Attachment 0010b.3 – E005 Blower Assembly-FMECA.xlsx

XLSX spreadsheet 39 KB Posted

Attached to
RFP for Integrated Battle Command System (IBCS) LRIP/FRP
Solicitation number
W31P4Q-20-R-0015
Issued by

About this file

This document contains an attachment to a federal solicitation for an Integrated Battle Command System hardware production effort. The requirement is for the contractor to produce IBCS hardware end items according to supplied technical data packages and specifications, maintain approved software and firmware updates, and execute any engineering changes. This is a Low Rate Initial Production/Full Rate Production segment. The solicitation was issued by the Department of the Army Materiel Command Contracting Command located at Redstone Arsenal. Questions regarding the final RFP were due by December 10, 2020 at 4pm Central Standard Time. The RFP is only open to contractors who met entrance criteria through the Beta SAM portal and were approved by the Integrated Fires Mission Command Project Office.

View the file

Other files

File Type Posted
Attachment 0019 - Section L - Instructions Conditions and Notices to Offerors - 7DEC2020.docx DOCX document
Attachment 0010a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 0010a.5 – R005 SCIM-FMECA.xlsx XLSX spreadsheet
Attachment 0013i - D-IBCS-0473_Adv_NetMgr.pdf PDF
Attachment 0010e.4 – E102d thru E111 Vid Extender-FMECA.xlsx XLSX spreadsheet
Attachment 0022a.1.j - PL-ALH-215333 00 S-280 CASS INSTA.pdf PDF
Attachment 0010d.10 – E157 KVM Switch 2 Shelter-FMECA.xlsx XLSX spreadsheet
Attachment 0004a - EOC Acceptance Test Procedures_FINAL.docx DOCX document
Attachment 0010h - SWFMEA Results.xlsx XLSX spreadsheet
Attachment 0010d.1 – E123 TMSS – ECU-FMECA.xlsx XLSX spreadsheet
Attachment 0005 - Software Installation Instructions.docx DOCX document
Attachment 0026 - Use of Existing Government-Furnished Property.xlsx XLSX spreadsheet
Attachment 0010a.6 – R006 TIMING UNIT-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Exhibit C- IBCS DSL - 24NOV2020.docx DOCX document
Attachment 0004d - Operator Procedures For IFMC GSIL.docx DOCX document
Attachment 0010c.11 – E061 Isolation Router Red-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.6 – E051 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.10 – R016 thru R025 Media Converter Module-FMECA.xlsx XLSX spreadsheet
Attachment 0018 - IBCS LRIP FRP IDIQ Pricing Template_29Oct2020 v.3.xlsx XLSX spreadsheet
Attachment 0013c - IBCS-A301-003 Vol II Instructor Guide_redacted.pdf PDF
Attachment 0010e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0016 - Example Cage Code and Cognizant DCMA DCAA Information.xlsx XLSX spreadsheet
Attachment 0022a.1.e - ALH-215333 00 S-280 CASS INSTALLA.pdf PDF
Attachment 0010c.15 – E068 Media Converter 02 – FMECA.xlsx XLSX spreadsheet
Attachment 0010b.4 – E013 ADSI Shelter – Misc Equip-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.10 – E060 Shelter Switch – 02-FMECA.xlsx XLSX spreadsheet
Attachment 0010e.11 – E149 – Table 5 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 0010c.13 – E063 Isolation Router Black-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.15 – R033 Media Converter Module 12-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.5 – E029 KVM Switch 1 Shelter Stack-FMECA.xlsx XLSX spreadsheet
Attachment 0004c - ECT Acceptance Test Procedures_FINAL.DOCX DOCX document
Attachment 0010e.6 – E143 – ICE UPS-FMECA.xlsx XLSX spreadsheet
Attachment 0010b.6 – E030 KVM Console-FMECA.xlsx XLSX spreadsheet
Attachment 0012 - Risk Management Plan.pdf PDF
Attachment 0013a -A293-004 ETM 60 Percent Draft_redacted.pdf PDF
Attachment 0022a.2 - PDRS Support information for integration task.pptx PPTX presentation
Attachment 0010c.16 – E069 Media Converter 03 - FMECA.xlsx XLSX spreadsheet
Attachment 0022a.1.f - EOC Shelter views.pptx PPTX presentation
Attachment 0001 - IBCS LRIP FRP Statement of Work - 24NOV2020.docx DOCX document
Attachment 0010a.2 – R002 BPU-FMECA.xlsx XLSX spreadsheet
Attachment 0010a.4 – R004 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 0022a.1.g - PL-ALH-209032 00 CABLE ASSEMBLY C.pdf PDF
Attachment 0010b.7 – E031 R112 Shelter – Server Stack – 01-FEMCA.xlsx XLSX spreadsheet
Attachment 0004 - Acceptance Test Plan.docx DOCX document
Attachment 0006 - Obsolete Parts List.pdf PDF
Attachment 0010a.11 – R029 PFPU SSHD-1—FMECA.xlsx XLSX spreadsheet
Attachment 0011- Cost Report and Plan.pdf PDF
Attachment 0010d.3 – E150 S-280 PEV-FMECA.xlsx XLSX spreadsheet
Show 40 more

Latest 50 of 128 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet2

W31P4Q-20-R-0015
ATTACHMENT 0010b.3
TAB 1 OF 4
Row LabelsSum of CmCount of Failure Mode Description
Binding/Sticking1.08E-041
Improper Output1.08E-041
Inoperative4.31E-042
No Current1.08E-041
Will Not Engage1.08E-041
Grand Total8.61E-046

Prelim Analysis

W31P4Q-20-R-0015
ATTACHMENT 0010b.3
TAB 2 OF 4
PRELIMINARY ANALYSIS:Major End Item:Shelter - ECU
Parent LRU:E005-Blower Assembly
Component:Blower (Not Critical)
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =8.61E-04
Failure ModesCount of
Failure ModesSeverity
ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Inoperative233.33%Category II6Inoperative4.31E-042
Binding/Sticking116.67%Inoperative2Binding/Sticking1.08E-041
Improper Output116.67%Binding/Sticking1Improper Output1.08E-041
No Current116.67%Improper Output1No Current1.08E-041
Will Not Engage116.67%No Current1Will Not Engage1.08E-041
Grand Total6Will Not Engage1Grand Total8.61E-046
Grand Total6

Cat I and II

W31P4Q-20-R-0015
ATTACHMENT 0010b.3
TAB 3 OF 4
Major End Item:Shelter - ECU
Parent LRU:E005-Blower Assembly
Componet:Blower (Not Critical)
Mission Phase-Operational Mode:All Phases
FPMH:35.9454
t:72
Cr = ∑Cm =8.61E-04
Modified Cr =1.73E-04(Redundancy)
Due to the remote chance of hazard levels CO the Severity Classifications will remain at Severity Classification II
Failure Effect atFailure Detection MethodCompemsating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety ConsiderationSafety ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
85The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Binding/StickingHardware FailureProbable loss of vent fanProbable loss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.16673.59E-051.08E-042.16E-05
86The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.InoperativeHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.33333.59E-052.15E-044.31E-05
87The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Improper OutputHardware FailureProbable loss of vent fanProbable loss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.16673.59E-051.08E-042.16E-05
88The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.InoperativeHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.33333.59E-052.15E-044.31E-05
89The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Will Not EngageHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installationVentilation Hardware Malfunction: Possible Hazardous Carbon Monoxide ConcentrationOB-370-50N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.16673.59E-051.08E-042.16E-05
90The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.No CurrentHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 N/A TBD Category II EOCs are Redundant Category III-2R 0.50 0.05 0.1667 3.59E-05 1.08E-04 2.16E-05

E005 Data

W31P4Q-20-R-0015
ATTACHMENT 0010b.3
TAB 4 OF 4
Major End Item:Shelter - ECU
Parent LRU:E005-Blower Assembly
Componet:Blower (Not Critical)
Mission Phase-Operational Mode:All Phases
FPMH:35.9454
t:72
Cr = ∑Cm =1.72E-03
Modified Cr =1.73E-04(Redundancy)
Due to the remote chance of hazard levels CO the Severity Classifications will remain at Severity Classification II
Failure Effect atFailure Detection MethdCompemsating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety ConsiderationSafety ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
85The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Binding/StickingHardware FailureProbable loss of vent fanProbable loss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.16673.59E-052.15E-042.16E-05
86The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.InoperativeHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.33333.59E-054.31E-044.31E-05
87The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Improper OutputHardware FailureProbable loss of vent fanProbable loss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.16673.59E-052.15E-042.16E-05
88The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.InoperativeHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.33333.59E-054.31E-044.31E-05
89The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.Will Not EngageHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and

Light IndicationN/ATBDCategory IEOCs are RedundantCategory III-1R1.000.050.16673.59E-052.15E-042.16E-05
90The vent fan draws outside filtered air into the shelter through the blower door at a rate of 60 Cubic Feet Per Minute (CFM). Note that the shelter is not typically occupied.No CurrentHardware FailureLoss of vent fanLoss of shelter fresh air supplyPossible personnel illness/death due to high CO concentration (note that EOC Shelter is typically not occupied)Extremely Remote.

1) Shelter is not typically occupied,

2) LED light on PDP provides indication of Vent Fan Operation,

3) CO Monitor provides annunciation of high CO levels,

4) TM provides check of Vent Fan before each field installation Ventilation Hardware Malfunction: Possible Hazardous Carbon Monoxide Concentration OB-370-50 and Light Indication N/A TBD Category I EOCs are Redundant Category III-1R 1.00 0.05 0.1667 3.59E-05 2.15E-04 2.16E-05

Sheet1