This document contains a Failure Modes and Effects Criticality Analysis (FMECA) for the R031 Black Router component of the Integrated Battle Command System (IBCS).
The FMECA identifies 14 potential failure modes for the R031 Black Router, including failures of the Ethernet connector ports, internal power supply, power connectors, and processor. It analyzes the effects of each failure mode at the component, next higher system, and end item levels. It also evaluates the criticality and severity of each failure mode based on criteria like safety impact, detection method, and ability to reconfigure or implement workarounds. The analysis concludes that with redundancies in the overall IBCS system, the severity classifications of the failure modes can be reduced from Category I to Category III-1R. The FMECA is provided as an attachment to Solicitation Number W31P4Q-20-R-0015, which is a request for proposals for the IBCS Low Rate Initial Production/Full Rate Production segment. This segment involves producing IBCS hardware in accordance with supplied specifications and managing any engineering changes, with questions due by December 10, 2020.
View the file
Other files for this federal contract opportunity
Show all 50
RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pivot Table
| W31P4Q-20-R-0015 | ||||
| ATTACHMENT 0010a.13 | ||||
| TAB 1 OF 4 | ||||
| R031-Black Router | ||||
| Row Labels | Count of Failure Mode Description | |||
| Category I | Ethernet connector port fails open | 8 | 0.5714285714 | |
| Ethernet connector port fails open | 8 | Internal Failure | 4 | 0.2857142857 |
| Internal Failure | 4 | Power connector fails open ckt | 1 | 0.0714285714 |
| Power connector fails open ckt | 1 | Power connector fails short ckt | 1 | 0.0714285714 |
| Power connector fails short ckt | 1 | Grand Total | 14 | 1 |
| Grand Total | 14 |
Total Ethernet connector port fails open Internal Failure Power connector fails open ckt Power connector fails short ckt Category I 8 4 1 1
Prelim Analysis
| W31P4Q-20-R-0015 | ||||||
| ATTACHMENT 0010a.13 | ||||||
| TAB 2 OF 4 | ||||||
| PRELIMINARY ANALYSIS: | Parent LRU: | R031-Black Router | ||||
| TCS Tactical Router, Mil-Spec | ||||||
| Mission Phase-Operational Mode: | All Phases | |||||
| Cr = ∑Cm = | 7.70E-04 | |||||
| Failure Modes | Count of | |||||
| Failure Modes | Severity | |||||
| Classifications | Count of |
Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes
| Ethernet connector port fails open | 8 | 57.14% | Category I | 14 | Ethernet connector port fails open | 6.01E-04 | 8 |
| Internal Failure | 4 | 28.57% | Ethernet connector port fails open | 8 | Internal Failure | 1.50E-04 | 4 |
| Power connector fails open ckt | 1 | 7.14% | Internal Failure | 4 | Power connector fails open ckt | 9.39E-06 | 1 |
| Power connector fails short ckt | 1 | 7.14% | Power connector fails open ckt | 1 | Power connector fails short ckt | 9.39E-06 | 1 |
| Grand Total | 14 | Power connector fails short ckt | 1 | Grand Total | 7.70E-04 | 14 | |
| Grand Total | 14 |
Cat I and II
| W31P4Q-20-R-0015 | ||||||||||||||||||||||
| ATTACHMENT 0010a.13 | ||||||||||||||||||||||
| TAB 3 OF 4 | ||||||||||||||||||||||
| Parent LRU: | R031-Black Router | |||||||||||||||||||||
| TCS Tactical Router, Mil-Spec | ||||||||||||||||||||||
| Mission Phase-Operational Mode: | All Phases | |||||||||||||||||||||
| FPMH: | 1.825 | |||||||||||||||||||||
| t: | 72 | hr | ||||||||||||||||||||
| Cr = ∑Cm = | 7.70E-04 | |||||||||||||||||||||
| Modified Cr = | 3.85E-05 | |||||||||||||||||||||
| Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-1R | ||||||||||||||||||||||
| Failure Effect at | Failure Detection Method | Compemsating Provisions | ||||||||||||||||||||
| ID# | Component | |||||||||||||||||||||
| (SRU) | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety | |||||||||||||||
| Consideration | Safety | |||||||||||||||||||||
| Impact | Operator Observation | Visual Indicator | C-Bit | |||||||||||||||||||
| Capabilities | Severity | |||||||||||||||||||||
| Classification | Alternate Design | |||||||||||||||||||||
| Modifications | Modified Severity | |||||||||||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | ||||||||||||||||
| 1261 | Router internal power supply | Receives 28VDC input power and provides power to the internal router circuits | Internal Failure | Hardware Failure | No power to the Relay Black Router | Loss of communications between the IFCN Relay black-side and red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | VI-630-01 (Relay Black Router Power Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2857 | 1.83E-06 | 3.75E-05 | 1.88E-06 | |
| 1262 | Router internal power supply | Receives 28VDC input power and provides power to the internal router circuits | Internal Failure | Hardware Failure | No power to the Relay Black Router, the Relay Network Enclosure "ALT MEDIA" circuit breaker will trip | Loss of communications between the IFCN Relay black-side and red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | VI-630-01 (Relay Black Router Power Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2857 | 1.83E-06 | 3.75E-05 | 1.88E-06 | |
| 1263 | Router internal power supply | Receives 28VDC input power and provides power to the internal router circuits | Internal Failure | Hardware Failure | No power to the Relay Black Router | Loss of communications between the IFCN Relay black-side and red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | VI-630-01 (Relay Black Router Power Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2857 | 1.83E-06 | 3.75E-05 | 1.88E-06 | |
| 1264 | Router Processor | Performs Black Router Processing functions | Internal Failure | Hardware Failure | Loss of all Black Router functions | Loss of communications between the IFCN Relay black-side and red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2857 | 1.83E-06 | 3.75E-05 | 1.88E-06 | |
| 1265 | Power connector | Receives 28VDC input power from the IFCN Relay PDU | Power connector fails open ckt | Hardware Failure | No power to the Relay Black Router | Loss of communications between the IFCN Relay black-side and red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | VI-630-01 (Relay Black Router Power Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.0714 | 1.83E-06 | 9.39E-06 | 4.69E-07 | |
| 1266 | Power connector | Receives 28VDC input power from the IFCN Relay PDU | Power connector fails short ckt | Hardware Failure | No power to the Relay Black Router, the Relay Network Enclosure "ALT MEDIA" circuit breaker will trip | Loss of communications between the IFCN Relay black-side and red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | VI-630-01 (Relay Black Router Power Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.0714 | 1.83E-06 | 9.39E-06 | 4.69E-07 | |
| 1267 | FE 0/0 connector | Ethernet interface to the Relay BPU LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay BPU | Loss of communications between the EOC and the IFCN Relay red-side devices for an "Over-the-Air" connection | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Over-the-Air" connection. Loss of BPU Status for an EOC connected to the Relay using an "Alternate Media" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 | |
| 1268 | FE 0/0 connector | Ethernet interface to the Relay BPU LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay BPU | Loss of communications between the EOC and the IFCN Relay red-side devices for an "Over-the-Air" connection | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Over-the-Air" connection. Loss of BPU Status for an EOC connected to the Relay using an "Alternate Media" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 | |
| 1269 | FE 0/1 connector | Ethernet interface to the Relay KG-250X LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay KG-250X | Loss of communications between the EOC and the IFCN Relay red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 | |
| 1270 | FE 0/1 connector | Ethernet interface to the Relay KG-250X LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay KG-250X | Loss of communications between the EOC and the IFCN Relay red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 | |
| 1271 | FE 0/2 connector | Ethernet interface to the Relay Media Converter Module-1A22 LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay Media Converter Module (Ref-1A22) | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 | |
| 1272 | FE 0/2 connector | Ethernet interface to the Relay Media Converter Module-1A22 LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay Media Converter Module (Ref-1A22) | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 | |
| 1273 | FE 0/3 connector | Ethernet interface to the Relay Media Converter Module-1A23 LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay Media Converter Module (Ref-1A23) | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 | |
| 1274 | FE 0/3 connector | Ethernet interface to the Relay Media Converter Module-1A23 LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay Media Converter Module (Ref-1A23) | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 |
R031 Data
| W31P4Q-20-R-0015 | ||||||||||||||||||||||
| ATTACHMENT 0010a.13 | ||||||||||||||||||||||
| TAB 4 OF 4 | ||||||||||||||||||||||
| Parent LRU: | R031-Black Router | |||||||||||||||||||||
| TCS Tactical Router, Mil-Spec | ||||||||||||||||||||||
| Mission Phase-Operational Mode: | All Phases | |||||||||||||||||||||
| FPMH: | 1.825 | |||||||||||||||||||||
| t: | 72 | hr | ||||||||||||||||||||
| Cr = ∑Cm = | 7.70E-04 | |||||||||||||||||||||
| Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-1R | ||||||||||||||||||||||
| Failure Effect at | Failure Detection Method | Compemsating Provisions | ||||||||||||||||||||
| ID# | Component | |||||||||||||||||||||
| (SRU) | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety | |||||||||||||||
| Consideration | Safety | |||||||||||||||||||||
| Impact | Operator Observation | Visual Indicator | C-Bit | |||||||||||||||||||
| Capabilities | Severity | |||||||||||||||||||||
| Classification | Alternate Design | |||||||||||||||||||||
| Modifications | Modified Severity | |||||||||||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | ||||||||||||||||
| 1261 | Router internal power supply | Receives 28VDC input power and provides power to the internal router circuits | Internal Failure | Hardware Failure | No power to the Relay Black Router | Loss of communications between the IFCN Relay black-side and red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | VI-630-01 (Relay Black Router Power Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2857 | 1.83E-06 | 3.75E-05 | 1.88E-06 | |
| 1262 | Router internal power supply | Receives 28VDC input power and provides power to the internal router circuits | Internal Failure | Hardware Failure | No power to the Relay Black Router, the Relay Network Enclosure "ALT MEDIA" circuit breaker will trip | Loss of communications between the IFCN Relay black-side and red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | VI-630-01 (Relay Black Router Power Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2857 | 1.83E-06 | 3.75E-05 | 1.88E-06 | |
| 1263 | Router internal power supply | Receives 28VDC input power and provides power to the internal router circuits | Internal Failure | Hardware Failure | No power to the Relay Black Router | Loss of communications between the IFCN Relay black-side and red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | VI-630-01 (Relay Black Router Power Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2857 | 1.83E-06 | 3.75E-05 | 1.88E-06 | |
| 1264 | Router Processor | Performs Black Router Processing functions | Internal Failure | Hardware Failure | Loss of all Black Router functions | Loss of communications between the IFCN Relay black-side and red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2857 | 1.83E-06 | 3.75E-05 | 1.88E-06 | |
| 1265 | Power connector | Receives 28VDC input power from the IFCN Relay PDU | Power connector fails open ckt | Hardware Failure | No power to the Relay Black Router | Loss of communications between the IFCN Relay black-side and red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | VI-630-01 (Relay Black Router Power Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.0714 | 1.83E-06 | 9.39E-06 | 4.69E-07 | |
| 1266 | Power connector | Receives 28VDC input power from the IFCN Relay PDU | Power connector fails short ckt | Hardware Failure | No power to the Relay Black Router, the Relay Network Enclosure "ALT MEDIA" circuit breaker will trip | Loss of communications between the IFCN Relay black-side and red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | VI-630-01 (Relay Black Router Power Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.0714 | 1.83E-06 | 9.39E-06 | 4.69E-07 | |
| 1267 | FE 0/0 connector | Ethernet interface to the Relay BPU LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay BPU | Loss of communications between the EOC and the IFCN Relay red-side devices for an "Over-the-Air" connection | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Over-the-Air" connection. Loss of BPU Status for an EOC connected to the Relay using an "Alternate Media" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 | |
| 1268 | FE 0/0 connector | Ethernet interface to the Relay BPU LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay BPU | Loss of communications between the EOC and the IFCN Relay red-side devices for an "Over-the-Air" connection | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Over-the-Air" connection. Loss of BPU Status for an EOC connected to the Relay using an "Alternate Media" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 | |
| 1269 | FE 0/1 connector | Ethernet interface to the Relay KG-250X LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay KG-250X | Loss of communications between the EOC and the IFCN Relay red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 | |
| 1270 | FE 0/1 connector | Ethernet interface to the Relay KG-250X LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay KG-250X | Loss of communications between the EOC and the IFCN Relay red-side devices | Loss of IFCN Relay functions and command/control of any User Platforms connected to the Relay | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 | |
| 1271 | FE 0/2 connector | Ethernet interface to the Relay Media Converter Module-1A22 LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay Media Converter Module (Ref-1A22) | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 | |
| 1272 | FE 0/2 connector | Ethernet interface to the Relay Media Converter Module-1A22 LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay Media Converter Module (Ref-1A22) | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 | |
| 1273 | FE 0/3 connector | Ethernet interface to the Relay Media Converter Module-1A23 LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay Media Converter Module (Ref-1A23) | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 | |
| 1274 | FE 0/3 connector | Ethernet interface to the Relay Media Converter Module-1A23 LRU | Ethernet connector port fails open | Hardware Failure | Loss of the Ethernet interface to the Relay Media Converter Module (Ref-1A23) | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.5714 | 1.83E-06 | 7.51E-05 | 3.75E-06 |