of redundancy | N/A | N/A | OB-625-10 | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 396 | IGRM Carrier Card | R004-02-IGRM GPS Receiver Board | SMT Connector for GRAM | Opened | Hardware failure | IGRM cannot process GPS input. | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 397 | IGRM Carrier Card | R004-02-IGRM GPS Receiver Board | SMT Connector for GRAM | Intermittent operation | Hardware failure | IGRM possibly cannot process GPS input. | GPS data possibly unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.2338 | 0.000050204 | 4.23E-04 | 4.23E-05 | |
| 398 | IGRM Carrier Card | R004-02-IGRM GPS Receiver Board | SMT Connector for GRAM | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 400 | IGRM Carrier Card | R004-02-IGRM GPS Receiver Board | Carrier Card | Faulty Component | Hardware failure | IGRM cannot process GPS input. | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0299 | 0.000050204 | 5.40E-05 | 5.40E-06 | |
| 401 | IGRM GPS Receiver Application Module (GRAM) | R004-02-IGRM GPS Receiver Board | +3.3 VDC Pwr Input | Opened | Hardware failure | IGRM cannot process GPS input. | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 403 | IGRM GPS Receiver Application Module (GRAM) | R004-02-IGRM GPS Receiver Board | +3.3 VDC Pwr Input | Shorted | Hardware failure | Power shorted resulting in possible tripping of IGRM circuit breaker | IFCN Relay possibly inoperative | Possible impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 404 | IGRM GPS Receiver Application Module (GRAM) | R004-02-IGRM GPS Receiver Board | SMT Connector for Interface with Carrier Card | Opened | Hardware failure | IGRM cannot process GPS input. | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 406 | IGRM GPS Receiver Application Module (GRAM) | R004-02-IGRM GPS Receiver Board | SMT Connector for Interface with Carrier Card | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 407 | IGRM GPS Receiver Application Module (GRAM) | R004-02-IGRM GPS Receiver Board | GPS RF Input | Opened | Hardware failure | IGRM cannot process GPS input. | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 409 | IGRM GPS Receiver Application Module (GRAM) | R004-02-IGRM GPS Receiver Board | GPS RF Input | Shorted | Hardware failure | Data connection shorted resulting in loss of communication | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 410 | IGRM GPS Receiver Application Module (GRAM) | R004-02-IGRM GPS Receiver Board | Carrier Card | Faulty Component | Hardware failure | IGRM cannot process GPS input. | GPS data unavailable. | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0299 | 0.000050204 | 5.40E-05 | 5.40E-06 | |
| 411 | IGRM Single Board Computer | R004-03-IGRM Processor Board | Power Input | Opened | Hardware failure | No throughput | IGRM cannot provide data to BPU | Impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1990 | 0.000050204 | 3.60E-04 | 3.60E-05 | |
| 412 | IGRM Single Board Computer | R004-03-IGRM Processor Board | Power Input | Intermittent operation | Hardware failure | Intermittent continuity | IGRM possibly cannot provide data to BPU | Possible impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.2338 | 0.000050204 | 4.23E-04 | 4.23E-05 | |
| 413 | IGRM Single Board Computer | R004-03-IGRM Processor Board | Power Input | Shorted | Hardware failure | Power shorted resulting in possible tripping of IGRM circuit breaker | IGRM possibly cannot provide data to BPU | Possible impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.1692 | 0.000050204 | 3.06E-04 | 3.06E-05 | |
| 415 | IGRM Single Board Computer | R004-03-IGRM Processor Board | Serial Interface to SCIM | Failure to Operate (Timing) | Hardware failure or software defect | Function operates late or not at all | Operator unable to input location or perform diagnostics at the SCIM | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0498 | 0.000050204 | 8.99E-05 | 8.99E-06 | |
| 418 | IGRM Single Board Computer | R004-03-IGRM Processor Board | Serial Interface to SCIM | Loss of output or failure during operations | Hardware failure or software defect | Loss of function | Operator unable to input location or perform diagnostics at the SCIM | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | OB-625-70 | VI-625-71 (Relay SCIM Display Failure) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0498 | 0.000050204 | 8.99E-05 | 8.99E-06 | |
| 421 | IGRM Single Board Computer | R004-03-IGRM Processor Board | NMEA (Serial) Interface to GRAM | Failure to Operate (Timing) | Hardware failure or software defect | Function operates late or not at all | Loss of Location and TOD data from GPS | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | VI-625-11 (Relay SCIM Message-GPS Location Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0498 | 0.000050204 | 8.99E-05 | 8.99E-06 | |
| 424 | IGRM Single Board Computer | R004-03-IGRM Processor Board | NMEA (Serial) Interface to GRAM | Loss of output or failure during operations | Hardware failure or software defect | Loss of function | Loss of Location and TOD data from GPS | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0498 | 0.000050204 | 8.99E-05 | 8.99E-06 | |
| 427 | IGRM Single Board Computer | R004-03-IGRM Processor Board | Control Interface to Mux | Failure to Operate (Timing) | Hardware failure or software defect | Function operates late or not at all | IGRM Mux cannot switch to backup timing source | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | VI-625-05 (Relay SCIM Message-GPS 1PPS Reported Fault) | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0498 | 0.000050204 | 8.99E-05 | 8.99E-06 | |
| 430 | IGRM Single Board Computer | R004-03-IGRM Processor Board | Control Interface to Mux | Loss of output or failure during operations | Hardware failure or software defect | Loss of function | IGRM Mux cannot switch to backup timing source | Loss of redundancy: for total loss of function, impending loss of network communication | N/A | N/A | N/A | N/A | TBD | Category II | Relays are Redundant | Category III-2R | 0.50 | 0.05 | 0.0498 | 0.000050204 | 8.99E-05 | 8.99E-06 |