A5.01-INTERIOR_ELEVATIONS~1.pdf
PDF 1 MB Posted
- Attached to
- OCYCF Med/Dental Remodel
- Solicitation number
- S-DASOBO-00001190
- Issued by
- Lake County, Albany City, Oregon
About this file
This document appears to be a set of interior elevation drawings for the OCYCF Med/Dental Remodel Project in Albany, Oregon. The project is being managed by the Oregon Youth Authority and encompasses renovation work in several rooms, including waiting areas, nurse stations, dental exam rooms, medical exam rooms, and staff restrooms. The drawings provide detailed specifications for the placement of various equipment and fixtures, such as computers, refrigerators, sinks, and storage cabinets, within these spaces.
The related state and local contract opportunity indicates that this project is an Invitation to Bid (ITB) for the OCYCF Med/Dental Remodel, which will be awarded to a contractor to perform the construction work. The project is located in Albany, Oregon, within the jurisdictions of Linn County and the City of Albany. No additional details about the pricing terms, set-asides, funding sources, or other salient information are provided in the given materials.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CD
A7.01
A7.01
A7.01
A7.01
AEDE
A7.01
A7.01
CPU
DC
A7.01
A7.01
A7.01
A7.01
CPUCPUCPU
F
2'-2 3/4" EQ EQ
3' -0
1'
-6
2' -6
A7.01
A7.01
1'-5 1/4" 2'-10" 2'-10"
REF-U
MICRO
PTD
SD
T
SCD
MIR
SND TPD
GLD
2' -0
2'
-0
3' -0
2'-6" 5'-10 3/4"
CPUSD
PTD
XRAY
EQ EQ EQ
EQ EQ EQ
A7.01
A7.01
A7.01
A7.01
HS
3' -0
4'
-0
EQ EQ EQ
7'-9 1/4"
SD
PTD
GLD
USC
EQ EQ
SHP
A7.01
A7.01
A7.01
2'-6"
1'-8 1/4" 2'-6"
3'-0" 4'-2 1/4"
ATC
A7.01
A7.01
A7.01
EQ EQ
1' -6
2'
-6
PTD
SD GLD
EQ EQ
A7.01
A7.01 6
A7.01
SHP
DP MAYO
T
WMC
EQ EQ EQ
2' -6
1'
-6
3' -0
1'-6" EQ EQ 1'-6"
8'-8 3/4"
A7.01
A7.01
A7.01
HS
EQ EQ EQ
7'-8 1/4"
2' -0
6"
1' -6
3'
-0
1'-7"
PTD
GLD SD
CT-SP
SHP
A7.01
A7.01
A7.01
CLR.
2'-6"
3' -0
2'
-0
/4
2'-10"
REF
2'-9" 1'-9 1/2"
A7.01
A7.01
OFOI - OWNER FURNISHED, OWNER INSTALLED
LEGEND
OFCI - OWNER FURNISHED, CONTRACTOR INSTALLED
CFCI - CONTRACTOR FURNISHED, CONTRACTOR
INSTALLED
UNDER CABINET LIGHT FIXTURE
VENDOR FURNISHED EQUIPMENT
3' -0
PASS
3'-6 1/4"
A7.01
3' -0
2'
-0
2' -0
CNMS
EQ EQ
SHP
GLDPTD
SD
2'-6"
REF-U
A7.01
A7.01
EW
SC
PRPR
PTD
SDSCD
T
MIR
SND TPD
A7.01
3'-0"
7' -0
PROJECT NO.:
ISSUE DATE:
REVISIONS:
C
LA
R K
K
JO
S A
R C
H
IT
E C
T S
LL
C
C
O P
Y R
IG
H
T
S W
A ld er S t., S ui te
P or tla nd
, O R
P ho ne
: 5
/2
-4
/1
/2
:2
:2
A
M
INTERIOR ELEVATIONS
4.2.21
A5.01
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
20018
O A
K C
R E
E K
E X
P A
N S
IO
N
L
O C
H N
E R
R D
S E
A
L B
A N
Y O
R
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y
3/8" = 1'-0"A5.01
1 100 WAITING (E)
3/8" = 1'-0"A5.01
2 100 WAITING (N)
3/8" = 1'-0"A5.01
5 101 NURSE STATION (N)
3/8" = 1'-0"A5.01
6 101 NURSE STATION (W)
3/8" = 1'-0"A5.01
7 101 NURSE STATION (S)
3/8" = 1'-0"A5.01
9 102 FILE STORAGE (E)
3/8" = 1'-0"A5.01
24 111 PAT TLT (N)
3/8" = 1'-0"A5.01
25 111 PAT TLT (W)
3/8" = 1'-0"A5.01
10 104 DENTAL EXAM (S)
3/8" = 1'-0"A5.01
11 104 DENTAL EXAM (E)
3/8" = 1'-0"A5.01
12 104 DENTAL EXAM (N)
3/8" = 1'-0"A5.01
13 104 DENTAL EXAM (W)
3/8" = 1'-0"A5.01
14 103 DENTAL UTILITY (S)
3/8" = 1'-0"A5.01
15 103 DENTAL UTILITY (E)
3/8" = 1'-0"A5.01
19 109 MED EXAM (S)
3/8" = 1'-0"A5.01
18 109 MED EXAM (W)
3/8" = 1'-0"A5.01
17 109 MED EXAM (N)
3/8" = 1'-0"A5.01
16 109 MED EXAM (E)
3/8" = 1'-0"A5.01
20 110 MED UTILITY (N)
3/8" = 1'-0"A5.01
21 110 MED UTILITY (W)
EQUIPMENT LEGEND
AED AED BOX
ATC AUTOCLAVE
CN CENTRIFUGE
CPU COMPUTER
CT-SP SUPPLY CART
DP DUAL ADJUSTABLE PULLEY
EW EYE WASH
GLD GLOVE DISPENSER
HS HAND SANITIZER
MAYO MAYO STAND
MICRO MICROWAVE
MIR MIRROR
MS MICROSCOPE
PASS SPECIMEN PASS-THRU DOOR
PR PRINTER
PTD PAPER TOWEL DISPENSER
REF REFRIGERATOR
REF-U UNDERCOUNTER REFRIGERATOR
SC SCALE
SCD SEAT COVER DISPENSER
SD SOAP DISPENSER
SHP SHARPS CONTAINER
SND SANITARY NAPKIN DISPENSER
T TRASH CAN
TPD TOILET PAPER DISPENSER
USC ULTRASONIC CLEANER
WMC WALL MOUNTED COMPUTER
XRAY XRAY2GO MINI
GENERAL NOTES
1. CABINETMAKER SHALL COORDINATE WITH OTHER TRADES,
VENDORS AND OWNER FOR ITEMS INSTALLED IN AND AROUND
CABINETRY
2. GROMMETS AND ELECTRICAL OUTLETS: INSTALL GROMMETS IN
COUNTERTOPS FOR ALL UNDER-COUNTER OUTLETS AS FOLLOWS:
1 1/2" DIA. GROMMET FOR UP TO 2 OUTLETS
2 1/2" DIA. GROMMET FOR UP TO 4 OUTLETS
3. COORDINATE MOUNTING HEIGHTS FOR ALL SIGNAGE, EQUIPMENT
AND FIXTURES WITH STANDARD MOUNTING HEIGHT DRAWING.
4. PRIOR TO COVERING WALL, BACKING SHALL BE PROVIDED TO
ACCOMODATE ALL HUNG ITEMS AND ACCESSORIES CALLED FOR ON
THE CONSTRUCTION DOCUMENTS. SUCH ITEMS CONSIST OF, BUT
ARE NOT LIMITED TO: UPPERCASE CABINETS, STORAGE SHELVING,
TELEVISIONS, COMPUTER MONITORS, LAVATORY ACCESSORIES,
AND FUTURE INSTALLATION OF GRAB BARS AT THE SIDES OF WATER
CLOSETS.
3/8" = 1'-0"A5.01
22 112 SH/POCT (N)
3/8" = 1'-0"A5.01
23 112 SH/POCT (W)
3/8" = 1'-0"A5.01
8 101 NURSE STATION (E)
3/8" = 1'-0"A5.01
26 108 STAFF TLT (S)
3/8" = 1'-0"A5.01
27 108 STAFF TLT (E)
3/8" = 1'-0"A5.01
36 102 FILE STORAGE (W)
| Sheets |
| A5.01 - INTERIOR ELEVATIONS |
File details come from the government source that posted it. Updated .