Atch 11_USDA Ames IFC Volume 2 Dwgs 2 of 3.pdf
PDF 13 MB Posted
- Solicitation number
- 12639525R0012
About this file
These are electrical, communications, security, and lightning protection design drawings for Building 21 at the USDA National Centers for Animal Health in Ames, Iowa. The comprehensive set of drawings includes detailed plans for:
Electrical systems covering lighting plans for ground and penthouse levels, with specifications for fixture types, control schematics, and dimming configurations. Communications and security drawings outline cable tray installations, camera placement, access control systems, and riser diagrams. The lightning protection details specify grounding methods, air terminal placements, and bonding requirements for structural elements. Drawings are dated May 31, 2019, and were prepared by Stanley Consultants for the Mycobacteriology Laboratory Relocation project, with a focus on precise technical specifications for electrical infrastructure, communications networks, security systems, and protective electrical installations.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
A
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
MYCOBACTERIOLOGY LABORATORY RELOCATION
AMES, IOWA
27100.10
Ka
Ka2 Ka2
Ka
LI-2
Ka
Ka
Kb4 Kb4 Kb4 Kb4
Ka
MECHANICAL
Ka
LI-2
KEYPLAN
1 2
3 4
BUILDING 21
PENTHOUSE LEVEL LIGHTING PLAN
AREA 1
EL121 0
1/4" = 1'-0"
JM DANIELSON
DL GEORGE
PENTHOUSE LEVEL LIGHTING PLAN - AREA 1
MATCH LINE - FOR CONT SEE DWG EL123
M A
T C
H L
IN
E F
O R C
O N
T S
E E D
W G E
L
A.5
12.51211.5 13 14
A.4
A.3
A.2
NORTH
(TYPICAL FOR PENTHOUSE).
MYERS RLY-SW-2, OR EQUAL. SEE DETAIL ON DRAWING EL501
PENTHOUSE LEVEL PLANS POWERED BY INVERTER CIRCUIT LI-2 VIA
EMERGENCY LIGHT FIXTURES, INCLUDING TYPE L, SHOWN ON 3.
CONTROL PANELS OR SERVICE AREAS (TYPICAL FOR PENTHOUSE).
EQUIPMENT IS LOCATED. EXTRA LIGHTING MAY BE REQUIRED AT
FIXTURE PLACEMENT MAY CHANGE WHEN LAYOUT OF MECHANICAL 2.
FOR LIGHTING PLAN GENERAL NOTES SEE DRAWING EL111.1.
NOTES:
MAY 31, 2019
NC VEEN
NC VEEN
RJ LUKKARINEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
G
K
L
S
3a
X2 3b c
Ka Ka2 Ka2 Ka2
KaKa2Ka2Ka
Kb Kb4 Kb4 Kb4 Kb4
Kb
Kc
Kc
Kc
LI-2
P4-P1B-2
Kb
Ka
LI-2
STAIR
STORAGE
MECHANICAL
DWG EL112.
CONTINUATION SEE
CIRCUIT. FOR CIRCUIT
PART OF LI-2
Ka
LI-2
LI-2
LI-2 LI-2
LI-2
KEYPLAN
AREA 2
EL122 0
1/4"=1'-0"
ML MARTZ
PENTHOUSE LEVEL LIGHTING PLAN - AREA 2
MATCH LINE - FOR CONT SEE DWG EL124
M A
T C
H L
IN
E F
O R C
O N
T S
E E D
W G E
L
A.5
18 18.5 17.11716
A.4
A.3
A.2
19 17.720
DD
EE
FF
NORTH
FOR LIGHTING PLAN GENERAL NOTES SEE DRAWING EL111.1.
NOTES:
FOR ROOM TYPE.
CONTROL SCHEMATIC AND LIGHTING SEQUENCE OF OPERATION
SEE EL500 SERIES DRAWINGS FOR CORRESPONDING LIGHTING A.-J.
KEYNOTES:
H
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
VA-8 3
c
VA-8 25
d
VA-8 3
c
VA-8 3
c
VA-8 25
d
VA-8 25
d d c
L
3b3a
Kb
LI-2
KbKb4 Kb4
LI-2
X2
MECHANICAL
L LI-2
LI-2
KEYPLAN
AREA 3
EL123 0
PENTHOUSE LEVEL LIGHTING PLAN - AREA 3
M A
T C
H L
IN
E F
O R C
O N
T S
E E D
W G E
L
1512.51211.5 13 14
A.1
A.2
MATCH LINE - FOR CONT SEE DWG EL121
B
C
NORTH
FOR LIGHTING PLAN GENERAL NOTES SEE DRAWING EL111.1.
NOTES:
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
VC-4-E
VA-8 25
d
VA-8 3
c
VA-8 25
d c
VA-8 3
c
FROM LEVEL
BELOW
Kb
Kb KbKb4 Kb4
P4-P1B-4
Kb
ELECTRICAL
MECHANICAL
LI-2
LI-2
LI-2
P -1
.1
P -1
.2
E F -1
.2 HRU-14.1 HRC-14.2 HRC-14.3
EF-11.2EF-11.1 EF-11.3
E F -1
.1
E F -1
.2
EF-13.1 EF-13.2
P-10.2
P-10.1
CH-10.1
A C -1
.1CND-A
ROOM
CND-B
ROOM
VAV-202
KEYPLAN
AREA 4
EL124 0
PENTHOUSE LEVEL LIGHTING PLAN - AREA 4
MATCH LINE - FOR CONT SEE DWG EL122
M A
T C
H L
IN
E F
O R C
O N
T S
E E D
W G E
L
15 18 18.5 17.11716
A.2
19 17.720
FF
GG
HH
D
A.1
B
C
JJ
BLDG 21
WALKWAY
NORTH
LI
FOR LIGHTING PLAN GENERAL NOTES SEE DRAWING EL111.1.
NOTES:
P4-P1B
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
LIGHTING DETAILS
SHEET 1
EL500 0
NONE
KS HENNEMAN
BB
C C
A
WILL TURN ON
AND EMERGENCY RELAY PACK
EMERGENCY LIGHTING CIRCUIT
-LIGHTS CONNECTED TO THE
EMERGENCY POWER OUTAGE
- ON/OFF CONTROL OF LIGHTS
MANUAL CONTROL
-LIGHTS AUTOMATICALLY TURN OFF
INACTIVITY)
VACANCY (20 MINUTES OF
ENTERS
TO 100% OUTPUT WHEN OCCUPANT
-LIGHTS AUTOMATICALLY TURN ON
OCCUPANCY
TOGETHER
- ALL FIXTURES ARE CONTROLLED
0-10V WIRING
- ALL LIGHTS ARE DIMMABLE VIA
LIGHTS
SEQUENCE OF OPERATION:
SEE GENERAL NOTE 9.
CONTROL NETWORK.
TO BUILDING LIGHTING
A
DD
DEVICE LEGEND
DESIGNATION
A
DESCRIPTION
INITIAL LIGHT OUTPUT. SEE GENERAL NOTE 10.
RELAY POWER MODULE WITH 0-10V DIMMING OUTPUT, PRE-PROGRAMMED TO ENERGIZE AT 50%
INTEGRATED PASSIVE INFRARED OCCUPANCY SENSOR. CAT5E CONNECTIVITY
ON/OFF & RAISE/LOWER SMART WALL SWITCH,
AUTOMATIC RECEPTACLE CONTROL (ARC) RELAY PACK
LIGHTS
- ON/OFF & RAISE/LOWER CONTROL OF
MANUAL CONTROL
-ARC-ENABLED RECEPTACLES TURN OFF
HVAC/BMS SYSTEM
-ROOM CHANGES TO VACANT STATE FOR
-LIGHTS AUTOMATICALLY TURN OFF
VACANCY (20 MINUTES OF INACTIVITY)
HVAC/BMS SYSTEM
-ROOM CHANGES TO OCCUPIED STATE FOR
-ARC ENABLED RECEPTACLES TURN ON
FOR 100%
-LIGHTS MUST BE MANUALLY TURNED ON
-LIGHTS COME ON AUTOMATICALLY TO 50%
OCCUPANCY
TOGETHER
- ALL FIXTURES ARE CONTROLLED
WIRING
- ALL LIGHTS ARE DIMMABLE VIA 0-10V
LIGHTS
SEQUENCE OF OPERATION:
B C A
LIGHTING CONTROL SCHEMATIC PLAN -
SMALL OFFICE
THIS SCHEMATIC APPLIES TO THE ROOMS MARKED WITH ON LIGHTING PLANS.1.
NOTES:
B
C
ARC
DEVICE LEGEND
DESIGNATION
A
DESCRIPTION
GENERAL NOTE 10.
RELAY MODULE WITH 0-10V DIMMING OUTPUT. SEE
B ON/OFF SMART WALL SWITCH
C DUAL TECHNOLOGY OCCUPANCY SENSOR
D
EMERGENCY RELAY PACK WILL TURN ON
EMERGENCY LIGHTING CIRCUIT AND
-LIGHTS CONNECTED TO THE
EMERGENCY POWER OUTAGE
- ON/OFF CONTROL OF ENTIRE SPACE
MANUAL CONTROL
-LIGHTS AUTOMATICALLY TURN OFF
VACANCY (20 MINUTES OF INACTIVITY)
LEVEL BASED ON AVAILABLE SUNLIGHT
ADJUSTS DIMMING TO PROGRAMMED
-DAYLIGHT SENSOR CONTINUOUSLY
100% OUTPUT WHEN OCCUPIED
-LIGHTS AUTOMATICALLY TURN ON TO
OCCUPANCY
TOGETHER
- ALL FIXTURES ARE CONTROLLED
- ALL LIGHTS ARE DIMMABLE
LIGHTS
SEQUENCE OF OPERATION:
OC
B
C
OC
C
A
DEVICE LEGEND
DESIGNATION DESCRIPTION
A
SEE GENERAL NOTE 10.
RELAY MODULE WITH 0-10V DIMMING OUTPUT.
C
ON/OFF SMART WALL SWITCH
LONG RANGE PIR HALLWAY OCCUPANCY SENSOR
B
D
PHOTOCELL (IF WITH WINDOWS)
DAYLIGHT SENSOR - AUTOMATIC DIMMING
B
E
NOTE 2. SEE GENERAL NOTE 10.
OUTPUT. SEE SEQUENCE OF OPERATION AND
EMERGENCY RELAY PACK WITH 0-10V DIMMING
SAFE EGRESS.
VIA THE EMERGENCY RELAY PACK WILL TURN ON ALLOWING
AVAILABLE. UPON LOSS OF MAIN POWER, LIGHTS CONNECTED
LIGHT WILL OPERATE NORMALLY WHEN MAIN POWER IS 2.
ON LIGHTING PLANS.
THIS SCHEMATIC APPLIES TO THE ROOMS MARKED WITH 1.
NOTES:
SEE GENERAL NOTE 10.
OUTPUT. SEE SEQUENCE OF OPERATION AND NOTE 2.
EMERGENCY RELAY PACK WITH 0-10V DIMMING
LIGHTS CONNECTED VIA THE EMERGENCY RELAY PACK WILL TURN ON ALLOWING SAFE EGRESS.
LIGHT WILL OPERATE NORMALLY WHEN MAIN POWER IS AVAILABLE. UPON LOSS OF MAIN POWER,2.
THIS SCHEMATIC APPLIES TO THE ROOMS MARKED WITH ON LIGHTING PLANS.1.
NOTES:
GENERAL NOTE 9.
CONTROL NETWORK. SEE
TO BUILDING LIGHTING
GENERAL NOTE 9.
CONTROL NETWORK. SEE
TO BUILDING LIGHTING
1. LIGHTING CONTROL SYSTEM SHOWN HERE IS TYPICAL.
ALTERNATIVES TO SYSTEM SHOWN SHALL MEET ALL
SEQUENCE OF OPERATIONS PER ROOM. CONTRACTOR SHALL
PROVIDE MODIFICATIONS AND ADDITIONS TO LIGHTING
CONTROL SYSTEM DESIGN FOR ANY SUBSTITUTIONS.
2. PLANS SHOWN HERE ARE TYPICAL ROOM EXAMPLES AND
SCHEMATIC IN NATURE. SEE NOTE 1 WITHIN CELL(S) FOR
ACTUAL PROJECT ROOMS APPLICABLE TO SCENERIO. SEE
LIGHTING PLANS FOR ACTUAL FIXTURE, SMART SWITCH, AND
OCCUPANCY/DAYLIGHT SENSOR LOCATIONS AND SWITCHING
REGIONS. SEE POWER PLANS FOR CONTROLLED (ARC)
RECEPTACLE LOCATIONS. RELAY PACKS AND DIGITAL SMART
SWITCH FUNCTIONS NOT SHOWN ON PROJECT PLANS FOR
SIMPLICITY.
3. DIAGRAM LEGENDS SHOWN APPLY TO THIS DRAWING ONLY.
4. PROVIDE (1) CATEGORY 5E CABLE BETWEEN EACH SMART
DEVICE.
5. FIELD ROUTE LIGHTING CIRCUIT FOR LIGHT FIXTURES
OPERATED VIA RELAY MODULES THROUGH THE DIMMING
RELAY MODULE PRIOR TO GOING TO FIXTURES.
6. PROVIDE 2/C #16 SHIELDED CABLE FOR 0-10V DIMMING
CIRCUIT, FIELD ROUTED BETWEEN DIMMING RELAY MODULE
AND FIXTURES.
7. RELAY PACK(S) MOUNT ABOVE CEILING ON JUNCTION BOX
KNOCK OUT.
8. USE A DIMMING RELAY MODULE FOR EACH LIGHTING ZONE.
9. SEE LIGHTING DETAILS FOR BUILDING-WIDE NETWORK
DIAGRAM(S).
10. IF ROOM IS LOCATED WITHIN THE BSL-2 OR BSL-3 LAB
BARRIER, LOCATE RELAY OUTSIDE OF BARRIER.
CONTRACTOR MAY COMBINE RELAYS INTO MULTI-RELAY
PANELS, IF DESIRED. ALL CONDUIT ENTERING BSL RATED
SPACES SHALL HAVE A CONDUIT SEALING COMPOUND IN A
SEAL-OFF FITTING OUTSIDE THE RATED SPACE. CHICO-STYLE
HARDENING SEALANT SHALL NOT BE USED.
D
E
DEVICE LEGEND
DESIGNATION
B
DESCRIPTION
INTEGRATED PASSIVE INFRARED OCCUPANCY SENSOR
ON/OFF SMART WALL SWITCH,
- ON/OFF CONTROL OF LIGHTS
MANUAL CONTROL
-LIGHTS AUTOMATICALLY TURN OFF
VACANCY (20 MINUTES OF INACTIVITY)
FOR 100%
-LIGHTS COME ON AUTOMATICALLY
OCCUPANCY
TOGETHER
- ALL FIXTURES ARE CONTROLLED
WIRING
- ALL LIGHTS ARE DIMMABLE VIA 0-10V
LIGHTS
SEQUENCE OF OPERATION:
B
A
A
DEVICE LEGEND
DESIGNATION
A
DESCRIPTION
ON/OFF BI-LEVEL SMART WALL SWITCH
- ON/OFF CONTROL OF LIGHTS
MANUAL CONTROL
-LIGHTS AUTOMATICALLY TURN OFF
VACANCY (20 MINUTES OF INACTIVITY)
FOR 100%
-LIGHTS MUST BE MANUALLY TURNED ON
50%
-LIGHTS COME ON AUTOMATICALLY TO
OCCUPANCY
TOGETHER
- ALL FIXTURES ARE CONTROLLED
WIRING
- ALL LIGHTS ARE DIMMABLE VIA 0-10V
LIGHTS
SEQUENCE OF OPERATION:
B
B
A
DUAL TECHNOLOGY OCCUPANCY SENSORC
C
RELAY POWER MODULE. SEE GENERAL NOTE 10.
OUTPUT. SEE GENERAL NOTE 10.
PRE-PROGRAMMED TO ENERGIZE AT 50% INITIAL LIGHT
RELAY POWER MODULE WITH 0-10V DIMMING OUTPUT,
GENERAL NOTE 9.
CONTROL NETWORK. SEE
TO BUILDING LIGHTING
GENERAL NOTE 9.
CONTROL NETWORK. SEE
TO BUILDING LIGHTING
DEVICE LEGEND
DESIGNATION DESCRIPTION
SENSOR NOT SHOWN ON PLANS
INTEGRATED PASSIVE INFRARED SENSOR IF CEILING
ON/OFF BI-LEVEL SMART WALL SWITCH OR WITH
EMERGENCY RELAY PACK WILL TURN ON
EMERGENCY LIGHTING CIRCUIT AND
-LIGHTS CONNECTED TO THE
EMERGENCY POWER OUTAGE
LIGHTS
- ON/OFF & RAISE/LOWER CONTROL OF
MANUAL CONTROL
FOR HVAC/BMS SYSTEM
-ROOM CHANGES TO VACANT STATE
-LIGHTS AUTOMATICALLY TURN OFF
VACANCY (20 MINUTES OF INACTIVITY)
FOR HVAC/BMS SYSTEM
-ROOM CHANGES TO OCCUPIED STATE
ON FOR 100%
-LIGHTS MUST BE MANUALLY TURNED
50%
-LIGHTS COME ON AUTOMATICALLY TO
OCCUPANCY
TOGETHER
- ALL FIXTURES ARE CONTROLLED
WIRING
- ALL LIGHTS ARE DIMMABLE VIA 0-10V
LIGHTS
SEQUENCE OF OPERATION:
B
LIGHTS CONNECTED VIA THE EMERGENCY RELAY PACK WILL TURN ON ALLOWING SAFE EGRESS.
LIGHT WILL OPERATE NORMALLY WHEN MAIN POWER IS AVAILABLE. UPON LOSS OF MAIN POWER,2.
THIS SCHEMATIC APPLIES TO THE ROOMS MARKED WITH ON LIGHTING PLANS.1.
NOTES:
A
C
DUAL TECHNOLOGY OCCUPANCY SENSOR
LIGHT OUTPUT. SEE GENERAL NOTE 10.
PRE-PROGRAMMED TO ENERGIZE AT 50% INITIAL
RELAY MODULE WITH 0-10V DIMMING OUTPUT,
NOTE 2. SEE GENERAL NOTE 10.
OUTPUT. SEE SEQUENCE OF OPERATION AND
EMERGENCY RELAY PACK WITH 0-10V DIMMING
GENERAL NOTE 9.
CONTROL NETWORK. SEE
TO BUILDING LIGHTING
A
B
C
D
D
GENERAL NOTES:
SCHEMATIC LEGEND:
CAT-5e CABLE
LINE VOLTAGE
0-10VDC WIRES
LINE FEED
EMERGENCY CIRCUIT
EMERGENCY FIXTURE
LIGHTING CONTROL SCHEMATIC PLAN -
SMALL STORAGE ROOM
LIGHTING CONTROL SCHEMATIC PLAN -
LARGE STORAGE ROOM
LIGHTING CONTROL SCHEMATIC PLAN -
RESTROOMS
LIGHTING CONTROL SCHEMATIC PLAN -
CORRIDORS
LIGHTING CONTROL SCHEMATIC PLAN -
LAB SUPPORT
A
THIS SCHEMATIC APPLIES TO THE ROOMS MARKED WITH ON LIGHTING PLANS.1.
NOTES:
B
THIS SCHEMATIC APPLIES TO THE ROOMS MARKED WITH ON LIGHTING PLANS.1.
NOTES:
C
D
E
F
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
SHEET 2
EL501 0
EMERGENCY RELAY PACK WILL TURN ON
EMERGENCY LIGHTING CIRCUIT AND
-LIGHTS CONNECTED TO THE
EMERGENCY POWER OUTAGE
- ON/OFF CONTROL OF ENTIRE SPACE
MANUAL CONTROL
OUTPUT TO 50%
-LIGHTS AUTOMATICALLY REDUCE
VACANCY (20 MINUTES OF INACTIVITY)
100% OUTPUT WHEN OCCUPIED
-LIGHTS AUTOMATICALLY TURN ON TO
OCCUPANCY
OCCUPIED
LIGHT OUTPUT AT ALL TIMES UNTIL
-ALL STAIRWELL LIGHTS REMAIN AT 50%
ZONE ARE CONTROLLED TOGETHER
- ALL FIXTURES WITHIN OCCUPANCY
- ALL LIGHTS ARE DIMMABLE
LIGHTS
SEQUENCE OF OPERATION:
A
DEVICE LEGEND
DESIGNATION DESCRIPTION
ON/OFF SMART WALL SWITCH
PASSIVE INFRARED EXTENDED RANGE OCCUPANCY SENSOR (MAY BE INTEGRAL TO FIXTURE)
B
AND NOTE 2.
EMERGENCY RELAY PACK WITH 0-10V DIMMING OUTPUT. SEE SEQUENCE OF OPERATION
GENERAL NOTE 9.
CONTROL NETWORK. SEE
TO BUILDING LIGHTING
SCHEMATIC PLANS, SEE DRAWING EL500.
FOR GENERAL NOTES AND LEGEND FOR LIGHTING CONTROL 1.
A
C
B
C
DEVICE LEGEND
DESIGNATION DESCRIPTION
ON/OFF BI-LEVEL SMART WALL SWITCH
ISOLATED RELAY PACK, HVAC/BMS INTERFACE
PACK
AUTOMATIC RECEPTACLE CONTROL (ARC) RELAY
EMERGENCY RELAY PACK WILL TURN ON
EMERGENCY LIGHTING CIRCUIT AND
-LIGHTS CONNECTED TO THE
EMERGENCY POWER OUTAGE
LIGHTS
- ON/OFF & RAISE/LOWER CONTROL OF
MANUAL CONTROL
-ARC ENABLED RECEPTACLES TURN OFF
FOR HVAC/BMS SYSTEM
-ROOM CHANGES TO VACANT STATE
-LIGHTS AUTOMATICALLY TURN OFF
VACANCY (20 MINUTES OF INACTIVITY)
LEVEL BASED ON AVAILABLE SUNLIGHT
ADJUSTS DIMMING TO PROGRAMMED
-DAYLIGHT SENSOR CONTINUOUSLY
FOR HVAC/BMS SYSTEM
-ROOM CHANGES TO OCCUPIED STATE
-ARC ENABLED RECEPTACLES TURN ON
ON FOR 100%
-LIGHTS MUST BE MANUALLY TURNED
50%
-LIGHTS COME ON AUTOMATICALLY TO
OCCUPANCY
TOGETHER
- ALL FIXTURES ARE CONTROLLED
WIRING
- ALL LIGHTS ARE DIMMABLE VIA 0-10V
LIGHTS
SEQUENCE OF OPERATION:
B C
E
A
ARC
D
DUAL TECHNOLOGY OCCUPANCY SENSOR
PHOTOCELL FOR ROOMS WITH WINDOWS
DAYLIGHT SENSOR - AUTOMATIC DIMMING
LIGHT OUTPUT
PRE-PROGRAMMED TO ENERGIZE AT 50% INITIAL
RELAY MODULE WITH 0-10V DIMMING OUTPUT,
NOTE 2.
OUTPUT. SEE SEQUENCE OF OPERATION AND
EMERGENCY RELAY PACK WITH 0-10V DIMMING
GENERAL NOTE 9.
CONTROL NETWORK. SEE
TO BUILDING LIGHTING
A
B
E
C
D
F
G
F
G
GENERAL NOTES:
LIGHTING CONTROL SCHEMATIC PLAN -
BREAK ROOM
LIGHTING CONTROL SCHEMATIC PLAN -
STAIRWELLS
G
LIGHTS CONNECTED VIA THE EMERGENCY RELAY PACK WILL TURN ON ALLOWING SAFE EGRESS.
LIGHT WILL OPERATE NORMALLY WHEN MAIN POWER IS AVAILABLE. UPON LOSS OF MAIN POWER,2.
THIS SCHEMATIC APPLIES TO THE ROOMS MARKED WITH ON LIGHTING PLANS.1.
NOTES:
H D
O W
N
DEVICE LEGEND
DESIGNATION DESCRIPTION
SEE NOTE 3.
ON/OFF RAISE/LOWER SMART WALL SWITCH.
WILL TURN ON.
LIGHTING CIRCUIT AND EMERGENCY RELAY PACK
-LIGHTS CONNECTED TO THE EMERGENCY
EMERGENCY POWER OUTAGE
- ON/OFF, RAISE/LOWER
MANUAL CONTROL
-NONE
AUTOMATIC CONTROL
TOGETHER
- ALL FIXTURES IN EACH ZONE ARE CONTROLLED
LIGHTS
SEQUENCE OF OPERATION:
B
SWITCH
BACTERIA ID ROOM 171 REQUIRES MULTI-ZONE ON/OFF/RAISE/LOWER SMART WALL 3.
SAFE EGRESS.
POWER, LIGHTS CONNECTED VIA THE EMERGENCY RELAY PACK WILL TURN ON ALLOWING
LIGHT WILL OPERATE NORMALLY WHEN MAIN POWER IS AVAILABLE. UPON LOSS OF MAIN 2.
THIS SCHEMATIC APPLIES TO THE ROOMS MARKED WITH ON LIGHTING PLANS.1.
NOTES:
C
GENERAL NOTE 10.
RELAY MODULE WITH 0-10V DIMMING OUTPUT. SEE
A
SEE GENERAL NOTE 10.
OUTPUT. SEE SEQUENCE OF OPERATION AND NOTE 2.
EMERGENCY RELAY PACK WITH 0-10V DIMMING
A
B
C
LIGHTING CONTROL SCHEMATIC PLAN -
LAB SPACE
J
SCHEMATIC LEGEND:
CAT-5e CABLE
LINE VOLTAGE
0-10VDC WIRES
LINE FEED
EMERGENCY CIRCUIT
EMERGENCY FIXTURE
REGULAR PANEL
POWER PANEL
EMERGENCY
INVERTER/
FIXTURES SCHEMATIC
LINE VOLTAGE SWITCHED ROOMS WITH EMERGENCY
DEVICE
CONTROL
LIGHTS
ROOM
REGULAR
LIGHTS
EMERGENCY
DESIGNATED
RLY-SW-2 RLY-SW-2
POWER
REGULAR UTILITY
POWER
REGULAR UTILITY
SHOWN
NEUTRAL NOT
RLY-SW-2
GENERAL NOTE 9.
CONTROL NETWORK. SEE
TO BUILDING LIGHTING
LIGHTS CONNECTED VIA THE EMERGENCY RELAY PACK WILL TURN ON ALLOWING SAFE EGRESS.
LIGHT WILL OPERATE NORMALLY WHEN MAIN POWER IS AVAILABLE. UPON LOSS OF MAIN POWER,2.
THIS SCHEMATIC APPLIES TO THE ROOMS MARKED WITH ON LIGHTING PLANS.1.
NOTES:
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
SHEET 3
EL502 0
SCHEMATIC PLANS, SEE DRAWING EL500.
FOR GENERAL NOTES AND LEGEND FOR LIGHTING CONTROL 1.
GENERAL NOTES:
NETWORK
GATEWAY
MAIN
LIGHTING
CONTROL
COMPUTER
(NOTE 2)
TO BMS SYSTEM
CABLE (TYP)
CATEGORY 5e
(NOTE 2)
COMMUNICATION LINK
BACNET (-IP OR -MS/TP)
GATEWAY PER FLOOR
ONE NETWORK
BRIDGE
TO NEXT
ROOMS
BRIDGE PER 7
ONE NETWORK
RELAY PACK
POWER DIMMING
120V OR
277V
PS
BRIDGE
SMART WALL STATION
LIGHT (TYP)
OC
DS
OC
DS
BACNET
INTERFACE
(NOTE 2)
120V OR
277V
PS
BRIDGE
120V OR
277V
PS
SMART WALL STATION
RELAY PACK
POWER DIMMING
ROOM 1 ROOM 2
TYPICAL LIGHTING CONTROL NETWORK
DIAGRAM - GENERIC
1. SYSTEM SHOWN IS A TYPICAL LIGHTING CONTROL
NETWORK DIAGRAM. WIRING AND OPERATING
PARAMETERS MAY VARY AND INSTALLED COST SHALL BE
SAME AS BASIS OF DESIGN OR LESS.
2. SYSTEM SHALL UTILIZE A BACNET INTERFACE MODULE FOR
DIRECT COMMUNICATION OF OCCUPANCY INTO THE BMS
SYSTEM.
3. WHEN LIGHT OVERRIDE IS REQUIRED BY BMS SYSTEM, THE
LIGHTING CONTROL NETWORK WITH BRIDGES AND
GATEWAYS IS REQUIRED TO BE CONNECTED TO BACNET
INTERFACE AS SHOWN. THE BACNET INTERFACE SHALL
COMMUNICATE BY BACNET PROTOCOL TO THE SELECTED
BUILDING MANAGEMENT SYSTEM (BMS) FOR BMS SYSTEM
TO CONTROL ALL BUILDING LIGHTING AT THE ROOM
CONTROLLER LEVEL FROM THE POWER DIMMING RELAY.
4. POWER SUPPLIES ARE REQUIRED FOR THE BRIDGES,
GATEWAYS, AND BACNET INTERFACE. CONTRACTOR SHALL
USE 120V OR 277V CLOSEST LIGHT CIRCUIT AT
CONTRACTORS DISCRETION WITH NON-SWITCHED INPUT
TO POWER SUPPLY. LOW VOLTAGE WIRING INPUT FROM
POWER SUPPLY TO EQUIPMENT SHOWN SUCH AS BACNET
INTERFACE, GATEWAYS, AND BRIDGES SHALL BE DEFINED
BY MANUFACTURER. IN ALL CASES THE DISTANCE FROM
POWER SUPPLY TO POWERED DEVICE SHALL BE
MINIMIZED.
5. ALLOWABLE QUANTITY OF BRIDGE INPUTS VARY BY
MANUFACTURER. BASIS OF DESIGN SHOWN ALLOWS 7
CATEGORY 5E INPUTS PER BRIDGE AND ONE CATEGORY 5E
PORT FOR COMMUNICATION TO GATEWAY OR NEXT
BRIDGE. ACTUAL MANUFACTURER SYSTEM USED AND
WORKING SCHEMATICS SHALL BE PROVIDED AS
SUBMITTALS PRIOR TO INSTALLATION. IF COMMUNICATION
BETWEEN BRIDGES IS DIFFERENT THAN CATEGORY 5E
CABLE THIS SHALL BE CLEARLY SHOWN IN SUBMITTAL FOR
APPROVAL.
LIGHTING CONTROL NETWORK DIAGRAM - GENERIC - GENERAL NOTES:
6. CATEGORY 5E CABLE SHALL BE PLENUM RATED FOR THIS
APPLICATION AND #23 GAUGE. ALL OTHER CONTROL
WIRING SHALL ALSO BE PLENUM RATED. 120V OR 277V
CABLING SHALL BE IN METAL CONDUIT SYSTEM. ARMORED
MULTI-CONDUCTOR POWER/CONTROL CABLE IS ALSO
ACCEPTABLE FOR THE PATHS FROM POWER DIMMING
RELAYS TO FIXTURES. ALL RELAYS SHALL BE CONNECTED
TO STANDARD KNOCKOUT TYPE BOXES WITH INTEGRAL
NPT CONNECTION OF RELAY.
7. ASHRAE 90.1 REQUIREMENTS FOR 2016 REQUIRE LIGHTING
CONTROLS AS SHOWN IN LIGHTING CONTROL DETAILS AND
PLAN DRAWINGS WITH OCCUPANCY SENSOR, DAYLIGHTING
CONTROLS, BI-LEVEL CONTROL IN MOST AREAS,
DAYLIGHTING WHERE SHOWN WITH WINDOW AREAS, AND
CORRIDORS AND RESTROOMS TO HAVE OCCUPANCY
SENSOR WITH ON/OFF SMART WALL STATIONS. SEE
SPECIFIC SCHEMATICS AND/OR SEQUENCE OF
OPERATIONS FOR ROOM REQUIREMENTS.
8. EACH LED FIXTURE IN SPACES SHALL HAVE A 0-10V
DIMMING DRIVER AS SHOWN IN THE LIGHT FIXTURE
SCHEDULE. ALL ROOM CONTROLLERS SHALL BE POWER
DIMMING RELAYS WHICH WILL ALLOW 0-10 VOLT DIMMING
OUTPUTS AND CAN BE USED FOR BI-LEVEL OR
DAYLIGHTING SETTINGS AS PROGRAMMED WITH
CONTROLLERS. SEE ROOM SCHEMATIC DETAILS AND/OR
SEQUENCE OF OPERATIONS PER ROOM.
9. ALL SENSORS, INCLUDING SMART WALL STATIONS, ARE
POWERED BY CATEGORY 5E CABLING FROM
DIMMING/POWER RELAY. EACH SENSOR SHALL HAVE IN
AND OUT 8P8C PORTS TO ALLOW DAISY CHAINING DEVICES
AND EACH DEVICE IS AUTOMATICALLY RECOGNIZED BY THE
ASSOCIATED POWER DIMMING RELAY. CONTRACTOR TO
VERIFY, BASED ON SYSTEM PROVIDED, HOW MANY
DEVICES CAN BE ON EACH CATEGORY 5E CABLE BEFORE A
SECOND POWER DIMMING RELAY IS REQUIRED.
10. POWER DIMMING RELAYS ARE POWERED BY 120V OR 277V
LIGHTING CIRCUITS FOR ASSOCIATED SPACE. EACH
POWER DIMMING RELAY UTILIZES A LINE OUT THAT IS THE
PHASE CONDUCTOR TO ASSOCIATED LIGHT FIXTURES. THE
0-10V DIMMING CIRCUIT IS ALSO ROUTED TO EACH FIXTURE
WITH A #16TSP CABLE FROM THE RELAY FOR DIMMING
CONTROL. ARMORED MULTI-CONDUCTOR POWER/CONTROL
CABLE IS ACCEPTABLE. IF CONTROL MANUFACTURER
MAKES A MODULE TO INSTALL DIRECTLY ON A LIGHT
FIXTURE FOR CONTROL BY CATEGORY 5E CABLE,
CONTRACTOR MAY USE THIS MODULE SYSTEM AND DELETE
THE 0-10V WIRING REQUIREMENT.
11. THERE ARE VARIOUS SMART WALL STATION OPTIONS. THE
SWITCHING ZONES ARE SHOWN ON THE LIGHTING PLANS.
WHERE MULTIPLE SWITCH ZONES ARE REQUIRED THERE
WILL BE A DEDICATED POWER DIMMING RELAY FOR EACH
ZONE THAT IS CONTROLLED THROUGH COMMON
OCCUPANCY SENSOR(S). SMART WALL STATIONS CAN BE
EITHER SINGLE ZONE OR COMBINED UP TO FOUR ZONES IN
ONE DEVICE. IF MORE THAN ONE SWITCH ZONE IS
REQUIRED PER SPACE, CONTRACTOR MAY PROVIDE A
SINGLE SMART WALL STATION THAT CAN COMBINE UP TO
FOUR ZONES WITH EITHER ON/OFF, RAISE/LOWER, OR
RAISE/LOWER WITH DIMMING FUNCTIONS SHOWN IN THE
SPACES ON THE LIGHTING PLANS, ROOM SCHEMATICS,
AND SEQUENCE OF OPERATIONS PER ROOM TYPE.
12. CONTRACTOR SHALL USE CONDUIT WITH INSULATED
BUSHINGS FOR SMART WALL STATION LOCATIONS TO GET
CATEGORY 5E CABLE STUBBED UP INTO PLENUM SPACE.
SPECIFICATIONS CALL FOR FULL CONDUIT SYSTEM BUT
THE CATEGORY 5E CABLE IS PLENUM RATED AND WITH
8P8C CONNECTIONS AT RELAYS AND EQUIPMENT, A FULL
CONDUIT SYSTEM FOR THE CATEGORY 5E CABLE MAY NOT
BE POSSIBLE.
13. THE BRIDGE SHOWN IN THIS BASIS OF DESIGN HAS 8-8P8C
CONNECTIONS AND A BRIDGE WILL BE REQUIRED FOR
EVERY 7 ROOMS IN THE AREA. THE EIGHTH PORT WILL BE
USED TO CONNECT BRIDGES TOGETHER WITH CATEGORY
5E CABLE TO DAISY CHAIN ANOTHER GROUP OF ROOMS, IF
NEEDED. MULTIPLE BRIDGES WILL BE CONNECTED TO
EACH OF THE ROOM CONTROLLERS WITH CATEGORY 5E
CABLE. ONE OF THE CONNECTED BRIDGES THAT IS
NETWORKED IS IN TURN CONNECTED BY CATEGORY 5E
CABLE TO A GATEWAY (ONE PER FLOOR) THAT ULTIMATELY
CONNECTS TO A MAIN LIGHTING CONTROL COMPUTER TO
COMPLETE THE NETWORK. IN THE CASE OF A LARGE
BUILDING (31 ROOMS OR MORE), AND THE BMS REQUIRES
DIRECT COMMUNICATIONS OF OCCUPANCY FOR HVAC, THE
GATEWAYS WILL BE CONNECTED TO A SINGLE BACNET
INTERFACE MODULE IN THE BUILDING THAT WILL RESIDE
ON THE NETWORK SO THAT THE MODULE CAN
COMMUNICATE BY BACNET TO THE BMS SYSTEM. THE
BACNET MODULE AND FIRST FLOOR GATEWAY SHALL BE
PLACED BY CONTRACTOR NEAR THE BMS HEAD END
CONTROLLER. THE BACNET COMMUNICATION SHALL BE
COORDINATED WITH BMS MANUFACTURER FOR CONTROL
CAPABILITY OF ALL ROOM CONTROLLERS OR SELECTED
CONTROLLERS THROUGH THE BMS SYSTEM.
14. THE NETWORK DIAGRAM REFLECTS GENERAL CONDITIONS
AND IS NOT REPRESENTATIVE TO ACTUAL COUNTS OF
DEVICES REQUIRED. THE ACTUAL NETWORK DIAGRAM
SHALL BE PROVIDED BY CONTRACTOR IN SUBMITTAL
DRAWINGS BY CONTROL SYSTEM MANUFACTURER.
15. THE POWER DIMMING RELAYS AND AUXILIARY RELAYS MAY
HAVE THREADED CONNECTOR INTO STANDARD KNOCKOUT
BOXES ABOVE CEILING FOR CONDUIT CONNECTIONS TO
LIGHT FIXTURES AND CONTROLS.
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
ELECTRICAL LIGHT
FIXTURE SCHEDULE
EL600 0
MAY 31, 2019
001B
BM
K
R
E
D
A
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
001A
001B
AIMTS
CRAWL SPACE
SS
SS
SS
SS
SS
F
F
E
E
001A
B
M
K R
E
SP (PENTHOUSE) UP
4" FDC UP
S P
B S
M N
T
FDC
S P
G R
N D
SP (PENT)
TH
4" TH UP
1 2 3 4 5
MECHANICAL
C
D
E
F
G
UP
(GROUND)
SP
EXST FIRE SERVICE
4" FS (GROUND)
4" FS (CRAWL SPACE)
4" FS (PENTHOUSE)
AIMFS
CRAWL SPACE ELECTRICAL
SPECIAL SYSTEMS PLAN
ES101 0
1/8"=1'-0"
CRAWL SPACE COMMUNICATIONS, SECURITY, AND FIRE ALARM PLAN
21'-0"21'-0"
A.5
12.5
10'-6"
10'-6"
11.5
9'-0"
13 14
A.4
A.3
A.2
NORTH
FOR NOTES SEE DRAWING ES111.1.
NOTES:
A.1
21'-0"
21'-0"
10'-6"
18.5
9'-0"
FLOW/TAMPER SWITCHES BY OTHERS.
MONITOR MODULES. SEE SHEETS MF101 AND MF500.
TAMPER SWITCHES ARE LOCATED IN CRAWL SPACE. PROVIDE
ARE LOCATED IN EXISTING BUILDING 21 BASEMENT. THREE NEW
THREE NEW TAMPER SWITCHES AND THREE NEW FLOW SWITCHES 2.
WAP BY OTHERS. MOUNT AT 6'-0" ABOVE FINISHED FLOOR.
SINGLE CAT-6A OUTLET FOR WIRELESS ACCESS POINT (WAP).1.
KEYNOTES:
AFF (TYP)
MOUNT AT 6'-0"
SECURITY, AND FIRE ALARM PLAN
EXISTING BASEMENT COMMUNICATIONS,
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
FEC
COMM
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
BREAK ROOM
OFFICE OFFICEOFFICE
OFFICE
114 119116 120
OFFICE OFFICE
E
X
I
T
I
N
W
W
Y
STAIR
COPY
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
STORAGE
OFFICE
HALLWAY
H A
L L
W A
Y
H A
L L
W A
Y
SHOWER 1
CLEAN
GOWN 1
ENTRANCE 1
ARCHIVE
PCR
WGS
GOWN
(POST AMP)
GELS
PCR/SEQUENCING
MASTER MIX
TEMPLATE
GOWN
GOWN
(PRE AMP)
EXTRACTION
DNA STORAGE
LINEAR EQUIPMENT ROOM
PROCESSING 3
WASH
CULTURE
TISSUE
PREP
INCUBATION
167A
AUTOCLAVE
JAN
COLD ROOM
BACTERIA ID
BRUCELLA
COLD ROOM
AMBIENT
STORAGE
DIRTY
GOWN 1
TOILET
TOILET
ENTRANCE 2
CLEAN GOWN 2
DIRTY GOWN 2
SHOWER 2
PHENOL
ARCHIVE HOLDING
ACCESSIONING/
LOGIN
BSL-3 SIDE
ACCESSIONING/
LOGIN
BSL-2 SIDE
AIR LOCK
MAIN CORRIDOR
PROCESSING 1
PROCESSING 2
E X I S T I N G H A L L
STORAGE
167B
AUTOCLAVE
GROUND LEVEL CABLE TRAY PLAN
ES110 0
GROUND LEVEL COMMUNICATIONS CABLE TRAY PLAN
NORTH11.5 12 12.5 13 14 15 16 17 18 18.5
A.5
A.4
A.3
A.2
A.1
JJ
BLDG 21
WALKWAY
D
CEILING INSTALLATION.
LIGHTING, AND FIRE ALARM CABLES SHALL BE TESTED PRIOR TO
ELECTRICAL, COMMUNICATIONS, SECURITY ACCESS CONTROL,
CABLE TRAY IN BSL-3 AREA IS A PERMANENT INSTALLATION. ALL 4.
INSTALLATION OF ACCESS PANELS.
COORDINATE WITH MECHANICAL HVAC DIFFUSER LOCATIONS FOR 3.
TRANSITION THROUGH BSL BARRIER.
SEE DETAILS ON ES500 SERIES DRAWINGS FOR CABLE TRAY 2.
SEALANT SHALL NOT BE USED.
FITTING OUTSIDE THE BSL-3 SPACE. CHICO-STYLE HARDENING
SHALL BE SEALED WITH A CONDUIT SEALING COMPOUND IN SEAL-OFF
CONDUITS FROM CABLE TRAY ENTERING BSL-3 LABORATORY SPACES
NO CABLE TRAY IS TO PENETRATE BSL-3 LABORATORY SPACE. 1.
NOTES:
19 20
B
B.6
C
(TYP)
ABOVE CEILING
BOTTOM OF TRAY
TRAY; 1'-0" TO
18"X6" CABLE
SEE NOTE 2
SEE NOTE 2
SEE NOTE 2
PANEL (TYP)
AIR TIGHT ACCESS
2'X2' GASKETED,
SEE NOTE 4
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
111 112 113 114110109
G
G
G
SS
GGGGG
P P
B
K
M
KE
SS
SS
SS
V
SS
V
V
SS
SS
V
P
SS
SS
SS
G
G
G
G
P
B
M
K E
SS
K
B
M
KK
E
J
J
J
J
SS
SS
SS
J
J
V
SHOWER 1
CLEAN
GOWN 1
ENTRANCE 1
ARCHIVE
BACTERIA ID
BRUCELLA
COLD ROOM
DIRTY
GOWN 1
TOILET
TOILET
ENTRANCE 2
CLEAN GOWN 2
DIRTY GOWN 2
SHOWER 2
MAIN CORRIDOR
JAN
COLD ROOM
AMBIENT
STORAGE
PHENOL
OFFICE
OFFICE
OFFICE
BREAK ROOM
OFFICE OFFICECOPY OFFICEOFFICE
OFFICE
OFFICE
114109 111110
J
HALLWAY
HALLWAY
KEYPLAN
1 2
3 4
5 68
GROUND LEVEL ELECTRICAL
SPECIAL SYSTEMS PLAN - AREA 1
ES111 0
GROUND LEVEL COMMUNICATIONS, SECURITY, AND FIRE ALARM PLAN - AREA 1
MATCH LINE - FOR CONT SEE DWG ES113
M A
T C
H L
IN
E F
O R C
O N
T S
E E D
W G E
S
A.5
12.51211.5 13 14
A.4
A.3
A.2
NORTH
REQUIRES DUPLEX RECEPTACLE. SEE DWG EP111.
2" RACEWAY TO CABLE TRAY FROM JUNCTION BOX FOR CABLES.
PROVIDE PROJECTOR MOUNT CHIEF CMS-445N, OR EQUAL. PROVIDE 5.
ON CEILING. WAP PROVIDED BY OTHERS.
PROVIDE SURFACE MOUNTED SINGLE CAT 6 DATA OUTLET FOR WAP 4.
PROVIDED BY OTHERS.
PROVIDE SINGLE CAT 6 DATA OUTLET ABOVE CEILING FOR WAP. WAP 3.
ABOVE FINISHED FLOOR IN HALLWAY.
CABLE. TO FEED FUTURE WALL-MOUNTED ROOM WIZARD AT 4'-4"
PROVIDE JUNCTION BOX ABOVE CEILING WITH 10'-0" COILED CAT 6
LOCATION OF FUTURE STEELCASE ROOM WIZARD (BY OTHERS). 2.
FREEZER IN ROOM 175.
FINISHED FLOOR FOR FUTURE SECURITY CONNECTIONS FOR
PROVIDE 8" X 12" JUNCTION BOX WALL MOUNTED AT 9'-0" ABOVE 1.
KEYNOTES:
FLOOR BOX. SEE DWG EP111
DATA/POWER COMBINATION
FOR PROJECTOR.
MOUNTED ABOVE CEILING
12"X12"X12" JUNCTION BOX
CEILING AND WALL INSTALLATION.
ALL CABLES INSTALLED IN BSL-3 AREAS SHALL BE TESTED PRIOR TO 6.
VIA FIRE ALARM SPEAKERS.
INTERCONNECTED TO FIRE ALARM AND NOTIFICATION SYSTEM
MASS NOTIFICATION SYSTEM (MNS) SYSTEM SHALL BE 5.
AND LAB SPACE DRAWINGS.
DIRECTLY ABOVE BACKSPLASH. COORDINATE WITH ARCHITECTURAL
MOUNT DUAL COMPARTMENT SURFACE MOUNTED RACEWAY
SHALL BE HORIZONTAL MOUNTED 3'-6" AFF TO BOTTOM OF PLATE.
DATA OUTLET LOCATIONS SHOWN WHERE COUNTERTOPS INSTALLED 4.
FOR RISER DIAGRAMS SEE ES600 SERIES DRAWINGS.3.
FOR DETAILS SEE ES500 SERIES DRAWINGS.2.
DRAWING GG10.
FOR COMMUNICATION, SECURITY AND FIRE ALARM LEGEND, SEE 1.
NOTES:
182-CAM06
176-CAM03
175-CAM05
173-CAM04
MOUNT AT 3'-6" AFF
OUTLETS HORIZONTAL
THIS ROOM ALL DATA
SEE DWG EP111
LOCATION
MOUNT
PROJECTOR
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
SS
SS
B
M
KK
E
B
M
K R
E
B
M
P
P
P
B M
R E
K
V
R K
B
M
F
V
KK
E
SS
SS
SS
SS
G G G G G G G
SS
SS
SS
P
SS
SS
E
SS
SS
PROCESSING 3166
WASH
CULTURE
TISSUE
PREP
INCUBATION
PHENOL
ARCHIVE HOLDING
ACCESSIONING/
LOGIN
BSL-3 SIDE
ACCESSIONING/
LOGIN
BSL-2 SIDE
AIR LOCK
MAIN CORRIDOR
PROCESSING 1
PROCESSING 2
OFFICEOFFICE OFFICE OFFICEOFFICE OFFICE OFFICE
STAIR
STORAGE
OFFICE
115 117 118 119116 120
J
HALLWAY
HALLWAY
115 117116 118 119 120
125A
125B
KEYPLAN
1 2
3 4
SPECIAL SYSTEMS PLAN - AREA 2
ES112 0
MAY 31, 2019
NC VEEN
GROUND LEVEL COMMUNICATIONS, SECURITY, AND FIRE ALARM PLAN - AREA 2
MATCH LINE - FOR CONT SEE DWG ES114
M A
T C
H L
IN
E F
O R C
O N
T S
E E D
W G E
S
A.5
18 18.5 17.11716
A.4
A.3
A.2
19 17.720
DD
EE
FF
ON CEILING. WAP PROVIDED BY OTHERS.
PROVIDE SURFACE MOUNTED SINGLE CAT 6 DATA OUTLET FOR WAP 2.
PROVIDED BY OTHERS.
PROVIDE SINGLE CAT 6 DATA OUTLET ABOVE CEILING FOR WAP. WAP 1.
KEYNOTES:
FOR NOTES SEE DRAWING ES111.1.
NOTES:
190-CAM01
WALK-CAM07
3'-6" AFF THIS ROOM, UNO
HORIZONTAL MOUNT AT
ALL DATA OUTLETS
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
160B
1A-169
1A-170 1A-172
1A-171 1A-173
1A-174 1A-176
1A-175
1A-189
1A-196
1A-202
1A-203
W
J1
GB
J1
GB
G
P J
G
G P
SS
SS
SS
SS
SS
SS
SS
P P P
SS
B
K
R
B
M
K
B
M
K
B
M
K
B
M
K
B
K
M
E R
V
PCR
BACTERIA ID
LINEAR EQUIPMENT ROOM
COLD ROOM
WGS
GOWN
(POST AMP)
GELS
PCR/SEQUENCING
MASTER MIX
TEMPLATE
OFFICE
OFFICE
OFFICE
OFFICE
AUTOCLAVE
J
B
M
K
J
J
J
J J J J J J
J
J
JJJJJ
J
J J
J
R
R
R
R
R
PCR
BACTERIA ID
LINEAR EQUIPMENT ROOM
COLD ROOM
WGS
GOWN
(POST AMP)
GELS 153
PCR/SEQUENCING
MASTER MIX
TEMPLATE
OFFICE
OFFICE
OFFICE
OFFICE
EXISTING HALL
HALLWAY
KEYPLAN
1 2
3 4
SPECIAL SYSTEMS PLAN - AREA 3
ES113 0
GROUND LEVEL COMMUNICATIONS, SECURITY, AND FIRE ALARM PLAN - AREA 3
A
T C
H L
IN
E F
O R C
O N
T S
E E D
W G E
S
1512.51211.5 13 14
A.1
A.2
MATCH LINE - FOR CONT SEE DWG ES111
B
C
JACKS.
SEE DRAWING EP200 FOR ELEVATIONS SHOWING ADDITIONAL DATA 3.
CONTRACTOR TO WIRE OUTLETS.
QUAD DATA OUTLETS PROVIDED AS PART OF CASEWORK. 2.
PROVIDED BY OTHERS.
PROVIDE SINGLE CAT 6 DATA OUTLET ABOVE CEILING FOR WAP. WAP 1.
KEYNOTES:
FOR NOTES SEE DRAWING ES111.1.
NOTES:
175-CAM05
160-CAM02
MOUNT AT 3'-6" AFF
OUTLETS HORIZONTAL
THIS ROOM ALL DATA
AS REQUIRED
LOCATION PROVIDE
SERVICE DROP
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
VC-4-E
FEC
160A
1A-216 W
SS
SS
P
SS
SS
SS
SS
SS
SS
SS
V
SS
SS
SS
P
P
B
M
E
K
R
SS
B
K
M
E
B M
K
E
KK
P
R
SS
SS
SS
R
LINEAR EQUIPMENT ROOM
PROCESSING 3166
WASH
PREP
MASTER MIX
TEMPLATE
GOWN
GOWN
(PRE AMP)
EXTRACTION
DNA STORAGE
COMM
STORAGE
STORAGE
M
K
B
M
J
J
J
J
HALLWAY
J
J
J
J
J
J
J J
J
J
J
R
LINEAR EQUIPMENT ROOM
PROCESSING 3166
WASH
PREP
MASTER MIX
TEMPLATE
GOWN
GOWN
(PRE AMP)
EXTRACTION
DNA STORAGE
COMM
STORAGE
STORAGE
EXISTING HALL
LINEAR EQUIPMENT ROOM
160 124
HALLWAY
KEYPLAN
1 2
3 4
SPECIAL SYSTEMS PLAN - AREA 4
ES114 0
GROUND LEVEL COMMUNICATIONS, SECURITY, AND FIRE ALARM PLAN - AREA 4
MATCH LINE - FOR CONT SEE DWG ES112
M A
T C
H L
IN
E F
O R C
O N
T S
E E D
W G E
S
15 18 18.5 17.11716
A.2
19 17.720
FF
GG
HH
D
A.1
B
C
JJ
BLDG 21
WALKWAY
NORTH
AMEGA UNIT
R2-G5
FACP
TRANSPONDER
PANEL
4'X8'
PLYWOOD
BACKBOARD
TELECOMMUNICATIONS
GROUND BUSBAR
COMM
RACK
A
COMM
RACK
B
COMM
RACK
C
ADDITIONAL SPACE RESERVED FOR LENEL EQUIPMENT.4.
CONTRACTOR TO WIRE.
QUAD DATA OUTLET PROVIDED BY CASEWORK MANUFACTURER. 3.
ON CEILING. WAP PROVIDED BY OTHERS.
PROVIDE SURFACE MOUNTED SINGLE CAT 6 DATA OUTLET FOR WAP 2.
PROVIDED BY OTHERS.
PROVIDE SINGLE CAT 6 DATA OUTLET ABOVE CEILING FOR WAP. WAP 1.
KEYNOTES:
FOR NOTES SEE DRAWING ES111.1.
NOTES:
MOUNT AT 7'-0"
AFF FOR TV
2'X3' PLYWOOD
BACKBOARD
MOUNT AT 3'-6" AFF
OUTLETS HORIZONTAL
THIS ROOM ALL DATA
F R
O N
T
COMM RACKS, FOR
ELEVATION SEE
DWG ES510
PANEL
SECURITY
LENEL
MOUNT AT 3'-6" AFF
OUTLETS HORIZONTAL
THIS ROOM ALL DATA
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
MENS
RESTROOM
MENS
LOCKER
1103A
DATA
CORR
WOMENS
LOCKER
1105A
WOMENS
RESTROOM
SALMONELLA
SEROTYPING
REAGENTS
COLD ROOM
BI
STOR
SERO
ALTER
TEST
PARA
IDEN
PARA
PROC
1303A
W
W
W
FACP
OS2-G7-1
OS2-G7-2
KEYPLAN
1 2
3 4
SPECIAL SYSTEMS PLAN - AREA 8
ES118 0
GROUND LEVEL COMMUNICATIONS, SECURITY, AND FIRE ALARM PLAN - AREA 8
9 11
21'-0"
F
G
J
C
32'-0"
21'-0"
DRAWING ES600. SEE CONTINUATION ON DRAWING ES128.
COMM ROOM RISER DIAGRAM FOR REQUIRED CABLING ON
SPARE CONDUITS UP TO EXISTING PENTHOUSE WIREWAY. SEE
COMMUNICATIONS EXTENSIONS FOR NEW ADDITION IN THESE
FIELD ROUTE CABLING FOR FIRE ALARM, SECURITY, AND 1.
KEYNOTES:
EXST SPARE CONDUITS
TO EXST PENTHOUSE
WIREWAY ABOVE (ABOVE)
EXST SECURITY
PANEL (BELOW)
EXST FACP
FOR NOTES SEE DRAWING ES111.1.
NOTES:
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
SS
MECHANICAL
SS
30SS
SS
SS
AHU-12.2
AHU-12.1
AHU-11.2
AHU-11.1
P -1
.1
P -1
.2
EF-14.2EF-14.1
EF-108
EF-109
H X -1
.1
H X -1
.2
CND-A
ROOM
CND-B
ROOM
ROOF ABOVE
EF-200 ON
KEYPLAN
1 2
3 4
PENTHOUSE LEVEL ELECTRICAL
SPECIAL SYSTEMS PLAN - AREA 1
ES121 0
1/4" = 1'-0"
DL GEORGE
PENTHOUSE LEVEL COMMUNICATIONS, SECURITY, AND FIRE ALARM PLAN - AREA 1
MATCH LINE - FOR CONT SEE DWG ES123
M A
T C
H L
IN
E F
O R C
O N
T S
E E D
W G E
S
A.5
12.51211.5 13 14
A.4
A.3
A.2
NORTH
FOR NOTES SEE DRAWING ES111.1.
HANDLING UNITS. PROVIDE TEST STATIONS.
PROVIDE SMOKE DETECTOR FOR DUCT ON SUPPLY SIDE FOR AIR 1.
KEYNOTES:
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
B M F
SS
K
K
SS
B
SS
R E
K
B
E
V
SS
MECHANICAL
STAIR
STORAGEB
SS
SS
M M
P -1
.1
P -1
.2
P-12.1
P-12.2
WH-10.1 WH-10.2
EF-14.2
P-10.2
P-10.1
AHU-10.2
AHU-10.1
SKID
RO
RF-10.1
H X -1
.1
H X -1
.2
HX-11.1
HX-11.2
A C -1
.1
C P -1
.1
C P -1
.1
CND-A
ROOM
CND-B
ROOM
CND-A
ROOM
CND-B
ROOM
PH-10.1
KEYPLAN
1 2
3 4
SPECIAL SYSTEMS PLAN - AREA 2
ES122 0
MATCH LINE - FOR CONT SEE DWG ES124
A
T C
H L
IN
E F
O R C
O N
T S
E E D
W G E
S
A.5
18 18.5 17.11716
A.4
A.3
A.2
19 17.720
DD
EE
FF
NORTH
PENTHOUSE LEVEL COMMUNICATIONS, SECURITY, AND FIRE ALARM PLAN - AREA 2
RETURN SIDE FOR AIR HANDLING UNITS. PROVIDE TEST STATIONS.
PROVIDE SMOKE DETECTOR FOR DUCT ON SUPPLY SIDE AND 1.
KEYNOTES:
HATCH (ABOVE)
BMS ON ROOF
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
SS
SS
F
B M
K
K
E
SS
MECHANICAL
SS
SS
SS
WP
B M
K
KE
EF-14.2EF-14.1
P-13.1
P-13.2
EF-10.1 EF-10.2 EF-10.3
HRC-13.3HRC-13.2HRC-13.1
KEYPLAN
1 2
3 4
SPECIAL SYSTEMS PLAN - AREA 3
ES123 0
T C
H L
IN
E F
O R C
O N
T S
E E D
W G E
S
1512.51211.5 13 14
A.1
A.2
M A
T C
H L
IN
E F
O R C
O N
T S
E E D
W G E
S
MATCH LINE - FOR CONT SEE DWG ES121
B
C
PENTHOUSE LEVEL COMMUNICATIONS, SECURITY, AND FIRE ALARM PLAN - AREA 3
2-4" CONDUIT FIELD
ROUTED ALONG WALL
NORTH
FOR NOTES SEE DRAWING ES111.1.
NOTES:
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
SS
J
J
SS
B
SS
R E
K
B
SS
H
MECHANICAL
ELECTRICAL
SS
SS
AIM
AIM
M M
P -1
.1
P -1
.2
EF-14.2
HRU-14.1 HRC-14.2 HRC-14.3
EF-11.2EF-11.1 EF-11.3
EF-12.1 EF-12.2
EF-13.1 EF-13.2
P-10.2
P-10.1
CH-10.1
VAV-202
A C -1
.1CND-A
ROOM
CND-B
ROOM
ROOF ABOVE
EF-202 ON
KEYPLAN
1 2
3 4
SPECIAL SYSTEMS PLAN - AREA 4
ES124 0
MATCH LINE - FOR CONT SEE DWG ES122
A
T C
H L
IN
E F
O R C
O N
T S
E E D
W G E
S
15 18 18.5 17.11716
A.2
19 17.720
FF
GG
HH
D
A.1
B
C
JJ
BLDG 21
WALKWAY
NORTH
PENTHOUSE LEVEL COMMUNICATIONS, SECURITY, AND FIRE ALARM PLAN - AREA 4
2-4" CONDUIT TO
COMM ROOM BELOW
CONDUIT ACCESS
AREA TO COMM
ROOM BELOW
24"X24"X12"
JUNCTION BOX
2-4" CONDUIT
FIELD ROUTED
THROUGH WALLS
2-4" CONDUIT
FIELD ROUTED
ALONG WALL
24"X24"X12"
JUNCTION BOX
CONDUIT INSTALLATION ON DRAWING EP124.
10'-0" SPAN BETWEEN SUPPORTS. COORDINATE WITH POWER
PROVIDE SUPPORTS AS REQUIRED FOR CONDUITS, NOT EXCEEDING 1.
KEYNOTES:
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
B M
K
KE
KEYPLAN
1 2
3 4
SPECIAL SYSTEMS PLAN - AREA 7
ES127 0
PENTHOUSE LEVEL COMMUNICATIONS, SECURITY, AND FIRE ALARM PLAN - AREA 7
MATCH LINE - FOR CONT SEE DWG ES128
M A
T C
H L
IN
E F
O R C
O N
T S
E E D
W G E
S
B
C
F
9 11
21'-0"
32'-0"
21'-0"
A
2-4" CONDUIT
24"X24"X12"
JUNCTION BOX
NORTH
FOR NOTES SEE DRAWING ES111.1.
NOTES:
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
FE
ELEC
CLOSET
2A6
KEYPLAN
3 4
SPECIAL SYSTEMS PLAN - AREA 8
ES128 0
PENTHOUSE LEVEL COMMUNICATIONS, SECURITY, AND FIRE ALARM PLAN - AREA 8
9 11
21'-0"
F
MATCH LINE - FOR CONT SEE DWG ES127
G
J
C
32'-0"
21'-0"
NORTH
2-4" CONDUIT FIELD
ROUTED OVERHEAD
APPROXIMATE LOCATION OF EXST COMM
WIREWAY AND JUNCTION BOX. EXST
CONDUITS DOWN TO DATA ROOM 1403;
SEE DRAWING ES118 FOR CONTINUATION
FOR NOTES SEE DRAWING ES111.1.
NOTES:
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
0 1 2 3
AT FULL SIZE
IN
cm0 1 2 3 4 5 6 7 8
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
LIGHTNING PROTECTION PLAN
ES130 0
LIGHTNING PROTECTION PLAN
12.5 13 14 15 16 17 17.118.5
A.4
A.3
A.2
A.1
ABOVE GRADE.
ALUMINUM TO COPPER. ALUMINUM SHALL NOT BE USED WITHIN 1'-6"
BI-METALLIC CONNECTORS SHALL BE UTILIZED TO CONNECT 4.
OF EXISTING AFTER CONNECTION IS COMPLETE.
PROTECTION, INC. NEW SYSTEM SHALL MAINTAIN UL CERTIFICATION
LIGHTNING PROTECTION SYSTEM SHALL BE BY THOMPSON LIGHTNING 3.
FOR LIGHTNING PROTECTION DETAILS SEE ES530 SERIES DRAWINGS.2.
FOR ELECTRICAL LEGEND SEE DRAWING GG10.1.
NOTES:
AREA (TYP)
CIRCULAR MILS CROSS SECTIONAL
LBS/1000 FT AND HAVING A 98,600
WITH 14 AWG STRANDS WEIGHING 95
LIGHTNING PROTECTION CONDUCTOR
PROVIDE BRAIDED BARE ALUMINUM
WALLS (TYP FOR 3) (SEE NOTE 4)
CONDUIT EMBEDDED IN EXTERIOR
TO GROUND GRID; INSTALL IN 1"
PROTECTION DOWN CONDUCTOR
THRU-ROOF TERMINAL; LIGHTNING
AIR TERMINAL (TYP)
1/2" X 12" ALUMINUM SAFETY
BOND TO ROOF
MOUNTED
MECHANICAL
EQUIPMENT AS
REQUIRED
BOND TO EXISTING
LIGHTNING
PROTECTION
SYSTEM
NORTH
BOND TO EXISTING
LIGHTNING PROTECTION
SYSTEM
EF-108
EF-109
C H -1
.1
M A
X S
P A
C
IN
G
T Y
P
BOND (TYP)
EXOTHERMIC
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
CABLE TRAY DETAILS
SHEET 1
ES500 0
CONDUCTOR TO TRAY
BOND GROUNDING
GROUND CONNECTOR,
5/16" HOLE INSIDE OF TRAY
THE OUTSIDE OF TRAY; DRILL AND DEBURR
W/ NUT AND LOCK WASHER; INSTALL NUT ON
1/4"X3/4" SS ROUND HEAD, SLOTTED SCREW
CABLE TRAY
EACH SECTION OF
CONNECT TO
CABLE CLAMP,
60' INTERVALS.
STEEL AND GROUND GRID AT A MAXIMUM OF
60', IT SHALL BE CONNECTED TO STRUCTURAL
GRID ON BOTH ENDS. WHEN LONGER THAN
TRAY SHALL BE CONNECTED TO GROUND
#2 AWG BARE COPPER
GROUNDING CONDUCTOR
CABLE CLAMP
CABLE TRAY
CABLE TRAY
SPLICE PLATE
EXPANSION
CABLE TRAY
TRAY EXPANSION
IN CABLE TO ALLOW FOR
PROVIDE ADEQUATE SLACK
GROUND CABLE;
#2 AWG BARE COPPER
CONNECTOR
GROUND
TO STRUCTURAL STEEL
BE BONDED TOGETHER AND GROUNDED
STACKED TRAYS ARE USED THEY SHALL
AND AT BOTH ENDS. WHERE PARALLEL OR
GRID EVERY 60' ALONG THE TRAY ROUTE
STRUCTURAL STEEL AND THE GROUND
CABLE TRAY SHALL BE GROUNDED TO
ON THE OUTSIDE OF THE TRAY
THAT THE THREADED PORTION OF BOLT IS
PLATES. INSTALL GROUND CONNECTOR SUCH
EACH SIDE OF SPLICE PLATES OR EXPANSION
A 9/16" BOLT HOLE SHALL BE DRILLED ON
FITTINGS; CONDUIT ENDS MUST BE REAMED AND PLASTIC BUSHING PROVIDED.
CONDUITS MUST BE SECURELY FASTENED TO CABLE TRAY USING APPROVED
SUPPORT CONDUITS FROM CABLE TRAY WITH APPROVED FITTINGS.
CABLE TRAY CLAMP
CONDUIT CONNECTED VIA
CABLE TRAY KNOCKOUT
CONDUIT CONNECTED VIA
PROVIDE GROUNDING BONDS ON ALL CONDUITS PER NFPA-70.
1.
2.
3.
KEYNOTES:
SECTION
FLOOR FIRE STOP DETAIL
CONDUIT THRU CONCRETE WALL OR
PLAN
BONDING JUMPER CABLE TRAY
EXPANSION PLATE
SECTION
CABLE TRAY GROUNDING DETAIL
NOTES:
TO CABLE TRAY
CONDUIT CONNECTION
ADAPTER
ATTACHMENT
CONDUIT
CONDUIT BUSHING
CABLE TRAY
CONDUIT TO TRAY ADAPTER DETAIL
BE APPLIED ON EACH SIDE OF PACKING MATERIAL.
FLUSH WITH TOP SURFACE OF FLOOR. IN WALLS, FILL MATERIAL TO
THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS,
FILL, VOID, OR CAVITY MATERIAL - SEALANT - MINIMUM 1/2" 4.
FLOOR OR WALL SURFACES.
CAST OR GROUTED INTO FLOOR OR WALL ASSEMBLY, FLUSH WITH
ELECTRICAL METALLIC TUBING, STEEL CONDUIT OR CAST IRON PIPE
METALLIC SLEEVE - NOMINAL 6" DIAMETER (OR SMALLER) 1.
ELECTRICAL METALLIC TUBING OR STEEL CONDUIT.
CONDUIT - NOMINAL 4" (OR SMALLER) DIAMETER STEELA.
CONDUITS MAY BE USED:
ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC
RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL
REQUIRED WITHIN THE FIRESTOP SYSTEM. PIPE OR CONDUIT TO BE
THE FIRESTOP SYSTEM. A NOMINAL ANNULAR SPACE OF 3/4" IS
THROUGH PENETRANTS - ONE CONDUIT TO BE CENTERED WITHIN 2.
FOR INSTALLATION OF FILL MATERIAL.
TO BE CENTERED IN WALLS MID DEPTH AND RECESSED TO ALLOW
THE REQUIRED THICKNESS OF FILL MATERIAL. PACKING MATERIAL
FROM TOP SURFACE OF FLOOR AS REQUIRED TO ACCOMMODATE
AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED
MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO OPENING
PACKING MATERIAL - MINIMUM 3" THICKNESS OF MINIMUM 4 PCF 3.
WALL
WALL
6" OVERLAP OF SLEEVES INTO TRAY
(TYP BOTH ENDS)
4" RGS CONDUITS AS REQUIRED BY
CABLE TRAY SIZE. SLEEVES AT EACH
TRAY WITH FIRESTOP TO MATCH
RATING OF WALL INSERTED AFTER
CABLES ARE PLACED. SEAL
CONDUITS WITH A CONDUIT SEALING
COMPOUND IN SEAL-OFF FITTING
OUTSIDE THE BSL RATED SPACE.
CHICO-STYLE HARDENING SEALANT
SHALL NOT BE USED.
PROVIDE A #2 AWG BARE
COPPER GROUND JUMPER TO
BOND CABLE TRAYS THROUGH
WALLS IN SECURE AREA OR
UNSECURE AREA.
WALL
NOTE:
SEE ARCHITECTURAL PLANS FOR BSL RATED SPACES.
CABLE TRAY
CABLE TRAY
CABLE TRAY THRU WALL ABOVE CEILING
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
SHEET 2
ES501 0
COAT FINISH
FLAT BLACK POWDER
COAT FINISH
FLAT BLACK POWDER
RACK WIDTH
FOR 1'-7"
(WELDED TO PANEL)
CABLE RING
/2
3 1/2"
(NYLON)
WIRE SADDLES
CABLE GUIDES
RAISED FLOOR
FLOOR.
CABLE TRAY FROM FLOOR TO 8'-0" ABOVE
PROVIDE VERTICAL PAN COVER OVER
REQUIRED FOR RADIUS OF BENDS IN TRAY.
PROVIDE STAND OFFS FOR CABLE TRAY AS
REQUIRED (TYP)
BRACKET; ATTACH TO ROOF DECK AS
SUPPORT ALL CABLES FROM TRAY
1.
2.
SPLICE PLATE (TYP)
VERTICAL TO HORIZONTAL TRANSITION
TO HORIZONTAL CONDUIT AND
HUB (TYP)
PROOF
WEATHER
ENCLOSURE
EQUIPMENT
SEAL COMPOUND
PROVIDE DUCT
CABLE TRAY DROPOUT
WALL
BACKBOARD
3" ABOVE PLYWOOD
TELECOMM ROOM
LADDER RACK IN
DISCIPLINES TO AVOID CONFLICTS IN THE ROUTING OF THE CABLE TRAYS
TRAY AT THE POINT OF EXIT FROM THE COMMUNICATIONS ROOM. COORDINATE WITH ALL OTHER
PROVIDE CABLE TRAY TRANSITION FOR EACH NON-SECURE CABLE TRAY AND THE SIPRNET CABLE
DISTRIBUTION
TO BUILDING
TRAY WITH COVER
SOLID BOTTOM CABLE
SWEEP
SWEEP
CABLE LADDER
REQUIRED
FIRE STOPPING AS
1.
SELF-SEALING INTUMESCED INSERTS.
OR WIRING SHALL BE THROUGH MODULAR, RE-RNTERABLE FIRE STOPPING DEVICE(S) CONTAINING
PENETRATIONS OF FIRE-RATED PARTITIONS, WALLS OR FLOORS BY TELECOMMUNICATIONS PATHWAYS
ALL WALL PENETRATIONS MUST BE SEALED, FINISHED, AND FIRE STOPPED AS REQUIRED. 2.
NOTES:
CABLE TRAY TRANSITION
NOTES:
CABLE TRAY VERTICAL TRANSITION
TYPICAL LADDER RACK
TEE INTERSECTION
TYPICAL CABLE LADDER
TYPICAL CABLE LADDER
RACK ELEVATION RISER TYPICAL CABLE TRAY INSTALLATION DETAILS
TO VERTICAL CONDUIT TRANSITION
INSERT
TO CEILING
CABLE LADDER RACK DETAIL
CABLE MANAGEMENT
PANEL DETAIL
CABLE MANAGEMENT
PANEL DIMENSIONAL DETAIL
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
SHEET 3
ES502 0
6" 3/ 8"
CEILING HEIGHT VARIES
10'-6" MAXIMUM.
CABLE TRAY SUPPORTS SHALL BE SPACED
CABLE TRAY INSTALLATION
WINDOW OF ACCEPTABLE
1'-0"
LENGTH VARIES (TYP)
1/2" DIA THREADED ROD
FOR ALL THREADED RODS)
CABLE PROTECTION (TYP COVERING
3/4" DIAX1'-0" DIA X PVC CONDUIT FOR
1/2" DIA JAM NUT
CENTER DIVIDER
2'-0"X4" CABLE
TIE DOWN CLIPS
UNI-STRUT SUPPORT
1 5/8"X2'-6"
1/2" NUT
1'-0"
CLAMP (TYP)
CABLE
AS REQUIRED)
(SIZE & LENGTH
"J HOOK"
ROD (ATR)
ALL THREADED
HEX NUT
BEAM CLAMP
B760 SERIES
DOUBLE NUT
WASHER DOUBLE NUTBEAM CLAMP
CABLE TRAY
HEX NUT
CLAMPS
HOLD DOWN
METAL CHANNEL
MAX
HORIZONTAL ELBOWS HORIZONTAL CROSS HORIZONTAL TEE VERTICAL TEE
HORIZONTAL WYE OFFSET REDUCER STRAIGHT REDUCER VERTICAL ELBOWS
(TYP FOR ALL)
SUPPORT
SUPPORT
2'-0"
45°
2/3 RAD
M A X2'
-0
MAX (TYP)
2'-0"
MAX (TYP)
2'-0"
1/2 L
L
MAX (TYP)
2'-0"
MAX (TYP)
2'-0"
(TYP)
MAX
2'-0"
(TYP)
MAX
2'-0"
(TYP)
MAX
2'-0"
SLOTTED CHANNEL (TYP)
1 1/2"X1 1/2" GALVANIZED METAL
HARDWARE TO BE STAINLESS STEEL
CLAMPING NUT WITH SPRING; ALL
FLAT WASHER, LOCK WASHER AND
TRAY HOLD DOWN CLAMP WITH BOLT,
INDICATED ON DRAWINGS
CABLE TRAY, SIZE AS
LBS PER LINEAL FOOT LOAD
OF FLOOR ABOVE TO SUPPORT 230
EXPANSION ANCHORS TO UNDERSIDE
(WHERE APPLICABLE)
CEILING
DRAWINGS
INDICATED ON
HEIGHT AS
FLOOR DECK ABOVE
UNDERSIDE OF
ROD 3/8" DIA
THREADED HANGER
SLOTTED HOLES
METAL STRUT WITH
AS REQUIRED)
U-BOLT (SIZE & LENGTHEN
WASHER
METAL CHANNEL
ROOF PURLIN OR FLOOR BEAM
BEAM
EQUIPPED WITH PVC SLEEVES
FASTENED ON THREADED RODS. THREADED RODS TO BE
ROD. INSTALL PLASTIC ACORN NUT ON ALL NUTS
HARDWARE TO BE STAINLESS STEEL EXCEPT THREADED
SUPPORT 230 LBS PER LINEAL FOOT LOAD LOADING ALL
LOCK WASHER AND CLAMPING NUT WITH SPRING TO
THREADED ROD WITH DOUBLE LOCKNUTS, FLAT WASHER,
VERTICAL CABLING SECTION
TELECOMMUNICATION RACK
M
IN
OVERHEAD CABLE TRAY SUPPORT
(TYP)
2/3 RAD
(TYP)
22.50°
TYPICAL SUPPORT LOCATIONS FOR FITTINGS
NOTE:
CABLE TRAY SUPPORT DETAIL
1'-0"
1'-6"
COMMUNICATIONS CABLE LADDER SUSPENDED
FROM CONCRETE SLAB INSTALLATION DETAIL
INDOOR MOUNTING DETAIL
ROD (ATR)
ALL THREADED
FRAMING STRUT
CABLE TRAY
CLAMPS
HOLD DOWN
CABLE TRAY WIDTH
AS REQUIRED PER
SINGLE LEVEL TRAPEZE HANGER
LIGHT FIXTURE
CABLE TRAY
AND PIPING
MECHANICAL DUCTS
MEMBER
STRUCTURAL
V A
R
IE
S
CEILING
ABOVE CEILING SPACE ALLOCATIONS
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa 52761-3764
USDA NATIONAL CENTERS FOR ANIMAL HEALTH
COMMUNICATION DETAILS
SHEET 1
ES510 0
1'- 5/
/2
3"
7/8" DIA HOLES
/8
'-6 /1 6"
1'- 6"
1/2"
5/8"
TAPPED HOLES
1/2" DIA, 24 UNF
1. PROVIDE 6 AWG GROUND FROM RACK TO TGB.
1'- 6"
1'- 5/
/8
5/8"
RECEPTACLE (TYP)
DUPLEX
PANEL SHOWN
3#12 (IN 3/4" CND) TO
CABLE IN 1" CND
CATEGORY 6
RECESSED FLOOR BOX OR EQUAL)
DUPLEX RECEPTACLES (LEGRAND RFB4
FOR VOICE/DATA JACK AND 120 VAC
PROVIDE FLOOR BOX WITH BRACKETS
ADJACENT FLOOR
TO MATCH
PAINT OR CARPET
COMMUNICATION OUTLET
BACKBOX FOR
DUPLEX RECEPTACLE
CEILING, (1) NEMA 5-20R
(2) CAT-6A DATA ROUTED TO
BOX FOR PROJECTOR WITH
4" DEEP RECESSED FLOOR
TO PANELBOARD
(1) 3/4" CND WITH POWER
(2) CAT-6A DATA
1" CND,
GREATER
NEC, WHICHEVER IS
CHAPTER 9 TABLE 2 OF THE
OR AS SPECIFIED IN
SHALL NOT BE LESS THAN 6"
CONDUIT BEND RADIUS
WITH CAT-6A DATA CABLE TRAY
PANELBOARD AND (1) 3/4" CND
(1) 3/4" CND WITH POWER TO
RECEPTACLE
DATA, (1) NEMA 5-20R SIMPLEX
PROJECTOR WITH (2) CAT-6A
CEILING A/V BOX FOR
6"
CONNECTOR AND BUSHING
PROVIDE 1" BOX
BACK BOX DEPTH = 2"
4-11/16"X4-11/16"
CEI
LI
NG
SUPPORT
CABLE TRAY
INDEPENDENT OF CABLE TRAY
CONDUIT SUPPORT SHALL BE
DRY
W
ALL
CHAPTER 9 TABLE 2 OF THE NEC
BE LESS THAN SPECIFIED IN
CONDUIT BEND RADIUS SHALL NOT
PLASTIC BUSHING
1'-0"
1'-3"
NOTE:
TELECOMMUNICATION
RACK DETAIL
MECHANICAL TUBING
1" ELECTRICAL
CEI
LI
NG
M
ASO
NRY
W
ALL
BACK BOX DEPTH = 2"
4-11/16"X4-11/16"
CONNECTOR AND BUSHING
PROVIDE 1" BOX
PLASTIC BUSHING
SUPPORT
CABLE TRAY
MECHANICAL TUBING
1" ELECTRICAL
INDEPENDENT OF CABLE TRAY
CONDUIT SUPPORT SHALL BE
CHAPTER 9 TABLE 2 OF THE NEC
BE LESS THAN SPECIFIED IN
CONDUIT BEND RADIUS SHALL NOT
COMMUNICATIONS OUTLET
DROP DETAIL
COMMUNICATIONS OUTLET DROP
DETAIL (SURFACE MOUNTED) FLOOR BOX DETAIL
VOICE/DATA JACK
WHERE REQUIRED
ABOVE CEILING
TO CABLE TRAY
TELEPHONE (TYP)
BACK BOX FOR
PLASTER RING
WITH A SINGLE GANG
4 3/4"X4 3/4"X2"D
6"
FLOOR
CEILING
ROOM
COMMUNICATIONS
CABLE TRAY TO
SPACE ZONE
CLEAR
CONDUIT END
BUSHING ON
PROVIDE INSULATED
ABOVE CEILING VOICE/DATA DETAIL
WALL AND FLOOR BOXES
2" CND (2) CAT-6A DATA TO
WHICHEVER IS GREATER
IN CHAPTER 9 TABLE 2 OF THE NEC,
BE LESS THAN 10" OR AS SPECIFIED
CONDUIT BEND RADIUS SHALL NOT
MULTI-MEDIA OUTLET DETAIL
AND PULL BOXES WITH ARCHITECTURAL PLANS.
COORDINATE EXACT LOCATIONS OF PROJECTOR
NOTE:
1.
COMMUNICATIONS ROOM RACK ELEVATIONS
1. FOR USE IN BREAK ROOM 108.
NOTE:
1" MIN CONDUIT 1" MIN CONDUIT
MAY 31, 2019
NC VEEN
1 2
C A
D D D
-R
C
B
3 4 5
F
E
G
D
6 7 8 9
REV.
10 11
CHECKED
DESIGNED
APPROVED
APPROVED
DATE
DRAWN
SCALE:
NO.
A
DATENO. REVISIONS APVDCHKDDSGN
B
C
E
F
G
C STANLEY CONSULTANTS
www.stanleyconsultants.com
225 Iowa Avenue, Muscatine, Iowa…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .