This document provides details on a federal contract opportunity for expansion of a parking structure at a Veterans Affairs community-based outpatient clinic in Joliet, Illinois. The solicitation number is 36C77624B0009 and is seeking proposals to expand the existing parking structure to add approximately 150 additional parking spaces. The opportunity was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas. Interested parties should submit proposals in response to the revised solicitation by the upcoming deadline in order to be considered for the contract award scheduled for later this year. The contract aims to address parking capacity issues at the outpatient clinic through expanding the current parking facility.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABBREVIATIONS
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AL ALUMINUM
ALT ALTERNATE
AP ACCESS PANEL
APD AIR PRESSURE DROP
BAS BUILDING AUTOMATION SYSTEM
BHP BRAKE HORSEPOWER
BLDG BUILDING
BOD BOTTOM OF DUCT
BOP BOTTOM OF PIPE
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNITS PER HOUR
BYP BYPASS
CA COMBUSTION AIR
CAV CONSTANT AIR VOLUME
CFM CUBIC FEET PER MINUTE
CHW CHILLED WATER
CL CENTERLINE
CLG CEILING
CONC CONCRETE
COND CONDENSATE
COP COEFFICIENT OF PERFORMANCE
CNDW CONDENSER WATER
CPD CONDENSATE PUMP DISCHARGE
DB DRY BULB
DCW DOMESTIC COLD WATER
DDC DIRECT DIGITAL CONTROL
DEG DEGREE
DP DIFFERENTIAL PRESSURE
DX DIRECT EXPANSION
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EC ELECTRICAL CONTRACTOR
ECON ECONOMIZER
EER ENERGY EFFICIENCY RATIO
EFF EFFICIENCY
EL ELEVATION
ELEC ELECTRIC/ELECTRONIC
ENGR ENGINEER
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
EX EXISTING
EXH EXHAUST
EXP EXPANSION
FA FIELD ADJUSTABLE
FC FAIL CLOSED
FE FUME HOOD EXHAUST
FLA FULL LOAD AMPS
FLR FLOOR
FO FAIL OPEN
FOF FUEL OIL FILL
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FOV FUEL OIL VENT
FPI FINS PER INCH
FPM FEET PER MINUTE
FPS FEET PER SECOND
GA GAUGE
GAL GALLONS
GALV GALVANIZED
GC GENERAL CONTRACTOR
GE GENERAL EXHAUST
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HHW HEATING HOT WATER
HOA HAND-OFF-AUTOMATIC
HP HORSE POWER
HPC HIGH PRESSURE CONDENSATE
HPS HIGH PRESSURE STEAM
HW HOT WATER
HZ HERTZ
IA INSTRUMENT AIR
KE KITCHEN EXHAUST
KEF KITCHEN EXHAUST FAN
KW KILOWATT
LAT LEAVING AIR TEMPERATURE
LPC LOW PRESSURE CONDENSATE
LPS LOW PRESSURE STEAM
LRA LOCKED ROTOR AMPS
LWT LEAVING WATER TEMPERATURE
MBH THOUSANDS OF BTU PER HOUR
MC MECHANICAL CONTRACTOR
MCA MINIMUM CIRCUIT AMPS
MEP MECHANICAL, ELECTRICAL AND PIPING
MER MECHANICAL EQUIPMENT ROOM
MIN MINIMUM
MOCP MAXIMUM OVERCURRENT PROTECTION
NA NOT APPLICABLE
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
OA OUTSIDE AIR
OC ON CENTER
OV OUTLET VELOCITY
PC PLUMBING CONTRACTOR
PD PRESSURE DROP
PH PHASE
PP POLYPROPYLENE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH ABSOLUTE
PSIG POUNDS PER SQUARE INCH GAUGE
R RETURN
RA RETURN AIR
RH RELATIVE HUMIDITY
RPM REVOLUTIONS PER MINUTE
S SUPPLY
SA SUPPLY AIR
SCH SCHEDULE
SF SQUARE FOOT
SP STATIC PRESSURE
SS STAINLESS STEEL
TA TRANSFER AIR
TDH TOTAL DYNAMIC HEAD
TP TOTAL PRESSURE
TSP TOTAL STATIC PRESSURE
TYP TYPICAL
UC UNDERCUT
UV ULTRAVIOLET
V VOLTS
VAV VARIABLE AIR VOLUME
VP VELOCITY PRESSURE
VTR VENT THRU ROOF
WB WET BULB
WC WATER COLUMN
WG WATER GAUGE
AO ANALOG OUTPUT (CONTROLS)
AI ANALOG INPUT (CONTROLS)
DI DIGITAL INPUT (CONTROLS)
DO DIGITAL OUTPUT (CONTROLS)
EQUIPMENT ABBREVIATIONS
AAV AUTOMATIC AIR VENT
AC AIR CONDITIONING
ACC AIR COOLED CONDENSER
ACCU AIR COOLED CONDENSING UNIT
ACU AIR CONDITIONING UNIT
AHU AIR HANDLING UNIT
CC COOLING COIL
CH CHILLER
CP CONDENSATE PUMP/CONTROL PANEL
CT COOLING TOWER
CUH CABINET UNIT HEATER
CV CONVERTOR
AS AIR SEPARATOR
AT AIR TERMINAL DEVICE
B BOILER
BBS BOILER BLOWDOWN SEPARATOR
BDD BACKDRAFT DAMPER
BFP BACKFLOW PREVENTER
BFS BOILER FEEDWATER SYSTEM
BH BOOSTER HUMIDIFIER
D DAMPER
DOAS DEDICATED OUTDOOR AIR SYSTEM
EF EXHAUST FAN
EH EXHAUST HOOD
EBH ELECTRIC BASEBOARD HEATER
ERU ENERGY RECOVERY UNIT
ERV ENERGY RECOVERY VENTILATOR
ET EXPANSION TANK
EUH ELECTRIC UNIT HEATER
EV EXHAUST VALVE
EVAP EVAPORATOR
F FILTER
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FD FLOOR DRAIN
FOP FUEL OIL PUMP
FOT FUEL OIL TANK
FPB FAN POWERED BOX
FT FLASH TANK
FTR FIN TUBE RADIATION
GEN GENERATOR
H HUMIDIFIER
HC HEATING COIL
HP HEAT PUMP
HRC HEAT RECOVERY COIL
HT HEAT TRACE
HX HEAT EXCHANGER
IH INTAKE HOOD
MAU MAKEUP AIR UNIT
MCC MOTOR CONTROL CENTER
P PUMP
PHC PREHEAT COIL
PRV PRESSURE REDUCING VALVE
PTAC PACKAGED TERMINAL AIR CONDITIONER
RCP RADIANT CEILING PANEL
RF RETURN FAN
RH RELIEF HOOD
RHC REHEAT COIL
RTU ROOFTOP UNIT
SAD SOUND ATTENUATING DEVICE
SD SMOKE DETECTOR
SF SUPPLY FAN
SRV SAFETY RELIEF VALVE
ST STORAGE TANK
T TANK
UH UNIT HEATER
UV UNIT VENTILATOR
V VALVE
VAV VARIABLE AIR TERMINAL DEVICE
VFD VARIABLE FREQUENCY DRIVE
WCC WATER COOLED CONDENSER
WF WATER FILTER
DAMPERS AND ACTUATORS
MANUAL BALANCING DAMPER
CONTROL DAMPER (MOTORIZED)
M
BACKDRAFT DAMPER
BD
1 1/2 HOUR RATED FIRE DAMPER
F2
3 HOUR RATED FIRE DAMPER
F3
1 1/2 HOUR RATED FIRE/SMOKE DAMPER
FS
OPPOSED BLADE DAMPER
PARALLEL BLADE DAMPER
MANUAL ACTUATOR
MOTORIZED ACTUATOR
M
SOLENOID ACTUATOR
S
DUCT SYMBOLS
SUPPLY DIFFUSER ANNOTATION
DUCT SIZE (INCHES)
∅ INDICATES ROUND
SUPPLY AIR
DUCT (SA)
AIR QUANTITY
(CFM)
SUPPLY
DIFFUSERS (S)
EXISTING
S-1
4508"Ø SA
RETURN/EXHAUST GRILLE ANNOTATION
RETURN AIR DUCT
(RA)
DUCT SIZES
IN INCHES
AIR QUANTITY
(CFM)
RETURN
GRILLE (R)
EXISTING
R-1
25010x10 RA
EXHAUST AIR DUCT
(EA)
DUCT SIZES
IN INCHES
AIR QUANTITY
(CFM)
EXHAUST
GRILLE (E)
EXISTING
E-1
25010"Ø EA
(X)SNEW
(X)RNEW
(X)EEXISTING
DUCTWORK
SINGLE LINE
EXISTING DUCT TO BE REMOVED
DOUBLE LINE
EXISTING DUCT TO REMAIN
FLOW DIRECTION DESIGNATION
DUCT CONTINUATION BREAK
SUPPLY AIR (SA) OR
OUTDOOR AIR (OA) DUCT
EXHAUST AIR (EA) DUCT
RETURN AIR (RA), RELIEF AIR,
OR TRANSFER AIR (TA) DUCT
GENERAL SYMBOLS
EQUIPMENT TAG
KEYNOTE
POINT OF NEW CONNECTION TO EXISTING
WHEN ON DEMO SHEET: END POINT OF DEMO
DETAIL REFERENCE (TOP=DETAIL NUMBER,
BOTTOM=DRAWING NUMBER)
M-1
PLAN CONTINUATION REFERENCE
(BOTTOM=DRAWING NUMBER)
REFER
M-1
SECTION DESIGNATION (TOP=SECTION
NUMBER, BOTTOM=DRAWING NUMBER)
M-1
PIPING
SINGLE LINE
EXISTING PIPING TO BE REMOVED
DOUBLE LINE
EXISTING PIPING TO REMAIN
FLOW DIRECTION DESIGNATION
PIPE CONTINUATION BREAK
ELBOW DOWN
ELBOW UP
BOTTOM CONNECTION
TOP CONNECTION
PIPE TEE
PIPING ANNOTATION
CHILLED WATER SUPPLY/RETURNCHWS/R
CONDENSER WATER SUPPLY/RETURNCWS/R
HEATING HOT WATER SUPPLY/RETURNHWS/R
HEAT RECLAIM WATER SUPPLY/RETURNHRWS/R
LOW PRESSURE STEAM (<15 PSI)LPS
LOW PRESSURE CONDENSATELPC
HIGH PRESSURE STEAM (XX=PRESSURE)HPS (XX)
HIGH PRESSURE COND. (XX=PRESSURE)HPC (XX)
PROCESS CHILLED WATER SUPPLY/RETURNPCHWS/R
REFRIGERANT LIQUIDRL
REFRIGERANT SUCTIONRS
NATURAL GASNG
PIPING SPECIALTIES
GENERAL PIPELINE STRAINER WITHOUT DRAIN
GENERAL PIPELINE STRAINER WITH DRAIN
BASKET STRAINER
FLANGE
UNION
CAP
THERMOMETER
PRESSURE GAUGE
MANUAL AIR VENT
TEST PORT (PRESSURE/TEMP.)
PIPING VALVES
BUTTERFLY VALVE
GATE VALVE
GLOBE VALVE
BALL VALVE
BALANCING VALVE
AUTO FLOW BALANCING VALVE
CHECK VALVE
SOLENOID VALVE
S
STEAM PRESSURE REDUCING VALVE (PRV)
2-WAY CONTROL VALVE
3-WAY MIXING VALVE
3-WAY DIVERTING VALVE
DRAIN VALVE WITH CAP
GAS PRESSURE REGULATOR
GAS SHUTOFF VALVE
REDUCED PRESSURE
BACKFLOW PREVENTER (RPP)
PRESSURE RELIEF VALVE (RV)
OR SAFETY VALVE (SV)
VACUUM RELIEF/VACUUM BREAKER
GENERAL MECHANICAL NOTES
1. THE CONTRACTORS WORK SHALL CONFORM TO ALL VA
POLICIES ON CONSTRUCTION PROCEDURES AND SHALL
COMPLY WITH ALL LOCAL CODES AND VA STANDARDS.
2. COORDINATE WITH THE VA FOR ANY EQUIPMENT
REMOVED THAT NEEDS TO BE RETURNED TO THE
OWNER.
3. COORDINATE WITH VA FOR TEMPORARY SYSTEM
SHUTDOWN PER REQUIREMENTS IN THE
SPECIFICATIONS.
4. ALL DUCTWORK SHALL BE FABRICATED OF SHEET METAL
IN ACCORDANCE WITH SMACNA STANDARDS.
5. RE-INSULATE AND PATCH EXISTING DUCTWORK AS
REQUIRED AFTER INSTALLATION OF NEW DUCTWORK OR
OTHER DEMOLITION THAT DISTURBS EXISTING
DUCTWORK AND INSULATION.
6. PROVIDE LOCKING TYPE BALANCING DAMPER AT EACH
DIFFUSER, GRILLE, AND BRANCH TAKE-OFF IN ALL
SUPPLY, RETURN, AND EXHAUST DUCTWORK. LOCATE
BALANCING DAMPER AS CLOSE TO THE BRANCH
TAKEOFF AS POSSIBLE.
7. DUCT SIZE TO DIFFUSERS, REGISTERS, AND GRILLES
SHALL BE SAME AS NECK SIZE UNLESS OTHERWISE
NOTED.
8. DUCT SIZE TO AIR TERMINAL DEVICES SHALL BE SAME AS
INLET SIZE UNLESS OTHERWISE NOTED.
9. COORDINATE DIFFUSER, REGISTER, AND GRILLE
LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING
PLAN AND ALL OTHER CEILING DEVICES.
10. PROVIDE FLEXIBLE DUCTWORK FOR DIFFUSERS,
REGISTERS, AND GRILLES. FLEXIBLE DUCT SIZE SHALL BE
SAME AS NECK SIZE OF DIFFUSER OR GRILLE AND SHALL
HAVE MAXIMUM LENGTH OF 5'-0". REFER TO
SPECIFICATIONS FOR REQUIREMENTS.
11. LOCATE AIR TERMINAL DEVICES TO ALLOW ACCESS TO
AIR TERMINAL DEVICE CONTROLLERS. ACCESS
CLEARANCE IS SHOWN ON PLANS.
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
© 2020 Virtual Energy Solutions, INC.
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
-J o lie t C
B O
C P a rk in g
E x p a n s io n M
E C
H
.r v t
/6 /2
:4
:0
P M
M001
MECHANICAL SYMBOLS AND
ABBREVIATIONS
PARKING EXPANSION AT
JOLIET CBOC
10/11/2023
EPTHEP
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID 03/24/2023
ISSUED FOR BID ADDENDUM 3 10/11/2023
F
F
F
Elev. Equip.
B003
Badge
B004
Phone
B002C
Home Based Primary
Care
B002
Stair #2
S-2
Comm.
B005
Reception
B001
Women's Restroom
B006
Men's Restroom
B011
HAC
B007
Copy Room
B009
Phone
B002A
Phone
B002B
Phone
B017
Phone
B016
A.O.
B015
Clinical Nurse Manager
B014
Chief Medical Director
B013
Patient Education/Group
Room
B011
Patient
Education/Exercise
B022
Store
B012
Corridor
C0-2
Corridor
C0-3
Corridor
C0-4
Corridor
C0-1
Mech.
B018
Elec.
B019
Gen Room
B020
PAS Call Center
B024
Education Storage
B022
Nutrition Services
B021
Main Conference Room
B023
Mech.
B025
Elevator
EL-1
New North Vestibule
Elec.
B026B
Lobby
S-1
200 CFM
S-1
100 CFM
12x10 SAVAV
Dx
Ex
Gx
Hx
Jx
Kx
K'x
Lx
1x 4x 6x 9x 12x 13x 14x
Cx
Bx
Ax
3x 5x 5.8x 8x 10x6.1x
Fx
A.E
15x
15y
15z 15aa
15bb
15cc
15dd
15ee
15ff
15gg15hh
15ii
9.5x1.2x
A
1 2
B
AHU-2
EXIST.
UH
003A
Mach. Room
003A
Elevator-2
E-2-2
T
T
S-3
260 CFM8x8 SA x S
A
12x10 SA
T
S-3
250 CFM
12x8 SA
VAV
B003A
AHU-1
EXIST.
AHU-3
EXIST.
AHU-4
EXIST.
EUH
EXISTING
DEMOLITION
NEW
PHASE LEGEND
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
© 2020 Virtual Energy Solutions, INC.
N
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
-J o lie t C
B O
C P a rk in g
E x p a n s io n M
E C
H
.r v t
/6 /2
:4
:2
P M
MH100-N
BASEMENT LEVEL -
MECHANICAL VENTILATION
PLAN - NORTH
PARKING EXPANSION AT
JOLIET CBOC
10/11/2023
EPTHEP
1/8" = 1'-0"
1 BASEMENT LEVEL - MECHANICAL VENTILATION PLAN - NORTH
0 4' 8' 16'
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID 03/24/2023
ISSUED FOR BID ADDENDUM 1 04/21/2023
ISSUED FOR BID ADDENDUM 3 10/11/2023
Engineering Space
F
F
F2
Boiler Plant
Sound Booth
Control
Sound Booth
FMS
Elevator
EL-1
EXISTING STAIR
S-2
Corridor
C1-15
Rad Control
Dispensary
Storage
1116A
Diagnostic
Marco
Rad Room
Corridor
C1-13
Corridor
C1-15A
Corridor
C1-11
Toilet
Toilet
HAC
Toilet
1112E
Soiled Utility
1112A Storage
1112B
PM&R
Treatment
1112D
Eye Tech
Visual Fields
Treatment
1112C
Toilet
Toilet
1102A
Eye
Blood Draw
1114D
Eye
Blood Draw
1114C
Draw Analysis
1114E
Toilet
1114F
Blood Draw
1114B
Eye
Eye
Women Health Exam 21
Women Health Exam 20
Mobile Port Waiting
Toilet
1068A
Toilet
1031A
Pharm. D
Pharm. D
Nutritionist
Teleretinal
Cardio/Pod Shared
Office
Soiled Utility
Clean Utility
Social Worker
Shell Space
Corridor
C1-10
Podiatry Exam
Podiatry Exam
Tech Work Room
Audiology Exam
Cast Room
Podiatry Exam
Audiology Exam
Oxygen Evaluation
Pulminary Fuction
Arterial Blood Gas
Clean Utility
Soiled Utility
Control
Stor.
Corridor
C1-12
Corridor
C1-9 Corridor
Ambulance Bay
C1-36
Corridor
C1-8--
1065B
Elec. Clos.
1089A
Scale Alcove
PAS
Elec.
1114 --
1114A
Lobby
Elevator-1
E-2-1
Office
Vestibule
Dx
Ex
Gx
Hx
Jx
Kx
K'x
Lx
1x 4x 6x 9x 12x 13x 14x
Cx
Bx
Ax
3x 5x 5.8x 8x 10x6.1x
Fx
A.E
15x
15y
15z 15aa
15bb
15cc
15dd
15ee
15ff
15gg15hh
15ii
9.5x1.2x
A
1 2
B
T
T
T
T
T
T
T
T
T
T
T
T
TT
T
T
T
T
T
T
T
T
T
T
T
T
S-1
100 CFM
VAV
S-1
140 CFM
S-1
250 CFM
10x10 SA
EUH
R-1
100 CFM R-1
250 CFM
R-1
140 CFM
10x10 RA T
EXISTING
DEMOLITION
NEW
PHASE LEGEND
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
© 2020 Virtual Energy Solutions, INC.
N
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
-J o lie t C
B O
C P a rk in g
E x p a n s io n M
E C
H
.r v t
/6 /2
:4
:2
P M
MH101-N
FIRST FLOOR - MECHANICAL
VENTILATION PLAN - NORTH
PARKING EXPANSION AT
JOLIET CBOC
10/11/2023
EPBBEP
1/8" = 1'-0"
1 FIRST FLOOR - MECHANICAL VENTILATION PLAN - NORTH
0 4' 8' 16'
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID 03/24/2023
ISSUED FOR BID ADDENDUM 1 04/21/2023
ISSUED FOR BID ADDENDUM 3 10/11/2023
MECHANICAL KEYNOTES
NUMBER KEYNOTE
9 CONNECT NEW RETURN DUCT TO EXISTING RETURN
MAIN/RISER IN THE AREA. VERIFY EXACT CONNECT POINT
IN FIELD.
W1
NOTE:
1.
2.
3.
4.
ALL VANE ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS DETAILED BY
SMACNA.
WHEN W1 DOES NOT EQUAL W2, VANE SHALL BE SINGLE THICKNESS VANE TYPE
REGARDLESS OF W DIMENSION.
ALL SINGLE THICKNESS VANES SHALL HAVE A 2" RADIUS, 1 1/2"
MAXIMUM SPACE BETWEEN VANES AND A 3/4" TRAILING EDGE.
WHEN W EQUALS W2 AND W1 IS GREATER THAN 20" VANES SHALL BE
DOUBLE VANE TYPE.
DUCTWORK SQUARE VANE ELBOWS
N.T.S.
VANE
VANE
W
R 2/3W
W
W W
1/2W
W
1/6W
NOTE:
1.
2.
THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND.
ALL STANDARD RADIUS ELBOWS CAN BE SUBSTITUTED WITH SHORT RADIUS
ELBOWS. ALL SHORT RADIUS ELBOWS SHALL HAVE VANES. VANES SHALL BE
CONSTRUCTED, SUPPORTED AND FASTENED AS RECOMMENDED BY SMACNA.
R SHALL
EQUAL
OR BE
GREATER
THAN W.
R SHALL
EQUAL
OR BE
GREATER
THAN
1/3W.
R
R SHALL
EQUAL
OR BE
GREATER
THAN
1/6W.
STANDARD RADIUS OR
LONG RADIUS ELBOW
SHORT RADIUS ELBOW
WITH ONE VANE
SHORT RADIUS ELBOW
WITH TWO VANES
R
DUCTWORK RADIUS ELBOWS
N.T.S.
W
DESIGNER'S NOTES:
1. THE SUPPLY REGISTER TAKE-OFF MAY BE USED FOR UP UP TO 25% OF THE MAIN
DUCT CFM. THE BRANCH DUCT TAKE-OFF MAY BE USED FOR UP TO 15% OF THE
MAIN DUCT CFM ANYTIME AND UP TO 40% WHEN THE MAIN DUCT VELOCITY IS 1000
FPM OR LESS. THE AIR SPLIT DUCT TAKE-OFF SHALL BE USED IN ALL
OTHER CASES AND MAY BE USED AT ANYTIME.
2. SHOW ALL VOLUME DAMPERS ON FLOOR PLANS.
AIR SPLIT DUCT TAKE-OFF
PLAN VIEW
BRANCH DUCT TAKE-OFF PLAN VIEW
SUPPLY REGISTER TAKE-OFF
PLAN VIEW
AIR
FLOW
AIR
FLOW
A
IR
F L
O W
SUPPLY REGISTER
OR BRANCH DUCT
TURNING VANES
MAIN
SUPPLY
DUCT
SEE FLOOR PLAN FOR
SPLIT DIMENSION
PROVIDE VOLUME
DAMPER
PROVIDE VOLUME
DAMPER
ADJUSTABLE
METAL ROD
OR LINKAGE
TOP REGISTER
MAIN
SUPPLY
DUCT
VOLUME EXTRACTOR; ADJUSTABLE
FROM FULLY CLOSED POSITION TO
CFM NOTED ON FLOOR PLANS
AIR
FLOW
AIR
FLOW
1/4 W OR 4"
MIN.
AIR
FLOW
MAIN SUPPLY
DUCT
A
IR
F L
O W
SUPPLY DUCTWORK TAKE-OFFS
N.T.S.
MAIN EXHAUST OR RETURN
PLAN VIEW
W
AIR
FLOW AIR
FLOW
PROVIDE VOLUME DAMPER
AT EACH BRANCH DUCT
1/4W OR 4"
MIN.
BRANCH DUCT
VD
EXHAUST OR RETURN BRANCH DUCTWORK
N.T.S.
NOTE:
1.
2.
DELETE INSULATION STAND-OFF ON DUCTWORK WITHOUT EXTERIOR INSULATION.
DETAIL SHOWS SINGLE BLADE DAMPER. DAMPER INSTALLATION SHALL BE SIMILAR
FOR MULTI-BLADE DAMPERS & ROUND DAMPERS.
INSULATION SEE
SPECIFICATION
DAMPER BLADE
1/8"
CLEARANCE
ALL AROUND
OUTSIDE END BEARING
INSIDE END BEARING
HANDLE WITH
LOCKING
QUADRANT
INSULATION
STAND-OFF
1/2"
ROUND ROD PIN
DUCT
STIFFEN BLADE
AS REQUIRED
SIDE ELEVATION SECTION
VOLUME DAMPER DETAIL
N.T.S.
SECTION "A-A"
"B" "B"
NOTES:
1. LATCHES SHALL BE OF THE WEDGE TYPE TO CLOSE DOORS
TIGHTLY.
2. HINGES ON THE ACCESS DOORS SHALL HAVE NON-CORROSIVE
PINS.
3. SEE SMACNA 2005, FIGURE 9-15
ACCESS PANEL
ACCESS DOOR
CASING
GASKET
HANDLE INSIDE
FLEXIBLE
WASHER
FACTORY
FABRICATED
LATCH
SECTION "B-B"
INSULATION
DUCT
GASKET
INSULATION
INSULATION
"A"
"A"
ACCESS PANEL AND DOOR DETAIL
N.T.S.
ROUND FLEXIBLE CONNECTION
RECTANGULAR FLEXIBLE CONNECTION
1/2" 1/2"
1/2"
FLANGED CONNECTION
ON FAN SIDE
WASHER 1-1/2" MIN. TO 3"
MAX. INSTALLED. 6"
NOMINAL WITH MATERIAL TAUT
FLEXIBLE
MATERIAL AS
SPECIFIED
1"x1/8" DRAW BAND
1"x1/8" BAND IRON
BOLT ON 4" CENTERS
5/16" FLANGE
DUCT
SHEET METAL SCREWS ON
12" CENTERS
RIVET ON 4"
CENTERS
SHEET METAL AS
SPECIFIED FOR
DUCTWORK.
1"x1/8" BAND IRON
BOLT ON 4" CENTERS
1" FLANGE & HEMALTERNATE
POSITION
OF BOLT 1 1/2"
POCKET SLIP
DUCT
SHEET METAL AS
SPECIFIED FOR
DUCTWORK.
1 1/2" MIN. TO 3"
MAX. INSTALLED. 6"
NOMINAL WITH MATERIAL TAUT
FLANGED
CONNECTION
ON FAN SIDE
WASHER
FLEXIBLE MATERIAL
AS SPECIFIED
FLEXIBLE DUCT CONNECTIONS AT EQUIPMENT
N.T.S.
420ONE 1 x 18 GA STRAP36
TWO 1/2∅ RODS
TWO 3/8∅. RODS
ONE 1 x 16 GA STRAP
50 700
ONE 1 x 22 GA STRAP
QUANTITY/SIZEMAX. DUCT ∅
HANGER STRAPS OR RODS
MAX. LOAD
LBS.
MAX.
IN.
SPACING
IN. IN.
NOTE:
TABULATED DATA FROM SMACNA
ALLOWS FOR DUCT REINFORCING AND
INSULATION, BUT NO EXTERNAL LOAD.
BAND
OVER 50"∅
HANGER RODS
BAND OF SAME
SIZE AS HANGER
STRAP
LOAD RATED
FASTENERS
50"∅
& UNDER
ROUND DUCT HANGERS
N.T.S.
NOTE:
ALL DUCT WORK RISERS WHICH ARE RUN EXPOSED, SUCH AS THRU ATTIC FLOORS
AND FAN ROOM FLOORS SHALL BE PROVIDED WITH A 3" HIGH CONCRETE
CURB AROUND OPENING FOR DUCT.
SEAL HOLE WITH FIREPROOFING
MATERIAL AFTER DUCT INSTALLATION
2"x2"x1/4" ANGLE INSTALL
ON BOTH LONG
DIMENSION SIDES OF DUCT.
DUCT RISER - SEE FLOOR
PLANS FOR DETAILS
SEAL HOLE WITH FIREPROOFING
MATERIAL AFTER DUCT INSTALLATION
FLOOR
EXTEND ANGLE 3"
BEYOND DUCT
DUCT RISER - SEE FLOOR
PLANS FOR SIZES SHEET METAL SCREWS 4"
ON CENTER
1 1/2"x1 1/2"x1/8"
ANGLE INSTALL ON BOTH LONG
DIMENSION SIDES OF DUCT. FOR
DUCTS OVER 60" USE
2"x2"x1/8" ANGLE.
HOLE IN STRUCTURAL FLOOR
DUCT RISER
0.5 INCH WG TO 2 INCHES WG DUCT RISER SUPPORT
ARRANGE RISER SO
REINFORCER TRANSVERSE JOINT
IS AT RISER SUPPORT POINT
FLOOR
2 INCHES WG TO 4 INCHES WG DUCT RISER SUPPORT
HOLE IN STRUCTURAL FLOOR
DUCT RISER
DUCT RISER SUPPORTS
N.T.S.
BRANCH DUCT INSULATED FLEXIBLE AIR DUCT
CONNECTOR LENGTH NOT TO
EXCEED 3'
VOLUME
DAMPER
ROUND OR OVAL
INLET COLLAR
MINIMUM 2"
EXTENSION
INACTIVE LENGTHS
TYP.
PLENUM WITH
INTERNALLY LINED
INSULATION
NOTES:
1.COORDINATE SLOT DIFFUSER FRAME/BORDER
TYPE AND END BORDER CONFIGURATION WITH
CEILING TYPE.
INSULATED PLENUM
INLET COLLAR
LINEAR
DIFFUSER
CEILING
ACTIVE LENGTH
SUPPLY DUCT
LINEAR SLOT DIFFUSER
N.T.S.
DUCT
SEAL OPENING WITH FIRE
STOPPING SEAL FOR RATED
WALL SEE NOTE 2).
DUCT INSULATION
NOTES:
1. DUCT PENETRATION THROUGH NON-RATED OR 1 HR FIRE RATED WALL.
2. IF WALL IS FIRE RATED, SEALANT AND INSULATION SHALL CONFORM
TO THE ASSOCIATED FIRE RATING.
DUCT PENETRATION THROUGH INTERIOR WALL
N.T.S.
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
© 2020 Virtual Energy Solutions, INC.
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
-J o lie t C
B O
C P a rk in g
E x p a n s io n M
E C
H
.r v t
/6 /2
:4
:0
P M
M501
MECHANICAL DETAILS
PARKING EXPANSION AT
JOLIET CBOC
10/11/2023
EPTHEP
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
S E E
N O T E
SEE NOTE
SEE NOTE
SEE NOTE
NOTE:
1.
2.
3.
4.
5.
RIGID STRAIGHT TERMINAL UNIT INLET LENGTH SHALL BE A
MINIMUM OF 3 TIMES THE DIAMETER OF INLET
A FLEXIBLE AIR DUCT CONNECTOR IS NOT MANDATORY FOR INLET TO
THIS BOX, BUT ALLOWED TO ACCOMMODATE MINOR OFFSETS. MAXIMUM
LENGTH 3'-0".
A BRANCH DUCT SERVING AN INDIVIDUAL BOX MAY BE THE SAME SIZE
AS THE BOX INLET, PROVIDED THE EQUIVALENT LENGTH OF THE
BRANCH DUCT, AS SHOWN, DOES NOT EXCEED 10 FEET.
FOR LONGER LENGTHS, INCREASE THE DUCT SIZE AND PROVIDE A
DUCT TRANSITION TO MAINTAIN THE DUCT STATIC PRESSURE DROP AT
OR BELOW 0.2"/100'.
FLEXIBLE AIR DUCT CONNECTORS, WHEN USED FROM TERMINAL UNIT
SUPPLY AIR DUCT TO DIFFUSER, SHALL NOT EXCEED 5'-0".
USE RIGID ELBOWS FOR CHANGE OF DIRECTION GREATER
THAN 45°.
COMPONENT ARRANGEMENT MAY VARY BY MANUFACTURER. PROVIDE
INSULATION W/VAPOR BARRIER FOR CONNECTING DUCT SECTIONS.
AIR TERMINAL UNIT
(CV OR VAV)
REHEAT COIL
SOUND ATTENUATOR (IF SPECIFIED)
SEE EQUIPMENT SCHEDULE
FLEXIBLE AIR DUCT
CONNECTOR. SEE DETAIL
DIFFUSER (TYP.)
SEE SPECIFICATIONS FOR
CLAMPS AND SEALANT (TYP.)
SEE NOTE 5
DUCT CONNECTIONS - AIR TERMINAL UNITS
N.T.S.
DRAW BAND ON OUTER LINER. SEE NOTE 2
DRAW BAND ON INNER LINER. SEE NOTE 1
FLEXIBLE DUCT
(5' MAX LENGTH)
FSK TAPE BETWEEN
FLEX DUCT AND
RIGID DUCT INSULATION
DUCT INSULATION
ROUND DUCT
NOTES:
1. MINIMUM 4" OVERLAP.
SECURE WITH STAINLESS
STEEL DRAW BAND.
2. METAL OR PLASTIC DRAW
BAND.
FLEX. DUCT CONNECTION TO INSULATED ROUND DUCT
N.T.S.
FROM STRUCTURE
SAME AS DIFFUSER
INLET: 5'-0" MAX
FLEXIBLE DUCT SIZE
LENGTH.
12"
CEILING
SUPPORT SADDLE
VOLUME DAMPER W/
LOCKING QUADSADDLE
SHEET METAL
CONICAL OUTLET
BRANCH DUCT
FOR CHANGE OF
DIRECTION GREATER
USE RIGID ELBOWS
THAN 45°
SEE SPECIFICATIONS FOR CLAMPS
AND SEALANT (TYP.)
NOTE:
THE USE OF FLEXIBLE AIR DUCT CONNECTORS ARE NOT PERMITTED
FOR THE DEDICATED AHU SERVING THE SURGICAL SUITE.
TYPICAL
DIFFUSER OR
REGISTER IN
LAY-IN CLG.
THERMAL INSULATION
SEE SPECIFICATIONS
FLEXIBLE AIR DUCT CONNECTOR
N.T.S.
NOTE:
1.
2.
3.
4.
5.
6.
A VERTICAL DAMPER IS SHOWN. HORIZONTAL DAMPER INSTALLATION, 1S SIMILAR.
FOLLOW DAMPER MANUFACTURER'S INSTRUCTIONS, INCLUDING FASTENER OPTIONS AND
GAGES FOR SLEEVE AND PERIMETER ANGLES. FIRE DAMPERS MUST BE INSTALLED IN
THE PARTITION OR FLOOR AND NOT OUTSIDE THE PENETRATION.
GALVANIZED SLEEVE: GAGE NOT LESS THAN CONNECTING DUCT. FASTEN SLEEVE TO
DAMPER FRAME AND TO PERIMETER ANGLES.
PERIMETER ANGELS: GALVANIZED STEEL, NOT LESS THAN 1 1/2"x1 1/2", 14 GAGE, TO PROVIDE 1" MINIMUM OVERLAP OF OPENING ON ALL 4 SIDES.
BREAKAWAY DUCT CONNECTION: CONTRACTOR'S OPTION OF TYPES SHOWN IN SMACNA.
ACCESS PANELS: SIZE AND LOCATION TO PERMIT SERVICING THE FUSIBLE LINK OR
LINKS.
PROVIDE 1/4" TO 1/2" CLEARANCE ON HEIGHT AND WIDTH. FILL OPEN
SPACE WITH ROCK WOOL FIRESTOP FIBER.
ALL DUCT WORK RISERS WHICH ARE RUN EXPOSED, SUCH AS THRU ATTIC FLOORS
AND MECHANICAL ROOM FLOORS, SHALL BE PROVIDED WITH 3" HIGH
CONCRETE CURB AROUND OPENING FOR DUCT.
SLEEVE, NOTE 2
DUCT
CONNECTION
NOTE 4
DAMPER,
NOTE 1
DAMPER COLLAR
EXTENSION INTEGRAL
PART OF SLEEVE
SLEEVE, NOTE 2
NOTE 6FIRE BARRIER
PARTITION OR CHASE
TYPICAL DUCT
INSULATION
PERIMETER ANGLE, NOTE 3
(NOTE FASTENED TO PARTITION)
ACCESS
PANEL
NOTE 5
SECTION THRU FIRE DAMPER INSTALLATION
N.T.S.
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
© 2020 Virtual Energy Solutions, INC.
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
-J o lie t C
B O
C P a rk in g
E x p a n s io n M
E C
H
.r v t
/6 /2
:4
:1
P M
M502
MECHANICAL DETAILS
PARKING EXPANSION AT
JOLIET CBOC
10/11/2023
EPTHEP
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
© 2020 Virtual Energy Solutions, INC.
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
-J o lie t C
B O
C P a rk in g
E x p a n s io n M
E C
H
.r v t
/6 /2
:4
:1
P M
M601
MECHANICAL SCHEDULES
PARKING EXPANSION AT
JOLIET CBOC
10/11/2023
EPTHEP
UNIT HEATER SCHEDULE (ELEC)
TAG LOCATION HTG. ELEMENT DATA FAN MOTOR DATA UNIT ELECTRICAL DATA DIMENSIONS (IN) UNIT
WEIGHT
(LBS)
BASIS OF DESIGN
REMARKS
TYPE MARK
ROOM
NUMBER
ROOM NAME
CAPACITY
(KW)
L.A.T.
(DEG. F)
FAN AIRFLOW
(CFM)
QTY FLA V PH HZ L W H MANUFACTURER MODEL
UH 003A 003A Mach. Room 3 105 350 1 15 480 3 60 21 5 19 24 MARLEY MUH0381 REMOTE THERMOSTAT
CABINET UNIT HEATER SCHEDULE (ELEC)
TAG LOCATION HTG. ELEMENT DATA FAN MOTOR DATA UNIT ELECTRICAL DATA
DIMENSIONS
LxWxH
BASIS OF DESIGN
REMARKS
TYPE MARK
ROOM
NUMBER
ROOM NAME KW L.A.T. (DEG. F) CFM QTY FLA V PH HZ L W H MANUFACTURER MODEL
EUH 001 001 New North Vestibule 20 123 1000 2 26 480 3 60 85 25 10 MARLEY CU978 PROVIDE WITH REMOTE THERMOSTAT
EUH 104 104 Vestibule 6 98 500 1 8 480 3 60 45 10 26 MARLEY CU945
DIFFUSER/ REGISTER/ GRILLE SCHEDULE
TAG SYSTEM DESCRIPTION
FACE SIZE
(IN.) NECK SIZES CFM RANGE
MOUNITNG TYPE DAMPER
MATERIAL /
FINISH MAX. N.C. REMARKSW L
NECK
DIAMETER
NECK
WIDTH
NECK
LENGTH MIN. MAX
R-1 Return Air SQUARE PERFORATED 24 24 6 0 135 LAY-IN No WHITE STEEL 30
R-1 Return Air SQUARE PERFORATED 24 24 8 136 245 LAY-IN No WHITE STEEL 30
R-1 Return Air SQUARE PERFORATED 24 24 10 246 380 LAY-IN No WHITE STEEL 30
S-1 Supply Air SQUARE PLAQUE 24 24 6 0 100 LAY-IN No WHITE STEEL 30
S-1 Supply Air SQUARE PLAQUE 24 24 8 101 250 LAY-IN No WHITE STEEL 30
S-3 Supply Air LOUVERED 10 10 8 8 0 300 SURFACE MOUNT No WHITE STEEL 30
VAV SCHEDULE
TAG COOLING CFM
INLET SIZE
MIN. INLET S.P.
INCH W.C.
SOUND
ATTENUATOR
(Y/N)
MAX N.C. BASIS OF DESIGN
REMARKSTYPE MARK MAX MIN DISCHARGE RADIATED MANUFACTURER MODEL
VAV 002 560 187 8 0.50 No 30 30 NAILOR D3001
VAV B003A 250 83 6 0.50 No 30 30 NAILOR D3001
VAV SCHEDULE (ELEC REHEAT)
TAG COOLING CFM HEATING CFM
INLET SIZE
MIN. INLET S.P.
INCH W.C.
HEATING COIL DATA SOUND
ATTENUATOR
(Y/N) REMARKSTYPE MARK MAX MIN MAX MIN TOTAL MBH KW V PH HZ EAT DWG. F LAT DEG. F
VAV 103 490 50 490 50 6 0.50 20478.0 6 480 3 60 55 95 No
VAV: 1
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ABBREVIATIONS
ABOVE COUNTER
ABOVE FINISHED FLOOR
AUTOMATIC TRANSFER SWITCH
BOLTED PRESSURE SWITCH
BLOWN FUSE PROTECTION
CIRCUIT BREAKER
CIRCUIT
CONDUIT ONLY
DISCONNECT
DOWN
DOUBLE POLE DOUBLE THROW
EXISTING TO REMAIN
EMERGENCY
EMERGENCY POWER OFF
ELECTRIC WATER COOLER
FIRE ALARM
FAN COIL UNIT
FAN POWERED BOX
FORCED FLOW CONVECTOR
GROUND FAULT INTERRUPTER
GROUND
HIGH INTENSITY DISCHARGE
HAND OFF AUTOMATIC
HORSEPOWER
JUNCTION BOX
ISOLATED GROUND
KILOVOLT
KILOWATT
LIGHTING
MAIN CIRCUIT BREAKER
MAIN LUGS ONLY
MEDIUM VOLTAGE
NORMALLY CLOSED (CONTACTS)
NOT IN CONTRACT
NORMALLY OPEN (CONTACTS)
NOT TO SCALE
PANEL
PRIMARY
POTENTIAL TRANSFORMER
REFLECTED CEILING PLAN
SECONDARY
SINGLE POLE DOUBLE THROW
SWITCH
TELEPHONE
TAMPER PROOF
UNIT HEATER
VAPOR PROOF
WEATHERPROOF
WATERTIGHT
EXPLOSION PROOF
AC
AFF
ATS
BPS
BFP
CB
CCT
CO
DISC
DN
DPDT
EX
EM
EPO
EWC
FA
FCU
FPB
FFC
GFI
GRD
HID
HDA
HP
JB
IG
KV
KW
LTG
MCB
MLO
MV
NC
NIC
NO
NTS
PNL
PRI
PT
RCP
SEC
SPDT
SW
T
TP
UH
VP
WP
WT
XP
EXISTING RELOCATEDEXR
CONDUIT
CONDUIT RUN CONCEALED IN CEILING OR WALL.
ARROWHEAD DENOTES HOMERUN TO
PANELBOARD
SLASH LINES INDICATE QUANTITY OF WIRE.
GROUND WIRE INDICATED AS LONG LINE WITH
DOT, NEUTRAL INDICATED AS LONG LINE AND
PHASE CONDUCTORS INDICATED AS SHORT LINES.
CONDUIT RUN CONCEALED IN SLAB OR BELOW
SLAB. DITTO FOR ARROW AND NUMBER OF WIRES
INDICATED
CONDUIT RUN EXPOSED. DITTO FOR ARROW AND
NUMBER OF WIRES INDICATED
CONDUIT RUN STUBBED UP
CONDUIT RUN STUBBED DOWN
FLEXIBLE CONDUIT CONNECTION
CONDUIT TERMINATION, STUB OUT.
STAIRS
EXIT
FIRE ESCAPE
EXIT
FIRE ESCAPE
STAIRS
STAIRS
EXIT
FIRE ESCAPE
EXIT
BATTERY PACK FIXTURES WITH
NUMBER OF HEADS SHOWN
24 EXIT
STAIRS
FIRE ESCAPE
EXIT
STAIRS
FIRE ESCAPE
EXIT
FIRE ESCAPE
STAIRS
ELEVATOR
SYMBOL
CHICAGO
CODE No.
STAIRS
DESCRIPTION
FIRE ESCAPE
SINGLE FACE
SYMBOL
CHICAGO
CODE No.
DESCRIPTION
TRIANGLE
FLUSH OR
RECESSED
DOUBLE FACE
EXIT SIGN SCHEDULE
MAGNETIC MOTOR STARTER
COMBINATION MOTOR STARTER
EQUIPMENT IDENTIFICATION
DISCONNECT SWITCH, RATING AS INDICATED
FUSIBLE DISCONNECT, RATING AS INDICATED
SINGLE POLE MANUAL STARTER WITH THERMAL
OVERLOAD PROTECTION FOR FRACTIONAL SINGLE
PHASE MOTORS. 'P' INDICATES PILOT LIGHT AND
'2T' INDICATES DOUBLE POLE
P
2T
MOTORS AND CONTROLS
MOTOR, REFER TO SCHEDULE FOR HORSEPOWER,
DESCRIPTION, WIRING AND PANEL FED FROM1
M
MOTOR, NUMBER INDICATES HORSEPOWER5
CABLE TERMINATION
POT HEAD
SINGLE THROW SWITCH
MOLDED CASE CIRCUIT BREAKER (NUMBER
INDICATES POLES)2
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER
TRANSFORMER
ONE-LINE ELECTRICAL DIAGRAM SYMBOL
GROUND
INCOMING LINE
UM UTILITY METER
JUNCTION BOX
RACEWAYS AND WIREWAYS
JUNCTION BOX - WALL MOUNTED
JUNCTION BOX WITH FLEXIBLE CONNECTIONJ
J
J
JUNCTION BOX FOR FURNITURE POWER IN-FEEDSP
JUNCTION BOX FOR TELE/DATA IN-FEEDSC
SINGLE GANG JUNCTION BOX WITH 1"C TO
TECHNOLOGY CLOSET.
PROVIDE DUAL CHANNEL LEGRAND 25DTP SERIES
POWER POLE FOR POWER AND LOW VOLTAGE
CABLING. SUPPORT RACEWAY AT BOTH ENDS.
NOTES:
"F1" DENOTES FIXTURE TYPE, REFER TO LIGHTING FIXTURE
SCHEDULE FOR DESCRIPTION AND MOUNTING. THE CIRCUIT
NUMBER "EM1" DENOTES LIGHT FIXTURE WIRED TO LIFE SAFETY
SYSTEM.
LIFE SAFETY LUMINARIES
F1
EM1
LIGHTING FIXTURE WIRED TO LIFE
SAFETY SYSTEM
FLUORESCENT STRIP LIGHT
WIRED TO LIFE SAFETY SYSTEM
2x4 FLUORESCENT LIGHTING
FIXTURE WIRED TO LIFE SAFETY
SYSTEM
1x4 FLUORESCENT LIGHTING
FIXTURE WIRED TO LIFE SAFETY
SYSTEM
DUPLEX RECEPTACLE - POKE-THROUGH FITTING
INCLUDING DRILLING ALL OTHER COMPONENTS.
WIREMOLD 880CS3-1, 3-GANG W/ (2) DUPLEX
RECEPTACLES AND 1 GANG FOR LOW VOLTAGE
CABLING.
A
WIREMOLD RFB4 4-GANG W/ (2) DUPLEX
RECEPTACLES AND (2) GANGS FOR LOW VOLTAGE
CABLING.
B
FL
CTR
CONTROL PANEL CIRCUIT. PROVIDE DEDICATED
CIRCUIT CONNECT TO MECHANICAL OR PLUMBING
CONTROL PANEL. VERIFY LOCATION IN FIELD.
HL
S
INTERCOM SPEAKER. DISCONNECT AND STORE
FOR RE-INSTALL AT THE END OF CONSTRUCTION.
EXTEND CABLING AND CONDUIT AS REQUIRED.
50% SWITCHED RECEPTACLE
DUPLEX
DUPLEX
DOUBLE
ABOVE COUNTER RECEPTACLE
USB RECEPTACLE
TAMPER PROOF RECEPTACLE
GFI RECEPTACLE
CRITICAL RECEPTACLE
SPECIAL RECEPTACLE - REFER TO PLANS FOR
NEMA TYPE
FIXED EQUIPMENT CONNECTION
STANDARD RECEPTACLE
CEILING MOUNTED RECEPTACLES (W / CIRCLE)
FLOOR MOUNTED RECEPTACLES (W / SQUARE)
WALL MOUNTED RECEPTACLES (W / STEM)
INSTALL LEVEL WITH FINISHED CEILING.
ABOVE COUNTER GFI RECEPTACLE
JUNCTION BOXES FOR ELECTRIC LAVATORIES
SENSORS. CONTRACTOR TO PROVIDE CIRCUIT
SHOWN AND ALL ASSOCIATED CONDUIT AND
WIRING FOR A COMPLETE OPERATING SYSTEM.
TYPICAL FOR EVERY LAVATORY, URINAL AND
TOILET FLUSH LOCATION. MULTIPLE LAVATORIES
AT TOILETS REQUIRED A SINGLE CONNECTION.
PROVIDE TRANSFORMERS ABOVE CEILING W/
ACCESS PANELS AND PROVIDE GFI CKT BREAKER
AT CORRESPONDING BREAKER.
JUNCTION BOXES FOR FLUSH SENSORS.
CONTRACTOR TO PROVIDE CIRCUIT SHOWN AND
ALL ASSOCIATED CONDUIT AND WIRING FOR A
COMPLETE AND OPERATING SYSTEM.
TYPICAL FOR EVERY LAVATORY, URINAL AND
TOILET FLUSH LOCATION. MULTIPLE LAVATORIES
AT TOILETS REQUIRED A SINGLE CONNECTION.
PROVIDE TRANSFORMERS ABOVE CEILING W/
ACCESS PANELS AND PROVIDE GFI CKT BREAKER
AT CORRESPONDING BREAKER.
MOUNTING HEIGHT 1'-6"
SUPPORT TO STRUCTURE.
ELECTRICAL HAND DRYER. PROVIDE DEDICATEDH
CIRCUIT.
WEATHERPROOF, GFI RECEPTACLE
RECEPTACLES
TAMPER SWITCH
WATER FLOW DETECTOR
DUCT SMOKE DETECTOR
AUDIBLE ALARM DEVICE
SMOKE DETECTOR
PULL STATION
RELAY MODULE
HEAT DETECTOR
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR PANEL
ANSUL PANEL
REMOTE TEST SWITCH AND ANNUNCIATOR
REMOTE ANNUNCIATOR
VISUAL ALARM DEVICE
FIREMAN'S 2-WAY COMM PHONE
SPEAKER / VISUAL ALARM DEVICE
SPEAKER
DOOR HOLD OPEN
KNOCKBOX
ANSUL
FAAP
FACP
HD
FIRE ALARM SYMBOLS
CEILING MOUNTED DEVICES (W / CIRCLE)
WALL MOUNTED DEVICES (W / STEM)
H
SD
DD
SD
SD
MM
RTS
TS
WF
S
A
T
RA
SV
S
V
K
171'-250' IN LENGTH: 6#8,1#8G,1"C
101'-170' IN LENGTH: 6#10,1#10G,3/4"C
0'-100' IN LENGTH: 6#12,1#12G,3/4"C
C) THREE (3) BRANCH CIRCUITS PER HOMERUN-
171'-250' IN LENGTH: 4#8,1#8G,3/4"C
101'-170' IN LENGTH: 4#10,1#10G,3/4"C
0'-100' IN LENGTH: 4#12,1#12G,3/4"C
B) TWO (2) BRANCH CIRCUITS PER HOMERUN-
CONNECTED TO 208Y/120 VOLT SYSTEMS SHALL BE, U.N.O.:
BRANCH CIRCUIT WIRING FOR 20 AMP, 120 VOLT CIRCUITS
BRANCH CIRCUITS SHALL BE CONNECTED TO 20A,1P CB'S, U.N.O.1.
2.
171'-250' IN LENGTH: 2#8,1#8G,3/4"C
101'-170' IN LENGTH: 2#10,1#10G,3/4"C
0'-100' IN LENGTH: 2#12,1#12G,3/4"C
A) ONE (1) BRANCH CIRCUIT PER HOMERUN-
PROVIDE A DEDICATED NEUTRAL WITH EACH BRANCH CIRCUIT.4.
PROVIDE AN INSULATED GROUND WIRE WITH EACH CIRCUIT.5.
351'-550' IN LENGTH: 6#8,1#8G,1"C
201'-350' IN LENGTH: 6#10,1#10G,3/4"C
0'-200' IN LENGTH: 6#12,1#12G,3/4"C
C) THREE (3) BRANCH CIRCUITS PER HOMERUN-
351'-550' IN LENGTH: 4#8,1#8G,3/4"C
201'-350' IN LENGTH: 4#10,1#10G,3/4"C
0'-200' IN LENGTH: 4#12,1#12G,3/4"C
B) TWO (2) BRANCH CIRCUITS PER HOMERUN-
CONNECTED TO 480Y/277 VOLT SYSTEMS SHALL BE, U.N.O.:
BRANCH CIRCUIT WIRING FOR 20 AMP, 277 VOLT CIRCUITS3.
351'-550' IN LENGTH: 2#8,1#8G,3/4"C
201'-350' IN LENGTH: 2#10,1#10G,3/4"C
0'-200' IN LENGTH: 2#12,1#12G,3/4"C
A) ONE (1) BRANCH CIRCUIT PER HOMERUN-
GENERAL BRANCH CIRCUIT NOTES
1. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS OF
HVAC, PLUMBING AND FIRE PROTECTION EQUIPMENT.
2. CAREFULLY REVIEW THE ARCHITECTURAL, STRUCTURAL,
MECHANICAL, HVAC AND PLUMBING PLANS AND
SPECIFICATIONS FOR FURTHER WORK SCOPE AND FOR
ADDITIONAL INFORMATION.
3. PROVIDE RACEWAY AND 120V POWER FOR SECURITY
SYSTEM DEVICES. COORDINATE WORK WITH SECURITY
CONTRACTOR, PRIOR TO INSTALLATION.
4. PROVIDE RACEWAY, 120V POWER AND GROUNDING FOR
COMMUNICATIONS SYSTEMS INCLUDING TELEPHONE,
DATA, CABLE TELEVISION, INTERCOM, AUDIOVISUAL, ETC.
COORDINATE WORK WITH TELECOMMUNICATIONS
CONTRACTOR, PRIOR TO INSTALLATION.
5. THE CONTRACTOR SHALL PROVIDE OVERSIZED PULL
BOXES UTILIZED FOR TELECOMMUNICATIONS, SECURITY
AND A/V WIRING AT CEILING MOUNTED ACCESS PANEL
LOCATIONS. ACCESS PANEL LOCATIONS SHALL BE
COORDINATED WITH ARCHITECT AND GENERAL
CONTRACTOR, PRIOR TO INSTALLATION.
6. FEEDER AND BRANCH CIRCUIT WIRING SHALL BE SIZED
FOR A MAXIMUM 5% VOLTAGE DROP TOTAL. UPSIZE
FEEDER AND BRANCH CIRCUIT WIRING AS REQUIRED FOR
RUN LENGTH IN THE FIELD.
7. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN A
COMPLETE AND SEPARATE RACEWAY SYSTEM AND THE
RACEWAY SHALL BE RED IN COLOR.
8. THESE DRAWINGS ARE DIAGRAMMATICAL IN NATURE,
AND INDICATE THE GENERAL ARRANGEMENT OF
EQUIPMENT, BUT ACCURACY IS NOT GUARANTEED. FIELD
VERIFICATION OF LOCATIONS AND DIMENSIONS MAY BE
REQUIRED.
9. THESE DRAWINGS WILL NOT SHOW ALL INSTALLATION
DETAILS. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO MAKE A COMPLETE AND SATISFACTORY
INSTALLATION IN ACCORDANCE WITH NECA 1 AND
MODERN PRACTICE METHODS.
10. EQUIPMENT DIMENSIONS SHOWN ON PLANS AND
ELEVATIONS ARE APPROXIMATE ONLY. THE CONTRACTOR
SHALL USE THE SHOP DRAWINGS FOR PROPER LAYOUT,
FOR FINAL INSTALLATION, WITHOUT ANY ADDITIONAL
COST TO THE OWNER.
11. ELECTRICAL CONTRACTOR SHALL MAKE THEIR OWN
COUNT OF ALL EQUIPMENT TO BE WIRED BASED ON
PLANS AND SPECIFICATIONS.
12. PROVIDE ARC FLASH WARNING LABELS ON ALL NEW
PANELBOARDS AS DESCRIBED IN 2014 NEC 110.16.
13. ALL NEW CIRCUITS SHALL BE RUN WITH DEDICATED
NEUTRALS PER 2014 NEC 200.4. SHARED NEUTRALS ARE
NOT ALLOWED.
14. PROVIDE AN INSULATED GROUND WIRE WITH ALL
CIRCUITS.
15. LABEL EACH RECEPTACLE WITH THE PANEL NAME AND
CIRCUIT NUMBER SERVING THEM.
16. ALL NEW RECEPTACLES CONNECTED TO CRITICAL
POWER SHALL HAVE RED BODIES AND COVER PLATES.
17. ALL NEW SWITCHES CONNECTED TO CRITICAL POWER
SHALL HAVE RED HANDLES.
18. ALL RECEPTACLES IN PATIENT CARE AREAS SHALL BE
BOTH TAMPER RESISTANT AND HOSPITAL GRADE TYPES.
19. THE ELECTRICAL CONTRACTOR SHALL SUBMIT AND
RECEIVE REVIEWED SHORT CIRCUIT AND SELECTIVE
COORDINATION STUDIES, PRIOR TO SUBMITTING
SWITCHBOARD, PANELBOARD AND OVERCURRENT
DEVICES FOR REVIEW.
20. LIGHTING SHALL BE 277 VOLTS, EXCEPT WITHIN PATIENT
ROOMS, PATIENT BATHROOMS, SECLUSION ROOMS, ANTE
ROOMS, AND THE ELEVATOR PIT WHERE THE LIGHTING
SEE SPECIFICATIONS.
21. RECEPTACLES AND LIGHT SWITCHES IN PATIENT CARE
AREAS SHALL UTILIZE TAMPER RESISTANT SCREWS.
SHALL BE 120 VOLTS.
GENERAL NOTES
S
S
J
XX
LO
2W
FA
TEL
FA
1W
ELEVATOR CAB CONNECTIONS
J J J J
FA = FIRE ALARM CONNECTION
TEL = TELEPHONE CONNECTION
LO = LOCKOUT SWITCH FOR CAB LIGHTING
XX
ELEV
ELEVATOR CAB CONNECTIONS
S
SECURITY CAMERA
WIRELESS ACCESS POINT
CARD READER.
INTERCOM. PROVIDE MANUFACTURER BACKBOX
COORDINATE INSTALLATION WITH COMMUNICATION
DEVICE INSTALLER. ALL CABLING IN RACEWAY.
SPEAKER.
TELEPHONE/DATA OUTLET 18"AFF, UNLESS NOTED
OTHERWISE.
ELECTRIC STRIKE
DOOR CONTACT
REQUEST FOR EXIT
MAGNETIC LOCK
DOOR RELEASE. PROVIDE 1/2" CONDUIT TO DOOR
RELEASE BUTTON (DRB).
DOOR RELEASE BUTTON MOUNTED ABOVE COUNTER
FOR A SINGLE DOOR RELEASE.
PROVIDE 1/2" CONDUIT TO DOOR RELEASE.
KEY PAD
WALL MOUNTED TELEPHONE OUTLET 48"AFF,
UNLESS NOTED OTHERWISE.
TELEVISION OUTLET
DOOR RELEASE BUTTON MOUNTED ON WALL.
FOR MAGNETIC DOOR RELEASE. CONNECT TO
DOOR ACCESS SYSTEM.
NURSE CALL DOME LIGHTS
INTERCOM ACCESS WITH VIDEO BY AIPHONE
IX-SERIES www.aiphone.com/products/ix-series
INTERCOM ACCESS WITH VIDEO HEADEND EQUIPMENT
AND ACCESS CONTROL STATION
www.aiphone.com/products/ix-series
KEY OPERATED SWITCH
SWITCH WITH PILOT LIGHT
DIMMER SWITCH WATTAGE AS NECESSARY
P
K
SWITCHES
THREE WAY SWITCH
SINGLE POLE SWITCH. THE NUMBER DENOTES
CIRCUIT NUMBER AND THE LETTER "a"
SWITCH CONTROL
3W
1a
3-WAY DIMMER SWITCH WATTAGE AS NECESSARY
VOLUME CONTROL
"LCC"
"MC"
"LV(2)"
"LM"
LCC
3 a
K
SWITCH LEG TO LTG CONTACTOR COIL "LCC"
LOW VOLTAGE SWITCHING SYSTEM #
QUANTITY OF LV SWITCHES
MASTER SWITCH FOR LOW VOLTAGE
SWITCHING SYSTEM
5 3W,b
MOMENTARY CONTACT SWITCH
"a-z"
"D"
"2P"
"3P"
"3W"
"4W"
"K"
"OS"
"P"
"RS"
SWITCH LEG CONTROL LETTER CODE(S)
DIMMER 1,000W CONTROL SWITCH
DOUBLE-POLE TOGGLE SWITCH
TRIPLE POLE TOGGLE SWITCH
THREE WAY SWITCH
FOUR WAY SWITCH
KEY OPERATED SWITCH
OCCUPANCY SENSOR SWITCH
TOGGLE SWITCH WITH PILOT LIGHT
ROTARY SWITCH WITH TIMER CONTROL
"T"
"WS"
"T/S"
"W-STAT"
THERMAL SWITCH
WALL SWITCH
TEMP/SENSOR SWITCH
WALL LINE VOLTAGE STAT
DS
OC
CEILING MOUNTED PASSIVE INFRARED 360°
DAYLIGHT HARVESTING LIGHT SENSOR
CEILING MOUNTED DUAL
TECHNOLOGY 360° OCCUPANCY
SENSOR
OC WALL MOUNTED DUAL TECHNOLOGY
360° VACANCY/OCCUPANCY SENSOR
D
D3
LOW VOLTAGE CONTACTOR CONTROL SWITCH
TO BE CONNECTED TO THE DELTA CONTROL
PANEL.
LV
PH PHOTOCELL CONTROL
LUMINARIES
F1
2x4 FLUORESCENT/LED LIGHTING
FIXTURE.
1x4 FLUORESCENT/LED LIGHTING
FIXTURE.
FLOURESCENT/LED DOWNLIGHT
OR HIGH BAY.
PARKING LOT FIXTURE
TECHNOLOGY SYMBOLS
CR
I
ES
DC
REX
ML
DR
DRB
KP
W
TV
CEILING MOUNTED DEVICES (W / CIRCLE)
WALL MOUNTED DEVICES (W / STEM)XX
XX
DOOR FRAME MOUNTED DEVICESXX
PROVIDE 4” x 4” x 2-1/2” BACKBOX WITH MUDRING AND 1” CONDUIT TO
ACCESSIBLE CEILING SPACE ABOVE. WHERE AUTHORITY HAVING JURISDICTION
MANDATES PROVIDE CONDUIT CONTINUATION THROUGH PLENUM SPACES.
AI
HE
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
© 2020 Virtual Energy Solutions, INC.
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
-M A
T O
C -J o lie t C
B O
C P a rk in g E x p a n s io n E
L E
C
.r v t
/1 /2
:0
:2
P
M
E001
ELECTRICAL SYMBOLS AND
ABBREVIATIONS
PARKING EXPANSION AT
JOLIET CBOC
10/11/2023
AGSAVSDV
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID 03/24/2023
ISSUED FOR BID ADDENDUM 1 04/21/2023
0.2
0.6
EXISTING JOLIET
CBOC
SECURITY
FENCE
FP
T
T
T
E
E
EE
WALL
1 10
1 2 3 4 5
6 7 8 9
P1 P1
P1
P1
P3 P4
P2 P2
P2 P2
P2
P2
P2
P2
P2
P2
P2
P2 P2
P2
P2
P2
P1
P1
P1
P1
P1
P5
P1
P1
P1
P1
P1
P5
P7
P7
P8 P8
P4 P4
P1
P1
P2 P2 P2
P1
P1
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
© 2020 Virtual Energy Solutions, INC.
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
-M A
T O
C -J o lie t C
B O
C P a rk in g E x p a n s io n E
L E
C
.r v t
/1 /2
:5
:1
P
M
ESD101
ELECTRICAL DEMOLITION SITE
PLAN
PARKING EXPANSION AT
JOLIET CBOC
10/11/2023
AGSAVSDV
1/32" = 1'-0"
1 DEMO SITE LIGHTING
KEYNOTES:
1. DEMOLISH COMPLETE BACK TO SOURCE ALL EXTERIOR PANELS,
POLES, LIGHT FIXTURES, POLE BASES, CONDUITS, CABLING, POWER
CIRCUITS, AND ANCILLARY EQUIPMENT BACK TO SOURCE. EXISTING
EQUIPMENT NOT SHOWN ON PLANS SHALL REMAIN. PROVIDE WIRING
CONTINUITY FOR ALL DEVICES TO REMAIN. VERIFY QUANTITIES IN
FIELD PRIOR TO SUBMITTING BID. COORDINATE DEMOLITION OF ALL
EQUIPMENT WITH ARCHITECT, ENGINEER AND OWNER PRIOR TO
START OF DEMOTION THROUGH SHOP DRAWING SUBMITTAL. PROVIDE
FOR WIRING CONTINUITY FOR ALL EXISTING DEVICES TO REMAIN.
Revisions Date
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID 03/24/2023
0.2
0.6
FP
(V A C A T E D
ASPHALT
PARKING
AREA
ASPHALT
PARKING
AREA
ASPHALT
ROAD
11218
1 10
1 2 3 4 5
6 7 8 9
11.005.00 11.0011.00
11.00
SL5
SL5
SL5
SL5
SL5
SL5
B5
B5
B5
B5
B5
RP-QD1
27,29
S3
CALL BOX
RP-QD1
S3
CALL BOX
RP-QD1
S3
CALL BOX
RP-
QD1-24
W4
RP-QD1
31,33
RP-QD1
21,23
RP-QD1
21,23RP-QD1
21,23
RP-QD1
21,23
RP-QD1
21,23
RP-QD1
27,29
RP-QD1
27,29
RP-QD1
27,29
RP-QD1
27,29
RP-QD1
27,29
W4
RP-QD1
31,33
W4
RP-QD1
31,33
W4
RP-QD1
31,33
W2
RP-QD1
31,33
W2
RP-QD1
31,33
W2
RP-QD1
31,33
W4
RP-QD1
31,33
W4
RP-QD1
31,33
SL4s
RP-QD1
27,29
SL4s
LP1-A
17,19
SL5
LP1-A
17,19
SL5
LP1-A
17,19
SL5
LP1-A
17,19
SL5
RP-QD1
35,37
SL5
RP-QD1
35,37
SL5
RP-QD1
35,37
SL5
RP-QD1
35,37
SL5
LP1-A
13,15
SL5
LP1-A
13,15
SL3s
LP1-A
13,15
SL3s
LP1-A
13,15
SL5
LP1-A
1,3
SL5
LP1-A
1,3
SL5
LP1-A
1,3
SL5
LP1-A
1,3
SL4s
LP1-A
1,3
SL4s
LP1-A
1,3
SL5
RP-QD1
20,22
SL5
RP-QD1
20,22
SL5
RP-QD1
20,22
SL5
RP-QD1
20,22
SL3s
RP-QD1
20,22
S3
CALL BOX
RP-
QD1-24
SL5
LP1-A
13,15
SL4s
LP1-A
17,19
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
© 2020 Virtual Energy Solutions, INC.
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
-M A
T O
C -J o lie t C
B O
C P a rk in g E x p a n s io n E
L E
C
.r v t
/1 /2
:5
:1
P
M
ES101
ELECTRICAL SITE PLAN
PARKING EXPANSION AT
JOLIET CBOC
10/11/2023
AGSAVSDV
1/32" = 1'-0"
1 ELECTRCIAL SITE PLAN
0 16' 32' 64'
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID 03/24/2023
ISSUED FOR BID ADDENDUM 1 04/21/2023
ISSUED FOR BID ADDENDUM 3 10/11/2023
GENERAL NOTES:
1. FOR SECURITY CALL BOX PROVIDE A SEPARATE PHASE AND
NUETRAL CONDUCTOR 2#6 & 1#8 GROUND IN 1" CONDUIT AND CIRCUIT
TO LIGHTING POLE CIRCUIT AHEAD OF SWITCHING AND LIGHTING
CONTROLS. POWER SHALL NOT BE INTERRUPTED BY CONTROLS.
2. ALL EXTERIOR LIGHTING FIXTURES SHALL BE CIRCUITED THROUGH
RELAY PANELS LCP-NORTH AND LCP-SITE. MINIMUM CIRCUIT FEEDER
SHALL BE 2#6 AND 1#8 GROUND IN 1" CONDUIT MINIMUM.
3. MAINTAIN EXISTING EXTERIOR FIXTURE AND CONTROLS FEED
THROUGH EXISTING PANEL LP1A FOR ALL PARKING LOT LIGHTS,
BOLLARDS, PUMPS, CANOPY LIGHTS, ETC. TO REMAIN. PROVIDE FOR
WIRING CONTINUITY FOR ALL DEVICES TO REMAIN. FOR NEW
FIXTURES PROVIDE NEW POLE BASE, CONDUIT & WIRE, CIRCUITS,
ETC. CIRCUIT NEW DEVICES THROUGH NEW LIGHTING CONTROL
PANELS LCP-SITE AND LCP-NORTH.
SD SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SDSDSD
SD
SD
SD
SD
SD
SD
Dx
Ex
Gx
Hx
Jx
Kx
K'x
Lx
1x 4x 6x 9x 12x 13x 14x
Cx
Bx
Ax
A1x
3x 5x 5.8x 8x 10x6.1x
Fx
A.E
15x
15y
15z 15aa
15bb
15cc
15dd
15ee
15ff
15gg15hh
15ii
9.5x1.2x
A
1 2
B
M
M
M
M
M
M
EXISTING
DEMOLITION
NEW
PHASE LEGEND
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
© 2020 Virtual Energy Solutions, INC.
N
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
-M A
T O
C -J o lie t C
B O
C P a rk in g E x p a n s io n E
L E
C
.r v t
/1 /2
:5
:3
P
M
ED100-N
BASEMENT LEVEL - ELECTRICAL
DEMOLITION PLAN - NORTH
PARKING EXPANSION AT
JOLIET CBOC
10/11/2023
AGSAVSDV
1/8" = 1'-0"
2 BASEMENT LEVEL - ELECTRICAL DEMOLITION PLAN - NORTH
GENERAL NOTES:
1 FOR ELECTRICAL DEVICES IN THIS ROOM REMOVE CONDUIT, WIRE AND ANCILLARY
ELECTRICAL DISTRIBUTION EQUIPMENT BACK TO SOURCE. LABEL EXISTING CIRCUIT
BREAKER AS SPARE.
2. ALL EXISTING EGRESS AND EMERGENCY EXIT SIGNS SHALL REMAIN UNTIL SHELL
SPACE IS TO BE DEVELOPED.
3. REFER TO DEMOLITION PLANS FOR OTHER TRADES AND REMOVE POWER FOR
EQUIPMENT TO BE REMOVED BACK TO SOURCE. LABEL CIRCUIT BREAKERS FEEDING
EQUIPMENT TO BE REMOVED AS SPARE.
4. LABEL EACH CIRCUIT FOR LIGHTING FIXTURES TO BE DEMOLISHED FOR INSTALLATION
OF NEW LIGHTING FIXTURE TO BE CONNECTED TO SAME CIRCUIT. MAINTAIN EXISTING
SWITCHING SCHEME.
0 4' 8' 16'
ELECTRCIAL DEMOLITION KEYNOTES
NUMBER KEYNOTE
2 REMOVE ALL ELECTRICAL DEVICES AS REQUIRED FOR NEW
CONSTRUCTION. MAINTAIN EXISTING CONTROL SCHEMES. CIRCUIT
LIGHTING TO NEW SPACE SUCH THAT FUNCTION MIMICS EXISTING
THROUGH NEW LIGHTING CONTROL PANEL.
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID 03/24/2023
SD
SD
SD
SD
SD
SD
SD
SD
SD
SDSD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
4 4
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
Dx
Ex
Gx
Hx
Jx
Kx
K'x
Lx
1x 4x 6x 9x 12x 13x 14x
Cx
Bx
Ax
3x 5x 5.8x 8x 10x6.1x
Fx
A.E
15x
15y
15z 15aa
15bb
15cc
15dd
15ee
15ff
15gg15hh
15ii
9.5x1.2x
A
1 2
B
AV
AV
W
W
W
W
W
W
W
W
W
W
S
S
S S
S
W
S
S
S S
S
S
S
S S
S
S
S
S
S
S
SS
S
S
S
S
EXR
EXR
EXR
EXR
EXR
M
M
EXR
EXR
M
R R
R
R
R
R
R
R
R
R
R
R
R
R
SP
SP
VS
H
H
EXR
EXR
EXR
EXR
R REXR
R
R
R
R
R
R
R
R
R
R
EXISTING
DEMOLITION
NEW
PHASE LEGEND
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
© 2020 Virtual Energy Solutions, INC.
N
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
-M A
T O
C -J o lie t C
B O
C P a rk in g E x p a n s io n E
L E
C
.r v t
/1 /2
:5
:3
P
M
ED101-N
FIRST FLOOR - ELECTRICAL
DEMOLITION PLAN - NORTH
PARKING EXPANSION AT
JOLIET CBOC
10/11/2023
AGSAVSDV
1/8" = 1'-0"
2 FIRST FLOOR - ELECTRICAL DEMOLITION PLAN - NORTH
GENERAL NOTES:
1 FOR ELECTRICAL DEVICES IN THIS ROOM REMOVE CONDUIT, WIRE AND ANCILLARY
ELECTRICAL DISTRIBUTION EQUIPMENT BACK TO SOURCE. LABEL EXISTING CIRCUIT
BREAKER AS SPARE.
2. ALL EXISTING EGRESS AND EMERGENCY EXIT SIGNS SHALL REMAIN UNTIL SHELL SPACE
IS TO BE DEVELOPED.
3. REFER TO DEMOLITION PLANS FOR OTHER TRADES AND REMOVE POWER FOR
EQUIPMENT TO BE REMOVED BACK TO SOURCE. LABEL CIRCUIT BREAKERS FEEDING
EQUIPMENT TO BE REMOVED AS SPARE.
4. LABEL EACH CIRCUIT FOR LIGHTING FIXTURES TO BE DEMOLISHED FOR INSTALLATION
OF NEW LIGHTING FIXTURE TO BE CONNECTED TO SAME CIRCUIT. MAINTAIN EXISTING
SWITCHING SCHEME.
0 4' 8' 16'
ELECTRCIAL DEMOLITION KEYNOTES
NUMBER KEYNOTE
2 REMOVE ALL ELECTRICAL DEVICES AS REQUIRED FOR NEW
CONSTRUCTION. MAINTAIN EXISTING CONTROL SCHEMES. CIRCUIT
LIGHTING TO NEW SPACE SUCH THAT FUNCTION MIMICS EXISTING
THROUGH NEW LIGHTING CONTROL PANEL.
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID 03/24/2023
Elev. Equip.
B003
Badge
B004
Phone
B002C
Home Based Primary
Care
B002
Stair #2
S-2
Comm.
B005
Reception
B001
Women's Restroom
B006
Men's Restroom
B011
HAC
B007
Copy Room
B009
Phone
B002A
Phone
B002B
Phone
B017
Phone
B016
A.O.
B015
Clinical Nurse Manager
B014
Chief Medical Director
B013
Patient Education/Group
Room
B011
Patient
Education/Exercise
B022
Store
B012
Corridor
C0-2
Corridor
C0-3
Corridor
C0-4
Corridor
C0-1
Mech.
B018
Elec.
B019
Gen Room
B020
PAS Call Center
B024
Education Storage
B022
Nutrition Services
B021
Main Conference Room
B023
Mech.
B025
Patient Education/Group
Room
B033
Patient Education/Group
Room
B032 Patient Ed/Internet Cafe
B031
Elec.
B028
Elevator
EL-1
New North Vestibule
Vending
Cooking Classroom
0023A
Elec.
B026B
Lobby
Elevator-2
E-2-2
Dx
Ex
Gx
Hx
Jx
Kx
K'x
Lx
1x 4x 6x 9x 12x 13x 14x
Cx
Bx
Ax
A1x
3x 5x 5.8x 8x 10x6.1x
Fx
A.E
15x
15y
15z 15aa
15bb
15cc
15dd
15ee
15ff
15gg15hh
15ii
9.5x1.2x
A
1 2
B
F1A F1A F1A
F1A F1A
F2A
F2A
F2AF2AF2A
F2A
F2A
EX-1
EX-1EX-1
EX-1
11 RP-QD1 11 RP-QD1 11 RP-QD1
11 RP-QD111 RP-QD1
12 RP-QD1
12 RP-QD1
12 RP-QD112 RP-QD112 RP-QD1
EM1
EM1
EM1
EX-1
F7
12 RP-QD1
13 RP-QD1
12 RP-QD1
12 RP-QD1
12 RP-QD1
a b
ETR
ETR
ETR
ETR ETR
ETRETR
ETR ETR ETR
ETR
ETR
ETR
11 RP-QD1
12 RP-QD1
EXISTING
DEMOLITION
NEW
PHASE LEGEND
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
© 2020 Virtual Energy Solutions, INC.
N
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
-M A
T O
C -J o lie t C
B O
C P a rk in g E x p a n s io n E
L E
C
.r v t
/1 /2
:5
:4
P
M
EL100-N
BASEMENT LEVEL - ELECTRICAL
LIGHTING PLAN - NORTH
PARKING EXPANSION AT
JOLIET CBOC
10/11/2023
AGSAVSDV
1/8" = 1'-0"
1 BASEMENT LEVEL - ELECTRICAL LIGHTING PLAN - NORTH
GENERAL LIGHTING NOTES:
1. SEE DRAWING E001 FOR SYMBOLS.
2. CONNECT NEW AND EXISTING TO BE REMOVED AND REINSTALLED LIGHT
FIXTURES TO EXISTING CIRCUIT MADE SPARE DUE TO DEMOLITION UNLESS
INDICATED OTHERWISE. MAINTAIN EXISTING SWITCHING SCHEME. LIGHT
FIXTURES ARE LESS WATTAGE THAN EXISTING TO BE DEMOLISHED. PROVIDE
FOR NEW LIGHTING CONTROLS AS DIRECTED ON LIGHTING CONTROLS RISER
DIAGRAM #1/E603.
3. CONTRACTOR SHALL PATCH, REPAIR AND FINISH WALLS WHERE DEVICES
HAVE BEEN REMOVED RELOCATED AND/OR REPLACED TO MATCH EXISTING
SUCH THAT WORK IS NOT DISTINGISHABLE FROM EXISTING CONDITIONS.
4. PROVIDE RELAY PANEL FOR LIGHTING CONTROLS. MATCH EXISTING
CONTROLS AND SWITCHING SCHEMES. PROVIDE FOR WIRING CONTINUITY
FOR ALL DEVICES TO REMAINING.
0 4' 8' 16'
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID 03/24/2023
ISSUED FOR BID ADDENDUM 1 04/21/2023
ISSUED FOR BID ADDENDUM 2 07/21/2023
ISSUED FOR BID ADDENDUM 3 10/11/2023
LIGHTING KEYNOTES
NUMBER KEYNOTE
1 CONNECT…