Attachment 0010b.3 – E005 Blower Assembly-FMECA.xlsx

XLSX spreadsheet 39 KB Posted

Attached to
RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
Solicitation number
W31P4Q-20-R-0015
Issued by
Department of the Army Materiel Command Contracting Command Redstone Arsenal

About this file

This document contains an attachment to a federal solicitation for an Integrated Battle Command System hardware production effort. The requirement is for the contractor to produce IBCS hardware end items according to supplied technical data packages and specifications, maintain approved software and firmware updates, and execute any engineering changes. This is a Low Rate Initial Production/Full Rate Production segment. The solicitation was issued by the Department of the Army Materiel Command Contracting Command located at Redstone Arsenal. Questions regarding the final RFP were due by December 10, 2020 at 4pm Central Standard Time. The RFP is only open to contractors who met entrance criteria through the Beta SAM portal and were approved by the Integrated Fires Mission Command Project Office.

View the file

Other files for this federal contract opportunity

Other files attached to RFP for Integrated Battle Command System (IBCS) LRIP/FRP, newest first.
File Type Posted
EXHIBIT A - CONTRACT DATA ITEM REQUIREMENTS LIST (CDRL) - 24NOV2020.pdf PDF
Exhibit C- IBCS DSL - 24NOV2020.docx DOCX document
Attachment 0002 - AIAMD System of Systems (SoS)(MIS-PRF-56500).pdf PDF
Attachment 0004b - Relay Acceptance Test Procedures_FINAL.docx DOCX document
Attachment 0004d - Operator Procedures For IFMC GSIL.docx DOCX document
Attachment 0005 - Software Installation Instructions.docx DOCX document
Attachment 0008 - AIAMD IUID Plan Appendix A - IUID Candidates List Data Items.pdf PDF
Attachment 0009 - R and M Prediction Report.docx DOCX document
Attachment 0010a.3 – R003 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.7 – R007 Relay Network Switch-Parvus Switch-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 0010c.3 – E048 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.8 – E053 Shelter Time Server-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.9 – E059 Shelter Switch – 01-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.8 – E153 RS112 Server -07 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0012 - Risk Management Plan.pdf PDF
Attachment 0013c - IBCS-A301-003 Vol II Instructor Guide_redacted.pdf PDF
Attachment 0013f - D-IBCS-0428-001_Delta_Software_SG_redacted.pdf PDF
Attachment 0013g - D-IBCS-0471_Delta2_Suppl_PE_redacted.pdf PDF
Attachment 0014 RevC - Technical Library.docx DOCX document
Attachment 0016 - Example Cage Code and Cognizant DCMA DCAA Information.xlsx XLSX spreadsheet
Attachment 0022a - CASS to PDRS.docx DOCX document
Attachment 0022a.1.e - ALH-215333 00 S-280 CASS INSTALLA.pdf PDF
Attachment 0022a.1.h - PL-ALH-211130 00 CABLE ASSEMBLY C.pdf PDF
Attachment 0022a.4 - CASS Task Purpose.v2.pptx PPTX presentation
Attachment 0025 - DD254.pdf PDF
Attachment 0010b.6 – E030 KVM Console-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.5 – R005 SCIM-FMECA.xlsx XLSX spreadsheet
Attachment 0013i - D-IBCS-0473_Adv_NetMgr.pdf PDF
W31P4Q-20-R-0015- LRIP FRP - 25NOV2020.pdf PDF
Exhibit B - LRIP FRP TO 0001 DD1423 CDRLs_24NOV2020.pdf PDF
Attachment 0001 - IBCS LRIP FRP Statement of Work - 24NOV2020.docx DOCX document
Attachment 0010a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.2 – R002 BPU-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.6 – R006 TIMING UNIT-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.12 – R030 PFPU SSHD-1—FMECA.xlsx XLSX spreadsheet
Attachment 0010a.14 – R032 Media Converter Module 11-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.1 – E001 28VDC Pwr Supply Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.10 – E034 R112 Shelter – Server Stack – 04-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.6 – E051 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.11 – E061 Isolation Router Red-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.12 – E062 Shelter Router-Red-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.16 – E069 Media Converter 03 - FMECA.xlsx XLSX spreadsheet
Attachment 0010d.1 – E123 TMSS – ECU-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.4 – E151 – Media Converter 04-FMECA.xlsx XLSX spreadsheet
Attachment 0010d.6 – E153 RS112 Server -05 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.3 – E092 thru E101 Wkstn Display-FMECA.xlsx XLSX spreadsheet
Show all 50

RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet2

W31P4Q-20-R-0015
ATTACHMENT 0010b.3
TAB 1 OF 4
Row LabelsSum of CmCount of Failure Mode Description
Binding/Sticking1.08E-041
Improper Output1.08E-041
Inoperative4.31E-042
No Current1.08E-041
Will Not Engage1.08E-041
Grand Total8.61E-046

Prelim Analysis

W31P4Q-20-R-0015
ATTACHMENT 0010b.3
TAB 2 OF 4
PRELIMINARY ANALYSIS:Major End Item:Shelter - ECU
Parent LRU:E005-Blower Assembly
Component:Blower (Not Critical)
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =8.61E-04
Failure ModesCount of
Failure ModesSeverity
ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Inoperative233.33%Category II6Inoperative4.31E-042
Binding/Sticking116.67%Inoperative2Binding/Sticking1.08E-041
Improper Output116.67%Binding/Sticking1Improper Output1.08E-041
No Current116.67%Improper Output1No Current1.08E-041
Will Not Engage116.67%No Current1Will Not Engage1.08E-041
Grand Total6Will Not Engage1Grand Total8.61E-046
Grand Total6

Cat I and II

W31P4Q-20-R-0015
ATTACHMENT 0010b.3
TAB 3 OF 4
Major End Item:Shelter - ECU
Parent LRU:E005-Blower Assembly
Componet:Blower (Not Critical)
Mission Phase-Operational Mode:All Phases
FPMH:35.9454
t:72
Cr = ∑Cm =8.61E-04
Modified Cr =1.73E-04(Redundancy)
Due to the remote chance of hazard levels CO the Severity Classifications will remain at Severity Classification II
Failure Effect atFailure Detection MethodCompemsating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety ConsiderationSafety ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
85The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Binding/StickingHardware FailureProbable loss of vent fanProbable loss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.16673.59E-051.08E-042.16E-05
86The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.InoperativeHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.33333.59E-052.15E-044.31E-05
87The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Improper OutputHardware FailureProbable loss of vent fanProbable loss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.16673.59E-051.08E-042.16E-05
88The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.InoperativeHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.33333.59E-052.15E-044.31E-05
89The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Will Not EngageHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.16673.59E-051.08E-042.16E-05
90The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.No CurrentHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 N/A TBD Category II EOCs are Redundant Category III-2R 0.50 0.05 0.1667 3.59E-05 1.08E-04 2.16E-05

E005 Data

W31P4Q-20-R-0015
ATTACHMENT 0010b.3
TAB 4 OF 4
Major End Item:Shelter - ECU
Parent LRU:E005-Blower Assembly
Componet:Blower (Not Critical)
Mission Phase-Operational Mode:All Phases
FPMH:35.9454
t:72
Cr = ∑Cm =1.72E-03
Modified Cr =1.73E-04(Redundancy)
Due to the remote chance of hazard levels CO the Severity Classifications will remain at Severity Classification II
Failure Effect atFailure Detection MethdCompemsating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety ConsiderationSafety ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
85The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Binding/StickingHardware FailureProbable loss of vent fanProbable loss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.16673.59E-052.15E-042.16E-05
86The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.InoperativeHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.33333.59E-054.31E-044.31E-05
87The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Improper OutputHardware FailureProbable loss of vent fanProbable loss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.16673.59E-052.15E-042.16E-05
88The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.InoperativeHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.33333.59E-054.31E-044.31E-05
89The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Will Not EngageHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.16673.59E-052.15E-042.16E-05
90The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.No CurrentHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and Light Indication N/A TBD Category I EOCs are Redundant Category III-1R 1.00 0.05 0.1667 3.59E-05 2.15E-04 2.16E-05