Attachment 0010a.14 – R032 Media Converter Module 11-FMECA.xlsx
XLSX spreadsheet 45 KB Posted
- Attached to
- RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
- Solicitation number
- W31P4Q-20-R-0015
About this file
This document contains a Failure Modes and Effects Analysis (FMEA) for an Integrated Battle Command System (IBCS) hardware component. The FMEA evaluates potential failure modes for a Media Converter Module used in IBCS Relay systems. It identifies 10 possible failure modes including failures of the power supply, internal electronics, data connectors, and signal interfaces. For each failure mode, the FMEA details the potential local and system-level effects, detection methods, safety impacts, and proposes a modified severity classification of Category III-1R given redundancy of IBCS Relay systems. The FMEA was conducted to support the Hardware Low Rate Initial Production/Full Rate Production requirement under solicitation number W31P4Q-20-R-0015. This requirement is for the Department of the Army to produce IBCS hardware items in accordance with technical specifications, address any engineering changes, and maintain approved software and configuration management over the contract period of performance. Questions on this RFP were due by December 10, 2020.
View the file
Other files for this federal contract opportunity
Show all 50
RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pivot Table 32
| W31P4Q-20-R-0015 | |||||
| ATTACHMENT 0010a.14 | |||||
| TAB 1 of 4 | |||||
| R032-Media Converter Module #11 | |||||
| Row Labels | Sum of Cm | Count of Failure Mode Description | |||
| Internal Failure | 2.15E-05 | 2 | Fiber Connector Port Fails | 2 | 0.2 |
| Fiber Connector Port Fails | 2.15E-05 | 2 | Power Supply input (Short) | 1 | 0.1 |
| Ethernet Connector Port (Open) | 2.15E-05 | 2 | Power Supply Input (Open) | 1 | 0.1 |
| Power Supply Input (Open) | 5.37E-06 | 1 | Internal Failure | 2 | 0.2 |
| Power Supply input (Short) | 5.37E-06 | 1 | Ethernet Connector Port (Open) | 2 | 0.2 |
| Power connector fails (Open) | 5.37E-06 | 1 | Power connector fails (Open) | 1 | 0.1 |
| Power connector fails (Short) | 5.37E-06 | 1 | Power connector fails (Short) | 1 | 0.1 |
| Grand Total | 8.60E-05 | 10 | 10 | 1 |
Prelim Analsis 32
| W31P4Q-20-R-0015 | ||||||
| ATTACHMENT 0010a.14 | ||||||
| TAB 2 of 4 | ||||||
| PRELIMINARY ANALYSIS: | Parent LRU: | R032-Media Converter Module #11 | ||||
| 10/100TX to 100 FX Media Converter Module | ||||||
| Mission Phase-Operational Mode: | All Phases | |||||
| Cr = ∑Cm = | 8.60E-05 | |||||
| Failure Modes | Count of | |||||
| Failure Modes | Severity | |||||
| Classifications | Count of |
Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes
| Fiber Connector Port Fails | 2 | 20.00% | Category I | 10 | Internal Failure | 2.15E-05 | 2 |
| Internal Failure | 2 | 20.00% | Fiber Connector Port Fails | 2 | Fiber Connector Port Fails | 2.15E-05 | 2 |
| Ethernet Connector Port (Open) | 2 | 20.00% | Internal Failure | 2 | Ethernet Connector Port (Open) | 2.15E-05 | 2 |
| Power Supply input (Short) | 1 | 10.00% | Power connector fails (Open) | 1 | Power Supply Input (Open) | 5.37E-06 | 1 |
| Power Supply Input (Open) | 1 | 10.00% | Power connector fails (Short) | 1 | Power Supply input (Short) | 5.37E-06 | 1 |
| Power connector fails (Open) | 1 | 10.00% | Power Supply Input (Open) | 1 | Power connector fails (Open) | 5.37E-06 | 1 |
| Power connector fails (Short) | 1 | 10.00% | Power Supply input (Short) | 1 | Power connector fails (Short) | 5.37E-06 | 1 |
| Grand Total: | 10 | Ethernet Connector Port (Open) | 2 | Grand Total | 8.60E-05 | 10 | |
| Grand Total | 10 |
32 Cat I and II
| W31P4Q-20-R-0015 | ||||||||||||||||||||||
| ATTACHMENT 0010a.14 | ||||||||||||||||||||||
| TAB 3 of 4 | ||||||||||||||||||||||
| Parent LRU: | R032-Media Converter Module #11 | |||||||||||||||||||||
| Mission Phase-Operational Mode: | All Phases | |||||||||||||||||||||
| FPMH: | 1.629 | |||||||||||||||||||||
| t: | 72 | hr | ||||||||||||||||||||
| Cr = ∑Cm = | 1.88E-04 | |||||||||||||||||||||
| Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-1R | ||||||||||||||||||||||
| Failure Effect at | Failure Detection Method | Compemsating Provisions | ||||||||||||||||||||
| ID# | Component | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety | ||||||||||||||
| Consideration | Safety | |||||||||||||||||||||
| Impact | Operator Observation | Visual Indicator | C-Bit | |||||||||||||||||||
| Capabilities | Severity | |||||||||||||||||||||
| Classification | Alternate Design | |||||||||||||||||||||
| Modifications | Modified Severity | |||||||||||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | ||||||||||||||||
| 1275 | Media Converter internal power supply | Receives 5VDC input power and provides power to the internal Media Converter circuits | Power Supply Input (Open) | Hardware Failure | No power to the Relay Media Converter module (1A22) | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-30 (Relay Media Converter Module #11 Power Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.1000 | 1.63E-06 | 1.17E-05 | 5.87E-07 | |
| 1276 | Media Converter internal power supply | Receives 5VDC input power and provides power to the internal Media Converter circuits | Power Supply input (Short) | Hardware Failure | No power to the Relay Media Converter Modules (1A22 & 1A23) | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-20 (Relay Media Converter Power Supply Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.1000 | 1.63E-06 | 1.17E-05 | 5.87E-07 | |
| 1277 | Media Converter internal power supply | Receives 5VDC input power and provides power to the internal Media Converter circuits | Internal Failure | Hardware Failure | No power to the Relay Media Converter | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-30 (Relay Media Converter Module #11 Power Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.63E-06 | 2.35E-05 | 1.17E-06 | |
| 1278 | Media Converter Processor | Performs Media Converter Processing functions | Internal Failure | Hardware Failure | Loss of all Media Converter (1A22) functions | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.63E-06 | 2.35E-05 | 1.17E-06 | |
| 1279 | Power connector | Receives 5VDC input power from the IFCN Relay Media Converter Power Supply | Power connector fails (Open) | Hardware Failure | No power to the Relay Media Converter module (1A22) | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-30 (Relay Media Converter Module #11 Power Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.1000 | 1.63E-06 | 1.17E-05 | 5.87E-07 | |
| 1280 | Power connector | Receives 5VDC input power from the IFCN Relay Media Converter Power Supply | Power connector fails (Short) | Hardware Failure | No power to the Relay Media Converter Modules (1A22 & 1A23) | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-20 (Relay Media Converter Power Supply Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.1000 | 1.63E-06 | 1.17E-05 | 5.87E-07 | |
| 1281 | FE connector | Ethernet interface to the Relay Black Router LRU | Ethernet Connector Port (Open) | Hardware Failure | Loss of the Ethernet interface to the Relay Black Router | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.63E-06 | 2.35E-05 | 1.17E-06 | |
| 1282 | FE connector | Ethernet interface to the Relay Black Router LRU | Ethernet Connector Port (Open) | Hardware Failure | Loss of the Ethernet interface to the Relay Black Router | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.63E-06 | 2.35E-05 | 1.17E-06 | |
| 1283 | Rx connector | Fiber interface (Receive data) to the EOC Shelter Media Converter | Fiber Connector Port Fails | Hardware Failure | Loss of the Fiber "Receive data" interface to the EOC Shelter Alternate Media | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.63E-06 | 2.35E-05 | 1.17E-06 | |
| 1284 | Tx connector | Fiber interface (Transmit data) to the EOC Shelter Media Converter | Fiber Connector Port Fails | Hardware Failure | Loss of the Fiber "Transmit data" interface to the EOC Shelter Alternate Media | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 1.63E-06 | 2.35E-05 | 1.17E-06 |
Data 32
| W31P4Q-20-R-0015 | ||||||||||||||||||||||
| ATTACHMENT 0010a.14 | ||||||||||||||||||||||
| TAB 4 of 4 | ||||||||||||||||||||||
| Parent LRU: | R032-Media Converter Module #11 | |||||||||||||||||||||
| Mission Phase-Operational Mode: | All Phases | |||||||||||||||||||||
| FPMH: | 0.746 | |||||||||||||||||||||
| t: | 72 | hr | ||||||||||||||||||||
| Cr = ∑Cm = | 8.60E-05 | |||||||||||||||||||||
| Modified Cr = | 4.30E-06 | |||||||||||||||||||||
| Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-1R | ||||||||||||||||||||||
| Failure Effect at | Failure Detection Method | Compemsating Provisions | ||||||||||||||||||||
| ID# | Component | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety | ||||||||||||||
| Consideration | Safety | |||||||||||||||||||||
| Impact | Operator Observation | Visual Indicator | C-Bit | |||||||||||||||||||
| Capabilities | Severity | |||||||||||||||||||||
| Classification | Alternate Design | |||||||||||||||||||||
| Modifications | Modified Severity | |||||||||||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | ||||||||||||||||
| 1275 | Media Converter internal power supply | Receives 5VDC input power and provides power to the internal Media Converter circuits | Power Supply Input (Open) | Hardware Failure | No power to the Relay Media Converter module (1A22) | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-30 (Relay Media Converter Module #11 Power Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.1000 | 7.46E-07 | 5.37E-06 | 2.69E-07 | |
| 1276 | Media Converter internal power supply | Receives 5VDC input power and provides power to the internal Media Converter circuits | Power Supply input (Short) | Hardware Failure | No power to the Relay Media Converter Modules (1A22 & 1A23) | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-20 (Relay Media Converter Power Supply Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.1000 | 7.46E-07 | 5.37E-06 | 2.69E-07 | |
| 1277 | Media Converter internal power supply | Receives 5VDC input power and provides power to the internal Media Converter circuits | Internal Failure | Hardware Failure | No power to the Relay Media Converter | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-30 (Relay Media Converter Module #11 Power Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 7.46E-07 | 1.07E-05 | 5.37E-07 | |
| 1278 | Media Converter Processor | Performs Media Converter Processing functions | Internal Failure | Hardware Failure | Loss of all Media Converter (1A22) functions | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 7.46E-07 | 1.07E-05 | 5.37E-07 | |
| 1279 | Power connector | Receives 5VDC input power from the IFCN Relay Media Converter Power Supply | Power connector fails (Open) | Hardware Failure | No power to the Relay Media Converter module (1A22) | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-30 (Relay Media Converter Module #11 Power Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.1000 | 7.46E-07 | 5.37E-06 | 2.69E-07 | |
| 1280 | Power connector | Receives 5VDC input power from the IFCN Relay Media Converter Power Supply | Power connector fails (Short) | Hardware Failure | No power to the Relay Media Converter Modules (1A22 & 1A23) | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | VI-630-20 (Relay Media Converter Power Supply Indicator Fault) | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.1000 | 7.46E-07 | 5.37E-06 | 2.69E-07 | |
| 1281 | FE connector | Ethernet interface to the Relay Black Router LRU | Ethernet Connector Port (Open) | Hardware Failure | Loss of the Ethernet interface to the Relay Black Router | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 7.46E-07 | 1.07E-05 | 5.37E-07 | |
| 1282 | FE connector | Ethernet interface to the Relay Black Router LRU | Ethernet Connector Port (Open) | Hardware Failure | Loss of the Ethernet interface to the Relay Black Router | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 7.46E-07 | 1.07E-05 | 5.37E-07 | |
| 1283 | Rx connector | Fiber interface (Receive data) to the EOC Shelter Media Converter | Fiber Connector Port Fails | Hardware Failure | Loss of the Fiber "Receive data" interface to the EOC Shelter Alternate Media | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 7.46E-07 | 1.07E-05 | 5.37E-07 | |
| 1284 | Tx connector | Fiber interface (Transmit data) to the EOC Shelter Media Converter | Fiber Connector Port Fails | Hardware Failure | Loss of the Fiber "Transmit data" interface to the EOC Shelter Alternate Media | Loss of the IFCN Relay Alternate Media interface function | Loss of IFCN Relay functions and command/control of any User Platforms for an EOC connected to the Relay using an "Alternate Media" connection. No impact if the EOC is connected to the Relay using an "Over-the-Air" connection. | N/A | N/A | N/A | N/A | TBD | Category I | Relays are Redundant | Category III-1R | 1.00 | 0.05 | 0.2000 | 7.46E-07 | 1.07E-05 | 5.37E-07 |
File details come from the government source that posted it. Updated .