This document is the Quality Assurance (QA) requirements for a supplier providing items or services for the Argonne National Laboratory (ANL) Advanced Photon Source Upgrade (APS-U) Pulsed Septum Magnet project.
The QA requirements cover conformance to the purchase order, rights of access for ANL, supplier quality management system, environmental protection, key personnel, manufacturing plan, inspection and testing, shipment, and acceptance criteria. Specific requirements include providing a quality assurance plan, listing manufacturing processes and inspection activities, obtaining approval for changes, performing dimensional and functional inspections, and providing certificates of conformance and calibration records. The supplier must also have processes to prevent delivery of suspect/counterfeit items. Additional requirements are specified for fasteners, lifting devices, pressure components, and welding. The document indicates that ANL will perform further acceptance testing after delivery, which could take up to 30 days before payment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| APPENDIX D-8-C.pdf | ||
| Septum Chamber Weldment Drawing.pdf | ||
| Appendix A-71COM-13-FEB-2023 (002).pdf | ||
| Septum FFT Drawing Package.pdf.pdf | ||
| Pulsed_Septum_FFT_AD_SOW.docx | DOCX document | |
| Pulsed_Septum_Inconel_AD_SOW.docx | DOCX document | |
| Reps Certs ANL 70A.doc | DOC document | |
| APS Upgrade Project ANL-407.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1.0 Applicability: APS-U Pulsed Septum Magnet
1.1 Scope: This document, when included in the Laboratory purchase order, establishes the quality assurance requirements that the supplier must provide. The quality requirements in this document can be modified by contacting the Laboratory Procurement Department prior to the award of the Laboratory purchase order.
2.0 DEFINITIONS:
2.2 Laboratory: UChicago Argonne LLC, acting by and through its Procurement Department issuing the purchase order.
2.3 Supplier: The legal entity which is the contracting party with the Laboratory in respect to the purchase order.
2.4 Sub-tier Supplier: a member of a supplier’s direct or indirect sub-tier supply base (including, without limitation, subcontractors and vendors of a supplier, and of a supplier’s subcontractors and vendors) that provides goods and/or services in connection with item(s) being procured.
2.5 Suspect/Counterfeit Item: An item where inspection or testing indicates it may not conform to established Government or industry-accepted specifications or national consensus standards or whose documentation, appearance, performance, material, or other characteristics may have been misrepresented. The types of items known to have been misrepresented include fasteners; hoisting, rigging, and lifting equipment; cranes; hoists; valves; pipe and fittings; electrical equipment and devices; plate, bar, shapes, channel members, and other heat treated materials and structural items; welding rod and electrodes; and computer memory modules.
3.1 Conformance to Requirements: All items or services furnished shall conform with the requirements of the Laboratory's purchase order. No change(s) shall be made without prior written approval of the Laboratory.
2.1 Purchase Order: The Argonne purchase order, contract, Blanket Agreement, subcontract or other written agreement with the supplier in which the requirements of this document are incorporated by reference.
3.0 GENERAL QUALITY REQUIREMENTS:
4.0 ADDITIONAL QUALITY REQUIREMENTS: The following requirements apply unless otherwise specified in the purchase order or statement of work.
3.2 Rights of Access: The Laboratory or its authorized representatives shall be afforded rights of access to the supplier and its sub-tier suppliers for the purpose of performing records reviews, surveillances, inspections, source verifications, or other activities associated with this procurement. The Laboratory will will be responsible for notifying the supplier at least 72 hours in advance of an activity.
3.3 Audit by Argonne: The supplier is subject to audit(s) by the Laboratory for conformance with the requirements of the purchase order. The Laboratory will will be responsible for notifying the supplier at least 72 hours in advance of the audit.
3.4 Responsibility for Conformance: Audits, surveillances verifications, inspections and/or tests made by the Laboratory, or its representative(s), shall not relieve the supplier of the responsibility to furnish items or services which conform to the requirements of the purchase order
3.5 Suspect/Counterfeit items: The supplier shall have a process for preventing the delivery of suspect/counterfeit items to the Laboratory or its designated delivery locations.
4.1 Supplier Quality Management System: The supplier shall provide items and services in accordance with a documented quality management system that is compliant with ISO 9001:2008 or 2015.
4.2 Supplier Quality Program for Partner Laboratories: The supplier shall provide items and services in accordance with a documented quality assurance program that complies with DOE Order 414.1 D.
4.5 Supplier Quality Assurance Plan: The suppler shall provide a copy of its quality assurance plan with its proposal.
4.3 Supplier Environmental Protection Program: The supplier shall provide items and services in accordance with a documented Environmental Protection Program that is compliant with the applicable national or international standards.
4.9 Supplier Key Personnel: The supplier shall provide the names and titles of the key personnel necessary for meeting the requirements Laboratory's purchase order. The supplier shall provide the information with its proposal.
4.10 Supplier Subcontractors: The supplier shall provide the names and addresses of the subcontractors it intends to use for meeting the requirements of the Laboratory purchase order. The supplier shall provide the information with its proposal.
4.11 Supplier Manufacturing Plan: The supplier shall submit a manufacturing plan identifying the manufacturing and inspection activities necessary for ensuring that quality will be achieved. The plan shall be submitted for the Laboratory's approval at least ten (10) working days prior to the start of manufacturing.
4.13 Supplier Measuring and Test Equipment List: The supplier shall provide a list of measuring and test equipment it intends to use for acceptance testing. The list shall contain the name and model number, and the date the equipment was last calibrated. The supplier shall include the list with its proposal.
4.14 Hold Points: The Laboratory reserves the right to specify hold points in the manufacturing process for the verification of quality requirements, delivery schedule, or other supplier activities. The supplier shall notify the Laboratory at least 72 hour (or other time frames stipulated by the Laboratory) in advance of reaching such points during the manufacturing process. The supplier shall not proceed past the hold point(s) without prior authorization from the Laboratory.
4.12 Supplier Proposed Changes: Prior to a change in a Laboratory’s approved design, workmanship standards, or manufacturing processes, the supplier shall submit the changes for Laboratory approval using a Supplier Disposition Request form included with the purchase order.
Advanced Photon Source Upgrade Project Procurement Quality Requirements form
ANL-407-APSU (10/26/2021) Page 1 of 3 (APS_2016776)
5.0 SHIPMENT:
6.0 LABORATORY ACCEPTANCE CRITERIA:
5.1 Protection of Material and Equipment: The supplier shall ensure adequate protection of material and equipment during shipment/storage, and shall include special environmental packaging, as necessary.
4.25 Process Control System: The supplier shall apply a system for controlling the sequence of manufacturing, inspection, and test activities through the use of travelers, tags, stamps, routing cards or other similar means.
4.15 Progress Meetings. The supplier shall participate in meetings or teleconferences with Laboratory personnel for the purpose of reviewing the supplier's progress, and for the discussion of manufacturing and scheduling issues. The meetings shall be conducted on a bi-weekly basis or at other times agreed to by the Laboratory and the supplier.
4.16 Supplier Progress Reports: The supplier shall submit progress reports during the execution of the purchase order. The progress reports shall include a summary of work that has been completed, work scheduled to be completed, and problems that may impact delivery.
4.17 Use of Advanced Photon Source Engineering Drawings: The supplier shall not manufacture to Advanced Photon Source engineering drawings unless the release level in the drawing title block is "Released" and the drawings are stamped "Construction".
4.21 US Grade 5,8 or Metric Grade 8.8-12.9 Fasteners: High strength fasteners shall be manufactured in accordance with an applicable national or international standard and under the control of a certified quality management system. The fasteners shall not have Head Markings shown on the Suspect/Counterfeit Bolt Head mark List included in the Laboratory Terms and Conditions Document.
4.22 Lifting Devices: The supplier shall provide lifting devices that are designed and manufactured in accordance with ASME B30.20 or equivalent standards. When used, the equivalent standards shall be submitted for approval by the Laboratory. Lifting Hooks shall be marked with Manufacturer Marking, Rated Capacity, Serial Number, Lifting Device Weight (if over 100 lbs.), and Rated Capacity. Elecrtically powered lifting devices shall be listed by a Nationally Recognized Testing Laboratory (NRTL) shown at https://www.osha.gov/dts/otpca/nrtl/nrtlmrk.html by a (or equivalent)
4.23 Pressure Components: The supplier shall provide pressure containing components that are designed or manufactured in accordance with the ASME Boiler and Pressure Vessel Code, ASME B31 series piping codes, or equivalent national or international standards. When equivalent national or international standards are used, the required level of safety, greater than or equal to that of the corresponding ASME codes, shall be documented and submitted for approval by the Laboratory prior to shipment. The supplier shall provide a certificate of conformance to the particular code followed.
4.32 Qualification of Supplier Personnel: Supplier personnel, processes, and equipment used to perform special processes such as precision machining, welding, brazing, inspection, testing, or other specialized tasks shall be properly qualified. Records of the qualification shall be maintained by the supplier and provided to the Laboratory upon request.
4.33 Certification of Supplier Personnel:: Supplier personnel performing special processes such as welding, brazing, inspection, testing, or other special processes shall be certified by formal testing to assure proficiency. The certification shall identify the period for which the certification is effective and be signed by and authorized supplier representative. Personnel shall be recertified through retesting before their certification expires. Records of the certifications shall be available to Argonne upon request.
4.35 Weld Samples: The supplier shall provide samples of typical weld joints and submit them to the Laboratory for approval prior to the start of welding. The samples shall be developed using the same materials and processes to be used on the final products.
4.36 Calibrated Measuring and Test Equipment: The supplier shall ensure that calibrated measuring and test equipment is used for acceptance testing. The calibration shall be in accordance with the equipment manufacturer's specifications, or other approved documents, and is traceable to the U.S. National Institute of Standards and Technology or equivalent standards laboratory.
4.37 Visual Inspection: The supplier shall perform visual inspection as specified in the purchase order or its associated documents. The supplier shall provide a documented inspection report when required by section 4.53 of this document.
4.38 Dimensional Inspection: The supplier shall perform dimensional inspection as specified in the purchase order or its associated documents. The inspection shall be performed using calibrated equipment and at a temperature of 20°C (68°F). Measurements performed at temperatures other than 20°C (68°F) shall be approriately compensated. The supplier shall provide a documented inspection report when required by section 4.53 of this document.
4.39 Functional Testing: The supplier shall perform functional testing as specified in the purchase order or its associated documents. The supplier shall provide a documented test report when required by section 4.53 of this document.
4.42 Leak Testing: The supplier shall perform leak testing as specified in the purchase order or its associated documents. The supplier shall provide a documented test report when required by section 4.53 of this document.
4.53 Inspection and Test Reports: The supplier shall provide documented reports to the Laboratory for the inspection and testing activities specified above. The reports shall be traceable to the item provided and contain the date that the inspection or test was performed, and the signature and title of the individual that performed the inspection or test.
4.56 Certificate of Conformance: The supplier shall provide a Certificate of Conformance stating that the items and services being provided conform to the requirements of the purchase order and its associated documents. The certificate shall contain the applicable part numbers, procedures, signature of the supplier’s authorized representative, the date that the certificate was approved, and the Laboratory purchase order number
4.58 Calibration Records: The supplier shall provide records for the measurement and test equipment used to determine the acceptability of the product being provided to the Laboratory. The records shall contain the equipment name, model number and serial number if applicable, the calibration date, the applicable calibration procedures, and the serial numbers of the calibration standards. The calibration standards shall be traceable to the U.S. National Institute of Standards and Technology or equivalent standards laboratory.
5.2 Documentation to be Provided with Shipment: The supplier shall provide the documents specified in this document or the Laboratory purchase order with each shipment.
5.4 Shipment to the Laboratory: Items shall be shipped to the Laboratory as specified in the purchase order.
ANL-407-APSU (10/26/2021) Page 2 of 3 (APS_2016776)
6.1 Basic Acceptance Criteria: The items provided will be inspected for compliance to the Laboratory purchase order following delivery. Items that are found to be nonconforming may be returned at the supplier's expense. The basic criteria for Laboratory acceptance is shown below.
- No Shipping damage
- Correct quantity
- No Suspect/Counterfeit items
- Overall conformance to the purchase order
6.3 Additional Testing to be Performed by the Laboratory: Additional testing will be performed by the Laboratory. The testing is estimated to last a minimum of 30 days after recieving before the supplier’s invoice can be paid.
ANL-407-APSU (10/26/2021) Page 3 of 3 (APS_2016776)