Attachment 0010b.3 – E005 Blower Assembly-FMECA.xlsx
XLSX spreadsheet 39 KB Posted
- Attached to
- RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
- Solicitation number
- W31P4Q-20-R-0015
About this file
This document contains an attachment to a federal solicitation for an Integrated Battle Command System hardware production effort. The requirement is for the contractor to produce IBCS hardware end items according to supplied technical data packages and specifications, maintain approved software and firmware updates, and execute any engineering changes. This is a Low Rate Initial Production/Full Rate Production segment. The solicitation was issued by the Department of the Army Materiel Command Contracting Command located at Redstone Arsenal. Questions regarding the final RFP were due by December 10, 2020 at 4pm Central Standard Time. The RFP is only open to contractors who met entrance criteria through the Beta SAM portal and were approved by the Integrated Fires Mission Command Project Office.
View the file
Other files for this federal contract opportunity
Show all 50
RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet2
| W31P4Q-20-R-0015 | ||
| ATTACHMENT 0010b.3 | ||
| TAB 1 OF 4 | ||
| Row Labels | Sum of Cm | Count of Failure Mode Description |
| Binding/Sticking | 1.08E-04 | 1 |
| Improper Output | 1.08E-04 | 1 |
| Inoperative | 4.31E-04 | 2 |
| No Current | 1.08E-04 | 1 |
| Will Not Engage | 1.08E-04 | 1 |
| Grand Total | 8.61E-04 | 6 |
Prelim Analysis
| W31P4Q-20-R-0015 | ||||||
| ATTACHMENT 0010b.3 | ||||||
| TAB 2 OF 4 | ||||||
| PRELIMINARY ANALYSIS: | Major End Item: | Shelter - ECU | ||||
| Parent LRU: | E005-Blower Assembly | |||||
| Component: | Blower (Not Critical) | |||||
| Mission Phase-Operational Mode: | All Phases | |||||
| Cr = ∑Cm = | 8.61E-04 | |||||
| Failure Modes | Count of | |||||
| Failure Modes | Severity | |||||
| Classifications | Count of |
Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes
| Inoperative | 2 | 33.33% | Category II | 6 | Inoperative | 4.31E-04 | 2 |
| Binding/Sticking | 1 | 16.67% | Inoperative | 2 | Binding/Sticking | 1.08E-04 | 1 |
| Improper Output | 1 | 16.67% | Binding/Sticking | 1 | Improper Output | 1.08E-04 | 1 |
| No Current | 1 | 16.67% | Improper Output | 1 | No Current | 1.08E-04 | 1 |
| Will Not Engage | 1 | 16.67% | No Current | 1 | Will Not Engage | 1.08E-04 | 1 |
| Grand Total | 6 | Will Not Engage | 1 | Grand Total | 8.61E-04 | 6 | |
| Grand Total | 6 |
Cat I and II
| W31P4Q-20-R-0015 | ||||||||||||||
| ATTACHMENT 0010b.3 | ||||||||||||||
| TAB 3 OF 4 | ||||||||||||||
| Major End Item: | Shelter - ECU | |||||||||||||
| Parent LRU: | E005-Blower Assembly | |||||||||||||
| Componet: | Blower (Not Critical) | |||||||||||||
| Mission Phase-Operational Mode: | All Phases | |||||||||||||
| FPMH: | 35.9454 | |||||||||||||
| t: | 72 | |||||||||||||
| Cr = ∑Cm = | 8.61E-04 | |||||||||||||
| Modified Cr = | 1.73E-04 | (Redundancy) | ||||||||||||
| Due to the remote chance of hazard levels CO the Severity Classifications will remain at Severity Classification II | ||||||||||||||
| Failure Effect at | Failure Detection Method | Compemsating Provisions | ||||||||||||
| ID# | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety Consideration | Safety Impact | Operator Observation | Visual Indicator | C-Bit | |||
| Capabilities | Severity | |||||||||||||
| Classification | Alternate Design | |||||||||||||
| Modifications | Modified Severity | |||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | ||||||||
| 85 | The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied. | Binding/Sticking | Hardware Failure | Probable loss of vent fan | Probable loss of shelter fresh air supply | Possible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied) | Extremely Remote. |
1) Shelter is not typically occupied,
2) LED light on PDP provides indication of Vent Fan Operation,
3) CO Monitor provides annunciation of high CO levels,
| 4) TM provides check of Vent Fan before each field installation | Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration | OB-370-50 | N/A | TBD | Category II | EOCs are Redundant | Category III-2R | 0.50 | 0.05 | 0.1667 | 3.59E-05 | 1.08E-04 | 2.16E-05 |
| 86 | The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied. | Inoperative | Hardware Failure | Loss of vent fan | Loss of shelter fresh air supply | Possible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied) | Extremely Remote. |
1) Shelter is not typically occupied,
2) LED light on PDP provides indication of Vent Fan Operation,
3) CO Monitor provides annunciation of high CO levels,
| 4) TM provides check of Vent Fan before each field installation | Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration | OB-370-50 | N/A | TBD | Category II | EOCs are Redundant | Category III-2R | 0.50 | 0.05 | 0.3333 | 3.59E-05 | 2.15E-04 | 4.31E-05 |
| 87 | The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied. | Improper Output | Hardware Failure | Probable loss of vent fan | Probable loss of shelter fresh air supply | Possible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied) | Extremely Remote. |
1) Shelter is not typically occupied,
2) LED light on PDP provides indication of Vent Fan Operation,
3) CO Monitor provides annunciation of high CO levels,
| 4) TM provides check of Vent Fan before each field installation | Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration | OB-370-50 | N/A | TBD | Category II | EOCs are Redundant | Category III-2R | 0.50 | 0.05 | 0.1667 | 3.59E-05 | 1.08E-04 | 2.16E-05 |
| 88 | The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied. | Inoperative | Hardware Failure | Loss of vent fan | Loss of shelter fresh air supply | Possible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied) | Extremely Remote. |
1) Shelter is not typically occupied,
2) LED light on PDP provides indication of Vent Fan Operation,
3) CO Monitor provides annunciation of high CO levels,
| 4) TM provides check of Vent Fan before each field installation | Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration | OB-370-50 | N/A | TBD | Category II | EOCs are Redundant | Category III-2R | 0.50 | 0.05 | 0.3333 | 3.59E-05 | 2.15E-04 | 4.31E-05 |
| 89 | The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied. | Will Not Engage | Hardware Failure | Loss of vent fan | Loss of shelter fresh air supply | Possible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied) | Extremely Remote. |
1) Shelter is not typically occupied,
2) LED light on PDP provides indication of Vent Fan Operation,
3) CO Monitor provides annunciation of high CO levels,
| 4) TM provides check of Vent Fan before each field installation | Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration | OB-370-50 | N/A | TBD | Category II | EOCs are Redundant | Category III-2R | 0.50 | 0.05 | 0.1667 | 3.59E-05 | 1.08E-04 | 2.16E-05 |
| 90 | The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied. | No Current | Hardware Failure | Loss of vent fan | Loss of shelter fresh air supply | Possible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied) | Extremely Remote. |
1) Shelter is not typically occupied,
2) LED light on PDP provides indication of Vent Fan Operation,
3) CO Monitor provides annunciation of high CO levels,
4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 N/A TBD Category II EOCs are Redundant Category III-2R 0.50 0.05 0.1667 3.59E-05 1.08E-04 2.16E-05
E005 Data
| W31P4Q-20-R-0015 | ||||||||||||||
| ATTACHMENT 0010b.3 | ||||||||||||||
| TAB 4 OF 4 | ||||||||||||||
| Major End Item: | Shelter - ECU | |||||||||||||
| Parent LRU: | E005-Blower Assembly | |||||||||||||
| Componet: | Blower (Not Critical) | |||||||||||||
| Mission Phase-Operational Mode: | All Phases | |||||||||||||
| FPMH: | 35.9454 | |||||||||||||
| t: | 72 | |||||||||||||
| Cr = ∑Cm = | 1.72E-03 | |||||||||||||
| Modified Cr = | 1.73E-04 | (Redundancy) | ||||||||||||
| Due to the remote chance of hazard levels CO the Severity Classifications will remain at Severity Classification II | ||||||||||||||
| Failure Effect at | Failure Detection Methd | Compemsating Provisions | ||||||||||||
| ID# | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety Consideration | Safety Impact | Operator Observation | Visual Indicator | C-Bit | |||
| Capabilities | Severity | |||||||||||||
| Classification | Alternate Design | |||||||||||||
| Modifications | Modified Severity | |||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | ||||||||
| 85 | The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied. | Binding/Sticking | Hardware Failure | Probable loss of vent fan | Probable loss of shelter fresh air supply | Possible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied) | Extremely Remote. |
1) Shelter is not typically occupied,
2) LED light on PDP provides indication of Vent Fan Operation,
3) CO Monitor provides annunciation of high CO levels,
4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and
| Light Indication | N/A | TBD | Category I | EOCs are Redundant | Category III-1R | 1.00 | 0.05 | 0.1667 | 3.59E-05 | 2.15E-04 | 2.16E-05 |
| 86 | The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied. | Inoperative | Hardware Failure | Loss of vent fan | Loss of shelter fresh air supply | Possible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied) | Extremely Remote. |
1) Shelter is not typically occupied,
2) LED light on PDP provides indication of Vent Fan Operation,
3) CO Monitor provides annunciation of high CO levels,
4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and
| Light Indication | N/A | TBD | Category I | EOCs are Redundant | Category III-1R | 1.00 | 0.05 | 0.3333 | 3.59E-05 | 4.31E-04 | 4.31E-05 |
| 87 | The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied. | Improper Output | Hardware Failure | Probable loss of vent fan | Probable loss of shelter fresh air supply | Possible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied) | Extremely Remote. |
1) Shelter is not typically occupied,
2) LED light on PDP provides indication of Vent Fan Operation,
3) CO Monitor provides annunciation of high CO levels,
4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and
| Light Indication | N/A | TBD | Category I | EOCs are Redundant | Category III-1R | 1.00 | 0.05 | 0.1667 | 3.59E-05 | 2.15E-04 | 2.16E-05 |
| 88 | The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied. | Inoperative | Hardware Failure | Loss of vent fan | Loss of shelter fresh air supply | Possible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied) | Extremely Remote. |
1) Shelter is not typically occupied,
2) LED light on PDP provides indication of Vent Fan Operation,
3) CO Monitor provides annunciation of high CO levels,
4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and
| Light Indication | N/A | TBD | Category I | EOCs are Redundant | Category III-1R | 1.00 | 0.05 | 0.3333 | 3.59E-05 | 4.31E-04 | 4.31E-05 |
| 89 | The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied. | Will Not Engage | Hardware Failure | Loss of vent fan | Loss of shelter fresh air supply | Possible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied) | Extremely Remote. |
1) Shelter is not typically occupied,
2) LED light on PDP provides indication of Vent Fan Operation,
3) CO Monitor provides annunciation of high CO levels,
4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and
| Light Indication | N/A | TBD | Category I | EOCs are Redundant | Category III-1R | 1.00 | 0.05 | 0.1667 | 3.59E-05 | 2.15E-04 | 2.16E-05 |
| 90 | The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied. | No Current | Hardware Failure | Loss of vent fan | Loss of shelter fresh air supply | Possible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied) | Extremely Remote. |
1) Shelter is not typically occupied,
2) LED light on PDP provides indication of Vent Fan Operation,
3) CO Monitor provides annunciation of high CO levels,
4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and Light Indication N/A TBD Category I EOCs are Redundant Category III-1R 1.00 0.05 0.1667 3.59E-05 2.15E-04 2.16E-05