Attachment 0010c.13 – E063 Isolation Router Black-FMECA.xlsx

XLSX spreadsheet 48 KB Posted

Attached to
RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
Solicitation number
W31P4Q-20-R-0015
Issued by
Department of the Army Materiel Command Contracting Command Redstone Arsenal

About this file

This document contains a federal contract opportunity for the Integrated Battle Command System (IBCS) Low Rate Initial Production/Full Rate Production (LRIP/FRP) effort. The Army's Contracting Command at Redstone Arsenal is soliciting proposals to produce IBCS hardware end items in accordance with supplied technical data packages and specifications. Engineering changes may be required for obsolescence, new capabilities, and export considerations. Questions are due by December 10, 2020 at 4pm Central Time. This final RFP is only open to contractors who met entrance criteria through the Beta SAM portal and were approved by the IFMC Project Office. The opportunity involves hardware production as well as maintaining approved software/firmware and ensuring cybersecurity, authority to operate, and engineering change compliance on existing hardware components.

View the file

Other files for this federal contract opportunity

Other files attached to RFP for Integrated Battle Command System (IBCS) LRIP/FRP, newest first.
File Type Posted
W31P4Q-20-R-0015- LRIP FRP - 25NOV2020.pdf PDF
Exhibit B - LRIP FRP TO 0001 DD1423 CDRLs_24NOV2020.pdf PDF
Attachment 0001 - IBCS LRIP FRP Statement of Work - 24NOV2020.docx DOCX document
Attachment 0010a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.2 – R002 BPU-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.6 – R006 TIMING UNIT-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.12 – R030 PFPU SSHD-1—FMECA.xlsx XLSX spreadsheet
Attachment 0010a.14 – R032 Media Converter Module 11-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.1 – E001 28VDC Pwr Supply Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.10 – E034 R112 Shelter – Server Stack – 04-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.6 – E051 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.11 – E061 Isolation Router Red-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.12 – E062 Shelter Router-Red-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.16 – E069 Media Converter 03 - FMECA.xlsx XLSX spreadsheet
Attachment 0010d.1 – E123 TMSS – ECU-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.4 – E151 – Media Converter 04-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.6 – E153 RS112 Server -05 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.3 – E092 thru E101 Wkstn Display-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.5 – E122 – EMI Tent PDU-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.6 – E143 – ICE UPS-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.10 – E148 – Table 4 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0013a -A293-004 ETM 60 Percent Draft_redacted.pdf PDF
Attachment 0013b - IBCS-A301-003 Vol I Student Guide_redacted.pdf PDF
Attachment 0015 - Skill Classification Crosswalk.xlsx XLSX spreadsheet
Attachment 0017 - Pre-Award Survey Accounting System Checklist.pdf PDF
Attachment 0019 - Section L - Instructions - Conditions - and Notices to Offerors - 23NOV2020.docx DOCX document
Attachment 0022a.1.a - ALH-208670 05 IBCS SHELTER INTERC.pdf PDF
Attachment 0022a.1.f - EOC Shelter views.pptx PPTX presentation
Attachment 0022a.1.i - PL-ALH-213030 00 CABLE ASSEMBLY C.pdf PDF
Attachment 0022a.2 - PDRS Support information for integration task.pptx PPTX presentation
Attachment 0026 - Use of Existing Government-Furnished Property.xlsx XLSX spreadsheet
Attachment 0027 - CLIN and SOW Crosswalk - 28OCT2020.docx DOCX document
EXHIBIT A - CONTRACT DATA ITEM REQUIREMENTS LIST (CDRL) - 24NOV2020.pdf PDF
Exhibit C- IBCS DSL - 24NOV2020.docx DOCX document
Attachment 0002 - AIAMD System of Systems (SoS)(MIS-PRF-56500).pdf PDF
Attachment 0004b - Relay Acceptance Test Procedures_FINAL.docx DOCX document
Attachment 0004d - Operator Procedures For IFMC GSIL.docx DOCX document
Attachment 0005 - Software Installation Instructions.docx DOCX document
Attachment 0008 - AIAMD IUID Plan Appendix A - IUID Candidates List Data Items.pdf PDF
Attachment 0009 - R and M Prediction Report.docx DOCX document
Attachment 0010a.3 – R003 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.7 – R007 Relay Network Switch-Parvus Switch-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 0010c.3 – E048 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.8 – E053 Shelter Time Server-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.9 – E059 Shelter Switch – 01-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.8 – E153 RS112 Server -07 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Show all 50

RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet2

W31P4Q-20-R-0015
ATTACHMENT 0010c.13
TAB 1 of 4
Row LabelsSum of CmCount of Failure Mode Description
Erroneous LED indication4.83E-057
Faulty Switch3.45E-056
Faulty Fan2.87E-055
Short6.90E-063
Data bit error4.60E-062
Electrical Overstress1.15E-061
Data word failure1.15E-061
Failure to operate at a prescribed time1.15E-061
Open1.15E-061
Faulty Component1.15E-061
Under/over voltage1.15E-061
Grand Total1.30E-0429

Prelim Analysis

W31P4Q-20-R-0015
ATTACHMENT 0010c.13
TAB 2 of 4
Major End Item:Shelter - Router and Switches
Parent LRU:E063-Isolation Router (Blk)
Component:ISOLATION ROUTER - BLK (A318)
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =1.30E-04
Failure ModesCount of
Failure ModesSeverity ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Erroneous LED indication724.14%Category III26Erroneous LED indication4.83E-057
Faulty Switch620.69%Erroneous LED indication6Faulty Switch3.45E-056
Faulty Fan517.24%Faulty Switch5Faulty Fan2.87E-055
Short310.34%Faulty Fan5Short6.90E-063
Data bit error26.90%Short2Data bit error4.60E-062
Electrical Overstress13.45%Data bit error2Electrical Overstress1.15E-061
Data word failure13.45%Electrical Overstress1Data word failure1.15E-061
Failure to operate at a prescribed time13.45%Data word failure1Failure to operate at a prescribed time1.15E-061
Open13.45%Failure to operate at a prescribed time1Open1.15E-061
Faulty Component13.45%Open1Faulty Component1.15E-061
Under/over voltage13.45%Faulty Component1Under/over voltage1.15E-061
Grand Total29Under/over voltage1Grand Total1.30E-0429
Category IV3
Short1
Erroneous LED indication1
Faulty Switch1
Grand Total29

Cat I and Cat II

W31P4Q-20-R-0015
ATTACHMENT 0010c.13
TAB 3 of 4
No Category I and Category II Classifications

E063 Data

W31P4Q-20-R-0015
ATTACHMENT 0010c.13
TAB 4 of 4
Major End Item:Shelter - Router and Switches
Parent LRU:E063-Isolation Router (Blk)
Component:ISOLATION ROUTER - BLK (A318)
Mission Phase-Operational Mode:All Phases
FPMH:9.258
t:72hr
Cr = ∑Cm =1.30E-04
Modified Cr =1.30E-04
No Category I and Category II Classifications
Failure Effect atFailure Detection MethodCompensating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeveverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
2005Common Cause EventsFaulty ComponentHardware FailureComponent InoperativeLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.053.45E-029.26E-061.15E-061.15E-06
2006Power & Power Distribution.Failure to operate at a prescribed timeHardware FailureLoss of regulated DC powerLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.053.45E-029.26E-061.15E-061.15E-06
2007Power & Power Distribution.Under/over voltageHardware FailureLoss of regulated DC powerLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.053.45E-029.26E-061.15E-061.15E-06
2008Power & Power Distribution.ShortHardware FailureLoss of regulated DC powerLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AShelter CB-22 TRIPSTBDCategory IIIEOCs are RedundantCategory III0.050.051.03E-019.26E-063.45E-063.45E-06
2009Power SwitchFaulty SwitchHardware FailureSwitch opens early/unexpectedlyLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.07E-019.26E-066.90E-066.90E-06
2010Power SwitchFaulty SwitchHardware FailureSwitch opens early/unexpectedlyLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.07E-019.26E-066.90E-066.90E-06
2011Power SwitchFaulty SwitchHardware FailureSwitch opens early/unexpectedlyLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.07E-019.26E-066.90E-066.90E-06
2012Power SwitchFaulty SwitchHardware FailureSwitch opens late or not at all when requiredLoss of ability to remove power when requiredCorrective maintenance required.N/AN/AN/AN/ATBDCategory IVEOCs are RedundantCategory IV0.000.002.07E-019.26E-060.00E+000.00E+00
2013Power SwitchFaulty SwitchHardware FailureSwitch opens early/unexpectedlyLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.07E-019.26E-066.90E-066.90E-06
2014Power SwitchFaulty SwitchHardware FailureSwitch opens early/unexpectedlyLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.07E-019.26E-066.90E-066.90E-06
2015Power SwitchShortHardware FailureSwitch opens late or not at all when requiredLoss of ability to remove power when requiredCorrective maintenance required.N/AN/AN/AN/ATBDCategory IVEOCs are RedundantCategory IV0.000.001.03E-019.26E-060.00E+000.00E+00
2016Switch coolingFaulty FanHardware FailureDegraded air movement by fan assembly.Possible Loss of WIN-T Black Data due to elevated interior temperaturesPossible Degraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.72E-019.26E-065.75E-065.75E-06
2017Switch coolingFaulty FanHardware FailureDegraded air movement by fan assembly.Possible Loss of WIN-T Black Data due to elevated interior temperaturesPossible Degraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.72E-019.26E-065.75E-065.75E-06
2018Switch coolingFaulty FanHardware FailureDegraded air movement by fan assembly.Possible Loss of WIN-T Black Data due to elevated interior temperaturesPossible Degraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.72E-019.26E-065.75E-065.75E-06
2019Switch coolingFaulty FanHardware FailureDegraded air movement by fan assembly.Possible Loss of WIN-T Black Data due to elevated interior temperaturesPossible Degraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.72E-019.26E-065.75E-065.75E-06
2020Switch coolingFaulty FanHardware FailureDegraded air movement by fan assembly.Possible Loss of WIN-T Black Data due to elevated interior temperaturesPossible Degraded Mission due to Loss of WIN-T Blk DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.72E-019.26E-065.75E-065.75E-06
2021LEDsErroneous LED indicationHardware FailureLoss of LED brightnessNo EffectNo EffectN/AN/AN/AN/ATBDCategory IVEOCs are RedundantCategory IV0.000.002.41E-019.26E-060.00E+000.00E+00
2022LEDsErroneous LED indicationHardware FailureLoss of LEDErroneous indicationPossible delay in starting a missionN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.41E-019.26E-068.05E-068.05E-06
2023LEDsErroneous LED indicationHardware FailureLoss of LEDErroneous indicationPossible delay in starting a missionN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.41E-019.26E-068.05E-068.05E-06
2024LEDsErroneous LED indicationHardware FailureLoss of LEDErroneous indicationPossible delay in starting a missionN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.41E-019.26E-068.05E-068.05E-06
2025LEDsErroneous LED indicationHardware FailureLoss of LEDErroneous indicationPossible delay in starting a missionN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.41E-019.26E-068.05E-068.05E-06
2026LEDsErroneous LED indicationHardware FailureLoss of LEDErroneous indicationPossible delay in starting a missionN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.41E-019.26E-068.05E-068.05E-06
2027LEDsErroneous LED indicationHardware FailureLoss of LEDErroneous indicationPossible delay in starting a missionN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.052.41E-019.26E-068.05E-068.05E-06
2028NIPR DATAOpenHardware FailureNo data throughputLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AOB-540-80N/ATBDCategory IIIEOCs are RedundantCategory III0.050.053.45E-029.26E-061.15E-061.15E-06
2029NIPR DATAElectrical OverstressHardware FailurePossible loss of data throughputPossible Loss of WIN-T Black DataPossible Degraded Mission due to Loss of WIN-T Blk DataN/AN/AOB-540-80N/ATBDCategory IIIEOCs are RedundantCategory III0.050.053.45E-029.26E-061.15E-061.15E-06
2030NIPR DATAData bit errorSoftware error (design defect)Spurious data transmittedPossible Loss of WIN-T Black DataPossible Degraded Mission due to Loss of WIN-T Blk DataN/AN/AOB-540-80N/ATBDCategory IIIEOCs are RedundantCategory III0.050.056.90E-029.26E-062.30E-062.30E-06
2031NIPR DATAShortHardware FailureUnreadable data streamingLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AOB-540-80N/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.03E-019.26E-063.45E-063.45E-06
2032NIPR DATAData bit errorHardware FailureUnreadable data streamingLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AOB-540-80N/ATBDCategory IIIEOCs are RedundantCategory III0.050.056.90E-029.26E-062.30E-062.30E-06
2033NIPR DATAData word failureSoftware error (design defect)Unreadable data streamingLoss of WIN-T Black DataDegraded Mission due to Loss of WIN-T Blk DataN/AN/AOB-540-80N/ATBDCategory IIIEOCs are RedundantCategory III0.050.053.45E-029.26E-061.15E-061.15E-06