as-203.pdf
PDF 136 KB Posted
- Solicitation number
- 36C24822R0116
About this file
This document package includes a floor plan drawing and related federal contract opportunity solicitation. The floor plan drawing depicts mechanical, electrical, and plumbing details for the penthouse and roof of Building 106 at the Bay Pines VA Healthcare System. The drawing includes notes specifying materials, dimensions, and work to be performed.
The related federal contract opportunity is a combined synopsis/solicitation seeking offers to repair the roof of Building B106 under project number 516-22-118. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration VISN 8. Offerors are invited to submit pricing for roof repair services by the response date listed on the solicitation. The award is to be made to a contractor who can best meet the requirements at a fair and reasonable price. The opportunity is not set aside for small businesses or other socioeconomic categories.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FD
FD
A B C D E
12.8
MECH.
3G-100AS-501
E
AS-502A
AS-501
D
AS-502 C
B
AS-701
A
AS-701
STAIR 12
3G-122S
3/
4"
56' - 4"
E
AS-422
C
AS-701
B
AS-702
23' - 6"
AS-501
G
AS-502D
AS-501
F
AS-502 E
AS-501
A
AS-501
H
AS-501B
AS-502 B
B.5 D.6
11.3
12.3
8"
1 1
/2"
6' - 0"
E 2
H8.21
SS
C.3
6'
- 0
8' - 5"
A
AS-703
A
AS-723
E 2
H8.26
SS
RD
OD
RD
OD
RD
OD
RD
OD
7' - 6" 10' - 0 1/2"
3' - 0 1/2"
3'
- 0
E
AS-851
SIM
D
AS-851
Sim
D
AS-851
Sim
D
AS-851
Sim
D
AS-851
Sim
C
AS-851
TYP
SCREEN WALL
CHILLER, CURB
6' - 9" 25' - 0" 11' - 0" 14' - 0" 8' - 5" 16' - 7" 14' - 10" 10' - 2" 2' - 1 1/2"
100' - 0"
2'
- 0
2'
- 1
1/ 2"
1 1 /2"
1/
2"
8"
8" 8'
- 8
0"
0"
2'
- 1
1/ 2"
ROOF PAD, TYP
L2
5' - 3"
D
AS-851
Sim
D
AS-851
Sim
4'
- 9
MECHANICAL
HOUSEKEEPING PAD
8' - 4 1/2"
8'
- 4
1/ 2"
EXHAUST FAN, TYP
ACCESS LADDER
EXHAUST FAN, TYP
2' - 2"
RD
OD
5' - 11 1/2" E.J.
D
AS-851
Sim
H
AS-851
Sim
J
AS-851
C D
A
AS-701
AS-502D
AS-501
F
AS-502 E
B.5 D.6
11.3
12.3
C.3 A
AS-703
RDOD
TYP
F
AS-851
1' - 9" 14' - 0" 8' - 5" 16' - 7" 14' - 10"
1' - 9" 1'
- 7 1/
2"
8"
1/
2" 1'
- 9
D
AS-851
Sim
53' - 10"
6 1 /2"
A B
D
AS-851
Sim
SCUPPER BOX AND
DOWNSPOUT
PROVIDE SPLASH
BLOCK ON ROOF
BELOW
GENERAL PLAN NOTES:
1. ALL GYP BD PARTITIONS SHALL BE TAPED, SPACKLED, AND SANDED WITH NO VISIBLE JOINTS. PATCH AND REPAIR SURFACES TO MATCH ADJACENT OR ADJOINING SURFACES WHERE REQUIRED. ALL SURFACES
SHALL BE ALIGNED.
2. WHERE FURRED PARTITIONS EXCEED MAXIMUM HEIGHT. BRACE TO ADJACENT STRUCTURE, PER DETAIL.
3. FIRE SAFE PENETRATIONS AT RATED PARTITIONS PER APPLICABLE UL ASSEMBLY. REFER TO PARTITION
DETAILS IN THE DOCUMENT SET.
4. ALL INTERIOR PARTITIONS, PENETRATIONS, OTHER OPENINGS IN THE BUILDING SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED.
5. PROVIDE METAL BLOCKING AS REQUIRED AT LOCATIONS INCLUDING BUT NOT LIMITED TO: GRAB BARS, SHELVING, OVERHEAD CABINETS, SIGNAGE, TOILET ROOM ACCESSORIES, ETC.
6. PROVIDE FIRE MTL. BLOCKING AS REQUIRED AT ALL CORRIDOR HANDRAIL LOCATIONS. SEE FINISH PLAN
FOR HANDRAIL LOCATIONS.
7. ALL WOOD TO BE FIRE RETARDANT TREATED IN ACCORDANCE WITH LOCAL CODES.
8. PROVIDE CORNER GUARDS AT ALL OUTSIDE CORNERS. SEE INTERIOR FINISH PLAN FOR LOCATIONS.
9. ALL GYP BD PARTITIONS RECEIVING RUBBER BASE TO BE FINISHED SMOOTH TO THE SLAB.
10. PATCH AND REPAIR EXISTING SLAB WHERE REQUIRED.
11. ALL PARTITIONS ARE DIMENSIONED FROM FACE OF FINISH TO FACE OF FINISH UNLESS OTHERWISE NOTED.
ALL DIMENSIONS MARKED "CLEAR" OR "HOLD" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF ALL
WALL FINISHES.
12. DIMENSIONS NOTED "CLEAR" OR "HOLD" MUST BE ACCURATELY MAINTAINED AND SHALL NOT VARY MORE
THAN +/- 1/8" WITHOUT WRITTEN CONSENT FROM THE ARCHITECT
13. PROVIDE BLOCKING/SUPPORT AS NECESSARY FOR MILLWORK.
14. CONTRACTOR TO COORDINATE AND PROVIDE BLOCKING FOR ALL OWNER SUPPLIED EQUIPMENT AND FURNITURE. CONTRACTOR SHALL INSTALL ALL REQUIRED BLOCK PRIOR TO INSTALLATION OF GWB IN ALL
LOCATIONS.
15. PROVIDE POWER FOR AUTOMATIC DOOR OPENERS AND ASSOCIATED HARDWARE. COORDINATED WITH
ELECTRICAL CONTRACTOR AND HARDWARE SUPPLIER.
16. NEW PNEUMATIC TUBE RECEIVERS FOR NEW BUILDING ADDITION WILL TIE INTO EXISTING BUILDING 100 PNEUMATIC TUBE SYSTEM ZONE 2. NEW SYSTEM FOR BUILDING ADDITION WILL BE COORDINATED WITH
THE MEDICAL CENTER TO MINIMIZE DOWN TIME OF THE EXISTING PNEUMATIC TUBE SYSTEM.
EXISTING 2-PORT TRANSFER STATION (#27) WILL BE REMOVED AND REPLACED WITH A NEW 4-PORT TRANSFER STATION. THE EXISTING TRANSFER STATION (#27) IS LOCATED IN BUILDING 100 INTERSTITIAL SPACE, AREA 1B, APPROXIMATELY 25FT WEST OF COLUMN D.4/26. THE NEW 4-PORT SYSTEM SHALL SERVE EXISTING PNEUMATIC TUBE STATIONS AND NEW PNEUMATIC TUBE STATION LOCATED IN THE EYE TREATMENT CENTER (RECEPTION ROOM 161). CONTRACTOR SHALL PROVIDE A FULLY FUNCTIONING SYSTEM IN COMPLIANCE WITH THE
CONTRACT REQUIREMENTS.
PNEUMATIC TUBE STATIONS SHALL BE MODEL CTS TL 2007 (OR THE LATEST VERSION OF THIS PTS) WITH I.Q.
CONTROLS OR EQUAL, PROVIDE A 3-PORT TRANSFER STATION IN THE ETC INTERSTITIAL TO SERVE THE PTS IN ROOM 161 AND THE TWO (2) PTS IN ASC (ONE IN THE CONTROL ROOM AND ONE IN THE MEDICAL
EQUIPMENT ROOM ADJACENT TO THE NURSE STATION IN THE PACU AREA).
THE TWO (2) 6-INCH CONDUITS WILL HAVE TO BE ROUTED FROM THE FIRST FLOOR INTERSTITIAL TO THE
SECOND FLOOR INTERSTITIAL, AND THEN DOWN TO THE PTS IN ASC.
17. ALL PRECAST PANELS ARE TO BE SPRAYED WITH A CONTINUOUS VAPOR BARRIER (INTERIOR BUILDING SIDE), ALL SEAMS, BOTH INTERNAL AND EXTERNAL SHALL BE CAULKED.
HELLMUTH, OBATA & KASSABAUM, INC.
ARCHITECTURE, ENGINEERING, PLANNING,
INTERIORS, GRAPHICS, CONSULTING
Drawing Number:
Drawing Title: Project Number
DrawnChecked:
CONSULTANTS Project Title
Building Number
All reproduction & intellectual property rights reserved © 2008
Revisions
Client Location
Contract No:
One Tampa City Center, Suite 1800, Tampa, FL, 33602 Voice:
Fax:
Internet:
| 813 | 229 - 0300 | 813 | 223 - 7116 http://www.hok.com
Date
ARCHITECT/ ENGINEERS:
FL. Reg. AAC001139
Approved: Division Chief
Date
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot th re e ei gh th s in ch o ne fo ot on e ha lf in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot th re e in ch es o ne fo ot
D e p ar tm en t of V e t er an s
A ff ai rs
CONSTRUCTION DOCUMENTS CD 3
FULLY SPRINKLERED
BAY PINES HEALT
HCARE SYSTE
M
Approved: Service Director
05.29010.09 / 05.29010.13
Bay Pines FL 33744
FLOOR PLAN - PENTHOUSE/ROOF
AS-203
KC -09/08/2009
516-326 / 516-334VA Bay Pines Healthcare System - Eye Treatment Center &
Ambulatory Surgery Center
1/8" = 1'-0"A PENTHOUSE PLAN / ROOF PLAN
EXISITNG BUILDING 100
1/8" = 1'-0"B PENTHOUSE ROOF PLAN
1/8" = 1'-0"C PENTHOUSE STAIR ROOF PLAN
EXTERIOR
ROOF
LADDER
ROOF
MOUNTED
FAN
ROOF
MOUNTED
FAN
1 ADDENDUM #3 2009.08.28
2 ADDENDUM #4 2009.09.08
File details come from the government source that posted it. Updated .