About this file

This document package includes construction documents and specifications for repair work on Roof B106 at the Bay Pines VA Healthcare System in Florida. The related federal contract opportunity is a solicitation from the Department of Veterans Affairs for repair services to the roof. Key details of the solicitation include repairing the roof of an existing building using precast concrete panels and a single-ply roofing system. Bidders must also install roof insulation, flashing, drains, and other components as depicted in the construction drawings. The solicitation number is 36C24822R0116 and has an estimated award date in fiscal year 2022. The required completion date is not specified. The solicitation is designated for small businesses and will be awarded through full and open competition under the NAICS code 238160.

View the file

Other files

File Type Posted
S06_36C24822R0116 0003.pdf PDF
P09_ IGE B106 Roof- Rev 2.doc DOC document
as-203.pdf PDF
Q and A Question_response 6_09_2022 (1).xlsx XLSX spreadsheet
as-702.pdf PDF
077100 roof specialties.pdf PDF
as-701.pdf PDF
264100 lightning protection.pdf PDF
077200 roof accessories.pdf PDF
ep-113.pdf PDF
072213 roof and deck insulation.pdf PDF
075423 tpo.pdf PDF
36C24822R0116 0002.pdf PDF
076000 flashing and sheet metal.pdf PDF
as-723.pdf PDF
Attachment 10 Contract Progress Schedule.pdf PDF
Amend_ 36C24822R0116 0001.pdf PDF
AS-502.pdf PDF
36C24822R0116.docx DOCX document
Attachment 3 - LOS Certification Solicitation Version.doc DOC document
AS-100.pdf PDF
attachment 9 - q_a rfis.xlsx XLSX spreadsheet
AS-502 02.pdf PDF
AS-501.pdf PDF
AS-703.pdf PDF
Wage Determination 2022.pdf PDF
Attachment 4 - Price Matrix.xlsx XLSX spreadsheet
Attachment 8 (Exhibit B) Past and Present Performance Questionnaire.docx DOCX document
AS-203-FLO.pdf PDF
Attachment 6 -(Exhibit C) EMR.docx DOCX document
Site Location.pptx PPTX presentation
Attachment 7- (Exhibit A) Performance Relevancy Survey v2.docx DOCX document
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMPRESSIBLE TUBE

ROOFING MEMBRANE

MTL. STUD FRAMING,

TYP

EXTERIOR SHEATHING

BLOCKING,

TYP

BATT INSULATION

ROOF INSULATION 3" MIN

FIRESAFE INSULATION

ROOFING MANUFACTURE BASE

ATTACHMENT

FLOOR LEVEL

REGLET AND COUNTER

FLASHING

ROOFING MEMBRANE

EXISTING WALL

RIGID INSULATION

STRUCTURAL ANGLE, REFER TO

STRUCTURAL DWGS.

CIP STAIR TOWER WALL

1'-

6" M

IN

2"

TYP JOINTTYP REVEAL

DOUBLE

SEALANT JT

DP

CONCRETE

PRECAST PANEL

2" 1/4

6"

1"

1/4

1"

6"

DP

TYP REVEAL

DOUBLE

SEALANT JT.

DP

TYP JOINT

CONC PRECAST

PANEL

3/4

1"

1/8"

1"

3/4

1/8"

3/4"

FILTER FABRIC

DRAIN BODY

UNDER DECK CLAMP

ELASTOMERIC

MEMBRANE W.P.

ELASTOMERIC

FLASHING, EXTEND

INTO DRAIN BODY

INSULATION

DRAIN PIPE

STRAINER

C DRAINL

FLOOR LEVEL

OVERFLOW COLLAR, TYPICAL

FOR OVERFLOW DRAINS

NOTE: HORIZONTAL PRECAST DRIP

AT ALL EXPOSED HORIZONTAL

PANEL SOFFIT EDGES.

3/8"

3/8

1"

FLOOR LEVEL

COMPRESSIBLE TUBE

ROOFING MEMBRANE

MTL. STUD FRAMING

EXTERIOR SHEATHING

BLOCKING, TYP

BATT INSULATION

ROOF INSULATION

3" MIN

FIRESAFE INSULATION

ROOFING MANUFACTURE

BASE ATTACHMENT1'-

6" M

IN

2"

BENT PLATE - SEE STRUCTURE

6"

FLUID APPLIED AIR

BARRIER, TYP.

FIRESAFING & SMOKE

SEALANT UL-CWS 2002

DP

DP

TAPERED ROOF

INSULATION, 3" MIN.

CONC PRECAST PANEL

FLOOR LEVEL

DP

EDGE OF SLAB

PT WOOD BLOCKING

PRE-FINISHED METAL

COPING

EXTERIOR SHEATHING

4" SEMI-RIGID INSULATION

ATTACH TO BLOCKING. NO

ATTACHMENT TO PRECAST

CONCRETE PANEL ON

EXTERIOR SIDE. (TYP.)

6"

1/2

SINGLE PLY ROOFING

SYSTEM, TYPICAL

BENT PLATE - SEE STRUCTURE

CONCRETE PRECAST

CORNER PANEL

DOUBLE SEALANT AND

BACKEROD, TYPICAL

3/4

3'- 1/2

" M

AX

TY

P1"

3/4"

3'-1/2" MAX

SET LEAD FLANGE IN

MASTIC-PRIME FLANGE

BEFORE FLASHING

2-PLY FLASHING OR

ROOF MANUF.BOOT

ROOF INSULATION

ROLLED LEAD

FLASHING 1" MIN. INTO

PIPE LEAD FLASHING

CONCRETE OVER

METAL DECK

FIRE-STOP INSUL.

EDGE OF SLAB

FLOOR LEVEL

TYP

4" MIN

3" M

IN

2"

4" MTL. COUNTER

FLASHING

ROOF INSULATION

MECH. EQUIPMENT

SEE MECH. DWG.

MTL. COUNTER

FLASHING

INSULATION CURB

EDGE OF SLAB

FLOOR LEVEL

" M

IN

3" M

IN

BENT PLATE - SEE STRUCTURE

TOS 2

42' - 2"

ROOF

42' - 6"

6"

FLUID APPLIED AIR

BARRIER, TYP.

FIRESAFING & SMOKE

SEALANT UL-CWS 2002

DP

DP

TAPERED ROOF

INSULATION, 3" MIN.

CIP CONCRETE

DP

EDGE OF SLAB

4" SEMI-RIGID INSULATION

SINGLE PLY ROOFING

SYSTEM, TYPICAL

TAPERED ROOF

INSULATION, 3" MIN.

SINGLE PLY ROOFING

SYSTEM, TYPICAL

BENT PLATE - SEE STRUCTURE

HELLMUTH, OBATA & KASSABAUM, INC.

ARCHITECTURE, ENGINEERING, PLANNING,

INTERIORS, GRAPHICS, CONSULTING

Drawing Number:

Drawing Title: Project Number

DrawnChecked:

CONSULTANTS Project Title

Building Number

All reproduction & intellectual property rights reserved © 2008

Revisions

Client Location

Contract No:

One Tampa City Center, Suite 1800, Tampa, FL, 33602 Voice:

Fax:

Internet:

| 813 | 229 - 0300 | 813 | 223 - 7116 http://www.hok.com

Date

ARCHITECT/ ENGINEERS:

FL. Reg. AAC001139

Approved: Division Chief

Date

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9 on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot th re e ei gh th s in ch o ne fo ot on e ha lf in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot th re e in ch es o ne fo ot

D e p ar tm en t of V e t er an s

A ff ai rs

CONSTRUCTION DOCUMENTS CD 3

FULLY SPRINKLERED

BAY PINES HEALT

HCARE SYSTE

M

Approved: Service Director

05.29010.09 / 05.29010.13

Bay Pines FL 33744

ROOF AND EXTERIOR DETAILS

AS-851

KC -07/07/2009

516-326 / 516-334VA Bay Pines Healthcare System - Eye Treatment Center &

Ambulatory Surgery Center

3" = 1'-0"H ROOF EXPANSION JOINT

3" = 1'-0"A CONC PRECAST HORIZ JT/REVEAL DETAIL

3" = 1'-0"B CONC PRECAST VERT JT/REVEAL DETAIL

3" = 1'-0"C ROOF DRAIN DETAIL

3" = 1'-0"G PRECAST DRIP DETAIL, TYPICAL

3" = 1'-0"E ROOF EXPANSION JOINT

3" = 1'-0"D CONC PRECAST PARAPET SECTION

3" = 1'-0"F PRECAST CORNER DETAIL (TYP.)

3" = 1'-0"L VENT STACK FLASHING

3" = 1'-0"M MECHANICAL EQUIPMENT CURB

1 ADDENDUM #3 2009.08.28

3" = 1'-0"J ROOF DETAIL

File details come from the government source that posted it. Updated .