ATT - 22 578-23-013 Asbestos Quantity Estimates.pdf

PDF 110 KB Posted

Attached to
Z1DA--578-23-013 Abatement Task Order D
Solicitation number
36C25225B0026
Issued by

About this file

This document is an asbestos survey and material assessment report covering multiple rooms (C130, C307, F350, B209, B313, D239, and A306) within a facility. The survey details the locations, quantities, and characteristics of various building materials, including vinyl floor tiles (VFT), mastic, plaster walls, acoustical ceiling tiles (ACT), baseboard, and pipe systems. Each room's materials are evaluated for asbestos content, with most materials categorized as having low potential for distribution and in good condition. Consistent notation throughout the document includes presumptions about asbestos potentially being present behind walls and above ceilings, with most areas marked as "NO CHANGE" in the 2010 reevaluation. The assessment uses specific sample codes (e.g., 98032-X, 98051-X) to identify and track different material types, with detailed descriptions of material color, size, and condition.

View the file

Other files

File Type Posted
S05 Pre-Bid RFIs 12.18.25.xlsx XLSX spreadsheet
S05 Pre-Bid RFIs 11.25.25.xlsx XLSX spreadsheet
ATT - Contractor Village.png PNG image
S05 Pre-Bid RFIs 10.30.25.xlsx XLSX spreadsheet
ATT - 15th Floor Legend.png PNG image
ATT - Loading Dock Area.png PNG image
ATT - Service Elevators.png PNG image
ATT - 238200.pdf PDF
36C25225B0026 0003.docx DOCX document
36C25225B0026 0002.docx DOCX document
079200 JOINT SEALANTS.pdf PDF
S05 Pre-Bid RFIs 10.2.25.xlsx XLSX spreadsheet
36C25225B0026 0001.docx DOCX document
078400 FIRESTOPPING.pdf PDF
ATT - 21 Specifications 578-23-013.pdf PDF
ATT - 20g VHA ICRA-1.3 Task 7.pdf PDF
ATT - 20b VHA ICRA-1.3 Task 2.pdf PDF
ATT - 1 Hines Underground Utility Plan.pdf PDF
36C25225B0026_1.docx DOCX document
ATT - 23 578-23-013 Task Locations.pdf PDF
ATT - 20c VHA ICRA-1.3 Task 3.pdf PDF
ATT - 20a VHA ICRA-1.3 Task 1.pdf PDF
ATT - 19 Interim Life Safety Measures.pdf PDF
ATT - 18g VHA PCRA 2024_1.1_Task 7.pdf PDF
ATT - 18f VHA PCRA 2024_1.1_Task 6.pdf PDF
ATT - 10 Fire Protection Code Reviews.pdf PDF
ATT - 7 Infection Control Barrier Sample.pdf PDF
ATT - 3 Parking Designations 08042025.pdf PDF
ATT - 2 HINES VA SITE PLAN 5-1-2025.pdf PDF
ATT - 20e VHA ICRA-1.3 Task 5.pdf PDF
ATT - 20d VHA ICRA-1.3 Task 4.pdf PDF
ATT - 18d VHA PCRA 2024_1.1_Task 4.pdf PDF
ATT - 18c VHA PCRA 2024_1.1_Task 3.pdf PDF
ATT - 18a VHA PCRA 2024_1.1_Task 1.pdf PDF
ATT - 15 Hines COVID-19 Guidelines.pdf PDF
ATT - 12 Cutting Welding and Other Hot Work.pdf PDF
ATT - 11 No Smoking Policy 10-1-19.pdf PDF
ATT - 8 Dig Permit SOP Form.pdf PDF
ATT - 4 Contractor Badging - Fingerprint Request Form.pdf PDF
P07 Wage Determination.pdf PDF
ATT - 20f VHA ICRA-1.3 Task 6.pdf PDF
ATT - 18e VHA PCRA 2024_1.1_Task 5.pdf PDF
ATT - 18b VHA PCRA 2024_1.1_Task 2.pdf PDF
ATT - 17 Emergency Contact List - Template.pdf PDF
ATT - 16 VHA Supplemental Contract Requirements for Ensuring Adequate COVID-19 Safety Protocols for Federal Contractors rev2.pdf PDF
ATT - 14 OIT Horizontal Cable Requirements.pdf PDF
ATT - 13 Asbestos Survey Glossary.pdf PDF
ATT - 9 Above Ceiling Permits.pdf PDF
ATT - 6 Pre-Construction Checklist Rev 07.27.2021.pdf PDF
ATT - 5 Safety and Health During Construction Activities.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THIS DOCUMENT IS FOR REFERENCE ONLY. CONTRACTOR MUST VERIFY ALL QUANTITIES.

LOCATION ACM % TYPE QTY SAMPLE

MATERIAL

DESCRIPT

ION REEVALUATION 2010 COMMENTS

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

ROOM C130

7 VFT 12 CHR 225 SF 98032-X 1'X1' BRN W N GOOD LOW NO CHANGE

MSTC <1 CHR 225 SF 98032-X MSTC FOR N GOOD LOW NO CHANGE

PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 225 SF 98102-X 2'X4' WHT W Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASS Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASS Y N/A LOW Presume behind walls & above ceilings

MSTC 0 N/A 30 SF 98328-X MSTC FOR N GOOD LOW NO CHANGE

BSBRD 0 N/A 30 SF 98329-X 6" TAN BSB N GOOD LOW NO CHANGE

ROOM C307

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER FLOORTILE AND MASTIC

PLAS-W 0 432 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A 18 SF 98058-X 4" BLK BSB N GOOD LOW NO CHANGE

MSTC 0 N/A 18 SF 98059-X MSTC FOR N GOOD LOW NO CHANGE

ACT 0 N/A 182 SF 98102-X 2'X4' WHT W Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASS Y GOOD LOW NO CHANGE

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASS Y N/A LOW Presume behind walls & above ceilings

ROOM F350

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER LEVELER OVER TILE

NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE

ACT 0 N/A 112 SF 97271-X 2'X4' WHT W Y GOOD LOW NO CHANGE

PLAS-W 0 N/A 350 SF 97272-X PLAS N GOOD MOD NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASS Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASS Y N/A LOW Presume behind walls & above ceilings

MSTC 0 N/A 22 SF 98328-X MSTC FOR N GOOD LOW NO CHANGE

BSBRD 0 N/A 22 SF 98329-X 6" TAN BSB N GOOD LOW NO CHANGE

ROOM B209

VFT 0 N/A 112 SF 98033-X

1'X1' CRM

W/LT

FLKS BRN N GOOD LOW NO CHANGE

MSTC 0 N/A 112 SF 98033-X

MSTC

FOR 98033

LAB

RESULT N GOOD LOW NO CHANGE

PLAS-W 0 N/A 350 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A 15 SF 98058-X

4" BLK

BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 15 SF 98059-X

MSTC

FOR 98058 N GOOD LOW NO CHANGE

ACT 0 N/A 112 SF 98102-X

2'X4' WHT

WRM

W/PNHL Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X

N-ACC

ASSUMED

POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X

N-ACC

ASSUMED

POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM B313

7 VFT 2 CHR 230 SF 98037-X

1'X1' BRN

W/WHT

MOT N GOOD LOW NO CHANGE

7 MSTC 15 CHR 230 SF 98037-X

MSTC

FOR 98037

LAB

RESULT N GOOD LOW NO CHANGE

PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD N/A N/A 20 SF 98056-X

4" BRN

BSBRD N GOOD LOW NO CHANGE

MSTC N/A N/A 20 SF 98057-X

MSTC

FOR 98056 N GOOD LOW NO CHANGE

ACT N/A N/A 224 SF 98102-X

2'X4' WHT

WRM

W/PNHL Y GOOD LOW NO CHANGE

7 PIPE-STM 7 CHR N/A 98137-X

N-ACC

ASSUMED

POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 7 CHR N/A 98212-X

N-ACC

ASSUMED

POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM D239

NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE

PLAS-A 0 N/A 112 SF 98101-X PLAS N GOOD MOD NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASS Y GOOD LOW Presume behind walls & above ceilings

PIPE F-

STM 0 N/A 20 LF 98143-X STM FITG Y GOOD LOW NO CHANGE

PIPE-

COND 70 CHR 98212-X N-ACC ASS Y GOOD LOW Presume behind walls & above ceilings

PLAS-W 0 N/A 350 SF 98350-X PLAS N GOOD MOD NO CHANGE

7 VFT 25 CHR 112 SF 97263- 9"X9" CONF N GOOD LOW NO CHANGE

7 MSTC 25 CHR 112 SF 97264- MSTC FOR N GOOD LOW NO CHANGE

ROOM A306

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

DUCT N/A N/A 100 SF N/A

DUCT INS

NS N/A N/A N/A NO CHANGE

NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE

VFT <1 CHR 280 SF 98024-X

1'X1' GRN

W/SM

GRN STRK N GOOD LOW NO CHANGE

7 MSTC 5 CHR 280 SF 98025-X

MSTC

FOR 98024 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 970 SF 98051-X PLAS N GOOD MOD NO CHANGE

PLAS-A 0 N/A 448 SF 98101-X PLAS N GOOD MOD NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X

N-ACC

ASSUMED

POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE F-

STM 0 N/A 13 LF 98142-X

ELBOW

STEAM

(FG PIPE) Y GOOD LOW NO CHANGE

PIPE F-

STM 0 N/A 10 LF 98143-X

ELBOW

STEAM

(FG PIPE) Y GOOD LOW NO CHANGE

PIPE-

COND 70 CHR N/A 98212-X

N-ACC

ASSUMED

POSITIVE Y N/A LOW Presume behind walls & above ceilings