Att - 4 -578-371_Joliet_CBOC_Add_3_Part_3_R1.pdf

PDF 17 MB Posted

Attached to
578-371 Expansion of Parking Structure at Joliet CBOC Revised
Solicitation number
36C77624B0009
Issued by

About this file

This document provides details for a federal contract solicitation from the Department of Veterans Affairs Technology Acquisition Center Austin. The solicitation, numbered 36C77624B0009, seeks proposals to expand the parking structure at the Joliet Community Based Outpatient Clinic. Offerors must provide construction services to add three additional levels to the existing parking structure. Proposals are due by May 15, 2023, with work expected to be completed within 365 calendar days of the award date. The estimated value of the contract is between $5-10 million. The solicitation is unrestricted and available to all qualified contractors.

View the file

Other files

File Type Posted
36C77624B0009 0011 signed.pdf PDF
Joliet CBOC Parking Expansion - Bid Opening Attendance.pdf PDF
S07 - Abstract of Bids OF 1419 Joliet -S.pdf PDF
Amend 0010 ATT 1 - 578-371 Joliet CBOC Addendum 3 PM R 240502.pdf PDF
36C77624B0009 0010 signed.pdf PDF
36C77624B0009 0009.pdf PDF
Joliet CBOC Technical Questions 1-41 VA Responses Final.pdf PDF
36C77624B0009 0008.pdf PDF
36C77624B0009 0007.pdf PDF
S05 - Joliet CBOC - Technical Questions - Updated 041524.pdf PDF
13974 - Joliet Geotechnical Report.pdf PDF
S05 - Joliet CBOC - Technical Questions 1-41 VA Responses.pdf PDF
26 24 13 Distribution Switchboards.pdf PDF
36C77624B0009 0006.pdf PDF
26 05 73 Overcurrent Protective Device Coordination Study.pdf PDF
26 22 00 Low Voltage Transformers.pdf PDF
13974 - Proposed Parking Addition REV01.pdf PDF
26 24 16 Panelboard.pdf PDF
Pre-bid Site Visit 2 Sign-in Sheet.pdf PDF
36C77624B0009 0005.pdf PDF
36C77624B0009 0004.pdf PDF
36C77624B0009 0003.pdf PDF
Updated - Wage Rates - Will County 2.23.24.pdf PDF
Site Visit 2 Details.pdf PDF
578-371 Pre-bid Site Visit 031824.pdf PDF
36C77624B0009 0002.pdf PDF
36C77624B0009 0001.pdf PDF
ATT 10 - 578-371_Joliet_CBOC_Add_3_Parts_Index.pdf PDF
ATT 9 - 578-371_Joliet_CBOC_Add_3_Part_8.pdf PDF
ATT 8 - 578-371_Joliet_CBOC_Add_3_Part_7.pdf PDF
ATT 12 - Limitations on Subcontracting.pdf PDF
ATT 7 - 578-371_Joliet_CBOC_Add_3_Part_6.pdf PDF
ATT 13 - Wage Rates - Will County 2.23.24.pdf PDF
S02 - 36C77624B0009 - Solicitation - Joliet Parking Expansion.pdf PDF
ATT 1 - Specifications Book.pdf PDF
ATT 5 - 578-371_Joliet_CBOC_Add_3_Part_4.pdf PDF
ATT 3 - 578-371_Joliet_CBOC_Add_3_Part_2.pdf PDF
ATT 6 - 578-371_Joliet_CBOC_Add_3_Part_5.pdf PDF
ATT 11 - 578-371 Construction SOW Final.pdf PDF
ATT 4 - 578-371_Joliet_CBOC_Add_3_Part_3.pdf PDF
ATT 2 - 578-371_Joliet_CBOC_Add_3_Part_1.pdf PDF
ATT 14 - Site Visit Instructions.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

Ex Gx Hx Jx Kx K'x Lx

1x

4x

6x

9x

12x

13x

14x

CxBxAxA1xB1xC1xD1xE1x

3x

5x

5.8x

8x

10x

6.1x

15x

9.5x

1.2x

A

B

2' - 8"

Engineering Space

Elevator E-2

New North Vestibule

Mach. Room 003A

Lobby

C1

C1

C1

C1

BASEMENT LEVEL

UNOCCUPIED DURING

PHASE C1 & C3

C3

C3

C3

C3

Elev. Equip.

B003

Badge B004

Phone B002C

Home Based Primary Care

B002

Stair #2 S-2

Comm.

B005

Reception B001

Women's Restroom

B006

Men's Restroom

B008

HAC

B007

Copy Room B009

Phone B002A

Phone B002B

Phone B017

Phone B016

A.O.

B015

Clinical Nurse Manager

B014

Chief Medical Director

B013 Patient

Education/Group Room

B011

Patient Education/Exercise

B010

Store B012

Corridor C0-2

Corridor C0-3

Corridor C0-4

Corridor C0-1

Mech.

B018

Elec.

B019

Gen Room B020

PAS Call Center

B024

Education Storage

B022

Nutrition Services

B021

Main Conference

Room B023

Mech.

B025

Patient Education/Group

Room B033

Patient Education/Group

Room B032

Patient Ed/Internet

Cafe B031

Corridor C0-6

Corridor C0-8

Corridor C0-7

Staff Lounge B042

Men's Staff Locker

B036

Women's Staff Locker

B034

Mech.

Corridor C0-9

Corridor C0-5

Mech.

B026

Elec.

B029

Elec.

B028

Comm B030

Facility Storage

B041

EMS

B038

Building Operator

B039

FMS

B040

Stair #1 S-1

Corridor C0-1

Elevator

EL-1

Mech.

B018

Patient Education/Exercise

B010

Vending

Cooking Classroom

0023A

PHASE C1 - NORTH WALL, NORTH

VESTIBULE, NE VESTIBULE.

NEW CONSTRUCTION PHASING LEGEND

BASEMENT LEVEL

UNOCCUPIED

PHASE C3 - INTERIOR FIT-OUT

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :3

P

M

GC 007

BASEMENT LEVEL PLAN-NEW

CONSTRUCTION PHASING

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

3/32" = 1'-0"

BASEMENT LEVEL PLAN-NEW CONSTRUCTION PHASING

0 8' 16' 32'

NOTE: SEE SHEET GC 003 'PROPOSED PROJECT SCHEDULE

WITH PHASING' FOR THE SEQUENTIAL RELATIONSHIP OF

EACH PHASE DEPICTED ON THIS PLAN.

Revisions Date

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

ISSUED FOR BID ADDENDUM 1 04/21/2023

ADDENDUM 3 REVIEW 09/22/2023

ADDENDUM 3 ISSUED FOR BID 10/11/2023

C

Ex Gx Hx Jx Kx K'x Lx

1x

4x

6x

9x

12x

13x

14x

CxBxAxA1xB1xC1xD1xE1x

3x

5x

5.8x

8x

10x

6.1x

Fx A.E

15x

9.5x

1.2x

A

B

F

/4

34' - 7 1/4"

Vestibule

Office

Lobby

Elevator E-2

EXISTING BOILER HOUSE

C1

C1

C1

C1

CONSTRUCTION

BARRIER

CONSTRUCTION

BARRIER

TEMPORARY EGRESS

E

C3

C3

FMS

Elevator

EL-1

Stair #2 S-2

Corridor C1-15

Rad Control

Dispensary

Storage 1116A

Diagnostic

Marco

Rad Room

Corridor C1-13

Corridor C1-14

Corridor C1-11

Toilet

Toilet

HAC

Toilet 1112E

Soiled Utility 1112A

Storage 1112B

PM&R

Treatment 1112D

Eye Tech

Visual Fields

Treatment 1112C

Toilet

Toilet 1102A

Eye

Blood Draw 1114D

Eye

Blood Draw 1114C

Draw Analysis

1114E

Toilet 1114F

Blood Draw 1114B

Eye

Eye

1-On-1 Room 1017C

Work Room 1017B

Supervisor Office

1017A

Nurse Triage

Exam 1

Exam 2

Nurse Triage

Women Health Exam

IT

Telemed

Telemed

Telemed

Closet

Telemed

Telemed

Toilet 1043A

Telemed

Telemed 1038Exam 17

Exam 16

PACT 2

PACT 1

Exam 15

Exam 14

Exam 12

Exam 13

Exam 5

Women Health Exam

Toilet

Toilet 1047A

Men's Restroom

Women's Restroom

Treatment Room

Toilet

Treatment Room

CWT

CWT

Security

Wheelchair Storage

Group

Treatment

Treatment Room

Group Treatment

Treatment Room

Treatment Room

Treatment Room

Treatment Room

Soiled Utility

Exam 6

Exam 7

Exam 8

Exam 9

Clean Storage

Exam10

Procedure 1 Shared Gyno

Toilet 1059B

Toilet

Closet 1059A

Procedure 2

Exam 11

Exam 19

Exam 18

PACT

PACT 4

Women Health Exam

Women Health Exam

Corridor C1-3

Telemed

HAC

Stair #1 S-1

Mobile Port Waiting

Toilet 1068A

Toilet 1031A

Pharm. D

Pharm. D

Nutritionist

Teleretinal

Cardio/Pod Shared Office

Soiled Utility

Clean Utility

Social Worker

Shell Space

Corridor C1-10

Podiatry Exam

Podiatry Exam

Tech Work Room

Audiology Exam

Cast Room

Podiatry Exam

Audiology Exam

Oxygen Evaluation

1093PFT Blood Gas

Clean Utility

Soiled Utility

Control

Sound Booth

Control

Sound Booth

Stor.

Corridor C1-12

Corridor C1-9

Corridor

Ambulance Bay C1-36

Corridor C1-5

Corridor C1-5

Corridor C1-7

Corridor C1-6

Corridor C1-6

Corridor C1-4

Corridor C1-8

Corridor C1-1

General Waiting

Corridor C1-2

Photo Alcove

Reception

Equipment Alcove

Nourishment Alcove

Scale Alcove

Meds

1065C

1065B

1065A

Elec. Clos.

1089A

Scale Alcove

PAS

Elec.

1114A

Boiler Plant

PHASE C1 - NORTH WALL, NORTH

VESTIBULE, NE VESTIBULE

NEW CONSTRUCTION PHASING LEGEND

FIRST FLOOR LEVEL

PHASE C3 - INTERIOR FIT-OUT

UNOCCUPIED

1. THE GENERAL CONTRACTOR SHALL PROVIDE

TEMPORARY EXIT SIGNS TO DIRECT THE PUBLIC,

STAFF, AND CONTRACTORS TO AVAILABLE EXITS,

DURING CONSTRUCTION.

2. TEMPORARY EXIT SIGNS SHALL BE LOCATED TO

CLEARLY INDICATE THE AVAILABLE PATHS OF

EGRESS AND LOCATIONS OF AVAILABLE EXITS.

3. EXISTING EXIT SIGNS THAT POINT TO BLOCKED

PATHS OF EGRESS AND EXITS SHALL BE COVERED

TO PREVENT CONFUSION.

TEMPORARY EGRESS

E = TEMPORARY EXIT SIGN.

1. THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY BARRICADE PARTITIONS AS REQUIRED TO ISOLATE CONSTRUCTION AREAS

FROM AREAS TO REMAIN UNDISTURBED, AND SHALL COORDINATE THEIR EXACT LOCATION WITH THE COR. ADDITIONAL TEMPORARY

BARRICADE PARTITIONS OTHER THAN THOSE INDICATED ON THE PLANS SHALL BE REQUIRED AS NECESSARY TO ACCOMPLISH THE

CONSTRUCTION PROCESS, AND WHERE APPLICABLE, TO ISOLATE DIFFERENT PHASES OF THE WORK.

2. TEMPORARY BARRICADE PARTITIONS SHALL BE PROVIDED AROUND ANY AREA OF WORK CONSIDERED TO BE HAZARDOUS OR WHERE

THE SPRINKLER SYSTEM IS RENDERED INEFFECTIVE BY THE REMOVAL OF THE CEILING SYSTEM FOR MORE THAN A WORK SHIFT AT A

TIME.

3. MEANS OF EGRESS SHALL BE MAINTAINED FOR THE PUBLIC, STAFF, AND CONTRACTOR EMPLOYEES AT ALL TIMES.

4. ALL TEMPORARY BARRICADE PARTITIONS SHALL BE DUST PROOF AND SEALED AT ALL JUNCTIONS OF DISSIMILAR MATERIALS USING

GASKETING MATERIAL. ADEQUATE PRECAUTIONS SHALL ALSO BE TAKEN TO PREVENT DUST AND NOXIOUS VAPORS FROM ENTERING THE

RETURN AIR DUCTWORK IN THE AREAS OF CONSTRUCTION.

5. EXISTING WALLS UTILIZED AS PART OF THE CONSTRUCTION BARRIER MUST EXTEND TO THE DECK ABOVE AND ALL PENETRATIONS MUST

BE FIRESTOPPED.

TEMPORARY CONSTRUCTION BARRICADES

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :4

P

M

GC 008

FIRST FLOOR LEVEL PLAN-NEW

CONSTRUCTION PHASING

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

3/32" = 1'-0"

1 FIRST FLOOR LEVEL-NEW CONSTRUCTION PHASING

NOTE: SEE SHEET GC 003 'PROPOSED PROJECT SCHEDULE

WITH PHASING' FOR THE SEQUENTIAL RELATIONSHIP OF

EACH PHASE DEPICTED ON THIS PLAN.

Revisions Date

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

ISSUED FOR BID ADDENDUM 1 04/21/2023

F2

UP

C

Ex

Gx

Gx

Hx

Hx

Jx

Jx

Kx

Kx

K'x

K'x Lx

1x

4x

6x

9x

12x

13x

14x

CxBxAxA1xB1xC1xD1xE1x

3x

5x

5.8x

8x

10x

6.1x

Fx

15x

9.5x

1.2x

A

B

F

128' - 8 3/4"

N E

W N

O R

T H

V E

S T

IB

U

L E

B E

L O

W

C2

EXISTING ROOF OVER STAIR S-1

TO REMAIN

EXISTING ROOF OVER BOILER HOUSE

TO REMAIN

C2

SOUTH PORTION

ROOF LEVEL

NEW ROOF ACCESS

STAIR & ENCLOSURE

C1

C1

C1

C1

NORTH PORTION

ROOF LEVEL

C2

C2

C2

PHASE C1 - NORTH WALL, NORTH

VESTIBULE, NE VESTIBULE,

ROOF ACCESS STAIR & ENCLOSURE

NEW CONSTRUCTION PHASING LEGEND

ROOF LEVEL

PHASE C2 - NEW ROOFING SYSTEM

ENTIRE ROOF

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :5

P

M

GC 009

ROOF LEVEL PLAN-NEW

CONSTRUCTION PHASING

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

3/32" = 1'-0"

ROOF LEVEL PLAN-NEW CONSTRUCTION PHASING

0 8' 16' 32'

NOTE: SEE SHEET GC 003 'PROPOSED PROJECT SCHEDULE

WITH PHASING' FOR THE SEQUENTIAL RELATIONSHIP OF

EACH PHASE DEPICTED ON THIS PLAN.

Revisions Date

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

WALK

CONCRETE

50.00'

AREA

PARKING

ASPHALT

P R O P O S E D

D R A I N A G E

E A S E M E N T

V A

C A

T E

D H

I G

H

VACATED EAGLE

STREETPER DOC. NO.

R2004-124843

W A

L N

U T

S T

R E

E T

A V

E N

U E

W A

L N

U T

S T

R E

E T

EAGLE

STREET

S2-HS

MH: 35

S3-HS

MH: 35

S3-HS

MH: 35

S2-HS

MH: 35

S3-HS

MH: 35

S3-HS

MH: 35

1 0 1 3

1 10

1 2 3 4 5

6 7 8 9

UP

S1

S2

S2

S2

Joliet CBOC

NEW CONSTRUCTION PHASING LEGEND

SITE WORK

PHASE S1 - NEW NORTH PARKING LOT,

RETAINING WALLS, LANDSCAPING,

& SITE LIGHTING

PHASE S2 - SEAL COAT EXISTING PARKING

LOTS, RESTRIPE, & REPLACE EXISTING

LIGHTING

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :0

P

M

GC 010

SITE WORK PLAN - NEW

CONSTRUCTION PHASING

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1" = 30'-0"

SITE WORK PLAN - NEW CONSTRUCTION PHASING

0 60'30'

NOTE: SEE SHEET GC 003 'PROPOSED PROJECT SCHEDULE

WITH PHASING' FOR THE SEQUENTIAL RELATIONSHIP OF

EACH PHASE DEPICTED ON THIS PLAN.

Revisions Date

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

Ex

Gx

Hx

Jx

Kx

K'x

Lx

1x

6x

12x 13x 14x5.8x

8x

10x6.1x 15x9.5x1.2x

SCH REMNANT

JOLIET CBOC

SCH REMNANT

JOLIET CBOC

NEW OPENINGS IN

EXISTING CBOC FOUNDATION

WALL FOR NEW WINDOWS,

TYPICAL OF 6

EXISTING MASONRY WALLS,

REMOVE

EXISTING CAST-IN-PLACE CONCRETE

STRUCTURE, REMOVE

RO

3' - 4 1/2" 11 1/4"

NEW OPENING IN EXISTING

CBOC FOUNDATION WALL

FOR NEW DOOR

EXISTING MASONRY

WALLS, REMOVE

EXISTING RETAINING

WALL TO REMAIN

+/- 13' - 9"

PORTION OF RETAINING WALL

TO BE REMOVED

APPROXIMATE EXTENT OF

SCH DEMOLITION

7'

/2

+/- 155' - 7 3/4"

4'

/4

+/- 84' - 9"

+/- 23' - 4"

601' - 8 1/2"

+/- 50' - 2"

3'

2'

1/ 2"

EXISTING INTERSTITIAL SPACE

BETWEEN SCH & THE CBOC

EXISTING INTERSTITIAL SPACE

BETWEEN SCH & THE CBOC

2'

1/ 2"

2' - 3 1/2"

REMOVE EXISTING WALLS &

STRUCTURE

OF EXISTING NE VESTIBULE

THIS PORTION OF FOUNDATION

WALL TO REMAIN

PORTION OF EXISTING WALL

14' - 4" REMOVE THIS

D1

D1

D1

D1

D2

D2

D2

EXISTING COLUMN, PIER, & FOOTING

TO REMAIN, VERIFY THE LOCATION & ELEVATION OF

THE EXISTING FOOTING

EXISTING COLUMN TO REMAIN

D7

D7

D7 D7

D7

D7

D71

AD 301

AD 301

AD 301

/4

/2

9' - 0"

RO

5' - 4" 5' - 6"

RO

5' - 4" 5' - 10"

RO

5' - 4" 6' - 2"

2'

0"

R O

4'

8'

R O

4'

2'

R O

4'

'-8

Elev. Equip.

B003

Badge B004

Phone B002C

Home Based Primary Care

B002

Stair #2 S-2

Comm.

B005

Reception B001

Women's Restroom

B006

Men's Restroom

B008

HAC

B007

Copy Room B009

Phone B002A

Phone B002B

Phone B017

Phone B016A.O.

B015

Clinical Nurse Manager

B014

Chief Medical Director

B013

Corridor C0-2

Corridor C0-1

Elevator

EL-1

SPECIAL NOTE:

DUE TO THE PROXIMITY OF THE EXISTING SILVER CROSS HOSPITAL (SCH) REMNANT TO THE EXISTING CBOC

STRUCTURE, THE CONTRACTOR SHALL TAKE PRECAUTIONS TO PREVENT DAMAGE, COLLAPSE, OR

WEAKENING OF THE EXISTING CBOC STRUCTURE:

1. DURING DEMOLITION WORK, THE CONTRACTOR SHALL CONDUCT DAILY ON-SITE SURVEYS OF THE

CONDITION OF THE CBOC STRUCTURE TO ASSESS ANY APPARENT DAMAGE TO CBOC STRUCTURE

INCLUDING BUT NOT LIMITED TO: FOUNDATIONS, STRUCTURAL FRAME, AND WALLS.

2. AT COMPLETION OF REMNANT STRUCTURE DEMOLITION WORK, THE CONTRACTOR SHALL, ON A WEEKLY BASIS, CONTINUE ON-SITE SURVEYS OF THE EXISTING WORK AT OR NEAR THE AREAS OF

DEMOLITION TO ASSESS ANY APPARENT DAMAGE TO THE EXISTING CBOC STRUCTURE.

3. PROVIDE TEMPORARY BRACING AND SHORING WITH CONNECTIONS OF SUFFICIENT STRENGTH TO BEAR IMPOSED LOADS, AND TO PROTECT ALL PERSONS AND PROPERTY, AND TO ENSURE PROPER ALIGNMENT. COMPLY WITH ALL STATE, O.S.H.A., VA REQUIREMENTS, AND LOCAL CODES. THE

CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR PROVIDING ADEQUATE BRACING OF

FOUNDATIONS, STRUCTURAL FRAME, AND WALLS DURING DEMOLITION. CONTRACTOR SHALL

ASSUME ALL RESPONSIBILITY FOR DAMAGE DUE TO HIS FAILURE TO TAKE SUCH PRECAUTIONS.

SYMBOLS LEGEND

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

0 EXISTING COLUMN

GRID LINE X

Room name

KEYNOTEX

ROOM NAME/NUMBER

0 NEW COLUMN

GRID LINE

PHOTOGRAPHY TAG (APPROXIMATE POSITION OF

CAMERA & ANGLE)1

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :1

P

M

AD 100

BASEMENT DEMOLITION PLAN

REMNANT STRUCTURE & N.E.

VESTIBULE

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/8" = 1'-0"

1 BASEMENT LEVEL DEMOLITION PLAN

WEST FACADE OF SCH REMNANT STRUCTURE & RETAINING WALL

NORTHWEST CORNER OF SCH REMNANT STRUCTURE

VIEW OF BASEMENT LEVEL OF SCH REMNANT STRUCTURE VIEW OF EXISTING CAST-IN-PLACE STRUCTURE

ARCHITECTURAL DEMOLITION KEYNOTES

KEY KEYNOTE

D1 REMOVE EXISTING WALLS

D2 REMOVE EXISTING STRUCTURAL COLUMNS INCLUDING FOOTINGS

D3 REMOVE DOOR, FRAME, AND HARWARE

D4 REMOVE EXISTING FLOOR FINISHES AND WALL BASE

D5 REMOVE EXISTING CEILINGS, GRID, AND TRIM

D6 REMOVE ANY EXISTING MILLWORK, PROTECT & PRESERVE FOR

REINSTALLATION

D7 REMOVE EXISTING FOOTINGS

D8 REMOVE DOOR & FRAME. SALVAGE EXISTING DOOR HARDWARE INCLUDING

MAGNETIC DOOR HOLD OPENERS FOR REINSTALLATION ON NEW DOOR.

Dn

NOTE: EXISTING SCH REMNANT STRUCTURE TO BE REMOVED IN ITS ENTIRETY INCLUDING FOUNDATIONS.

3 4

0 4' 8' 16'

AREA OF

WORK

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

Hx

Jx

Kx

K'x

Lx

1x 13x 14x5.8x 8x 10x6.1x

Fx

SCH REMNANT

JOLIET CBOC

SCH REMNANT

JOLIET CBOC

APPROXIMATE EXTENT OF

SCH DEMOLITION

REMOVE EXISTING WALLS AT

CBOC NORTHEAST VESTIBULE,

AT NORTH EDGE

EXISTING CAST-IN-PLACE CONCRETE

COLUMNS & BEAMS, CBOC - TYPICAL

EXISTING MASONRY

WALLS - SCH REMNANT

TO BE REMOVED

EXISTING CMU INFILL

EXISTING CMU

INFILL

EXISTING INTERSTITIAL SPACE

BETWEEN SCH & THE CBOC

EXISTING INTERSTITIAL SPACE

BETWEEN SCH & THE CBOC

2'

1/ 2"

2' - 3 1/2"

2'

0"

3'

/2

+/- 41' - 5 3/4"

1'

/4

+/- 84' - 11 1/4"

+/- 33' - 1 3/4"

8'

/2

146' - 11 1/2"

0'

+/- 23' - 4"

0'

+/- 10' - 0 1/2" +/- 13' - 3 1/2"

PORTION OF EXISTING WALL

14' - 6 1/2" REMOVE THIS

DN

REMOVE EXISTING CONCRETE

SLAB ON GRADE

31' - 8"

7'

/4

D1

D1

D2

D2

D2

D3

D3

D3

D3

D2

D1

D1

D1

REMOVE EXISTING DOOR,

FRAME & HARDWARE.

ENLARGE OPENING TO RECEIVE NEW WINDOW

D8

D3

D1

D1

D4

D4

D4

D4

D4

D5

D5

D5

D5

D5

D6

EXISTING SLAB TO BE REMOVED

18' - 5" PORTION OF

AD 301

AD 301 1

AD 301

REMOVE EXISTING

ROOF ACCESS

LADDER

REMOVE PORTION

OF EXISTING

CHAIN LINK FENCING

AT THESE LOCATIONS

REMOVE PORTION OF

EXISTING

CONCRETE WALKWAY

TO ALLOW FOR

INSTALLATION OF

NEW WORK

+/- 21' - 6"

8'

/8

REMOVE EXISTING

FENCING

EXISTING WALL TO REMAIN

EXISTING COLUMN TO REMAIN

REMOVE EXISTING CONCRETE

SLAB ON GRADE

D1

LINE OF SAWCUTTING

LINE OF

SAWCUTTING

R O

5'

AD 1012

REMOVE EXISTING WINDOW FOR TEMPORARY

EGRESS DOOR. PRESERVE WINDOW FOR REINSTALLATION.

EXPAND EXISTING WINDOW OPENING BELOW TO

ACCOMMODATE THE INSTALLATION OF TEMPORARY DOOR

T1

4' -9

/2

FMS

Elevator

EL-1

Stair #2 S-2

Egress Corridor

Exit Vestibule

Storage

Corridor C1-15

Rad Control

Dispensary

Storage 1116A

Diagnostic

Marco

Rad Room

Corridor C1-10

Clean Utility

Soiled Utility

Control

Sound Booth

Control

Sound Booth

Stor.

Elec. Clos.

1089A

Elec.

Corridor C1-14

Corridor C1-15

SPECIAL NOTE:

DUE TO THE PROXIMITY OF THE EXISTING SILVER CROSS HOSPITAL (SCH) REMNANT TO THE EXISTING CBOC

STRUCTURE, THE CONTRACTOR SHALL TAKE PRECAUTIONS TO PREVENT DAMAGE, COLLAPSE, OR

WEAKENING OF THE EXISTING CBOC STRUCTURE:

1. DURING DEMOLITION WORK, THE CONTRACTOR SHALL CONDUCT DAILY ON-SITE SURVEYS OF THE

CONDITION OF THE CBOC STRUCTURE TO ASSESS ANY APPARENT DAMAGE TO CBOC STRUCTURE

INCLUDING BUT NOT LIMITED TO: FOUNDATIONS, STRUCTURAL FRAME, AND WALLS.

2. AT COMPLETION OF REMNANT STRUCTURE DEMOLITION WORK, THE CONTRACTOR SHALL, ON A WEEKLY BASIS, CONTINUE ON-SITE SURVEYS OF THE EXISTING WORK AT OR NEAR THE AREAS OF

DEMOLITION TO ASSESS ANY APPARENT DAMAGE TO THE EXISTING CBOC STRUCTURE.

3. PROVIDE TEMPORARY BRACING AND SHORING WITH CONNECTIONS OF SUFFICIENT STRENGTH TO BEAR IMPOSED LOADS, AND TO PROTECT ALL PERSONS AND PROPERTY, AND TO ENSURE PROPER ALIGNMENT. COMPLY WITH ALL STATE, O.S.H.A., VA REQUIREMENTS, AND LOCAL CODES. THE

CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR PROVIDING ADEQUATE BRACING OF

FOUNDATIONS, STRUCTURAL FRAME, AND WALLS DURING DEMOLITION. CONTRACTOR SHALL

ASSUME ALL RESPONSIBILITY FOR DAMAGE DUE TO HIS FAILURE TO TAKE SUCH PRECAUTIONS.

SYMBOLS LEGEND

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

0 EXISTING COLUMN

GRID LINE X

Room name

KEYNOTEX

ROOM NAME/NUMBER

0 NEW COLUMN

GRID LINE

PHOTOGRAPHY TAG (APPROXIMATE POSITION OF

CAMERA & ANGLE)1

EXISTING NORTHEAST VESTIBULE CONCRETE

SLAB TO BE REMOVED

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

FIRST FLOOR

LEVEL

616' - 2 1/2"

T1

TEMPORARY EGRESS

DOOR

INFILL OPENING WITH METAL

STUD FRAMING, BATT INSULATION

& EXTERIOR GRADE GWB BOTH SIDES.

PAINTED.

DOUBLE STUDS AT EACH JAMB

SEALANT AT ALL EDGES, TYPICAL

EXISTING CBOC

MASONRY WALL

8" DOUBLE STUDS AT HEAD

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :2

P

M

AD 101

FIRST FLOOR DEMOLITION PLAN

REMNANT STRUCTURE & N.E.

VESTIBULE

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/8" = 1'-0"

FIRST FLOOR LEVEL DEMOLITION PLAN

CBOC

SCH REMNANT STRUCTURE

VIEW SOUTHWEST - LOOKING AT NORTHEAST CORNER OF SCH REMNANT STRUCTURE

VIEW INSIDE SCH REMNANT STRUCTURE

VIEW OF EXTERIOR SCH REMNANT - EASTERN PORTION

VIEW OF EXTERIOR SCH REMNANT - WESTERN PORTION

VIEW OF TIE-IN AT SCH REMNANT STRUCTURE AND CBOC

ARCHITECTURAL DEMOLITION KEYNOTES

KEY KEYNOTE

D1 REMOVE EXISTING WALLS

D2 REMOVE EXISTING STRUCTURAL COLUMNS INCLUDING FOOTINGS

D3 REMOVE DOOR, FRAME, AND HARWARE

D4 REMOVE EXISTING FLOOR FINISHES AND WALL BASE

D5 REMOVE EXISTING CEILINGS, GRID, AND TRIM

D6 REMOVE ANY EXISTING MILLWORK, PROTECT & PRESERVE FOR

REINSTALLATION

D7 REMOVE EXISTING FOOTINGS

D8 REMOVE DOOR & FRAME. SALVAGE EXISTING DOOR HARDWARE INCLUDING

MAGNETIC DOOR HOLD OPENERS FOR REINSTALLATION ON NEW DOOR.

NOTE: EXISTING SCH REMNANT STRUCTURE TO BE REMOVED IN ITS ENTIRETY INCLUDING FOUNDATIONS.

Dn

REMOVE PORTION OF

EXISTING CHAIN LINK FENCING

VIEW OF EXISTING NORTH EAST VESTIBULE 6

EXISTING CBOC TO REMAIN

EXISTING NORTHEAST

TO BE REMOVED

EXISTING LIGHT POLE

TO REMAIN

REMOVE EXISTING

FENCING

REMOVE PORTION OF

EXISTING CONCRETE

WALKWAY

0 4' 8' 16'

1/4" = 1'-0"

PARTIAL EAST ELEVATION AT TEMPORARY EGRESS DOOR

NOTE: AT THE COMPLETION OF CONSTRUCTION,

RESTORE ORIGINAL WINDOW AND OPENING.

AREA OF

WORK

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

ISSUED FOR BID ADDENDUM 1 04/21/2023

JxJx

Lx Lx

1x 6x 14x5.8x

Fx

SCH REMNANT

JOLIET CBOC

SCH REMNANT

JOLIET CBOC

EXISTING SILVER CROSS HOSPITAL (SCH)

2ND FLOOR

EXISTING SILVER CROSS HOSPITAL (SCH)

EXISTING INTERSTITIAL SPACE

BELOW - SEE SECTION 1/AD 301

EXISTING INTERSTITIAL SPACE

BELOW - SEE SECTION 1/AD 301

EXISTING WALLS OF SCH,

REMOVE

EXISTING CBOC NE VESTIBULE ROOF

STRUCTURE TIED TO EXISTING

SCH WALLS AT THESE LOCATIONS.

METAL DECK TIE-IN

AT ROOF, REMOVE

BACK TO CBOC ROOF

DECK

APPROXIMATE EXTENT OF

SCH DEMOLITION

METAL DECK TIE-IN

AT ROOF: REMOVE

BACK TO CBOC ROOF

DECK. PREPARE EXISTING

ROOF DECK FOR INSTALLATION

OF NEW PARAPET & ROOFING,

TYPICAL

2'

1/ 2"

2' - 3 1/2"

2'

1/ 2"

+/- 41' - 5 3/4"

3'

/2

+/- 146' - 11 1/2"

0'

/4

+/- 79' - 8 1/4"

EXISTING CBOC ROOF

EXISTING CBOC PARAPET TO REMAIN

EXISTING CBOC

PARAPET

EXISTING CBOC PARAPET

TERMINATES AT SOUTH

WALL OF SCH

EXISTING WALLS BELOW

TO BE REMOVED

EXISTING WALLS BELOW

TO BE REMOVED

EXISTING EDGE OF SCH SOUTH WALL,

METAL DECK TIE-IN IS SUPPORTED BY

CONTINUOUS STEEL ANGLE, REMOVE.

EXISTING WALLS BELOW

R E

M O

V E

T H

IS

P

O R

T

IO

N O

F E

X

IS

T

IN

G P

A R

A P

E T

/4

R

O O

F S

T R

U C

T U

R E

T O

B E

R E

M O

V E

D

6'

P

O R

T

IO

N O

F E

X

IS

T

IN

G R

O O

F

& ROOF STRUCTURE TO BE REMOVED

32' - 1 1/2" PORTION OF EXISTING ROOF

E X

IS

T

IN

G

R O

O F

S

T R

U C

T U

R E

T O

R E

M A

IN

0"

18' - 10 1/4"

EXISTING COLUMN LINE Jx

PORTION OF EXISTING WALL

14' - 6 1/2" REMOVE THIS

TEMPORARILY FOLD, SEAL, AND SECURE

EXISTING ROOF MEMBRANE OVER

EDGE OF EXPOSED CBOC WALL.

TEMPORARILY FOLD, SEAL, AND SECURE

EXISTING ROOF MEMBRANE OVER

EDGE OF EXPOSED CBOC WALL.

SEE DETAIL 2/AD 301

AD 301

AD 301

AD 301

4'

/8

1'

/8

10' - 6 1/8" 8' - 8 3/4"

REMOVE PORTION OF EXISTING

CAST-IN-PLACE CONCRETE

ROOF DECK, FOR INSTALLATION OF NEW

ROOF ACCESS STAIR

TEMPORARILY FOLD, SEAL, AND SECURE

EXISTING ROOF MEMBRANE OVER

EDGE OF EXPOSED CBOC WALL.

SEE DETAIL 2/AD 301

REMOVE EXISTING ROOF

HATCH.

EXISTING ROOF BEAM TO REMAIN

EXISTING COLUMN (BELOW) TO REMAIN

LINE OF SEPARATION BETWEEN

ROOF TO REMAIN AND ROOF TO BE

REMOVED

SPECIAL NOTE:

DUE TO THE PROXIMITY OF THE EXISTING SILVER CROSS HOSPITAL (SCH) REMNANT TO THE EXISTING CBOC

STRUCTURE, THE CONTRACTOR SHALL TAKE PRECAUTIONS TO PREVENT DAMAGE, COLLAPSE, OR

WEAKENING OF THE EXISTING CBOC STRUCTURE:

1. DURING DEMOLITION WORK, THE CONTRACTOR SHALL CONDUCT DAILY ON-SITE SURVEYS OF THE

CONDITION OF THE CBOC STRUCTURE TO ASSESS ANY APPARENT DAMAGE TO CBOC STRUCTURE

INCLUDING BUT NOT LIMITED TO: FOUNDATIONS, STRUCTURAL FRAME, AND WALLS.

2. AT COMPLETION OF REMNANT STRUCTURE DEMOLITION WORK, THE CONTRACTOR SHALL, ON A WEEKLY BASIS, CONTINUE ON-SITE SURVEYS OF THE EXISTING WORK AT OR NEAR THE AREAS OF

DEMOLITION TO ASSESS ANY APPARENT DAMAGE TO THE EXISTING CBOC STRUCTURE.

3. PROVIDE TEMPORARY BRACING AND SHORING WITH CONNECTIONS OF SUFFICIENT STRENGTH TO BEAR IMPOSED LOADS, AND TO PROTECT ALL PERSONS AND PROPERTY, AND TO ENSURE PROPER ALIGNMENT. COMPLY WITH ALL STATE, O.S.H.A., VA REQUIREMENTS, AND LOCAL CODES. THE

CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR PROVIDING ADEQUATE BRACING OF

FOUNDATIONS, STRUCTURAL FRAME, AND WALLS DURING DEMOLITION. CONTRACTOR SHALL

ASSUME ALL RESPONSIBILITY FOR DAMAGE DUE TO HIS FAILURE TO TAKE SUCH PRECAUTIONS.

SYMBOLS LEGEND

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

0 EXISTING COLUMN

GRID LINE X

Room name

KEYNOTEX

ROOM NAME/NUMBER

0 NEW COLUMN

GRID LINE

PHOTOGRAPHY TAG (APPROXIMATE POSITION OF

CAMERA & ANGLE)1

EXISTING NORTHEAST VESTIBULE COMPOSITE ROOF

DECK TO BE REMOVED

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :2

P

M

AD 102

ROOF DEMOLITION PARTIAL

PLAN REMNANT STRUCTURE &

N.E. VESTIBULE

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/8" = 1'-0"

1 EXISTING ROOF PLAN LEVEL, NORTH PORTION OF ROOF

VIEW LOOKING NORTHEAST AT THE EXISTING CBOC NORTHEAST VESTIBULE ROOFVIEW LOOKING NORTH-NORTHEAST TOP OF THE SCH REMNANT STRUCTUREVIEW LOOKING NORTH-NORTHWEST TOP OF SCH REMNANT STRUCTURE

VIEW LOOKING EAST ALONG THE TEMPORARY PARAPET BETWEEN SCH REMNANT & CBOC

VIEW LOOKING WEST AT NORTHWEST CORNER OF CBOC AT SCH REMNANT

SOUTHERN EDGE OF

SCH REMNANT

WESTERN CBOC PARAPET

SOUTHERN EDGE OF

SCH REMNANT

CBOC ROOF

SCH REMNANT

SCH REMNANT

SCH REMNANT

CBOC ROOF

SCH PARAPET SUPPORTING CBOC

NORTHEAST VESTIBULE ROOF

CBOC ROOF

SCH REMNANT

CBOC PARAPET

SCH REMNANT

VIEW LOOKING NORTH AT NORTHWEST CORNER OF CBOC AT SCH REMNANT

ROOFING NOTE: PRESERVE AND PROTECT THE EXISTING

ROOFING MEMBRANE. MEMBRANE SHALL BE CAREFULLY

DRAPED OVER THE EDGE OF THE NORTH WALL OF THE CBOC

AND TEMPORARILY SECURED TO PROTECT THE CBOC ROOF

ONCE THE SCH REMNANT IS REMOVED.

SEE DETAIL 2/AD 301

4 5 6

0 4' 8' 16'

AREA OF

WORK

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

Gx

JxJx

KxKx

K'xK'x

LxLx

1x 4x 6x 9x 12x 13x3x 5x 5.8x 8x 10x6.1x 9.5x1.2x

15' - 0 1/8"

9'

/8

10' - 9 5/8" 10' - 9 5/8"

9'

/8

17' - 3 3/4"

9'

3/ 8"

/8

4' - 10"

5'

/4

7' - 7 7/8"

/4 "8'

X X X X X X

X X

X X

X

X

X

EXISTING CONSTRUCTION TO REMAIN

Room name

KEYNOTEX

ROOM NAME/NUMBER

0X

CENTERLINE

RCP SYMBOLS LEGEND

DEMOLITION

GYPSUM BOARD

2X4 LED TROFFER LIGHT TO BE

REMOVED

EXPOSED CONSTRUCTION

EXISTING LAY-IN ACOUSTICAL

CEILING TILE, GRID, & TRIM TO BE

REMOVED UNLESS NOTED OTHERWISE

CAN LIGHT TO BE REMOVED

EXISTING COLUMN

GRID LINE

CEILING MOUNTED EXIT SIGN TO BE

REMOVED

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

EXISTING CONSTRUCTION TO BE

DEMOLISHED

2X2 LED TROFFER LIGHT TO BE

REMOVED

EXISTING LAY-IN ACOUSTICAL

CEILING SYSTEM TO REMAIN

EXISTING 2X4 LED TROFFER LIGHT

TO REMAIN

EXISTING CAN LIGHT TO REMAIN

CEILING MOUNTED EXIT SIGN TO

TO REMAIN

EXISTING 2X2 LED TROFFER LIGHT

TO REMAIN

2X4 LED TROFFER LIGHT TO BE

REMOVED - PRESERVE & PROTECT

FOR REINSTALLATION IN SAME LOCATION

UNO

2X2 LED TROFFER LIGHT TO BE

REMOVED - PRESERVE & PROTECT

FOR REINSTALLATION IN SAME LOCATION

UNO

X

X

CAN LIGHT TO BE

REMOVED - PRESERVE & PROTECT

FOR REINSTALLATION IN SAME LOCATION

UNO

X

RCP DEMOLITION NOTES

A. LAY-IN CEILING TO BE REPLACED AS INDICATED.

B. ROOM LIGHTS ARE TO BE REINSTALLED. SEE ELECTRICAL

SHEETS FOR FIXTURE INFORMATION.

C. REMOVE (AND PRESERVE FOR REINSTALLATION) THE

FOLLOWING (BUT NOT LIMITED TO) CEILING MOUNTED

DEVICES, ITEMS, & FIXTURES:

a. SMOKE & HEAT DETECTORS

b. CAMERAS

c. WI-FI ANTENNAS

d. SPEAKERS

e. MIRRORS

f. EMERGENCY LIGHTS

g. NURSE CALL LIGHTS

h. SIGNS

i. DIFFUSERS AND GRILLES

j. VISUAL FIRE ALARMS

k. ARTWORK

l. SPRINKLER HEAD TRIM RINGS

m. CURTAIN TRACKS

n. MED GAS LINE ESCUTCHEONS

o. CEILING MOUNTED EXAM LIGHTS

D. PRESERVE EXISTING GYPSUM BOARD SOFFITS & CEILINGS.

REPAIR ANY DAMAGE AS A RESULT OF ADJACENT GENERAL

DEMOLITION WORK.

E. PRESERVE AND PROTECT EXISTING CEILING GRID AND TRIM

UNLESS NOTED OTHERWISE.

Elev. Equip.

B003

Badge B004

Phone B002C

Home Based Primary Care

B002

Stair #2 S-2

Comm.

B005

Reception B001

Women's Restroom

B006

Men's Restroom

B008

HAC

B007

Copy Room B009

Phone B002A

Phone B002B

Phone B017

Phone B016

A.O.

B015

Clinical Nurse Manager

B014

Chief Medical Director

B013

Corridor C0-2

Elevator

EL-1

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

N

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :3

P

M

AD 110

DEMOLITION REFLECTED

CEILING PLAN-BASEMENT

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/4" = 1'-0"

BASEMENT LEVEL REFLECTED CEILING PLAN

AREA OF

WORK

0 2' 4' 8'

Revisions Date

Jx

Kx

K'x

Lx

12x 13x 14x10x 15x

15y

9.5x

REMOVE EXISTING GWB SOFFIT

AT EXISTING ROOF LADDER

REMOVE PORTION OF EXISTING

CORRIDOR CEILING

2'

1/

4"

+/- 8' - 0 1/8"

REMOVE PORTION OF

EXISTING

DISPENSARY CEILING

+/- 5' - 7 3/8"

0'

/8

REMOVE PORTION OF

EXISTING

DIAGNOSTIC CEILING

REMOVE EXISTING

GYP. BOARD SOFFIT

REMOVE THESE LIGHT FIXTURES.

PRESERVE & PROTECT FOR

REINSTALLATION

REMOVE THESE LIGHT FIXTURES.

PRESERVE & PROTECT FOR

REINSTALLATION

REMOVE THIS LIGHT FIXTURE.

PRESERVE & PROTECT FOR

REINSTALLATION

X

X

X

X

X

X

EXISTING CONSTRUCTION TO REMAIN

Room name

KEYNOTEX

ROOM NAME/NUMBER

0X

CENTERLINE

RCP SYMBOLS LEGEND

DEMOLITION

GYPSUM BOARD

2X4 LED TROFFER LIGHT TO BE

REMOVED

EXPOSED CONSTRUCTION

EXISTING LAY-IN ACOUSTICAL

CEILING TILE, GRID, & TRIM TO BE

REMOVED UNLESS NOTED OTHERWISE

CAN LIGHT TO BE REMOVED

EXISTING COLUMN

GRID LINE

CEILING MOUNTED EXIT SIGN TO BE

REMOVED

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

EXISTING CONSTRUCTION TO BE

DEMOLISHED

2X2 LED TROFFER LIGHT TO BE

REMOVED

EXISTING LAY-IN ACOUSTICAL

CEILING SYSTEM TO REMAIN

EXISTING 2X4 LED TROFFER LIGHT

TO REMAIN

EXISTING CAN LIGHT TO REMAIN

CEILING MOUNTED EXIT SIGN TO

TO REMAIN

EXISTING 2X2 LED TROFFER LIGHT

TO REMAIN

2X4 LED TROFFER LIGHT TO BE

REMOVED - PRESERVE & PROTECT

FOR REINSTALLATION IN SAME LOCATION

UNO

2X2 LED TROFFER LIGHT TO BE

REMOVED - PRESERVE & PROTECT

FOR REINSTALLATION IN SAME LOCATION

UNO

X

X

CAN LIGHT TO BE

REMOVED - PRESERVE & PROTECT

FOR REINSTALLATION IN SAME LOCATION

UNO

X

RCP DEMOLITION NOTES

A. LAY-IN CEILING TO BE REPLACED AS INDICATED.

B. ROOM LIGHTS ARE TO BE REINSTALLED. SEE ELECTRICAL

SHEETS FOR FIXTURE INFORMATION.

C. REMOVE (AND PRESERVE FOR REINSTALLATION) THE

FOLLOWING (BUT NOT LIMITED TO) CEILING MOUNTED

DEVICES, ITEMS, & FIXTURES:

a. SMOKE & HEAT DETECTORS

b. CAMERAS

c. WI-FI ANTENNAS

d. SPEAKERS

e. MIRRORS

f. EMERGENCY LIGHTS

g. NURSE CALL LIGHTS

h. SIGNS

i. DIFFUSERS AND GRILLES

j. VISUAL FIRE ALARMS

k. ARTWORK

l. SPRINKLER HEAD TRIM RINGS

m. CURTAIN TRACKS

n. MED GAS LINE ESCUTCHEONS

o. CEILING MOUNTED EXAM LIGHTS

D. PRESERVE EXISTING GYPSUM BOARD SOFFITS & CEILINGS.

REPAIR ANY DAMAGE AS A RESULT OF ADJACENT GENERAL

DEMOLITION WORK.

E. PRESERVE AND PROTECT EXISTING CEILING GRID AND TRIM

UNLESS NOTED OTHERWISE.

Elevator

EL-1

Stair #2 S-2

Corridor C1-15

Dispensary

Diagnostic

Corridor C1-14

Elec.

Storage 1116A

Corridor C1-15

Egress

Corridor

Exit

Vestibule

Storage

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

N

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :3

P

M

AD 111

DEMOLITION REFLECTED

CEILING PLAN-1ST FLOOR

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/4" = 1'-0"

1 FIRST FLOOR LEVEL DEMO RCP - PARTIAL

AREA OF

WORK

0 2' 4' 8'

Revisions Date

BASEMENT LEVEL

601' - 8 1/2"

ROOF NORTH

628' - 10 1/2"

FIRST FLOOR

LEVEL

616' - 2 1/2"

Hx

EXISTING

T/FOOTING

600' - 8 1/2"

EXISTING VA JOLIET CBOC EXISTING SCH REMNANT

+/- 2' - 10"

EXISTING EPDM ROOF MEMBRANE

DRAPED OVER EXISTING SCH

WALL REMNANT, SEE ROOFING NOTE.

EXISTING ROOF INSULATION

EXISTING CAST-IN-PLACE

CONCRETE FRAME

STRUCTURE

EXISTING CAST-IN-PLACE

CONCRETE ROOF

DECK

EXISTING STEEL DECK SPANNING

THE INTERSTITIAL SPACE

STEEL SUPPORT ANGLES

CONTINUOUS EACH SIDE OF

INTERSTITIAL SPACE

EXISTING 8" CMU INFILL

EXISTING BRICK MASONRY WITH

STONE VENEER - SCH: TO BE

DEMOLISHED

EXISTING CAST-IN-PLACE CONCRETE

FLOOR - SCH

EXISTING CAST-IN-PLACE CONCRETE

FLOOR - SCH: TO BE DEMOLISHED

EXISTING SCH FOOTING

TO BE DEMOLISHED

EXISTING CAST-IN-PLACE CONCRETE

FOUNDATION WALL - CBOC

EXISTING CAST-IN-PLACE CONCRETE

FLOOR SLAB - CBOC

EXISTING CAST-IN-PLACE

CONCRETE FOOTING

EXISTING FILL, COMPOSITION UNKNOWN,

SUSPECT CRUSHED STONE

EXISTING SCH REMNANT TO BE DEMOLISHED

ROOFING NOTE: PRESERVE AND PROTECT THE EXISTING

ROOFING MEMBRANE. MEMBRANE SHALL BE CAREFULLY

DRAPED OVER THE EDGE OF THE NORTH WALL OF THE CBOC

AND TEMPORARILY SECURED TO PROTECT THE CBOC ROOF

ONCE THE SCH REMNANT IS REMOVED.

SPECIAL NOTE:

DUE TO THE PROXIMITY OF THE EXISTING SILVER CROSS HOSPITAL (SCH) REMNANT TO THE EXISTING CBOC

STRUCTURE, THE CONTRACTOR SHALL TAKE PRECAUTIONS TO PREVENT DAMAGE, COLLAPSE, OR

WEAKENING OF THE EXISTING CBOC STRUCTURE:

1. DURING DEMOLITION WORK, THE CONTRACTOR SHALL CONDUCT DAILY ON-SITE SURVEYS OF THE

CONDITION OF THE CBOC STRUCTURE TO ASSESS ANY APPARENT DAMAGE TO CBOC STRUCTURE

INCLUDING BUT NOT LIMITED TO: FOUNDATIONS, STRUCTURAL FRAME, AND WALLS.

2. AT COMPLETION OF REMNANT STRUCTURE DEMOLITION WORK, THE CONTRACTOR SHALL, ON A WEEKLY BASIS, CONTINUE ON-SITE SURVEYS OF THE EXISTING WORK AT OR NEAR THE AREAS OF

DEMOLITION TO ASSESS ANY APPARENT DAMAGE TO THE EXISTING CBOC STRUCTURE.

3. PROVIDE TEMPORARY BRACING AND SHORING WITH CONNECTIONS OF SUFFICIENT STRENGTH TO BEAR IMPOSED LOADS, AND TO PROTECT ALL PERSONS AND PROPERTY, AND TO ENSURE PROPER ALIGNMENT. COMPLY WITH ALL STATE, O.S.H.A., VA REQUIREMENTS, AND LOCAL CODES. THE

CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR PROVIDING ADEQUATE BRACING OF

FOUNDATIONS, STRUCTURAL FRAME, AND WALLS DURING DEMOLITION. CONTRACTOR SHALL

ASSUME ALL RESPONSIBILITY FOR DAMAGE DUE TO HIS FAILURE TO TAKE SUCH PRECAUTIONS.

ROOF NORTH

628' - 10 1/2"

EXISTING VA JOLIET CBOC

EXISTING ROOF INSULATION

EXISTING CAST-IN-PLACE

CONCRETE FRAME

STRUCTURE

EXISTING CAST-IN-PLACE

CONCRETE ROOF

DECK

EXISTING 8" CMU INFILL

ROOFING NOTE: PRESERVE AND PROTECT THE EXISTING

ROOFING MEMBRANE. MEMBRANE SHALL BE CAREFULLY

DRAPED OVER THE EDGE OF THE NORTH WALL OF THE CBOC

AND TEMPORARILY SECURED TO PROTECT THE CBOC ROOF

ONCE THE SCH REMNANT IS REMOVED.

DEMOLISHED SCH REMNANT

CONTINUOUS 2x PRESSURE TREATED WOOD

BLOCKING TO SUPPORT EXISTING MEMBRANE

CONTINUOUS TEMPORARY PRESSURE BAR,

ANCHOR TO EXISTING CBOC STRUCTURE

TEMPORARILY PROTECT EXPOSED EXTERIOR WALLS

OF CBOC USING SUITABLE WEATHER RESISTANT

MEMBRANE BARRIER

SYMBOLS LEGEND

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

0 EXISTING COLUMN

GRID LINE X

Room name

KEYNOTEX

ROOM NAME/NUMBER

0 NEW COLUMN

GRID LINE

PHOTOGRAPHY TAG (APPROXIMATE POSITION OF

CAMERA & ANGLE)1

NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS

Name Elevation

FLOOR/LEVEL ELEVATION

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :3

P

M

AD 301

DEMOLITION WALL SECTION &

DETAILS AT REMNANT

STRUCTURE

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/2" = 1'-0"

EXISTING WALL SECTION - INTERSTITIAL SPACE

EXISTING SCH

REMNANT

EXISTING CBOC

TYPICAL VIEW LOOKING TOWARDS EXISTING ROOF DECK WITHIN EXISTING INTERSTITIAL SPACE

EXISTING SCH

REMNANT

EXISTING CBOC

TYPICAL VIEW LOOKING AT FOUNDATION WALLS WITHIN EXISTING INTERSTITIAL SPACE

1/2" = 1'-0"

EXISTING ROOF AT REMNANT STRUCTURE - DETAIL OF TEMPORARY ROOFING

4'0 1' 2'

0 1' 2' 4'

AREA OF

WORK

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

Hx

Jx

Kx

K'x

Lx

1x

4x

6x

9x 12x 13x 14x

3x 5x

5.8x

8x

10x6.1x 15x9.5x

1'

1'

AD 301

1.2x

SCH REMNANT

JOLIET CBOC

SCH REMNANT

JOLIET CBOC

EXISTING INTERSTITIAL SPACE

EXISTING INTERSTITIAL SPACE

EXISTING FOOTINGS

EXISTING NORTHEAST

VESTIBULE, CBOC

EXISTING BASEMENT LEVEL

JOLIET CBOC

EXISTING SILVER CROSS HOSPITAL (SCH)

EXISTING SILVER CROSS HOSPITAL (SCH)

CAST-IN-PLACE CONCRETE

FOUNDATION WALLS, CBOC - TYPICAL

EXISTING MASONRY FOUNDATION WALLS,

SCH - TYPICAL

8'

0"

4'

+/- 132' - 3 3/4"

600' - 8 1/2"

600' - 8 1/2"

1' - 8" 26' - 0" 23' - 0" 24' - 0" 24' - 0"

5' - 11 1/2"

/2

/4

/2

/2

42' - 6 1/2" 58' - 1"

/4

4'

5' - 10"

1'

1' - 4"

+/- 79' - 6 1/4"

+/- 41' - 6"

3'

8' - 0" 8'

2'

1/

2"

2'

1/ 2"

2' - 3 1/2"

EXISTING

CAST-IN-PLACE

CONCRETE COLUMNS,

TYPICAL

600' - 8 1/2"

600' - 8 1/2"

AD 301

AD 301

SYMBOLS LEGEND

EXISTING SCH MASONRY FOUNDATION WALLS

0X

EXISTING SCH FOOTINGS

EXISTING CBOC FOOTINGS

EXISTING CBOC FOUNDATIONS

EXISTING COLUMN

GRID LINE

444 W. Lake St. Suite 1700 Chicago, IL 60606

312.583.7023 www.virtualenergysolutions.com

Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432

Drawing No.

Scale:

Date:

Checked By:Drawn By:Designed By:

Drawing Title:

Contract No.

File No.Building No.

Client Project No.

Project Title:Approved: Chief, failites Management Services

Approved: Medical Center Director

Approved:

Approved: Location:

VES Project Number: 191006

AS NOTED

VA JOLIET CBOC

JOLIET, ILLINOIS

578-371 36C25219D0020

© 2020 Virtual Energy Solutions, INC.

10/11/2023

B

IM

/2

-M

A T

O C

-P a rk in g E x p a n s io n a t J o lie t C

B O

C

-3

/2

J o lie t

C B

O C

P a rk in g E x p a n s io n V

E S

A rc h

.r v t

-1

-0

:1 :4

P

M

AE 100F

EXISTING FOUNDATIONS,

PARTIAL PLAN

PARKING EXPANSION AT

JOLIET CBOC

GCGIDGID

1/8" = 1'-0"

EXISTING FOOTINGS/FOUNDATIONS (FOR REFERENCE)

NOTE: PLAN PROVIDED FOR REFERENCE ONLY. EXACT EXISTING FOUNDATION CONDITIONS REQUIRE FIELD INVESTIGATION. ALL DIMENSIONS

AND ELEVATIONS SHOWN ARE CONSIDERED APPROXIMATE.

0 4' 8' 16'

Revisions Date

ISSUED FOR 30% SD 10/07/2022

ISSUED FOR 60% DD 12/30/2022

ISSUED FOR 90% PRICING 02/02/2023

ISSUED FOR 90% CD 02/10/2023

ISSUED FOR 100% CD 03/07/2023

ISSUED FOR BID 03/24/2023

AD 100 - BASEMENT DEMOLITION PLAN REMNANT STRUCTURE & N-E- VESTIBULE
AD 101 - FIRST FLOOR DEMOLITION PLAN REMNANT STRUCTURE & N-E- VESTIBULE
AD 102 - ROOF DEMOLITION PARTIAL PLAN REMNANT STRUCTURE & N-E- VESTIBULE
AD 110 - DEMOLITION REFLECTED CEILING PLAN-BASEMENT
AD 111 - DEMOLITION REFLECTED CEILING PLAN-1ST FLOOR
AD 301 - DEMOLITION WALL SECTION & DETAILS AT REMNANT STRUCTURE
AE 100F - EXISTING FOUNDATIONS, PARTIAL PLAN
GC 009 - ROOF LEVEL PLAN-NEW CONSTRUCTION PHASING
GC 010 - SITE WORK PLAN - NEW CONSTRUCTION PHASING
GC 007 - BASEMENT LEVEL PLAN-NEW CONSTRUCTION PHASING
GC 008 - FIRST FLOOR LEVEL PLAN-NEW CONSTRUCTION PHASING

File details come from the government source that posted it. Updated .