These architectural and engineering documents detail renovation and network infrastructure specifications for Building 600 at Joint Base Elmendorf-Richardson (JBER), Alaska, specifically for the Alaska Resident Office (ARO) of the 311th Military Intelligence Battalion. The documents outline critical security requirements including:
Network infrastructure specifications include 18 NIPR drops (144 total connectors) and 11 SIPR drops (88 total connectors), with precise cabling requirements such as 12 strands of single-mode/single-strand fiber optic cable between Room 206 and Room B53. Security modifications include converting the entire office space to an Open Storage Collateral Secret area, removing two excess doorways in Room B53, installing an STC-45/50 entrance door, and conducting a comprehensive window verification survey. Additional basement renovation requirements include installing new IDS (Intrusion Detection System) for Military Intelligence, new ceiling grids, gyp board, paint, vinyl baseboards, restroom fixtures, and carpet in rooms B49 through B58, with specific conduit and cabling specifications for secure communication infrastructure.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFI Answers for W912D025R0010 311th-02.docx | DOCX document | |
| Solicitation W912D025R00100003 Amended MOD copy.pdf | ||
| Solicitation W912D025R00100003 Amended Conformed copy.pdf | ||
| RFI Answers for W912D025R0010 .docx | DOCX document | |
| Solicitation W912D025R00100002 Amendment (MOD Copy).pdf | ||
| Solicitation W912D025R00100002 Amended Conformed copy.pdf | ||
| Solicitation W912D025R0010 Amended Conformed copy.pdf | ||
| Solicitation W912D025R00100001 Amendment (MOD Copy).pdf | ||
| Solicitation W912D025R0010.pdf | ||
| Wage Determination REV 23 June 02 2025..pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Windo w
Windo w
Windo w
Windo w
Windo w
Windo w
2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR
2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR 2xNIPR
2xSIPR
2xSIPR 2xSIPR 2xSIPR 2xSIPR 2xSIPR
2xSIPR2xSIPR2xSIPR2xSIPR
B58B56B54B52B50
B57B55B53B51B49Bathrooms
SIPR
Rack
NIPR
Rack
2xSIPR
Windo w
Alaska Resident Office (ARO) Bldg 600, 311th Military Intelligence Battalion
Joint Base Elmendorf-Richardson (JBER), Alaska
Device Drop Locations NIPR Drop x 18 (2 drops per location)
SIPR Drop x 11 (2 drops per location)
Total Connectors Needed NIPR Drop x 18 (2 drops per location) x4 = 144 Connectors
SIPR Drop x 11 (2 drops per location) x4 = 88 Connectors
Entire office space (surrounded with dashed line) will be Open Storage
Collateral Secret once all requirements met.
Require verification/identification of all windows within open storage spaces along with room/door dimensions.
The ones shown are known windows.
There might be more, so need a thorough survey completed.
Two excess doorways (as identified in drawing in blue) in Room B53 need to removed and sealed floor-to-ceiling.
Entrance to ARO open storage Collateral Secret space (as identified in drawing) requires STC-45/50 door.
10' 14' 8' 8' 8" 8' 10" 13' 10"
12' 12' 16' 8" 8' 10" 13' 10"
70'4"
15' 11"
16' 6"
4' 6"36' 11"
Doorway to be sealed
Doorway to be sealed
2nd FL Room 206
TELCOMM
Room
12 strands SM / ST from 206 to B53 (approx. 500' feet with service loops)
Outside 311th MI controlled spaces
1265081548C Rectangle
1265081548C Rectangle
1265081548C Text Box B.600 Basement
1265081548C Callout New IDS Install for MI
1265081548C Callout COM Closet
1265081548C Polygonal Line
1265081548C Callout Conduit from Secure Area to Secure COM room, 3/4" Rigid. CAT6 Shielded.
14'-4
" 12'-2"
18'-4
9'-6" 13'-5"
7'-11"62'-0"
13'-11" 9'-5"
8'-1
8'-9" 14'-4"
11'-9"
4'-1"
B50 B52 B54 B56 B58
B57B55B53B51B49BATHROOMS
S T
O R
A G
E
A
B
C
D
E
F
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
N o
D A
T E
D E
S C
R I P
T I O
N B
Y
P R
O J E
C T
M
A N
A G
E R
D E
S I G
N E
D
B
Y
D
H J Z
H
X
X X
X X
X
XX
SHEET OF
SHEET REFERENCE
R E
V I S
I O
N S
D R
A W
N
B
Y
A N
S I
P L O
T
S
C A
L E
I N
V O
I C
E
N
U M
B E
R
R E
P A
I R
E N
O V
A T
E
B
A S
E M
E N
T
B
L D
G
J B
E R
F
O R
T
R
I C
H A
R D
S O
N
A
L A
S K
A
D R
A W
I N
G
S
C A
L E
D A
T E
A
F
P
R O
J E
T
N
U M
B E
R
F
O N
T R
A C
T
N
U M
B E
R
A E
C
F
I L E
M
E
R A
N D
Y
T
Y L E
R
C H
I E
F r d
C
E S
C
E P
M R
S
A
I
R
E
X X
D
E C
V
C
A B
L E
V
R
N W
E L L
V
C
A B
L E
P
A
X U
P
S
T
E D
X
A-101
A R
C H
I T
E C
T U
R A
L
C O
N S
T R
U C
T I O
N
P
L A
N
A D d w g
NOT FOR CONSTRUCTION
SITE LOCATION
INFILL WALLS WHERE DOORS HAVE BEEN REMOVED.
BLOCK WALL INFILL AFTER REMOVAL OF ALL WINDOWS.
INSTALL NEW DOORS AND HARDWARE, INCLUDING CLOSURES PER
DRAWING AND SPECIFICATIONS.
INSTALL NEW 2' X 2" CEILING GRID WITH SUPER DUPER SILENCING.
INSTALL NEW GYP BOARD AND PAINT ON ALL WALLS SHOWN
INSTALL VINYL BASEBOARD THROUGHOUT.
INSTALL NEW FIXTURES: TOILETS, URINALS, LAVATORIES, MOP SINK,
RESTROOM PARTITIONS.
INSTALL NEW CARPET IN ROOMS B49 THROUGH B58
CONSTRUCTION NOTES
SCALE: 1/4" = 1'
NEW FLOOR PLAN
03 04
1213 11
09 08
1 1
2 2 2 2
22 22
3 3 3
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
OPEN TO BELOW
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
1265081548C Text Box
KEY
- Entrance
- Emergency Exit Only
- Arm/Disarm w/Duress
- Motion, Curtain 24x7
- Motion, 360
- HSS (BMS) Doors with HSS and Curtain will be combined alarms.
- Existing Alarm Rack
- Large Pull Box, Secured
- Alarm Panel
1265081548C Oval
1265081548C Oval
1265081548C Rectangle
1265081548C Polygon
1265081548C Oval
1265081548C Rectangle
1265081548C Rectangle
1265081548C Oval
1265081548C Rectangle
1265081548C Rectangle
1265081548C Oval
1265081548C Oval
1265081548C Oval
1265081548C Oval
1265081548C Oval
1265081548C Oval
1265081548C Oval
1265081548C Oval
1265081548C Oval
1265081548C Oval
1265081548C Oval
1265081548C Polygonal Line
1265081548C Polygonal Line
1265081548C Polygonal Line
1265081548C Rectangle
1265081548C Rectangle
1265081548C Rectangle
1265081548C Rectangle
1265081548C Polygonal Line
1265081548C Polygonal Line
1265081548C Callout Conduit to COM Room
| ARO B600 ISP Network Cable Installation Diagram |
| ARO B600 Open Storage Enclosures |
| Sheets and Views |
| NEW |
File details come from the government source that posted it. Updated .