About this file

This document appears to be Attachment B Plans and Drawings related to ITB 10088 Utility System Improvements at Beverly Beach State Park, a state and local contract opportunity in Oregon. The purpose of this Invitation to Bid is to establish a contract for utility system improvements at the Beverly Beach State Park, including site preparation, demolition, and construction of water, sewer, and electrical utilities. The jurisdictions involved are Lincoln County and Newberg City. The contract term and any renewal options are not specified.

The document does not provide details on pricing terms, set asides, incumbents, funding requirements and sources, or other salient information. It appears to solely contain plans and drawings related to the utility system improvements project.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N at u re

D is co ve ry

5/

/2

3:

:4

P

M C

W es te ch \D

W G

\B ev er ly

B ea ch U til S ys Im pr

3.

.0 \C iv il\

P lo ts \C

5.

1-

5.

K

IO

S K

.d w g

(C 5.

2 t ab

N at u re

D is co ve ry

5/

/2

3:

:4

P

M C

W es te ch \D

W G

\B ev er ly

B ea ch U til S ys Im pr

3.

.0 \C iv il\

P lo ts \C

5.

1-

5.

K

IO

S K

.d w g

(C 5.

3 t ab

6446 Fairway Ave. SE, Suite 220 Salem, OR 97306

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

Abbreviations

A AMPERE

AC ALTERNATING CURRENT, AIR CONDITIONING UNIT

AHJ AUTHORITY HAVING JURISDICTION

AI ANALOG INPUT

AIC AVAILABLE INTERRUPTING CAPACITY

AF AMPERE FRAME / AMPERE FUSED

AFC ABOVE FINISHED CEILING

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

AO ANALOG OUTPUT

ARMS ARC FLASH REDUCTION MAINTENANCE SYSTEM

AT AMPERE TRIP

AV AUDIO / VIDEO

AWG AMERICAN WIRE GAUGE

BAS BUILDING AUTOMATION SYSTEM

BFG BELOW FINISHED GRADE

BLDG BUILDING

C CONDUIT

CAT CATEGORY

CB CIRCUIT BREAKER

CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED

CFOI CONTRACTOR FURNISHED, OWNER INSTALLED

CKT CIRCUIT

CPT CONTROL POWER TRANSFORMER

CR CONTROL RELAY

CU COPPER

dB DECIBAL

DC DIRECT CURRENT

DI DIGITAL INPUT

DIM DIMENSION

DIV DIVISION

DO DIGITAL OUTPUT

DTL DETAIL

DWG DRAWING

EIP ETHERNET IP

EL ELEVATION

EMT ELECTRICAL METALLIC TUBING

EOLR END OF LINE RESISTOR

ETR EXISTING DEVICE SHALL REMAIN

FACP FIRE ALARM CONTROL PANEL

FF FINISH FLOOR

FLA FULL LOAD AMPERES

FT FOOT, FEET

FBO FURNISHED BY OTHERS

G, GND GROUND

GFCI GROUND FAULT CIRCUIT INTERRUPTER

HH HAND HOLE

HP HORSEPOWER

ID IDENTIFICATION

IDC INITIATING DEVICE CIRCUIT

IDF INTERMEDIATE DISTRIBUTION FRAME

IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS

IG ISOLATED GROUND

IT INFORMATION TECHNOLOGY

JB JUNCTION BOX

KAIC THOUSAND AMPS INTERRUPTING CURRENT

KCMIL THOUSAND CIRCULAR MILS

KVA KILOVOLT-AMPERE

KW KILOWATT

LAN LOCAL AREA NETWORK

LED LIGHT EMITTING DIODE

LS LIMIT SWITCH

LSI ELECTRONIC TRIP UNIT ADJUSTABLE LONG TIME DELAY, SHORT TIME

DELAY, INSTANTANEOUS TRIP

LSIG ELECTRONIC TRIP UNIT WITH ADJUSTABLE LONG TIME DELAY, SHORT TIME

DELAY, INSTANTANEOUS TRIP, AND GROUND FAULT

LV LOW VOLTAGE

MCA MINIMUM CIRCUIT AMPACITY

MCC MOTOR CONTROL CENTER

MCP MOTOR CIRCUIT PROTECTOR

MDF MAIN DISTRIBUTION FRAME

MHz MEGAHERTZ

MISC MISCELLANEOUS

MLO MAIN LUGS ONLY

MOCP MAXIMUM OVERCURRENT PROTECTION

N NEUTRAL

NAC NOTIFICATION APPLIANCE CIRCUIT

N/A NOT APPLICABLE

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

NEX REPLACE EXISTING WIRING DEVICE AND FACEPLATE WITH NEW.

BACK BOX AND CONDUIT SHALL REMAIN.

NL NIGHT LIGHT

NO NORMALLY OPEN

NTS NOT TO SCALE

OC ON CENTER

OFCI OWNER FURNISHED, CONTRACTOR INSTALLED

OFOI OWNER FURNISHED, OWNER INSTALLED

Ø PHASE

PB PULL BOX, PANIC BUTTON, PUSH BUTTON

PE PHOTE EYE

PNL PANEL

POE POWER OVER ETHERNET

PTZ PAN, TILT, ZOOM

RD LOCATION OF RELOCATED DEVICE / EQUIPMENT

REX REMOVE EXISTING DEVICE / EQUIPMENT

RF RADIO FREQUENCY

RFI REQUEST FOR INFORMATION

RR REMOVE AND RELOCATE EXISTING DEVICE / EQUIPMENT

SLC SIGNALING LINE CIRCUIT

SPD SURGE PROTECTION DEVICE

STD STANDARD

SW SWITCH

T/M THERMAL MAGNETIC CIRCUIT BREAKER

TBD TO BE DETERMINED

TV TELEVISION / MONITOR OUTLET

TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR

TYP TYPICAL

UH UNIT HEATER

UG UNDERGROUND

UL UNDERWRITERS LABORATORIES

UPS UNINTERRUPTIBLE POWER SUPPLY

UON UNLESS OTHERWISE NOTED

USB UNIVERSAL SERIAL BUS

V VOLTS, VOLTAGE

VA VOLT-AMPERE

VFD VARIABLE FREQUENCY DRIVE

W WATT, WIRE

WAN WIDE AREA NETWORK

WAP WIRELESS ACCESS POINT

WI-FI WIRELESS FIDELITY

W/ WITH

W/O WITHOUT

WP WEATHERPROOF

XFMR TRANSFORMER

Y WYE

+72 MOUNTING UNITS EXPRESSED IN INCHES TO CENTERLINE ABOVE

FINISHED FLOOR OR GRADE.

1P ONE POLE

2P TWO POLE

3P THREE POLE

4P FOUR POLE

Annotation

CONDUIT & CONDUCTOR CALLOUT. REFER TO

CONDUIT & CONDUCTOR SCHEDULE.

KEYED NOTE CALLOUT. REFER TO

CORRESPONDING SHEET KEYNOTES.

PXXX

XX

(E) INDICATES EXISTING EQUIPMENT TO REMAIN.

(D) INDICATES EXISTING EQUIPMENT TO BE

DEMOLISHED.

(N) INDICATES NEW EQUIPMENT.

XX

XX

KEYED NOTE CALLOUT. REFER TO

CORRESPONDING SHEET KEYNOTES.

KEYED NOTE CALLOUT. REFER TO

CORRESPONDING SHEET KEYNOTES.

MECHANICAL EQUIPMENT CALLOUT. REFER TO

MECHANICAL EQUIPMENT CONNECTION SCHEDULE.

XX-XX

X

EX.X DETAIL CALLOUT. REFER TO DETAIL AND SHEET AS

INDICATED ON CALLOUT.

FIXTURE MOUNTING CALLOUT. HEIGHT ABOVE

FINISHED FLOOR (A.F.F.)

XX'-XX"

XXXXX EQUIPMENT CALLOUT. REFER TO NEMA

CONNECTION SCHEDULE.

X

EX.XX SECTION CALLOUT. REFER TO SECTION AND SHEET

AS INDICATED ON CALLOUT.

(RP) INDICATES EXISTING EQUIPMENT TO REPLACED

WITH NEW.

ELEVATION CALLOUT. REFER TO ELEVATION AND

SHEET AS INDICATED ON CALLOUT.

EX.XX

(RR)/(RD) INDICATED EXISTING EQUIPMENT OR DEVICE TO BE

REMOVED AND REINSTALLED.

Electrical Abbreviations & Symbol Legend General Electrical Notes

1. ALL LIGHTING BRANCH CIRCUITS SHALL BE 2#10, 1#10G IN

3/4" CONDUIT, UON.

2. ALL 20-AMP RECEPTACLE AND HARDWIRED BRANCH

CIRCUITS SHALL BE 2#12, 1#12G IN 3/4" CONDUIT, UON.

3. ALL EXIT SIGNS SHALL BE WIRED TO THE LOCAL LIGHTING

BRANCH CIRCUIT AHEAD OF ALL SWITCHING.

4. PROVIDE 0-10V DIMMING CONDUCTORS TO ALL LUMINAIRES

WHICH ARE CONTROLLED BY 0-10V DIMMERS SHOWN ON

THE DRAWINGS.

UTILITY PRIMARY (MEDIUM VOLTAGE)

FEEDERS (OR LOW VOLTAGE)

Conduit Linetype

EXISTING CONDUIT

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

ELECTRICAL ABBREVIATIONS

AutoCAD SHX Text E0.1

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

Raceways

CONDUIT AND/OR CONDUCTORS INSTALLED ABOVE

GRADE, CONCEALED IN WALL OR CEILING SPACE.

CONDUIT TURNED DOWN.

CONDUIT AND/OR CONDUCTORS INSTALLED BELOW

GRADE, BELOW SLAB.

CONDUIT TURNED UP.

CONDUIT STUBBED AND CAPPED.

CONDUIT DIRECT CONNECTION TO EQUIPMENT.

FLEXIBLE CONNECTION TO EQUIPMENT.

CONDUIT / WIRING CONTINUATION.

HOMERUN TO PANELBOARD.

CABLE TRAY. SIZE AND TYPE AS INDICATED ON

DRAWINGS.

Drawing Symbol Variables

3 THREE WAY SWITCH.

4 FOUR WAY SWITCH.

#J QUANTITY OF JACKS AND HORIZONTAL CABLES.

AV MOUNTED ADJACENT TO SMARTBOARD.

C MOUNTED HORIZONTALLY AT 4" ABOVE

COUNTERTOP.

CL CLOCK.

DR DUAL RELAY.

E RED EMERGENCY SWITCH.

EL ELEVATOR RECALL.

LF LOW FREQUENCY.

LV LOW VOLTAGE SWITCH.

M MOTOR RATED TOGGLE SWITCH.

O INTEGRAL OCCUPANCY SENSOR.

P ADA PHONE, VERIFY HEIGHT WITH ARCHITECT /

OWNER.

TK MOUNTED IN TOE KICK OF CASEWORK.

TV MOUNTED ADJACENT TO TV AT 60" AFF, UON.

V VANDAL RESISTANT.

WG WIREGUARD.

WP WEATHERPROOF SWITCH.

Power Distribution

DUPLEX RECEPTACLE, MOUNTED AT 18" AFF, UON.

QUADPLEX RECEPTACLE, MOUNTED AT 18" AFF,

UON.

GFCI QUADPLEX RECEPTACLE, MOUNTED AT 18"

AFF, UON.

SWITCHED DUPLEX RECEPTACLE, MOUNTED AT 18"

AFF, UON.

NEMA SPECIAL RECEPTACLE, MOUNTED AT 18" AFF,

UON. NEMA CONFIGURATION AS INDICATED.

RECEPTACLE MOUNTED ON CEILING.

TAMPERPROOF DUPLEX RECEPTACLE, MOUNTED

AT 18" AFF, UON.

GFCI DUPLEX RECEPTACLE, MOUNTED AT 18" AFF,

UON.

PANELBOARD SURFACE MOUNT.

PANELBOARD FLUSH MOUNT.

MAIN DISTRIBUTION PANEL.

DISCONNECT SWITCH.

FUSED DISCONNECT SWITCH.

ENCLOSED CIRCUIT BREAKER.

COMBINATION STARTER.

FLOORBOX COMBINATION POWER & DATA.

FLOORBOX POWER.

POKETHRU COMBINATION POWER & DATA.

POKETHRU POWER.

POWER/DATA POLE.

SIMPLEX RECEPTACLE, MOUNTED AT 18" AFF, UON.

MOTOR CONTROL CENTER (MCC).

MOTOR CONTROL CENTER (MCC) TRANSITION.

UTILITY CT METER.

TAMPERPROOF QUADPLEX RECEPTACLE,

MOUNTED AT 18" AFF, UON.

CENTER HATCHED RECEPTACLE TO BE WIRED TO

EMERGENCY CIRCUIT.

Lighting

TROFFER LUMINAIRE, SURFACE OR RECESS

MOUNTED AS INDICATED ON THE DRAWINGS.

EMERGENCY BATTERY PACK LUMINAIRE, WALL OR

CEILING MOUNTED.

PENDANT MOUNTED LUMINAIRE.

BOLLARD LUMINAIRE.

SITE LUMINAIRE POLE MOUNTED. NUMBER OF

HEADS AS SHOWN.

TRACK LUMINAIRE.

WALL MOUNTED LUMINAIRE.

DOWNLIGHT LUMINAIRE, SURFACE, RECESS, OR

PENDANT MOUNTED AS INDICATED ON THE

DRAWINGS.

EXIT SIGN, WALL OR CEILING MOUNTED, SINGLE

FACE WITH DIRECTIONAL CHEVRONS AS SHOWN

ON DRAWINGS.

EXIT SIGN, WALL OR CEILING MOUNTED, DOUBLE

FACE WITH DIRECTIONAL CHEVRONS AS SHOWN

ON DRAWINGS.

UNDERCABINET LUMINAIRE.

LINEAR WALL MOUNTED LUMINAIRE.

SPOT LUMINAIRE.

HALF HATCHED LUMINAIRE TO BE WIRED TO

EMERGENCY CIRCUIT.

FULL HATCHED LUMINAIRE TO BE WIRED TO

NIGHTLIGHT CIRCUIT.

WALL WASH LUMINAIRE POINTED IN DIRECTION AS

SHOWN

One-Line Diagram

TRANSFER SWITCH, WITH FUSES OR BREAKERS AS

SHOWN ON DRAWINGS.

E

L

N

CIRCUIT BREAKER.

DRAWOUT CIRCUIT BREAKER.

ENCLOSED CIRCUIT BREAKER.

MOTOR STARTER CONTACT.

M CURRENT TRANSFORMER METER.

HTR

RA

BATT

HEATER.

REMOTE ANNUNCIATOR.

BATTERY CHARGER.

DISCONNECT SWITCH.

ENCLOSED DISCONNECT SWITCH.

FUSED DISCONNECT SWITCH.

ENCLOSED FUSED DISCONNECT SWITCH.

FUSE, RATING AS SHOWN ON DRAWINGS.

GENERATOR, CONFIGURATION AS SHOWN ON

DRAWING.

GROUND ROD.

GROUND.

MOTOR, RATED AS SHOWN ON DRAWINGS.

NEMA CONNECTION.

NAME

PANEL.

MINI POWER CENTER.NAME

SHUNT TRIP.

SURGE SUPPRESSION DEVICE.

DIGITAL METER.

SP

D

D /M

TRANSFORMER.

VARIABLE FREQUENCY DRIVE.

SOFT STARTER.

VFD

SS

ST

K

RX

ACCESS CONTROL - DOOR CONTACT. PROVIDE 3/4"

CONDUIT FROM DOOR FRAME TO ACCESSIBLE

CEILING OR SECURITY JUNCTION BOX AS SHOWN

ON THE DRAWINGS.

ACCESS CONTROL - ELECTRIC STRIKE. PROVIDE

3/4" CONDUIT FROM DOOR FRAME TO ACCESSIBLE

CEILING OR SECURITY JUNCTION BOX AS SHOWN

ON THE DRAWINGS.

ACCESS CONTROL - KEY PAD. PROVIDE 3/4"

CONDUIT FROM DOOR FRAME TO ACCESSIBLE

CEILING OR SECURITY JUNCTION BOX AS SHOWN

ON THE DRAWINGS.

ACCESS CONTROL - REQUEST TO EXIT. PROVIDE

3/4" CONDUIT FROM DOOR FRAME TO ACCESSIBLE

CEILING OR SECURITY JUNCTION BOX AS SHOWN

ON THE DRAWINGS.

SECURITY CAMERA - CEILING MOUNTED. PROVIDE

ONE (1) CAT6.

SECURITY CAMERA - WALL MOUNTED. PROVIDE

ONE (1) CAT6.

Access Control & Security

IS INTRUSION SENSOR - CEILING MOUNTED.

IS INTRUSION SENSOR - WALL MOUNTED.

ACCESS CONTROL - PANIC BUTTON.

ACCESS CONTROL - CARD READER. PROVIDE 3/4"

CONDUIT FROM DOOR FRAME TO ACCESSIBLE

CEILING OR SECURITY JUNCTION BOX AS SHOWN

ON THE DRAWINGS.

ACCESS CONTROL - MAGNETIC LOCK. PROVIDE 3/4"

CONDUIT FROM DOOR FRAME TO ACCESSIBLE

CEILING OR SECURITY JUNCTION BOX AS SHOWN

ON THE DRAWINGS.

S ACCESS CONTROL - SECURITY JUNCTION BOX.

SIZED AS RECOMMENDED BY SECURITY SYSTEM

MANUFACTURER.

CI ACCESS CONTROL - CAMERA / INTERCOM.

IK INTRUSION KEYPAD.

Switches

SINGLE POLE SWITCH - MOUNTED AT 42" AFF, UON.

MULTILEVEL SWITCH - MOUNTED AT 42" AFF, UON.

LOW VOLTAGE 0-10 VOLT DIMMING SWITCH -

MOUNTED AT 42" AFF, UON.

M OCCUPANCY SENSOR - CEILING OR WALL

MOUNTED.

PP OCCUPANCY SENSOR POWER PACK.

PHOTOCELL - CEILING OR WALL MOUNTED.

M

PC PC

ADA DOOR PUSHPLATE.

EMERGENCY STOP SWITCH, MUSHROOM HEAD.

PUSHBUTTON, SINGLE.

PUSHBUTTON, DOUBLE.

Low Voltage

ETHERNET OUTLET MOUNTED AT 18" AFF, UON.

COAXIAL OUTLET MOUNTED AT 18" AFF, UON.

PHONE OUTLET MOUNTED AT 18" AFF, UON.

LOW VOLTAGE OUTLET CEILING MOUNTED.

WIRELESS ACCESS POINT CEILING MOUNTED.

WIRELESS ACCESS POINT WALL MOUNTED.

FLOORBOX DATA.

POKETHRU DATA.

DIGITAL CLOCK.

Park Symbols

RV RV RECEPTACLE.

YURT SITE NUMBER. CONTRACTOR SHALL

TERMINATE CONDUCTORS ON EXISTING

DISCONNECT LOCATED AT SITE.

RV SITE NUMBER. CONTRACTOR SHALL

TERMINATE CONDUCTORS ON NEW OWNER

FURNISHED, CONTRACTOR INSTALLED RV

PEDESTAL WITH RECEPTACLE AT SITE.

CABIN SITE NUMBER.

TENT SITE NUMBER.

XXX

XXX

XXX

XXX

Miscellaneous

JUNCTION BOX (ROUND, SQUARE, OCTAGONAL).

THERMOSTAT.

RELAY.

CORD REEL.

MOTOR / EXHAUST FAN.

CEILING FAN.

UTILITY POLE.

WEATHERHEAD.

GROUND ROD.

GROUND ROD WITH TEST WELL.

SURFACE RACEWAY / WIREMOLD.

FIRE RATED BACKBOARD.

JJ J

T

R

U UTILITY EQUIPMENT.

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

ELECTRICAL SYMBOL LEGEND

AutoCAD SHX Text E0.2

AutoCAD SHX Text S

AutoCAD SHX Text S

S

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

24" Ø

# 4 HOOPS AT 12" O.C.

8 - # 5 EQUALLY SPACED

FINISHED

GRADE

6' -6

UNDISTURBED EARTH

INSTALL POLE WITH ANCHORS AND LEVELING

NUTS PROVIDED BY POLE MANUFACTURER.

PROVIDE POLE WITH HANDHOLE AND

INTERNAL GROUNDING STUD

PROVIDE 1" CHAMFER AT

TOP OF CONCRETE BASE

USE NON-SHRINK GROUT TO

COVER GAP AFTER LEVELING.

WALKWAY POLE

MOUNTED

LIGHTING BASE

101DETAIL NO.NTSSCALE:

HANDHOLE

ENCLOSURE

XXXDETAIL NO.NTSSCALE:

NATIVE BACKFILL

EXISTING EARTH

3/4" MINUS GRAVEL

COMPACTED EARTH

HANDHOLE

ENCLOSURE

6" M

IN

LID SHALL BE FLUSH

WITH FINISHED GRADE

FINISHED GRADE

ELECTRICAL CONDUITS

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

ELECTRICAL DETAILS (1 OF 2)

E0.5

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

NON-CONCRETE

ENCASED DUCTBANK

DETAIL

402DETAIL NO.NTSSCALE:

FINISHED GRADE

UNDISTRIBUTED EARTH

INSTALL CONDUITS

PER SCHEDULE, TYP.

NOTES:

1.TYPICAL EXCEPT AS SPECIFIED.

2. MAINTAIN A MINIMUM OF 12" SEPARATION BETWEEN POWER CONDUITS AND

CONTROL, TELECOMMUNICATION AND INSTRUMENTATION.

3. BACKFILL SHALL BE AS SPECIFIED IN SECTION 02226/312300.

3"

M

IN

S

EP

AR

AT

IO

N

, T

YP

3" MIN SEPARATION, TYP.

" M

IN

6" COVER OF SCREENED GRANULAR

BACKFILL SHALL SURROUND CONDUITS.

BACKFILL SHALL CONTAIN ONLY SOIL AND

ROCKS THAT WILL PASS THROUGH A

3/4" SIEVE. AND NO MORE THAN 15% OF

THE MATERIAL PASSES THROUGH A

NO. 200 MESH SIEVE.

3" M

IN

. B

ED

D

IN

G

SU

B

BA

SE

O F

SU

R

FA

C

E

NATIVE BACKFILL, FREE OF ROCKS AND

DEBRIS LARGER THAN 4" DIAMETER

TRENCH WARNING TAPE

(16130.T01/260533.T01)

COMPACTED EARTH

PROVIDE 6" MINIMUM OF 3/4" MINUS

GRAVEL BASE PER SECTION 02226/312300.

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

ELECTRICAL DETAILS (2 OF 2)

E0.6

GENERATOR MANUAL

TRANSFER SWITCH

MAIN SERVICE

DISCONNECT

MAIN SERVICE

DISCONNECT

6446 Fairway Ave. SE, Suite 220 Salem, OR 97306

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

SCALE:

TYPICAL ELECTRICAL KIOSK

FRONT ELEVATION1 NTS

SHEET KEY NOTES

5' -6

"6' -6

1. PROVIDE A STAINLESS STEEL NEMA 4X,

SERVICE ENTRANCE RATED MAIN

DISTRIBUTION PANELBOARD. REFERENCE

PANEL SCHEDULES FOR MORE DETAILS ON

RATINGS.

2. PROVIDE LIGHT SWITCH WEATHERPROOF

COVER.

3. GFCI RECEPTACLE WITH WEATHERPROOF

IN-USE METAL COVER.

4. PROVIDE STAINLESS STEEL METERBASE WITH

TEST SWITCH. PROVIDE METERBASE PER

UTILITIES REQUIREMENTS.

5. PROVIDE FIXTURE WITH SINGLE POLE LIGHT

SWITCH WITH WEATHERPROOF COVER FOR

CONTROL. PROVIDE KIOSK LUMINAIRE AS

SPECIFIED. REFERENCE SECTION 16512.E05.

6. RED BEACON LIGHT.

7. CONDUIT FOR GROUNDING ELECTRODE

SYSTEM. REFERENCE GROUNDING

ELECTRODE SCHEDULE.

8. REFERENCE THE CONDUIT SCHEDULES FOR

CONDUITS EXITING THE DISTRIBUTION

PANELS.

9. PROVISIONS FOR CONNECTION TO

TEMPORARY PORTABLE GENERATOR.

REFERENCE SECTION 16410.

10. REFERENCE CONDUIT SCHEDULES FOR

GROUNDING ELECTRODE CONDUCTOR SIZE.

11. FOR B-LOOP KIOSK AND C-LOOP LIFT STATION

KIOSK, PROVIDE 240VAC, 3Ø.

12. REFERENCE PANEL SCHEDULES FOR POWER

DISTRIBUTION.

13. C-LOOP LIFT STATION PUMP CONTROL PANEL.

14. STUB UP CONDUITS 2" ABOVE FINISHED

FLOOR. THE CABLES FOR THE PUMPS AND

INSTRUMENTS SHALL ROUTE FREE AIR TO

THE PUMP CONTROL PANEL.

15. THERE IS A 36" ENVELOPE AROUND THE

CONDUITS STUBBING UP FROM WET WELL

THAT IS A CLASS 1, DIVISION 2 HAZARDOUS

ZONE. MOUNT THE PUMP CONTROL PANEL 38"

TO BOTTOM OF PANEL ABOVE FINISHED

FLOOR.

16. INSTALL GENERATOR RECEPTACLE DIRECTLY

BELOW MANUAL TRANSFER SWITCH.

SCALE:

C-LOOP LIFT STATION ELECTRICAL KIOSK

FRONT ELEVATION2 NTS

5' -6

"6' -6

E

L

N

M

X LOOP

UTILITY TRANSFORMER

REFERENCE PANEL

SCHEDULES FOR

AVAILABLE FAULT

CURRENT AT EACH KIOSK

MAIN DISCONNECT

120/240VAC, 1Ø

200AF

200AT

42kAIC

MANUAL TRANSFER SWITCH

120/240VAC, 1Ø

200AS

TYPICAL PANELBOARD

120/240VAC, 1Ø

200A

SCALE:

TYPICAL

ELECTRICAL KIOSK ONE-LINE DIAGRAM3 NTS

MANUAL TRANSFER SWITCH SHALL BE

MOUNTED BEHIND PANELBOARD,

ON THE OTHER SIDE OF THE KIOSK.

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

KIOSK ELEVATION DETAILS

E0.7

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

POWER CONDUIT / CONDUCTOR SCHEDULE

CONDUIT ID

NO.

CONDUIT CONDUCTORS PER CONDUIT

FROM TO DESCRIPTION NOTES

QUANTITY SIZE UNGROUNDED GROUNDED GROUNDING CABLE SPARE

GENERAL SHEET NOTES

1. CONTRACTOR SHALL REFERENCE SECTION

16131 CONDUITS AND FITTINGS FOR CONDUIT

INSTALLATION REQUIREMENTS.

P100 2 2.0 INCH - - - - - UTILITY POLE #100988 PARK ENTRANCE UTILITY SWITCH - -

P101 2 2.0 INCH - - - - - PARK ENTRANCE UTILITY SWITCH C-LOOP UTILITY SWITCH INSTALL CONDUIT AT A DEPTH OF 4'. PROVIDE CONDUIT AND PULL ROPE PER

CLPUD REQUIREMENTS. INSTALL CONDUIT WITH 3' SWEEPS. -

P102 2 2.0 INCH - - - - - C-LOOP UTILITY SWITCH D-LOOP UTILITY SWITCH INSTALL CONDUIT AT A DEPTH OF 4'. PROVIDE CONDUIT AND PULL ROPE PER

CLPUD REQUIREMENTS. INSTALL CONDUIT WITH 3' SWEEPS. -

P103 2 2.0 INCH - - - - - D-LOOP UTILITY SWITCH E-LOOP UTILITY SWITCH INSTALL CONDUIT AT A DEPTH OF 4'. PROVIDE CONDUIT AND PULL ROPE PER

CLPUD REQUIREMENTS. INSTALL CONDUIT WITH 3' SWEEPS. -

P104 2 2.0 INCH - - - - - E-LOOP UTILITY SWITCH F-LOOP UTILITY SWITCH INSTALL CONDUIT AT A DEPTH OF 4'. PROVIDE CONDUIT AND PULL ROPE PER

CLPUD REQUIREMENTS. INSTALL CONDUIT WITH 3' SWEEPS. -

P105 2 2.0 INCH - - - - - F-LOOP UTILITY SWITCH H2-LOOP UTILITY SWITCH INSTALL CONDUIT AT A DEPTH OF 4'. PROVIDE CONDUIT AND PULL ROPE PER

CLPUD REQUIREMENTS. INSTALL CONDUIT WITH 3' SWEEPS. -

P110 2 2.0 INCH - - - - - JB-COM-1 JB-COM-E CONDUIT IS FOR FUTURE FIBER OPTIC COMMUNICATION -

P111 2 2.0 INCH - - - - - JB-COM-E JB-COM-G CONDUIT IS FOR FUTURE FIBER OPTIC COMMUNICATION. ROUTE VIA

IN-GROUND BOXES AS SHOWN ON THE PLANS. -

P112 2 2.0 INCH - - - - - JB-COM-E E22 FIBER OPTIC BOX CONDUIT IS FOR FUTURE FIBER OPTIC COMMUNICATION. TERMINATE CONDUIT

AT EXISTING FIBER OPTIC JUNCTION BOX. -

P113 1 2.0 INCH - - - - - JB-COM-1 JB-COM-3 CONDUIT IS FOR FUTURE FIBER OPTIC COMMUNICATION. ROUTE FROM

REGISTRATION BUILDING TO PARK RANGER'S OFFICE. -

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

CONDUIT SCHEDULES

E1.1

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

POWER CONDUIT / CONDUCTOR SCHEDULE

CONDUIT ID

NO.

CONDUIT CONDUCTORS PER CONDUIT

FROM TO DESCRIPTION NOTES

QUANTITY SIZE UNGROUNDED GROUNDED GROUNDING CABLE SPARE

GENERAL SHEET NOTES

1. CONTRACTOR SHALL REFERENCE SECTION

16131 CONDUITS AND FITTINGS FOR CONDUIT

INSTALLATION REQUIREMENTS.

P200 1 3.0 INCH - - - - - UTILITY POLE #100981 A-LOOP UTILITY TRANSFORMER - -

P201 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - A-LOOP UTILITY TRANSFORMER A-LOOP UTILITY METER - -

P202 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - A-LOOP UTILITY METER A-LOOP MAIN DISCONNECT - -

P203 1 0.75 INCH - - 1 - #2 - - A-LOOP MAIN DISCONNECT GROUNDING ELECTRODE SYSTEM CONDUIT SHALL BE PVC. -

P204 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - A-LOOP MAIN DISCONNECT A-LOOP MANUAL TRANSFER SWITCH - -

P205 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - A-LOOP MANUAL TRANSFER SWITCH A-LOOP KIOSK - -

P206 2 2.0 INCH 2 - #3/0 - 1 - #3 - - A-LOOP GENERATOR RECEPTACLE A-LOOP MTS - -

P210 1 2.0 INCH 2 - #4/0 1 - #4/0 1 - #3 - - A-LOOP KIOSK YURT SITES A2, A4, A6, A8, A10, A12, A14, A16, A18, A19 CIRCUITS #2,4 -

P211 1 1.25 INCH 2 - #4 1 - #4 1 - #4 - - A-LOOP KIOSK HIKER BIKER CAMP SITE CIRCUITS #6,8 -

P212 1 2.0 INCH 2 - #4/0 1 - #4/0 1 - #4 - - A-LOOP KIOSK A-LOOP RESTROOM CIRCUITS #10,12 -

P213 1 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - A-LOOP KIOSK YURT SITES A21, A23, A24, A25, A26, A27 CIRCUITS #1,3 -

P214 1 0.75 INCH 1 - #12 1 - #12 1 - #12 - - A-LOOP KIOSK KIOSK LIGHT & RECEPTACLE CIRCUIT #5 -

P215 2 1.0 INCH - - - - - A-LOOP KIOSK JB-A1 - -

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

CONDUIT SCHEDULES

E1.2

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

POWER CONDUIT / CONDUCTOR SCHEDULE

CONDUIT ID

NO.

CONDUIT CONDUCTORS PER CONDUIT

FROM TO DESCRIPTION NOTES

QUANTITY SIZE UNGROUNDED GROUNDED GROUNDING CABLE SPARE

GENERAL SHEET NOTES

1. CONTRACTOR SHALL REFERENCE SECTION

16131 CONDUITS AND FITTINGS FOR CONDUIT

INSTALLATION REQUIREMENTS.

P300 - - - - - - - UTILITY POLE #100984 B-LOOP KIOSK UTILITY METER

ROUTE CONDUIT FROM THE METER TO THE POLE AND INSTALL AT A DEPTH OF

4'. STUB UP CONDUIT AT THE POLE AND CLPUD WILL ROUTE THE CONDUIT UP

THE POLE.

P301 2 2.5 INCH 3 - #3/0 1 - #3/0 - - - B-LOOP UTILITY METER B-LOOP MAIN DISCONNECT - -

P302 1 0.75 INCH - - 1 - #2 - - B-LOOP MAIN DISCONNECT GROUNDING ELECTRODE SYSTEM - -

P303 2 2.5 INCH 3 - #3/0 1 - #3/0 1 - #3 - - B-LOOP MAIN DISCONNECT B-LOOP MANUAL TRANSFER SWITCH - -

P304 2 2.5 INCH 3 - #3/0 1 - #3/0 1 - #3 - - B-LOOP MANUAL TRANSFER SWITCH B-LOOP KIOSK - -

P305 2 2.0 INCH 2 - #3/0 - 1 - #3 - - B-LOOP GENERATOR RECEPTACLE B-LOOP MTS - -

P310 1 1.25 INCH 3 - #4 - 1 - #8 - - B-LOOP KIOSK B-LOOP LIFT STATION - -

P311 1 1.25 INCH 2 - #2 - 1 - #8 - - B-LOOP KIOSK GARBAGE COMPACTOR - -

P320 1 2.5 INCH 3 - #3/0 1 - #3/0 - - - PARK ENTRANCE UTILITY SWITCH C-LOOP LIFT STATION UTILITY METER - -

P321 1 2.5 INCH 3 - #3/0 1 - #3/0 - - - C-LOOP MAIN DISCONNECT GROUNDING ELECTRODE SYSTEM - -

P322 1 1.0 INCH 3 - #8 - 1 - #10 - - C-LOOP TRANSFER SWITCH GROUNDING ELECTRODE SYSTEM - -

P323 1 0.75 INCH 1 - #12 1 - #12 1 - #12 - - C-LOOP LIFT STATION PANEL C-LOOP PUMP CONTROL PANEL (PCP) - -

P324 1 0.75 INCH 1 - #12 1 - #12 1 - #12 - - C-LOOP LIFT STATION PANEL KIOSK LIGHT & RECEPTACLE - -

P325 1 6.0 INCH - - - 1 - MSC - C-LOOP PCP C-LOOP PUMP #1

ROUTE PUMP CABLE WITH MALE CORD END. INSTALL MANUFACTURER

SUPPLIED CABLE IN 6" PVC CONDUIT ROUTED FROM WETWELL TO A POINT

DIRECTLY BELOW THE PUMP CONTROL PANEL. CONDUIT SHALL STUB UP 6"

ABOVE FINISHED GRADE WITH AIR GAP BETWEEN CONDUIT & CONTROL PANEL.

P326 1 6.0 INCH - - - 1 - MSC - C-LOOP PCP C-LOOP PUMP #2

ROUTE PUMP CABLE WITH MALE CORD END. INSTALL MANUFACTURER

SUPPLIED CABLE IN 6" PVC CONDUIT ROUTED FROM WETWELL TO A POINT

DIRECTLY BELOW THE PUMP CONTROL PANEL. CONDUIT SHALL STUB UP 6"

ABOVE FINISHED GRADE WITH AIR GAP BETWEEN CONDUIT & CONTROL PANEL.

P327 1 2.0 INCH - - - 2 - MSC - C-LOOP PCP WET WELL

WET LEVEL ELEMENT, AND LEVEL HIGH ALARM. INSTALL MANUFACTURER

SUPPLIED CABLE IN 2.0 INCH CONDUIT ROUTED FROM WETWELL TO POINT

DIRECTLY BELOW CONTROL PANEL. CONDUIT SHALL STUB UP 6" ABOVE

FINISHED GRADE. LEAVE AIR GAP BETWEEN CONDUIT AND CONTROL PANEL.

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

CONDUIT SCHEDULES

E1.3

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

POWER CONDUIT / CONDUCTOR SCHEDULE

CONDUIT ID

NO.

CONDUIT CONDUCTORS PER CONDUIT

FROM TO DESCRIPTION NOTES

QUANTITY SIZE UNGROUNDED GROUNDED GROUNDING CABLE SPARE

GENERAL SHEET NOTES

1. CONTRACTOR SHALL REFERENCE SECTION

16131 CONDUITS AND FITTINGS FOR CONDUIT

INSTALLATION REQUIREMENTS.

P400 1 2.0 INCH - - - - - C-LOOP UTILITY SWITCH C-LOOP TRANSFORMER - -

P401 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - C-LOOP TRANSFORMER C-LOOP UTILITY METER - -

P402 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - C-LOOP UTILITY METER C-LOOP MAIN DISCONNECT - -

P403 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - C-LOOP MAIN DISCONNECT C-LOOP MANUAL TRANSFER SWITCH - -

P404 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - C-LOOP MANUAL TRANSFER SWITCH C-LOOP KIOSK - -

P405 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - C-LOOP KIOSK C-LOOP SUB-PANEL - -

P406 1 0.75 INCH - - 1 - #2 - - C-LOOP MAIN DISCONNECT GROUNDING ELECTRODE SYSTEM CONDUIT SHALL BE PVC. -

P407 2 2.0 INCH 2 - #3/0 - 1 - #3 - - C-LOOP GENERATOR RECEPTACLE C-LOOP MTS - -

P410 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - C-LOOP KIOSK RV SITE, C-8 - -

P411 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - C-LOOP KIOSK RV SITE, C-9 - -

P412 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - C-LOOP KIOSK RV SITE, C-10 - -

P413 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - C-LOOP KIOSK RV SITE, C-11 - -

P414 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - C-LOOP KIOSK RV SITE, C-12 - -

P415 1 2.0 INCH 2 - #3/0 1 - #3/0 1 - #6 - - C-LOOP KIOSK C-LOOP RESTROOM - -

PXXX - - - - - - - - - - -

P420 1 1.25 INCH 2 - #4 1 - #4 1 - #8 - - C-LOOP SUB-PANEL RV SITE, C-1 - -

P421 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - C-LOOP SUB-PANEL RV SITE, C-2 - -

P422 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - C-LOOP SUB-PANEL RV SITE, C-3 - -

P423 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - C-LOOP SUB-PANEL RV SITE, C-4 - -

P424 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - C-LOOP SUB-PANEL RV SITE, C-5 - -

P425 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - C-LOOP SUB-PANEL RV SITE, C-6 - -

P426 1 1.25 INCH 2 - #4 1 - #4 1 - #8 - - C-LOOP SUB-PANEL RV SITE, C-7 - -

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

CONDUIT SCHEDULES

E1.4

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

POWER CONDUIT / CONDUCTOR SCHEDULE

CONDUIT ID

NO.

CONDUIT CONDUCTORS PER CONDUIT

FROM TO DESCRIPTION NOTES

QUANTITY SIZE UNGROUNDED GROUNDED GROUNDING CABLE SPARE

GENERAL SHEET NOTES

1. CONTRACTOR SHALL REFERENCE SECTION

16131 CONDUITS AND FITTINGS FOR CONDUIT

INSTALLATION REQUIREMENTS.

P500 1 2.0 INCH - - - - - D-LOOP UTILITY SWITCH D-LOOP TRANSFORMER - -

P501 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - D-LOOP TRANSFORMER D-LOOP UTILITY METER - -

P502 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - D-LOOP UTILITY METER D-LOOP MAIN DISCONNECT - -

P503 1 0.75 INCH - - 1 - #2 - - D-LOOP MAIN DISCONNECT GROUNDING ELECTRODE SYSTEM CONDUIT SHALL BE PVC. -

P504 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - D-LOOP MAIN DISCONNECT D-LOOP MANUAL TRANSFER SWITCH - -

P505 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - D-LOOP MANUAL TRANSFER SWITCH D-LOOP KIOSK - -

P506 2 2.0 INCH 2 - #3/0 - 1 - #3 - - D-LOOP GENERATOR RECEPTACLE D-LOOP MTS - -

P510 1 1.25 INCH 2 - #4 1 - #4 1 - #6 - - D-LOOP KIOSK RV SITE, D-2 - -

P511 1 1.0 INCH 2 - #6 1 - #6 1 - #6 - - D-LOOP KIOSK RV SITE, D-4 - -

P512 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - D-LOOP KIOSK RV SITE, D-6 - -

P513 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - D-LOOP KIOSK RV SITE, D-8 - -

P514 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - D-LOOP KIOSK RV SITE, D-10 - -

P515 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - D-LOOP KIOSK RV SITE, D-12 - -

P516 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - D-LOOP KIOSK RV SITE, D-13 - -

P517 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - D-LOOP KIOSK RV SITE, D-15 - -

P518 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - D-LOOP KIOSK RV SITE, D-16 - -

P519 1 2.5 INCH 2 - #4/0 1 - #4/0 1 - #4 - - D-LOOP KIOSK D-LOOP RESTROOM ROUTE VIA JUNCTION BOXES AS SHOWN ON PLANS. -

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

CONDUIT SCHEDULES

E1.5

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

POWER CONDUIT / CONDUCTOR SCHEDULE

CONDUIT ID

NO.

CONDUIT CONDUCTORS PER CONDUIT

FROM TO DESCRIPTION NOTES

QUANTITY SIZE UNGROUNDED GROUNDED GROUNDING CABLE SPARE

GENERAL SHEET NOTES

1. CONTRACTOR SHALL REFERENCE SECTION

16131 CONDUITS AND FITTINGS FOR CONDUIT

INSTALLATION REQUIREMENTS.

P600 1 2.0 INCH - - - - - E-LOOP UTILITY SWITCH E-LOOP TRANSFORMER - -

P601 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - E-LOOP TRANSFORMER E-LOOP UTILITY METER - -

P602 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - E-LOOP UTILITY METER E-LOOP MAIN DISCONNECT - -

P603 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - E-LOOP MAIN DISCONNECT E-LOOP MANUAL TRANSFER SWITCH - -

P604 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - E-LOOP MANUAL TRANSFER SWITCH E-LOOP KIOSK - -

P605 1 2.0 INCH 2 - #3/0 1 - #3/0 1 - #6 - - E-LOOP KIOSK E-LOOP SUB-PANEL - -

P606 1 0.75 INCH - - 1 - #2 - - E-LOOP MAIN DISCONNECT GROUNDING ELECTRODE SYSTEM CONDUIT SHALL BE PVC. -

P607 2 2.0 INCH 2 - #3/0 - 1 - #3 - - E-LOOP GENERATOR RECEPTACLE E-LOOP MTS - -

P610 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - E-LOOP KIOSK RV SITE, E-6 - -

P611 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - E-LOOP KIOSK RV SITE, E-7 - -

P612 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - E-LOOP KIOSK RV SITE, E-8 - -

P613 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - E-LOOP KIOSK RV SITE, E-9 - -

P614 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - E-LOOP KIOSK RV SITE, F-1 - -

P615 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - E-LOOP KIOSK RV SITE, F-2 - -

P616 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - E-LOOP KIOSK RV SITE, F-3 - -

P617 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - E-LOOP KIOSK RV SITE, F-4 - -

P618 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - E-LOOP KIOSK E-LOOP AMPHITHEATER PANEL - -

P619 1 2.0 INCH 2 - #3/0 1 - #3/0 1 - #6 - - E-LOOP KIOSK E-LOOP RESTROOM - -

P630 1 1.25 INCH 2 - #3 1 - #3 1 - #6 - - E-LOOP SUB-PANEL RV SITE, E-1 - -

P631 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - E-LOOP SUB-PANEL RV SITE, E-2 - -

P632 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - E-LOOP SUB-PANEL RV SITE, E-3 - -

P633 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - E-LOOP SUB-PANEL RV SITE, E-4 - -

P634 1 1.25 INCH 2 - #4 1 - #4 1 - #6 - - E-LOOP SUB-PANEL RV SITE, E-5 - -

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

CONDUIT SCHEDULES

E1.6

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

POWER CONDUIT / CONDUCTOR SCHEDULE

CONDUIT ID

NO.

CONDUIT CONDUCTORS PER CONDUIT

FROM TO DESCRIPTION NOTES

QUANTITY SIZE UNGROUNDED GROUNDED GROUNDING CABLE SPARE

GENERAL SHEET NOTES

1. CONTRACTOR SHALL REFERENCE SECTION

16131 CONDUITS AND FITTINGS FOR CONDUIT

INSTALLATION REQUIREMENTS.

P700 1 2.0 INCH - - - - - F-LOOP UTILITY SWITCH F-LOOP TRANSFORMER - -

P701 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - F-LOOP TRANSFORMER F-LOOP UTILITY METER - -

P702 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - F-LOOP UTILITY METER F-LOOP MAIN DISCONNECT - -

P703 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - F-LOOP MAIN DISCONNECT F-LOOP MANUAL TRANSFER SWITCH - -

P704 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - F-LOOP MANUAL TRANSFER SWITCH F-LOOP KIOSK - -

P705 1 2.5 INCH 2 - #4/0 1 - #4/0 1 - #2 - - F-LOOP KIOSK F-LOOP SUB-PANEL - -

P706 1 0.75 INCH - - 1 - #2 - - F-LOOP MAIN DISCONNECT GROUNDING ELECTRODE SYSTEM CONDUIT SHALL BE PVC. -

P707 2 2.0 INCH 2 - #3/0 - 1 - #3 - - F-LOOP GENERATOR RECEPTACLE F-LOOP MTS - -

P710 1 1.25 INCH 2 - #4 1 - #4 1 - #6 - - F-LOOP KIOSK RV SITE, F-5 - -

P711 1 1.25 INCH 2 - #4 1 - #4 1 - #6 - - F-LOOP KIOSK RV SITE, F-6 - -

P712 1 1.25 INCH 2 - #4 1 - #4 1 - #6 - - F-LOOP KIOSK RV SITE, F-7 - -

P713 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - F-LOOP KIOSK RV SITE, F-8 - -

P714 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - F-LOOP KIOSK RV SITE, F-10 - -

P715 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - F-LOOP KIOSK RV SITE, F-12 - -

P716 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - F-LOOP KIOSK RV SITE, F-13 - -

P717 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - F-LOOP KIOSK RV SITE, F-15 - -

P718 1 2.5 INCH 2 - #4/0 1 - #4/0 1 - #2 - - F-LOOP KIOSK F-LOOP RESTROOM - -

P730 1 1.25 INCH 2 - #4 1 - #4 1 - #4 - - F-LOOP SUB-PANEL YURT SITE, F-26 - -

P731 1 1.25 INCH 2 - #4 1 - #4 1 - #4 - - F-LOOP SUB-PANEL YURT SITE, F-27 - -

P732 1 1.0 INCH 2 - #6 1 - #6 1 - #6 - - F-LOOP SUB-PANEL YURT SITE, F-29 - -

P733 1 1.0 INCH 2 - #6 1 - #6 1 - #6 - - F-LOOP SUB-PANEL YURT SITE, F-32 - -

P734 1 1.0 INCH 2 - #6 1 - #6 1 - #6 - - F-LOOP SUB-PANEL YURT SITE, F-35 - -

P735 1 1.0 INCH 2 - #6 1 - #6 1 - #4 - - F-LOOP SUB-PANEL YURT SITE, F-36 - -

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

CONDUIT SCHEDULES

E1.7

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

POWER CONDUIT / CONDUCTOR SCHEDULE

CONDUIT ID

NO.

CONDUIT CONDUCTORS PER CONDUIT

FROM TO DESCRIPTION NOTES

QUANTITY SIZE UNGROUNDED GROUNDED GROUNDING CABLE SPARE

GENERAL SHEET NOTES

1. CONTRACTOR SHALL REFERENCE SECTION

16131 CONDUITS AND FITTINGS FOR CONDUIT

INSTALLATION REQUIREMENTS.

P800 1 2.0 INCH - - - - - F-LOOP UTILITY SWITCH G1-LOOP TRANSFORMER - -

P801 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - G1-LOOP TRANSFORMER G1-LOOP UTILITY METER - -

P802 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - G1-LOOP UTILITY METER G1-LOOP MAIN DISCONNECT - -

P803 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - G1-LOOP MAIN DISCONNECT G1-LOOP MANUAL TRANSFER SWITCH - -

P804 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - G1-LOOP MANUAL TRANSFER SWITCH G1-LOOP KIOSK - -

P805 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #6 - - G1-LOOP KIOSK G1-LOOP SUB-PANEL - -

P806 1 0.75 INCH - - 1 - #2 - - G1-LOOP MAIN DISCONNECT GROUNDING ELECTRODE SYSTEM CONDUIT SHALL BE PVC. -

P807 2 2.0 INCH 2 - #3/0 - 1 - #3 - - G1-LOOP GENERATOR RECEPTACLE G1-LOOP MTS - -

P810 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G1-LOOP KIOSK RV SITE, F-9 - -

P811 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G1-LOOP KIOSK RV SITE, F-11 - -

P812 1 1.25 INCH 2 - #4 1 - #4 1 - #6 - - G1-LOOP KIOSK RV SITE, G-30 - -

P813 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G1-LOOP KIOSK RV SITE, G-32 - -

P814 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G1-LOOP KIOSK RV SITE, G-33 - -

P815 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G1-LOOP KIOSK RV SITE, G-34 - -

P816 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G1-LOOP KIOSK RV SITE, G-35 - -

P817 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G1-LOOP KIOSK RV SITE, G-36 - -

P818 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G1-LOOP KIOSK RV SITE, G-37 - -

P819 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G1-LOOP KIOSK RV SITE, G-38 - -

P830 1 1.25 INCH 2 - #4 1 - #4 1 - #6 - - G1-LOOP SUB-PANEL RV SITE, G-24 - -

P831 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G1-LOOP SUB-PANEL RV SITE, G-25 - -

P832 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G1-LOOP SUB-PANEL RV SITE, G-27 - -

P833 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G1-LOOP SUB-PANEL RV SITE, G-28 - -

P834 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G1-LOOP SUB-PANEL RV SITE, G-29 - -

P835 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G1-LOOP SUB-PANEL RV SITE, G-31 - -

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

CONDUIT SCHEDULES

E1.8

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

POWER CONDUIT / CONDUCTOR SCHEDULE

CONDUIT ID

NO.

CONDUIT CONDUCTORS PER CONDUIT

FROM TO DESCRIPTION NOTES

QUANTITY SIZE UNGROUNDED GROUNDED GROUNDING CABLE SPARE

GENERAL SHEET NOTES

1. CONTRACTOR SHALL REFERENCE SECTION

16131 CONDUITS AND FITTINGS FOR CONDUIT

INSTALLATION REQUIREMENTS.

P900 1 2.0 INCH - - - - - F-LOOP UTILITY SWITCH G2-LOOP TRANSFORMER INSTALL CONDUIT AT A DEPTH OF 3'. PROVIDE CONDUIT AND PULL ROPE PER

CLPUD REQUIREMENTS. INSTALL CONDUIT WITH 3' SWEEPS. -

P901 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - G2-LOOP TRANSFORMER G2-LOOP UTILITY METER - -

P902 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - G2-LOOP UTILITY METER G2-LOOP MAIN DISCONNECT - -

P903 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - G2-LOOP MAIN DISCONNECT G2-LOOP MANUAL TRANSFER SWITCH - -

P904 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - G2-LOOP MANUAL TRANSFER SWITCH G2-LOOP KIOSK - -

P905 2 2.5 INCH 2 - #4/0 1 - #4/0 1 - #1 - - G2-LOOP KIOSK G2-LOOP SUB-PANEL - -

P906 1 0.75 INCH - - 1 - #2 - - G2-LOOP MAIN DISCONNECT GROUNDING ELECTRODE SYSTEM CONDUIT SHALL BE PVC. -

P907 2 2.0 INCH 2 - #3/0 - 1 - #3 - - G2-LOOP GENERATOR RECEPTACLE G2-LOOP MTS - -

P910 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G2-LOOP KIOSK RV SITE, H-1 - -

P911 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G2-LOOP KIOSK RV SITE, H-2 - -

P912 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G2-LOOP KIOSK RV SITE, H-3 - -

P913 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G2-LOOP KIOSK RV SITE, H-4 - -

P914 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G2-LOOP KIOSK RV SITE, H-5 - -

P915 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G2-LOOP KIOSK RV SITE, H-6 - -

P916 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G2-LOOP KIOSK RV SITE, H-7 - -

PXXX - - - - - - - - - - -

P930 1 1.25 INCH 2 - #4 1 - #4 1 - #6 - - G2-LOOP SUB-PANEL RV SITE, G-15 - -

P931 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G2-LOOP SUB-PANEL RV SITE, G-16 - -

P932 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G2-LOOP SUB-PANEL RV SITE, G-17 - -

P933 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G2-LOOP SUB-PANEL RV SITE, G-18 - -

P934 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G2-LOOP SUB-PANEL RV SITE, G-19 - -

P935 1 1.25 INCH 2 - #4 1 - #4 1 - #6 - - G2-LOOP SUB-PANEL RV SITE, G-20 - -

P936 1 1.25 INCH 2 - #4 1 - #4 1 - #6 - - G2-LOOP SUB-PANEL RV SITE, G-21 - -

P937 1 1.25 INCH 2 - #3 1 - #3 1 - #6 - - G2-LOOP SUB-PANEL RV SITE, G-22 - -

P938 1 1.25 INCH 2 - #4 1 - #4 1 - #6 - - G2-LOOP SUB-PANEL RV SITE, G-23 - -

P939 1 1.25 INCH 2 - #3 1 - #3 1 - #6 - - G2-LOOP SUB-PANEL RV SITE, G-26 - -

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

CONDUIT SCHEDULES

E1.9

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

POWER CONDUIT / CONDUCTOR SCHEDULE

CONDUIT ID

NO.

CONDUIT CONDUCTORS PER CONDUIT

FROM TO DESCRIPTION NOTES

QUANTITY SIZE UNGROUNDED GROUNDED GROUNDING CABLE SPARE

GENERAL SHEET NOTES

1. CONTRACTOR SHALL REFERENCE SECTION

16131 CONDUITS AND FITTINGS FOR CONDUIT

INSTALLATION REQUIREMENTS.

P1000 1 2.0 INCH - - - - - F-LOOP UTILITY SWITCH G3-LOOP TRANSFORMER INSTALL CONDUIT AT A DEPTH OF 3'. PROVIDE CONDUIT AND PULL ROPE PER

CLPUD REQUIREMENTS. INSTALL CONDUIT WITH 3' SWEEPS. -

P1001 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - G3-LOOP TRANSFORMER G3-LOOP UTILITY METER - -

P1002 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - G3-LOOP UTILITY METER G3-LOOP MAIN DISCONNECT - -

P1003 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - G3-LOOP MAIN DISCONNECT G3-LOOP MANUAL TRANSFER SWITCH - -

P1004 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - G3-LOOP MANUAL TRANSFER SWITCH G3-LOOP KIOSK - -

P1005 2 2.5 INCH 2 - #4/0 1 - #4/0 1 - #1 - - G3-LOOP KIOSK G3-LOOP SUB-PANEL - -

P1006 1 0.75 INCH - - 1 - #2 - - G3-LOOP MAIN DISCONNECT GROUNDING ELECTRODE SYSTEM CONDUIT SHALL BE PVC. -

P1007 2 2.0 INCH 2 - #3/0 - 1 - #3 - - G3-LOOP GENERATOR RECEPTACLE G3-LOOP MTS - -

P1010 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G3-LOOP KIOSK RV SITE, G-7 - -

P1011 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G3-LOOP KIOSK RV SITE, G-8 - -

P1012 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G3-LOOP KIOSK RV SITE, G-9 - -

P1013 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G3-LOOP KIOSK RV SITE, G-10 - -

P1014 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G3-LOOP KIOSK RV SITE, G-11 - -

P1015 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G3-LOOP KIOSK RV SITE, G-12 - -

P1016 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G3-LOOP KIOSK RV SITE, G-13 - -

P1017 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G3-LOOP KIOSK RV SITE, G-14 - -

P1030 1 1.25 INCH 2 - #4 1 - #4 1 - #8 - - G3-LOOP SUB-PANEL RV SITE, H-9 - -

P1031 1 1.25 INCH 2 - #4 1 - #4 1 - #8 - - G3-LOOP SUB-PANEL RV SITE, G-1 - -

P1032 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G3-LOOP SUB-PANEL RV SITE, G-2 - -

P1033 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G3-LOOP SUB-PANEL RV SITE, G-3 - -

P1034 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G3-LOOP SUB-PANEL RV SITE, G-4 - -

P1035 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - G3-LOOP SUB-PANEL RV SITE, G-5 - -

P1036 1 1.0 INCH 2 - #6 1 - #6 1 - #6 - - G3-LOOP SUB-PANEL RV SITE, G-6 - -

P1037 1 1.0 INCH 2 - #6 1 - #6 1 - #6 - - G3-LOOP SUB-PANEL RV SITE, H-10 - -

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

AutoCAD SHX Text

SHEET:

AutoCAD SHX Text

OPRIS#:

AutoCAD SHX Text

PARKS

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

STATE

AutoCAD SHX Text

CONTRACT #:

AutoCAD SHX Text

BEVERLY BEACH

AutoCAD SHX Text

ELECTRICAL PROJECT

AutoCAD SHX Text 04/17/2023

AutoCAD SHX Text

EJC

AutoCAD SHX Text

MB

AutoCAD SHX Text

MB

AutoCAD SHX Text

BP

AutoCAD SHX Text

CONDUIT SCHEDULES

E1.10

503-584-1576 www.landisconsulting.com

Landis Consulting

ENGINEERING SERVICES

H

IS

T O R Y

N at u re

D is co ve ry

PDERETSI

GER LA

NOI

SSEFOR

OREGON

86683

NIG

N

E R

EE

8 , 2

M A Y

PERRY

B

EN

JAMI N

E.

EXPIRES: 12-31-2024

Digitally Signed

POWER CONDUIT / CONDUCTOR SCHEDULE

CONDUIT ID

NO.

CONDUIT CONDUCTORS PER CONDUIT

FROM TO DESCRIPTION NOTES

QUANTITY SIZE UNGROUNDED GROUNDED GROUNDING CABLE SPARE

GENERAL SHEET NOTES

1. CONTRACTOR SHALL REFERENCE SECTION

16131 CONDUITS AND FITTINGS FOR CONDUIT

INSTALLATION REQUIREMENTS.

P1100 1 2.0 INCH - - - - - H1-LOOP UTILITY SWITCH H-LOOP TRANSFORMER - -

P1101 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - H-LOOP TRANSFORMER H1-LOOP UTILITY METER - -

P1102 2 2.0 INCH 2 - #3/0 1 - #3/0 - - - H1-LOOP UTILITY METER H1-LOOP MAIN DISCONNECT - -

P1103 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - H1-LOOP MAIN DISCONNECT H1-LOOP MANUAL TRANSFER SWITCH - -

P1104 2 2.0 INCH 2 - #3/0 1 - #3/0 1 - #3 - - H1-LOOP MANUAL TRANSFER SWITCH H1-LOOP KIOSK - -

P1105 1 2.0 INCH 2 - #3/0 1 - #3/0 1 - #4 - - H1-LOOP KIOSK H1-LOOP SUB-PANEL - -

P1106 1 0.75 INCH - - 1 - #2 - - H1-LOOP MAIN DISCONNECT GROUNDING ELECTRODE SYSTEM CONDUIT SHALL BE PVC. -

P1107 2 2.0 INCH 2 - #3/0 - 1 - #3 - - H1-LOOP GENERATOR RECEPTACLE H1-LOOP MTS - -

P1110 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - H1-LOOP KIOSK RV SITE, H-12 - -

P1111 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - H1-LOOP KIOSK RV SITE, H-13 - -

P1112 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - H1-LOOP KIOSK RV SITE, H-14 - -

P1113 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - H1-LOOP KIOSK RV SITE, H-15 - -

P1114 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - H1-LOOP KIOSK RV SITE, H-16 - -

P1115 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - H1-LOOP KIOSK RV SITE, H-17 - -

P1116 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - H1-LOOP KIOSK RV SITE, H-18 - -

P1130 1 1.25 INCH 2 - #3 1 - #3 1 - #6 - - H1-LOOP SUB-PANEL RV SITE, F-14 - -

P1131 1 1.25 INCH 2 - #4 1 - #4 1 - #6 - - H1-LOOP SUB-PANEL RV SITE, F-16 - -

P1132 1 1.25 INCH 2 - #4 1 - #4 1 - #6 - - H1-LOOP SUB-PANEL RV SITE, F-17 - -

P1133 1 1.25 INCH 2 - #4 1 - #4 1 - #6 - - H1-LOOP SUB-PANEL RV SITE, F-18 - -

P1134 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - H1-LOOP SUB-PANEL RV SITE, F-19 - -

P1135 1 1.0 INCH 2 - #6 1 - #6 1 - #8 - - H1-LOOP SUB-PANEL RV SITE, F-20 - -

AutoCAD SHX Text

DESIGNED BY

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OREGON PARKS AND RECREATION DEPARTMENT

Auto…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .