This document package includes construction documents and specifications for repair work on Roof B106 at the Bay Pines VA Healthcare System in Florida. The related federal contract opportunity is a solicitation from the Department of Veterans Affairs for repair services to the roof. Key details of the solicitation include repairing the roof of an existing building using precast concrete panels and a single-ply roofing system. Bidders must also install roof insulation, flashing, drains, and other components as depicted in the construction drawings. The solicitation number is 36C24822R0116 and has an estimated award date in fiscal year 2022. The required completion date is not specified. The solicitation is designated for small businesses and will be awarded through full and open competition under the NAICS code 238160.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMPRESSIBLE TUBE
ROOFING MEMBRANE
MTL. STUD FRAMING,
TYP
EXTERIOR SHEATHING
BLOCKING,
TYP
BATT INSULATION
ROOF INSULATION 3" MIN
FIRESAFE INSULATION
ROOFING MANUFACTURE BASE
ATTACHMENT
FLOOR LEVEL
REGLET AND COUNTER
FLASHING
ROOFING MEMBRANE
EXISTING WALL
RIGID INSULATION
STRUCTURAL ANGLE, REFER TO
STRUCTURAL DWGS.
CIP STAIR TOWER WALL
1'-
6" M
IN
2"
TYP JOINTTYP REVEAL
DOUBLE
SEALANT JT
DP
CONCRETE
PRECAST PANEL
2" 1/4
6"
1"
1/4
1"
6"
DP
TYP REVEAL
DOUBLE
SEALANT JT.
DP
TYP JOINT
CONC PRECAST
PANEL
3/4
1"
1/8"
1"
3/4
1/8"
3/4"
FILTER FABRIC
DRAIN BODY
UNDER DECK CLAMP
ELASTOMERIC
MEMBRANE W.P.
ELASTOMERIC
FLASHING, EXTEND
INTO DRAIN BODY
INSULATION
DRAIN PIPE
STRAINER
C DRAINL
FLOOR LEVEL
OVERFLOW COLLAR, TYPICAL
FOR OVERFLOW DRAINS
NOTE: HORIZONTAL PRECAST DRIP
AT ALL EXPOSED HORIZONTAL
PANEL SOFFIT EDGES.
3/8"
3/8
1"
FLOOR LEVEL
COMPRESSIBLE TUBE
ROOFING MEMBRANE
MTL. STUD FRAMING
EXTERIOR SHEATHING
BLOCKING, TYP
BATT INSULATION
ROOF INSULATION
3" MIN
FIRESAFE INSULATION
ROOFING MANUFACTURE
BASE ATTACHMENT1'-
6" M
IN
2"
BENT PLATE - SEE STRUCTURE
6"
FLUID APPLIED AIR
BARRIER, TYP.
FIRESAFING & SMOKE
SEALANT UL-CWS 2002
DP
DP
TAPERED ROOF
INSULATION, 3" MIN.
CONC PRECAST PANEL
FLOOR LEVEL
DP
EDGE OF SLAB
PT WOOD BLOCKING
PRE-FINISHED METAL
COPING
EXTERIOR SHEATHING
4" SEMI-RIGID INSULATION
ATTACH TO BLOCKING. NO
ATTACHMENT TO PRECAST
CONCRETE PANEL ON
EXTERIOR SIDE. (TYP.)
6"
1/2
SINGLE PLY ROOFING
SYSTEM, TYPICAL
BENT PLATE - SEE STRUCTURE
CONCRETE PRECAST
CORNER PANEL
DOUBLE SEALANT AND
BACKEROD, TYPICAL
3/4
3'- 1/2
" M
AX
TY
P1"
3/4"
3'-1/2" MAX
SET LEAD FLANGE IN
MASTIC-PRIME FLANGE
BEFORE FLASHING
2-PLY FLASHING OR
ROOF MANUF.BOOT
ROOF INSULATION
ROLLED LEAD
FLASHING 1" MIN. INTO
PIPE LEAD FLASHING
CONCRETE OVER
METAL DECK
FIRE-STOP INSUL.
EDGE OF SLAB
FLOOR LEVEL
TYP
4" MIN
3" M
IN
2"
4" MTL. COUNTER
FLASHING
ROOF INSULATION
MECH. EQUIPMENT
SEE MECH. DWG.
MTL. COUNTER
FLASHING
INSULATION CURB
EDGE OF SLAB
FLOOR LEVEL
" M
IN
3" M
IN
BENT PLATE - SEE STRUCTURE
TOS 2
42' - 2"
ROOF
42' - 6"
6"
FLUID APPLIED AIR
BARRIER, TYP.
FIRESAFING & SMOKE
SEALANT UL-CWS 2002
DP
DP
TAPERED ROOF
INSULATION, 3" MIN.
CIP CONCRETE
DP
EDGE OF SLAB
4" SEMI-RIGID INSULATION
SINGLE PLY ROOFING
SYSTEM, TYPICAL
TAPERED ROOF
INSULATION, 3" MIN.
SINGLE PLY ROOFING
SYSTEM, TYPICAL
BENT PLATE - SEE STRUCTURE
HELLMUTH, OBATA & KASSABAUM, INC.
ARCHITECTURE, ENGINEERING, PLANNING,
INTERIORS, GRAPHICS, CONSULTING
Drawing Number:
Drawing Title: Project Number
DrawnChecked:
CONSULTANTS Project Title
Building Number
All reproduction & intellectual property rights reserved © 2008
Revisions
Client Location
Contract No:
One Tampa City Center, Suite 1800, Tampa, FL, 33602 Voice:
Fax:
Internet:
| 813 | 229 - 0300 | 813 | 223 - 7116 http://www.hok.com
Date
ARCHITECT/ ENGINEERS:
FL. Reg. AAC001139
Approved: Division Chief
Date
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot th re e ei gh th s in ch o ne fo ot on e ha lf in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
D e p ar tm en t of V e t er an s
A ff ai rs
CONSTRUCTION DOCUMENTS CD 3
FULLY SPRINKLERED
BAY PINES HEALT
HCARE SYSTE
M
Approved: Service Director
05.29010.09 / 05.29010.13
Bay Pines FL 33744
ROOF AND EXTERIOR DETAILS
AS-851
KC -07/07/2009
516-326 / 516-334VA Bay Pines Healthcare System - Eye Treatment Center &
Ambulatory Surgery Center
3" = 1'-0"H ROOF EXPANSION JOINT
3" = 1'-0"A CONC PRECAST HORIZ JT/REVEAL DETAIL
3" = 1'-0"B CONC PRECAST VERT JT/REVEAL DETAIL
3" = 1'-0"C ROOF DRAIN DETAIL
3" = 1'-0"G PRECAST DRIP DETAIL, TYPICAL
3" = 1'-0"E ROOF EXPANSION JOINT
3" = 1'-0"D CONC PRECAST PARAPET SECTION
3" = 1'-0"F PRECAST CORNER DETAIL (TYP.)
3" = 1'-0"L VENT STACK FLASHING
3" = 1'-0"M MECHANICAL EQUIPMENT CURB
1 ADDENDUM #3 2009.08.28
3" = 1'-0"J ROOF DETAIL