This solicitation is for the expansion of parking structure at the Joliet Community Based Outpatient Clinic located in Joliet, Illinois. The work includes construction of a new north vestibule and renovations to the existing structure. The Department of Veterans Affairs Technology Acquisition Center in Austin, Texas issued the solicitation. Responses are due on various dates specified in the document. The awarded contractor will be responsible for building additions, roof repairs, masonry work, interior renovations, and mechanical and electrical upgrades. Pricing will be fixed-price for the base work and unit priced for additional work. The solicitation number is 36C77624B0009.

View the file

Other files

File Type Posted
36C77624B0009 0011 signed.pdf PDF
Joliet CBOC Parking Expansion - Bid Opening Attendance.pdf PDF
S07 - Abstract of Bids OF 1419 Joliet -S.pdf PDF
Amend 0010 ATT 1 - 578-371 Joliet CBOC Addendum 3 PM R 240502.pdf PDF
36C77624B0009 0010 signed.pdf PDF
36C77624B0009 0009.pdf PDF
Joliet CBOC Technical Questions 1-41 VA Responses Final.pdf PDF
36C77624B0009 0008.pdf PDF
36C77624B0009 0007.pdf PDF
S05 - Joliet CBOC - Technical Questions - Updated 041524.pdf PDF
13974 - Joliet Geotechnical Report.pdf PDF
S05 - Joliet CBOC - Technical Questions 1-41 VA Responses.pdf PDF
26 24 13 Distribution Switchboards.pdf PDF
36C77624B0009 0006.pdf PDF
26 05 73 Overcurrent Protective Device Coordination Study.pdf PDF
26 22 00 Low Voltage Transformers.pdf PDF
13974 - Proposed Parking Addition REV01.pdf PDF
26 24 16 Panelboard.pdf PDF
Pre-bid Site Visit 2 Sign-in Sheet.pdf PDF
36C77624B0009 0005.pdf PDF
36C77624B0009 0004.pdf PDF
36C77624B0009 0003.pdf PDF
Updated - Wage Rates - Will County 2.23.24.pdf PDF
Site Visit 2 Details.pdf PDF
578-371 Pre-bid Site Visit 031824.pdf PDF
36C77624B0009 0002.pdf PDF
Att - 4 -578-371_Joliet_CBOC_Add_3_Part_3_R1.pdf PDF
36C77624B0009 0001.pdf PDF
ATT 10 - 578-371_Joliet_CBOC_Add_3_Parts_Index.pdf PDF
ATT 9 - 578-371_Joliet_CBOC_Add_3_Part_8.pdf PDF
ATT 8 - 578-371_Joliet_CBOC_Add_3_Part_7.pdf PDF
ATT 12 - Limitations on Subcontracting.pdf PDF
ATT 7 - 578-371_Joliet_CBOC_Add_3_Part_6.pdf PDF
ATT 13 - Wage Rates - Will County 2.23.24.pdf PDF
S02 - 36C77624B0009 - Solicitation - Joliet Parking Expansion.pdf PDF
ATT 1 - Specifications Book.pdf PDF
ATT 3 - 578-371_Joliet_CBOC_Add_3_Part_2.pdf PDF
ATT 6 - 578-371_Joliet_CBOC_Add_3_Part_5.pdf PDF
ATT 11 - 578-371 Construction SOW Final.pdf PDF
ATT 4 - 578-371_Joliet_CBOC_Add_3_Part_3.pdf PDF
ATT 2 - 578-371_Joliet_CBOC_Add_3_Part_1.pdf PDF
ATT 14 - Site Visit Instructions.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

Ex

GxGx

HxHx

JxJx

KxKx

K'x

Lx Lx

1x 4x 6x 9x 12x 13x 14x3x 5x 5.8x 8x 10x6.1x

Fx

15x9.5x1.2x

AE 304

AE 202

AE 301

A

3 4

B

New North Vestibule

NEW MASONRY EXTERIOR

FINISH AT NORTH EXTERIOR

WALLS

46' - 1" 22' - 5 1/2" 23' - 8 3/4"

42' - 0 3/4" 4' - 6" 41' - 7"

/4

601' - 8 1/2"

AE 302

7' - 10"

Lobby

8' - 0 1/2"

/2

20' - 7"

AE 202 4

AE 2022

LINE OF CANOPY ABOVE

601' - 8 1/2"

5' - 4" RO 6' - 2 1/4"

/4

AE 400

Elevator E-2

6' - 0" 6 1/4" 7' - 2"

13' - 8 1/2"

601' - 8 1/2"

2B

2B2B

AE 201

AE 2012

AE 201 3

AE 304

AE 303

601' - 8 1/2"

Engineering Space

NEW CAST IN PLACE

CONCRETE WALL

/2

601' - 8 1/2"

AE 304

A

B

11 1/4" 2' - 2 1/2" 4' - 4" 2' - 2 3/4"

S2

S2

603' - 3 3/4"603' - 3 3/4"

T/ LOWER RETAINING WALL T/ LOWER RETAINING WALL

AE 205

AE 2058

ALIGN

Mach. Room 003A

A

AE 303

AE 303

D D D D

6" 5' - 4" 5' - 1" RO 7' - 10" 5' - 1" RO 7' - 10" 5' - 1" RO 5' - 4" 13' - 3" 5' - 1" RO 5' - 4" 6"

V A

R

IE

S

AE 2061

AE 206

AE 206

AE 206

6"

B B

A

A

A

7' - 2"

NEW RETAINING WALLS

9' - 0" 5' - 4" RO 5' - 6"

B

2 2 2

3 33 3

33 3

CG

CG

/4

Elev. Equip.

B003

Badge B004

Phone B002C

Home Based Primary Care

B002

Stair #2 S-2

Comm.

B005

Reception B001

Women's Restroom

B006

Men's Restroom

B008

HAC

B007

Copy Room B009

Phone B002A

Phone B002B

Phone B017

Phone B016

A.O.

B015

Clinical Nurse Manager

B014

Chief Medical Director

B013

Store B012

Corridor C0-2

Corridor C0-1

Elevator

EL-1

Mech.

B018

SYMBOLS LEGEND

Room name

KEYNOTE

ROOM NAME/NUMBER

0X

CENTERLINE

1i

PARTITION TAG: SEE SHEET AE 501, PARTITION

TYPES & DETAILS FOR MORE INFORMATION

SPOT FLOOR

ELEVATION

NEW COLUMN

GRID LINE

EXISTING COLUMN

GRID LINE

NEW CONSTRUCTION

EXISTING CONSTRUCTION TO REMAIN

1-HOUR RATED CONSTRUCTION

2-HOUR RATED CONSTRUCTION

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

CONCRETE WALL

CMU - CONCRETE MASONRY UNITS

EXTERIOR RIGID INSULATION

CG

CORNER GUARD FINISH TAG: SEE SHEET

AI 601, FINISH PLANS & FINISH SCHEDULE

FOR DETAILED FINISHES INFORMATION

1i

STOREFRONT / WINDOW TAG: SEE SHEET

AE 602 WINDOW & STOREFRONT SCHEDULE

& DETAILS FOR SPECIFIC INFORMATION

DOOR TAG: SEE SHEET AE 601, DOOR

SCHEDULE & DETAILS SHEET FOR SPECIFIC

DOOR INFORMATION

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :4

P

M

AE 100

BASEMENT LEVEL PLAN NORTH

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/4" = 1'-0"

1 BASEMENT LEVEL PLAN - NORTH WALL

0 2' 4' 8'

ARCHITECTURAL KEYNOTES NEW WORK BASEMENT

KEY KEYNOTE

1 INFILL OPENING ONCE ELEVATOR IS INSTALLED. VERIFY WITH ELEVATOR MANUFACTURER.

2 PATCH AND REPAIR EXISTING GWB, METAL STUD FRAMING AT EACH NEW WINDOW & DOOR OPENING.

3 L6x4x3/8" GALVANIZED STEEL FRAME AT EACH WINDOW 'D', BASEMENT LEVEL

4 PREFINISHED METAL DOWN SPOUT

5 STEEL COLUMNS, WITH SPRAY APPLIED FIRE PROOFING, 2-HOUR

6 72" TURNING CIRCLE

7 48" x 48" DOOR APPROACH CLEARANCE

8 48" x 60" DOOR APPROACH CLEARANCE

9 54" x 60" DOOR APPROACH CLEARANCE

10 66" x 72" DOOR APPROACH CLEARANCE

AREA OF

WORK

AREA OF WORK

AREA OF WORK.

SEE CIVIL &

LANDSCAPE DRAWINGS

FOR SITEWORK

AREA OF WORK

AREA OF WORK

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

ADDENDUM 3 REVIEW 09/22/2023

ADDENDUM 3 ISSUED FOR BID 10/11/2023

UP

GxGx

HxHx

JxJx

KxKx

K'xK'x

Lx Lx

1x 4x 6x 9x 12x 13x 14x3x 5x 5.8x 8x 10x6.1x

Fx

15x9.5x1.2x

AE 304

AE 202

A

3 4

B

42' - 0 3/4"

/4

4' - 6"

22' - 5 1/2"

-H

O U

R

AE 302

Lobby

Alcove 102A

AE 202 4

AE 2022

AE 401

Elevator E-2

104A

ROOF OF NEW NORTH

VESTIBULE BELOW

CANOPY BELOW

Office

E Q

E Q

Vestibule

/4

8' - 9 3/4"

13' - 6 1/2" 4 1/4"

13' - 8 1/4"

/4

104B

Corridor C1-15A

2B

2B

2B

2B

2B

2B

2B

AE 201

AE 2012

AE 201 3

AE 304

AE 303

8' - 4 1/4"

2B

2B

2B

-H

O U

R

2-HOUR

ALIGN

AE 304

/4

M O

C M

U

/4

C

D C

D D D

C

Storage 1116A

7' - 1 1/2"

/2

/2

11" 2' - 2 1/2" 5"

1116A

/4

AE 208

AE 208

AE 208

AE 207

AE 207 6

AE 303

AE 303

AE 402

AE 402

ALIGN

A L

IG

N

D

4' - 0" 8' - 8" 6' - 2" 7' - 0 7/8"

/4

1' - 8 1/4" 4' - 0" 3' - 3 1/2" 1' - 4" 14' - 10" 1' - 4" 12' - 10 3/4" 6' - 7 5/8" 4' - 8 3/8"4' - 8 3/8"

AE 202

2' - 4" 1' - 4" 5' - 0" 2' - 6" 1' - 4" 2' - 4"

MO CMU

5' - 0"

MO CMU

5' - 0"

MO CMU

5' - 0"

MO CMU

5' - 0"

MO CMU

5' - 0"

MO CMU

5' - 0" 2' - 0"

2' - 7" 1' - 4" 2' - 8"

MO CMU

5' - 0"

4"

4"

4"

14' - 5"

C -1

B

CG

CG CG

NEW WINDOW

AREA OF WORK

AREA OF WORK

AREA OF WORK

FMS

Elevator

EL-1

Stair #2 S-2

Corridor C1-15

Rad Control

Dispensary

Diagnostic

Marco

Rad Room

Corridor C1-10

Clean Utility

Soiled Utility

Control

Sound Booth

Control

Sound Booth

Stor.

Elec. Clos.

1089A

Elec.

Corridor

C1-14

SYMBOLS LEGEND

Room name

KEYNOTE

ROOM NAME/NUMBER

0X

CENTERLINE

1i

PARTITION TAG: SEE SHEET AE 501, PARTITION

TYPES & DETAILS FOR MORE INFORMATION

SPOT FLOOR

ELEVATION

NEW COLUMN

GRID LINE

EXISTING COLUMN

GRID LINE

NEW CONSTRUCTION

EXISTING CONSTRUCTION TO REMAIN

1-HOUR RATED CONSTRUCTION

2-HOUR RATED CONSTRUCTION

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

CONCRETE WALL

CMU - CONCRETE MASONRY UNITS

EXTERIOR RIGID INSULATION

CG

CORNER GUARD FINISH TAG: SEE SHEET

AI 601, FINISH PLANS & FINISH SCHEDULE

FOR DETAILED FINISHES INFORMATION

1i

STOREFRONT / WINDOW TAG: SEE SHEET

AE 602 WINDOW & STOREFRONT SCHEDULE

& DETAILS FOR SPECIFIC INFORMATION

DOOR TAG: SEE SHEET AE 601, DOOR

SCHEDULE & DETAILS SHEET FOR SPECIFIC

DOOR INFORMATION

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :5

P

M

AE 101

FIRST FLOOR PLAN NORTH

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/4" = 1'-0"

1 FIRST FLOOR LEVEL PLAN - NORTH WALL

ARCHITECTURAL KEYNOTES

KEY KEYNOTE

1 PATCH AND REPAIR EXISTING WALL AT LOCATION OF DEMOLISHED ROOF ACCESS LADDER

2 INFILL EXISTING CMU WALL , MATCH EXISTING BLOCK SIZE. PAINTED FINISH

3 ALIGN NEW CONSTRUCTION & FINISHES WITH EXISTING

4 REINSTALL EXISTING SINK, MILLWORK, AND COUNTER. SCRIBE BACKSPLASH TO NEW WALL.

5 NEW PREFABRICATED METAL ROOF ACCESS STAIR. PROVIDE LOCKABLE GATE.

6 JOINT LINE BETWEEN EXISTING CBOC AND NEW WORK

7 72" TURNING CIRCLE

8 48" x 48" DOOR APPROACH CLEARANCE

9 48" x 60" DOOR APPROACH CLEARANCE

10 54" x 60" DOOR APPROACH CLEARANCE

11 66" x 72" DOOR APPROACH CLEARANCE

0 2' 4' 8'

AREA OF

WORK

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

C

GxGx

HxHx

JxJx

KxKx

K'x K'x

Lx

1x 4x 6x 9x 12x 13x 14x

Cx

Bx

Ax

3x 5x 5.8x 8x 10x6.1x

A.E

15x9.5x1.2x

AE 304

AE 301

A

3 4

B

EXISTING BOILER PLANT

EXISTING ROOFING TO BE REPLACED,

16,997 SF

NEW CMU PARAPET

43' - 2" N E

W C

M U

P A

R A

P E

T

/4

2'

4' - 11 3/4" 87' - 2 1/2" NEW CMU PARAPET AT CBOC NORTH WALL

EXISTING AREAWAY AT 1ST FLOOR BELOW

0'

/4

45' - 10 3/4" 75' - 10 1/2"

8'

/4

/4

20' - 7"

CANOPY BELOW

628' - 10 1/2"

LINE OF EXISTING EXPANSION JOINT

BETWEEN NORTH & SOUTH

PORTION OF CBOC

EXISTING ROOF ACCESS

HATCH:

INFILL OPENING

22' - 5 1/2"

EXISTING ACCESS

STEPS FROM NORTH

ROOF UP TO SOUTH

ROOF

AE 302

ELEVATOR OVER RIDE

1/4" PER

FOOT

1/4" PER

FOOT

NEW ROOF STRUCTURE

33' - 0"

18' - 10 1/4"

E X

IS

T

IN

G

R O

O F

S T

R U

C T

U R

E T

O R

E M

A

IN

NEW NORTH VESTIBULE BELOW

ROOF DECK

R1

R1R1

R1R1

R8

R1

R1

R1 R1

R1

R2

R3

R3

R4

R4

R5

R5

R5

R5

R5

R5

R5 R5

R5

R5

R5

R7

R7

R7

R7

R7

1 2

F

AE 402

/1 AE 102S

1/ 2"

R9

R9

R9

AE 102N

AE 102N

R7

R1R1

R1 R1

47' - 10"

R1

R1

R1

EXISTING ROOF STRUCTURE

EXISTING ROOF DRAIN

NEW MEMBRANE ROOF SYSTEM

NEW TAPERED INSULATION

EXISTING STRAINER, INSPECT.

REPLACE DAMAGED STRAINERS

EXISTING ROOF STRUCTURE

NEW OVER FLOW ROOF

DRAIN

NEW ROOF DRAIN

BODY

NEW MEMBRANE ROOF SYSTEM

NEW TAPERED INSULATION

NEW STRAINERS

ROOF LEGEND

NEW ROOFING SYSTEM

NEW CONSTRUCTION

NEW ROOF DRAIN WITH

OVERFLOW

OVERFLOW ROOF

DRAIN

EXISTING ROOF DRAIN

ROOF KEYNOTERn

EXISTING CONSTRUCTION

ROOF NORTH

628' - 10 1/2"

ROOF SOUTH

631' - 2 1/2"

Bx

EXISTING 2-HOUR

RATED FIRE BARRIER.

INSPECT FOR DAMAGE

EXISTING CMU PARAPET

EXISTING BRICK PARAPET

EXISTING CAST-IN-PLACE

CONCRETE ROOF STRUCTURE,

NORTH PORTION

EXISTING METAL DECK & CONCRETE

COMPOSITE ROOF, SOUTH PORTION

EXISTING STEEL BEAM

REINSTALL EXISTING EXPANSION JOINT

ASSEMBLY. REPLACE ANY MISSING OR

DAMAGED GASKETS.

NEW METAL FLASHING

NEW TPO ROOFING SYSTEM

CONTINUOUS FIBER CANT

TAPERED RIGID INSULATION

NEW TPO ROOFING SYSTEM,

WRAP OVER PARAPET

CONTINUOUS FIBER CANT

TAPERED RIGID INSULATION

2X PT WOOD BLOCKING

2X PT WOOD BLOCKING

NEW PREFINISHED METAL COPING

DRAPE TPO MEMBRANE ACROSS GAP TO

ALLOW FOR MOVEMENT

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :5

P

M

AE 102N

ROOF PLAN - NORTH PORTION

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/8" = 1'-0"

1 ROOF NORTH

ROOF KEYNOTES

KEY KEYNOTE

R1 REPLACE EXISTING ROOF DRAIN IRON STAINERS. INSPECT EXISTING DRAIN BODY

FOR DAMAGE.

R2 NEW ROOF DRAIN AND OVER FLOW

R3 NEW SCUPPER & DOWNSPOUT, PREFINISHED

R4 ABANDONED CURB, VERIFY IN FIELD

R5 NEW PREFINISHED ALUMINUM COPING & PRESSURE TREATED WOOD BLOCKING

R6 NOT UESD

R7 EXISTING MECHNICAL EQUIPMENT, SEE MECHNICAL SHEETS

R8 NEW ROOF DRAIN & LEADER CONNECTION

R9 WALK PADS BY ROOFING MANUFACTURER. CONFIRM FINAL LAYOUT WITH COR.

NOTES:

1. REMOVE EXISTING ROOF MEMBRANE, PROTECTION BOARD, INSULATION, FLASHING,

COPING, AND ACCESSORIES. PREPARE EXISTING ROOF DECK TO RECEIVE NEW ROOFING

SYSTEM PER ALL MANUFACTURER'S REQUIREMENTS.

2. NEW ROOFING SYSTEM SHALL BE FULLY ADHERED TPO MEMBRANE OVER POLYISO RIGID

INSULATION MINIMUM R-39 CONTINUOUS VALUE. ROOF INSULATION SHALL SLOPE TO

DRAINS A MINIMUM OF 1/4" PER FOOT.

3. PROVIDE CRICKETS AT ALL EQUIPMENT THAT DIRECT WATER AWAY FROM SUCH

ELEMENTS.

4. EXISTING PIPE PENETRATIONS (3" - 4" IN DIAMETER). PROVIDE PRICING FOR

18 SUCH PENETRATIONS AND A UNIT PRICE FOR ADDITIONAL PENETRATIONS.

1 1/2" = 1'-0"

3 EXISTING ROOF DRAIN

1 1/2" = 1'-0"

4 NEW ROOF DRAIN WITH OVER FLOW

Rn

0 1'½' 1 ½'

0 1'½' 1 ½'

0 4' 8' 16'

1" = 1'-0"

DETAIL SECTION AT NORTH-SOUTH EXISTING EXPANSION JOINT 2'0 1'1/2'

AREA OF

WORK

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

ISSUED FOR BID ADDENDUM 1 04/21/2023

1x

1x

4x

4x

6x

6x

9x

9x

12x

12x 13x

14x

14x

Bx

Ax

A1x

B1x

C1x

D1x

E1x

3x 5x

A.E

15x1.2x

R 18' - 9 3/4"

EXISTING STANDING SEAM

METAL ROOF OVER

STAIR #1 - TO REMAIN

EXISTING CHILLERS ON EXPOSED STEEL

FRAME

ADD ALTERNATE:

REROOF EXISTING UPPER CANOPY

AT MAIN ENTRY:

2,163 SF

EXISTING LOW-SLOPED ON

ROTUNDA CLERESTORY, TO BE REROOFED

EXISTING ROOFING TO BE REPLACED,

16,654 SF

REPLACE EXISTING METAL COPING,

FINISH TO MATCH EXISTING, TYPICAL

1'

63' - 7 3/4" 58' - 4"

ROOF OF ROTUNDA STRUCTURE,

1,113 SF

EXISTING EXPANSION JOINT

BETWEEN NORTH & SOUTH

PORTION OF CBOC

631' - 2 1/2"

641' - 2 1/2" 633' - 6 1/2"

628' - 10 1/2"

EXISTING ACCESS

STEPS FROM NORTH

ROOF UP TO SOUTH

ROOF

4'

0" 2'

6'

" NORTH ROOF CBOC

SOUTH ROOF CBOC

HIGH POINT

R5

R5

R5

R5

R5 R5 R5

R5

R5

R5

R5

LOWER CANOPY ROOF

230 SF

R7

R7

R7

R7

R7

R7

ROOF DECK

ROOF DECK

ROOF DECK

ROOF DECK

/1 AE 102N

R9

R9

R9

AE 102N

AE 102N

EXISTING ROOF STRUCTURE

EXISTING OVER FLOW ROOF

DRAIN

EXISTING ROOF DRAIN

NEW MEMBRANE ROOF SYSTEM

NEW TAPERED INSULATION

EXISTING STRAINER, INSPECT.

REPLACE DAMAGED STRAINERS

ROOF LEGEND

NEW ROOFING SYSTEM

NEW CONSTRUCTION

NEW ROOF DRAIN WITH

OVERFLOW

OVERFLOW ROOF

DRAIN

EXISTING ROOF DRAIN

ROOF KEYNOTERn

EXISTING CONSTRUCTION

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :0

P

M

AE 102S

ROOF PLAN - SOUTH PORTION

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/8" = 1'-0"

ROOF SOUTH

ROOF KEYNOTES

KEY KEYNOTE

R1 REPLACE EXISTING ROOF DRAIN IRON STAINERS. INSPECT EXISTING DRAIN BODY

FOR DAMAGE.

R2 NEW ROOF DRAIN AND OVER FLOW

R3 NEW SCUPPER & DOWNSPOUT, PREFINISHED

R4 ABANDONED CURB, VERIFY IN FIELD

R5 NEW PREFINISHED ALUMINUM COPING & PRESSURE TREATED WOOD BLOCKING

R6 NOT UESD

R7 EXISTING MECHNICAL EQUIPMENT, SEE MECHNICAL SHEETS

R8 NEW ROOF DRAIN & LEADER CONNECTION

R9 WALK PADS BY ROOFING MANUFACTURER. CONFIRM FINAL LAYOUT WITH COR.

NOTES:

1. REMOVE EXISTING ROOF MEMBRANE, PROTECTION BOARD, INSULATION, FLASHING,

COPING, AND ACCESSORIES. PREPARE EXISTING ROOF DECK TO RECEIVE NEW ROOFING

SYSTEM PER ALL MANUFACTURER'S REQUIREMENTS.

2. NEW ROOFING SYSTEM SHALL BE FULLY ADHERED TPO MEMBRANE OVER POLYISO RIGID

INSULATION MINIMUM R-39 CONTINUOUS VALUE. ROOF INSULATION SHALL SLOPE TO

DRAINS A MINIMUM OF 1/4" PER FOOT.

3. PROVIDE CRICKETS AT ALL EQUIPMENT THAT DIRECT WATER AWAY FROM SUCH

ELEMENTS.

4. EXISTING PIPE PENETRATIONS (3" - 4" IN DIAMETER). PROVIDE PRICING FOR

18 SUCH PENETRATIONS AND A UNIT PRICE FOR ADDITIONAL PENETRATIONS.

1 1/2" = 1'-0"

3 EXISTING ROOF DRAIN WITH OVER FLOW

0 1'½' 1 ½'

Rn

0 4' 8' 16'

AREA OF

WORK

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

JxJx

KxKx

K'xK'x

LxLx

12x 13x 14x10x 15x

A A

3 4

B B

AE 302

New North Vestibule

Lobby

Elevator E-2

22' - 5 1/2" 23' - 8 3/4"

/4

/2

F2A

F1A

F2A F2A

F2A

F2A

CANOPY

EM1

EM1

5'

3/ 4"

4'

13' - 8 1/4"

5' - 4 1/2" 10' - 9" 10' - 9" 5' - 4 1/2"

F1A

F1AF1A

F1A

E Q

E Q

EQ EQ EQ EQ

E Q

E Q

E Q

E Q

Engineering Space

Mach. Room 003A

F2A

F2A

7' - 8"

F3 F3F3

EXISTING GYP. BOARD

SOFFIT TO REMAIN

AFF

ACT 2

10' - 4"

AFF

ACT 1

9' - 0"

AFF

ACT 1

8' - 0"

AFF

EC1

14' - 0"

AFF

EC1

14' - 0"

BOTTOM OF FIXTURE

AT 9'-0" AFF, TYPICAL OF

(4) FOUR

BOTTOM OF FIXTURE

AT 9'-0" AFF, TYPICAL OF

(1) ONE

F7

CEILING AT 1ST FLOOR

ABOVE

Stair #2 S-2

Comm.

B005

Elevator

EL-1

Reception B001

Gx

Hx

Jx

Kx

K'x

Lx

1x 4x 6x3x 5x 5.8x 8x6.1x1.2x

AE 304

AE 304

1'

1'

1'

2' - 7"

2' - 7"

2' - 7"

CEILING POCKET

15' - 0"

CEILING POCKET

10' - 10"

CEILING POCKET

10' - 10"

C E

IL

IN

G P

O C

K E

T

C E

IL

IN

G P

O C

K E

T

6'

AFF

ACT 1

8' - 0" AFF

ACT 1

8' - 0"

AFF

ACT 1

8' - 0"

AFF

ACT 1

8' - 6"

AFF

ACT 1

8' - 6"

AFF

ACT 1

9' - 0"

AFF

ACT 1

9' - 0"

AFF

ACT 1

9' - 0"

AFF

ACT 1

9' - 0"

AFF

ACT 1

9' - 0"

AC 501

NO WORK IN THESE

ROOMS

EXISTING SOFFIT &

LIGHT FIXTURE TO REMAIN

NO WORK IN THIS ROOM

X X X X X X

X X

X X

X

X

X

Elev. Equip.

B003

Badge B004

Home Based Primary Care

B002

Reception B001

Phone B002A

Phone B002B

Phone B017

Phone B016

A.O.

B015

Clinical Nurse Manager

B014

Chief Medical Director

B013

Corridor C0-2

RCP NOTES

A. SEE CEILING TYPES FOR LOCATION OF EXISTING GRID AND

TRIM TO REMAIN

B. ROOM LIGHTS ARE TO BE REPLACED. SEE ELECTRICAL

SHEETS FOR FIXTURE INFORMATION.

C. REINSTALL THE FOLLOWING (BUT NOT LIMITED TO) CEILING

MOUNTED DEVICES, ITEMS, & FIXTURES IN THEIR PREVIOUS

LOCATION:

a. SMOKE & HEAT DETECTORS

b. CAMERAS

c. WI-FI ANTENNAS

d. SPEAKERS

e. MIRRORS

f. EMERGENCY LIGHTS

g. NURSE CALL LIGHTS

h. SIGNS

i. DIFFUSERS AND GRILLES

j. VISUAL FIRE ALARMS

k. ARTWORK

l. SPRINKLER HEAD TRIM RINGS

m. CURTAIN TRACKS

n. MED GAS LINE ESCUTCHEONS

o. CEILING MOUNTED EXAM LIGHTS

D. GYPSUM BOARD SOFFITS & CEILINGS: REPAIR ANY DAMAGE

AS A RESULT OF ADJACENT GENERAL DEMOLITION OR

CONSTRUCTION WORK UNDER THIS CONTRACT.

E. PRESERVE AND PROTECT EXISTING CEILING GRID AND TRIM

IN INDICATED LOCATIONS.

F2A 2X2 LED TROFFER LIGHT

F1A 4' LED STRIP SUSPENDED

NEW CONSTRUCTION

EXISTING CONSTRUCTION TO REMAIN

Room name

KEYNOTEX

ROOM NAME/NUMBER

0X

CENTERLINE

EC1: EXPOSED CONSTRUCTION

RCP SYMBOLS LEGEND

NEW WORK

F1A

F3

NEW COLUMN

GRID LINE

EXISTING COLUMN

GRID LINE

LED EXIT SIGN

LED EMERGENCY LIGHT W/90 BATTERY

BACKUP

EM1

EX1

LIGHTING

CEILING TYPES

CEILING TYPE &

CEILING ELEVATION8'-0" AFF

ACT1

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

ACT 2: NEW 2X2 LAY-IN

ACOUSTICAL CEILING TILE WITH

NEW GRID AND EDGE TRIM.

ABUSE RESISTANT TILE

GBX: EXISTING GYPSUM BOARD

CEILING OR SOFFIT.

F2A

F3 4" RECESSED CAN DOWNLIGHT,

WET LOCATION TYPE

F7 WALL MOUNTED LED STRIP

LIGHT, WET LOCATION TYPE

F7

ACT 1: NEW 2X2 LAY-IN

ACOUSTICAL CEILING TILE WITH

NEW GRID AND EDGE TRIM

EXISTING 2X2 CEILING SYSTEM

TO REMAIN

EXISTING 2X2 LED TROFFER LIGHT

TO REMAIN

EXISTING 2X4 LED TROFFER LIGHT

TO REMAIN

EXISTING 2X2 LED TROFFER LIGHT

TO BE REINSTALLED

EXISTING 2X4 LED TROFFER LIGHT

TO BE REINSTALLED

EXISTING CAN LIGHT

TO REMAIN

X

X

EXISTING CAN LIGHT

TO BE REINSTALLED

X

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :0

P

M

AC 100

REFLECTED CEILING ENLARGED

PLANS-BASEMENT LEVEL

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/4" = 1'-0"

2 BASEMENT LEVEL REFLECTED CEILING PLAN

CEILING SCHEDULE

TAG

MANUFACTURER

(BASIS OF DESIGN) DESCRIPTION COMMENTS

ACT 1 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM NEW TILE, GRID, & TRIM: USG 'MARS' SERIES

ACT 2 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM NEW TILE, GRID, & TRIM - ABUSE RESISTANT TILE. USG

'FROST' SERIES

GB1 VARIES GYPSUM BOARD CEILING AND SOFFITS, PAINT P4

GBX VARIES EXISTING TO REMAIN PATCH AND REPAIR DAMAGE AS NEEDED

1/4" = 1'-0"

BASEMENT LEVEL REFLECTED CEILING PLAN

0 2' 4' 8'

0 2' 4' 8'

AREAS OF

WORK

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

ISSUED FOR BID ADDENDUM 1 04/21/2023

Gx

Hx

JxJx

KxKx

K'xK'x

Lx

12x 13x 14x10x 15x

15y

Office

Vestibule

Alcove 102A

Lobby

Elevator E-2

Corridor C1-15A

F2A

F2A

F2A

F2A

F2A F2A

F2A

F2A

F2A

EM1

F2A

F2A

F2A Storage

1116A

Stair #2 S-2

4" 3'

4" 8' - 6"

F2A

F2A

NEW ROOF OPENING

AFF

ACT 1

8' - 6"

AFF

ACT 1

8' - 6"

AFF

ACT 2

8' - 6"

AFF

ACT 1

8' - 6"

AFF

ACT 1

8' - 0"

AFF

ACT 1

8' - 6"

5' - 7 3/8"

7'

/8

2'

/4

AFF

ACT 1

8' - 6"

AFF

ACT 1

8' - 0"

AFF

ACT 1

8' - 0" REINSTALL EXISTING LIGHT FIXTURE

REINSTALL EXISTING LIGHT

FIXTURES

REINSTALL EXISTING LIGHT FIXTURES

X

X

X

X

X

X

Corridor C1-15

Dispensary

Elec.

Corridor C1-14

Diagnostic

Marco

RCP NOTES

A. SEE CEILING TYPES FOR LOCATION OF EXISTING GRID AND

TRIM TO REMAIN

B. ROOM LIGHTS ARE TO BE REPLACED. SEE ELECTRICAL

SHEETS FOR FIXTURE INFORMATION.

C. REINSTALL THE FOLLOWING (BUT NOT LIMITED TO) CEILING

MOUNTED DEVICES, ITEMS, & FIXTURES IN THEIR PREVIOUS

LOCATION:

a. SMOKE & HEAT DETECTORS

b. CAMERAS

c. WI-FI ANTENNAS

d. SPEAKERS

e. MIRRORS

f. EMERGENCY LIGHTS

g. NURSE CALL LIGHTS

h. SIGNS

i. DIFFUSERS AND GRILLES

j. VISUAL FIRE ALARMS

k. ARTWORK

l. SPRINKLER HEAD TRIM RINGS

m. CURTAIN TRACKS

n. MED GAS LINE ESCUTCHEONS

o. CEILING MOUNTED EXAM LIGHTS

D. GYPSUM BOARD SOFFITS & CEILINGS: REPAIR ANY DAMAGE

AS A RESULT OF ADJACENT GENERAL DEMOLITION OR

CONSTRUCTION WORK UNDER THIS CONTRACT.

E. PRESERVE AND PROTECT EXISTING CEILING GRID AND TRIM

IN INDICATED LOCATIONS.

F2A 2X2 LED TROFFER LIGHT

F1A 4' LED STRIP SUSPENDED

NEW CONSTRUCTION

EXISTING CONSTRUCTION TO REMAIN

Room name

KEYNOTEX

ROOM NAME/NUMBER

0X

CENTERLINE

EC1: EXPOSED CONSTRUCTION

RCP SYMBOLS LEGEND

NEW WORK

F1A

F3

NEW COLUMN

GRID LINE

EXISTING COLUMN

GRID LINE

LED EXIT SIGN

LED EMERGENCY LIGHT W/90 BATTERY

BACKUP

EM1

EX1

LIGHTING

CEILING TYPES

CEILING TYPE &

CEILING ELEVATION8'-0" AFF

ACT1

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

ACT 2: NEW 2X2 LAY-IN

ACOUSTICAL CEILING TILE WITH

NEW GRID AND EDGE TRIM.

ABUSE RESISTANT TILE

GBX: EXISTING GYPSUM BOARD

CEILING OR SOFFIT.

F2A

F3 4" RECESSED CAN DOWNLIGHT,

WET LOCATION TYPE

F7 WALL MOUNTED LED STRIP

LIGHT, WET LOCATION TYPE

F7

ACT 1: NEW 2X2 LAY-IN

ACOUSTICAL CEILING TILE WITH

NEW GRID AND EDGE TRIM

EXISTING 2X2 CEILING SYSTEM

TO REMAIN

EXISTING 2X2 LED TROFFER LIGHT

TO REMAIN

EXISTING 2X4 LED TROFFER LIGHT

TO REMAIN

EXISTING 2X2 LED TROFFER LIGHT

TO BE REINSTALLED

EXISTING 2X4 LED TROFFER LIGHT

TO BE REINSTALLED

EXISTING CAN LIGHT

TO REMAIN

X

X

EXISTING CAN LIGHT

TO BE REINSTALLED

X

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :1

P

M

AC 101

REFLECTED CEILING ENLARGED

PLAN FIRST FLOOR LEVEL

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/4" = 1'-0"

FIRST FLOOR LEVEL REFLECTED CEILING PLAN

CEILING SCHEDULE

TAG

MANUFACTURER

(BASIS OF DESIGN) DESCRIPTION COMMENTS

ACT 1 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM NEW TILE, GRID, & TRIM: USG 'MARS' SERIES

ACT 2 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM NEW TILE, GRID, & TRIM - ABUSE RESISTANT TILE. USG

'FROST' SERIES

GB1 VARIES GYPSUM BOARD CEILING AND SOFFITS, PAINT P4

GBX VARIES EXISTING TO REMAIN PATCH AND REPAIR DAMAGE AS NEEDED

0 2' 4' 8'

AREA OF

WORK

Revisions Date

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

BASEMENT LEVEL

601' - 8 1/2"

ROOF NORTH

628' - 10 1/2"

FIRST FLOOR

LEVEL

616' - 2 1/2"

1x4x6x9x12x13x14x 3x5x5.8x8x10x 6.1x15x 9.5x 1.2x

AE 304

AE 301

AE 304

AE 303

B/DECK

VESTIBULE

614' - 8 1/2"

ALUMINUM FRAMED WINDOWS WITH

SPANDREL PANELS, INSULATED

EXISTING CBOC BEYOND

NORTH FACADE AT BASEMENT LEVEL:

ADHERED THIN STONE VENEER

RETAINING WALL

NEW NORTH VESTIBULE

C C D D D D

T/NORTH

PARAPET

631' - 6 1/2"

NORTH RETAINING

603' - 3 3/4"

AE 303

GRADE 4

605' - 2 1/2"

AE 402

D D D D

SIGN WITH DAYLIGHT SENSOR

D

2'

8" 4'

8"

2'

8"

B B

2'

8" 4'

8"

2'

8" 3'

B

RETAINING WALL

B2-A

B2-A

B2-A

B2

B2

B2

B2

1/ 2"

TSV

MC MC

MC

TSV TSVTSVTSV

TSV

CS1

CS1 CS1CS1CS1

CONTROL JOINTCONTROL JOINTCONTROL JOINT

CONTROL JOINT

CONTROL JOINT

BASEMENT LEVEL

601' - 8 1/2"

ROOF NORTH

628' - 10 1/2"

FIRST FLOOR

LEVEL

616' - 2 1/2"

Hx Jx Kx

Lx

AB

AE 302

104B

METAL GUARDRAIL,

42" HIGH MINIMUM

RETAINING WALLS

NORTH RETAINING

603' - 3 3/4"

AE 303

NEW NORTH VESTIBULE BEYOND

NEW ROOF ACCESS STAIR

BEYOND

2'

8" 4'

8"

2'

8" 3'

EXISTING EAST WALL OF CBOC

NEW BRICK VENEER AT FIRST FLOOR LEVEL

23' - 8"

P6

DOOR &

FRAME

B2

B2

B2

B2

B2-A

B2-A

B2-A

TSV

MC

CS1

B2

CONTROL JOINT

CONTROL JOINT

BASEMENT LEVEL

601' - 8 1/2"

ROOF NORTH

628' - 10 1/2"

FIRST FLOOR

LEVEL

616' - 2 1/2"

ExGxHxJxKx

Lx

FxA B

AE 304

4'

C

RETAINING WALL

RETAINING WALL

T/NORTH

PARAPET

631' - 6 1/2"

NORTH RETAINING

603' - 3 3/4"

NEW NORTH VESTIBULE

BEYOND

NEW ROOF ACCESS

STAIR BEYOND

A A A

5' - 0"

4' - 0"

4'

3'

8" 2'

8"

4'

8" 2'

8" 2'

8"

4'

8" 2'

EXISTING WEST WALL OF CBOC

B2-A

B2-A

B2-A

B2

B2

B2

B2

TSV

EXISTING ACCENT BANDS

EXISTING BRICK

MC

B2

CS1CS1

CONTROL JOINT

SYMBOLS LEGEND - EXTERIOR ELEVATIONS

KEYNOTEX

0X

CENTERLINE

ANEW COLUMN

GRID LINE

EXISTING COLUMN

GRID LINE

EARTH / BACK FILL

STOREFRONT / WINDOW TAG: SEE SHEET AE 602,

WINDOW & STOREFRONT SCHEDULE & DETAILS

FOR SPECIFIC INFORMATION

DOOR TAG: SEE SHEET AE 601, DOOR

SCHEDULE & DETAILS SHEET FOR SPECIFIC

DOOR INFORMATION

Name Elevation

FLOOR/LEVEL

ELEVATION

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

P3

FINISH TAG: SEE SHEET AI 601, FINISH

PLANS & FINISH SCHEDULE DETAILED

FINISHES INFORMATION

B2 EXTERIOR FINISH TAG

THIN STONE VENEER (TSV)

BRICK VENEER, RUNNING

BOND

BRICK VENEER, STACKED

BOND

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :1

P

M

AE 201

ELEVATIONS

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/4" = 1'-0"

1 NORTH ELEVATION

1/4" = 1'-0"

EAST ELEVATION

1/4" = 1'-0"

WEST ELEVATION

WINDOW & STOREFRONT SCHEDULE

TAG DESCRIPTION MANUFACTURER (BASIS OF DESIGN) COMMENTS

A WINDOW KAWNEER (451UT) THERMALLY BROKEN ALUMINUM FRAME WITH INSULATED GLAZING UNITS W/ SECURITY LAMINATED GLASS

B WINDOW KAWNEER (451UT) THERMALLY BROKEN ALUMINUM FRAME WITH INSULATED GLAZING UNITS W/ SECURITY LAMINATED GLASS

C WINDOW KAWNEER (451UT) THERMALLY BROKEN ALUMINUM FRAME WITH INSULATED GLAZING UNITS W/ SECURITY LAMINATED GLASS

D WINDOW KAWNEER (451UT) THERMALLY BROKEN ALUMINUM FRAME WITH INSULATED SPANDREL PANELS

S1 STOREFRONT KAWNEER (451UT) THERMALLY BROKEN ALUMINUM FRAME WITH INSULATED GLAZING UNITS W/ SECURITY LAMINATED GLASS

S2 STOREFRONT KAWNEER (451UT) THERMALLY BROKEN ALUMINUM FRAME WITH INSULATED GLAZING UNITS W/ SECURITY LAMINATED GLASS

S3 STOREFRONT KAWNEER (451UT) THERMALLY BROKEN ALUMINUM FRAME WITH INSULATED GLAZING UNITS W/ SECURITY LAMINATED GLASS

0 2' 4' 8'

0 2' 4' 8' 0 2' 4' 8'

XEXTERIOR FINISHES

TAG KEYNOTE

B2 THIN BRICK, STANDARD, RUNNING BOND

B2-A THIN BRICK, STANDARD - ACCENT, STACKED BOND

CS1 CAST STONE - TRIM

MC PREFINISHED METAL COPING, COLOR TO MATCH EXISTING CBOC COPING

TSV THIN STONE VENEER

MC

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

FIRST FLOOR

LEVEL

616' - 2 1/2"

12x13x

AE 301

22' - 5 1/2"

AE 306

B/DECK

VESTIBULE

614' - 8 1/2"

AE 306

2' - 0" 18' - 6" 2' - 0"

9'

1'

NORTH RETAINING

603' - 3 3/4"

AE 303

5'

0"

2'

S1 S1

4"4"

S3

TSV

TSV

MC

BASEMENT LEVEL

601' - 8 1/2"

FIRST FLOOR

LEVEL

616' - 2 1/2"

AB

8'

2'

3' - 6"

AE 305

AE 305

B/DECK

VESTIBULE

614' - 8 1/2"

NORTH RETAINING

603' - 3 3/4"

S2

STONE VENEER OVER

METAL STUD FRAMING

ALUMINUM FRAMED

STOREFRONT

PREFINISHED SCUPPER &

DOWNSPOUT

PREFABRICATED METAL FRAMED

CANOPY, SUSPENDED

4"

4"

TSV

MC

5'

/8

TSV

APPLIED DIRECTLY

TO CONCRETE

FOUNDATION

TSV

BASEMENT LEVEL

601' - 8 1/2"

FIRST FLOOR

LEVEL

616' - 2 1/2"

A B

8'

2'

3' - 6"

STONE VENEER OVER

METAL STUD FRAMING

ALUMINUM FRAMED

STOREFRONT

PREFINISHED SCUPPER &

DOWNSPOUT

B/DECK

VESTIBULE

614' - 8 1/2"

AE 306

NORTH RETAINING

603' - 3 3/4"

S2

AE 301

PREFABRICATED METAL FRAMED

CANOPY, SUSPENDED

4 "

TSV

TSV

MC

TSV

3'

3/ 4"

APPLIED DIRECTLY

TO CONCRETE

FOUNDATION

SYMBOLS LEGEND - EXTERIOR ELEVATIONS

KEYNOTEX

0X

CENTERLINE

ANEW COLUMN

GRID LINE

EXISTING COLUMN

GRID LINE

EARTH / BACK FILL

STOREFRONT / WINDOW TAG: SEE SHEET AE 602,

WINDOW & STOREFRONT SCHEDULE & DETAILS

FOR SPECIFIC INFORMATION

DOOR TAG: SEE SHEET AE 601, DOOR

SCHEDULE & DETAILS SHEET FOR SPECIFIC

DOOR INFORMATION

Name Elevation

FLOOR/LEVEL

ELEVATION

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

P3

FINISH TAG: SEE SHEET AI 601, FINISH

PLANS & FINISH SCHEDULE DETAILED

FINISHES INFORMATION

B2 EXTERIOR FINISH TAG

THIN STONE VENEER (TSV)

BRICK VENEER, RUNNING

BOND

BRICK VENEER, STACKED

BOND

ROOF NORTH

628' - 10 1/2"

FIRST FLOOR

LEVEL

616' - 2 1/2"

15x

EXIST. T.O.P.

631' - 6 1/4"

3'

8" 2'

8"

4'

8" 2'

B2

B2

B2

B2

B2-A

B2-A

B2-A

MC

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :1

P

M

AE 202

ELEVATIONS

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/2" = 1'-0"

3 DETAIL NORTH ELEVATION - NEW NORTH VESTIBULE

1/2" = 1'-0"

2 DETAIL EAST ELEVATION - NEW NORTH VESTIBULE

1/2" = 1'-0"

4 DETAIL WEST ELEVATION - NEW NORTH VESTIBULE

0 1' 2' 4' 0 1' 2' 4' 0 1' 2' 4'

1/2" = 1'-0"

1 SOUTH ELEVATION - NEW NORTHEAST VESTIBULE 0 1' 2' 4'

EXTERIOR FINISHES

TAG KEYNOTE

B2 THIN BRICK, STANDARD, RUNNING BOND

B2-A THIN BRICK, STANDARD - ACCENT, STACKED BOND

CS1 CAST STONE - TRIM

MC PREFINISHED METAL COPING, COLOR TO MATCH EXISTING CBOC COPING

TSV THIN STONE VENEER

B2

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

New North Vestibule

P1

P1

P1

CT1

CT1

S1S1

S3

BASEMENT LEVEL

601' - 8 1/2"

New North Vestibule

S2

CT1

P1

P1

CG

BASEMENT LEVEL

601' - 8 1/2"

New North Vestibule

001B 001A

P1

CT1

CT1CT1

P3P3

"CG

CG

C A

R D

R E

A D

E R

C A

R D

R E

A D

E R

" BASEMENT LEVEL

601' - 8 1/2"

New North Vestibule

S2

P1

CT1

CG

BASEMENT LEVEL

601' - 8 1/2"

Lobby

001B

CT1

CT1

P1

P3

BASEMENT LEVEL

601' - 8 1/2"

Lobby

P1

CT1

CT1 ELEVATOR DOOR

& FRAME

M A

X

CALL BUTTON

M A

X

LANTERN

M A

X

ADA/ABA COMPLIANT FLOOR

DESIGNATION SIGN

MOUNTED ON RIGHT JAMB FACE

BASEMENT LEVEL

601' - 8 1/2"

Lobby

CT1CT1

P1

P3

BASEMENT LEVEL

601' - 8 1/2"

Lobby

P1

CT1

SYMBOLS LEGEND

INTERIOR ELEVATIONS

Room name

KEYNOTEX

ROOM NAME/NUMBER

0X

CENTERLINE

Name Elevation

FLOOR/LEVEL ELEVATION

NEW COLUMN

GRID LINE

EXISTING COLUMN

GRID LINE

P3

FINISH TAG: SEE SHEET AI 601, FINISH

PLANS & FINISH SCHEDULE DETAILED

FINISHES INFORMATION

1i

STOREFRONT / WINDOW TAG: SEE SHEET

AE 602 WINDOW & STOREFRONT SCHEDULE

& DETAILS FOR SPECIFIC INFORMATION

DOOR TAG: SEE SHEET AE 601, DOOR

SCHEDULE & DETAILS SHEET FOR SPECIFIC

DOOR INFORMATION

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:2 :3

P

M

AE 205

INTERIOR ELEVATIONS -

BASEMENT LEVEL

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/2" = 1'-0"

1 NORTH INTERIOR ELEVATION - NEW NORTH VESTIBULE

1/2" = 1'-0"

2 EAST INTERIOR ELEVATION - NEW NORTH VESTIBULE

1/2" = 1'-0"

3 SOUTH INTERIOR ELEVATION - NEW NORTH VESTIBULE

1/2" = 1'-0"

4 WEST INTERIOR ELEVATION - NEW NORTH VESTIBULE

1/2" = 1'-0"

5 NORTH INTERIOR ELEVATION - ELEVATOR LOBBY 002

1/2" = 1'-0"

6 EAST INTERIOR ELEVATION - ELEVATOR LOBBY 002

1/2" = 1'-0"

7 SOUTH INTERIOR ELEVATION - ELEVATOR LOBBY 002

1/2" = 1'-0"

8 WEST INTERIOR ELEVATION - ELEVATOR LOBBY 002

0 1' 2' 4' 0 1' 2' 4'

0 1' 2' 4' 0 1' 2' 4'

0 1' 2' 4' 0 1' 2' 4' 0 1' 2' 4' 0 1' 2' 4'

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

Kx

AE 304

P1

P1

SS1

SS1

WB2

4"

WB2EXISTING WALL BASE (TO REMAIN)

A A A

CEILING POCKET CEILING POCKET

9'

H E

IG

H

T O

F C

E

IL

IN

G

P O

C K

E T

6" 8'

H

E

IG

H T

O F

M A

IN

R

O O

M C

E

IL

IN

G

8'

H E

IG

H

T O

F M

A

IN

R O

O M

C E

IL

IN

G

6" 8'

H

E

IG

H T

O F

M A

IN

R

O O

M C

E

IL

IN

G

9'

H E

IG

H

T O

F C

E

IL

IN

G

P O

C K

E T

8'

H E

IG

H

T O

F M

A

IN

R O

O M

C E

IL

IN

G

BASEMENT LEVEL

601' - 8 1/2"

WB2

4"

SS1

P2

CEILING

POCKET

9'

H E

IG

H

T O

F C

E

IL

IN

G

P O

C K

E T

1'

8'

H E

IG

H

T O

F M

A

IN

R O

O M

C E

IL

IN

G

BASEMENT LEVEL

601' - 8 1/2"

P2

SS1

WB2

4"

9'

H E

IG

H

T O

F C

E

IL

IN

G

P O

C K

E T

1'

8'

H E

IG

H

T O

F M

A

IN

R O

O M

C E

IL

IN

G

CEILING

POCKET

BASEMENT LEVEL

601' - 8 1/2"

AE 304

WB2

4"

SS1

P2

9'

H E

IG

H

T O

F C

E

IL

IN

G

P O

C K

E T

1'

8'

H E

IG

H

T O

F M

A

IN

R O

O M

C E

IL

IN

G

CEILING

POCKET

Chief Medical Director

B013

Clinical Nurse Manager

B014

A.O.

B015

Home Based Primary Care

B002

SYMBOLS LEGEND

INTERIOR ELEVATIONS

Room name

KEYNOTEX

ROOM NAME/NUMBER

0X

CENTERLINE

Name Elevation

FLOOR/LEVEL ELEVATION

NEW COLUMN

GRID LINE

EXISTING COLUMN

GRID LINE

P3

FINISH TAG: SEE SHEET AI 601, FINISH

PLANS & FINISH SCHEDULE DETAILED

FINISHES INFORMATION

1i

STOREFRONT / WINDOW TAG: SEE SHEET

AE 602 WINDOW & STOREFRONT SCHEDULE

& DETAILS FOR SPECIFIC INFORMATION

DOOR TAG: SEE SHEET AE 601, DOOR

SCHEDULE & DETAILS SHEET FOR SPECIFIC

DOOR INFORMATION

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:2 :4

P

M

AE 206

INTERIOR ELEVATIONS -

BASEMENT LEVEL

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/2" = 1'-0"

1 WEST INTERIOR ELEVATION-HOME BASED PRIMARY CARE ROOM B002

0 1' 2' 4'

1/2" = 1'-0"

NORTH INTERIOR ELEVATION - CHEIF MEDICAL DIRECTOR ROOM B013

1/2" = 1'-0"

NORTH INTERIOR ELEVATION - CLINICAL NURSE MANAGER ROOM B014

1/2" = 1'-0"

NORTH INTERIOR ELEVATION - A.O. ROOM B015 0 1' 2' 4' 0 1' 2' 4' 0 1' 2' 4'

Revisions Date

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

FIRST FLOOR

LEVEL

616' - 2 1/2"

Corridor C1-15A

Alcove 102A

P3

P1

WB1

WB1WB1

NEW WORKEXISTING CBOC

CG

FIRST FLOOR

LEVEL

616' - 2 1/2"

Corridor C1-15A

104A

Alcove 102A

C1-15

WB1WB1WB1

P1P1

P3 CGCG

FIRST FLOOR

LEVEL

616' - 2 1/2"

Corridor C1-15A

C1-15

P3 DOOR FRAME

ONLY

P1P1

WB1

WB1

NEW WORK EXISTING CBOC

CG CG

FIRST FLOOR

LEVEL

616' - 2 1/2"

Alcove 102A

Corridor C1-15A

OPEN TO

BEYONDC1-15

WB1 WB1WB1WB1

P1P1 P1

CG

CG

FIRST FLOOR

LEVEL

616' - 2 1/2"

Storage 1116A

P1

WB1

FIRST FLOOR

LEVEL

616' - 2 1/2"

Storage 1116A

WB1

P1

FIRST FLOOR

LEVEL

616' - 2 1/2"

Storage 1116A

P1

WB1

FIRST FLOOR

LEVEL

616' - 2 1/2"

Storage 1116A

1116A

WB1WB1

P1

P3

SYMBOLS LEGEND

INTERIOR ELEVATIONS

Room name

KEYNOTEX

ROOM NAME/NUMBER

0X

CENTERLINE

Name Elevation

FLOOR/LEVEL ELEVATION

NEW COLUMN

GRID LINE

EXISTING COLUMN

GRID LINE

P3

FINISH TAG: SEE SHEET AI 601, FINISH

PLANS & FINISH SCHEDULE DETAILED

FINISHES INFORMATION

1i

STOREFRONT / WINDOW TAG: SEE SHEET

AE 602 WINDOW & STOREFRONT SCHEDULE

& DETAILS FOR SPECIFIC INFORMATION

DOOR TAG: SEE SHEET AE 601, DOOR

SCHEDULE & DETAILS SHEET FOR SPECIFIC

DOOR INFORMATION

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:2 :4

P

M

AE 207

INTERIOR ELEVATIONS - FIRST

FLOOR LEVEL

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/2" = 1'-0"

1 NORTH INTERIOR ELEVATION - CORRIDOR C1-15A & ALCOVE 102A

1/2" = 1'-0"

2 EAST INTERIOR ELEVATION - ALCOVE 102A & CORRIDOR C1-15A

1/2" = 1'-0"

SOUTH INTERIOR ELEVATION - CORRIDOR C1-15A

1/2" = 1'-0"

WEST INTERIOR ELEVATION - CORRIDOR C1-15A & ALCOVE 102A

0 1' 2' 4' 0 1' 2' 4'

0 1' 2' 4' 0 1' 2' 4'

1/2" = 1'-0"

5 NORTH INTERIOR ELEVATION - STORAGE 1116A

1/2" = 1'-0"

6 EAST INTERIOR ELEVATION - STORAGE 1116A

1/2" = 1'-0"

7 SOUTH INTERIOR ELEVATION - STORAGE 1116A

1/2" = 1'-0"

8 WEST INTERIOR ELEVATION - STORAGE 1116A

0 1' 2' 4' 0 1' 2' 4' 0 1' 2' 4' 0 1' 2' 4'

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

FIRST FLOOR

LEVEL

616' - 2 1/2"

Lobby

P1

WB1

SS1

C

FIRST FLOOR

LEVEL

616' - 2 1/2"

Lobby

ELEVATOR DOOR

& FRAME

P1

WB1

WB1

CALL BUTTON

LANTERN

ADA/ABA COMPLIANT FLOOR

DESIGNATION SIGN

MOUNTED ON LEFT JAMB FACE

M A

X

M A

X

M A

X

FIRST FLOOR

LEVEL

616' - 2 1/2"

Lobby

WB1WB1

P3

DOOR FRAME

ONLY

P1

FIRST FLOOR

LEVEL

616' - 2 1/2"

Lobby

" P1

WB1

FIRST FLOOR

LEVEL

616' - 2 1/2"

Office

C

WB2

SS1

P2

FIRST FLOOR

LEVEL

616' - 2 1/2"

Office

P1

WB2

FIRST FLOOR

LEVEL

616' - 2 1/2"

Office

WB2

P1 P3 DOOR FRAME

ONLY

FIRST FLOOR

LEVEL

616' - 2 1/2"

Office

P1

WB2

FIRST FLOOR

LEVEL

616' - 2 1/2"

Vestibule

" P1

WB1

FIRST FLOOR

LEVEL

616' - 2 1/2"

Vestibule

104B

WB1WB1

P1

FIRST FLOOR

LEVEL

616' - 2 1/2"

Vestibule

P1

WB1

FIRST FLOOR

LEVEL

616' - 2 1/2"

Vestibule

104A8

WB1WB1

P1

P3

SYMBOLS LEGEND

INTERIOR ELEVATIONS

Room name

KEYNOTEX

ROOM NAME/NUMBER

0X

CENTERLINE

Name Elevation

FLOOR/LEVEL ELEVATION

NEW COLUMN

GRID LINE

EXISTING COLUMN

GRID LINE

P3

FINISH TAG: SEE SHEET AI 601, FINISH

PLANS & FINISH SCHEDULE DETAILED

FINISHES INFORMATION

1i

STOREFRONT / WINDOW TAG: SEE SHEET

AE 602 WINDOW & STOREFRONT SCHEDULE

& DETAILS FOR SPECIFIC INFORMATION

DOOR TAG: SEE SHEET AE 601, DOOR

SCHEDULE & DETAILS SHEET FOR SPECIFIC

DOOR INFORMATION

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:2 :5

P

M

AE 208

INTERIOR ELEVATIONS - FIRST

FLOOR LEVEL

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/2" = 1'-0"

1 NORTH INTERIOR ELEVATION - ELEVATOR LOBBY 102

1/2" = 1'-0"

2 EAST INTERIOR ELEVATION - ELEVATOR LOBBY 102

1/2" = 1'-0"

3 SOUTH INTERIOR ELEVATION - ELEVATOR LOBBY 102

1/2" = 1'-0"

4 WEST INTERIOR ELEVATION - ELEVATOR LOBBY 102

1/2" = 1'-0"

NORTH INTERIOR ELEVATION - OFFICE 103

1/2" = 1'-0"

EAST INTERIOR ELEVATION - OFFICE 103

1/2" = 1'-0"

SOUTH INTERIOR ELEVATION - OFFICE 103

1/2" = 1'-0"

WEST INTERIOR ELEVATION - OFFICE 103

1/2" = 1'-0"

9 NORTH INTERIOR ELEVATION - VESTIBULE 104

1/2" = 1'-0"

10 EAST INTERIOR ELEVATION - VESTIBULE 104

1/2" = 1'-0"

11 SOUTH INTERIOR ELEVATION - VESTIBULE 104

1/2" = 1'-0"

12 WEST INTERIOR ELEVATION - VESTIBULE 104

0 1' 2' 4' 0 1' 2' 4' 0 1' 2' 4' 0 1' 2' 4'

0 1' 2' 4' 0 1' 2' 4' 0 1' 2' 4' 0 1' 2' 4'

0 1' 2' 4' 0 1' 2' 4' 0 1' 2' 4' 0 1' 2' 4'

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

ROOF NORTH

628' - 10 1/2"

FIRST FLOOR

LEVEL

616' - 2 1/2"

JxKxLx

EXIST. T.O.P.

631' - 6 1/4"

A

New North Vestibule

B

AE 302

ELEVATOR PIT

596' - 8 1/2"

Lobby

B/DECK

VESTIBULE

614' - 8 1/2"

Lobby

S2

Engineering Space

Corridor C1-15A

104A

AE 301

ALUMINUM STOREFRONT SYSTEM

THERMALLY BROKEN, WITH

INSULATED GLAZING UNITS WITH

LAMINATED SECURITY GLASS

ALUMINUM FRAMED, AUTOMATIC

POWER OPERATED BI-FOLD

DOOR, WITH INSULATED GLAZING

UNITS WITH LAMINATED SECURITY

GLASS

PREFABRICATED METAL FRAMED

CANOPY, SUSPENDED

8" CMU WALL

NEW

EXISTING

CBOC

B2

MC

MC

TSV

AE 502

SYMBOLS LEGEND SECTIONS

EXISTING CONSTRUCTION TO REMAIN

Room name

KEYNOTEX

ROOM NAME/NUMBER

0X

CENTERLINE

1i PARTITION TAG

Name Elevation

FLOOR/LEVEL ELEVATION

1-HOUR RATED CONSTRUCTION

2-HOUR RATED CONSTRUCTION

NEW COLUMN

GRID LINE

EXISTING COLUMN

GRID LINE

DOOR TAG - SEE SHEET

AE 601 DOOR SCHEDULE

FOR MORE INFORMATION

SPOT FLOOR

ELEVATION

A

WINDOW/STOREFRONT

TAG

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

MC EXTERIOR FINISHES KEYNOTE

BASEMENT LEVEL

601' - 8 1/2"

ROOF NORTH

628' - 10 1/2"

FIRST FLOOR

LEVEL

616' - 2 1/2"

EXIST. T.O.P.

631' - 6 1/4"

AE 301

ELEVATOR PIT

596' - 8 1/2"

B/DECK

VESTIBULE

614' - 8 1/2"

NORTH RETAINING

603' - 3 3/4"

New North

Vestibule

1/4" / 1'-0"1/4" / 1'-0"

001B 001A

NORTH WALL BEYOND

THIN STONE VENEER

APPLIED DIRECTLY TO

FOUNDATION WALL

FLASHING

SPRAY-APPLIED

FIRE PROOFING,

2-HOUR, TYPICAL

TSV

MCMC

TSV

TSV

THIN STONE VENEER

APPLIED DIRECTLY TO

FOUNDATION WALL

TSV

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :2

P

M

AE 301

BUILDING SECTIONS

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

3/8" = 1'-0"

1 NORTH-SOUTH SECTION AT NEW NORTH VESTIBULE

0 2' 4' 8'

3/8" = 1'-0"

2 SECTION AT NORTH VESTIBULE EAST TO WEST

0 2' 4' 8'

EXTERIOR FINISHES

TAG KEYNOTE

B2 THIN BRICK, STANDARD, RUNNING BOND

B2-A THIN BRICK, STANDARD - ACCENT, STACKED BOND

CS1 CAST STONE - TRIM

MC PREFINISHED METAL COPING, COLOR TO MATCH EXISTING CBOC COPING

TSV THIN STONE VENEER

MC

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

ROOF NORTH

628' - 10 1/2"

FIRST FLOOR

LEVEL

616' - 2 1/2"

13x 14x 15z

EXIST. T.O.P.

631' - 6 1/4"

AE 301

ELEVATOR PIT

596' - 8 1/2"

Elevator E-2

Lobby

Lobby

9'

/4

3'

HOIST BEAM

OVERRIDE SPACE

ELEVATOR PIT:

PROVIDE ACCESS LADDER,

SUMP, SERVICE LIGHT

NEW LAY-IN ACOUSTICAL

TILE CEILING, 2x2

NEW LAY-IN ACOUSTICAL

TILE CEILING, 2x2

EXISTING FOUNDATION WALL

EXISTING STAIR S-2

NEW MRL ELEVATOR

2' - 4 3/4"

1' - 0"

Office

Lobby

Engineering Space

Mach. Room 003A

003A

C M

U

IN

F

IL

L A

T E

X

IS

T

IN

G O

P E

N

IN

G

7'

G R

A D

E V

A R

IE

S

2'

4"

7'

7'

8" CMU WALL 8" CMU INFILL AT

EXISTING OPENING

EXISTING FLOOR SLAB

EXISTING FOOTING

NEW 5" CONCRETE SLAB-ON-GRADECOMPACTED GRANULAR

FILL, 4" MINIMUM DEPTH

6 MIL. VAPOR BARRIER,

TURN UP AT SLAB EDGES

5" CONCRETE SLAB-ON-GRADE

1/2" COMPRESSIBLE FILLER,

CONTINUOUS

ACT2

ACT2

NEW LAY-IN ACOUSTICAL

TILE CEILING, 2x2 IN

EXISTING STAIR #2

ACT2

NEW LAY-IN ACOUSTICAL

TILE CEILING, 2x2

EXISTING CMU WALL

CONCRETE & METAL

FLOOR SYSTEM

EXISTING PARAPET

NEW TPO MEMBRANE ROOF

SYSTEM OVER TAPERED

INSULATION

ELEVATOR

CAB

PARAPET BEYOND

MC

B2

CS1

TSV

MC MC

ACT2

SPRAY-APPLIED FIRE PROOFING,

TYPICAL FOR ALL NEW STEEL BEAMS, 2-HOUR

SPRAY-APPLIED FIRE PROOFING,

2-HOUR

SPRAY APPLIED FIRE PROOFING

ELEVATOR ROOF DECK & BEAM.

2-HOUR

SYMBOLS LEGEND SECTIONS

EXISTING CONSTRUCTION TO REMAIN

Room name

KEYNOTEX

ROOM NAME/NUMBER

0X

CENTERLINE

1i PARTITION TAG

Name Elevation

FLOOR/LEVEL ELEVATION

1-HOUR RATED CONSTRUCTION

2-HOUR RATED CONSTRUCTION

NEW COLUMN

GRID LINE

EXISTING COLUMN

GRID LINE

DOOR TAG - SEE SHEET

AE 601 DOOR SCHEDULE

FOR MORE INFORMATION

SPOT FLOOR

ELEVATION

A

WINDOW/STOREFRONT

TAG

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

MC EXTERIOR FINISHES KEYNOTE

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :2

P

M

AE 302

BUILDING SECTIONS

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

3/8" = 1'-0"

EAST-WEST SECTION AT NEW ELEVATOR

0 1' 2' 4'

ELEVATOR (BASIS OF DESIGN) INFORMATION:

BASIS OF DESIGN: OTIS 'HYDROFIT' MACHINE-ROOMLESS (MRL) HYDRAULIC ELEVATOR, PASSENGER TYPE.

CAPACITY: 3,500 LBS

CAB SIZE: 6'-5 1/2" WIDE x 5'-6" DEEP

SPEED: 100 FPM

STOPS: 2

PIT DEPTH: 5'-0"

ELEVATOR EQUIPMENT/MACHINERY ACCESS: LOCATED IN MACHINE ROOM 003A, ACCESSED THROUGH

(NEW) STORAGE 003.

EXTERIOR FINISHES

TAG KEYNOTE

B2 THIN BRICK, STANDARD, RUNNING BOND

B2-A THIN BRICK, STANDARD - ACCENT, STACKED BOND

CS1 CAST STONE - TRIM

MC PREFINISHED METAL COPING, COLOR TO MATCH EXISTING CBOC COPING

TSV THIN STONE VENEER

MC

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

AE 100 - BASEMENT LEVEL PLAN NORTH
AE 101 - FIRST FLOOR PLAN NORTH
AE 102N - ROOF PLAN - NORTH PORTION
AE 102S - ROOF PLAN - SOUTH PORTION
AC 100 - REFLECTED CEILING ENLARGED PLANS-BASEMENT LEVEL
AC 101 - REFLECTED CEILING ENLARGED PLAN FIRST FLOOR LEVEL
AE 201 - ELEVATIONS
AE 202 - ELEVATIONS
AE 205 - INTERIOR ELEVATIONS - BASEMENT LEVEL
AE 206 - INTERIOR ELEVATIONS - BASEMENT LEVEL
AE 207 - INTERIOR ELEVATIONS - FIRST FLOOR LEVEL
AE 208 - INTERIOR ELEVATIONS - FIRST FLOOR LEVEL
AE 301 - BUILDING SECTIONS
AE 302 - BUILDING SECTIONS