Attach B Drawings and Sheet Specs.pdf
PDF 6 MB Posted
- Attached to
- Communication Conduit Installation
- Solicitation number
- S-14100-00014230
- Issued by
- Coos County, Cheshire CDP, Oregon
About this file
The document is a set of engineering design drawings for the South Slough Entrance and Roadway Improvements project, prepared by Civil West Engineering Services, Inc. for the Oregon Department of State Lands. The project is located at 61907 Seven Devils Road in Charleston, Oregon, and focuses on fiber optic installation and roadway improvements for the South Slough National Estuarine Research Reserve. The drawings are dated May 2025 and include detailed plans for installing 4" and 2" HDPE conduits for fiber lines, pull boxes, utility vaults, and building penetrations across multiple project phases.
The project involves creating new internet service for existing buildings, installing conduits at specific offsets from existing pavement, and setting up pull boxes at elevations ranging from 330.5' to 375'. The design includes precise details for wall penetrations, utility vault configurations, and conduit routing, with a focus on minimizing environmental impact. The project appears to be funded by the Oregon Department of State Lands and involves careful planning for infrastructure improvements at the South Slough National Estuarine Research Reserve, with specific attention to technical details of fiber optic and communication infrastructure installation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SSNERR Comms Conduit Dwgs_Spec_Rev1_20250709.pdf | ||
| RFQ Communication Conduit Installation.pdf | ||
| Comms Conduit Pre Bid QandA.pdf | ||
| Attach A South Slough IDP_VC Entrance Project.pdf | ||
| Comms Conduit Install Bid Form_Rev 1.xlsx | XLSX spreadsheet | |
| RFP Walkin Cooler.doc | DOC document | |
| Attach C Bid Form~1.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R
EV
D
AT
E
D
ES
C R
IP
TI
O N
BY
D es ig ne d By
D ra w n By
C he ck ed B y:
D at e Sh ee t N o.
Pr oj ec t N o:
C oo s Ba y, O re go n
E St re et w w w .c iv ilw es t.c om
1-
6-
D
AT
E:5 /1
9/
F
IL
E:S :\2
M is c Pr iv at e En gi ne er in g W or k\
-3
S ta te o f O re go n
- S ou th S lo ug h En tra nc e an d R oa dw ay Im pr ov em en ts \0
D es ig n Se rv ic es \C
AD
\2
4-
FI
BE
R E
XH
IB
IT
.d w g
R
EG I N
E
N
11, S
PE
89522PE
OREGON
E
0SEAN D A L LOYD
RENEWS: 12/31/26
REG
I STERED PROFESS I ONAL
E N
G1
SO
U
TH
S
LO
U
G H
E N
TR
AN
C E
AN
D
R O
AD
W
AY
IM
PR
O
VE
M
EN
TS
O R
EG
O
N D
EP
T.
O F
ST
AT
E
LA
N D
S
C
SK
C
SK
-3
MAY 2025
SE
VE
N
D
EV
IL
S
R D
, C H
AR
LE
ST
O
N , O
R
LOCATION MAP
PORTLAND
SALEM
EUGENE
COOS BAY
LONGVIEW
THE DALLES
PENDLETON
BEND
BURNS
KLAMATH FALLSMEDFORDBROOKINGS
CRESCENT CITY
ROSEBURG
SEAL ROCK
SPRINGFIELD
CORVALLIS
ONTARIO
GRANTS PASS
C
AL
IF
N
EV
OREGON
NEVADA
WASHINGTON
P A C
IF
IC
O C E A N
LA GRANDE
BURNS
JUNCTION
CALIFORNIA
ASHLAND
TILLAMOOK
SEASIDE
LINCOLN CITY
NEWPORT
MYRTLE POINT
FLORENCE
BANDON
PORT ORFORD
GOLD BEACH
EAGLE POINT
ADAIR VILLAGE
N
PROJECT
LOCATION
N
CONTACT INFORMATION
OREGON DEPARTMENT OF STATE LANDS
CONTACT:
TITLE:
EMAIL:
PHONE:
OWNER
JULIANA RUBLE
PROJECT MANAGER
JULIANA.A.RUBLE@DSL.OREGON.GOV
971-493-2898
CIVIL WEST ENGINEERING SERVICES, INC.
CONTACT:
TITLE:
EMAIL:
PHONE:
ENGINEER
WILL DAWSON
PRINCIPAL
WDAWSON@CIVILWEST.NET
541-266-8601
PROJECT LOCATION
SITE VICINITY MAP
NOT TO SCALE
G1 COVER
G2 LEGEND AND ABBREVIATIONS
G3 NOTES
C1 FIBER OPTIC INSTALLATION
C2 FIBER OPTIC INSTALLATION
D1 DETAILS
SHEET INDEX
PROJECT NUMBER: 2204-372
MAY 2025
SOUTH SLOUGH ENTRANCE AND
ROADWAY IMPROVEMENTS
OREGON DEPARTMENT OF
STATE LANDS
SOUTH SLOUGH NATIONAL ESTUARINE
RESEARCH RESERVE
AutoCAD SHX Text
COVER
AutoCAD SHX Text 99W
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
D
AT
E
D
ES
C R
IP
TI
O N
BY
D es ig ne d By
D ra w n By
C he ck ed B y:
D at e Sh ee t N o.
Pr oj ec t N o:
C oo s Ba y, O re go n
E St re et w w w .c iv ilw es t.c om
1-
6-
D
AT
E:5 /1
9/
F
IL
E:S :\2
M is c Pr iv at e En gi ne er in g W or k\
-3
S ta te o f O re go n
- S ou th S lo ug h En tra nc e an d R oa dw ay Im pr ov em en ts \0
D es ig n Se rv ic es \C
AD
\2
4-
FI
BE
R E
XH
IB
IT
.d w g
R
EG I N
E
N
11, S
PE
89522PE
OREGON
E
0SEAN D A L LOYD
RENEWS: 12/31/26
REG
I STERED PROFESS I ONAL
E N
G2
SO
U
TH
S
LO
U
G H
E N
TR
AN
C E
AN
D
R O
AD
W
AY
IM
PR
O
VE
M
EN
TS
O R
EG
O
N D
EP
T.
O F
ST
AT
E
LA
N D
S
C
SK
C
SK
-3
MAY 2025
SE
VE
N
D
EV
IL
S
R D
, C H
AR
LE
ST
O
N , O
R
A ________________________________
AC ASPHALTIC CONCRETE
A/C AIR CONDITIONING
ADWF AVERAGE DRY WEATHER FLOW
AG AGITATOR
AMD AIR MONITORING DEVICE
ANC ANCHOR
AUX AUXILARY
B_________________________________
BAC BACTERIOLOGICAL
BC BEGINNING OF CURVE
BCR BEGINNING OF CURVE RETURN
BF BLIND FLANGE
BFP BACKFLOW PREVENTER
BHP BRAKE HORSEPOWER
BLDG BUILDING
BO BLOW OFF
BOD BIOCHEMICAL OXYGEN DEMAND
BOW BACK OF WALK
C_________________________________
CAB DIRECT BURIAL CABLE
CAF COMBUSTION AIR FAN
CC COOLING COIL
C:C CENTER TO CENTER
CCP CONCRETE CYLINDER PIPE
CCSPCONCRETE LINED AND COATED STEEL PIPE
CDS CONDENSATE
CF CUBIC FEET
CFH CUBIC FEET PER HOUR
CJ CONSTRUCTION JOINT
CFM CUBIC FEET PER MINUTE
CFR CODE OF FEDERAL REGULATIONS
CIRC CIRCUMFERENCE
CL CENTERLINE
CLR CLEARANCE
CL2 CHLORINE
CCR CLEAR CONCRETE COVER
CMC CEMENT MORTAR COATED
CML CEMENT MORTAR LINED
CMP CORRUGATED MEDAL PIPE
CMU CONCRETE MASONARY UNIT
CNTL CONTROL
CO2 CARBON DIOXIDE
COD CHEMICAL OXYGEN DEMAND
CLF COOLING AIR FAN
CONC CONCRETE
CO CLEAN OUT
CONC CONCRETE
CONTCONTINUED
CPVC CHLORINATED POLYVINYL CHLORIDE
CREJ CORRUGATED RUBBER EXPANSION JOINT
CS CURED SLUDGE
CTR CONTRACTOR, CENTER
CU CONTROL UNIT
D_________________________________
DE DENSITY METER
DF DRINKING FOUNTAIN
DIA DIAMETER
DM DAMPER MOTOR
DO DISSOLVED OXYGEN
DP DEEP
DR DRAIN ROCK
DS DECANT SLUDGE
D/S DOWN SPOUT
DT DRAIN TRAP
DWF DRY WEATHER FLOW
DWL DOWEL
E_________________________________
E EAST
EC END OF CURVE
EE EACH END
EF EACH FACE
EFF EFFLUENT
EJ EXPANSION JOINT
EL ELEVATION
ELB ELBOW
EMBD EMBEDDED
EP ENCLOSURE PANEL
EVP EVAPORATOR
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EWEFEACH WAH EACH FACE
EX EXISTING
EXH EXHAUST
F_________________________________
F FAHRENHEIT
FB FLAT BAR
FCO FLOOR CLEAN OUT
FCR FINE CRUSHED ROCK
FF FINISHED FLOOR, FAR FACE
F:F FACE TO FACE
FH FIRE HYDRANT
FIN FINISHED
FL FLOWLINE
FLG FLANGE
FLM FLOW METER
FLP FLUID POWER UNIT
FLR FLOOR
FM FORCE MAIN
FMH FLEXIBLE METAL HOSE
FPC FLEXIBLE PIPE COUPLING
FRP FIBERGLASS REINFORCED PLASTIC
FS FAR SIDE
FLS FLOW SWTICH
FT FOOT
FTG FOOTING
G_________________________________
GDR GRINDER
GL GUTTER LINE
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GRT GROUT
GSP GALVANIZED STEEL PIPE
GT GATE
H_________________________________
H/A HAND AUTO
HB HOUSE BIB
HOA HAND-OFF-AUTO
HOR HORIZONTAL
HP HORSEPOWER
HR HANDRAIL
HV HOSE VALVE
HVACHEATING, VENTILATION, AND AIR
CONDITIONING
H2E HOOK TO ENDS
I_________________________________
ICR INCINERATOR
IE INVERT ELEVATION
IF INSIDE FACE
INF INFLUENT
INTER INTERMEDIATE
INV INVERT
IT INSTRUMENT TAP
K_________________________________
K KIP (1000 POUNDS)
L_________________________________
LAT LATERAL
LPF LIQUID POLYMER FEEDER
LSS LIME STABALIZED SLUDGE
LVA LOW VELOCITY ANCHOR
M_________________________________
MACS MANUAL AUTO-CONTROL STATION
MAX MAXIMUM
MCC MOTOR CONTROL CENTER
MCS MANUAL CONTROL STATION
MFRD MANUFACTURED
MGD MILLION GALLONS PER DAY
MG/L MILLIGRAMS PER LITRE
MIN MINIMUM, MINUTE
MJ MECHANICAL JOINT
MLLW MEAN LOWER LOW WATER
MLSS MIXED LIQUOR SUSPENDED SOLIDS
M.O. MASONRY OPENING
N_________________________________
N NORTH
NA NONAUTOMATIC
NACHSODIUM HYDROXIDE
NEG NEGATIVE
NF NONFUSED
NIC NOT IN CONTRACT
NIS NOT IN SERVICE
NOX NITRATES AND NITRITES
NPSH NET POSITIVE SUCTION HEAD
NPT NATIONAL PIPE THREAD
NPW NON POTABLE WATER
NS NEAR SIDE
NTS NOT TO SCALE
O_________________________________
OC ON CENTER
OF OUTSIDE FACE
O.FO.I. OWNER FURNISHED-OWNER INSTALLED
OIS OPERATOR INTERFACE SYSTEM
OL OVERLOAD
ORF ODOR REMOVAL FILTER
ORT ODOR REDUCTION TOWER
OS OPEN SHELVING
OSC ODOR SCRUBBER
P_________________________________
P PUMP
PC PIPE COUPLING
PCC PLANT CONTROL CENTER
PCP PLAIN CONCRETE PIPE
PD PUMPED DRAIN
PE PLAIN END
P/E PNEUMATIC/ELECTRIC
PIVC POINT OF INTERSECTION ON VERTICAL CURVE
PL PROPERTY LINE
PLC PROGRAMMABLE LOGIC CONTROLLER
PLYWD PLYWOOD
POL POLYMER
POP PNEUMATIC OPERATOR
PP POWER POLE
PPD POUNDS PER DAY
PRES PRESSURE
PRL PARALLEL
PRV PRESSURE REDUCING VALVE
PRS PRESSURE REDUCING STATION
PSIA POUNDS PER SQUARE INCH ABSOLUTE
PSIG POUNDS PER SQUARE INCH GAGE
PT PRESSURE TREATED
PVC POLYVINYL CHLORIDE
PVT PAVEMENT
PW POTABLE WATER
PWWF PEAK WET WEATHER FLOW
Q_________________________________
Q RATE OF FLOW
QCPLG QUICK COUPLING
R_________________________________
R RADIUS
RCR RECORDER
REC RECEIVER
RECDRECEIVED
RED REDUCER
REG REGULATOR
REINF REINFORCEMENT
RGS RIGID GALVANIZED STEEL
RL REDUCED LEVEL
ROW RIGHT OF WAY
REQ'D REQUIRED
RPM REVOLUTIONS PER MINUTE
RS RAW SEWAGE
RT RIGHT
RTU REINFORCED THERMOSET PLASTIC
RV RELIEF VALVE
RWL RAINWATER LEADER
R/W REINFORCED WITH
S _________________________________
S SOUTH
SA CAUSTIC SODA ASH
SCH SCHEDULE
SD STORM DRAIN
SDMH STORM DRAIN MAN HOLE
SE SEWER EFFLUENT
SEL SELECTOR
SG SLUICE GATE
SIM SIMILAR
SL SLOPE
SN SUPERNATENT
SP STATIC PRESSURE
SPEC SPECIFICATION
SPG SPACING
SO2 SULFER DIOXIDE
SPRT SUPPORT
SR SPEED REDUCER
SS STAINLESS STEEL
SSMH SANITARY SEWER MANHOLE
STA STATION
STD STANDARD
STM STEAM
SUB SUBSTITUTE
SVC SERVICE
SWB SWITCHBOARD
SYM SYMMETRICAL
T _________________________________
TD TANK DRAIN
TDH TOTAL DYNAMIC HEAD
THK THICK
TOA TEST-OFF-AUTO
TOB TOP OF BANK
TOC TOP OF CURB
TOCN TOP OF ORGANIC CARBON
TOCR TOP OF CONCRETE
TOW TOP OF WALL
TP TANGENT POINT
TPG TOPPING
TPLX TRIPLEXED
TSS TOTAL SUSPENDED SOLIDS
TYP TYPICAL
U_________________________________
UL ULTIMATE LOAD
UN UNION
UNO UNLESS NOTED OTHERWISE
UP UTILITY POLE
US UTILITY STATION
UV ULTRAVIOLET
V_________________________________
V VOLT
VAR VARIABLE
VC VERTICAL CURVE
VCP VITRIFIED CLAY PIPE
VP VAPER PRESSURE
VSC VARIABLE SPEED COUPLING
VTR VENT THROUGH ROOF
W_________________________________
W WEST, WITH
WAT POTABLE WATER
W/O WITHOUT
WC WATER COLUMN
WF WIDE FLANGE
WG WASTE GAS
WM WATER METER
WS WATER SURFACE
WSE WATER SURFACE ELEVATION
WSTP WATERSTOP
WT WATERTIGHT
WWF WELDED WIRE FABRIC, WET WEATHER FLOW
X_________________________________
XLP CROSSED LINKED POLYTHYLENE
XP EXPLOSION PROOF
Y_________________________________
YCO YARD CLEANOUT
SYMBOL LEGEND
SANITARY SEWER MANHOLE
STORM DRAIN MANHOLE
CATCH BASIN
WATER VALVE
WATER METER
FIRE HYDRANT
CLEANOUT
POWER POLE
GUY ANCHOR
POWER PEDESTAL
TELEPHONE PEDESTAL
SURVEY MARKER
TEE/CROSS FITTING
ELBOW FITTING
REDUCER FITTING
MECHANICAL JOINT ADAPTER
LINETYPE LEGEND
WATER LINE
STORM DRAIN
SANITARY SEWER
ELECTRICAL
OVER HEAD LINE
TELEPHONE LINE
GAS LINE
TREELINE
EDGE OF PAVEMENT
RIGHT OF WAY
MAJOR CONTOURS
MINOR CONTOURS
FENCELINE
HATCH LEGEND
CONCRETE
PAVEMENT
NATURAL GROUND
WETLANDS
BUILDING
GRANULAR MATERIALS
(CRUSHED ROCK,
GRAVEL, ETC.)
co
SYMBOL LEGEND
SANITARY SEWER MANHOLE
STORM DRAIN MANHOLE
CATCH BASIN
WATER VALVE
WATER METER
FIRE HYDRANT
CLEANOUT
POWER POLE
GUY ANCHOR
POWER PEDESTAL
TELEPHONE PEDESTAL
TEE/CROSS FITTING
LINETYPE LEGEND
WATER LINE
STORM DRAIN
SANITARY SEWER
ELECTRICAL
OVER HEAD LINE
TELEPHONE LINE
GAS LINE
MAJOR CONTOURS
MINOR CONTOURS
DEMO
HATCH LEGEND
CONCRETE
PAVEMENT
GRANULAR MATERIALS
(CRUSHED ROCK,
GRAVEL, ETC.)
co
GRADING LEGEND
EXISTING FEATURE LEGEND NEW FEATURE LEGEND
T E
MB
LAT
ELBOW FITTING
REDUCER FITTING
MECHANICAL JOINT ADAPTER
MAILBOX
AIR RELEASE VALVE
BLOW OFF VALVE
ANCHOR WALL
SERVICE LATERAL CROSSING
TELEPHONE CROSSING
POWER CROSSING
WATERLINE CROSSING
SANITARY SEWER CROSSING
STORM DRAIN CROSSING
TREE/SHRUB
SIGN
MAIL BOX
AIR RELEASE VALVE
BLOW OFF VALVE
SERVICE LATERAL CROSSING
TELEPHONE CROSSING
POWER CROSSING
WATERLINE CROSSING
SANITARY SEWER CROSSING
STORM DRAIN CROSSING
TREE/SHRUB
SIGN
TEL
ELE
WTR
MB
W wv
SS
SD
T E
LAT
TEL
ELE
WTR
SS
SD
W
CUT OR FILL SLOPE-ARROWS
POINT DOWN SLOPE
GRADING SLOPE:
2 HORIZONTAL: 1 VERTICAL
FINISH GRADE
SPOT ELEVATION 210.0
GRADING LEGEND
210.0
EXISTING GRADE
SPOT ELEVATION
2:1
AutoCAD SHX Text
LEGEND AND ABBREVIATIONS
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text H
AutoCAD SHX Text Y
AutoCAD SHX Text D
AutoCAD SHX Text H
AutoCAD SHX Text Y
D
D
AT
E
D
ES
C R
IP
TI
O N
BY
D es ig ne d By
D ra w n By
C he ck ed B y:
D at e Sh ee t N o.
Pr oj ec t N o:
C oo s Ba y, O re go n
E St re et w w w .c iv ilw es t.c om
1-
6-
D
AT
E:5 /1
9/
F
IL
E:S :\2
M is c Pr iv at e En gi ne er in g W or k\
-3
S ta te o f O re go n
- S ou th S lo ug h En tra nc e an d R oa dw ay Im pr ov em en ts \0
D es ig n Se rv ic es \C
AD
\2
4-
FI
BE
R E
XH
IB
IT
.d w g
R
EG I N
E
N
11, S
PE
89522PE
OREGON
E
0SEAN D A L LOYD
RENEWS: 12/31/26
REG
I STERED PROFESS I ONAL
E N
G3
SO
U
TH
S
LO
U
G H
E N
TR
AN
C E
AN
D
R O
AD
W
AY
IM
PR
O
VE
M
EN
TS
O R
EG
O
N D
EP
T.
O F
ST
AT
E
LA
N D
S
C
SK
C
SK
-3
MAY 2025
SE
VE
N
D
EV
IL
S
R D
, C H
AR
LE
ST
O
N , O
R
GENERAL NOTES: HDD NOTES:
1. THE CONTRACTOR SHALL CONTACT 'ONE
CALL' FOR UTILITY LOCATES PRIOR TO
EXCAVATION. (1-800-332-2344)
2. CIVIL WEST ENGINEERING MAKES NO
REPRESENTATION OF THE EXISTENCE
OR NON-EXISTENCE OF UTILITIES. IT IS
THE RESPONSIBILITY OF THE
CONTRACTOR TO COMPLY WITH THE
PROVISIONS OF ORS 757.541 TO 757.571,
WHICH REQUIRES THE CONTRACTOR TO
NOTIFY UTILITIES AT LEAST 48 HOURS
BUT NO MORE THAN 10 BUSINESS DAYS
PRIOR TO ANY EXCAVATION. THE
CONTRACTOR WILL BE RESPONSIBLE
FOR ANY DAMAGE RESULTING FROM THE
DISRUPTION OF SERVICE CAUSED BY
CONSTRUCTION ACTIVITIES.
3. THE LOCATION AND DEPTH OF EXISTING
SITE FEATURES SHOWN ON THESE
DRAWINGS ARE APPROXIMATE ONLY.
4. TREES, BUSHES, AND SHRUBS MAY NOT
BE SPECIFICALLY OR INDIVIDUALLY
INDICATED ON THE DRAWINGS BUT MAY
EXIST WITHIN THE CONSTRUCTION
CORRIDOR.
5. ALL MATERIALS AND WORKMANSHIP
SHALL CONFORM TO THE LATEST
EDITION OF THE OREGON STANDARD
SPECIFICATIONS (OSS), THE AMERICAN
PUBLIC WORKS ASSOCIATION (APWA), AS
WELL AS THE PROJECT DESIGN
SPECIFICATIONS AND DRAWINGS. THESE
DRAWINGS SHALL BE COORDINATED
AND USED IN CONJUNCTION WITH THE
TECHNICAL SPECIFICATIONS AND
APPROVED SUBMITTALS.
6. ALL WORK SHALL BE COMPLETED IN
ACCORDANCE TO THE OREGON FOREST
PRACTICES ACT, AS APPLICABLE.
7. THE CONTRACTOR SHALL OBTAIN OR
VERIFY THAT REQUIRED PERMITS (ODFW
& OTHERS) ARE IN PLACE OR OBTAIN
PERMITS PRIOR TO STARTING
CONSTRUCTIONS, AND SHALL CALL FOR
INSPECTIONS IN ACCORDANCE WITH
SAID PERMITS AS REQUIRED BY THE
PERMITS.
8. THE CONTRACTOR AND/OR
SUB-CONTRACTOR SHALL HAVE A
MINIMUM OF ONE (1) SET OF APPROVED
CONSTRUCTION PLANS ON THE JOB AT
ALL TIMES DURING CONSTRUCTION
PHASES.
9. THE DRAWINGS ARE INTENDED TO SHOW
THE GENERAL CHARACTER AND EXTENT
OF THE PROJECT AND ARE NOT
INTENDED TO SHOW ALL DETAILS OF
THE WORK. USE DETAILS MARKED
"TYPICAL" WHEREVER THEY APPLY.
10.THE CONTRACTOR IS RESPONSIBLE
FOR COORDINATING DETAILS AND
ACCURACY OF THE WORK, FOR
CONFIRMING AND CORRELATING ALL
QUANTITIES AND DIMENSIONS, FOR
SELECTING FABRICATION PROCESSES,
FOR TECHNIQUES OF ASSEMBLY, AND
FOR PERFORMING WORK IN A SAFE AND
SECURE MANNER. CONTRACTOR SHALL
COORDINATE ANY REQUIRED
INSPECTIONS.
11.CONTRACTOR SHALL PROVIDE
REASONABLE ACCESS DURING THE
PROJECT CONSTRUCTION, AND
COORDINATE WITH EXISTING
TENANTS/ADJACENT OWNER'S IN
RELATION TO SUCH ACCESS, AS CAN
SAFELY BE ALLOWED. WORK SHALL
GENERALLY BE SCHEDULED TO PROVIDE
ACCESS TO TENANTS AND CUSTOMERS
AS MUCH AS REASONABLY ALLOWED
DURING NORMAL BUSINESS HOURS.
CONTRACTOR SHALL COORDINATE AND
FACILITATE ACCESS FOR OTHER
TRADES, UTILITIES AND REGULATING
AGENCIES. ACCESS FOR VISITORS AND
BUSES MUST BE MAINTAINED AT ALL
TIMES.
12.IN CASE OF DISCREPANCIES BETWEEN
THE GENERAL NOTES, SPECIFICATIONS
PLAN/DETAILS, OR REFERENCE
STANDARDS, THE ENGINEER SHALL
DETERMINE WHICH SHALL GOVERN.
DISCREPANCIES SHALL BE BROUGHT TO
THE ATTENTION OF THE ENGINEER
BEFORE PROCEEDING WITH THE WORK.
13.THE CONTRACTOR SHALL VERIFY ALL
DIMENSIONS AND CONDITIONS AT THE
SITE. CONFLICTS BETWEEN THE
DRAWING AND ACTUAL SITE CONDITIONS
SHALL BE BROUGHT TO THE ATTENTION
OF THE ENGINEER BEFORE PROCEEDING
WITH THE WORK.
14.ALTERNATE PRODUCTS OF SIMILAR
STRENGTH, NATURE AND FORM FOR
SPECIFIED ITEMS MAY BE SUBMITTED
WITH ADEQUATE TECHNICAL
DOCUMENTATION TO THE ENGINEER
FOR REVIEW. ALTERNATE MATERIALS
THAT ARE SUBMITTED WITHOUT
ADEQUATE TECHNICAL DOCUMENTATION
OR THAT SIGNIFICANTLY DEVIATE FROM
THE DESIGN INTENT OF MATERIALS
SPECIFIED MAY BE RETURNED WITHOUT
REVIEW. ALTERNATES THAT REQUIRE
SUBSTANTIAL EFFORT TO REVIEW WILL
NOT BE REVIEWED UNLESS AUTHORIZED
BY THE OWNER.
15.MATERIALS MARKED FOR REMOVAL
SHALL BE HAULED OFF SITE AND
DISPOSED OF. THE CONTRACTOR SHALL
OBTAIN THE DISPOSAL SITE LOCATION(S)
WITH THE STATE.
16.DO NOT SCALE DRAWINGS.
17.THE CONTRACTOR IS RESPONSIBLE
FOR THE MEANS AND METHODS OF
CONSTRUCTION AND ALL JOB RELATED
SAFETY STANDARDS SUCH AS OSHA AND
DOSH (DEPARTMENT OF OCCUPATIONAL
SAFETY AND HEALTH). CONTRACTOR IS
RESPONSIBLE TO ADHERE TO OSHA
REGULATIONS.
18.EXCAVATIONS SHOULD OCCUR DURING
DRY WEATHER. IF EXCAVATED SLOPES
ARE TO BE EXPOSED TO RAIN EVENTS
OR GROUND WATER IS ENCOUNTERED,
CONTRACTOR SHALL STOP WORK AND
CONTACT ENGINEER FOR DIRECTION.
19.THE CONTRACTOR IS RESPONSIBLE
FOR THE STRENGTH AND STABILITY OF
THE EARTHWORK DURING
CONSTRUCTION AND SHALL PROVIDE
TEMPORARY SHORING, BRACING AND
OTHER ELEMENTS REQUIRED TO
MAINTAIN STABILITY UNTIL THE SITE
GRADING IS COMPLETE. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO BE
FAMILIAR WITH THE WORK REQUIRED IN
THE CONSTRUCTION DOCUMENTS AND
REQUIREMENTS FOR EXECUTING IT
PROPERLY.
20.IT IS RECOMMENDED THAT A
PROFESSIONAL ENGINEER BE PRESENT
TO OBSERVE CUT/FILL OPERATIONS,
AND TO PROVIDE EVALUATION OF SOILS
ENCOUNTERED DURING EXCAVATION.
21.INSTALL EROSION & SEDIMENT
CONTROL BEST MANAGEMENT
PRACTICES PRIOR TO COMMENCING ANY
EXCAVATION OR EROSIVE ACTIVITIES.
REFER TO ODOT STANDARD DETAILS
6000-6017 AND SHEET D1 FOR EROSION
AND SEDIMENT CONTROL DETAILS.
22.NATIVE MATERIALS, STOCKPILES, AND
WASTE MATERIALS AT THE SITE SHALL
BE SLOPED FOR DRAINAGE AND
STABILITY. ALL EXPOSED EXCAVATION
AREAS AND WASTE MATERIALS SHALL BE
GRASS SEEDED, FERTILIZED, AND
COVERED WITH STOCKPILED TOPSOIL
ACCORDING TO THE DETAILS ON SHEET
D1.
23.THE CONTRACTOR SHALL REPLACE
AND RESTORE AREAS NOT SCHEDULED
FOR CONSTRUCTION TO THEIR ORIGINAL
CONDITION AND TO THE APPROVAL OF
THE OWNER'S REPRESENTATIVE. GRASS
SEED AND STOCKPILED TOPSOIL SHALL
BE APPLIED TO ALL DISTURBED &
EXPOSED AREAS. EXPOSED CUT AND
FILL SLOPES TO BE SEEDED AND
PROTECTED WITH STOCKPILED TOPSOIL.
24.CONTRACTOR SHALL FURNISH AND
INSTALL EQUIPMENT TO HAUL AND
PLACE WATER DURING SOIL DISPOSAL
EMBANKMENT CONSTRUCTION. AN
ADEQUATE SUPPLY OF WATER SHALL BE
MAINTAINED AT ALL TIMES.
25.DUST SHALL BE MINIMIZED TO THE
MAXIMUM EXTENT PRACTICABLE,
UTILIZING ALL MEASURES NECESSARY.
26.OIL SPILL RESPONSE MATERIALS SHALL
BE ON SITE BEFORE THE WORK BEGINS.
27.ELEVATIONS ARE IN LOCAL DATUM.
28.CONTOUR LINES ARE APPROXIMATE
AND BASED ON BEST AVAILABLE
INFORMATION. CONTRACTOR SHALL
OBTAIN WRITTEN PERMISSION FROM
PRIVATE LAND OWNERS PRIOR TO
ENTERING PRIVATE PROPERTY.
29.THE CONTRACTOR SHALL CAREFULLY
MAINTAIN BENCHMARKS, PROPERTY
CORNERS, MONUMENTS, AND OTHER
REFERENCE POINTS. IF SUCH POINTS
ARE DISTURBED OR DESTROYED BY THE
CONSTRUCTION ACTIVITIES, THE
CONTRACTOR SHALL NOTIFY THE
ENGINEER AND PAY FOR THEIR
REPLACEMENT BY EMPLOYING A
PROFESSIONAL LAND SURVEYOR TO
RESET PROPERTY CORNERS AND OTHER
SUCH MONUMENTS.
30.CONTRACTOR IS RESPONSIBLE FOR
PRESERVATION AND/OR PERPETUATION
OF ALL EXISTING SURVEY MONUMENTS
AND SURVEY CONTROL POINTS AT NO
COST TO THE OWNER. CONTRACTOR
SHALL PROVIDE A MINIMUM OF 10
WORKING DAYS' NOTICE TO ENGINEER
PRIOR TO DISTURBANCE OR REMOVAL
OF EXISTING MONUMENTS.
31.ALL PERMANENTLY INSTALLED
MATERIALS MUST BE SOURCED IN
ACCORDANCE WITH THE BUILD AMERICA
BUY AMERICA ACT (BABA) AND BUY
AMERICA
NOTES
E
T
T
E
10+00
11+00
12+00
13+00 13+26
50+00
+0
52+00
52+48
R
EV
D
AT
E
D
ES
C R
IP
TI
O N
BY
D es ig ne d By
D ra w n By
C he ck ed B y:
D at e Sh ee t N o.
Pr oj ec t N o:
C oo s Ba y, O re go n
E St re et w w w .c iv ilw es t.c om
1-
6-
D
AT
E:5 /1
9/
F
IL
E:S :\2
M is c Pr iv at e En gi ne er in g W or k\
-3
S ta te o f O re go n
- S ou th S lo ug h En tra nc e an d R oa dw ay Im pr ov em en ts \0
D es ig n Se rv ic es \C
AD
\2
4-
FI
BE
R E
XH
IB
IT
.d w g
R
EG I N
E
N
11, S
PE
89522PE
OREGON
E
0SEAN D A L LOYD
RENEWS: 12/31/26
REG
I STERED PROFESS I ONAL
E N
C1
SO
U
TH
S
LO
U
G H
E N
TR
AN
C E
AN
D
R O
AD
W
AY
IM
PR
O
VE
M
EN
TS
O R
EG
O
N D
EP
T.
O F
ST
AT
E
LA
N D
S
C
SK
C
SK
-3
MAY 2025
SE
VE
N
D
EV
IL
S
R D
, C H
AR
LE
ST
O
N , O
R
N
1 FIBER OPTIC INSTALLATION
C1
M A
TC
H
LIN
E
SEE SH
EET
C
INSTALL 4" HDPE CONDUIT
FOR FIBER LINE AT 5'
OFFSET FROM EXISTING
PAVEMENT (TYPICAL)
(INSTALLATION TO OCCUR
AS PART OF PHASE 1)
INSTALL PULLBOX FOR FIBER
LINE,
APPROX LID ELEVATION: 375'
SEE
PULL BOX DETAIL
D1
EXISTING COMM AND POWER LINES
D
EV
IL
S R
D
APPROX 4'X8' BORE
PIT LOCATION
APPROX 4'X8' BORE
PIT LOCATION
INSTALL PULL BOX FOR
FIBER LINE,
APPROX LID ELEVATION: 345'
SEE
PULL BOX DETAIL
D1
NEW UTILITY
VAULT, SEE UTILITY VAULT DETAIL
D1
EXISTING 400a 120/240V
SERVICE APPROX 4'X8' BORE
PIT LOCATION
NOTE: ALL OTHER IMPROVEMENTS SHALL BE COMPLETED DURING PHASE II OF THE PROJECT
EXISTING
TELECOMMUNICATIONS
PEDESTAL
NEW UTILITY VAULT
EXTEND SERVICE
CONNECTION AS
SHOWN
COORDINATE WITH
ZIPLY FOR HIGH-SPEED
INTERNET CABLE.
OWNER TO PROVIDE 4"
HDPE CONDUIT PIPING
AND 4 PULL BOXES.
INSTALL 2" HDPE CONDUIT
FOR FIBER LINE FROM
PULL BOX TO FUTURE
GATE LOCATION
TERMINATE 2" HDPE CONDUIT
FOR SECONDARY FIBER RUN
IN PULL BOX
AutoCAD SHX Text
FIBER OPTIC INSTALLATION
AutoCAD SHX Text
%%U PLAN SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1"=40'
AutoCAD SHX Text
AutoCAD SHX Text
E T E
VISITOR CENTER
INSTALL PULLBOX FOR FIBER
LINE,
APPROX LID ELEVATION: 330.5'
SEE
R
EV
D
AT
E
D
ES
C R
IP
TI
O N
BY
D es ig ne d By
D ra w n By
C he ck ed B y:
D at e Sh ee t N o.
Pr oj ec t N o:
C oo s Ba y, O re go n
E St re et w w w .c iv ilw es t.c om
1-
6-
D
AT
E:5 /1
9/
F
IL
E:S :\2
M is c Pr iv at e En gi ne er in g W or k\
-3
S ta te o f O re go n
- S ou th S lo ug h En tra nc e an d R oa dw ay Im pr ov em en ts \0
D es ig n Se rv ic es \C
AD
\2
4-
FI
BE
R E
XH
IB
IT
.d w g
R
EG I N
E
N
11, S
PE
89522PE
OREGON
E
0SEAN D A L LOYD
RENEWS: 12/31/26
REG
I STERED PROFESS I ONAL
E N
C2
SO
U
TH
S
LO
U
G H
E N
TR
AN
C E
AN
D
R O
AD
W
AY
IM
PR
O
VE
M
EN
TS
O R
EG
O
N D
EP
T.
O F
ST
AT
E
LA
N D
S
C
SK
C
SK
-3
MAY 2025
SE
VE
N
D
EV
IL
S
R D
, C H
AR
LE
ST
O
N , O
R
N
1 FIBER OPTIC INSTALLATION
C2
M A
TC
H
L
IN
E
SE
E
SH
EE
T
C
PROVIDE NEW
INTERNET SERVICE
TO EX. BLDG
INSTALL 4" HDPE CONDUIT
FOR FIBER LINE
(INSTALLATION TO OCCUR
AS PART OF PHASE 1)
CONDUIT
BUILDING
PENETRATION
TO BE
INSTALLED
FROM
PULLBOX,
SEE
WALL PENETRATION DETAIL
D1
EXISTING COMM AND POWER LINES
NOTE: ALL OTHER IMPROVEMENTS SHALL BE COMPLETED DURING PHASE II OF THE PROJECT
APPROX 4'X8' BORE
PIT LOCATION
PULL BOX DETAIL
D1
PULL BOX DETAIL
D1
APPROX 4'X8' BORE
PIT LOCATION
ITEM QUANTITY
2" HDPE CONDUIT 1170 LF
PULL BOXES 4
UTILITY VAULT 1
4'X8' BORING PIT 5
BUILDING
PENETRATION
USE TYPE LB CONDUIT BODY TO TRANSITION
BETWEEN EXTERIOR AND INTERIOR CONDUITS.
FIBER CABLE TO TERMINATE IN CEILING ABOVE
THE VISITOR CENTER CLASSROOM IN
WALL-MOUNT HOUSING
AutoCAD SHX Text
FIBER OPTIC INSTALLATION
AutoCAD SHX Text
%%U PLAN SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1"=40'
AutoCAD SHX Text
AutoCAD SHX Text
D
AT
E
D
ES
C R
IP
TI
O N
BY
D es ig ne d By
D ra w n By
C he ck ed B y:
D at e Sh ee t N o.
Pr oj ec t N o:
C oo s Ba y, O re go n
E St re et w w w .c iv ilw es t.c om
1-
6-
D
AT
E:5 /1
9/
F
IL
E:S :\2
M is c Pr iv at e En gi ne er in g W or k\
-3
S ta te o f O re go n
- S ou th S lo ug h En tra nc e an d R oa dw ay Im pr ov em en ts \0
D es ig n Se rv ic es \C
AD
\2
4-
FI
BE
R E
XH
IB
IT
.d w g
R
EG I N
E
N
11, S
PE
89522PE
OREGON
E
0SEAN D A L LOYD
RENEWS: 12/31/26
REG
I STERED PROFESS I ONAL
E N
D1
SO
U
G H
S
LO
U G
H E
N
TR
AN
C
E
AN
D R
O
AD
W
AY
IM
PR
O
VE
M
EN
TS
O R
EG
O
N D
EP
T.
O F
ST
AT
E
LA
N D
S
C
SK
C
SK
-2
MAY 2025
SE
VE
N
D
EV
IL
S
R D
, C H
AR
LE
ST
O
N , O
R
PULL BOX DETAIL
D1
SCALE: NTS
WALL PENETRATION DETAIL
D1
SCALE: NTS
HOLE-DRILL CEDAR
SHINGLES AS NECESSARY
FOR INSTALLATION OF LB
CONDUIT
LB CONDUIT
CEDAR
SHINGLES
8" EXTERNAL
PLYWOOD
VAPOR
BARRIER
8" GYPSUM
BOARD
R19
FIBERGLASS
INSTALLATION
4"
CONDUIT
ALL WEATHER SEALANT
WITH 18" BEAD APPLIED AT
INTERFACE OF SHINGLE
AND LB CONDUIT
DUCT SEAL
1/4" THICK
UTILITY VAULT DETAIL
D1
SCALE: NTS
KNOCKOUT
FOR 4"
CONDUIT
LOCKING CAST IRON COVER
DETAILS
| Sheets and Views |
| Cover |
File details come from the government source that posted it. Updated .