Appendix C_Table Interior Surface Decontamination.xlsx
XLSX spreadsheet 30 KB Posted
- Solicitation number
- 70Z088-26-Q-A7E001
About this file
This file is an Interior Surface Decontamination Appendix Table that details room-by-room specifications for asbestos remediation work at USCG Station Channel Islands in Oxnard, California. The spreadsheet itemizes 50+ interior spaces across two decks, specifying square footage, ceiling heights, floor types, and ceiling configurations for each location. Key data columns include horizontal surface cleaning square footage, vertical wall surface area, window and door components, interior fixtures requiring remediation, and general notes identifying specific concerns such as improperly fitted T-bar ceiling tiles, sealed ceiling registers, exposed utility ductwork, and gaps in ceiling installations requiring closure.
The table establishes baseline measurements and decontamination requirements across diverse room types including berthing areas, galleys, heads (bathrooms), mechanical rooms, office spaces, common areas, and storage closets. Total cleaning specifications aggregate to approximately 7,900 square feet of occupied spaces, 6,942 square feet of vertical wall surfaces, 8,742 square feet of interior building components/fixtures, and 19,004 square feet of additional remediation tasks. Special attention areas include exhaust ductwork removal in multiple heads and laundry rooms, insulation removal in mechanical/utility closets with excessive utility components, and structural gaps requiring sealing. This appendix serves as the detailed scope baseline for contractors bidding on the remediation phase I contract to establish labor estimates, material requirements, and project scheduling.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Interior surface
| Floor | Room / Location | Room (SF) | Ceiling Height | Floor Type | Ceiling Plenum Utility Components Cleaning SF | Ceiling Plenum Concrete to be Cleaned | Ceiling Type to be Removed/ Cleaned | T-Bar Ceiling Removal SF | Occupied Spaces: Horizontal Surface Cleaning SF | Wall Type | Occupied Spaces: Vertical Surface area Cleaning Walls/Baseboard SF | Windows & Window Components SF | Door & Door Components SF | Interior Building Components/ Fixtures | Interior Building Components/ Fixtures SF | General Notes |
| 1st | Reserve Berthing | 223.3 | 8 | Glue down Carpet | 156.31 | 223.3 | T-Bar 2' x 4' Fissured Ceiling Tiles | 223.3 | 223.3 | Brick/ Drywall | 479.4 | 60 | 48 | Ceiling register, wall register, light panel. smoke detector, speaker box, ceiling speakers, light switches. | 30 | Missing & Improperly fitted T-Bar ceiling tiles -8 SF. Ceiling registers are sealed with plastic. |
| 1st | First Class Berthing | 182 | 8 | Glue down Carpet | 127.4 | 182 | T-Bar 2' x 4' Fissured Ceiling Tiles | 182 | 182 | Painted Brick/ Drywall | 432 | 60 | 48 | Ceiling register, wall register, light panel. smoke detector, speaker box, ceiling speakers, light switches. | 30 | Improperly fitted T-Bar ceiling tiles. Ceiling registers are sealed with plastic. |
| 1st | Laundry Room | 32 | 8 | Ceramic Tile | 22.4 | 32 | T-Bar 2' x 4' Fissured Ceiling Tiles | 32 | 32 | Drywall | 222.4 | - | - | Smoke detector, Exhaust ducting | 10 | Dryer-Exhaust ducting to be removed. |
| 1st | Common Area | 54 | 8 | Ceramic Tile | 37.8 | 54 | T-Bar 2' x 4' Fissured Ceiling Tiles | 54 | 54 | Drywall | 208 | - | 60 | Light fixture, ceiling register | 15 | - |
| 1st | Unisex Head | 116.2 | 8 | Ceramic Tile | 81.34 | 116.2 | Hard Lid- Drywall | - | 116.2 | Drywall/ Ceramic | 348.8 | - | 48 | Ceiling Light, Shower, toilet, Partition walls, Sinks, Countertops, Locker, mirror, paper towel dispenser, Exhaust Fan, light switches. | 300 | Ceiling Exhaust /ducting to be cleaned/ removed. |
| 1st | Female Berthing | 210 | 8 | Glue down Carpet | 147 | 210 | T-Bar 2' x 4' Fissured Ceiling Tiles | 210 | 210 | Painted Brick/ Drywall | 464 | 60 | 48 | Ceiling & Wall registers, Smoke alarm, speakers, light panels, ceiling fan, light switches. | 50 | - |
| 1st | Female Berthing Restroom | 39.6 | 8 | Ceramic Plank | 27.72 | 39.6 | Hard Lid- Drywall | 39.6 | 39.6 | Painted Brick/ Drywall | 200 | - | 48 | Mirror, Vanity, light fixtures, fixtures, shower, toilet , Exhaust fan, light switch. | 150 | Ceiling Exhaust /ducting to be cleaned/ removed. |
| 1st | Rec Room | 229.5 | 8 | Glue down Carpet | 160.65 | 229.5 | T-Bar 2' x 4' Fissured Ceiling Tiles | 229.5 | 229.5 | Painted Brick/ Drywall | 488 | 30 | 60 | Ceiling registers, Smoke alarm, speakers, light panels, fire alarm , conduits, light switches. | 60 | Improperly fitted T-Bar ceiling tiles. Ceiling registers are sealed with plastic. |
| 1st | P-Way | 344 | 8 | Ceramic Tile | 240.8 | 344 | T-Bar 2' x 4' Fissured Ceiling Tiles | 344 | 344 | Cinder Block/ Drywall | 784 | 160 | 260 | Ceiling register, light panel. Smoke detector, speakers, signage, camera, fire alarm, EC panel. | 50 | 4'' gap where the T-bar ceiling meets the east exterior wall open to ceiling plenum above. |
| 1st | Training Room | 378 | 8 | Glue down Vinyl Flooring | 264.6 | 378 | T-Bar 2' x 4' Fissured Ceiling Tiles | 378 | 378 | Brick/ Panel | 624 | 160 | 48 | Ceiling registers, Smoke alarm, speakers, ceiling registers, light panels, light switches, fire alarms. | 150 | 4'' gap where the T-bar ceiling meets the west exterior wall open to ceiling plenum above. |
| 1st | Training Room Showcase | 36 | 5 | NA | 25.2 | 36 | NA | - | 72 | Glass/ Wood Case | 180 | 300 | - | Ceiling register, wall register, glass, wood. | 10 | Ventilation vents observed at the interior and exterior of the showcase. |
| 1st | Male Head | 161.5 | 8 | Ceramic Tile | 113.05 | 161.5 | Hard Lid- Drywall | - | 323 | Painted Brick/ Drywall | 440 | 20 | 48 | Ceiling lights, Exhaust fan, EC Box, Conduit, smoke alarm, countertops, partition walls, sinks, toilets, | 300 | Ceiling Exhaust /ducting to be cleaned/ removed. |
| 1st | Mop Closet | 20 | 9.6 | Ceramic Tile | 14 | 20 | Concrete Deck | - | 40 | Painted Brick/ Drywall | 172.8 | - | - | Ductwork, ceiling, sink, shelf, piping, | 150 | - |
| 1st | Armory | 115 | 8 | Hard Rubber Mat | 80.5 | 115 | Hard Lid- Drywall | - | 230 | Cinder Block | 344 | - | 48 | Ceiling register, interior metal ductwork, Speaker box, smoke alarm, gun racks, light fixtures, Exhaust | 100 | Ceiling Exhaust /ducting to be cleaned/ removed. |
| 1st | Female Head | 35 | 8 | Ceramic Tile | 24.5 | 35 | Hard Lid- Drywall | - | 70 | Cinder Block/ Drywall | 192 | - | 48 | Exhaust Fan, toilet, sink, light fixtures, mirror. | 60 | Ceiling Exhaust /ducting to be cleaned/ removed. |
| 1st | Gear Locker Room | 63 | 8 | Ceramic Tile | 44.1 | 63 | T-Bar 2' x 4' Fissured Ceiling Tiles | 63 | 63 | Cinder Block | 256 | - | 48 | Interior Lockers, Light panels, smoke alarm, light switched. | 300 | - |
| 1st | ME-Office | 130 | 8 | Painted Concrete | 91 | 130 | T-Bar 2' x 4' Fissured Ceiling Tiles | 130 | 130 | Cinder Block | 372.8 | - | 48 | Speaker box, smoke alarm, Light panel, ceiling register | 10 | - |
| 1st | Galley | 494 | 8 | Ceramic Tile | 345.8 | 494 | T-Bar 2' x 4' Fissured Ceiling Tiles | 494 | 494 | Drywall/ Brick | 720 | 15 | 48 | Metal duct to be cleaned and removed, Light fixtures, smoke alarm, speaker box, ceiling registers, countertops, cabinets, island counter | 900 | - |
| 1st | Common Area into Galley | 48 | 8 | Ceramic Tile | 33.6 | 48 | T-Bar 2' x 4' Fissured Ceiling Tiles | 48 | 48 | Drywall | 224 | - | - | Light fixtures, smoke alarm, speaker box, ceiling registers | 10 | - |
| 1st | Gym | 702 | 8 | Hard Rubber Gym Mat | 491.4 | 702 | T-Bar 2' x 4' Fissured Ceiling Tiles | 702 | 702 | Painted Brick/ Drywall | 848 | 230 | 48 | Ceiling registers, Smoke alarm, speakers, light panels, light switches, fire alarms. | 140 | 4'' gap where the T-bar ceiling meets the west exterior wall open to ceiling plenum above. |
| 1st | Stairwell | 152 | 9.6 | Ceramic Tile | 106.4 | 152 | T-Bar 2' x 4' Fissured Ceiling Tiles | 152 | 152 | Painted Brick/ Cinder Block | 432 | 15 | 80 | Stairs, treads, steps, handrails, light fixture, smoke alarm, conduit, EC Boxes | 400 | - |
| 1st | Storage Below Stairs | 32 | 8 | Ceramic Tile | 22.4 | 32 | NA | - | 64 | Painted Brick/ Cinder Block | 192 | - | 12 | Light switch, light fixture, smoke alarm. | 10 | - |
| 1st | Furnace 1, Mechanical Rm | 84 | 8 | Concrete | 58.8 | 84 | Concrete Deck | - | 168 | Cinder Block | 364.6 | - | 60 | Interior/ Exterior Furnace, mechanical components, Insulation, utility piping. | 600 | Exterior |
| 2nd | XPO Office | 183.4 | 8 | Glue down Vinyl Flooring | 128.38 | 183.4 | T-Bar 2' x 4' Fissured Ceiling Tiles | 183.4 | 183.4 | Painted Brick/ Drywall | 433.6 | 70 | 54 | Ceiling registers, light panels, smoke alarm, speakers | 100 | - |
| 2nd | EPO Office | 64.61 | 8 | Glue down Vinyl Flooring | 45.227 | 64.61 | T-Bar 2' x 4' Fissured Ceiling Tiles | 64.61 | 64.61 | Drywall | 259.2 | 80 | 90 | Ceiling registers, light panels, smoke alarm, speakers | 70 | - |
| 2nd | Command Head | 79.3 | 8 | Ceramic Plank/ Concrete | 55.51 | 79.3 | T-Bar 2' x 4' Fissured Ceiling Tiles | 79.3 | 79.3 | Drywall/ Ceramic | 294.4 | - | 54 | Light panels, smoke alarm, exhaust fan, toilet, counter, vanity, paper dispenser, urinal | 40 | Ceiling Exhaust /ducting to be cleaned/ removed. |
| 2nd | OIC Closet/ Storage | 58.5 | 9.6 | Vinyl Flooring | 40.95 | 58.5 | Concrete Deck | - | 117 | Painted Brick/ Drywall | 244.8 | - | 54 | Ductwork, light fixtures, smoke alarm, piping | 100 | - |
| 2nd | OIC Office | 231 | 8 | Vinyl Flooring | 161.7 | 231 | T-Bar 2' x 4' Fissured Ceiling Tiles | 231 | 231 | Painted Brick/Wood Panel/ DW | 486.4 | 125 | 30 | Ceiling registers, Smoke alarm, speakers, light panels, light switches, fire alarms. | 50 | - |
| 2nd | Conference Room | 267 | 8 | Vinyl Flooring | 186.9 | 267 | T-Bar 2' x 4' Fissured Ceiling Tiles | 267 | 267 | Painted Brick/ Drywall | 523.1 | 80 | 90 | Ceiling registers, light panels, smoke alarm, speakers, light switches | 50 | - |
| 2nd | Common Area at Conference | 89 | 8 | Glue down Vinyl Flooring | 62.3 | 89 | T-Bar 2' x 4' Fissured Ceiling Tiles | 89 | 89 | Drywall | 305.6 | - | 54 | Ceiling registers, light panels, smoke alarm, speakers | 10 | - |
| 2nd | Operations | 298 | 8 | Ceramic Tile/ Bare Concrete | 208.6 | 298 | T-Bar 2' x 4' Fissured Ceiling Tiles | 298 | 298 | Drywall/ Painted Brick | 558.4 | 80 | 54 | Ceiling registers, light panels, smoke alarm, speakers, cables, pipe. | 100 | - |
| 2nd | Communications | 194 | 8 | Vinyl Flooring | 135.8 | 194 | T-Bar 2' x 4' Fissured Ceiling Tiles | 194 | 194 | Drywall/ Painted Brick | 454.4 | 85 | 54 | Ceiling registers, light panels, smoke alarm, speakers | 40 | 4'' gap where the T-bar ceiling meets the west exterior wall open to ceiling plenum above. |
| 2nd | BM1 Office | 158 | 8 | Vinyl Flooring | 110.6 | 158 | T-Bar 2' x 4' Fissured Ceiling Tiles | 158 | 158 | Drywall/ Painted Brick | 420.8 | 110 | 54 | Ceiling registers, light panels, smoke alarm, speakers | 40 | 4'' gap where the T-bar ceiling meets the west exterior wall open to ceiling plenum above. |
| 2nd | North P-Way | 240 | 8 | Bare Concrete | 168 | 240 | T-Bar 2' x 4' Fissured Ceiling Tiles | 240 | 240 | Brick/ Drywall | 536 | - | 70 | Ceiling registers, light panels, smoke alarm, speakers, video, conduit, signage | 100 | 4'' gap where the T-bar ceiling meets the west exterior wall open to ceiling plenum above. |
| 2nd | South P-Way | 240 | 8 | Vinyl Flooring | 168 | 240 | T-Bar 2' x 4' Fissured Ceiling Tiles | 240 | 240 | Drywall/ Wood Panel | 736 | - | 35 | Ceiling registers, light panels, smoke alarm, speakers | 30 | - |
| 2nd | MAA Storage | 80 | 8 | Exposed Black Floor Mastic ACM | 56 | 80 | T-Bar 2' x 4' Fissured Ceiling Tiles | 80 | 80 | Drywall | 288 | - | 54 | Ceiling registers, light panels, smoke alarm, speakers | 30 | - |
| 2nd | Server Room | 80 | 8 | 12' Resilient Floor Tile ACM | 56 | 80 | T-Bar 2' x 4' Fissured Ceiling Tiles | 80 | 80 | Brick/ Drywall | 288 | 6 | 54 | Ductwork, Smoke Alarm, Conduit, Cables , Wood, Wiring Box, access door, ceiling register, cables, equipment, light panel, misc. items., ductwork, wood, | 500 | Missing & Improperly fitted T-Bar ceiling tiles -8 SF. Ceiling registers are sealed with plastic. |
| 2nd | Male Head | 236 | 8 | Ceramic Tile | 165.2 | 236 | Hard Lid- Drywall | - | 472 | Drywall/ Painted Brick | 508.8 | 8 | 54 | Ceiling lights, Exhaust fan, EC Box, Conduit, smoke alarm, showers, countertops, partition walls, sinks, toilets, ladder to roof. | 600 | Ceiling Exhaust /ducting to be cleaned/ removed. |
| 2nd | MK Berthing | 250 | 8 | Glue Down Carpet | 175 | 250 | T-Bar 2' x 4' Fissured Ceiling Tiles | 250 | 250 | Brick/ Cinder/ Drywall | 520 | 35 | 54 | Ceiling registers, light panels, smoke alarm, speakers, light switch. | 100 | - |
| 2nd | Rec. Room | 260 | 8 | Glue Down Carpet | 182 | 260 | T-Bar 2' x 4' Fissured Ceiling Tiles | 260 | 260 | Painted Brick/ Porous Wall Covering | 528 | 70 | 54 | Ceiling registers, light panels, smoke alarm, speakers, light switch. | 70 | North wall is padded with porous fabric. |
| 2nd | Non Rate Berthing | 250 | 8 | Glue Down Carpet | 175 | 250 | T-Bar 2' x 4' Fissured Ceiling Tiles | 250 | 250 | Brick/ Cinder/ Drywall | 520 | 35 | 54 | Ceiling registers, light panels, smoke alarm, speakers, light switch. | 70 | - |
| 2nd | E4/E5 Berthing | 250 | 8 | Glue Down Carpet | 175 | 250 | T-Bar 2' x 4' Fissured Ceiling Tiles | 250 | 250 | Brick/ Cinder/ Drywall | 520 | 35 | 54 | Ceiling registers, light panels, smoke alarm, speakers, light switch. | 70 | - |
| 2nd | OOD Berthing | 260 | 8 | Glue Down Carpet | 182 | 260 | T-Bar 2' x 4' Fissured Ceiling Tiles | 260 | 260 | Painted Brick/ Drywall | 528 | 70 | 54 | Ceiling registers, light panels, smoke alarm, speakers, light switch. | 70 | - |
| 2nd | Utility Closet Furnace # 2 | 49 | 9.6 | Concrete | 34.3 | 49 | Concrete Deck | - | 98 | Drywall/ Brick | 224 | - | 90 | Insulation removal interior Furnace, Insulation removal at ductwork, pipes, duct, utility, signs, wires, cables, misc. items, smoke alarm, light fixture, circuit board, wall mounted metal box systems | 500 | Excessive utility components within Utility Closet. |
| 2nd | Closet Furnace #3 | 15 | 8 | Concrete | 10.5 | 15 | Concrete Deck | - | 30 | Drywall | 128 | 30 | 156 | Furnace, pipes, duct, utility, signs, wires, cables, misc. items, smoke alarm, light fixture | 400 | Excessive utility components within Utility Closet. |
| 2nd | Laundry | 35 | 8 | Ceramic | 24.5 | 35 | T-Bar 2' x 4' Fissured Ceiling Tiles | 35 | 35 | Drywall | 192 | - | Smoke detector, Exhaust ducting | 15 | Dryer-Exhaust ducting to be removed. | |
| 2nd | Stair | 152 | 9.6 | Concrete | 106.4 | 152 | Concrete Deck | 152 | 152 | Painted Brick/ Cinder Block | 518.4 | - | 80 | - |
Totals 7900.91 5530.637 7900.91 6942.71 8742.91 19004.7 2029 2607 6990