Attachment 0010a.16 – R034 Media Converter Power Supply-FMECA.xlsx
XLSX spreadsheet 45 KB Posted
- Attached to
- RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
- Solicitation number
- W31P4Q-20-R-0015
About this file
This document contains an attachment to a federal solicitation for the Integrated Battle Command System (IBCS) Low Rate Initial Production/Full Rate Production segment.
The attachment provides a Failure Modes, Effects and Criticality Analysis (FMECA) for the R034 Media Converter Power Supply component of IBCS. It details three potential failure modes for the power supply: an open or short in the input power circuit, or failure of the output power. For each failure mode, the analysis describes the local, next higher system level, and end item effects. It also provides severity classifications, detection methods, and notes that compensating provisions exist due to redundancy. The federal solicitation seeks production of IBCS hardware in accordance with supplied technical data packages and specifications. It is issued by the Department of the Army Materiel Command Contracting Command located at Redstone Arsenal. Questions regarding the solicitation are due by December 10, 2020 at 4pm Central Time.
View the file
Other files for this federal contract opportunity
Show all 50
RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pivot Table
| W31P4Q-20-R-0015 | ||
| ATTACHMENT 0010a.16 | ||
| TAB 1 of 4 | ||
| R034-Media Converter Power Supply | ||
| Row Labels | Sum of Cm | Count of Failure Mode Description |
| Power Supply Input (Open) | 2.40E-04 | 1 |
| Power Supply Input (Short) | 2.40E-04 | 1 |
| Power Supply Output Fails | 2.40E-04 | 1 |
| Grand Total | 7.20E-04 | 3 |
Prelim Analysis
| W31P4Q-20-R-0015 | ||||||
| ATTACHMENT 0010a.16 | ||||||
| TAB 2 of 4 | ||||||
| PRELIMINARY ANALYSIS: | Parent LRU: | R034-Media Converter Power Supply | ||||
| Media Converter Power Supply | ||||||
| Mission Phase-Operational Mode: | DC-DC Power Supply | |||||
| Cr = ∑Cm = | 7.20E-04 | |||||
| Failure Modes | Count of | |||||
| Failure Modes | Severity | |||||
| Classifications | Count of |
Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes
| Power Supply Input (Open) | 1 | 33.33% | Category I | 3 | Power Supply Input (Open) | 2.40E-04 | 1 |
| Power Supply Input (Short) | 1 | 33.33% | Power Supply Input (Open) | 1 | Power Supply Input (Short) | 2.40E-04 | 1 |
| Power Supply Output Fails | 1 | 33.33% | Power Supply Input (Short) | 1 | Power Supply Output Fails | 2.40E-04 | 1 |
| Grand Total | 3 | Power Supply Output Fails | 1 | Grand Total | 7.20E-04 | 3 | |
| Grand Total | 3 |
Cat I and II
| W31P4Q-20-R-0015 | |||||||||||||||||||||
| ATTACHMENT 0010a.16 | |||||||||||||||||||||
| TAB 3 of 4 | |||||||||||||||||||||
| Parent LRU: | R034-Media Converter Power Supply | ||||||||||||||||||||
| Compoment: | Media Converter Power Supply | ||||||||||||||||||||
| DC-DC Power Supply | |||||||||||||||||||||
| Mission Phase-Operational Mode: | All Phases | ||||||||||||||||||||
| FPMH: | 4.483 | ||||||||||||||||||||
| t: | 72 | hr | |||||||||||||||||||
| Cr = ∑Cm = | 3.23E-04 | ||||||||||||||||||||
| Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-1R | |||||||||||||||||||||
| Failure Effect at | Failure Detection Method | Compemsating Provisions | |||||||||||||||||||
| ID# | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety | ||||||||||||||
| Consideration | Safety | ||||||||||||||||||||
| Impact | Operator Observation | Visual Indicator | C-Bit | ||||||||||||||||||
| Capabilities | Severity | ||||||||||||||||||||
| Classification | Alternate Design | ||||||||||||||||||||
| Modifications | Alternate Design | ||||||||||||||||||||
| Modified β | β | βmod | α | λP | Cm | Mod Cm | |||||||||||||||
| 1295 | Receives 28VDC input power and provides 5VDC output power to the Relay Media Converters (1A22 & 1A23) | Power Supply Input (Open) | Hardware Failure | The Media Converter Power Supply will not provide 5VDC power to the Alternate Media Interface Media Converters | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-20 (Relay Media Converter Power Supply Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.33 | 4.48E-06 | 1.08E-04 | 5.38E-06 | |
| 1296 | Receives 28VDC input power and provides 5VDC output power to the Relay Media Converters (1A22 & 1A23) | Power Supply Input (Short) | Hardware Failure | No power to the Relay Black Router, the Relay Network Enclosure "ALT MEDIA" circuit breaker will trip | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-01 (Relay Black Router Power Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.33 | 4.48E-06 | 1.08E-04 | 5.38E-06 | |
| 1297 | Receives 28VDC input power and provides 5VDC output power to the Relay Media Converters (1A22 & 1A23) | Power Supply Output Fails | Hardware Failure | The Media Converter Power Supply will not provide 5VDC power to the Alternate Media Interface Media Converters | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-20 (Relay Media Converter Power Supply Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.33 | 4.48E-06 | 1.08E-04 | 5.38E-06 |
R034 Data
| W31P4Q-20-R-0015 | |||||||||||||||||||||
| ATTACHMENT 0010a.16 | |||||||||||||||||||||
| TAB 4 of 4 | |||||||||||||||||||||
| Parent LRU: | R034-Media Converter Power Supply | ||||||||||||||||||||
| Compoment: | Media Converter Power Supply | ||||||||||||||||||||
| DC-DC Power Supply | |||||||||||||||||||||
| Mission Phase-Operational Mode: | All Phases | ||||||||||||||||||||
| FPMH: | 10.000 | ||||||||||||||||||||
| t: | 72 | hr | |||||||||||||||||||
| Cr = ∑Cm = | 7.20E-04 | ||||||||||||||||||||
| Modified Cr = | 3.60E-05 | ||||||||||||||||||||
| Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-1R | |||||||||||||||||||||
| Failure Effect at | Failure Detection Method | Compemsating Provisions | |||||||||||||||||||
| ID# | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety | ||||||||||||||
| Consideration | Safety | ||||||||||||||||||||
| Impact | Operator Observation | Visual Indicator | C-Bit | ||||||||||||||||||
| Capabilities | Severity | ||||||||||||||||||||
| Classification | Alternate Design | ||||||||||||||||||||
| Modifications | Modified Severity | ||||||||||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | |||||||||||||||
| 1295 | Receives 28VDC input power and provides 5VDC output power to the Relay Media Converters (1A22 & 1A23) | Power Supply Input (Open) | Hardware Failure | The Media Converter Power Supply will not provide 5VDC power to the Alternate Media Interface Media Converters | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-20 (Relay Media Converter Power Supply Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.33 | 1.00E-05 | 2.40E-04 | 1.20E-05 | |
| 1296 | Receives 28VDC input power and provides 5VDC output power to the Relay Media Converters (1A22 & 1A23) | Power Supply Input (Short) | Hardware Failure | No power to the Relay Black Router, the Relay Network Enclosure "ALT MEDIA" circuit breaker will trip | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-01 (Relay Black Router Power Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.33 | 1.00E-05 | 2.40E-04 | 1.20E-05 | |
| 1297 | Receives 28VDC input power and provides 5VDC output power to the Relay Media Converters (1A22 & 1A23) | Power Supply Output Fails | Hardware Failure | The Media Converter Power Supply will not provide 5VDC power to the Alternate Media Interface Media Converters | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-20 (Relay Media Converter Power Supply Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.33 | 1.00E-05 | 2.40E-04 | 1.20E-05 |