Construction Documentation Summary

This file is a comprehensive set of construction documentation prepared by Catalyst Design Group (landscape architect) and Carter Kaye (civil engineer) for the City of Bartow's Polk Street Community Center renovation project located at 1255 Polk Street, Bartow, Florida 33830. The project scope encompasses parking lot improvements and landscape renovation including removal of existing trees, parking surface repairs or replacement, and installation of new plantings with emphasis on low-maintenance, durable species appropriate for high-use public facilities. The documentation includes landscape plans and specifications covering 20 canopy trees (consisting of 1 Florida Flame Red Maple, 3 D.D. Blanchard Southern Magnolias, and 2 Southern Live Oaks), 20 understory Crape Myrtles, 168 Podocarpus shrubs, 232 Pink Muhly Grass plants, 718 Blue My Mind Dwarf Morning Glory groundcovers, 280 Emerald Goddess Lilyturf plants, 1,889 Minima Jasmine plants, 214 Variegated Lilyturf plants, and 4,023 square feet of Argentine Bahia Grass sod. All plantings are scheduled with 3 inches of Melaleuca mulch top-dressing and must comply with Florida Department of Agriculture and Consumer Services No. 1 Grade standards. The documentation is dated June 18, 2026, and represents 100% construction documentation.

The specifications require contractors to provide hand watering in all planting areas regardless of irrigation system status, replace any plant material damaged during installation, prepare approved planting soil mixtures meeting specified ratios, and maintain plants through a one-year guarantee period following substantial completion. An automatic irrigation system with rain sensor is required, incorporating eight valve stations with varying gallonages ranging from 11.2 to 26.3 GPM and utilizing Hunter-brand controllers, sprinklers, and drip irrigation components. Contractors must submit a written survivability guarantee for all plant material for one year from the date of substantial completion and notify the owner's representative at least seven days prior to the anticipated substantial completion inspection. Contractors bear responsibility for all soil testing costs, verification of plant quantities prior to contract award, obtaining all necessary permits, and compliance with applicable jurisdictional codes. The project includes detailed specifications for tree staking using lodge poles, shrub and groundcover installation with triangular spacing, sodding procedures, and comprehensive irrigation system installation meeting Florida Water Star requirements and local watering restrictions.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT LOCATION

1085 W MORSE BLVD, WINTER PARK, FL 32789

(615) 622-7200 | WWW.CATALYST-DG.COM

LANDSCAPE ARCHITECT

Florida Firm Registration No. 33093

VICINITY MAP

NOT TO SCALE

C0.0

COVER SHEET

100% Construction Documentation

POLK STREET COMMUNITY CENTER

BARTOW, FLORIDA

CATALYST PROJECT NO. 20260026

June 18, 2026

CLIENTCIVIL ENGINEER

THIS ITEM HAS BEEN ELECTRONICALLY

SIGNED AND SEALED BY EOR NAME, PE USING

A DIGITAL SIGNATURE AND DATE. PRINTED

COPIES OF THIS DOCUMENT ARE NOT

CONSIDERED SIGNED AND SEALED AND THE

SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

2250 S. FLORAL AVE., BARTOW, FL 33830

863-534-0120 | PARKS.INFO@CITYOFBARTOW.NET

137 5TH STREET NW, WINTER HAVEN, FL 33881

(863) 294-6965 | WWW.CARTERKAYE.COM

Sheet List Table Sheet Number Sheet Title

C0.0 Cover Sheet L1.00 Landscape Notes & Symbols L2.00 Landscape Plan L2.01 Landscape Schedule L3.00 Landscape Details L3.10 Landscape Specifications L3.11 Landscape Specifications L6.00 Irrigation Plan L7.00 Irrigation Notes L7.10 Irrigation Details L7.11 Irrigation Details L7.12 Irrigation Details L7.13 Irrigation Details

P:

\2

6\

_C ity o f B ar to w

Po lk

S tre et C om m un ity

C en te r\ dw g\

Co ns tru ct io n\

_L 2-

0_

LA

N.

dw g- La nd sc ap e

No te s

Sy m bo ls

Ju n

, 2 ww an g

DRAWING NUMBER

PROJECT NUMBER

DRAWING TITLE

DE

SC

RI

PT

IO

N

DA

TE

NO

6/

/2

C D

W

M O

R S E

B

LV

D

W

IN

TE

R P

A R K

FL

(6

9-

W W

W .C

A

TA

LY

S T-

D G

.C O

M

FI

R S T

LA

S T, P E

X X X X X

FI

R S T

LA

S T, P

LA

L A X

X X X X

Fl or id a

Fi rm

R eg is tr at io n N o.

20260026

PO

LK

S

TR

EE

T

CO

MM

UN

IT

Y

CE

NT

ER

P

OL

K

ST

RE

ET

BA

RT

OW

, F

LO

RI

DA

, 3

0%

C

ON

ST

RU

CT

IO

N

DO

CU

ME

NT

AT

IO

N

L1.00

Know what's below.

Call before you dig.

LANDSCAPE NOTES

& SYMBOLS

LANDSCAPE NOTES

1. CONTRACTOR SHALL BE RESPONSIBLE FOR HAND WATERING IN ALL PLANTING AREAS, REGARDLESS OF THE STATUS OF EXISTING OR PROPOSED IRRIGATION.

2. CONTRACTOR SHALL RE-GRADE ALL AREAS DISTURBED BY PLANT REMOVAL, RELOCATION, AND/OR INSTALLATION WORK.

3. CONTRACTOR SHALL REPLACE (BY EQUAL SIZE AND QUALITY) ANY AND ALL EXISTING PLANT MATERIAL/SOD DISTURBED OR DAMAGED BY PLANT REMOVAL, RELOCATION, AND/OR INSTALLATION WORK.

4. THE CONTRACTOR SHALL PROVIDE AN APPROVED PLANTING SOIL MIXTURE FOR ALL PLANT MATERIAL. SEE SPECIFICATIONS FOR REQUIREMENTS.

5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR STABILITY AND PLUMB CONDITION OF ALL TREES AND SHRUBS, AND SHALL BE LEGALLY LIABLE FOR ANY DAMAGE CAUSED BY INSTABILITY OF ANY PLANT MATERIALS. STAKING OF TREES OR SHRUBS SHALL BE DONE IN ACCORDANCE WITH PLANS AND SPECIFICATIONS.

6. THE CONTRACTOR SHALL INSURE ADEQUATE VERTICAL DRAINAGE IN ALL PLANT BEDS AND PLANTERS. IF INADEQUATE VERTICAL DRAINAGE IS ENCOUNTERED, THE CONTRACTOR SHALL SUBMIT RECOMMENDATIONS FOR PROVIDING ADEQUATE DRAINAGE TO THE OWNER'S REPRESENTATIVE.

7. CONTRACTOR SHALL FIELD-ADJUST LOCATION OF PLANT MATERIAL PRIOR TO INITIATING INSTALLATION FOR THE REVIEW AND APPROVAL OF THE OWNER'S

REPRESENTATIVE.

8. UPON COMPLETION OF ALL LANDSCAPING, AN INSPECTION FOR SUBSTANTIAL COMPLETION OF THE WORK SHALL BE HELD. THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE FOR SCHEDULING THE INSPECTION AT LEAST SEVEN (7) DAYS PRIOR TO THE ANTICIPATED INSPECTION DATE.

9. CONTRACTOR SHALL SUBMIT WRITTEN GUARANTEE OF SURVIVABILITY OF ALL PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION.

10. CONTRACTOR MUST REVIEW AND ACCEPT, APPROVE ALL GRADED AREAS PRIOR TO THE COMMENCEMENT OF PLANTING.

11. TREES ADJACENT TO BUILDINGS SHOULD BE PLANTED AT LEAST THE DIAMETER OF THE TREE CANOPY OR A MIN. OF 10'-0" (WHICHEVER IS GREATER) AWAY FROM THE

BUILDING WALL.

12. MAINTENANCE SHALL BEGIN AFTER EACH PLANT HAS BEEN INSTALLED AND SHALL CONTINUE UNTIL THE PROJECT HAS BEEN DEEMED SUBSTANTIALLY COMPLETE.

MAINTENANCE INCLUDES WATERING, PRUNING, WEEDING, MULCHING, REPLACEMENTS OF SICK OR DEAD PLANTS, AND ANY OTHER CARE NECESSARY FOR THE PROPER

GROWTH OF THE PLANT MATERIAL.

13. ALL PLANT MATERIAL SHALL BE IN FULL AND STRICT ACCORDANCE WITH FLORIDA NO. 1 GRADE OR BETTER, ACCORDING TO THE "GRADES AND STANDARDS FOR NURSERY PLANTS" PUBLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES.

14. ALL PLANTING BEDS SHALL BE TOP-DRESSED WITH A 3" LAYER OF MULCH AS SPECIFIED.

15. CONTRACTOR SHALL COORDINATE ALL PLANTING WORK WITH IRRIGATION WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HAND WATERING AS REQUIRED TO

SUPPLEMENT IRRIGATION WATERING AND RAINFALL.

16. THE CONTRACTOR SHALL REVIEW PLANS TO BECOME THOROUGHLY FAMILIAR WITH SURFACE AND SUBSURFACE UTILITIES.

17. THE PLANT QUANTITIES SHOWN ON THE LANDSCAPE CONTRACT DOCUMENTS ARE FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL QUANTITIES AND REPORTING ANY DISCREPANCIES TO THE LANDSCAPE ARCHITECT FOR CLARIFICATION PRIOR TO CONTRACT AWARD AND

COMMENCEMENT OF WORK.

18. PEG SOD ON SLOPES GREATER THAN 3:1.

19. CONTRACTOR SHALL PROTECT EXISTING VEGETATION TO REMAIN AS SHOWN ON DRAWINGS OR BY MEANS APPROVED BY THE OWNER'S REPRESENTATIVE.

20. CONTRACTOR TO CLEAN, PRUNE, AND SHAPE EDGES OF EXISTING VEGETATION AS DIRECTED BY OWNER'S REPRESENTATIVE. CREATE SMOOTH BED LINES AROUND

EXISTING VEGETATION.

21. THE CONTRACTOR SHALL BEAR ALL COSTS OF TESTING OF SOILS, AMENDMENTS, ETC. ASSOCIATED WITH THE WORK. SEE SPECIFICATIONS FOR ADDITIONAL TESTING

REQUIREMENTS.

22. ALL INSTALLATION OF PLANT MATERIAL SHALL COMPLY WITH APPLICABLE JURISDICTIONAL CODES. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS

ASSOCIATED WITH THIS WORK.

23. PRIOR TO PLANTING INSTALLATION, THE CONTRACTOR SHALL CONFIRM THE AVAILABILITY OF ALL THE SPECIFIED PLANT MATERIALS. SUBMIT DATED PHOTOGRAPHS OF ALL TREE MATERIAL AND SPECIMEN MATERIAL AS TO THE OWNER'S REPRESENTATIVE FOR REVIEW.

24. ALL PLANT MATERIAL SIZES SPECIFIED ARE MINIMUM SIZES. CONTAINER SIZE SHALL BE INCREASED IF NECESSARY TO PROVIDE OVERALL PLANT SIZE SPECIFIED.

25. IF PLANT MATERIAL DOES NOT COMPLY WITH THE REQUIREMENTS AS SPECIFIED HEREIN, THE OWNER'S REPRESENTATIVE RESERVES THE RIGHT TO REJECT SUCH PLANTS AND REQUIRE THE CONTRACTOR TO REPLACE REJECTED WORK AND CONTINUE SPECIFIED MAINTENANCE UNTIL RE-INSPECTED AND FOUND TO BE

ACCEPTABLE.

ALN Align CJ Control Joint CL Centerline EJ Expansion Joint EQ Equal Dimension FFE Finish Floor Elevation FOB Face of Building FOW Face of Wall MAX Maximum MIN Minimum PA Planting Area POB Point of Beginning PT Point of Tangency R Radius REF Reference Line TOW Top of Wall TYP Typical QTY Quantity SOG Slab on Grade

CONSTRUCTION ABBREVIATIONS

H1.20

H1.20

H1.20

H1.20

H1.20

STANDARD DRAWING SYMBOLS

ELEVATION DETAIL REFERENCE

Detail Number Sheet Number

SECTION DETAIL REFERENCE

Detail Number Sheet Number

GENERAL DETAIL REFERENCE

Detail Number Sheet Number

PLAN ENLARGEMENT REFERENCE

Detail Number Sheet Number

DETAIL ENLARGEMENT REFERENCE

Detail Number Sheet Number

MATCHLINE

FINISH REFERENCE

See Finish Schedule

MATCHLINE:

REVISIONS

Revision Area Revision Number

FINISH ITEMSF1

GENERAL NOTES

1. THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE PROJECT SITE PRIOR TO BIDDING THE WORK. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND LOCATION OF PROPOSED IMPROVEMENTS PRIOR TO INITIATING ANY CONSTRUCTION.

2. LOCATION OF ALL UTILITIES AND BASE INFORMATION IS APPROXIMATE. CONTRACTOR SHALL VERIFY ALL UNDERGROUND UTILITIES AND OBSTRUCTIONS PRIOR TO INITIATING WORK.

CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OR REPLACEMENT OF ANY DAMAGE TO EXISTING ELEMENTS ABOVE OR BELOW GROUND TO ITS ORIGINAL CONDITION AND TO

THE SATISFACTION OF THE OWNER'S REPRESENTATIVE.

3. THE OWNER'S REPRESENTATIVE SHALL HAVE THE RIGHT, AT ANY STAGE OF THE OPERATIONS, TO REJECT ANY AND ALL WORK AND MATERIAL WHICH, IN HIS OPINION, DO NOT MEET

WITH THE REQUIREMENTS OF THESE PLANS AND SPECIFICATIONS.

4. CONTRACTOR SHALL VERIFY ALL GRADES, DIMENSIONS, AND EXISTING CONDITIONS ON THE JOB SITE PRIOR TO START OF CONSTRUCTION AND/OR FABRICATION. CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THESE DRAWINGS.

5. REPORT ANY DISCREPANCIES BETWEEN THE CONSTRUCTION DRAWINGS AND FIELD CONDITIONS TO THE OWNER'S REPRESENTATIVE.

6. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY SAFETY MEASURES DURING CONSTRUCTION OPERATIONS TO PROTECT THE PUBLIC ACCORDING TO ALL APPLICABLE CODES

AND RECOGNIZED LOCAL PRACTICES.

7. THE CONTRACTOR SHALL COORDINATE ACCESS AND STAGING AREAS WITH THE OWNER'S REPRESENTATIVE. THE CONTRACTOR SHALL MAINTAIN ALL EXISTING EROSION AND SEDIMENTATION CONTROL MEASURES DURING CONSTRUCTION. PROVIDE ADDITIONAL MEASURES AS NECESSARY TO MINIMIZE ADVERSE IMPACTS IN ACCORDANCE WITH ALL

APPLICABLE FEDERAL, STATE, AND LOCAL CODES.

8. NO SUBSTITUTIONS SHALL BE MADE WITHOUT WRITTEN CONSENT OF THE OWNER'S REPRESENTATIVE. DURING THE COURSE OF THIS WORK, EXCESS WASTE MATERIAL SHALL BE

REMOVED DAILY FROM THE SITE.

9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATION OF WORK WITH OTHER TRADES AND THE OWNER'S REPRESENTATIVE.

10. THE CONTRACTOR SHALL NOTIFY ALL NECESSARY UTILITY COMPANIES 48 HRS MINIMUM PRIOR TO DIGGING FOR FIELD VERIFICATION OF ALL UNDERGROUND UTILITIES. UTILITY LOCATING SHALL BE SCHEDULED BY THE CONTRACTOR WITH OWNER'S REPRESENTATIVE PRESENT.

11. UTILITIES TO BE LOCATED BY FLAGGING ONLY; PAINTING OF HARDSCAPE AREAS IS PROHIBITED. CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING UTILITY LOCATING

COMPANIES OF THIS REQUIREMENT.

12. ALL EXISTING SITE ROADS, PARKING LOTS, CURBS, UTILITIES, SEWERS, AND OTHER ELEMENTS TO REMAIN SHALL BE FULLY PROTECTED FROM ANY DAMAGE UNLESS OTHERWISE

NOTED.

13. NOT ALL ITEMS SHOWN ON THIS SHEET APPEAR IN THE CONSTRUCTION DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS RELATED TO CONSTRUCTION INCLUDING, BUT NOT LIMITED TO: BUILDING, LANDSCAPE, IRRIGATION AND RIGHT-OF-WAY UTILIZATION PERMITS.

AutoCAD SHX Text

SYMBOL CODE COMMON NAME

CANOPY TREES

MB D.D Blanchard Southern Magnolia

AF Florida Flame Red Maple

QV Southern Live Oak

UNDERSTORY TREES

LIN Crape Myrtle

SHRUBS

PP Podocarpus

SHRUB AREAS

MCA Pink Muhly Grass

GROUND COVERS

EG Blue My Mind Dwarf Morning Glory

LE Emerald Goddess Lilyturf

TM Minima Jasmine

AG Perennial Peanut

LEV Varigated Lilyturf

SOD/SEED

PNA Argentine Bahia Grass

PLANT SCHEDULE

W

W

POLK STREET WEST

GO

RD

O N

A

VE

PP

34PNA

250 sf

EG

EG

AG

344 sf

AG

386 sf

LIN

MCA

LIN

EG

EG

PNA

395 sf

LEV

QV

LE

LEV

TM

LIN

TM

LIN

TM

MB

TM

LIN

MB

1 TM

LIN

MCA

MB

LE

PNA

643 sf

PNA

804 sf

TM

AF

LIN

LIN

QV

PNA

404 sf

LIN

PNA

395 sf

PP

PP

LE

MCA

PP

TM

PNA

1,132 sf

PP

LEV

LE

LEV

EXISTING PALM,TYP.

LIN

LE

PNA

284 sf

MCA

AF

LANDSCAPE LEGEND

P:

\2

6\

_C ity o f B ar to w

Po lk S tre et

C om m un ity C en te r\ dw g\ Co ns tru ct io n\

_L

2- 0_

LA

N.

dw g-

L2 .0

La nd sc ap e

Pl an

Ju n

, 2 ww an g

DRAWING NUMBER

PROJECT NUMBER

DRAWING TITLE

DE

SC

RI

PT

IO

N

DA

TE

NO

6/

/2

C D

O

R S E

B

LV

D

W

IN

TE

R P

A R K

FL

(6

9-

W W

W .C

A

TA

LY

S T-

D G

.C O

M

FI

R S T

LA

S T, P E

X X X X X

FI

R S T

LA

S T, P

LA

L A X

X X X X

Fl or id a

Fi rm

R eg is tr at io n N o.

20260026

PO

LK

S

TR

EE

T

CO

MM

UN

IT

Y

CE

NT

ER

P

OL

K

ST

RE

ET

BA

RT

OW

, F

LO

RI

DA

, 3

0%

C

ON

ST

RU

CT

IO

N

DO

CU

ME

NT

AT

IO

N

L2.00 0 10 20 40 60

GRAPHIC SCALE

N

Know what's below.

Call before you dig.

LANDSCAPE PLAN

NORTH BUFFER 113 LF

EA

ST

B

UF

FE

R

LF

F1

AutoCAD SHX Text 40.5'

AutoCAD SHX Text

BFP

AutoCAD SHX Text

BFP

AutoCAD SHX Text D

AutoCAD SHX Text Y

AutoCAD SHX Text H

AutoCAD SHX Text

BFP

AutoCAD SHX Text

BFP

AutoCAD SHX Text

WV

AutoCAD SHX Text

WV

AutoCAD SHX Text

IV

AutoCAD SHX Text S

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text W

AutoCAD SHX Text

IV

AutoCAD SHX Text

IV

AutoCAD SHX Text

(ASPHALT PAVEMENT)

AutoCAD SHX Text

EOP

AutoCAD SHX Text

EOP

AutoCAD SHX Text

PADDED PLAYGROUND AREA

AutoCAD SHX Text

EOP

AutoCAD SHX Text

EOP

AutoCAD SHX Text PARCEL ID: 25-30-06-000000-043050 OWNER: SCHOOL BOARD OF POLK COUNTY GAUSE ACADEMY OF LEADERSHIP

AutoCAD SHX Text

WV

AutoCAD SHX Text

6' CHAIN LINK FENCE

AutoCAD SHX Text

10' CHAIN LINK FENCE

AutoCAD SHX Text

6' CHAIN LINK FENCE

AutoCAD SHX Text

ELECTRIC TRANSFORMER

AutoCAD SHX Text 40.5'

AutoCAD SHX Text

PADDED PLAYGROUND AREA

(ASPHALT PAVEMENT)

SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT CAL SIZE

CANOPY TREES

AF 1 Florida Flame Red Maple Acer rubrum `Florida Flame` - 3" 12`-14` HT.

MB 3 D.D Blanchard Southern Magnolia Magnolia grandiflora 'D.D. Blanchard' - 3" CAL. 12`-14` HT., 5`-6` SPRD.

QV 2 Southern Live Oak Quercus virginiana - 3" CAL. 12'-14' HT.

UNDERSTORY TREES

LIN 20 Crape Myrtle Lagerstroemia indica `Natchez` - 3" CAL. 10'-12'; STANDARD

SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT SIZE SPACING

SHRUBS

PP 168 Podocarpus Podocarpus macrophylla 7 GAL. 3` HT. MIN, BUSH 36" O.C.

SHRUB AREAS

MCA 232 Pink Muhly Grass Muhlenbergia capillaris 3 GAL. 18"-24" HT. 24" O.C.

GROUND COVERS

AG 730 sf Perennial Peanut Arachis glabrata SOD

EG 718 Blue My Mind Dwarf Morning Glory Evolvulus glomeratus 'Blue My Mind' 1 GAL. 6" - 8" HT X 6"-8" SPRD.; FULL 16" O.C.

LE 280 Emerald Goddess Lilyturf Liriope muscari 'Emerald Goddess' 1 GAL. 8"-12` HT. 18" O.C.

TM 1,889 Minima Jasmine Trachelospermum asiaticum `Minima` 1 GAL. 4" -6" x 16"-18", MULCH FINE IN THIS AREA 12" O.C.

LEV 214 Varigated Lilyturf variegated liriope 1 GAL. 8"-12` HT. 18" O.C.

SOD/SEED

PNA 4,023 sf Argentine Bahia Grass Paspalum notatum 'Argentine' Sod

PLANT SCHEDULE

P:

\2

6\

_C ity o f B ar to w

Po lk S tre et

C om m un ity C en te r\ dw g\ Co ns tru ct io n\

_L

2- 0_

LA

N.

dw g-

La nd sc ap e Sc he du le Ju n

, 2 ww an g

DRAWING NUMBER

PROJECT NUMBER

DRAWING TITLE

DE

SC

RI

PT

IO

N

DA

TE

NO

6/

/2

C D

O

R S E

B

LV

D

W

IN

TE

R P

A R K

FL

(6

9-

W W

W .C

A

TA

LY

S T-

D G

.C O

M

FI

R S T

LA

S T, P E

X X X X X

FI

R S T

LA

S T, P

LA

L A X

X X X X

Fl or id a

Fi rm

R eg is tr at io n N o.

20260026

PO

LK

S

TR

EE

T

CO

MM

UN

IT

Y

CE

NT

ER

P

OL

K

ST

RE

ET

BA

RT

OW

, F

LO

RI

DA

, 3

0%

C

ON

ST

RU

CT

IO

N

DO

CU

ME

NT

AT

IO

N

L2.01

GENERAL LANDSCAPE NOTES

1. THE PLANT QUANTITIES SHOWN ON THE PLANT SCHEDULE ARE FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL QUANTITIES AND REPORTING ANY DISCREPANCIES TO THE LANDSCAPE ARCHITECT FOR CLARIFICATION

PRIOR TO CONTRACT AWARD AND COMMENCEMENT OF WORK.

2. ALL LANDSCAPE AREAS TO BE COVERED WITH 3” DEPTH 0F MELALEUCA MULCH.

3. CONTRACTOR SHALL NOT OVERTHROW MULCH ONTO PLANT MATERIAL.

4. CONTRACTOR SHALL USE MULCH FINES TO COVER PERENNIAL PEANUTS, ASIATIC JASMINE PLANTING BEDS.

5. CONTRACTOR SHALL REPLACE (BY EQUAL SIZE AND QUALITY) ANY AND ALL EXISTING PLANT MATERIAL/SOD DISTURBED OR

DAMAGED BY PLANT REMOVAL, RELOCATION, AND/OR INSTALLATION WORK.

LANDSCAPE TO BE IRRIGATED BY AN AUTOMATIC SYSTEM WITH RAIN SENSOR.

Know what's below.

Call before you dig.

LANDSCAPE

SCHEDULE

6\

_C ity o f B ar to w

Po lk

S tre et C om m un ity

C en te r\ dw g\

Co ns tru ct io n\

_L 2-

0_

LA

N.

dw g- L3

.0

La nd sc ap e De ta ils

Ju n

, 2 ww an g

DRAWING NUMBER

PROJECT NUMBER

DRAWING TITLE

DE

SC

RI

PT

IO

N

DA

TE

NO

6/

/2

C D

O

R S E

B

LV

D

W

IN

TE

R P

A R K

FL

(6

9-

W W

W .C

A

TA

LY

S T-

D G

.C O

M

FI

R S T

LA

S T, P E

X X X X X

FI

R S T

LA

S T, P

LA

L A X

X X X X

Fl or id a

Fi rm

R eg is tr at io n N o.

20260026

PO

LK

S

TR

EE

T

CO

MM

UN

IT

Y

CE

NT

ER

P

OL

K

ST

RE

ET

BA

RT

OW

, F

LO

RI

DA

, 3

0%

C

ON

ST

RU

CT

IO

N

DO

CU

ME

NT

AT

IO

N

L3.00

Know what's below.

Call before you dig.

LANDSCAPE

DETAILS

4" HARDWOOD

MULCH LAYER

REMOVE PLASTIC POT

OR SPLIT PEAT POT

PREPARED SOIL MIXTURE:

1/3 FDOT SAND,1/3 PEAT,

1/3 COMPOST

FINAL PLANTING SOIL MIX

TO BE ADJUSTED

BASED ON SOIL TESTING;

SEE LANDSCAPE NOTES

AND SPECS.

UNDISTURBED SUBGRADE

12" MIN

CLEAR

" M

IN

PR

EP

D

EP

TH

SEE PLANS FOR SPACING

NOTES:

1. TAMP PLANTING MIX AS PIT IS FILLED AROUND EACH PLANT BALL.

2. SOAK EACH PLANT BALL AND PIT IMMEDIATELY AFTER PLANTING.

3. SCARIFY THE ROOT BALL IF ROOT-BOUND IN ITS CONTAINER.

4. WHERE SHRUBS APPEAR IN BED AREAS, 3" OF MULCH SHALL BE SPREAD OVER THE

ENTIRE AREA WITHIN THE BED EDGE AS INDICATED ON THE PLANS.

5. DO NOT PRUNE BEFORE ACCEPTANCE.

6. REMOVE BURLAP FROM TOP THIRD OF ROOT BALL OR CAREFULLY REMOVE THE

PLASTIC CONTAINER, IF ONE IS USED.

7. BACKFILL WITH SOIL MIXTURE AS FOLLOWS: 1 PART COMPOSTED GARDEN SOIL - 1

PART SAND - 2 PARTS NATIVE TOPSOIL.

3" HARDWOOD MULCH LAYER.

CLEAR MULCH FROM WOODY

SHRUB STEMS TO PREVENT

FUNGAL GROWTH AND DECAY.

"V" TRENCH AROUND PLANTING BED

TOP OF ROOT BALL TO

BE 1"-2" HIGHER THAN

THE ADJACENT GRADE

UNDISTURBED SUBGRADE.

PROVIDE SUBGRADE PEDESTAL

FOR EACH SHRUB INSTALLED,

TO AVOID SETTLEMENT.

PREPARED PLANTING SOIL

1/3 FDOT SAND,1/3 PEAT, 1/3 COMPOST

FINAL PLANTING SOIL MIX TO BE ADJUSTED

BASED ON SOIL TESTING; SEE LANDSCAPE

NOTES AND SPECS.

O.C. SPACING

O.

C.

S

PA

CI

NG

NOTE:

THE PERIMETER OF ALL CURVED PLANTING BEDS

SHALL BE PLANTED WITH A ROW OF SHRUBS AS

SHOWN IN THE PLANS AND AT THE SPACING

SHOWN IN THE PLANT LIST. INTERIOR PORTIONS

OF EACH BED SHALL BE PLANTED AT APPROPRIATE

SPACING ACCORDING TO THIS PLANT SPACING

DETAIL.

18" MIN. SETBACK

FOR SHRUBS FROM

CURBS, EDGE OF

PAVEMENT, OR BED

LINES.

ALL SHRUBS/GROUNDCOVER TO

BE TRIANGULAR SPACING.

SEE PLANT LIST FOR (O.C.) SPACING

12" MIN. SETBACK FOR GROUNDCOVERS FROM CURBS,

EDGE OF PAVEMENT, OR BEDLINES

GROUDCOVER PLANTING1 SCALE: N.T.S.

BLACK POROUS HOSE

SOIL BERM 6" (TYP.)

3" DEPTH OF MULCH MIN. (TYP.)

6" CLEAR OF TRUNK.

PREPARED PLANTING SOIL

1/3 FDOT SAND,1/3 PEAT, 1/3 COMPOS

FINAL PLANTING SOIL MIX TO BE

ADJUSTED BASED ON SOIL TESTING; S

LANDSCAPE NOTES AND SPECS.

UNDISTURBED SOIL

16" x 6" GALVANIZED TURN BUCKLE;

2500 LBS. BREAK STRENGTH

1. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.

2. CONTRACTOR TO PRUNE ANY TREES WITHIN SIGHT TRIANGLES ACCORDING TO FDOT INDEX 546 - SIGHT DISTANCE AT

INTERSECTIONS

TREE PIT 2X

ROOTBALL DIA.

AUGER ANCHOR HC4-30:

4" SCREW, 30" LENGTH

PLAN VIEW

16" GALVANIZED WIRE;

4,200 LBS. BREAK STRENGTH

NOTE:

SET TO OF ROOT BALL

3" ABOVE FINISH GRADE

60°

2 TREE HEIGHT

120°120°

120°

1" DIA., WHITE 18" PVC PIPE.

BURY 6" INTO SOIL, TYP.

OF STAKING

24"

ALL SOD LAID WITH ALTERNATING

AND BUTTING JOINTS

18"

NOTE: PROVIDE 2"-3" OF TOP SOIL FOR FINAL GRADING PRIOR TO LAY DOWN SOD

SHRUB PLANTING2 SCALE: N.T.S.

SHRUB SPACING4 SCALE: N.T.S.

TREE PLANTING (3" CAL. AND ABOVE)5 SCALE: N.T.S.

TREE PLANTING (LESS THAN 3" CAL.)7 SCALE: N.T.S.

SOD PLANTING3 SCALE: N.T.S.

TREE PIT

2X ROOTBALL DIA.

PREASSEMBLED PALM SAVER

COLLAR BY STAKING SYSTEMS INC.

OR APPROVED EQUAL.

1/3 HEIGHT

OF PALM C.T.

PREPARED PLANTING SOIL

1/3 FDOT SAND,1/3 PEAT, 1/3 COMPOST

FINAL PLANTING SOIL MIX TO BE ADJUSTED

BASED ON SOIL TESTING; SEE LANDSCAPE

NOTES AND SPECS.

(3) 2 X 4 WOOD BRACES

60°

PLAN VIEW OF

STAKING

120°120°

120°

SOIL BERMS ARE TO BE

CONSTRUCTED AT RIGHT

ANGLES TO THE PLANT OR

IN THE POSITION WHICH

WILL MOST EFFECTIVELY

RETAIN WATER AT THE BASE

OF THE PLANT.

CONTRACTOR SHALL ASSURE PERCOLATION

OF ALL PLANTING PITS PRIOR TO

INSTALLATION.

CABBAGE PALMS SHALL BE HURRICANE CUT TO

REMOVE ALL FRONDS. CUT THE LEADER OR

CENTRAL BUD BACK, LEAVING ONLY SECTIONS

OF THE FRONDS CLOSE TO THE PALM NUT.

UNLESS OTHERWISE SPECIFIED IN THE PLANT

LIST

NOTE:

UNDISTURBED SOIL

(3) 2 x 4 STAKES

SOIL BERM 6" (TYP.)

1" DEPTH OF MULCH MAX. (TYP.)

6" CLEAR OF TRUNK.

SET TOP OF ROOT BALL

3" ABOVE FINISH GRADE

PALM PLANTING6 SCALE: N.T.S.

BIKE RACK8 SCALE: N.T.S.

TREE PIT 2X

ROOTBALL DIA.

CONTRACTOR SHALL

ASSURE PERCOLATION OF

ALL PLANTING PITS PRIOR

TO INSTALLATION.

NOTE:

ARBOR TIE STAKING

COMPONENTS

MANUFACTURED BY

STAKING SYSTEMS INC. OR

APPROVED EQUAL.

UNDISTURBED SOIL

LODGE POLES EXTEND 2'

INTO UNDISTURBED SOIL

PREPARE PLANTING SOIL : 1/3 FDOT

SAND,1/3 PEAT, 1/3 COMPOST. FINAL

PLANTING SOIL MIX TO BE ADJUSTED

BASED ON SOIL TESTING; SEE

LANDSCAPE NOTES AND SPECS.

2" DIA. X 8' LONG LODGE POLE

OR APPROVED EQUAL

SET TOP OF ROOT BALL

3" ABOVE FINISH GRADE

SOIL BERM 6" (TYP.)

1" DEPTH OF MULCH MAX. (TYP.)

6" CLEAR OF TRUNK.

36" MAX. DIAMETER

MULCH RING, TYP.

PLAN VIEW OF STAKING

6\

_C ity o f B ar to w

Po lk

S tre et C om m un ity

C en te r\ dw g\

Co ns tru ct io n\

_L 2-

0_

LA

N.

dw g- La nd sc ap e

Sp ec ifi ca tio ns

Ju n

, 2 ww an g

DRAWING NUMBER

PROJECT NUMBER

DRAWING TITLE

DE

SC

RI

PT

IO

N

DA

TE

NO

6/

/2

C D

O

R S E

B

LV

D

W

IN

TE

R P

A R K

FL

(6

9-

W W

W .C

A

TA

LY

S T-

D G

.C O

M

FI

R S T

LA

S T, P E

X X X X X

FI

R S T

LA

S T, P

LA

L A X

X X X X

Fl or id a

Fi rm

R eg is tr at io n N o.

20260026

PO

LK

S

TR

EE

T

CO

MM

UN

IT

Y

CE

NT

ER

P

OL

K

ST

RE

ET

BA

RT

OW

, F

LO

RI

DA

, 3

0%

C

ON

ST

RU

CT

IO

N

DO

CU

ME

NT

AT

IO

N

L3.10

Know what's below.

Call before you dig.

LANDSCAPE

SPECIFICATIONS

6\

_C ity o f B ar to w

Po lk

S tre et C om m un ity

C en te r\ dw g\

Co ns tru ct io n\

_L 2-

0_

LA

N.

dw g- L3

.1

La nd sc ap e Sp ec ifi ca tio ns Ju n

, 2 ww an g

DRAWING NUMBER

PROJECT NUMBER

DRAWING TITLE

DE

SC

RI

PT

IO

N

DA

TE

NO

6/

/2

C D

O

R S E

B

LV

D

W

IN

TE

R P

A R K

FL

(6

9-

W W

W .C

A

TA

LY

S T-

D G

.C O

M

FI

R S T

LA

S T, P E

X X X X X

FI

R S T

LA

S T, P

LA

L A X

X X X X

Fl or id a

Fi rm

R eg is tr at io n N o.

20260026

PO

LK

S

TR

EE

T

CO

MM

UN

IT

Y

CE

NT

ER

P

OL

K

ST

RE

ET

BA

RT

OW

, F

LO

RI

DA

, 3

0%

C

ON

ST

RU

CT

IO

N

DO

CU

ME

NT

AT

IO

N

L3.11

Know what's below.

Call before you dig.

LANDSCAPE

SPECIFICATIONS

3.6 SUBSTANTIAL COMPLETION, PAYMENT AND GUARANTEE

A. Substantial Completion and Payment:

1. Submit request for inspection of Substantial Completion in writing to the Contracting Officer at least one week prior to anticipated date of inspection.

2. Submit Maintenance Manual as specified in 1.04 (C) for Park's information and Contracting

Officer's approval, containing full details for care and maintenance of landscape work, personnel and procedures, and weekly schedule for maintenance.

3. Review the Work jointly with the Contracting Officer for Substantial Completion.

4. Upon completion of repairs and replacements found necessary at time of review, the Contracting

Officer will confirm the date of Substantial completion of the Work.

5. Upon receipt of confirmation of Substantial Completion, Contractor will be paid amount of money then due, less the value of the Maintenance Period, amounts already paid, and other deductions allowed to be made,

6. Substantial Completion constitutes the beginning date of the Maintenance Period and One-Year

Guarantee Period.

B. Basis of Acceptance:

1. Planted trees, shrubs and groundcovers will be counted as individual units, complete, in place and planted in accordance with the plans and specifications. Each unit will include the installed plant, topsoil mix, mulch and staking apparatus.

2. Maintenance Period will be counted as a lump sum item.

3. Plant pit excavation in shot-rock (if required) will be counted as individual units. Necessity will be determined by the Contracting Officer.

4. The cost of mobilization (including all provisions of General Requirements and General and

Supplementary Conditions), clean-up, guarantee and maintenance will Substantial Completion as specified herein are considered incidental to the Work and will not be counted as separate items for payment.

C. Guarantee:

1. Guarantee all materials and workmanship for a period of one (1) year beyond the Date of

Substantial Completion.

2. When Work is substantially completed in parts, the Guarantee Period extends from each

Substantial Completion date to the terminal date of the last Guarantee Period. thus, all Guarantee

Periods terminate at the same time.

3. During the period of the Guarantee, replace with no additional compensation, and as soon as weather permits, all dead plant materials and all plant materials not in a thriving condition; replace all other materials which are unsatisfactory in the opinion of the Contracting Officer; make good any other damage, loss destruction, or failure to flourish sufficiently as the result of inferior or defective materials or workmanship, including, but not limited to inadequate drainage.

4. Repair grades and other Work necessitated due to planting replacements.

5. If the replacement plant is not acceptable during or at the end of the Guarantee Period, the

Contracting Officer may elect either subsequent replacement or credit.

6. Guarantee applies to losses other than those due to Act of God, vandalism, or Park neglect, as determined by the Contracting Officer. Contractor agrees to replace such plant material at original contract price when directed by the Contracting Officer.

3.7 FINAL INSPECTION AND FINAL ACCEPTANCE

A. At the end of the Guarantee Period submit request for inspection for Final Acceptance to the

Contracting Officer at least one week prior to anticipated date of inspection. Include list of Work substantially completed list of Work replaced during Guarantee Period.

B. Upon request for Inspection, jointly review with Contracting Officer all guaranteed Work for Final

Acceptance.

C. Upon completion by the Contractor of all required repairs and replacements, the Contracting

Officer will confirm the date of Final Acceptance of the Work.

END OF SECTION 32 93 10

LEGEND

POINT OF CONNECTION TO STUB OUT (BY OTHERS) - 26.3 GPM AT 45 PSI REQUIRED

HUNTER HCC-800-M METAL WALL MOUNT CONTROLLER

HUNTER WSS-SEN SENSOR (MOUNT ON EAVE OF BUILDING.)

1-1/2'' SOLVENT WELD PVC MAIN LINE ROUTING

HUNTER ICV-101G-AS-ADJ 1'' VALVE ASSEMBLY

HUNTER ICV-151G-AS-ADJ 1.5'' VALVE ASSEMBLY

SOLVENT WELD PVC ZONE PIPE ROUTING

SCHEDULE 40 PVC SLEEVE LOCATION

HUNTER HDL-COP .09 GPH, 12'' O.C. DRIP TUBING

HUNTER PROS-06-PRS30 SPRINKLER WITH 5Q NOZZLE

HUNTER PROS-06-PRS40 SPRINKLER WITH MPCORNER NOZZLE

HUNTER PROS-06-PRS40 SPRINKLER WITH MP1000-90 NOZZLE

HUNTER PROS-06-PRS40 SPRINKLER WITH MP2000-90 NOZZLE

HUNTER PROS-06-PRS40 SPRINKLER WITH MP3000-90 NOZZLE

HUNTER PROS-06-PRS40 SPRINKLER WITH MPLCS-515 NOZZLE

HUNTER PROS-06-PRS40 SPRINKLER WITH MPRCS-515 NOZZLE

HUNTER PROS-06-PRS40 SPRINKLER WITH MPSS-530 NOZZLE

VALVE STATION, SIZE, APPLICATION, AND NOMINAL GALLONAGE

NOTE :

PROVIDE AN ALTERNATE BID ITEM FOR AN INSTALLED MASTER VALVE AND FLOW

SENSOR AT THE POINT OF CONNECTIONWITH WIING TO CONTROLLER.

.22 .22

.44 .86

.45 1.82

.49

T

POC

C

SS

W

W

POLK STREET WEST

GO

RD

O N

A

VE

T T T T

T TT T

T T

T T

T TT TT T

T T T T

T T

T T

T T

T T

T T

T T

T T

T T

T T T

T

T T

T T

T T

T T

T T

T T

T T

T T

210 L.F.

3.2 GPM

420 L.F.

6.3 GPM

180 L.F.

2.7 GPM

380 L.F.

5.7 GPM

400 L.F.

6.0 GPM

480 L.F.

7.2 GPM

490 L.F.

7.4 GPM

230 L.F.

3.4 GPM

1450 L.F.

22.0 GPM

590 L.F.

8.8 GPM

160 L.F.

2.4 GPM

430 L.F.

6.4 GPM

690 L.F.

10.4 GPM

220 L.F.

3.3 GPM

(2 ROWS)

110 L.F.

1.7 GPM

(2 ROWS)

220 L.F.

5.0 GPM

(2 ROWS)

510 L.F.

7.6 GPM

50 L.F.

0.8 GPM

250 L.F.

3.8 GPM

(2 ROWS)

80 L.F.

1.2 GPM

(2 ROWS)

.19

.49

.49

.35

.49

.45

.49

.45

.45

.45

.49

.49

.49

.49

.22

.22

.44

.44

.44

.44

.44 .44

.44

.44

.49

.49

.49

.49

.49

.49

.43

.86

.43

.43

.43

.22.22

.43

.86 .86

.43

.43

.43

.43

.45

.45

1.82

.49

.22

.22

.44 .44

.22

.22

.44

.44

.44

.44

.44

.44

.44

.45

.45

.45

.45

.45

.45

.45

.22

.22

.45

.45

.45

.45

.49

.49

.49

.49

.49

.49

POC

C SS

.49

IRRIGATION ITEMS SHOWN UNDER PAVEMENT ARE

SHOWN AS SUCH FOR GRAPHIC CLARITY ONLY.

INSTALL ALL ITEMS (OTHER THAN SLEEVED ITEMS) IN

THE LANDSCAPE.

IRRIGATION ITEMS SHOWN UNDER PAVEMENT ARE

SHOWN AS SUCH FOR GRAPHIC CLARITY ONLY.

INSTALL ALL ITEMS (OTHER THAN SLEEVED ITEMS) IN

THE LANDSCAPE.

520 L.F.

7.3 GPM

(2 ROWS)

4''

1''

1''

4''

1''

1''

4''

1''

1''

1''

1''

2''

4'' 1'' 1''

2''

4''

4''

4''

4'' 11

4''

4''

4''

4'' 11

4''

2''

6'' SL.

6'' SL.

4'' SL.

4'' SL.

4'' SL.

4'' SL.

4'' SL.

4''

4'' SL.

4'' SL.4'' SL.

3'' SL.

3'' SL.

3'' SL.

3'' SL.

3'' SL.

3'' SL.

INSTALL 1'' PVC PIPING FROM

VALVE #PS1, COMMON, TO ALL

TREE SPRAYS

ON THE PLANS. (112 EA.)

DO NOT CONNECT TO ANY

OTHER PIPING.

4'' SL.

P:

\2

6\

_C ity o f B ar to w

Po lk

S tre et C om m un ity

C en te r\ dw g\

Co ns tru ct io n\

_L 3-

0_

IR

R.

dw g- L6

.0

Ir rig at io n Pl an Ju n

, 2 ww an g

DRAWING NUMBER

PROJECT NUMBER

DRAWING TITLE

DE

SC

RI

PT

IO

N

DA

TE

NO

6/

/2

C D

O

R S E

B

LV

D

W

IN

TE

R P

A R K

FL

(6

9-

W W

W .C

A

TA

LY

S T-

D G

.C O

M

FI

R S T

LA

S T, P E

X X X X X

FI

R S T

LA

S T, P

LA

L A X

X X X X

Fl or id a

Fi rm

R eg is tr at io n N o.

20260026

PO

LK

S

TR

EE

T

CO

MM

UN

IT

Y

CE

NT

ER

P

OL

K

ST

RE

ET

BA

RT

OW

, F

LO

RI

DA

, 3

0%

C

ON

ST

RU

CT

IO

N

DO

CU

ME

NT

AT

IO

N

L6.00 0 10 20 40 60

GRAPHIC SCALE

N

Know what's below.

Call before you dig.

IRRIGATION PLAN

AutoCAD SHX Text R

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

GPM

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

STA.

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

AutoCAD SHX Text

PS#

AutoCAD SHX Text

AutoCAD SHX Text

APP

AutoCAD SHX Text 40.5'

AutoCAD SHX Text D

AutoCAD SHX Text Y

AutoCAD SHX Text H

AutoCAD SHX Text

BFP

AutoCAD SHX Text

BFP

AutoCAD SHX Text

WV

AutoCAD SHX Text

WV

AutoCAD SHX Text

IV

AutoCAD SHX Text S

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text W

AutoCAD SHX Text

IV

AutoCAD SHX Text

IV

AutoCAD SHX Text

(ASPHALT PAVEMENT)

AutoCAD SHX Text

PADDED PLAYGROUND AREA

AutoCAD SHX Text PARCEL ID: 25-30-06-000000-043050 OWNER: SCHOOL BOARD OF POLK COUNTY GAUSE ACADEMY OF LEADERSHIP

AutoCAD SHX Text

WV

AutoCAD SHX Text

6' CHAIN LINK FENCE

AutoCAD SHX Text

10' CHAIN LINK FENCE

AutoCAD SHX Text

6' CHAIN LINK FENCE

AutoCAD SHX Text

ELECTRIC TRANSFORMER

AutoCAD SHX Text 40.5'

AutoCAD SHX Text

PADDED PLAYGROUND AREA

AutoCAD SHX Text

(ASPHALT PAVEMENT)

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text R

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text L

AutoCAD SHX Text R

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text L

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text R

AutoCAD SHX Text L

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

GPM

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

STA.

AutoCAD SHX Text

TYPE

AutoCAD SHX Text 1.5''

AutoCAD SHX Text

PS2

AutoCAD SHX Text 25.2

AutoCAD SHX Text

DRIP

AutoCAD SHX Text

GPM

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

STA.

AutoCAD SHX Text

TYPE

AutoCAD SHX Text 1''

AutoCAD SHX Text

PS1

AutoCAD SHX Text 11.2

AutoCAD SHX Text

TREES

AutoCAD SHX Text

GPM

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

STA.

AutoCAD SHX Text

TYPE

AutoCAD SHX Text 1''

AutoCAD SHX Text

PS3

AutoCAD SHX Text 12.5

AutoCAD SHX Text

DRIP

AutoCAD SHX Text

GPM

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

STA.

AutoCAD SHX Text

TYPE

AutoCAD SHX Text 1.5''

AutoCAD SHX Text

PS4

AutoCAD SHX Text 22.7

AutoCAD SHX Text

DRIP

AutoCAD SHX Text

GPM

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

STA.

AutoCAD SHX Text

TYPE

AutoCAD SHX Text 1''

AutoCAD SHX Text

PS5

AutoCAD SHX Text 13.2

AutoCAD SHX Text

TURF

AutoCAD SHX Text

GPM

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

STA.

AutoCAD SHX Text

TYPE

AutoCAD SHX Text 1.5''

AutoCAD SHX Text

PS6

AutoCAD SHX Text 25.0

AutoCAD SHX Text

TURF

AutoCAD SHX Text

GPM

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

STA.

AutoCAD SHX Text

TYPE

AutoCAD SHX Text 1.5''

AutoCAD SHX Text

PS7

AutoCAD SHX Text 26.3

AutoCAD SHX Text

DRIP

AutoCAD SHX Text

GPM

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

STA.

AutoCAD SHX Text

TYPE

AutoCAD SHX Text 1.5''

AutoCAD SHX Text

PS8

AutoCAD SHX Text 25.3

DRIP

\2

6\

_C ity o f B ar to w

Po lk

S tre et C om m un ity

C en te r\ dw g\

Co ns tru ct io n\

_L 3-

0_

IR

R.

dw g- L7

.0

Ir rig at io n No te s

Ju n

, 2 ww an g

DRAWING NUMBER

PROJECT NUMBER

DRAWING TITLE

DE

SC

RI

PT

IO

N

DA

TE

NO

6/

/2

C D

O

R S E

B

LV

D

W

IN

TE

R P

A R K

FL

(6

9-

W W

W .C

A

TA

LY

S T-

D G

.C O

M

FI

R S T

LA

S T, P E

X X X X X

FI

R S T

LA

S T, P

LA

L A X

X X X X

Fl or id a

Fi rm

R eg is tr at io n N o.

20260026

PO

LK

S

TR

EE

T

CO

MM

UN

IT

Y

CE

NT

ER

P

OL

K

ST

RE

ET

BA

RT

OW

, F

LO

RI

DA

, 3

0%

C

ON

ST

RU

CT

IO

N

DO

CU

ME

NT

AT

IO

N

L7.00

IRRIGATION

NOTES

AutoCAD SHX Text

TESTING

AutoCAD SHX Text

TEFLON TAPE.

AutoCAD SHX Text

FITTING AND PIPE CONNECTIONS

AutoCAD SHX Text

SWING JOINTS. INSTALL ALL OF THESE EXCEPTIONS USING ONE INCH

AutoCAD SHX Text

LIQUID TEFLON EXCEPT SPRINKLER HEADS, ELECTRIC VALVE CONNECTIONS AND

AutoCAD SHX Text

SOLVENT CEMENT MANUFACTURER. SEAL ALL THREADED PVC FITTINGS WITH

AutoCAD SHX Text

SOLVENT WELD ON THAT PIPE UNLESS RECOMMENDED OTHERWISE BY THE

AutoCAD SHX Text

WATER IN THE PIPE FOR AT LEAST TWENTY-FOUR HOURS AFTER MAKING A

AutoCAD SHX Text

FULLY ENGAGE ALL JOINTS WHILE CEMENTING.

AutoCAD SHX Text

SQUARE CUT, CLEAN AND PRIME ALL JOINTS BEFORE CEMENTING.

AutoCAD SHX Text

ONE (1) HOUR TO SET UP BEFORE MOVING OR HANDLING. DO NOT PERMIT

AutoCAD SHX Text

SOLVENT WELD CONNECTIONS. ALLOW SOLVENT WELDED JOINTS AT LEAST

AutoCAD SHX Text

ASTM D2855. PRIME ALL FITTINGS WITH PURPLE PRIMER BEFORE MAKING

AutoCAD SHX Text

PVC FITTINGS - MAKE ALL SOLVENT WELD JOINTS IN ACCORDANCE WITH

AutoCAD SHX Text

TESTING

AutoCAD SHX Text

WARRANTY

AutoCAD SHX Text

T = 2L/3 WHERE T = TIME IN SECONDS

AutoCAD SHX Text

MINIMUM TIME OF:

AutoCAD SHX Text

IN PIPELINE.

AutoCAD SHX Text

AUTOMATIC CONTROLLER INSTALLATION

AutoCAD SHX Text

BY VALVE NUMBER.

AutoCAD SHX Text

REINFORCED TAPE.

AutoCAD SHX Text

INSTALLING ELECTRIC VALVE CONTROL WIRING

AutoCAD SHX Text

SLEEVE. INSTALL CONTROL WIRING THROUGH WALLS, FLOORS, AND SLABS IN

AutoCAD SHX Text

FLUSH ALL PIPELINES BEFORE SPRINKLERS ARE INSTALLED. MAINTAIN A

AutoCAD SHX Text

MINIMUM PIPE VELOCITY OF THREE FEET PER SECOND AND FLUSH FOR A

AutoCAD SHX Text

& L = PIPE LENGTH IN FEET FROM INLET POINT TO MOST DISTANT POINT

AutoCAD SHX Text

INSTALL WIRING IN THE SAME TRENCH AND ALONG THE SAME ROUTE AS, AND

AutoCAD SHX Text

UNDERNEATH THE MAIN LINE EXCEPT IN LOCATIONS WHERE THE WIRE WILL PASS

AutoCAD SHX Text

UNDER PAVING. AT THOSE LOCATIONS INSTALL THE WIRE INSIDE OF A PVC

AutoCAD SHX Text

CONNECTION. PROVIDE EXPANSION COILS OF WIRE AT NO MORE THAN 100

AutoCAD SHX Text

USE A CONTINUOUS WIRE BETWEEN THE CONTROLLER AND VALVE. MAKE AN

AutoCAD SHX Text

EXPANSION LOOP OF A MINIMUM 12 INCHES DIAMETER AT EACH WIRE

AutoCAD SHX Text

TAPE WIRING TOGETHER AT INTERVALS OF TEN FEET, USING 1/4 INCH FIBER

AutoCAD SHX Text

PVC SLEEVES. INSTALL (2) EXTRA WIRES POWER FROM EACH CONTROLLER TO

AutoCAD SHX Text

THE FARTHEST VALVE IN EACH DIRECTION OPERATED BY THAT CONTROLLER.

AutoCAD SHX Text

FOOT INTERVALS AND AT EACH DIRECTION CHANGE IN THE WIRE ROUTING.

AutoCAD SHX Text

PROVIDE A SEPARATE POWER WIRE FOR EACH CONTROL VALVE.

AutoCAD SHX Text

ATTACH PERMANENT MARKINGS AT EACH END OF EACH WIRE TO IDENTIFY IT

AutoCAD SHX Text

FLUSHING PIPELINES

AutoCAD SHX Text

INSPECTIONS

AutoCAD SHX Text

COUNTY PLUMBING CODES. IF LEAKAGE OCCURS, REMEDY THE LEAKAGE PROBLEM

AutoCAD SHX Text

AND ASSURE THAT ANY TESTS OF THE SYSTEM MAIN LINE MEET THE APPLICABLE

AutoCAD SHX Text

CONTINUOUSLY, AT A PRESSURE OF NO LESS THAN 100 PSI WITH NO LEAKS

AutoCAD SHX Text

OR OWNER'S REPRESENTATIVE, FOR A PERIOD OF NO LESS THAN FOUR HOURS,

AutoCAD SHX Text

PRESSURE TEST THE SYSTEM MAIN LINE, IN THE PRESENCE OF THE OWNER

AutoCAD SHX Text

PRESSURE TEST THE SYSTEM MAIN LINE BEFORE APPRECIABLY BACKFILLING.

AutoCAD SHX Text

REPRESENTATIVE IN ADVANCE THAT EACH ITEM IS READY FOR INSPECTION

AutoCAD SHX Text

THE FOLLOWING INSPECTIONS ARE REQUIRED. NOTIFY OWNER OR OWNER'S

AutoCAD SHX Text

OPERATING PRESSURE CONDITIONS BEFORE ANY GROUND COVER OR TURF IS

AutoCAD SHX Text

THE CONTRACTOR SHALL ISSUE TO THE OWNER OR OWNER'S REPRESENTATIVE

AutoCAD SHX Text

COVERAGE TESTS - CONDUCT SPRINKLER COVERAGE TESTS UNDER NORMAL

AutoCAD SHX Text

NOTIFY 48 HOURS IN ADVANCE.

AutoCAD SHX Text

AS INDICATED BELOW:

AutoCAD SHX Text

FINAL INSPECTION - NOTIFY 48 HOURS IN ADVANCE.

AutoCAD SHX Text

SPRINKLER COVERAGE TEST - NOTIFY 48 HOURS IN ADVANCE.

AutoCAD SHX Text

SPRINKLER AND VALVE LOCATIONS PRIOR TO BEGINNING CONSTRUCTION -

AutoCAD SHX Text

INSPECTION OF FLAGGED UNDERGROUND MAINLINE PIPING, SLEEVES,

AutoCAD SHX Text

CONTROLLER, AND HIS LABOR.

AutoCAD SHX Text

DRAWING OF RECORD

AutoCAD SHX Text

OF NOT LESS THAN ONE YEAR ON ALL SPRINKLERS, VALVES, THE

AutoCAD SHX Text

A CERTIFICATE OF WARRANTY OF THE IRRIGATION SYSTEM FOR A PERIOD

AutoCAD SHX Text

MINIMIZE OVER SPRAY ONTO PAVED SURFACES AND BUILDINGS.

AutoCAD SHX Text

PROVIDE UNIFORM PRECIPITATION OVER THE IRRIGATED AREA AND

AutoCAD SHX Text

PLANTED. CORRECT AND FIELD ADJUST SPRINKLER ORIENTATION TO

AutoCAD SHX Text

UNTIL A SUCCESSFUL TEST IS PERFORMED.

AutoCAD SHX Text

AND RETEST. REPEAT THIS PROCESS AS MANY TIMES AS NECESSSARY

AutoCAD SHX Text

VALVE BOXES.

AutoCAD SHX Text

VALVE INSTALLATION

AutoCAD SHX Text

BEFORE INSTALLATION.

AutoCAD SHX Text

PROVIDE THE BEST COVERAGE IN SLOPED AREAS.

AutoCAD SHX Text

LOCATION - VERIFY LOCATION WITH OWNER OR OWNER'S REPRESENTATIVE

AutoCAD SHX Text

INSTALL ALL AUTOMATIC ZONE VALVES AND GATE VALVES IN VALVE BOXES.

AutoCAD SHX Text

INSTALL ANY MAIN LINE ISOLATION VALVES AND QUICK COUPLING VALVES IN

AutoCAD SHX Text

VERIFY THAT SUFFICIENT SLEEVING EXISTS TO ALLOW ROUTING OF THE VALVE

AutoCAD SHX Text

NUMBER EACH ZONE VALVE BOX ON THE UNDERSIDE AND TOPSIDE OF EACH

AutoCAD SHX Text

VALVE BOX COVER WITH BLACK WATERPROOF MARKER FOR REFERENCE.

AutoCAD SHX Text

INSTALLATION OF SPRAY HEADS.

AutoCAD SHX Text

INSTALLATION SCHEDULE - INSTALL SPRAY HEADS AFTER THE SPRINKLER

AutoCAD SHX Text

BODY ASSEMBLIES HAVE BEEN CLEANLY FLUSHED.

AutoCAD SHX Text

ORIENTATION - INSTALL POP-UP UNITS IN A PLUMB POSITION AND FIELD

AutoCAD SHX Text

ADJUST SPRINKLER HEADS TO OBTAIN COMPLETE COVERAGE OF IRRIGATED

AutoCAD SHX Text

AREA WITH MINIMUM OVER SPRAY ONTO PAVED SURFACES. HEADS ARE TO BE

AutoCAD SHX Text

LOCATED ON A MAXIMUM SPACING OF 55% OF THE SPRINKLER COVERAGE

AutoCAD SHX Text

DISTANCE AND CLOSER WHERE INDICATED. ADJUST NOZZLE DISTANCE AS

AutoCAD SHX Text

WIRING FROM THE CONTROLLER TO EACH VALVE.

AutoCAD SHX Text

STRUCTURES AND PAVEMENT. ALIGN POP-UP SPRAY HEADS IN A VERTICAL

AutoCAD SHX Text

ORIENTATION AS SHOWN IN THE DETAILS. ADJUST AS NECESSARY TO

AutoCAD SHX Text

NEEDED TO COVER PLANT MATERIALS AND MINIMIZE OVER SPRAY ON

AutoCAD SHX Text

PROPER COVERAGE.

AutoCAD SHX Text

RAIN GAUGE

AutoCAD SHX Text

MISCELLANEOUS

AutoCAD SHX Text

LEAST TWO FIXED OBJECTS, CONTROLLER, AND WIRE ROUTING. THIS PLAN

AutoCAD SHX Text

ASSURE THAT THE SYSTEM PROVIDES 100% COVERAGE OF ALL LANDSCAPED AREAS.

AutoCAD SHX Text

PRIOR TO INSTALLATION IF IN ANY DOUBT OF HEAD, LINE OR ZONE PLACEMENT.

AutoCAD SHX Text

FURNISH THE OWNER WITH ANY KEYS FOR LOCKABLE ITEMS ON THIS SYSTEM.

AutoCAD SHX Text

OPERATING AND ELECTRICAL-RELATED EQUIPMENT, BOUND IN ONE FOLDER.

AutoCAD SHX Text

SUPPLY TO THE OWNER ALL INSTRUCTION SHEETS AND PARTS LISTS COVERING ALL

AutoCAD SHX Text

OF TWO (2) DIMENSIONS TAKEN FROM FIXED OBJECTS TO EACH AUTOMATIC

AutoCAD SHX Text

ANY IRRIGATION ITEMS NORMALLY INSTALLED IN LANDSCAPE AREAS THAT ARE SHOWN

AutoCAD SHX Text

OUTSIDE OF LANDSCAPE AREAS OR OUTSIDE OF THE PROPERTY LINES ARE SHOWN AS

AutoCAD SHX Text

SUCH FOR GRAPHIC CLARITY ONLY. INSTALL THESE ITEMS INSIDE OF PROPERTY

AutoCAD SHX Text

LINES AND IN LANDSCAPE AREAS. CONTACT THE OWNER OR LANDSCAPE ARCHITECT

AutoCAD SHX Text

ASSURE THAT EACH CONTROLLER IS INTERFACED WITH A RAIN SWITCH WHICH WILL SHUT

AutoCAD SHX Text

THE SYSTEM OFF IN CASE OF RAIN OR FREEZING WEATHER.

AutoCAD SHX Text

ADDITIONAL SUBMITTALS

AutoCAD SHX Text

VALVE AND MANUAL CONTROL VALVE.

AutoCAD SHX Text

MAY BE AN ADAPTATION OF THE IRRIGATION DESIGN WITH ANY CHANGES

AutoCAD SHX Text

DRAFTED ON THIS PLAN. THE DRAWING SHALL ALSO PROVIDE A MINIMUM

AutoCAD SHX Text

SIZES AND THE ENDS OF SLEEVING LOCATIONS AS MEASURED FROM AT

AutoCAD SHX Text

ALL SPRINKLERS, INCLUDING BODY TYPES AND NOZZLES, PIPE, INCLUDING

AutoCAD SHX Text

IRRIGATION SYSTEM AND ALL NEWLY INSTALLED COMPONENTS INCLUDING

AutoCAD SHX Text

REPRODUCIBLE PLAN SHOWING ALL CHANGES MADE TO THE EXISTING

AutoCAD SHX Text

THE LANDSCAPE ARCHITECT RESERVES THE RIGHT TO MAKE MINOR FIELD CHANGES.

AutoCAD SHX Text

ALL APPLICABLE CODES SHALL TAKE PRECEDENCE OVER THESE PLANS. IT IS THE

AutoCAD SHX Text

REPORT ANY DISCREPANCIES TO THE LANDSCAPE ARCHITECT BEFORE COMMENCING

AutoCAD SHX Text

WITH THE INSTALLATION.

AutoCAD SHX Text

FIELD ADJUST NOZZLE SELECTION LOCATIONS AND PLUMB OF SPRINKLERS TO PROVIDE

AutoCAD SHX Text

CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH ALL APPLICABLE CODES.

AutoCAD SHX Text

THE CONTRACTOR SHALL SUPPLY TO THE OWNER A DRAFTED, SCALED,

AutoCAD SHX Text

ELECTRIC VALVES

AutoCAD SHX Text

WIRE

AutoCAD SHX Text

USE RED #14 AWG WIRE FOR ALL VALVE POWER WIRES.

AutoCAD SHX Text

USE WHITE #14 AWG WIRE FOR ALL VALVE COMMON WIRES.

AutoCAD SHX Text

VAC APPLICATIONS.

AutoCAD SHX Text

CONTROLLER

AutoCAD SHX Text

PART 3 - EXECUTION

AutoCAD SHX Text

OWNER'S REPRESENTATIVE BEFORE ANY WORK BEGINS. THE CONTRACTOR

AutoCAD SHX Text

RECOMMENDATIONS. REVIEW CONSTRUCTION PLANS WITH THE OWNER OR

AutoCAD SHX Text

INSTALL PVC PIPE IN ACCORDANCE WITH MANUFACTURER'S

AutoCAD SHX Text

A. GENERAL

AutoCAD SHX Text

PIPING."

AutoCAD SHX Text

IRRIGATION PIPELINES."

AutoCAD SHX Text

APPLICABLE STANDARDS

AutoCAD SHX Text

AND TURF AND MULCH AREAS.

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

PIPE

AutoCAD SHX Text

PACKAGE.

AutoCAD SHX Text

SUBSTITUTIONS

AutoCAD SHX Text

ANY AVAILABLE EXISTING SLEEVES.

AutoCAD SHX Text

40, 80, AND 120.

AutoCAD SHX Text

ASTM D2774, "UNDERGROUND INSTALLATION OF THERMOPLASTIC PRESSURE

AutoCAD SHX Text

ASTM D1785, POLY (VINYL CHLORIDE) (PVC) PLASTIC PIPE, SCHEDULES

AutoCAD SHX Text

WHEREVER BRAND NAMES ARE USED IN THESE SPECIFICATIONS, USE ONLY

AutoCAD SHX Text

THE BRAND SPECIFIED. MAKE NO SUBSTITUTIONS AS A PART OF THIS BID

AutoCAD SHX Text

TRANSPORTATION, UNLESS OTHERWISE SPECIFIED, NECESSARY TO PROVIDE

AutoCAD SHX Text

AN AUTOMATIC IRRIGATION SYSTEM FOR LANDSCAPE PLANT MATERIALS

AutoCAD SHX Text

AMERICAN SOCIETY OF AGRICULTURAL ENGINEERS S376.1, "DESIGN,

AutoCAD SHX Text

INSTALLATION AND PERFORMANCE OF UNDERGROUND, THERMOPLASTIC

AutoCAD SHX Text

FURNISH ALL MATERIALS, LABOR, EQUIPMENT, TOOLS, AND

AutoCAD SHX Text

REPRESENTATIVE FOR THE LOCATION, DEPTH, NUMBER AND SIZE OF

AutoCAD SHX Text

FURNISH ALL UNDERGROUND PIPING AS PVC EXCEPT FOR THE FLEXIBLE

AutoCAD SHX Text

POLYETHYLENE (POLY PIPE) PIPING THAT IS TO BE USED BETWEEN THE

AutoCAD SHX Text

SIZE EACH SLEEVE TO ACCOMMODATE THE PIPES AND WIRES BEING

AutoCAD SHX Text

ROUTED THROUGH IT. CONSULT WITH THE OWNER OR OWNER'S

AutoCAD SHX Text

PART 2 - MATERIALS

AutoCAD SHX Text

PART 1 - GENERAL

AutoCAD SHX Text

LATERALS AND SPRINKLER HEADS. ALL MAIN LINE PVC PIPE SHALL BE

AutoCAD SHX Text

SCHEDULE 40 PVC AND ALL ZONE PIPE SHALL BE CL200 PVC OR BETTER.

AutoCAD SHX Text

INSPECT THE CONSTRUCTION SITE BEFORE ANY WORK BEGINS AND FLAG

AutoCAD SHX Text

FLAGGING HAS BEEN APPROVED.

AutoCAD SHX Text

DIAMETER, ROCKS, OR STONES.

AutoCAD SHX Text

TOP OF THE PIPE BEFORE THE TRENCH IS WHEEL-LOADED.

AutoCAD SHX Text

PIPE AND 12" OF COVER FOR ALL ZONE PIPE AS MEASURED FROM

AutoCAD SHX Text

PROVIDE FOR A MINIMUM DEPTH OF COVER OF 18'' FOR ALL MAIN LINE

AutoCAD SHX Text

COORDINATE THE INSTALLATION OF THE IRRIGATION SYSTEM WITH THE

AutoCAD SHX Text

THAT POINT. INSTALLATION SHALL NOT COMMENCE UNTIL THE STAKING/

AutoCAD SHX Text

PROVIDE INITIAL BACK FILL MATERIAL THAT IS FINE-GRAINED MATERIAL

AutoCAD SHX Text

FREE FROM COMPACTED EARTH GREATER THAN TWO INCHES IN

AutoCAD SHX Text

TAMP THE BACK FILL IN LAYERS NOT TO EXCEED SIX INCHES. LIFT AND

AutoCAD SHX Text

COMPACT FIRMLY AROUND THE PIPE AND UP TO AT LEAST SIX INCHES

AutoCAD SHX Text

LOCATIONS OF MAINLINE PIPE, SLEEVES, HEADS AND VALVES FOR REVIEW

AutoCAD SHX Text

FINISHED GRADE.

AutoCAD SHX Text

PIPE TRENCH CONSTRUCTION

AutoCAD SHX Text

BACK FILL

AutoCAD SHX Text

TO THE PLANT MATERIAL.

AutoCAD SHX Text

IF THERE IS ANY DOUBT AS TO HEAD LINE OR ZONE PLACEMENT.

AutoCAD SHX Text

FINISHED, THE SOIL COMPACTION EQUALS THE ORIGINAL CONDITION.

AutoCAD SHX Text

SOLVENT CEMENT AND PRIMER

AutoCAD SHX Text

WITH ASTM F656.

AutoCAD SHX Text

SEE DETAILS FOR SPRINKLER TO PIPE CONNECTIONS. NO ''FLEX PVC''

AutoCAD SHX Text

ACCORDANCE WITH ASTM D2564 AND PRIMER MANUFACTURED IN ACCORDANCE

AutoCAD SHX Text

USE A MEDIUM OR HEAVY BODY GRAY SOLVENT CEMENT MANUFACTURED IN

AutoCAD SHX Text

''TOE'' NIPPLE GLUED INTO A SCHEDULE 40 COUPLER.

AutoCAD SHX Text

DO NOT USE MALE ADAPTERS FOR ANY APPLICATIONS. INSTEAD, USE A

AutoCAD SHX Text

12454- B COMPOUND AND TESTED IN ACCORDANCE WITH ASTM D2467.

AutoCAD SHX Text

APPLICATIONS, USE SCHEDULE 80 FITTINGS MANUFACTURED FROM PVC

AutoCAD SHX Text

WITH ASTM D2466, EXCEPT FOR THREADED FITTINGS. FOR THREADED

AutoCAD SHX Text

MANUFACTURED FROM PVC 12454-B COMPOUND AND TESTED IN ACCORDANCE

AutoCAD SHX Text

FOR PVC ZONE PIPE, USE SCHEDULE 40, SOLVENT WELD FITTINGS,

AutoCAD SHX Text

AND USE THREADED FITTINGS FOR CONNECTION TO VALVES.

AutoCAD SHX Text

FOR MAIN LINE PVC PIPE FITTINGS, USE PVC SCH. 40 FITTINGS

AutoCAD SHX Text

PIPE FITTINGS

AutoCAD SHX Text

USE U.F. WIRE APPROVED FOR DIRECT BURIAL UNDERGROUND FOR ALL 24

AutoCAD SHX Text

PROVIDE THE MINIMUM DEPTH OF COVER, AS SPECIFIED ABOVE, OVER THE

AutoCAD SHX Text

LANDSCAPE CONTRACTOR TO PROVIDE FOR CORRECT APPLICATION OF WATER

AutoCAD SHX Text

BY THE LANDSCAPE ARCHITECT/OWNER. FLAGS SHALL BE CLEARLY MARKED

AutoCAD SHX Text

OR COLORED TO DESIGNATE THE TYPE OF EQUIPMENT TO BE INSTALLED AT

AutoCAD SHX Text

ABOVE THE TOP OF THE PIPE. SUFFICIENTLY MOISTEN THE BACK FILL TO

AutoCAD SHX Text

PERMIT THOROUGH COMPACTION UNDER AND ON EACH SIDE OF THE PIPE TO

AutoCAD SHX Text

PROVIDE SUPPORT FREE FROM VOIDS. AVOID DEFORMING, DISPLACING, OR

AutoCAD SHX Text

DAMAGING PIPE DURING THIS PHASE OF THE OPERATION. ASSURE THAT WHEN

AutoCAD SHX Text

SHALL CONTACT THE LANDSCAPE ARCHITECT/OWNER PRIOR TO INSTALLATION

AutoCAD SHX Text

VALVE BOXES

AutoCAD SHX Text

USE 12 X 18 VALVE BOXES FOR ALL APPLICATIONS.

AutoCAD SHX Text

DRIP TUBING

AutoCAD SHX Text

INSTALL HUNTER HDL-COP .9 GPH, 12'' O.C. TUBING FOR ALL DRIP LINE APPLICATIONS.

AutoCAD SHX Text

DRIP TUBING FITTINGS

AutoCAD SHX Text

INSTALL HUNTER TUBING FITTINGS FOR ALL DRIP LINE APPLICATIONS.

AutoCAD SHX Text

SPRINKLERS

AutoCAD SHX Text INSTALL HUNTER PROS-06-PRS40 SPRINKLERS WITH APPROPRIATE SCREENS AND NOZZLES FOR ALL TURF SPRAY HEAD APPLICATIONS. INSTALL HUNTER PROS-06-PRS30 SPRINKLERS WITH 5Q NOZZLES FOR ALL TREE SPRAY HEAD APPLICATIONS.

AutoCAD SHX Text

POINT OF CONNECTION

AutoCAD SHX Text CONNECT TO THE THE POTABLE BFP STUBOUT CAPABLE OF 26.3 GPM AT 50 PSI. NOTIFY THE LANDSCAPE ARCHITECT OF ANY DISCREPANCIES AS TO GALLONAGE AND PRESSURE BEFORE COMMENCING WITH THE INSTALLATION.

AutoCAD SHX Text

GOVERNING REGULATIONS

AutoCAD SHX Text

INSTALL THE IRRIGATION SYSTEM IN ACCORDANCE WITH LOCAL CURRENT IRRIGATION

AutoCAD SHX Text

REGULATIONS AND REQUIREMENTS.

AutoCAD SHX Text WATER STAR INSTALLATION REQUIREMENTS INSTALLATION REQUIREMENTS ASSURE THAT THE SYSTEM IS INSTALLED WITHIN THE FOLLOWING PARAMETERS: GENERAL IRRIGATION ZONES FOR TURF GRASS AND LANDSCAPE BEDS ARE SEPARATE. SPRINKLERS AND EMITTERS ARE LOCATED A MINIMUM OF 2 FEET FROM STRUCTURES. STRUCTURES. STRUCTURES. IRRIGATION SYSTEM IS FREE FROM LEAKS. SPRINKLERS IN LOW-LYING AREAS HAVE CHECK VALVES. SPRINKLERS RISE ABOVE TURF GRASS HEIGHT. APPLICATION OCCURS IN CORRECT SPRAY PATTERNS, MINIMIZING OVERSPRAY ON IMPERVIOUS SURFACES. UNIFORMITY PIPES ARE SIZED TO PREVENT VELOCITIES GREATER THAN 5 FEET PER SECOND. PRECIPITATION RATES FOR ALL SPRINKLERS WITHIN A ZONE ARE MATCHED. HEAD SPACING DOES NOT EXCEED 50% OF THE NOZZLE THROW DIAMETER. ALL ZONES ARE PRESSURE REGULATED AT THE MANUFACTURER’S SPECIFIED PRESSURE S SPECIFIED PRESSURE FOR THE SPRINKLERS/EMITTERS INSTALLED WITHIN THE ZONE. E. VARIABLE-ARC NOZZLES (VANS) ARE ONLY USED TO IRRIGATE UNEVENLY SHAPED TURF GRASS AREAS THAT CANNOT BE EFFECTIVELY IRRIGATED WITH FIXED-SPRAY NOZZLES. CANNOT BE EFFECTIVELY IRRIGATED WITH FIXED-SPRAY NOZZLES. CANNOT BE EFFECTIVELY IRRIGATED WITH FIXED-SPRAY NOZZLES. OPERATION AND SCHEDULING A DEVICE WITH RAIN SHUT-OFF CAPABILITIES IS INSTALLED IN AN OPERABLE LOCATION AND IS FUNCTIONING. . THE IRRIGATION SCHEDULE FOR MAINTENANCE DOES NOT EXCEED 25 INCHES (15.5 GALLONS) PER SQUARE FOOT ANNUALLY, AND THE CONTROLLER IS SET IN COMPLIANCE WITH WATER MANAGEMENT DISTRICT WATERING RESTRICTIONS. WATERING RESTRICTIONS. WATERING RESTRICTIONS. WATER BUDGET COMPLIANCE CONTRACTOR TO PROVIDE THE OWNER WITH A WATER BUDGET COMPLIANCE REPORT. IT IS A WATER BUDGET COMPLIANCE REPORT. IT IS IT IS IT IS RECOMMENDED THAT THE FLORIDA WATER STAR SM WATER BUDGET CALCULATOR BE USED. FOR MORE INFORMATION, SEE THE FLORIDA WATER STAR SM TECHNICAL MANUAL WEB INFORMATION, SEE THE FLORIDA WATER STAR SM TECHNICAL MANUAL WEB INFORMATION, SEE THE FLORIDA WATER STAR SM TECHNICAL MANUAL WEB PAGES.

AutoCAD SHX Text

GROUNDING

AutoCAD SHX Text

GROUND THE CONTROLLER LOCATION IN ACCORDANCE WITH THE DETAIL

AutoCAD SHX Text

AND THE MANUFACTURER'S RECOMMENDATIONS.

AutoCAD SHX Text INSTALL ELECTRIC VALVES PER THE LEGEND WITH PRESSURE REGULATORS FOR ALL APPLICATIONS. INSTALL FILTRATION ON ALL DRIP ZONE VALVES.

USE A CONTROLLER PER LEGEND AND NOTES. ASSURE THAT THE SYSTEM IS INTERFACED WITH A HUNTER WSS-SEN SENSOR FOR THIS SYSTEM.

6 Sprinkler Installation NTS 6'' Pop-Up Sprinklers

3 5

NOTES:

1. COMPACT SOIL AROUND POP-UP HEAD TO 95% OF SURROUNDING SOIL DENSITY.

2. INSTALL POP-UP HEAD PERPENDICULAR AND FLUSH TO FINISHED GRADE.

3. PLACE POP-UP HEAD MINIMUM 6-INCHES OFF TREE ROOT BALL.

FINISHED GRADE / TOP OF

MULCH.

SPRAY BODY. SET IN CLEAN

SOIL WITH NO ROCKS OR

DEBRIS IN CONTACT WITH

SPRINKLER BODY.

PVC LATERAL PIPE. SEE

LEGEND/SPECIFICATIONS

FOR TYPE.

SWING PIPE ASSEMBLY;

SA-125050.

PVC SERVICE TEE, SEE

SPECIFICATIONS FOR TYPE.

NOZZLE PER LEGEND. SEE

PLAN FOR NOZZLE BRAND

AND TYPE.

SPRAY HEAD INSTALLATION

WIPER SEAL7

7 WALL MOUNT CONTROLLER

NTS

PIPE TRENCH DETAIL

NTS

NOTE;

1. MINIMUM PIPE DEPTH SHALL BE PER DETAIL / LOCAL / STATE CODES, FROSTLINE, WITCH

EVER IS MOST STRINGENT.

2. MAINLINE AND LATERAL PIPE, TYPE AND DEPTH UNLESS OTHERWISE NOTED IN

SPECIFICATIONS.

3. PIPE IN THE SAME TRENCH SHALL HAVE MINIMUM 6" HORIZONTAL & VERTICAL SEPARATION.

4. IF ROCK OR OTHER DEBRIS IS ENCOUNTERED, CONTRACTOR SHALL SHALL HAVE MINIMUM

IMBED PIPE 3/4"-2" IN 4" OF SAND, AND 3"- 4" IN 6" OF SAND. FOR LARGER PIPE. SEE

SPECIFICATIONS

5. COMPACT BACKFILL TO 95% DENSITY.

6. CONTRACTOR TO REPAIR ALL SINK HOLES AND DEPRESSIONS UNDER WARRANTY PERIOD AT

NO COST TO OWNER.

7. LATERAL PIPE IN R.O.W. SHALL HAVE MINIMUM 18" COVER.

MAINLINE

PIPE

LATERAL

PIPE

WIRE CONDUIT IN

SEPARATE TRENCH

MAINLINE, LATERAL,

AND WIRE CONDUIT

IN THE SAME TRENCH

24"-36" 12"-18"

24"-36"

12"-18" 18"

6" BETWEEN PIPES SNAKE PIPE IN TRENCH 12-INCHES

FOR EVERY 100 FEET.

PLAIN VIEW

CONTROLLER GROUNDING DETAIL

NTS

30" MIN. *

18"

12"

8'

8'

15' MIN.

9'

9'

C

ELECTRODE

SPHERE OF

INFLUENCE

BOUNDARIES

TOP VIEW

SIDE VIEW

IRRIGATED LANDSCAPE AREA1

2 CONTROLLER MOUNTED ON

DUMPSTER ENCLOSURE WALL

CONCRETE PAD3

1.5" SCH-40 PVC SWEEP ELL4

6 AWG SOLID BARE COPPER WIRES.

CONNECTED DIRECTLY TO CONTROLLER

GRD BAR.

COPPER GROUND PLATE (4'' x 96'' x .0625")

WITH MINIMUM 50 LB GROUND

ENHANCEMENT MATERIAL (PAIGE).

SPHERE OF INFLUENCE.7

5/8" x 8' COPPER CLAD GROUND

ROD.

CADWELD CONNECTION.9

NOTE;

1. DO NOT INSTALL ANY OTHER WIRE OR CABLE WITHIN THE SPHERE OF INFLUENCE.

2. INSTALL GROUNDING PLATE MINIMUM 30" BELOW FINISHED GRADE, OR BELOW

FROSTLINE, WHICHEVER IS DEEPER.

3. MEGGAR TEST GROUNDING GRID, MINIMUM 10 OHMS OR LESS REQUIRED,

CONTRACTOR TO PROVIDE ON HIS LETTER HEAD, TIME, DATE, AND TEST RESULT.

SUBMIT A COPY TO OWNER OR OWNERS REP. PRIOR TO FINAL WALK THROUGH

5 8

TREE SPRINKLER LOCATIONS

NOTES:

1. IF SCH-80 PVC FITTINGS ARE SPECIFIED FOR

MAINLINE, CONTRACTOR MAY USE SOLVENT

WELD FITTING…

This is the start of the file's text. The full file is on GovTribe.