Appendix I_Dreamscape ccd fip 9-17-25.pdf
PDF 8 MB Posted
- Solicitation number
- IFB1 GMAA 2026000184 4
- Issued by
- Denver County, Denver City, Colorado
About this file
This design and construction document is prepared by Dreamscape Learn for the Community College of Denver's Cherry Creek Building, detailing the technical specifications and layout for an immersive learning laboratory facility. The project encompasses a 31-user immersive classroom (30 students plus 1 instructor), a free-roam pod, front-of-house operations space, and an Intermediate Distribution Frame (IDF) room. The immersive classroom includes student desks and chairs, pendant-mounted unistrut infrastructure, floor boxes with integrated power and data connectivity, a classroom cabinet rack, lower cameras, and cable tray systems. The free-roam pod features a lighting truss, raised floor platform, pod rack, and scene station controller. All electrical systems include multiple duplex and quad 5-20R receptacles at specified heights, with overhead power outlets for lighting and lower power outlets for equipment charging and device connectivity. Data infrastructure consists of CAT6 and CAT4 keystone jacks distributed throughout the facility, with single-mode fiber connectivity (6 strands with LC connectors) connecting the classroom spaces to the IDF room. The document was issued on September 17, 2025, and provides detailed dimensional specifications and equipment mounting heights throughout the facility.
Responsibility for furnishing and installing components is distributed among multiple parties: Dreamscape Learn (DSL) supplies student furniture, lower cameras, pod lighting truss, and raised floor; the General Contractor (GC) provides pendant-mounted unistrut, floor boxes, cable tray, fiber terminations, and ramp/platform construction; and the Low Voltage (LV) Contractor supplies scene station controllers, DMX wall plates, and associated wiring. The IDF room accommodates a render server with a 42,000 BTU heat load and includes ladder rack-mounted power distribution (four L6-30R whips) and fiber termination panels at specified heights. All power and data cabling terminations are detailed with specific mounting heights and circuit-sharing provisions to optimize electrical infrastructure efficiency throughout the facility.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A.
D re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
TA
B
LE
O F
C O
N
TE
N
TS
DSL- COMMUNITY COLLEGE OF DENVER- FREE ROAM POD - 30+1 USER CLASSROOM
A.01- IMMERSIVE CLASSROOM FLOOR PLAN
A.02- IMMERSIVE CLASSROOM FLOOR BOX PLAN
A.03- IMMERSIVE CLASSROOM FLOOR BOX DIMENSIONS
A.04- IMMERSIVE CLASSROOM UNISTRUT PLAN
A.06- IMMERSIVE CLASSROOM OVERHEAD POWER AND DATA PLAN
A.07- IMMERSIVE CLASSROOM LOWER POWER AND DATA PLAN
A.08- CLASSROOM CABINET DETAIL
A.09- NETFLOOR FLOOR BOX DETAIL
A.10-SCENE STATION DETAIL
A.11- PULL BOX DETAIL
A.12- FRONT OF HOUSE PLAN
A.13- GUGD CUBBIES DETAIL
A.14- FREE ROAM POD PLAN
A.15- FREE ROAM POD OVERHEAD POWER AND DATA PLAN
A.16- FREE ROAM POD LOWER POWER AND DATA PLAN
A.17- IDF PLAN
A.18- IDF POWER PLAN
A.19- IDF DATA PLAN
A.20- IDF LADDER RACK PLAN
A.01 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
O
V E
R A
LL
FL
O O
R P
LA
N
Jacob Fowler
IDF
Jacob Fowler
IMMERSIVE CLASSROOM
31 USERS (30+1)
Jacob Fowler
FREE-ROAM POD
Jacob Fowler
FRONT OF HOUSE
A.02 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
IM
M E
R S
IV
E
C
LA
S
S R
O O
M
FL
O O
R P
LA
N
STUDENT DESK AND CHAIR
FURNISHED AND INSTALLED BY DSL
PENDANT MOUNTED UNISTRUT
FURNISHED AND INSTALLED BY GC
FLOOR BOXES
FURNISHED AND INSTALLED BY GC
SCENE STATION
FURNISHED AND INSTALLED BY LV CONTRACTOR
LOWER CAMERAS
FURNISHED AND
INSTALLED BY DSL
CABINET RACK
FURNISHED AND
INSTALLED BY
DSL
CLASSROOM CABINET
FURNISHED AND
INSTALLED BY DSL
CABLE TRAY
FURNISHED AND
INSTALLED BY GC
A.03 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
FL
O O
R B
O X
P
LA
N
PURPLE FLOOR BOX TYPICAL:
4 GANG, FLUSH MOUNTED
POWER: (2) DUPLEX 5-20R
(CAN SHARE CIRCUIT WITH
NEIGHBORING BOX)
DATA: (6) CAT6 KEYSTONE JACKS
TERMINATED TO PATCH PANEL
IN CABINET RACK
CABLING BY GC
RED FLOOR BOX TYPICAL:
2 GANG, FLUSH MOUNTED
POWER: (1) DUPLEX 5-20R
(CAN SHARE CIRCUIT WITH
NEIGHBORING BOX)
DATA: (4) CAT4 KEYSTONE JACKS
TERMINATED TO PATCH PANEL
IN CABINET RACK
CABLING BY GC
CABINET RACK:
ALL FLOOR BOX DATA CABLING
TERMINATED TO PATCH PANEL
IN CABINET RACK. CABLING BY GC
A.04 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
FL
O O
R B
O X
D
IM
E N
S
IO
N S
5'-2" 5'-2" 5'-2" 6'-7"
8' -1
0"
6'-7"5'-2" 5'-2" 5'-2"
15'-0"15 '-0
'-9
/4
'-5
/2
8'
-1 0"
8' -9
" 6'-4 3/4"
8' -9
8' -9
5'-6 3/4" 8'-8"
5' -2
5' -2
14'-9 3/4"
'-1
7'-2 3/4" 8'-10"
8' -1
1/
2"
'-4
/2
'-1
1/
2"
8' -1
0"
8' -1
0"
A.05 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
U
N
IS
TR
U
T P
LA
N
-UNISTRUT NOTES;
-ALL UNISTRUT TO BE BLACK
-UNISTRUT DIMS- 1-5/8” X 1-5/8”
-UNISTRUT MOUNTED ON 1/2” THREADED ROD HANGERS
-THREADED ROD MOUNTED EVERY 4’
-UNISTRUT MOUNTED WITH SLOTTED CHANNEL FACING FLOOR
-UNISTRUT MOUNTED AT 9’-6”AFF
24'-6 3/4"
'-2
/4
8'-9" 14'-5"
5'-1/2" 5'-1/2" 5'-1/4" 3'-6"
3' -4
/4
3'
-4
/4
'-4
/4
4' -6
5' -9
/2
" 6" 6"
6"
2'-10"
6"
6"
'-8
/4
2' -1
6"
2'-9 1/2"
6"
6"
6"
CABLE TRAY-
6” WIDE X 2.38 DEEP X
'-9
A.06 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
O
V E
R H
E A
D P
O W
E R
A N
AT
A P
LA
N
DUPLEX 5-20R AT CEILING
HEIGHT FACING FLOOR
FOR LIGHTING POWER
CAN SHARE CIRCUIT WITH
NEIGHBORING RECEPTACLE
DUPLEX 5-20R AT CEILING
HEIGHT FACING FLOOR
FOR LIGHTING POWER
CAN SHARE CIRCUIT WITH
NEIGHBORING RECEPTACLE
DUPLEX 5-20R AT CEILING
HEIGHT FACING FLOOR
FOR LIGHTING POWER
CAN SHARE CIRCUIT WITH
NEIGHBORING RECEPTACLE
DUPLEX 5-20R AT CEILING
HEIGHT FACING FLOOR
FOR LIGHTING POWER
CAN SHARE CIRCUIT WITH
NEIGHBORING RECEPTACLE
J1 3PIN DMX WALL PLATE-
FURNISHED AND INSTALLED
BY LV CONTRACTOR
(SEE PAGE A.09 FOR DETAIL)
Q1 DMX SCENE STATION
CONTROLLER FURNISHED AND
INSTALLED BY LV CONTRACTOR
( SEE PAGE A.09 FOR DETAIL)
A.07 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
LO
W E
R P
O W
E R
A
A P
LA
N
QUAD 5-20R AT 18”AFF
FOR CABINET RACK POWER
QUAD 5-20R AT 18”AFF
FOR CHARGING
SM FIBER TO IDF:
6 STRANDS TERMINATED TO
LC CONNECTORS
TERMINATIONS TO BE MADE INTO
SINGLE PANEL HOUSING AT 16”AFF
BY GC
A.08 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
C
LA
S
S R
O O
M
C A
B
IN
E T
D E
TA
IL
PATCH PANELS
SM FIBER SINGLE
PANEL HOUSING
A.09 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
N
E
TF
LO
O
R
FL
O O
R B
O X
TA
IL
A.10 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
S
C E
N E
S
TA
TI
O
N D
E
TA
IL
1’-0”1’-0”
4’ -0
SCENE STATION MOUNTED
AT 48” AFF AND 12” FROM
DOORWAY
Q1 DMX SCENE STATION CONTROLLER
FURNISHED AND INSTALLED BY
LV CONTRACTOR
CONDUIT FROM SCENE STATION
TO 3-PIN DMX WALL PLATE
DROP CEILING
J1 3-PIN DMX WALL
PLATE- FURNISHED
AND INSTALLED BY
LV CONTRACTOR
MOUNTED ABOVE ACT
INTERACTIVE TECHNOLOGIES
AC-CL2T-120B12
12V BOX AC TRANSFORMER
SCENE STATION DETAIL
3 PIN DMX WALL PLATE DETAIL
12V BOX AC TRANSFORMER
DETAIL
SCENE STATION CONTROLLER, 3 PIN DMX WALL PLATE,
TRANSFORMER, AND ALL WIRING
BY CUSTOMERS ELECTRICIAN OR LV CONTRACTOR
A.11 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
P
U
LL
B O
X D
E
A.12 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
FR
O N
T O
F H
O U
S E
P
LA
N
QUAD 5-20R at 18”AFF
CAN SHARE CIRCUIT
WITH NEIGHBORING
RECEPTACLES
QUAD 5-20R at 18”AFF
CAN SHARE CIRCUIT
WITH NEIGHBORING
RECEPTACLES
TBD: RED FLOOR BOX
(2) DUPLEX 5-20R
(4) CAT 6 CABLES
FOR DEV STATION
POWER AND DATA
QUAD 5-20R TYP AT 43” AFF
CAN SHARE CIRCUIT WITH
NEIGHBORING RECEPTACLE
FOR GUGD POWER
A.13 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
G
U G
D C
U B
B
IE
S D
E
A.14 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
FR
E E
R O
A M
P O
D P
LA
N
LIGHTING TRUSS
FURNISHED AND INSTALLED BY DSL
TAIT RAISED FLOOR
FURNISHED AND INSTALLED BY DSL
RAMP AND PLATFORM
FURNISHED AND INSTALLED
BY GC
POD RACK
FURNISHED AND
INSTALLED BY DSL
SCENE STATION
FURNISHED AND INSTALLED
BY LV CONTRACTOR
A.15 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
O
V E
R H
E A
D P
O W
E R
A
A P
LA
N
DUPLEX 5-20R AT 12’AFF
FOR OVERHEAD LIGHTING
CAN SHARE CIRCUT WITH
NEIGHBORING RECEPTACLE
DUPLEX 5-20R AT 12’AFF
FOR OVERHEAD LIGHTING
CAN SHARE CIRCUT WITH
NEIGHBORING RECEPTACLE
J1 3PIN DMX WALL PLATE- FURNISHED
AND INSTALLED BY LV CONTRACTOR
(SEE PAGE A.09 FOR DETAIL)
Q1 DMX SCENE STATION CONTROLLER
FURNISHED AND INSTALLED BY LV CONTRACTOR
( SEE PAGE A.09 FOR DETAIL)
A.16 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
LO
W E
R P
O W
E R
A
A P
LA
N
QUAD 5-20R TYP AT 48” AFF
CAN SHARE CIRCUIT WITH
NEIGHBORING RECEPTACLE
FOR GUGD POWER
QUAD 5-20R TYP AT 48” AFF
CAN SHARE CIRCUIT WITH
NEIGHBORING RECEPTACLE
FOR GUGD POWER
QUAD 5-20R TYP AT 48” AFF
CAN SHARE CIRCUIT WITH
NEIGHBORING RECEPTACLE
FOR GUGD POWER
QUAD 5-20R TYP AT 48” AFF
CAN SHARE CIRCUIT WITH
NEIGHBORING RECEPTACLE
FOR GUGD POWER
PROVIDE L21-30R
AT 18”AFF
SM FIBER TO IDF:
6 STRANDS TERMINATED TO LC CONNECTORS
TERMINATIONS TO BE MADE INTO SINGLE
PANEL HOUSING AT 16”AFF BY GC
8' -6
3'-9"
PLATFORM AT 8” AFF
A.17 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
ID
F P
LA
N
4' -0
2'-5 1/2"
RENDER SERVER
HEAT LOAD:
42,000 BTU
A.18 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
ID
F P
O W
E R
P
LA
N
(4) L6-30R WHIP
MOUNTED TO LADDER RACK
AT 84” AFF
A.19 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
ID
F D
AT
A
P
LA
N
SM FIBER TO IMMERSIVE CLASSROOM
6 STRANDS TERMINATED TO LC CONNECTORS
TERMINATIONS TO BE MADE INTO SINGLE
PANEL HOUSING MOUNTED TO
LADDER RACK AT 84” AFF BY GC
A.20 re am sc ap e
Le ar n D es ig n, C on st ru ct io n, En gi ne er in g
B uc ki ng ha m P kw y
C ul ve r C ity , C
A
C O
M M
U N
IT
Y
C O
LL
E
G E
O F
D E
N V
E R
C H
E R
R Y
C R
E E
K B
U
IL
D
IN
G
W
C ol fa x
Av e, D en ve r, C O
IS
S
U E
9/
/2
ID
F
LA
D D
R
R
A C
K P
LA
N
9'-7 1/4"
1' -0
LADDER RACK MOUNTED AT 84”
AFF
4' -1
/2
6' -1
/4
File details come from the government source that posted it. Updated .