These architectural and engineering documents detail renovation and network infrastructure specifications for Building 600 at Joint Base Elmendorf-Richardson (JBER), Alaska, specifically for the Alaska Resident Office (ARO) of the 311th Military Intelligence Battalion. The documents outline critical security requirements including:

Network infrastructure specifications include 18 NIPR drops (144 total connectors) and 11 SIPR drops (88 total connectors), with precise cabling requirements such as 12 strands of single-mode/single-strand fiber optic cable between Room 206 and Room B53. Security modifications include converting the entire office space to an Open Storage Collateral Secret area, removing two excess doorways in Room B53, installing an STC-45/50 entrance door, and conducting a comprehensive window verification survey. Additional basement renovation requirements include installing new IDS (Intrusion Detection System) for Military Intelligence, new ceiling grids, gyp board, paint, vinyl baseboards, restroom fixtures, and carpet in rooms B49 through B58, with specific conduit and cabling specifications for secure communication infrastructure.

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Windo w

Windo w

Windo w

Windo w

Windo w

Windo w

2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR

2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR

2xSIPR

2xSIPR 2xSIPR 2xSIPR 2xSIPR 2xSIPR

2xSIPR2xSIPR2xSIPR2xSIPR

B58B56B54B52B50

B57B55B53B51B49Bathrooms

SIPR

Rack

NIPR

Rack

2xSIPR

Windo w

Alaska Resident Office (ARO) Bldg 600, 311th Military Intelligence Battalion

Joint Base Elmendorf-Richardson (JBER), Alaska

Device Drop Locations NIPR Drop x 18 (2 drops per location)

SIPR Drop x 11 (2 drops per location)

Total Connectors Needed NIPR Drop x 18 (2 drops per location) x4 = 144 Connectors

SIPR Drop x 11 (2 drops per location) x4 = 88 Connectors

Entire office space (surrounded with dashed line) will be Open Storage

Collateral Secret once all requirements met.

Require verification/identification of all windows within open storage spaces along with room/door dimensions.

The ones shown are known windows.

There might be more, so need a thorough survey completed.

Two excess doorways (as identified in drawing in blue) in Room B53 need to removed and sealed floor-to-ceiling.

Entrance to ARO open storage Collateral Secret space (as identified in drawing) requires STC-45/50 door.

10' 14' 8' 8' 8" 8' 10" 13' 10"

12' 12' 16' 8" 8' 10" 13' 10"

70'4"

15' 11"

16' 6"

4' 6"36' 11"

Doorway to be sealed

Doorway to be sealed

2nd FL Room 206

TELCOMM

Room

12 strands SM / ST from 206 to B53 (approx. 500' feet with service loops)

Outside 311th MI controlled spaces

1265081548C Rectangle

1265081548C Rectangle

1265081548C Text Box B.600 Basement

1265081548C Callout New IDS Install for MI

1265081548C Callout COM Closet

1265081548C Polygonal Line

1265081548C Callout Conduit from Secure Area to Secure COM room, 3/4" Rigid. CAT6 Shielded.

14'-4

" 12'-2"

18'-4

9'-6" 13'-5"

7'-11"62'-0"

13'-11" 9'-5"

8'-1

8'-9" 14'-4"

11'-9"

4'-1"

B50 B52 B54 B56 B58

B57B55B53B51B49BATHROOMS

S T

O R

A G

E

A

B

C

D

E

F

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

N o

D A

T E

D E

S C

R I P

T I O

N B

Y

P R

O J E

C T

M

A N

A G

E R

D E

S I G

N E

D

B

Y

D

H J Z

H

X

X X

X X

X

XX

SHEET OF

SHEET REFERENCE

R E

V I S

I O

N S

D R

A W

N

B

Y

A N

S I

P L O

T

S

C A

L E

I N

V O

I C

E

N

U M

B E

R

R E

P A

I R

E N

O V

A T

E

B

A S

E M

E N

T

B

L D

G

J B

E R

F

O R

T

R

I C

H A

R D

S O

N

A

L A

S K

A

D R

A W

I N

G

S

C A

L E

D A

T E

A

F

P

R O

J E

T

N

U M

B E

R

F

O N

T R

A C

T

N

U M

B E

R

A E

C

F

I L E

M

E

R A

N D

Y

T

Y L E

R

C H

I E

F r d

C

E S

C

E P

M R

S

A

I

R

E

X X

D

E C

V

C

A B

L E

V

R

N W

E L L

V

C

A B

L E

P

A

X U

P

S

T

E D

X

A-101

A R

C H

I T

E C

T U

R A

L

C O

N S

T R

U C

T I O

N

P

L A

N

A D d w g

NOT FOR CONSTRUCTION

SITE LOCATION

INFILL WALLS WHERE DOORS HAVE BEEN REMOVED.

BLOCK WALL INFILL AFTER REMOVAL OF ALL WINDOWS.

INSTALL NEW DOORS AND HARDWARE, INCLUDING CLOSURES PER

DRAWING AND SPECIFICATIONS.

INSTALL NEW 2' X 2" CEILING GRID WITH SUPER DUPER SILENCING.

INSTALL NEW GYP BOARD AND PAINT ON ALL WALLS SHOWN

INSTALL VINYL BASEBOARD THROUGHOUT.

INSTALL NEW FIXTURES: TOILETS, URINALS, LAVATORIES, MOP SINK,

RESTROOM PARTITIONS.

INSTALL NEW CARPET IN ROOMS B49 THROUGH B58

CONSTRUCTION NOTES

SCALE: 1/4" = 1'

NEW FLOOR PLAN

03 04

1213 11

09 08

1 1

2 2 2 2

22 22

3 3 3

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

OPEN TO BELOW

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

1265081548C Text Box

KEY

- Entrance

- Emergency Exit Only

- Arm/Disarm w/Duress

- Motion, Curtain 24x7

- Motion, 360

- HSS (BMS) Doors with HSS and Curtain will be combined alarms.

- Existing Alarm Rack

- Large Pull Box, Secured

- Alarm Panel

1265081548C Oval

1265081548C Oval

1265081548C Rectangle

1265081548C Polygon

1265081548C Oval

1265081548C Rectangle

1265081548C Rectangle

1265081548C Oval

1265081548C Rectangle

1265081548C Rectangle

1265081548C Oval

1265081548C Oval

1265081548C Oval

1265081548C Oval

1265081548C Oval

1265081548C Oval

1265081548C Oval

1265081548C Oval

1265081548C Oval

1265081548C Oval

1265081548C Oval

1265081548C Polygonal Line

1265081548C Polygonal Line

1265081548C Polygonal Line

1265081548C Rectangle

1265081548C Rectangle

1265081548C Rectangle

1265081548C Rectangle

1265081548C Polygonal Line

1265081548C Polygonal Line

1265081548C Callout Conduit to COM Room

ARO B600 ISP Network Cable Installation Diagram
ARO B600 Open Storage Enclosures
Sheets and Views
NEW

File details come from the government source that posted it. Updated .