Appendix A.pdf
PDF 586 KB Posted
- Solicitation number
- 36C26126R0023
About this file
This document is a water sample testing report and appendix from California Laboratory Services (CLS) detailing analytical results for samples submitted by Hyperion Biotechnology. The report covers testing of two water samples collected on March 5, 2025, from the Martinez facility: one from patient room #N123 and one from the sterilization room equipment wall port. Samples were received by the laboratory at 15:30 on March 5, 2025, and analyzed according to EPA and other ELAP-approved methodologies.
The analytical results encompass conventional chemistry parameters (fluoride, nitrate, specific conductance, sulfate, and total hardness), metals analyzed by EPA 200 Series methods (calcium, magnesium, potassium, and sodium), drinking water metals (aluminum, antimony, arsenic, barium, beryllium, cadmium, chromium, copper, lead, mercury, nickel, selenium, silver, thallium, and zinc), and microbiological parameters (plate count). Key findings include copper levels of 340 µg/L and 72 µg/L in the patient room and sterilization room samples respectively, with most other analytes either not detected or within acceptable ranges. The microbiological analysis showed plate counts of <1 CFU/mL in the patient room sample and 53 CFU/mL in the sterilization room sample. The report includes two revisions—the first dated March 17, 2025, added sodium, potassium, and magnesium analyses per client request, and the second dated March 18, 2025, added calcium analysis. Comprehensive quality control data, including blanks, laboratory control samples, matrix spikes, and duplicate analyses, are provided to demonstrate analytical validity. The laboratory holds CA SWRCB ELAP Accreditation/Registration number 1233.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S06-36C26126R0023 0001.pdf | ||
| 36C26126R0023_2.docx | DOCX document | |
| Attachment Request for Information RFI Form.pdf | ||
| SECTION 01 00 00.pdf | ||
| SECTION 22 67 19.16.pdf | ||
| Appendix B.pdf | ||
| WAGE DETERMINATION CA20260018 01-30-2026.pdf | ||
| Utility water sampling data.pdf | ||
| Basis of Design.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
09-01-15
22 67 19.16 - 1
SECTION 22 67 19.16
REVERSE-OSMOSIS WATER EQUIPMENT
Appendix A
Water sample testing report for reference purposes.
Enclosed are the results of analyses for samples received by the laboratory on 03/05/25
15:30. Samples were analyzed pursuant to client request utilizing EPA or other ELAP approved methodologies. I certify that the results are in compliance both technically and for completeness.
Analytical results are attached to this letter. Please call if we can provide additional assistance.
Sincerely, Daniel Johnson
Technical Director
CA SWRCB ELAP Accreditation/Registration number 1233
March 18, 2025
Alicia Richarte
Hyperion Biotechnology 12002 Warfield St. Suite 101 San Antonio, TX 78216
Project Name: Martinez Specialized Testing
CLS Work Order #: 25C0187
COC #:
3249 Fitzgerald Road, Rancho Cordova, CA 95742 | 800.638.7301 | Tel: 916.638.7301 x102 | Fax: 916.638.4510 | www.californialab.com
Small Business #2916 | ELAP #1233 | NAICS #541380 | CA SWRCB ELAP Accreditation/Registration Number 1233
Revision History
Client: Hyperion Biotechnology Work Order: 25C0187 Project Name: Martinez Specialized Testing
Date: 3/17/25
Revision: 1
Reason: Per client request, sodium, potassium and magnesium were added.
3249 Fitzgerald Road, Rancho Cordova, CA 95742 | 800.638.7301 | Tel: 916.638.7301 x102 | Fax: 916.638.4510 | www.californialab.com
Small Business #2916 | ELAP #1233 | NAICS #541380 | CA SWRCB ELAP Accreditation/Registration Number 1233
Revision History
Client: Hyperion Biotechnology Work Order: 25C0187 Project Name: Martinez Specialized Testing
Date: 3/18/25
Revision: 2
Reason: At the client's request, calcium has been included in the work order.
Project:
Project Number:
Project Manager:
Hyperion Biotechnology
12002 Warfield St. Suite 101
03/18/25 08:45
San Antonio, TX 78216
CLS Work Order #: 25C0187
COC #:
Conventional Chemistry Parameters by APHA/EPA Methods
Result Analyte Limit
Reporting
Units Dilution Batch Prepared Analyzed Method Notes
Patient room # N123 (25C0187-01) Water Sampled: 03/05/25 11:16 Received: 03/05/25 15:30
2501905 03/06/25 mg/L 1Fluoride 0.66 0.10 EPA 300.003/06/25
""" ""Nitrate as N ND 0.40 "
2501928 03/06/25 µmhos/cm "Specific Conductance (EC) 320 1.0 SM 2510
B-1997 03/06/25
2501905 03/10/25 mg/L 2Sulfate as SO4 40 1.0 EPA 300.003/06/25
2501909 03/10/25 " 1Total Hardness as CaCO3 78 1.0 EPA 200.703/06/25
Sterilization room equip wall port (25C0187-02) Water Sampled: 03/05/25 11:20 Received: 03/05/25 15:30
2501905 03/06/25 mg/L 1Fluoride 0.66 0.10 EPA 300.003/06/25
""" ""Nitrate as N ND 0.40 "
2501928 03/06/25 µmhos/cm "Specific Conductance (EC) 280 1.0 SM 2510
B-1997 03/06/25
2501905 03/06/25 mg/L "Sulfate as SO4 36 0.50 EPA 300.003/06/25
2501909 03/10/25 " "Total Hardness as CaCO3 68 1.0 EPA 200.703/06/25
3249 Fitzgerald Road, Rancho Cordova, CA 95742 | 800.638.7301 | Tel: 916.638.7301 x102 | Fax: 916.638.4510 | www.californialab.com
Small Business #2916 | ELAP #1233 | NAICS #541380 | CA SWRCB ELAP Accreditation/Registration Number 1233 For regulatory purposes, please refer to www.californialab.com/certifications to find a list of approved analytes by method.
Martinez Specialized Testing [none]
Alicia Richarte
Project Manager:
Hyperion Biotechnology
12002 Warfield St. Suite 101
03/18/25 08:45
San Antonio, TX 78216
CLS Work Order #: 25C0187
COC #:
Metals by EPA 200 Series Methods
Result Analyte Limit
Reporting
Units Dilution Batch Prepared Analyzed Method Notes
Patient room # N123 (25C0187-01) Water Sampled: 03/05/25 11:16 Received: 03/05/25 15:30
2501909 03/17/25 µg/L 1Calcium 15000 1000 EPA 200.703/06/25
" 03/07/25 " "Magnesium 8200 1000 ""
" 03/06/25 " "Potassium 1900 1000 ""
" 03/07/25 " "Sodium 33000 1000 ""
Sterilization room equip wall port (25C0187-02) Water Sampled: 03/05/25 11:20 Received: 03/05/25 15:30
2501909 03/17/25 µg/L 1Calcium 13000 1000 EPA 200.703/06/25
" 03/07/25 " "Magnesium 7300 1000 ""
" 03/06/25 " "Potassium 1700 1000 ""
" 03/07/25 " "Sodium 30000 1000 ""
3249 Fitzgerald Road, Rancho Cordova, CA 95742 | 800.638.7301 | Tel: 916.638.7301 x102 | Fax: 916.638.4510 | www.californialab.com
Small Business #2916 | ELAP #1233 | NAICS #541380 | CA SWRCB ELAP Accreditation/Registration Number 1233 For regulatory purposes, please refer to www.californialab.com/certifications to find a list of approved analytes by method.
Martinez Specialized Testing
Project Manager:
Hyperion Biotechnology
12002 Warfield St. Suite 101
03/18/25 08:45
San Antonio, TX 78216
CLS Work Order #: 25C0187
COC #:
Metals (Drinking Water) by EPA 200 Series Methods
Result Analyte Limit
Reporting
Units Dilution Batch Prepared Analyzed Method Notes
Patient room # N123 (25C0187-01) Water Sampled: 03/05/25 11:16 Received: 03/05/25 15:30
EPA 200.803/06/25 µg/L 25019101Aluminum ND 50 03/06/25
"03/07/25 " ""Antimony ND 4.0 "
"03/06/25 " ""Arsenic ND 2.0 "
""" ""Barium ND 100 "
""" ""Beryllium ND 1.0 "
""" ""Cadmium ND 1.0 "
""" ""Chromium ND 10 "
" "" "Copper 340 50 ""
""" ""Lead ND 5.0 "
EPA 245.103/10/25 " 2501975"Mercury ND 1.0 03/07/25
EPA 200.803/06/25 " 2501910"Nickel ND 10 03/06/25
""" ""Selenium ND 5.0 "
""" ""Silver ND 10 "
""" ""Thallium ND 1.0 "
" "" "Zinc 61 50 ""
Sterilization room equip wall port (25C0187-02) Water Sampled: 03/05/25 11:20 Received: 03/05/25 15:30
EPA 200.803/06/25 µg/L 25019101Aluminum ND 50 03/06/25
"03/07/25 " ""Antimony ND 4.0 "
"03/06/25 " ""Arsenic ND 2.0 "
""" ""Barium ND 100 "
""" ""Beryllium ND 1.0 "
""" ""Cadmium ND 1.0 "
""" ""Chromium ND 10 "
" "" "Copper 72 50 ""
""" ""Lead ND 5.0 "
EPA 245.103/10/25 " 2501975"Mercury ND 1.0 03/07/25
EPA 200.803/06/25 " 2501910"Nickel ND 10 03/06/25
""" ""Selenium ND 5.0 "
""" ""Silver ND 10 "
""" ""Thallium ND 1.0 "
3249 Fitzgerald Road, Rancho Cordova, CA 95742 | 800.638.7301 | Tel: 916.638.7301 x102 | Fax: 916.638.4510 | www.californialab.com
Small Business #2916 | ELAP #1233 | NAICS #541380 | CA SWRCB ELAP Accreditation/Registration Number 1233 For regulatory purposes, please refer to www.californialab.com/certifications to find a list of approved analytes by method.
Martinez Specialized Testing
Project Manager:
Hyperion Biotechnology
12002 Warfield St. Suite 101
03/18/25 08:45
San Antonio, TX 78216
CLS Work Order #: 25C0187
COC #:
Metals (Drinking Water) by EPA 200 Series Methods
Result Analyte Limit
Reporting
Units Dilution Batch Prepared Analyzed Method Notes
Sterilization room equip wall port (25C0187-02) Water Sampled: 03/05/25 11:20 Received: 03/05/25 15:30
EPA 200.803/06/25 µg/L 25019101Zinc ND 50 "
3249 Fitzgerald Road, Rancho Cordova, CA 95742 | 800.638.7301 | Tel: 916.638.7301 x102 | Fax: 916.638.4510 | www.californialab.com
Small Business #2916 | ELAP #1233 | NAICS #541380 | CA SWRCB ELAP Accreditation/Registration Number 1233 For regulatory purposes, please refer to www.californialab.com/certifications to find a list of approved analytes by method.
Martinez Specialized Testing
Project Manager:
Hyperion Biotechnology
12002 Warfield St. Suite 101
03/18/25 08:45
San Antonio, TX 78216
CLS Work Order #: 25C0187
COC #:
Microbiological Parameters by APHA Standard Methods
Result Analyte Limit
Reporting
Units Dilution Batch Prepared Analyzed Method Notes
Patient room # N123 (25C0187-01) Water Sampled: 03/05/25 11:16 Received: 03/05/25 15:30
SM 9215B03/07/25 CFU/mL 25019381Plate Count <1 1 03/05/25
Sterilization room equip wall port (25C0187-02) Water Sampled: 03/05/25 11:20 Received: 03/05/25 15:30
2501938 03/07/25 CFU/mL 1Plate Count 53 1 SM 9215B03/05/25
3249 Fitzgerald Road, Rancho Cordova, CA 95742 | 800.638.7301 | Tel: 916.638.7301 x102 | Fax: 916.638.4510 | www.californialab.com
Small Business #2916 | ELAP #1233 | NAICS #541380 | CA SWRCB ELAP Accreditation/Registration Number 1233 For regulatory purposes, please refer to www.californialab.com/certifications to find a list of approved analytes by method.
Martinez Specialized Testing
Project Manager:
Hyperion Biotechnology
12002 Warfield St. Suite 101
03/18/25 08:45
San Antonio, TX 78216
CLS Work Order #: 25C0187
COC #:
Result Limit
Reporting
Units Level
Spike
Result
Source
%REC
%REC
Limits RPD
RPD
Limit Notes Analyte
Conventional Chemistry Parameters by APHA/EPA Methods - Quality Control
Batch 2501905 - General Prep
Blank (2501905-BLK1) Prepared & Analyzed: 03/06/25
Sulfate as SO4 mg/LND 0.50
Fluoride "ND 0.10
Nitrate as N "ND 0.40
LCS (2501905-BS1) Prepared & Analyzed: 03/06/25
Sulfate as SO4 mg/L4.85 0.50 5.00 80-12097
Fluoride "1.97 0.10 2.00 80-12098
Nitrate as N "1.84 0.40 2.00 80-12092
LCS Dup (2501905-BSD1) Prepared & Analyzed: 03/06/25
Sulfate as SO4 mg/L4.88 0.50 5.00 2080-12098 0.5
Fluoride "2.03 0.10 2.00 2080-120102 3
Nitrate as N "1.85 0.40 2.00 2080-12093 0.6
Matrix Spike (2501905-MS1) Prepared & Analyzed: 03/06/25 Source: 25C0188-01
Sulfate as SO4 mg/L31.3 0.50 5.00 27.2 80-12082
Fluoride "2.92 0.10 2.00 1.08 80-12092
Nitrate as N "5.79 0.40 2.00 3.98 80-12090
Matrix Spike Dup (2501905-MSD1) Prepared & Analyzed: 03/06/25 Source: 25C0188-01
Sulfate as SO4 mg/L31.4 0.50 5.00 27.2 2080-12084 0.2
Fluoride "2.95 0.10 2.00 1.08 2080-12094 0.9
Nitrate as N "5.80 0.40 2.00 3.98 2080-12091 0.2
Batch 2501909 - EPA 200 Series
Blank (2501909-BLK1) Prepared: 03/06/25 Analyzed: 03/11/25
Total Hardness as CaCO3 mg/LND 1.0
3249 Fitzgerald Road, Rancho Cordova, CA 95742 | 800.638.7301 | Tel: 916.638.7301 x102 | Fax: 916.638.4510 | www.californialab.com
Small Business #2916 | ELAP #1233 | NAICS #541380 | CA SWRCB ELAP Accreditation/Registration Number 1233 For regulatory purposes, please refer to www.californialab.com/certifications to find a list of approved analytes by method.
Martinez Specialized Testing
Project Manager:
Hyperion Biotechnology
12002 Warfield St. Suite 101
03/18/25 08:45
San Antonio, TX 78216
CLS Work Order #: 25C0187
COC #:
Result Limit
Reporting
Units Level
Spike
Result
Source
%REC
%REC
Limits RPD
RPD
Limit Notes Analyte
Conventional Chemistry Parameters by APHA/EPA Methods - Quality Control
Batch 2501909 - EPA 200 Series
LCS (2501909-BS1) Prepared: 03/06/25 Analyzed: 03/11/25
Total Hardness as CaCO3 mg/L35.2 1.0 33.1 85-115106
Matrix Spike (2501909-MS1) Prepared: 03/06/25 Analyzed: 03/11/25 Source: 25C0084-03
Total Hardness as CaCO3 mg/L322 1.0 33.1 279 70-130129
Matrix Spike (2501909-MS2) Prepared: 03/06/25 Analyzed: 03/11/25 Source: 25C0192-01
Total Hardness as CaCO3 mg/L208 1.0 33.1 175 70-13099
Batch 2501928 - General Preparation
Blank (2501928-BLK1) Prepared & Analyzed: 03/06/25
Specific Conductance (EC) µmhos/cmND 1.0
Duplicate (2501928-DUP1) Prepared & Analyzed: 03/06/25 Source: 25C0261-01
Specific Conductance (EC) µmhos/cm736 1.0 724 201.64
3249 Fitzgerald Road, Rancho Cordova, CA 95742 | 800.638.7301 | Tel: 916.638.7301 x102 | Fax: 916.638.4510 | www.californialab.com
Small Business #2916 | ELAP #1233 | NAICS #541380 | CA SWRCB ELAP Accreditation/Registration Number 1233 For regulatory purposes, please refer to www.californialab.com/certifications to find a list of approved analytes by method.
Martinez Specialized Testing
Project Manager:
Hyperion Biotechnology
12002 Warfield St. Suite 101
03/18/25 08:45
San Antonio, TX 78216
CLS Work Order #: 25C0187
COC #:
Result Limit
Reporting
Units Level
Spike
Result
Source
%REC
%REC
Limits RPD
RPD
Limit Notes Analyte
Metals by EPA 200 Series Methods - Quality Control
Batch 2501909 - EPA 200 Series
Blank (2501909-BLK1) Prepared & Analyzed: 03/06/25
Calcium µg/LND 1000
Magnesium "ND 1000
Potassium "ND 1000
Sodium "ND 1000
LCS (2501909-BS1) Prepared & Analyzed: 03/06/25
Calcium µg/L5290 1000 5000 85-115106
Magnesium "5490 1000 5000 85-115110
Potassium "5210 1000 5000 85-115104
Sodium "5690 1000 5000 85-115114
Matrix Spike (2501909-MS1) Prepared & Analyzed: 03/06/25 Source: 25C0084-03
Calcium µg/L47400 1000 5000 45700 QM-770-13033
Potassium "37000 1000 5000 34200 QM-770-13055
Sodium "172000 1000 5000 180000 QM-770-130NR
Matrix Spike (2501909-MS2) Prepared & Analyzed: 03/06/25 Source: 25C0192-01
Calcium µg/L39000 1000 5000 33800 70-130105
Magnesium "23600 1000 5000 19400 70-13083
Potassium "6990 1000 5000 1580 70-130108
Sodium "28400 1000 5000 24400 70-13081
3249 Fitzgerald Road, Rancho Cordova, CA 95742 | 800.638.7301 | Tel: 916.638.7301 x102 | Fax: 916.638.4510 | www.californialab.com
Small Business #2916 | ELAP #1233 | NAICS #541380 | CA SWRCB ELAP Accreditation/Registration Number 1233 For regulatory purposes, please refer to www.californialab.com/certifications to find a list of approved analytes by method.
Martinez Specialized Testing
Project Manager:
Hyperion Biotechnology
12002 Warfield St. Suite 101
Martinez Specialized Testing [none]
Alicia Richarte
03/18/25 08:45
San Antonio, TX 78216
CLS Work Order #: 25C0187
COC #:
Result Limit
Reporting
Units Level
Spike
Result
Source
%REC
%REC
Limits RPD
RPD
Limit Notes Analyte
Metals (Drinking Water) by EPA 200 Series Methods - Quality Control
Batch 2501910 - EPA 200 Series
Blank (2501910-BLK1) Prepared & Analyzed: 03/06/25
Aluminum µg/LND 50
Antimony "ND 4.0
Arsenic "ND 2.0
Barium "ND 100
Beryllium "ND 1.0
Cadmium "ND 1.0
Chromium "ND 10
Copper "ND 50
Lead "ND 5.0
Nickel "ND 10
Selenium "ND 5.0
Silver "ND 10
Thallium "ND 1.0
Zinc "ND 50
LCS (2501910-BS1) Prepared & Analyzed: 03/06/25
Aluminum µg/L564 50 500 85-115113
Antimony "119 4.0 100 QM-185-115119
Arsenic "109 2.0 100 85-115109
Barium "111 100 100 85-115111
Beryllium "109 1.0 100 85-115109
Cadmium "112 1.0 100 85-115112
Chromium "111 10 100 85-115111
Copper "113 50 100 85-115113
Lead "112 5.0 100 85-115112
Nickel "114 10 100 85-115114
Selenium "110 5.0 100 85-115110
Silver "114 10 100 85-115114
Thallium "110 1.0 100 85-115110
Zinc "111 50 100 85-115111
3249 Fitzgerald Road, Rancho Cordova, CA 95742 | 800.638.7301 | Tel: 916.638.7301 x102 | Fax: 916.638.4510 | www.californialab.com
Small Business #2916 | ELAP #1233 | NAICS #541380 | CA SWRCB ELAP Accreditation/Registration Number 1233 For regulatory purposes, please refer to www.californialab.com/certifications to find a list of approved analytes by method.
Project Manager:
Hyperion Biotechnology
12002 Warfield St. Suite 101
Martinez Specialized Testing [none]
Alicia Richarte
03/18/25 08:45
San Antonio, TX 78216
CLS Work Order #: 25C0187
COC #:
Result Limit
Reporting
Units Level
Spike
Result
Source
%REC
%REC
Limits RPD
RPD
Limit Notes Analyte
Metals (Drinking Water) by EPA 200 Series Methods - Quality Control
Batch 2501910 - EPA 200 Series
Matrix Spike (2501910-MS1) Prepared & Analyzed: 03/06/25 Source: 25C0163-01
Aluminum µg/L772 50 500 264 70-130102
Antimony "116 4.0 100 3.83 70-130112
Arsenic "127 2.0 100 21.6 70-130105
Barium "202 100 100 91.8 70-130110
Beryllium "109 1.0 100 ND 70-130109
Cadmium "108 1.0 100 0.462 70-130108
Chromium "108 10 100 2.09 70-130106
Copper "146 50 100 41.4 70-130105
Lead "135 5.0 100 24.4 70-130111
Nickel "115 10 100 4.04 70-130111
Selenium "92.0 5.0 100 2.24 70-13090
Silver "111 10 100 ND 70-130111
Thallium "108 1.0 100 0.121 70-130108
Zinc "733 50 100 634 70-13099
Matrix Spike (2501910-MS2) Prepared & Analyzed: 03/06/25 Source: 25C0163-06
Aluminum µg/L586 50 500 52.8 70-130107
Antimony "117 4.0 100 1.85 70-130116
Arsenic "106 2.0 100 1.94 70-130104
Barium "183 100 100 73.6 70-130110
Beryllium "110 1.0 100 ND 70-130110
Cadmium "106 1.0 100 ND 70-130106
Chromium "108 10 100 4.14 70-130104
Copper "171 50 100 66.6 70-130105
Lead "119 5.0 100 10.8 70-130108
Nickel "111 10 100 5.41 70-130105
Selenium "106 5.0 100 2.77 70-130103
Silver "108 10 100 ND 70-130108
Thallium "105 1.0 100 ND 70-130105
Zinc "184 50 100 77.9 70-130106
3249 Fitzgerald Road, Rancho Cordova, CA 95742 | 800.638.7301 | Tel: 916.638.7301 x102 | Fax: 916.638.4510 | www.californialab.com
Small Business #2916 | ELAP #1233 | NAICS #541380 | CA SWRCB ELAP Accreditation/Registration Number 1233 For regulatory purposes, please refer to www.californialab.com/certifications to find a list of approved analytes by method.
Project Manager:
Hyperion Biotechnology
12002 Warfield St. Suite 101
Martinez Specialized Testing [none] Alicia Richarte
03/18/25 08:45
San Antonio, TX 78216
CLS Work Order #: 25C0187
COC #:
Result Limit
Reporting
Units Level
Spike
Result
Source
%REC
%REC
Limits RPD
RPD
Limit Notes Analyte
Metals (Drinking Water) by EPA 200 Series Methods - Quality Control
Batch 2501975 - EPA 7470A
Blank (2501975-BLK1) Prepared: 03/07/25 Analyzed: 03/10/25
Mercury µg/LND 1.0
LCS (2501975-BS1) Prepared: 03/07/25 Analyzed: 03/10/25
Mercury µg/L5.04 1.0 5.00 85-115101
Matrix Spike (2501975-MS1) Prepared: 03/07/25 Analyzed: 03/10/25 Source: 25C0086-01
Mercury µg/L5.01 1.0 5.00 ND 70-130100
Matrix Spike (2501975-MS2) Prepared: 03/07/25 Analyzed: 03/10/25 Source: 25C0285-01
Mercury µg/L4.61 1.0 5.00 ND 70-13092
Matrix Spike Dup (2501975-MSD1) Prepared: 03/07/25 Analyzed: 03/10/25 Source: 25C0086-01
Mercury µg/L4.95 1.0 5.00 ND 2570-13099 1
3249 Fitzgerald Road, Rancho Cordova, CA 95742 | 800.638.7301 | Tel: 916.638.7301 x102 | Fax: 916.638.4510 | www.californialab.com
Small Business #2916 | ELAP #1233 | NAICS #541380 | CA SWRCB ELAP Accreditation/Registration Number 1233 For regulatory purposes, please refer to www.californialab.com/certifications to find a list of approved analytes by method.
Project Manager:
Hyperion Biotechnology
12002 Warfield St. Suite 101
Martinez Specialized Testing [none]
Alicia Richarte
03/18/25 08:45
San Antonio, TX 78216
CLS Work Order #: 25C0187
COC #:
Notes and Definitions
QM-7 The spike recovery was outside acceptance limits for the MS and/or MSD. The batch was accepted based on acceptable LCS and/or LCSD recovery.
QM-1 The spike recovery was outside acceptance limits for the LCS or LCSD. The batch was accepted based on acceptable MS/MSD recoveries & RPD's.
BT-4 <1
Sample results reported on a dry weight basis
Relative Percent DifferenceRPD dry
Not ReportedNR
Analyte NOT DETECTED at or above the reporting limit (or method detection limit when specified)ND
Analyte DETECTEDDET
3249 Fitzgerald Road, Rancho Cordova, CA 95742 | 800.638.7301 | Tel: 916.638.7301 x102 | Fax: 916.638.4510 | www.californialab.com
Small Business #2916 | ELAP #1233 | NAICS #541380 | CA SWRCB ELAP Accreditation/Registration Number 1233 For regulatory purposes, please refer to www.californialab.com/certifications to find a list of approved analytes by method.
| SECTION 22 67 19.16 |
| REVERSE-OSMOSIS WATER EQUIPMENT |
File details come from the government source that posted it. Updated .