ATT_B_P0.00.pdf
PDF 1 MB Posted
- Attached to
- OCYCF Med/Dental Remodel
- Solicitation number
- S-DASOBO-00001190
- Issued by
- Lake County, Albany City, Oregon
About this file
This document contains the general notes, abbreviations, and sheet index for a plumbing scope of work as part of the OCYCF Med/Dental Remodel Project for the benefit of the Oregon Youth Authority. The project includes work such as compliance with local codes, plumbing system requirements, coordination with other trades, seismic restraint, submittals, and project closeout. The plumbing work entails demolition of the existing plumbing system, installation of new underground plumbing, waste and vent system, domestic water system, and associated plumbing details. The project is located in Albany, Oregon, which is within Linn County.
The document provides plumbing equipment and fixture schedules, water service calculations, and a domestic hot water recirculation schematic. Pricing terms, set asides, incumbents, funding requirements, and other salient commercial information are not included in this technical document.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE LATEST EDITION OF
THE FOLLOWING CODES AS ADOPTED BY THE AUTHORITY HAVING JURISDICTION.
OREGON STRUCTURAL SPECIALTY CODE (OSSC)
OREGON MECHANICAL SPECIALTY CODE
OREGON PLUMBING SPECIALTY CODE
OREGON FIRE CODE
OREGON STATE ENERGY CODE WITH LOCAL AMENDMENTS
2. THE SCOPE OF THE PLUMBING WORK CONSISTS OF WORK SHOWN ON THE PLANS AND AS DESCRIBED IN THE SPECIFICATIONS. IN CASE OF CONFLICT, THE SPECIFICATIONS SHALL GOVERN. PROVIDE A COMPLETE &
FUNCTIONAL SYSTEM.
3. PERFORM ALL WORK IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES. OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND PAY FOR ALL FEES REQUIRED BY AUTHORITIES HAVING JURISDICTION. PAY ALL ROYALTIES OR FEES REQUIRED IN CONNECTION WITH THE USE OF PATENTED DEVICES AND SYSTEMS.
4. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL CONSTRUCTION INCLUDING CONCRETE EQUIPMENT PADS, FLASHING DETAILS, ETC. REFER TO ARCHITECTURAL DRAWINGS FOR ROOM ELEVATIONS, LOCATE PLUMBING DEVICES SO THAT THEY DO NOT CONFLICT WITH GENERAL CONSTRUCTION (WAINSCOT, DOOR HARDWARE, ETC.) NOR WITH ELECTRICAL SYSTEM (LIGHT SWITCHES, SPEAKERS, OUTLETS, ETC.).
5. COORDINATE WITH OTHER TRADES:
A. REFER TO ELECTRICAL DRAWINGS AND CONFIRM ELECTRICAL CHARACTERISTICS SHOWN FOR PLUMBING
EQUIPMENT (VOLTAGE, PHASE, HZ, ETC). MATCHES THAT OF THE PLUMBING EQUIPMENT PROVIDED.
B. PROVIDE ADEQUATE CLEARANCE OF PLUMBING WORK FROM ELECTRICAL EQUIPMENT. MAINTAIN
MINIMUM ACCESS OF 6-INCHES ABOVE CABLE TRAYS AND 18-INCHES TO THE SIDE OF CABLE TRAYS.
CLEARANCE ABOVE CABLE TRAY SHOULD BE 1/2 THE WIDTH AND NOT LESS THAN 6-INCHES WHEN RUNNING PARALLEL WITH CABLE TRAY. AND NOT LESS THAN 6-INCHES WHEN RUNNING PERPENDICULAR
TO THE CABLE TRAY.
6. ARRANGE EQUIPMENT SO THAT ACCESS CLEARANCES INDICATED BY DRAWINGS, REQUIRED BY CODES, OR
RECOMMENDED BY MANUFACTURER ARE PROVIDED.
7. INSTALL MATERIALS AND SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND ACCEPTED SUBMITTALS. INSTALL MATERIAL IN PROPER RELATION TO ADJACENT CONSTRUCTION AND WITH UNIFORM
APPEARANCE FOR EXPOSED WORK.
8. THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, AND PIPING WILL BE INSTALLED AND REPORT ANY
CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE PLUMBING WORK.
9. THE COMMISSIONING SPECIFICATION, INCLUDING ALL FUNCTIONAL TEST PROCEDURES, SHALL BE PROVIDED
AND ENFORCED BY THE CONTRACTOR.
10. PROVIDE SEISMIC RESTRAINT IN ACCORDANCE WITH IBC AND ASCE STANDARD 7. SUBMIT CALCULATIONS BY LICENSED STRUCTURAL ENGINEER. PRODUCTS MAY CONFORM TO SMACNA SEISMIC RESTRAINT GUIDELINES.
11. PROVIDE A SINGLE SUBMITTAL OF ALL PLUMBING EQUIPMENT AS SPECIFIED. AS A MINIMUM, SUBMIT PRODUCT DATA FOR ALL EQUIPMENT AND FIXTURES LISTED IN ACCOMPANYING SCHEDULES FOR APPROVAL.
12. USE EXPERIENCED INSTALLERS. DELIVER, HANDLE, AND STORE MATERIALS IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
13. ARRANGEMENT OF SYSTEMS INDICATED ON THE DRAWINGS IS DIAGRAMMATIC, AND INDICATES THE MINIMUM REQUIREMENTS FOR PLUMBING WORK. SITE CONDITIONS SHALL DETERMINE THE ACTUAL ARRANGEMENT OF THE WORK. TAKE FIELD MEASUREMENTS BEFORE PREPARING SHOP DRAWINGS, OBTAIN APPROVAL OF SHOP DRAWINGS BEFORE BEGINNING FABRICATION. BE RESPONSIBLE FOR ACCURACY OF DIMENSIONS AND
LAYOUT. OVERHEAD PIPING SHALL BE ARRANGED TO OBTAIN MAXIMUM HEAD ROOM.
14. CLEAN AND PROTECT WORK FROM DAMAGE. RESTORE DAMAGED FINISHES. COVER ENDS OF PIPING NOT
ACTIVELY BEING WORKED ON.
15. MODIFY AND EXTEND EXISTING SERVICE TO ACCOMMODATE NEW WORK. RELOCATE EXISTING COMPONENTS
AS REQUIRED FOR NEW SYSTEM. COORDINATE WITH BUILDING MANAGEMENT.
16. PROVIDE PRODUCTS OF ACCEPTABLE MANUFACTURERS, WHICH HAVE BEEN IN SATISFACTORY USE IN SIMILAR
SERVICE FOR THREE YEARS. DELIVER, HANDLE, AND STORE MATERIALS IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
17. DO NOT CUT STRUCTURAL ELEMENTS WITHOUT PRIOR WRITTEN APPROVAL OF STRUCTURAL ENGINEER.
18. CONCEAL PIPING TO THE GREATEST EXTENT POSSIBLE.
19. INSTRUCT OWNER IN PROPER OPERATION OF SYSTEMS.
20. DRAWINGS DO NOT SHOW ALL OFFSETS WHICH MAY BE REQUIRED. MAKE OFFSETS WITH FITTINGS USING THE LEAST ANGLE OF OFFSET POSSIBLE. PIPING SHALL BE ROUTED TO AVOID ALL STRUCTURAL SUPPORTS, AND
COORDINATED WITH WORK OF OTHER TRADES.
GENERAL NOTES:
1. DEMOLITION: WORK REQUIRED IS NOTED ON PLANS. VERIFY WITH ON SITE CONDITION AND OWNER. SALVAGE
EQUIPMENT FOR OWNER'S USE AS NOTED.
2. COORDINATE INTERRUPTIONS OF SERVICES PASSING THROUGH WORK AREA TO MINIMIZE DISRUPTION IN
ADJACENT SPACES. COORDINATE WITH BUILDING OWNER.
3. INSTALL NEW WORK GENERALLY AS SHOWN. ADEQUATE SPACE HAS BEEN VERIFIED TO THE DEGREE POSSIBLE, BUT MAY REQUIRE MINOR RELOCATION OF SMALL CONDUIT AND CEILING WIRE. COORDINATE
EXTENT OF RELOCATION WITH GENERAL CONSTRUCTION WORK.
4. COORDINATE WORK WITH GENERAL CONSTRUCTION TO MINIMIZE DUST & DUST MIGRATION.
REMODEL CONSTRUCTION NOTES:
1. SANITARY, WASTE, AND VENT PIPING (PLASTIC NOT ALLOWED) SHALL BE NO-HUB CAST IRON OR DWV COPPER.
2. HOT AND COLD WATER PIPING SHALL BE HARD DRAWN COPPER TUBING: TYPE L, ASSEMBLED WITH WROT
COPPER FITTINGS AND LEAD-AND ANTIMONY-FREE SOLDER.
3. INSULATE ALL HOT AND COLD WATER PIPING WITH GLASS FIBER INSULATION WITH ALL SERVICE JACKET. USE
HEAT BONDING TAPE TO CLOSE INSULATION; STAPLES AND PRESSURE TAPE ARE PROHIBITED.
4. PROVIDE ALL REQUIRED ACCESSORIES INCLUDING SHUT-OFFS AND CLEAN-OUTS. PROVIDE COMPONENTS WHICH PREVENT BACK-SIPHONAGE OR CROSS-CONNECTIONS. PROVIDE ISOLATION DEVICES TO REDUCE
SOUND TRANSMISSION.
5. PROVIDE STOPS FOR EACH WATER CONNECTION TO EACH FIXTURE OR ITEM OF EQUIPMENT.
6. DISINFECT WATER DISTRIBUTION SYSTEM. FLUSH AND TEST ALL SYSTEMS FOR PROPER OPERATION. ADJUST
SYSTEM TO PREVENT WATER HAMMER.
7. REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FITTINGS, VALVES, ETC. FLOOR PLANS AND
SECTIONS INDICATE EQUIPMENT LOCATIONS AND GENERAL PIPE ROUTING ONLY.
8. REFER TO CIVIL DRAWINGS FOR UTILITY WORK 5'-0" BEYOND THE BUILDING LINE.
PIPING NOTES:
A AIR
AFF ABOVE FINISHED FLOOR
ARRGT ARRANGEMENT
ATM ATMOSPHERE
BFF BELOW FINISHED FLOOR
BFP BACKFLOW PREVENTER
BHP BRAKE HORSEPOWER
BLDG BUILDING
BOB BOTTOM OF BEAM
BOS BOTTOM OF STEEL
BTUH BRITISH THERMAL UNITS PER HOUR
CAP CAPACITY
CFM CUBIC FEET PER MINUTE
CI CAST IRON
CLG CEILING, COOLING
CNTFGL CENTRIFUGAL
CO CLEANOUT
CONC CONCRETE
COND CONDENSATE
CONT CONTINUE, CONTROL
COMP COMPRESSOR
CP CIRCULATING PUMP
CTG CLEANOUT TO GRADE
CU FT CUBIC FEET
CV CONSTANT VOLUME
CW COLD WATER
dB DECIBELS
DCVA DOUBLE CHECK VALVE ASSEMBLY
DEG DEGREE
DF DRINKING FOUNTAIN
DI DE-IONIZED
DIA DIAMETER
DN DOWN
DS DOWNSPOUT
E EXISTING
EER ENERGY EFFICIENCY RATING
EFF EFFICIENCY
EL ELEVATION
EQUIP EQUIPMENT
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
EXH EXHAUST
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR, EXTERNAL
F FAHRENHEIT, FIRE LINE
FD FIRE DAMPER, FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FLA FULL LOAD AMPS
FLR FLOOR
FLTR FILTER
FM FLOW METER
FPM FEET PER MINUTE
FPS FEET PER SECOND
FT FEET
FV FACE VELOCITY
GA GAGE
GAL GALLONS
GALV GALVANIZED
GPM GALLONS PER MINUTE
H HEIGHT
HB HOSE BIBB
HC HEATING COIL
HD HEAD
HEX HEAT EXCHANGE
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER, HEAT PUMP
HPS HIGH PRESSURE STEAM
HW HOT WATER
HWC HOT WATER CIRCULATING
HWP HOT WATER PUMP
HWR HEATING WATER RETURN
HWS HEATING WATER SUPPLY
HZ HERTZ
ABBREVIATIONS
IDE DIAMETER, INDIRECT DRAIN
IE INVERT ELEVATION
IN INCH
INIT INITIAL
INT INTERIOR
IPLV INTEGRATED PART LOAD VALUE
KW KILOWATT
KWH KILOWATT HOURS
L LENGTH
LAT LEAVING AIR TEMPERATURE
LB POUND, LINEAR BAR
LBS POUNDS
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MBH THOUSAND BTU PER HOUR
MCA MINIMUM CIRCUIT AMPACITY
MD MANUAL DAMPER
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MTR MOTOR
NC NORMALLY CLOSED
NEG NEGATIVE
NIC NOT IN CONTRACT
NO NUMBER, NORMALLY OPEN
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
ORD OVERFLOW ROOF DRAIN
ORL OVERFLOW RAIN LEADER
P PUMP, PLUMBING
PD PRESSURE DROP
PH PHASE
POC POINT OF CONNECTION
POS POSITIVE
P/T PRESSURE/TEMPERATURE
PVC POLYVINYL CHLORIDE
QTY QUANTITY
RD ROOF DRAIN
REF REFERENCE
REQD REQUIRED
RL RAIN LEADER
RPBFP REDUCED PRESSURE BACKFLOW PREVENTER
RPM REVOLUTIONS PER MINUTE
S SOIL
SD STORM DRAIN, SMOKE DAMPER
SPR SPRINKLER
SS STAINLESS STEEL, SANITARY SEWER
STP STANDPIPE
TEMP TEMPERATURE
TOT TOTAL
TP TRAP PRIMER, TOTAL PRESSURE
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
V VENT, VOLT
VA VALVE
VEL VELOCITY
VFD VARIABLE FREQUENCY DRIVE
VTR VENT THROUGH ROOF
W WASTE, WATER, WATT, WIDTH
WG WATER GAGE
WH WATER HEATER, WALL HYDRANT
WTR WATER
SYMBOLS LEGEND - GENERAL
DESCRIPTIONSYMBOL
X-XX
X
XX.XX
X
XX.XX
X
XX.XX
N
DRAWING CONSTRUCTION ("FLAG") NOTE
EQUIPMENT IDENTIFIER
MATCHLINE
REVISION CLOUD (ENCIRCLES DRAWING CHANGES MADE SINCE THE
PREVIOUS RELEASE)
REVISION REFERENCE
EXISTING TO BE REMOVED (HATCH)
HEAVY LINEWEIGHT INDICATES NEW WORK
LIGHT LINEWEIGHT INDICATES EXISTING INFORMATION
POINT OF CONNECTION
DETAIL REFERENCE
DETAIL IDENTIFICATION NUMBER
SHEET WHERE DETAIL IS DRAWN
ELEVATION REFERENCE
ELEVATION IDENTIFICATION
NUMBER SHEET WHERE ELEVATION IS DRAWN
SECTION REFERENCE SECTION
IDENTIFICATION NUMBER
SHEET WHERE SECTION IS DRAWN
NORTH REFERENCE
SYMBOLS LEGEND - PIPING
DESCRIPTIONSYMBOL
MAV AAV
SOIL OR WASTE
VENT
RAIN LEADER
OVERFLOW RAIN LEADER
INDIRECT DRAIN
COLD WATER
HOT WATER
HOT WATER CIRCULATING
140° POTABLE HOT WATER
120° POTABLE HOT WATER
FIRE
SPRINKLER
STANDPIPE
HIGH PRESSURE STEAM
REDUCER, CONCENTRIC
WYE STRAINER WITH CAPPED HOSE END BLOWDOWN VALVE
ANGLE VALVE
AUTOMATIC CONTROL VALVE - TWO WAY (PNEUMATIC OPERATOR
SHOWN)
AUTOMATIC CONTROL VALVE - THREE WAY (ELECTRIC OPERATOR
SHOWN)
BUTTERFLY VALVE
FLEXIBLE CONNECTION IN PIPING
MANUAL AIR VENT (MAV), AUTOMATIC AIR VENT (AAV)
PRESSURE GAUGE
THERMOMETER
THERMOMETER WELL
SIGHT GLASS
HOSE BIB
V
RD
OD
ID
140º HW
120º HW
F
SPR
STP
HPS
M
SYMBOLS LEGEND - PIPING
DESCRIPTIONSYMBOL
A
PS
P/T
PIPE ANCHOR
PIPE ALIGNMENT GUIDE
CONTROL VALVE STATION
PIPE SUPPORT
PRESSURE/TEMPERATURE TEST PORT
CAP
UNION
WYE STRAINER
GATE VALVE
GLOBE VALVE
BALL VALVE
BALANCING OR PLUG VALVE
PRESSURE REDUCING VALVE
BALANCING/MEASURING VALVE
RELIEF VALVE
CHECK VALVE
PIPE TURNING DOWN / AWAY
PIPE TURNING UP / TOWARDS
PIPE DOWN TEE
PIPE DOWN TEE / AWAY
PIPE UP TEE / TOWARDS
PLUG
SYMBOLS LEGEND - PIPING & AIRFLOW DIAGRAMS
DESCRIPTIONSYMBOL
M
M
PUMP
CENTRIFUGAL FAN
ELECTRIC MOTOR/STARTER ASSEMBLY
ELECTRIC MOTOR OPERATOR (VALVES AND DAMPERS)
FLOOR DRAIN
FUNNEL DRAIN
FLOW DIRECTION
FLOOR SINK (SQUARE AND ROUND)
PROJECT NO.:
ISSUE DATE:
REVISIONS:
C
LA
R K
K
JO
S A
R C
H
IT
E C
T S
LL
C
O
P Y
R
IG
H T
S W
A ld er S t., S ui te
P or tla nd
, O R
P h on e:
3/
4-
111 SW Fifth Ave, Ste 2120 Portland, Oregon 97204
Tel 503.416.2400 Fax 206.267.1701
SAZAN# 257-20047
/2
/2
:3
:3
A M
GENERAL NOTES,
ABBREVIATIONS AND
SHEET INDEX
04.02.21
P0.00
IS
S
U E
D F
O R
P E
R M
IT
20018
O A
K C
R E
E K
E X
P A
N S
IO
N
L O
C H
N E
R R
D S
E A
L B
A N
Y
O R
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y
PLUMBING SHEET INDEX
P0.00 GENERAL NOTES, ABBREVIATIONS AND SHEET INDEX
P0.01 PLUMBING SCHEDULES
PD1.01 PLUMBING DEMOLITION - FLOOR PLAN
P2.00 PLUMBING UNDERGROUND PLAN
P2.01 PLUMBING WASTE & VENT, ROOF DRAIN - FLOOR PLAN
P3.01 PLUMBING DOMESTIC WATER - FLOOR PLAN
P4.00 PLUMBING DETAILS
Expires: 06/30/22
PROJECT NO.:
ISSUE DATE:
REVISIONS:
C
LA
R K
K
JO
S A
R C
H
IT
E C
T S
P Y
R
IG
H T
S W
A ld e r
S t., S u ite
P or tla nd
, O R
P h on e:
3/
4-
111 SW Fifth Ave, Ste 2120 Portland, Oregon 97204
Tel 503.416.2400 Fax 206.267.1701
SAZAN# 257-20047
/2
/2
:3
:3
A M
PLUMBING SCHEDULES
04.02.21
P0.01
IS
S
U E
D F
O R
P E
R M
IT
20018
O A
K C
R E
E K
E X
P A
N S
IO
N
L O
C H
N E
R R
D S
E A
L B
A N
Y
O R
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y
1. COORDINATE MOUNTING HEIGHTS WITH ARCHITECTURAL DRAWINGS.
REMARKS:
WC-2
WATER CLOSET, FLOOR MOUNTED,
FLUSH VALVE
4 2 1 -- -- --
ACORN PENAL-WARE SIPHON JET FLOOR OUTLET TOILET 1695-W-3-1.28GPF-FVBO-SPS-EG WHITE, WITH STAINLESS STEEL ACCESS PANEL FOR FLUSH VALVE ACCESS. SLOAN ROYAL CONCEALED MANUAL HYDRAULIC FLUSHOMETER, 940-1.28-2-10-3/4-LDIM WITH NY-108-1
PENAL WARE METAL PUSH BUTTON.
WC-1
WATER CLOSET, FLOOR MOUNTED,
FLUSH VALVE
4 2 1 -- -- --
AMERICAN STANDARD 3351.101, AFWALL, VITREOUS CHINA, 1.1 - 1.6 GPF, WALL MOUNTED, ELONGATED BOWL, FULLY GLAZED TRAPWAY, SIPHON JET, 1 1/2" TOP INLET SPUD, ADA COMPLIANT. FLUSH VALVE: SLOAN ROYAL 111 DFSM-1.6/1.1, DUAL FLUSH - 1.6 GPF/1.1 GPF.
SEAT: CHURCH MODEL 9500C, OPEN FRONT, WHITE.
TPV-1 TRAP PRIMER -- -- 1/2 -- -- -- PRECISION PLUMBING PRODUCT MODEL PR-500. PRIME DRAINS USING DU-4/DU-U DISTRIBUTION SYSTEM.
TMV-1 THERMOSTATIC MIXING VALVE -- -- 1/2 1/2 1/2 -- WATTS HYDROGUARD SERIES LFLM495-2, SWEAT UNION CONNECTIONS, INTEGRAL CHECKS AND SCREENS.
S-1 SINK 2 2 1/2 1/2 -- --
ELKAY LRAD191855 (19"X17"X5 1/2"), 8-INCH CENTER-CENTER HOLES FOR FAUCET. FAUCET: CHICAGO FAUCETS 786-GN2BVBCP, 6" GOOSENECK SPOUT WITH ATMOSPHERIC VACUUM BREAKER WITH PRESSURE COMPENSATING NON AERATING LAMINAR SPRAY.
MCGUIRE STOPS, SUPPLIES, TRAP. PROVIDE ADA WRAP FOR STOPS, SUPPIES, TRAP. PROVIDE WITH TMV-1
L-2 LIGATURE RESISTANT LAVATORY 2 2 1/2 1/2 -- --
ACORN DURA-WARE 1953-9-H1-GT-TE ADA COMPLIANT, 18" 16 GA STAINLESS STEEL LAVATORY WITH SINGLE HOLE PUNCHING, AND TRAP ENCLOSURE. CHICAGO FAUCETS ELR-E12A-42ABCP. MCGUIRE STOPS, SUPPLIES, TRAP. PROVIDE VANDAL RESISTANT BOLTS WHEN
MOUNTING SINK AND TRAP/ANGLE STOPS COVER. PROVIDE ONE COMMANDER UNIT.
L-1 LAVATORY 2 2 1/2 1/2 -- --
AMERICAN STANDARD LUCERN WALL HUNG LAVATORY, 0356.521, 8" C-C FAUCET HOLES, WALL HANGER COMPLIANT. PROVIDE IN-WALL FLOOR MOUNTED SUPPORT. CHICAGO FAUCETS 786-GN2BVBCP FAUCET WITH PRESSURE COMPENSATING NON-AERATING LAMINAR SPRAY. MCGUIRE STOPS, SUPPLIES, TRAP. PROVIDE ADA WRAP FOR STOPS, SUPPLIES, TRAP,TMV. PROVIDE WITH TMV-1.
RPBP-1
REDUCED PRESSURE BACKFLOW
PREVENTER
-- -- 3/4 -- -- -- WATTS 009 WITH FACTORY DRAIN FITTING. PIPE DRAIN FITTING TO ADJACENT FS-1.
HB-2 EXTERIOR HOSE BIBB - - 3/4 - - -
WOODFORD MODEL RB65, ROUND AUTOMATIC DRAINING WITH ANTI-SIPHON VACUUM BREAKER, CHROME PLATED, LOOSE KEY LOCK
COVER.
HB-1 HOSE BIBB - - 3/4 - - -
WOODFORD MODEL 21, MILD CLIMATE, NO VACUUM BREAKER. MOUNT DOWNSTREAM OF RPBP-1. MOUNT 48 INCHES ABOVE FINISHED
FLOOR.
FS-1 FLOOR SINK 3 2 -- -- -- --
JR SMITH 3150Y-12 12"X12"X8" DEEP WITH NICKEL BRONZE GRATE AND FRAME, WHITE ACID RESISTING EPOXY COATED INTERIOR AND TOP, ANCHOR FLANGE, 1/2 GRATE, TRAP PRIMER CONNECTION, WHITE ARC ANTI-SPLASH INTERIOR BOTTOM DOME STRAINER. PRIME.
FD-2 LIGATURE RESISTANT FLOOR DRAIN 3 2 WILLOUGHBY INDUSTRIES LRFD-6RD-3-NH, 6" COVER, 3" OUTLET, NO HUB OUTLET.
FD-1 FLOOR DRAIN 2 2 -- -- -- --
ZURN MODEL #Z415B, CAST IRON BODY, 5" DIAMETER ADJUSTABLE NICKEL BRONZE STRAINER. PROVIDE WITH 1/2" TRAP PRIMER
CONNECTION.
EEW-1 EMERGENCY EYE WASH -- -- 1/2 1/2 1/2 GUARDIAN G1750P, WALL MOUNTED. DRAIN TO ADJACENT FLOOR SINK. PROVIDE G3600LF TEMPERING VALVE.
DN-1 DOWNSPOUT NOZZLE 4 -- -- -- -- -- J R SMITH 1770, THREADED OR NO HUB OUTLET AT CONTRACTOR'S OPTION
W V CW HW TW GAS
MARK DESCRIPTION
ROUGH-IN CONNECTION (IN)
REMARKS
PLUMBING FIXTURE SCHEDULE
watercalc...
HOT WATER TO BUILDING, WH-3 1 1/2"
HOT WATER TO BUILDING, WH-1, WH-2 2"
COLD WATER MAIN 2 1/2"
TOTAL GPM/BUILDING 100.00 65.00
TOTAL 389.50 207.75
42 WATER CLOSET 2.50 105.00 0.00
10 WB-1 (CLOTHESWASHER) 4.00 40.00 30.00
8 SHOWER 2.00 16.00 12.00
1 MOP SINK 3.00 3.00 2.25
42 LAVATORY 1.00 42.00 31.50
1 LAUNDRY TRAY 2.00 2.00 1.50
29 KITCHEN SINK 2.00 58.00 43.50
5 HOSE BIBB 1.00 5.00 0.00
1 HOSE BIBB 2.50 2.50 0.00
29 BATHTUB/SHOWER 4 116.00 87.00
DOMESTIC DEMAND
ITEM DESCRIPTION
PUBLIC
GENERAL
USE
TOTAL
UNITS
(.75)
HOT
WATER
ONE BUILDING
WATER SERVICE CALCULATION
1. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. PROVIDE OPTIONAL DIGITAL TIMER. SUSPEND PUMP INDEPENDENT OF PIPING.
REMARKS:
RCP-1 HOT WATER RECIRC GENERAL BUILDING GRUNDFOS 15-35SUC INLINE 3 120/1/60 SEE NOTE 1
FLA EACH V/PH/HZ
EQUIP. NO LOCATION SERVICE
BASIS OF DESIGN
MANUFACTURER
BASIS OF DESIGN
MODEL NUMBER
DESCRIPTION GPM
ELECTRICAL
REMARKS
EQUIPMENT SCHEDULE
B
A
C
(E) L-1
(E) L-2
(E) SH-1
(E) WC-2
(E) S-2
(E) S-2
(E) L-2(E) WC-1
(E) HB-1
OFFICE
(E)
ENGINEERING
(E)
EMERGENCY
GENERATOR
(E)
(E)2 1/2" CW
(E)1 1/4" HW
(E)3/4" HWC
(E)2" NG
2 1/2" CW
(E)3/4" HWC
(E )1
/2
C
W (E
)3 /4
H
W
(E )2
V
(E )2
V
(E )3
/4
H W
(E )3
/4
C W
(E)1 1/2" CW
(E)3/4" HW
(E) 4" RD UP
(E) 4" OD UP
(E)3/4" CW
(E)3" V
1 1
(E)6" W
(E)4" W
(E)4" W
(E)4" W
(E)4" W
(E)6" W
(E)6" W
IE=-7.59'
(E) FD-1
(E) FD-1
(E) FD-1
(E)1 1/4" HW
PROJECT NO.:
ISSUE DATE:
REVISIONS:
C
LA
R K
K
JO
S A
R C
H
IT
E C
T S
P Y
R
IG
H T
S W
A ld e r
S t., S u ite
P or tla nd
, O R
P h on e:
3/
4-
111 SW Fifth Ave, Ste 2120 Portland, Oregon 97204
Tel 503.416.2400 Fax 206.267.1701
SAZAN# 257-20047
/2
/2
:3
:4
A M
PLUMBING DEMOLITION
- FLOOR PLAN
04.02.21
PD1.01
IS
S
U E
D F
O R
P E
R M
IT
20018
O A
K C
R E
E K
E X
P A
N S
IO
N
L O
C H
N E
R R
D S
E A
L B
A N
Y
O R
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y
1/4" = 1'-0"PD1.01
1 PLUMBING DEMOLITION - FIRST FLOOR PLAN
SHEET NOTE
A. ENTIRE HOT WATER SYSTEM WILL BE REPLACED.
FLAG NOTES
1. DEMOLISH EXISTING FIXTURE. CAP WASTE PIPING BELOW FLOOR IN A PERMANENT
MANNER. CAP VENT LINE ABOVE CEILING. REMOVE COLD WATER PIPING AND CAP AT
MAIN. DEMO HOT WATER PIPING.
2. DEMOLISH EXISTING FIXTURE. CAP WASTE LINE BELOW FLOOR FOR FUTURE
CONNECTION. CAP VENT LINE FOR FIXTURE CONNECTION. CAP COLD WATER ABOVE
CEILING FOR FUTURE CONNECTION. DEMO HOT WATER PIPING.
3. DEMO OD DROP IN WALL AND PREPARE FOR FUTURE CONNECTION. EXCAVATE
UNDERGROUND ROOF DRAIN PIPING TO A POINT 6 FEET OUT FROM EXISTING
BUILDING. IF PIPING TYPE IS APPROVED FOR USE WITHIN BUILDING PER OSPC TABLE
101.2 IT MAY REMAIN IN PLACE. IF NOT REPLACE WITH APPROVED PIPING.
4. DEMO HOSE BIBB AND PIPING. CAP FOR THE FUTURE CONNECTION.
B
A
C
(E )4
W
(E)4" W(E)4" W(E)4" W(E)4" W
(E )6
W
(E )6
W
1" MV
(E)6" W
IE=-7.59'
(E )4
W
4" W
(E )4
W
1/2" CA 2
3" W UP
2" W UP
4" W UP
2" W UP
4" W UP
2" W UP
4" W UP
4" W TO FD-2
4" W UP TO FD-1
1" MV
1/2" CA
4" RD
PROJECT NO.:
ISSUE DATE:
REVISIONS:
C
LA
R K
K
JO
S A
R C
H
IT
E C
T S
P Y
R
IG
H T
S W
A ld er S t., S ui te
P or tla nd
, O R
P h on e:
3/
4-
111 SW Fifth Ave, Ste 2120 Portland, Oregon 97204
Tel 503.416.2400 Fax 206.267.1701
SAZAN# 257-20047
/2
/2
:0
:4
P
M
PLUMBING
UNDERGROUND PLAN
04.02.21
P2.00
IS
S
U E
D F
O R
P E
R M
IT
20018
O A
K C
R E
E K
E X
P A
N S
IO
N
L O
C H
N E
R R
D S
E A
L B
A N
Y
O R
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y
1/4" = 1'-0"P2.00
1 PLUMBING UNDERGROUND PLAN
FLAG NOTES
1. DRAIN FOR MEDICAL EQUIPMENT.
2. CONNECTION LOCATED IN FLOOR BOX AT FOOT OF CHAIR.
3. 1/2" CA AND 1" DENTAL VACUUM UP. COOERDINATE LOCATION WITH DENTAL
EQUIPMENT.
4. POINT OF CONNECTION TO EXISTING 4-INCH ROOF DRAIN PIPING.
5. SEPARATELY SLEEVE MV AND CA PIPING. SLEEVING SHALL BE 2-INCH ELECTRIC
CONDUIT USING MIN. 24" RADIUS ELBOWS.
1 Addendum 1 06-01-21
B
A
C
57 SF
STAFF TLT
63 SF
FILE STORAGE
142 SF
MED EXAM
71 SF
DENTAL UTILITY
59 SF
OFFICE
87 SF
PSYCH OFFICE
107 SF
PSYCH OFFICE
108 SF
DENTAL EXAM
58 SF
MED UTILITY
45 SF
PAT TLT
45 SF
SOILED HOLDING/
POCT
144 SF
NURSE STATION
291 SF
HALLWAY
67 SF
WAITING
S-1
WC-2
WC-1
L-2
S-1 S-1
L-1
S-1
S-1
FD-1
(E)4" RD (E)4" OD
(E )2
V (E
)2
V
DN-1
2" V
2" V
2" V
3" FS-1
(E)3" V
2" V
4" WCO
FD-2
EEW-1
EMERGENCY
GENERATOR
(E)
ELECTRICAL
ENGINEERING
(E)
OFFICE
(E)
2" V
PROJECT NO.:
ISSUE DATE:
REVISIONS:
C
LA
R K
K
JO
S A
R C
H
IT
E C
T S
P Y
R
IG
H T
S W
A ld e r
S t., S u ite
P or tla nd
, O R
P h on e:
3/
4-
111 SW Fifth Ave, Ste 2120 Portland, Oregon 97204
Tel 503.416.2400 Fax 206.267.1701
SAZAN# 257-20047
/2
/2
:3
:3
A M
PLUMBING WASTE &
VENT, ROOF DRAIN -
FLOOR PLAN
04.02.21
P2.01
IS
S
U E
D F
O R
P E
R M
IT
20018
O A
K C
R E
E K
E X
P A
N S
IO
N
L O
C H
N E
R R
D S
E A
L B
A N
Y
O R
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y
1/4" = 1'-0"P2.01
1 PLUMBING WASTE & VENT, ROOF DRAIN FOOR PLAN
FLAG NOTES
1. DROP 4" RD IN WALL. SEE P2.00.
2. CONNECT DENTAL AIR AND DENTAL VACUUM TO OWNER FURNISHED EQUIPMENT.
PROVIDE SHUT OFF VALVES RATED FOR SERVICE. USE ONLY TAPE JOINT SEALANT
FOR THESE SERVICES. PIPE JOINT COMPOUND (DOPE) IS PROHIBITED.
9A
B
A
C
7A
8A
57 SF
STAFF TLT
63 SF
FILE STORAGE
142 SF
MED EXAM
71 SF
DENTAL UTILITY
59 SF
OFFICE
87 SF
PSYCH OFFICE
107 SF
PSYCH OFFICE
108 SF
DENTAL EXAM
58 SF
MED UTILITY
45 SF
PAT TLT
45 SF
SOILED HOLDING/
POCT
144 SF
NURSE STATION
291 SF
HALLWAY
67 SF
WAITING
S-1
WC-2
WC-1
L-2
S-1 S-1
L-1
S-1
S-1
2 1/2" CW
(E)3/4" HWC
(E)2 1/2" CW
(E )1
/2
C
W
HB-2
1 1/4" HW
1 1/2" CW
1/2" CW
1/2" CW
1 1/2" CW TO WC-2
RPBP-11
3/4" CW
HB-1
EEW-1
(E)2" NG
3/4" HWC
1 1/4" 140º HW
3/4" HWC
1" HW
3/4" HW
3/4" HW
DOMESTIC HOT
WATER AND
SPRINKLER RISER
(E)
ELECTRICAL
(E)
ENGINEERING / SHOP
(E)
ELECTRICAL
EMERGENCY
GENERATOR
(E)
ENGINEERING
(E)
OFFICE
(E)
RCP-1
140º HW
P4.00
TPV-1
1/2" CW
1/2" HW
PROJECT NO.:
ISSUE DATE:
REVISIONS:
C
LA
R K
K
JO
S A
R C
H
IT
E C
T S
P Y
R
IG
H T
S W
A ld e r
S t., S u ite
P or tla nd
, O R
P h on e:
3/
4-
111 SW Fifth Ave, Ste 2120 Portland, Oregon 97204
Tel 503.416.2400 Fax 206.267.1701
SAZAN# 257-20047
/2
/2
:3
:3
A M
PLUMBING DOMESTIC
WATER - FLOOR PLAN
04.02.21
P3.01
IS
S
U E
D F
O R
P E
R M
IT
20018
O A
K C
R E
E K
E X
P A
N S
IO
N
L O
C H
N E
R R
D S
E A
L B
A N
Y
O R
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y
1/4" = 1'-0"P3.01
1 PLUMBING DOMESTIC WATER - FIRST FLOOR PLAN
SHEET NOTE:
A. HOT WATER IS CIRCULATED TO THE ANGLE STOP AT EACH FIXTURE.
B. DOUBLE CHECK VALVE BACKFLOW PREVENTER ON ALL DOMESTIC WATER SERVING
THE CLINIC.
FLAG NOTES:
1. 3/4" REDUCED PRESSURE BACKFLOW PREVENTER.
2. FIELD ROUTE 1 1/4" HW AND 3/4" HWR TO EXISTING HOT WATER HEATER. PROVIDE
NEW HOT WATER RECIRC PUMP, RCP-1.
3. THERMOSTATIC MIXING VALVE TO BE LOCATED AT EACH SINK. SEE DETAIL 3 / P4.00.
4. WATER HEATERS ARE EXISTING.
5. PROVIDE SOV ON DROP.
CLEANOUT BOXFLOOR COVER
CLEANOUT PLUG
UNDERGROUND DRAIN PIPING
C.I. NO-HUB CPLG.
SPEEDY SEAL OR
FERNCO CPLG.
COORDINATE SETTING
OF GRATE FLUSH WITH
FLOOR
STRUCTURAL SLAB
TY-SEAL
ATTACHMENT
WATER-PROOF
MEMBRANE
CONCRETE FILL
CEMENT BED
TILE FLOOR
M
CH
TEMPERING VALVE
TEMPERING VALVE
M
C
H
(N) 1" HWC
(E) HWC
RCP-1
CONNECT TO EXISTING COLD
WATER SUPPLY TO EXISTING
WATER HEATERS DOWNSTREAM
OF SHUT OFF AND CHECK VALVES
PROVIDE NEW BALANCING,
CHECK AND SHUT OFF VALVES
ON EXISTING HWC PIPING
PROJECT NO.:
ISSUE DATE:
REVISIONS:
C
LA
R K
K
JO
S A
R C
H
IT
E C
T S
P Y
R
IG
H T
S W
A ld er S t., S ui te
P or tla nd
, O R
P h on e:
3/
4-
111 SW Fifth Ave, Ste 2120 Portland, Oregon 97204
Tel 503.416.2400 Fax 206.267.1701
SAZAN# 257-20047
/2
/2
:0
:5
P
M
PLUMBING DETAILS
04.02.21
P4.00
IS
S
U E
D F
O R
P E
R M
IT
20018
O A
K C
R E
E K
E X
P A
N S
IO
N
L O
C H
N E
R R
D S
E A
L B
A N
Y
O R
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y
12" = 1'-0"
FLOOR CLEANOUT DETAIL
12" = 1'-0"
FLOOR DRAIN DETAIL
1 Addendum 1 06-01-21
12" = 1'-0"
THERMOSTATIC MIXING VALVE DETAIL
12" = 1'-0"
HWC SCHEMATIC
| Sheets |
| P0.00 - GENERAL NOTES, ABBREVIATIONS AND SHEET INDEX |
| P0.01 - PLUMBING SCHEDULES |
| PD1.01 - PLUMBING DEMOLITION - FLOOR PLAN |
| P2.00 - PLUMBING UNDERGROUND PLAN |
| P2.01 - PLUMBING WASTE & VENT, ROOF DRAIN - FLOOR PLAN |
| P3.01 - PLUMBING DOMESTIC WATER - FLOOR PLAN |
| P4.00 - PLUMBING DETAILS |
File details come from the government source that posted it. Updated .