This document is an asbestos survey and material assessment report covering multiple rooms (C130, C307, F350, B209, B313, D239, and A306) within a facility. The survey details the locations, quantities, and characteristics of various building materials, including vinyl floor tiles (VFT), mastic, plaster walls, acoustical ceiling tiles (ACT), baseboard, and pipe systems. Each room's materials are evaluated for asbestos content, with most materials categorized as having low potential for distribution and in good condition. Consistent notation throughout the document includes presumptions about asbestos potentially being present behind walls and above ceilings, with most areas marked as "NO CHANGE" in the 2010 reevaluation. The assessment uses specific sample codes (e.g., 98032-X, 98051-X) to identify and track different material types, with detailed descriptions of material color, size, and condition.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THIS DOCUMENT IS FOR REFERENCE ONLY. CONTRACTOR MUST VERIFY ALL QUANTITIES.
LOCATION ACM % TYPE QTY SAMPLE
MATERIAL
DESCRIPT
ION REEVALUATION 2010 COMMENTS
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
ROOM C130
7 VFT 12 CHR 225 SF 98032-X 1'X1' BRN W N GOOD LOW NO CHANGE
MSTC <1 CHR 225 SF 98032-X MSTC FOR N GOOD LOW NO CHANGE
PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 225 SF 98102-X 2'X4' WHT W Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASS Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASS Y N/A LOW Presume behind walls & above ceilings
MSTC 0 N/A 30 SF 98328-X MSTC FOR N GOOD LOW NO CHANGE
BSBRD 0 N/A 30 SF 98329-X 6" TAN BSB N GOOD LOW NO CHANGE
ROOM C307
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER FLOORTILE AND MASTIC
PLAS-W 0 432 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A 18 SF 98058-X 4" BLK BSB N GOOD LOW NO CHANGE
MSTC 0 N/A 18 SF 98059-X MSTC FOR N GOOD LOW NO CHANGE
ACT 0 N/A 182 SF 98102-X 2'X4' WHT W Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASS Y GOOD LOW NO CHANGE
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASS Y N/A LOW Presume behind walls & above ceilings
ROOM F350
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER LEVELER OVER TILE
NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE
ACT 0 N/A 112 SF 97271-X 2'X4' WHT W Y GOOD LOW NO CHANGE
PLAS-W 0 N/A 350 SF 97272-X PLAS N GOOD MOD NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASS Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASS Y N/A LOW Presume behind walls & above ceilings
MSTC 0 N/A 22 SF 98328-X MSTC FOR N GOOD LOW NO CHANGE
BSBRD 0 N/A 22 SF 98329-X 6" TAN BSB N GOOD LOW NO CHANGE
ROOM B209
VFT 0 N/A 112 SF 98033-X
1'X1' CRM
W/LT
FLKS BRN N GOOD LOW NO CHANGE
MSTC 0 N/A 112 SF 98033-X
MSTC
FOR 98033
LAB
RESULT N GOOD LOW NO CHANGE
PLAS-W 0 N/A 350 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A 15 SF 98058-X
4" BLK
BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 15 SF 98059-X
MSTC
FOR 98058 N GOOD LOW NO CHANGE
ACT 0 N/A 112 SF 98102-X
2'X4' WHT
WRM
W/PNHL Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X
N-ACC
ASSUMED
POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X
N-ACC
ASSUMED
POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM B313
7 VFT 2 CHR 230 SF 98037-X
1'X1' BRN
W/WHT
MOT N GOOD LOW NO CHANGE
7 MSTC 15 CHR 230 SF 98037-X
MSTC
FOR 98037
LAB
RESULT N GOOD LOW NO CHANGE
PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD N/A N/A 20 SF 98056-X
4" BRN
BSBRD N GOOD LOW NO CHANGE
MSTC N/A N/A 20 SF 98057-X
MSTC
FOR 98056 N GOOD LOW NO CHANGE
ACT N/A N/A 224 SF 98102-X
2'X4' WHT
WRM
W/PNHL Y GOOD LOW NO CHANGE
7 PIPE-STM 7 CHR N/A 98137-X
N-ACC
ASSUMED
POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 7 CHR N/A 98212-X
N-ACC
ASSUMED
POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM D239
NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE
PLAS-A 0 N/A 112 SF 98101-X PLAS N GOOD MOD NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASS Y GOOD LOW Presume behind walls & above ceilings
PIPE F-
STM 0 N/A 20 LF 98143-X STM FITG Y GOOD LOW NO CHANGE
PIPE-
COND 70 CHR 98212-X N-ACC ASS Y GOOD LOW Presume behind walls & above ceilings
PLAS-W 0 N/A 350 SF 98350-X PLAS N GOOD MOD NO CHANGE
7 VFT 25 CHR 112 SF 97263- 9"X9" CONF N GOOD LOW NO CHANGE
7 MSTC 25 CHR 112 SF 97264- MSTC FOR N GOOD LOW NO CHANGE
ROOM A306
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
DUCT N/A N/A 100 SF N/A
DUCT INS
NS N/A N/A N/A NO CHANGE
NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE
VFT <1 CHR 280 SF 98024-X
1'X1' GRN
W/SM
GRN STRK N GOOD LOW NO CHANGE
7 MSTC 5 CHR 280 SF 98025-X
MSTC
FOR 98024 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 970 SF 98051-X PLAS N GOOD MOD NO CHANGE
PLAS-A 0 N/A 448 SF 98101-X PLAS N GOOD MOD NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X
N-ACC
ASSUMED
POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE F-
STM 0 N/A 13 LF 98142-X
ELBOW
STEAM
(FG PIPE) Y GOOD LOW NO CHANGE
PIPE F-
STM 0 N/A 10 LF 98143-X
ELBOW
STEAM
(FG PIPE) Y GOOD LOW NO CHANGE
PIPE-
COND 70 CHR N/A 98212-X
N-ACC
ASSUMED
POSITIVE Y N/A LOW Presume behind walls & above ceilings