Appendix 5 Elevator Dimensions.pdf
PDF 3 MB Posted
- Solicitation number
- FA700024Q0030
About this file
This document is an appendix that provides the elevator dimensions for a federal contract opportunity. The appendix specifies the capacity, height, width, depth, and entry door dimensions for the elevator system. It includes details on the transmittal form for submitting shop drawings, equipment data, material samples, or manufacturer's certificates of compliance. The elevator system must meet the requirements outlined in the contract documents.
The related federal contract opportunity is for the purchase, delivery, and installation of furniture for the Madera Cyber Innovation Center at the USAF Academy in Colorado. The solicitation is an open competition for responsible sources to submit quotes. The Department of the Air Force Headquarters Air Force Academy is the procuring agency, and a purchase order will be established with one quoter.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Appendix 5: Elevator specifica ons
Elevator Dimensions Summary
Capacity: 3500 LB
Height: 8’3”
Width: 6’8”
Depth: 5’5”
Entry Door: 8’ height by 3’6” wide (~8’7” diagonal)
For use of this form, see ER 415-1-0; the proponent agency is CECW-CE
TRANSMITTAL OF SHOP DRAWINGS, EQUIPMENT DATA, MATERIAL SAMPLES, OR
MANUFACTURER'S CERTIFICATES OF COMPLIANCE
U.S. Army Corps of Engineers (USACE) DATE
5/5/2023 14 24 23-1.4
TRANSMITTAL NO.
SECTION I - REQUEST FOR APPROVAL OF THE FOLLOWING ITEMS (This section will be initiated by the contractor)
CONTRACT NO.
W9128F20C0038
CHECK ONE:
THIS IS A NEW TRANSMITTAL
THIS IS A RESUBMITTAL OF
TRANSMITTAL 14 24 23-1.3
SPECIFICATION SEC. NO. (Covers only one section with each transmittal)
14 24 23-HYDRAULIC PASSENGER ELEVATOR
PROJECT TITLE AND LOCATION
FY18 DB CyberWorx,USAF Academy, CO
THIS TRANSMITTAL IS FOR: (Check one)
FIO GA X DA CR DA/CR DA/GA
TO:
Air Force Academy Resident Office 8110 Security Drive, Suite 7 U.S. Air Force Academy, CO 80840
FROM: Federal/Bryan 5475 Tech Center Drive, Suite 300 Colorado Springs CO 80919
USA
ITEM
NO. DESCRIPTION OF SUBMITTAL ITEM
SUBMITTAL
TYPE CODE
NO.
OF
COPIES
CONTRACT DOCUMENT
REFERENCE CONTRACTOR
REVIEW
CODE
VARIATION
USACE
ACTION
CODE
(See Note 3)
(Type size, model number/etc) (See Note 8)
SPEC.
PARA. NO.
DRAWING
SHEET NO.
Enter "Y" if requesting a variation
(See Note 6)
(Note 9)
a. b. c. d. e. f. g. h. i.
1 Elevator System 02 - SHOP 0 2.1 A No
The shop drawings have been corrected to match the contract documents.
REMARKS
NAME OF CONTRACTOR SIGNATURE OF CONTRACTOR
I certify that the above submitted items had been reviewed in detail and are correct and in strict conformance with the contract drawings and specifications except as otherwise stated.
ENCLOSURES RETURNED (List by Item No.) DATE
SECTION II - APPROVAL ACTION
NAME AND TITLE OF APPROVING AUTHORITY SIGNATURE OF APPROVING AUTHORITY
ENG FORM 4025, MAY 2017 Page 1 of 1PREVIOUS EDITIONS ARE OBSOLETE.
F
Digitally signed by tnapier@bryanconstruction.com Date: 2023.05.05 11:39:48 -06:00
Benjamin Alter, Contracting Officer's Representative Digitally signed by ALTER.BENJAMIN.DAVID.1154216010 Date: 2023.05.24 10:23:14 -06:00 Contracting Officer's Representative
PROJECT TITLE FY18 DB CyberWorx
LOCATION USAF Academy, CO
DATE
05/24/2023
TRANSMITTAL NO.
14 24 23-1.4
Item Description Variation QA Code
1 Elevator System No F
SECTION III - GOVERNMENT REVIEW REMARKS
No remarks
CONTRACT NO.
W9128F20C0038
PAGE
TRANSMITTAL OF SHOP DRAWINGS, EQUIPMENT DATA
MATERIAL SAMPLES, OR MANUFACTURER'S
CERTIFICATES OF COMPLIANCE
Attachment to ENG FORM 4025-R
***PLEASE USE THE SPACES BELOW FOR COMMENTS AND STAMPS***
Submittal Approval Sheet
BRYAN CONSTRUCTION INC.
Reviewed for general conformance with the contract documents.
Review of this submittal does not relieve the subcontractor/supplier of responsibility for full compliance with the plans, specifications and conditions of the contract documents. Dimensions, quantities, errors, omissions and the furnishing of all items required, whether shown in the submittal or not, shall remain the responsibility of the subcontractor/supplier.
Submittal No. Specification Number
Project No. Date:Reviewed By:
0001 26 05 33
11033 John Snyder 7/12/12
BRYAN CONSTRUCTION INC.
Reviewed for general conformance with the contract documents.
Review of this submittal does not relieve the subcontractor/supplier of responsibility for full compliance with the plans, specifications and conditions of the contract documents. Dimensions, quantities, errors, omissions and the furnishing of all items required, whether shown in the submittal or not, shall remain the responsibility of the subcontractor/supplier.
Submittal No. Specification Number
Project No. Date:Reviewed By:
BCI REVIEWER NOTES:
-Note all markings in GREEN on the submittals below.
-Unless noted otherwise, the comments by BCI are to be considered as "Make Corrections Noted" and the responsibility will belong to the subcontractor in making the correction or verification noted.
o NO EXCEPTIONS TAKEN o REVISE AND RESUBMIT o MAKE CORRECTIONS NOTED o SUBMIT SPECIFIED ITEM
Specification Section:
Item / Description jpatton Text Box The shop drawings have been corrected to match the contract documents.
mcollins Typewritten Text
For Project
AIR FORCE CYBERWORX
TKE Job Number: EGK997
Elevator: 1
Located at
USAF ACADEMY
COLORADO SPRINGS,CO 80840
Company (Mail To)
Bryan Construction 5475 Tech Center Drive, Ste 300
Colorado Springs, CO 80919
Phone:
Attention:
Brett Kmetz
Final Drawing
Approved
May 3, 2023
460 Volts A.C. 3 Phase 60 Cycles
THE FOLLOWING POWER INFORMATION HAS BEEN CONFIMED:
BUILDING POWER:
SUMMARY OF FINAL APPROVAL SECTIONS
ELEVATOR DESIGNATION:
FACTORY JOB NUMBER: EGK997
APPROVED CAB AND FIXTURE SELECTIONS
APPROVED ENTRANCE INFORMATION APPROVED POWER CONFIRMATION
MAIN EGRESS FLOOR (Fire Service):
FLOOR
MARKINGS WALL TYPE
WALL
THICKNESS (X)
ENTRANCE
DOOR FINISH
ENTRANCE
FRAME FINISH
ALTERNATE FLOOR (Fire Service):
FINAL DRAWINGS APPROVED
FEATURES FOR YOUR FIXTURES
SUBMITTAL MARKUP INSTRUCTION
REVISION HISTORY (CSC USE ONLY)
VOIDED/REFUSED MARKUP REQUESTS (CSC USE ONLY)
1. ALL MARKUPS SHOULD BE CLEAR, LEGIBLE, AND CONCISE.
2. ALL MARKUPS SHOULD CORRESPOND WITH MOST RECENT REVISION.
3. NOTE: ADDITIONAL MARKUPS SENT TO COORDINATOR DURING A REVISION CYCLE WILL NOT BE CONSIDERED. FIELD MUST WAIT UNTIL THE
REVISION IS COMPLETE AND PROVIDE MARKUPS ON THE MOST RECENT REVISION.
4. ALL MARKUPS SHOULD BE CIRCLED AND NUMBERED TO IDENTIFY THE CHANGE REQUEST.
5. ITEMS CIRCLED, HIGHLIGHTED, OR CROSSED THROUGH WITHOUT COMMENTS WILL NOT BE ADDRESSED.
6. REVISIONS TO THE SUBMITTALS WILL NOT PROCEED IF THE MARKUP STANDARD IS NOT FOLLOWED.
7. IF DOCUMENTS ARE REFERENCED ON THE MARKUPS, THE REFERENCED DOCS MUST BE INCLUDED IN THE RETURNED SUBMITTAL PACKAGE.
REVISION HISTORY CONT'D (CSC USE ONLY)
DRAWN DATE JOB NUMBER REV. SHEET NO.CHKD.
AIR FORCE CYBERWORX HMD 10/5/22 X EGK997 1 OF 1C
LAYOUT SUBMITTAL REVISION COVER SHEET
JOB NAME
ADDENDUM - CLARIFICATIONS NEEDED
1' -6
3" O
IL
IN
LE
T
1' -4
/2
AB
O
VE
P
IT
F
LO
O R
3' -6
7' -3
/2
" B
ET
W
EE
N R
AI
LS
6' -8
" C
LE
AR
IN
SI
D
E
1' -1
4' -9
" R O
U G
H O
PE
N
IN
G
8' -8
" C
LE
AR
H
O
IS
TW
AY
3' -6
S
1' -6
3' -6
" C
LE
AR
O
PN
G
3' -6
" C
LE
AR
O
PN
G
H
AL
L
ST
AT
IO
N W
FI
R E
SV
C
. S W
LC
BU
FF
ER
1/
2"
3/
4"
BU
FF
ER
LC
SWS.
C .S
= RAIL BRACKET MOUNTING SURFACE
7' -0
" P
LA
TF
O
R M
3'-7 3/4"
3'-1 1/2"
6'-3" PLATFORM
8'-0 1/2" TUBE STEEL TO TUBE STEEL
6 1/4"
5'-5" CLEAR INSIDE
1'-9 1/4"
PLATFORM
TO WALL
8" DEEP TUBE STEEL
BY OTHERS (TYP)
3' -3
" 4' -1
A
3' -5
/2
A
R =1
2, 3/
4" F
AC
E
O F
R
AI
L
3/
4"
5"
R
AI
L
LI
N E
A
R =1
2, R
AI
L
LI
N E
B
3"
AC
C
ES
S
SW
EACH OTHER ) CLEAR REQ'D. IN FRONT OF
ALL ELECTRICAL PANELS
NOTE: MIN. OF 3'-6" ( 4'-0" WHEN FACING
9' -1
20,132 BTU/HR
HEAT LOAD =
10'-9 1/2"
4'-0" X 8'-0"
DISC. SW. ABOVE CAR LIGHT, ALARM
CIRCUIT AND JCT. BOX
CIRCUIT W/DISC. SW. AND/OR PHONE
3' -6
" M
IN
ELEVATOR
NUMBER
MOTOR
HP.
RATED
AMPS
STARTING
AMPS
MAX. UP ACC.
AMPS (FULL
LOAD)
60 76.0 228 108
H L
,3 ,M
H L/
PI
MACHINE ROOM LOCATED ADJACENT TO HOISTWAY @ 1ST. FLOOR.
PLAN OF HOISTWAY & MACHINE ROOM
6'-2"
3' -3
/8
"9 1/2" AB. FLOOR
3" OIL LINE
SHEAVE SIDE
TANK HT. = 7'-3 1/2"C
O
N
TR
O
LL
ER
4'
-9
/4 " H
IG
H
3'-6" MIN.
2' -0
" M
IN
NOTE:
OIL COOLER REQUIRES A SEPARATE
120V, 1PH, 60 CYCLE, 20A CIRCUIT.
SU
M
P
PI
T
C O
VE
R
BY
O
TH
ER
S.
SCCR*
AMPS
10,000
*45 kA AND 600V OR LESS IF PROTECTED BY CLASS J FUSES SIZED
FOR THE APPLICATION ( CLASS J FUSE IS PROVIDED BY OTHERS.)
PIPE. ASTM A-53; TYPE E OR S
3" OIL LINE FROM TANK TO 3"
SHUTOFF VALVE. 3" SCH 40 BLK
GRADE B OR EQUIVALENT TO JACK.
C
3' -6
" M
IN
PR
IM
AR
Y
EQ
U
IP
. B
O X
NOTE:
PRIMARY EQUIP. BOX REQUIRES A SEPARATE
120V, 1PH, 60 CYCLE, 20A CIRCUIT.
9' -1
" W
AL
L
TO
W
AL
L
1/
2"
1/ 2"
DRY POWER UNIT
NOTE:
VERIFY OIL COOLER LOCATION.
9'-3 1/2" 1'-0" 6"
NOTE A: OIL PIPE LINES AND FITTINGS SHALL BE PROPERLY SUPPORTED TO RELIEVE STRAIN.
NOTE C: TK ELEVATOR TO BE NOTIFIED OF ANY CHANGE TO ELEVATOR
NOTE D: ELEVATOR DESIGN AND FABRICATION BASED ON ESTIMATED CAB WEIGHT SHOWN.
LAYOUT APPROVAL WILL BE CONSTRUED AS FINAL CAB WEIGHT, UNLESS
HOISTWAY OR MACHINE ROOM DESIGN.
OTHERWISE NOTIFIED.
NOTE B: ALL REACTIONS INCLUDE ALLOWANCE FOR IMPACT.
DATE SYM REVISION BY
REV
C
F2
IS PROVIDED, AN AUXILIARY CONTACT SHALL ALSO BE INSTALLED ON THE CIRCUIT BREAKER."
F2
RAIL FORCES F1F1
LBS.
1F 2F
LBS.
NOTE: MUST BE LOCATED AS DIRECTED BY ELEVATOR CONTRACTOR.
"IF STANDBY POWER TYPE 10D-0C IS PROVIDED, AN AUXILIARY CONTACT SHALL BE INSTALLED ON THE DISCONNECT SWITCH FOR EACH CAR. THE AUXILIARY CONTACT SHALL BE CONFIGURED AS SPST
PIPE SLEEVES, TRENCHING, AND BACK FILLING FOR OIL AND/OR CONDUIT LINES AS SHOWN
OR LOCATED BY ELEVATOR CONTRACTOR.
A SQUARE HOLE IN PIT FLOOR FOR SETTING OF JACK AND FILL WITH CONCRETE
CONDUIT AND WIRING FROM HOISTWAY TO ELEVATOR MONITORING PANELS (FOR SECURITY,
LIFE, SAFETY, OR FIRE REQUIREMENTS).
SMOKE SENSORS (AS REQUIRED).
WHEN THE DISCONNECT SWITCH IS IN THE OPEN POSITION. IF A SHUNT TRIP CIRCUIT BREAKER
AND BE RATED AT NO LESS THAN 1A AT 110 VAC. THE AUXILLARY CONTACT SHOULD BE OPEN
POCKETS IN CORRIDOR WALL (PER FIXTURE DRAWINGS) FOR HALL FIXTURES.
AFTER JACK IS SET.
14.
13.
10.
12.
11.
9.
INSTALLATION PROCEDURES FOR FRAME-TO-WALL INTERFACE DETAILS TO ENSURE CONFORMANCE
THE FOLLOWING CONDITIONS MUST BE MET BEFORE INSTALLATION
IS COMPLETED, AND ARE NOT INCLUDED IN THE ELEVATOR CONTRACT:
A PLUMB, PROPERLY-VENTILATED HOISTWAY (ACCORDING TO CODE AND SIZES SHOWN).
ENTRANCE WALL WITH LINTELS. NOTE: MUST BE PROVIDED AFTER ENTRANCE FRAMES ARE SET
- OR LEAVE A ROUGH OPENING 1'-3" WIDER AND 1'-3" HIGHER THAN THE FRAME OPENING. SEE
SEPERATE 120 VOLT, 15 AMP BRANCH CIRCUITS, ALONG W/ TELEPHONE CIRCUIT TO TERMINALS OF EACH REQ'D CONTROLLER FOR EACH OF THE FOLLOWING: 1) CAR LIGHT AND ALARM CIRCUIT
CAR (ACCORDING TO CODE). NOTE: MUST BE CLEAR OF ALL ELEVATOR EQUIPMENT.
PIT LIGHTS AND SWITCH, CONVENIENCE OUTLETS (GFCI TYPR PER NEC), 1 PIT LADDER PER
HOISTWAY BARRICADES (ALL CUTTING AND PATCHING TO INSTALL HOISTWAY ENTRANCES, SILLS, ADEQUATE SUPPORT FOR JACK, GUIDE RAIL BRACKETS, AND BUFFERS (FOR REACTIONS SHOWN).
AND HALL FIXTURES).
BRANCH-CIRCUIT CONDUCTOR SIZING, MATERIALS, AND INSULATION (INCLUDING BRANCH-CIRCUIT
W/ GFCI TYPE RECEPTACLES PER NEC. 2) GROUP CONTROL AS REQ'D. NOTE: IF STANDBY POWER
OVERCURRENT PROTECTIVE DEVICE) TO COMPLY WITH ALL LOCAL ELECTRICAL CODES (SEE
IS SUPPLIED, GROUP CONTROL CIRCUIT MUST BE STANDBY POWER BACKED.
"ELECTRICAL POWER REQUIREMENTS").
LEAVE WALL OUT UNTIL EQUIPMENT IS IN PLACE.
AN ENCLOSED MACHINE AREA (ACCORDING TO CODE), WITH ADEQUATE LIGHT, HEAT, AND
NOTE: MUST PROVIDE ADEQUATE DOOR SIZE TO ALLOW INSTALLATION OF EQUIPMENT - OR
VENTILATION (MIN. 50°F., MAX. 90°F. WITH NON-CONDENSING HUMIDITY OF 10-90%), AND
NOTE: IF STANDBY POWER IS REQUIRED, SEE "ELEVATOR STANDBY POWER OPERATION".
8.
7.
6.
5.
4.
3.
2.
1.
HYDRAULIC ELEVATOR CONTRACT DATA
CLEARANCE BET. PIT FL. AND CAR BOLSTER ON COMP'D BUFFERS
BUFFER TYPE SPRING BUFFER STROKE
MAX. LTH. OF ANY ONE PC. SECTION OF JACK PLGR. OR CYLINDER NOT TO EXCEED
IN.
PLUNGER O.D.
EST. WORKING PRESSURE
CYLINDER WALL THICKNESS
PLUNGER NET AREA
PLUNGER WALL TH'K'S.
CYLINDER O.D.
CYLINDER CPLG.
ELEVATOR NUMBER
SPEED DOWN FULL LOAD
POWER UNIT
JACK MODEL
MOTOR
STOPS
SPEED UP
MAX. AXLE LOAD
MAX. SUSTAINING LOAD
MAX. UNIT LOAD
OPERATION
CAPACITY
TYPE
BOTTOM RUNBYIN. IN.
TOTAL CAR WT. WITH
EST. CAB WT. W/O DOOR OPERATOR
LBS.
POWER UNIT WT. ( INCL. OIL WT.)
PIT CHANNELS
PLUNGER WT.
P.S.I.
REQ'D.
IN.
SQ. IN.
IN.
IN.
O.D.
LBS.
IN.
LBS.
LBS.
LG.
POWER SUPPLY V. 3 PH. CY.
CAR GUIDE RAILS
TOP OVERTRAVEL
BOTTOM OVERTRAVEL
HOISTWAY ENTRANCES
CAR DOOR
BALANCE WT. FILLERS
PLATFORM FL. TH'K'S.
BOLSTER
CROSSHEAD
GUIDE TYPE
CAR ENCLOSURE
-S
HP
F.P.M.
F.P.M.
LBS.
LBS.
LBS.
LBS.
STILE
IN.
IN.
LBS.
IN.
SEALED CONCRETE FLOOR SLAB SURFACE.
WITH THE LABELED ENTRANCE INTERFACE CONSTRUCTION.
NOTE: ALSO, A FOURTH WIRE TO SAME SIZE AS THREE PHASE WIRES IS REQUIRED FOR
GROUNDING PURPOSES TO MINIMIZE ELECTRICAL NOISE INTERFERENCE. THE GROUNDING WIRE
MUST BE CONNECTED TO THE BUILDINGS ELECTRICAL SYSTEM GROUND.
PASSENGER CLASS A
TAC32
AP-350
7.488 0.362 44.032 10 3/4 1/4
12 1
480 60 F6 X 6.26 F6 X 5.70 F8 X 7.68
4 1/8
APPLIED PANEL
4" ROLLER
15# TEE
SINGLE SPEED
SINGLE SPEED
C7 X 9.8 X 4'-10 1/2"
52'-8"
2 1/2 2'-3 3/8"
2'-6"
470 330
DRAWN DATE
GENERAL CONTRACTOR:
ARCHITECT:
CITY:
ADDRESS:
ELEVATOR CONTRACTOR:
FOR:
JOB NUMBERCKD
OF
SHEET NO
CONTRACT NUMBER
THIS DRAWING AND ALL INFORMATION THEREON IS THE PROPRIETARY PROPERTY OF TK ELEVATOR, AND MUST NOT BE MADE PUBLIC OR COPIED. THIS DRAWING IS LOANED SUBJECT TO RETURN ON DEMAND AND IS NOT TO BE USED, DIRECTLY OR INDIRECTLY, IN ANY MANNER DETRIMENTAL TO THE INTEREST OF TK ELEVATOR.
HMD 10/5/22 EGK997
AIR FORCE CYBERWORX
USAFA
COLORADO SPRINGS, 80804
CLARKNEXSEN
BRYAN CONSTRUCTION
TK ELEVATOR
DENVER, CO
1 2
Shaft Wall
Tube Steel
49'-7" NET TRAVEL13'-3" MIN. CLEAR OVERHEAD
9'-3" TOP OF CAB IN FULL TOP
OVERTRAVEL w/ 8'-10" O.A. CAB HT.
9'-7"
10'-0" UNDER CROSSHEAD
4'-0" MIN.
(REFUGE SPACE)
2"
M
EZ
ZA
N
IN
E
EL
. 4
9' '-7
4'-0" PIT
2'-1 1/2"
JACK SETTING
53'-9 7/16"
BOTTOM LANDING TO BOTTOM OF JACK
1'-5"
10'-7"
9'-3" ROUGH OPNG. TYP.
8'-0" CLEAR OPNG. TYP.
1S T
FL
O
O R
EL
. 0
'-0
BRACKET (TYP.)
51'-7 15/16"
CYLINDER LENGTH
PLUNGER LENGTH
= 51'-3 516"
R = 22,392 LBS.
D
ES
IG
N
L O
AD
,2
L
BS
(S
TA
TI
C , N
O T
IM
PA
C T)
D
IR
EC
TE
D B
Y
TK
E
LE
VA
TO
R F
IE
LD
O
FF
IC
E
PR
O
VI
D
ED
IN
ST
AL
LE
D B
Y O
TH
ER
S, A
S R
EM
O
VA
BL
E
SA
FE
TY
B
EA
M R
EQ
'D
. P
ER
O
SH
A
.5
3' -7
/4
SECTION A-A
MAXIMUM ALLOWABLE BRACKET SPAN = 15'-9"
9'-7"
DIA. = 14"
HDPE CASING
17'-0"
4"
2N D
F
LO
O R
EL
. 1
7' -0
9'-7"
3R D
F
LO
O R
EL
. 3
9' -0
22'-0"
16'-0" RAIL16'-0" RAIL16'-0" RAIL8'-0" RAIL10'-8" RAIL
TOTAL JACK WT.
= 3567 LBS
NOTE:
TWO SECTION JACK SHIPPED
ASSEMBLED.
4"4"
SYMDATE REVISION BY
REV.
CDO NOT SCALE THIS DRAWING
DATE CAD SHEET NO.JOB NUMBER
OF
FOR:
THIS DRAWING AND ALL INFORMATION THEREON IS THE PROPRIETARY PROPERTY OF TK ELEVATOR AND MUST NOT BE MADE PUBLIC OR COPIED. THIS DRAWING IS LOANED SUBJECT TO RETURN ON DEMAND AND IS NOT TO BE USED, DIRECTLY OR INDIRECTLY, IN ANY MANNER DETRIMENTAL TO THE
INTEREST OF TK ELEVATOR.
10/5/22 HMD EGK997
AIR FORCE CYBERWORX
2 2
SUBMITTAL MARKUP INSTRUCTION
REVISION HISTORY (CSC USE ONLY)
1. ALL MARKUPS SHOULD BE CLEAR, LEGIBLE, AND CONCISE.
2. ALL MARKUPS SHOULD CORRESPOND WITH MOST RECENT REVISION.
3. NOTE: ADDITIONAL MARKUPS SENT TO COORDINATOR DURING A REVISION CYCLE WILL NOT BE CONSIDERED. FIELD MUST WAIT UNTIL THE
REVISION IS COMPLETE AND PROVIDE MARKUPS ON THE MOST RECENT REVISION.
4. ALL MARKUPS SHOULD BE CIRCLED AND NUMBERED TO IDENTIFY THE CHANGE REQUEST.
5. ITEMS CIRCLED, HIGHLIGHTED, OR CROSSED THROUGH WITHOUT COMMENTS WILL NOT BE ADDRESSED.
6. REVISIONS TO THE SUBMITTALS WILL NOT PROCEED IF THE MARKUP STANDARD IS NOT FOLLOWED.
7. IF DOCUMENTS ARE REFERENCED ON THE MARKUPS, THE REFERENCED DOCS MUST BE INCLUDED IN THE RETURNED SUBMITTAL PACKAGE.
DRAWN DATE JOB NUMBER REV. SHEET NO.CHKD.
AIR FORCE CYBERWORX JM 10/6/22 JM EGK997 1 OF 1C
ARCHITECTURAL SUBMITTAL REVISION COVER SHEET
JOB NAME
REVISION HISTORY (CSC USE ONLY)
VOIDED/REFUSED MARKUP REQUESTS (CSC USE ONLY)
ADDENDUM - CLARIFICATIONS NEEDED
ENTRANCE
REV.JOB NUMBERBY DATE BRANCH DRAWING NO.
OF
SHEET NO.
This drawing and all information thereon is the proprietary property of TK Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and is not to be used directly or indirectly in any manner detrimental to the interest of TK Elevator.
ELEVATOR CONTRACTOR:
ARCHITECT:
GENERAL CONTRACTOR:
CITY:
ADDRESS:
FOR:
BYREVISIONREV.DATE
DO NOT SCALE THIS DRAWING
ELEV #
NOTES
RAISED DOOR
JAMB SYMBOLS
D O
O R
"B" + 3 1/2"
5"
MIN.
FINISHED
SILL LINE
WALL
LINE
3/4"
8"
SECTION
1 7/8"
1/4" DOOR
TO FRAME
1 3/16" DOOR
2 1/16" DOOR
TO SILL
1/8"
EGK997
AIR FORCE CYBERWORX
USAF ACADEMY
COLORADO SPRINGS, CO 80840-
TKE DENVER
DENVER, CO
JM 10/06/22
JM1 1 1EGK997E1
EGK997ASAP
DESIGNED PER ASME A17.1
STAINLESS STEEL
TO BE 316 SERIES
M721 SILL SUPPORT
BY TKE
16 GA.
16 GA.
" C
/L
.1 0.
C
FR
P ar t 3
8' -0
" C
LE
AR
(F
R
AM
E) O
PE
N
IN
G
8' -2
" O
VE
R
AL
L
FR
AM
E
H
EI
G H
T 9'
-7
/4 " M
IN
IM
U M
F
LO
O R
T O
F
LO
O R
H
EI
G H
T
2"
THIS FRAME HAS A 2 HOUR WARNOCK HERSEY LABEL.
GC NOTE:
GENERAL CONTRACTOR RESPONSIBLE FOR HOISTWAY REINFORCING
AT FLOOR SLAB BEFORE INSTALLATION OF ENTRANCE FRAMES.
MINIMUM OF 4" HIGH x 8" WIDE REINFORCED CONCRETE, REINFORCED
FILLED BLOCK, WOOD OR STEEL BEAMS AT THE WALL LINE ON EACH SIDE
OF OPENING REQUIRED FOR ANCHORING SILL SUPPORT ASSEMBLY.
REINFORCING TO BE LOCATED WITH RESPECT TO REACTION POINTS.
REFERENCE INSTALLATION DRAWINGS 494JT, AND 494JV
ARE AVAILABLE UPON REQUEST.
REACTIONS (LBS.) DUE TO LOADS ON DOOR PANELS. APPROX. HORIZ.
LOADS AND LOCATIONS TO BUILDING SHOWN PER ASME A17.1, PART II.
THE SPECIFIED LOADS ARE CONSIDERED IMPACTED.
WALL TYPE FRAME FINISH DOOR FINISH
OVERALL
FRAME
"B" DIM.
FRONT REARFRONT REAR ACTUAL FRONT REAR FRONT REARACTUAL
FLOOR OPENINGS AT
FRONT REAR
(QTY) (QTY)
WALL SIZE (FRONT) WALL SIZE (REAR) SILL TYPE
FRONT REAR
WHEEL LOAD
FRONT REAR
MISC.
FRONT REAR
OVERALL
FRAME
"B" DIM.
1-3,M DRYWALL 4 1/8" 6 3/8" 4 #4 STLS #4 STLS NICKEL 625 WELDED FRAMES, 16 GA DOORS
ROUGH OPENING
3 7/16"SILL LINE
DRYWALL TYPE FRAME
FACE FACE
5"
MIN.
3/4"
3 1/2"
"B"
1/16"
4 1/2"
R22" BELOW
EACH FLOOR
R1
(LBS.)
REACTIONS
R2 R1
ENTRANCE ELEVATION
INTERLOCK
KEYHOLE
ROUGH OPENING
9' -3
" R O
U G
H O
PE
N
IN
G
H
EI
G H
T
4'-9" ROUGH OPENING WIDTH
ONE SPEED LEFT HAND DOOR & ENTRANCE
ELEVATOR 1 (FRONT)
2" 2"3'-6" CLEAR OPENING
3'-6"3'-6"
9' -3
" R O
U G
H O
PE
N
IN
G
H
EI
G H
T
TOTAL WEIGHT OF CAR
& HALL DOOR = 443 LBS.
C
FINAL
GRAIN TO RUN THE LENGTH
OF THE PART UNLESS OTHERWISE NOTED
FOR: ELEV #
DRAWING NO. REV.DATE BRANCH
OF
DWN JOB NUMBER SHEET NO.
DATE
CITY:
ADDRESS:
GENERAL CONTRACTOR:
ELEVATOR CONTRACTOR:
DO NOT SCALE THIS DRAWING
BYSYM. REVISION
ARCHITECT:
CAB
This drawing and all information thereon is the proprietary property of TK Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and is not to be used directly or indirectly in any manner detrimental to the interest of TK Elevator.
NOTES
LAMINATE BACKING SHEETS. APPLIED PANELS ARE FACED
AND WRAPPED ON VERTICAL EDGES WITH
14 GAUGE #4 STAINLESS STEEL WALLS. REMOVABLE APPLIED
PANELS HAVE 3/4" PARTICLE BOARD CORES WITH 1/32"
CAB WALLS
14 GAUGE STEEL TOP, REINFORCED TO COMPLY WITH ASME A17.1
CODE. THE EXTERIOR IS PRIMED AND THE INTERIOR IS PAINTED
CAB TOP
WITH DOWN LIGHT RECEPTACLES AS REQUIRED.
THE DOWN LIGHT CEILING CONSISTS OF FORMED
SUSPENDED CEILING
LED
LIGHTING
FRONT RETURN AND TRANSOM
FOR DOOR OPERATOR. INTERIOR IS
16 GAUGE HOLLOW METAL REINFORCED AND DRILLED
CAB DOORS
CAB BASE
HANDRAILS
FAN
TOP EMERGENCY EXIT PROVIDED WITH CARTOP EXIT SWITCH.
EMERGENCY EXIT
PROTECTION PADS
PAD BUTTONS
CAB SILL
CAB FLOORING
/2 " S
TL
. P
AN
EL
" S
TL
. P
AN
EL
/2 " C
LE
AR
IN
SI
D E
ST
EE
L
SH
EL
L
" P
LA
TF
O R
M
3/
8"
1/ 8"
2"
2 1/2"
3/
1 1/2" 1 1/2"81" CLEAR INSIDE STEEL SHELL
84" PLATFORM
40 3/4" STL. PANEL
2" 2 1/8"24 1/4"
43 1/4" STL. PANEL
REMOVABLE APPLIED PANEL CAB DESIGN
SEE DETAIL "A"
SEE DETAIL "B"
DENVER, CO
JM1
EGK997
DESIGNED PER ASME A17.1
#4 STAINLESS STEEL
F-114 REFLECTIVE WHITE.
STAINLESS STEEL #4 PAN SECTIONS
COLUMN TYPE SWING.
STAINLESS STEEL W/ #4 BRUSH FINISH
STAINLESS STEEL W/ #4 BRUSH FINISH.
STAINLESS STEEL W/ #4 BRUSH FINISH
1/4" X 2" STAINLESS STEEL #4 REMOVABLE CONTINUOUS BAR.
TWO SPEED EXHAUST WITH STANDARD FAN GRILL.
PROTECTION PADS TO BE SUPPLIED.
PAD BUTTONS TO BE SUPPLIED.
EXTRUDED NICKEL SILVER.
FLOORING BY OTHERS.
10/06/22JM
EGK997Field
CBK9971 1 4
AIR FORCE CYBERWORX
STAINLESS STEEL
TO BE 316 SERIES
USAF ACADEMY
TKE DENVER
COLORADO SPRINGS, CO 80840-
TWO WAY COMMUNICATION (2019)
2 WAY COMMMUNICATION CAMERA. THIS IS ONE WAY STREAMING ONLY - TO BE FIELD MOUNTED
22 1/4" 1 1/2"
3 1/8"
12 1/8"3" 42" CLEAR OPENING
SWING RETURN
ONE SPEED LEFT HAND DOOR AT FRONT
C
FINAL
GRAIN TO RUN THE LENGTH
1 LAYER SOUND DEADENING SHEETS TO BE PROVIDED
OF
DWN JOB NUMBER SHEET NO.
DATE
CITY:
ADDRESS:
GENERAL CONTRACTOR:
ELEVATOR CONTRACTOR:
DO NOT SCALE THIS DRAWING
BYSYM. REVISION
ARCHITECT:
CAB
This drawing and all information thereon is the proprietary property of TK Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and is not to be used directly or indirectly in any manner detrimental to the interest of TK Elevator.5 1/2"
B
B
ELEVATION 2 & 4
RIGHT SIDE SHOWN
LEFT SIDE OPPOSITE
1/
8"
1 1/8" PANEL
7/8" PANEL
3/
8"
SECTION B-B
A
A
ELEVATION 1
C
C
ELEVATION 3
1 1/2" TYP. AT FRONT AND REAR
1 1/8" PANEL
7/8" PANEL
3/ 8"
F
IN
IS
H
ED
F
LO
O
R (T
YP
SECTION C-C
" T
O T
O P
O F
H
AN
D R
AI
L
1 1/2" TYP. AT SIDES
SE
E
D
ET
AI
L
"C
SE
E
D
ET
AI
L
"D
SE
E
D
ET
AI
L
"E
1"
PA
D
B U
TT
O
N 1"
PA
D
B U
TT
O
N
DENVER, CO
JM1
EGK997
DESIGNED PER ASME A17.1
/2 " A
PP
LI
ED
P
AN
EL
S
/8 " U
N D
ER
S
U
SP
EN
D
ED
C
EI
LI
N G
5/ 8"
T O
P O
F
SI
D E
W
AL
LS
5/ 8"
O
VE
R
AL
L R
EA
R
W
AL
LS
VENTILATION AS REQUIRED PER ASME A17.1 CODE
(SEE DETAIL F)
10/06/22JM
EGK997Field
CBK9972 2 4
AIR FORCE CYBERWORX
STAINLESS STEEL
TO BE 316 SERIES
USAF ACADEMY
TKE DENVER
COLORADO SPRINGS, CO 80840-
SWING
RETURN
SECTION A-A
1/ 4"
2 1/4"
1 1/4"
1/4"
4 5/8"
3/ 4"
3/ 8"
F
IN
IS
H
ED
F
LO
O
R (T
YP
5/ 8"
U N
D
ER
T O
P
/8 " U
N D
ER
S
U
SP
EN
D
ED
C
EI
LI
N G
1/
4"
C
LE
AR
O
PE
N
IN
G
C
FINAL
OF
DWN JOB NUMBER SHEET NO.
DATE
CITY:
ADDRESS:
GENERAL CONTRACTOR:
ELEVATOR CONTRACTOR:
DO NOT SCALE THIS DRAWING
BYSYM. REVISION
ARCHITECT:
CAB
This drawing and all information thereon is the proprietary property of TK Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and is not to be used directly or indirectly in any manner detrimental to the interest of TK Elevator.
81" CLEAR INSIDE STEEL SHELL
EMERGENCY EXIT
CEILING (REFLECTED VIEW)
CARTOP (REFLECTED VIEW)
/2 " O
.A . D
EP
TH
(C
LE
AR
IN
SI
D
E
ST
EE
L
SH
EL
L)
7/8"
82 3/4" O.A. WIDTH
7/8" 78" O.A. WIDTH
/2 " O
.A . D
EP
TH
DENVER, CO
JM1
EGK997
DESIGNED PER ASME A17.1
10/06/22JM
EGK997Field
CBK9973 3 4
AIR FORCE CYBERWORX
STAINLESS STEEL
TO BE 316 SERIES
USAF ACADEMY
TKE DENVER
COLORADO SPRINGS, CO 80840-
FAN GRILL
C
FINAL
OF
DWN JOB NUMBER SHEET NO.
DATE
CITY:
ADDRESS:
GENERAL CONTRACTOR:
ELEVATOR CONTRACTOR:
DO NOT SCALE THIS DRAWING
BYSYM. REVISION
ARCHITECT:
CAB
This drawing and all information thereon is the proprietary property of TK Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and is not to be used directly or indirectly in any manner detrimental to the interest of TK Elevator.
1 1/8"
1 1/8"
2 1/2"
2 1/2" AT
FRONT AND
REAR
7/8"
PLATFORM EDGE
DETAIL "A"
(TYP. CORNER)
PL
AT
FO
R
M E
D G
E
2" TYP.
ALL CENTERS
(TYP. PANEL JOINT)
DETAIL "B"
3/8" FINISHED FLOOR
5 1/8"
(TYP. FLOOR MTG. DETAIL)
DETAIL "C"
REMOVABLE PANEL
PANEL CLIP
STEEL
SHELL
SUB-FLOOR LINE
3/4" WOOD CORE
1/32" BACKING SHEET
1/32" BACKING SHEET
1/32" FACE SHEET
DETAIL "D"
(TYP. HANDRAIL AND ATTACHMENT)
HANDRAIL FINISH
HANDRAIL, SPACER AND WASHER
#4 STAINLESS STEEL
SEE PAGE 2 FOR
HEIGHT ABOVE FLOOR
1"
1 3/8"
1 1/2" TYP.
DOWNLIGHT
CEILING
DETAIL "E"
(TYP. CEILING MOUNTING)
SIDE WALL
MOUNTING ON SIDE
WALLS ONLY
.563
3" 1 1/2"
3 3/16" 1/4"
(TYP.)
1/4"
(TYP.)
C 7 3/16"
13 1/4"
14 3/8"
(TYP. VENT DETAIL)
DETAIL "F"
L 1/4" x 3" SLOTS
(27 TOTAL)
UNFINISHED FLOOR
Ø7/32"
(2 HOLES)
COLORADO SPRINGS, CO 80840-
DENVER, CO
JM1
EGK997
DESIGNED PER ASME A17.1
10/06/22JM
EGK997Field
CBK9974 4 4
AIR FORCE CYBERWORX
STAINLESS STEEL
TO BE 316 SERIES
USAF ACADEMY
TKE DENVER
B
FINAL
GRAIN TO RUN THE LENGTH
OF THE PART UNLESS OTHERWISE NOTED
1/4" 1 5/8"
2" 1"
1 3/8"
SYM.
ELEVATOR CONTRACTOR:
GENERAL CONTRACTOR:
DWN DATE
ARCHITECT:
ADDRESS:
CITY:
DATE
FOR:
DRAWING NO.JOB NUMBERBRANCH SHEET NO.REV.
OF
DO NOT SCALE THIS DRAWING
REVISION
ELEV #
BY
CAR SIGNAL
This drawing and all information thereon is the proprietary property of TK Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and is not to be used directly or indirectly in any manner detrimental to the interest of TK Elevator.
LA
TC
H A
C C
ES
S
.5
.0
[8
.0 0m m
.0
LEFT HAND PANEL
M
M
FIREFIGHTERS'
PUSH
STOP
RUN
PULLCANCEL
CALL
SMOKING
FIRE SERVICE-ANSI2016 WITH TWO WAY COMM
AN 8" X 8" DOOR TO MATCH CAR STATION FINISH. PANEL CONSIST OF FIRE
SERVICE DEVICES WITH FIRE INSTRUCTIONS INSIDE OF DOOR. "FIREFIGHTERS'
OPERATION" ON DOOR IS .438 HIGH RED LETTERS.
OPEN
NOF
OF
LOH D
F IR E OPE R.
CLOSE
FIREFIGHTERS'
OPERATION
NO
SMOKING
TEST
RESET
FO F
NO
DCAR
RER AE D
E
ND
S
I
ECRE IV
T
EN
ON
DPEN
SSACCE
LE
E
AB
N
OFF UR N
OTP
S
5.
1" [1
.5
0m m
CAR OPERATING STATION
KEY SWITCHES
THE KEY SWITCH CONSISTS OF A CHROME KEY CYLINDER MOUNTED IN
A 1 3/8"Ø BEZEL. THE GRAPHICS FOR THE KEY POSITIONS ARE PAD
PRINTED ON THE SURFACE OF THE BEZEL AND ARE COLORED WHITE.
ALARM AND FLOOR BUTTONS - V7 / V8 (WHITE)
THE PUSH-BUTTON CONSIST OF A 1 1/4"Ø HALO AROUND AN
ILLUMINATING 1 1/16"Ø CLEAR RING AND A 1"Ø BUTTON.
DOOR OPEN AND DOOR CLOSE BUTTONS - V7 / V8
THE PUSH-BUTTON CONSIST OF A 1 1/4"Ø HALO AROUND A
NON-ILLUMINATING 1 1/16"Ø CLEAR RING AND A 1"Ø BUTTON.
BRAILLE PLATES
1 1/2" DIAMETER CAST PLATES WITH WHITE CHARACTERS ON BLACK
BACKGROUND. MEETS ANSI A117.1 70% CONTRAST REQUIREMENTS.
MECHANICALLY FASTENED FROM BACK SIDE. INCLUDES ARABIC OR
N.E.I.I. DESIGNATIONS AND BRAILLE.
BRAILLE PLATE MOUNTING
MECHANICAL FASTENER
WHITE CHARACTER,
BLACK BACKGROUND
AND BRAILLE
SWING PANEL
EMERGENCY LIGHT
4 7/8" X 1 3/8" WINDOW MADE OF P-4 PLEXIGLAS.
EMERGENCY LIGHT WILL LIGHT CLEAR.
CARD READER PROVISIONS
4" x 4" AREA FOR CARD READER IS INCLUDED.
UNIT AND MOUNTING IS BY OTHERS.
ELEVATOR
CAPACITY 3500 LBS.
ELEVATOR
CAPACITY 3500 LBS.
CAPACITY PLATE
4 3/4" X 1 1/4" PLATE TO MATCH FACEPLATE
WITH BLACK TEXT. MECHANICALLY FASTENED
FROM BACK SIDE.
EMERGENCY
POWER
SILLAC DERE
AN S W
SETAIC
IN
D
IKIL N
B
NG
SILLAC DERE
ANS W
SETAIC
IN
D
IKIL N
B
NG
SPEAKER PHONE
CALL BUTTON MOUNTED IN A POLYCARBONATE PLAQUE WITH BRAILLE
AND WHITE RAISED SYMBOL AND CHARACTERS. MANDATED BUTTON
IDENTIFICATION TO MEET A17.1 CODE. COMPLETE PHONE WITH
SPEAKER INSTALLED BY TK ELEVATOR, MIDDLETON.
RETURN PANEL SKIN: STAINLESS STEEL W/ #4 BRUSH FINISH
CONTROLLER: TAC32
STATION: MAIN
TOTAL REQUIRED: 1
.0
EGK997
AIR FORCE CYBERWORX
USAF ACADEMY
COLORADO SPRINGS, CO 80840-
TKE DENVER
DENVER, CO
JM 10/06/22
EGK997Field
JM1 1 1CMK997
DESIGNED PER ASME A17.1
STAINLESS STEEL
TO BE 316 SERIES
15.250"
POSITION INDICATOR
MATISSE 10" [8.764" X 4.925" CUTOUT] FOR TWO
WAY COMMUNICATION. BLUE BACKGROUND WITH
3" WHITE TEXT.
7.
0"
5.
6"
GRAPHICS
"NO SMOKING" TO BE .625 HIGH
BLACK LETTERS.
FLUSH LOCKED COMPARTMENT
7" X 11" DOOR THAT MATCHES THE CAR STATION
FINISH. THE DOOR IS LOCKED WITH A 7 PIN ACE LOCK.
DEVICES ARE MOUNTED BEHIND ON A SUBPLATE.
GRAPHICS
ELEV.# TO BE .500" HIGH BLACK LETTERS.
CAPACITY TO BE .250" HIGH BLACK LETTERS.
CAPACITY 3500 LBS.
ELEVATOR 1
CERTIFICATE WINDOW
4" X 8" FLUSH MOUNTED PLEXIGLAS.
CARD READER PROVISIONS
A 4" X 4" PLEXIGLASS WINDOW WILL BE SUPPLIED. UNIT AND ALL
MOUNTING PROVISIONS WILL BE BY OTHERS.
EMERGENCY
POWER
TEST
RESET
FO F
NO
DCAR
RER AE D
E
ND
S
I
ECRE IV
T
EN
ON
DPEN
SSACCE
LE
E
AB
N
OFF UR N
OTP
S
C
FINAL
GRAIN TO RUN THE LENGTH
OF THE PART UNLESS OTHERWISE NOTED
SMART RESCUE PHONE
SMART RESCUE PHONE FOR 1-5 CARS TO BE PROVIDED MALE VOICE
2) LANDING ANNUNCIATION VERBIAGE (PLEASE PRINT)
* PLEASE SPECIFY BELOW FOR VOICE ANNUNCIATOR
1) PLEASE SELECT
FEMALE VOICE
FLOOR 1 FLOOR 1
FLOOR P FLOOR P
FLOOR 2 - 4 FLOOR 2, FLOOR 3, ETC.
VOICE ANNUNCIATOR
VOICE ANNUNCIATOR WILL BE MOUNTED BEHIND
3.5" [89] SPEAKER PATTERN.
ELEVATOR CONTRACTOR:
ARCHITECT:
BYREVISIONSYM.DATE
DO NOT SCALE THIS DRAWING
This drawing and all information thereon is the proprietary property of TK Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and is not to be used directly or indirectly in any manner detrimental to the interest of TK Elevator.
REV.JOB NUMBERDWN DATE BRANCH DRAWING NO.
GENERAL CONTRACTOR:
CITY:
ADDRESS:
FOR: ELEV #
OF
SHEET NO.
HALL SIGNAL
HALL STATIONS
FACEPLATE
TYPE:
FINISH:
MTG. HARDWARE:
B REZU Z
ES
RE
T
NOPH E
ELEVATOR
COMMUNICATIONS
FAILURE
COMMUNICATION
FAILURE
E NO
S
RE
T
FOF
FIRE RECALL
FIRE KEY AND TURN TO "ON"
TO RECALL ELEVATORS INSERT
FIREFIGHTERS' OPERATION
1/
4" [5
7.
m m
3/ 4"
[4 4.
m m
5/
8" [6
6.
m m
3/ 4"
[4 4.
m m
3/
4" [4
4.
m m
[6
.6 0m m
7" [177.80mm]
AT FLOOR:
ELEVATOR NO.:
TOTAL REQUIRED:
1/
4" [5
7.
m m
3/ 4"
[4 4.
m m
[3
.6 0m m
7" [177.80mm]
AT FLOOR:
ELEVATOR NO.:
TOTAL REQUIRED:
1/
8" [7
9.
m m
[3
.6 0m m
7" [177.80mm]
AT FLOOR:
ELEVATOR NO.:
TOTAL REQUIRED:
USE ONLY
EMERGENCY
FIRE DEPT.
AND
KEY
ELEVATOR
FOR
3 1/2" [88.90mm]
[2
.0 0m m
AT FLOOR:
ELEVATOR NO.:
TOTAL REQUIRED:
USE ONLY
FIRE DEPARTMENT
7" [1
.8
0m m
[2
.4
0m m
2"
2"
6" [152.40mm]
2"
10" [254.00mm]
2"
AT FLOOR:
ELEVATOR NO.:
TOTAL REQUIRED:
CUTOUT MOUNTING DATA - HALL STATIONS
FACEPLATE: 7"(177.80mm)W x 14"(355.60mm)H WITH MTG. HARDWARE: 5"(127.00mm)W x 12 1/8"(307.98mm)H O.C.
BOX: 6 1/16"(153.99mm)W x 13"(330.20mm)H X 2 1/2"(63.50mm)D CUTOUT: 6 3/16"(157.16mm)W x 13 1/8"(333.38mm)H
CUTOUT MOUNTING DATA - HALL STATIONS
FACEPLATE: 7"(177.80mm)W x 24"(609.60mm)H WITH MTG. HARDWARE: 5"(127.00mm)W x 22 1/8"(561.98mm)H O.C.
BOX: 6 1/16"(153.99mm)W x 23"(584.20mm)H X 2 1/2"(63.50mm)D CUTOUT: 6 3/16"(157.16mm)W x 23 1/8"(587.38mm)H
CUTOUT MOUNTING DATA - EMERG. KEY BOX
FACEPLATE: 3 1/2"(88.90mm)W x 10"(254.00mm)H WITH MTG. HARDWARE AT 8 5/16"(211.15mm) O.C.
BOX: 2 3/4"(69.85mm)W x 9"(228.60mm)H X 1 7/8"(47.63mm)D CUTOUT: 2 7/8"(73.03mm)W x 9 1/8"(231.78mm)H
WINDOW
2 1/4" X 2 1/4" GLASS WINDOW WITH BLACK
LETTERING.
CUTOUT MOUNTING DATA - FIRE KEY BOX
FACEPLATE: 10"(254.00mm)W x 11"(279.40mm)H WITH MTG. HARDWARE: 8 1/16"(204.80mm)W x 9 1/16"(230.20mm)H O.C.
BOX: 9 1/8"(231.78mm)W x 9 3/4"(247.65mm)H X 4"(101.60mm)D CUTOUT: 9 1/4"(234.95mm)W x 9 7/8"(250.83mm)H
GRAPHICS
1/4" HIGH, COLORED RED.
FIRE SERVICE - ANSI2016
1 3/8" DIA. RED BEZEL WITH WHITE LETTERING.
KEY IS REMOVABLE IN "OFF" & "ON" POSITIONS.
KEY IS NOT REMOVABLE IN "RESET" POSITION.
1 3/8" DIA. BEZEL, 1" DIA. BLACK JEWEL, AND
1 1/4" DIA. HALO. HALO AND FIRE HAT
ILLUMINATE RED.
METAL BUTTONS - V7 / V8 (WHITE)
1 1/4" DIA. HALO AROUND AN ILLUMINATING
1 1/16" DIA. CLEAR RING AND A
1" DIA. BUTTON
PICTOGRAPH ENGRAVED
FIRE FLAME IS COLORED SOLID RED. CIRCLES, SLASHES,
AND SYMBOLS TO BE BLACK ON WHITE BACKGROUND.
ALL LETTERING TO BE BLACK.
ENGRAVING
TITLES ARE 1/4"H, 3/16"H INSTRUCTIONS. ALL
COLORED RED. HELVETICA MEDIUM LETTERING.
COMBINATION P.I./HALL LANTERNS
FACEPLATE
TYPE:
FINISH:
MTG. HARDWARE:
AT FLOOR:
ELEVATOR NO.:
TOTAL REQUIRED:
19 3/8" [492.13mm]
1/
2" [1
.3
0m m
CUTOUT MOUNTING DATA
FACEPLATE: 19 3/8"(492.13mm)W x 4 1/2"(114.30mm)H WITH MTG. HARDWARE AT 17 7/16"(442.91mm) O.C.
BOX: 18 1/8"(460.38mm)W x 3 3/4"(95.25mm)H x 2 1/2"(63.50mm)D CUTOUT: 18 1/4"(463.55mm)W x 3 7/8"(98.43mm)H
CHIME
AN INTERNALLY MOUNTED ADJUSTABLE CHIME SOUNDS
SIMULTANEOUSLY WITH ILLUMINATION OF A LANTERN.
CHIME SOUNDS ONCE FOR UP, TWICE FOR DOWN.
LANTERNS
2 1/2" x 2 1/2" WHITE LEXAN PLASTIC LENSES
WHICH ILLUMINATE UPON CAR ARRIVAL TO
INDICATE DIRECTION OF TRAVEL.
ILLUMINATION:
POSITION INDICATOR (BLUE)
THE POSITION INDICATOR CONTAINS
5x7 DOT MATRIX DISPLAYS.
DISPLAY TO READ:
EGK997
AIR FORCE CYBERWORX
USAF ACADEMY
COLORADO SPRINGS, CO 80840-
TKE DENVER
DENVER, CO
JM 10/06/22
EGK997Field
JM1 HFK997 1 1
DESIGNED PER ASME A17.1
STAINLESS STEEL
TO BE 316 SERIES
VERTICAL
11 GAUGE STAINLESS STEEL W/ #4 BRUSH FINISH
SPANNER HEAD SCREWS
KEYSWITCH FINISH: CHROME
2,3
M
HORIZONTAL
11 GAUGE STAINLESS STEEL W/ #4 BRUSH FINISH
SPANNER HEAD SCREWS
GREEN FOR UP, RED FOR DOWN
1-3,M
OD
UP
FO F
SSACCE
NW
1/
2" [1
.3
0m m
9" [2
.6
0m m
3 1/2" [88.90mm]
AT FLOOR:
ELEVATOR NO.:
TOTAL REQUIRED: 2
1,M
CUTOUT MOUNTING DATA - HALL STATIONS
FACEPLATE: 3 1/2"(88.90mm)W x 9"(228.60mm)H WITH MTG. HARDWARE AT 7 3/16"(182.56mm) O.C.
BOX: 2 3/4"(69.85mm)W x 8"(203.20mm)H x 2 1/2"(63.50mm)D CUTOUT: 2 7/8"(73.03mm)W x 8 1/8"(206.38mm)H
C
AT FLOOR:
ELEVATOR NO.:
TOTAL REQUIRED:
19 3/8" [492.13mm]
1/
2" [1
.3
0m m
AT FLOOR:
ELEVATOR NO.:
TOTAL REQUIRED:
19 3/8" [492.13mm]
1/
2" [1
.3
0m m
2,3
M
FINAL
GRAIN TO RUN THE LENGTH
OF THE PART UNLESS OTHERWISE NOTED
Elevators Are Out Of Service
Use Exit
In Case Of Fire Elevators Are Out Of Service
Use Exit
In Case Of Fire
Elevators Are Out Of Service
Use Exit
In Case Of Fire
| Appendix 5 Elevator Dimensions |
| 14 24 23-1.4 Elevator Layout Drawings AIR FORCE CYBERWORX - Rev2 |
| BCI Submittal Cover Page |
| Text1#1: Hydraulic Passenger Elevator |
| Text2#1: 14 24 23 |
| Text3: 14 24 23-1.4 |
| Text4: 14 24 23 |
| Text7: Terri Napier |
| Text6: 5/5/2023 |
| Check Box1: Yes |
| Check Box2: Off |
| Check Box3: Off |
| Check Box4: Off |
| Text5: W9128F22C0025 |
| <<CabColorInfo2>>: CAB FLOORING THICKNESS: |
| <<CabType1>>: CAB TYPE: |
| <<CabType2>>: CAB PANEL: |
| <<CabType3>>: REVEALS: |
| <<CabType4>>: BASE: |
| <<CabType5>>: CAB CEILING: |
| <<CabType6>>: CAB CEILING FINISH: |
| <<CabType7>>: CAB DOOR: |
| <<CabType8>>: CAB SILLS: |
| <<CabType9>>: CAB HANDRAIL(S): |
| <<CabType10>>: HANDRAIL(S) FINISH: |
| <<CabType11>>: CAB PROTECTION: |
| CabTypeFeature1-: APPLIED PANEL |
| CabTypeFeature2-: #4 316 STAINLESS |
| CabTypeFeature3-: #4 316 STAINLESS |
| CabTypeFeature4-: #4 316 STAINLESS |
| CabTypeFeature5-: DOWN LIGHT - METAL PAN CEILING |
| CabTypeFeature6-: #4 316 STAINLESS |
| CabTypeFeature7-: #4 316 STAINLESS |
| CabTypeFeature8-: NICKEL SILVER |
| CabTypeFeature9-: (3) 1/4" x 2" CONTINUOUS FLAT BAR |
| CabTypeFeature10-: #4 316 STAINLESS |
| CabTypeFeature11-: PAD BUTTONS PROVIDED (1) PADS |
| PrimaryFireServiceFloor2-: 1 |
| FloorMarkings1-: M |
| FloorMarkings2-: 3 |
| FloorMarkings3-: 2 |
| FloorMarkings4-: 1 |
| Wall Thickness1-: 4 1/8" |
| Wall Thickness2-: 4 1/8" |
| Wall Thickness3-: 4 1/8" |
| Wall Thickness4-: 4 1/8" |
| Entrance Door Finish1-: #4 Stainless |
| Entrance Door Finish2-: #4 Stainless |
| Entrance Door Finish3-: #4 Stainless |
| Entrance Door Finish4-: #4 Stainless |
| Entrance Frame Finish1-: #4 Stainless |
| Entrance Frame Finish2-: #4 Stainless |
| Entrance Frame Finish3-: #4 Stainless |
| Entrance Frame Finish4-: #4 Stainless |
| AlternateFireServiceFloor-: 2 |
| PushButtonIllumination1-: VANDAL RESISTANT LED COLOR: |
| PositionIndicatorIllumination1-: POSITION INDICATOR ILLUM: |
| <<CabColorInfo1>>: CAB FLOORING WEIGHT LBS: |
| field_1: 150 lbs |
| field_2: 3/8" |
| field_3: WHITE LED |
| Wall Type1-: Drywall |
| Wall Type2-: Drywall |
| Wall Type3-: Drywall |
| Wall Type4-: Drywall |
| field_4: Blue |
File details come from the government source that posted it. Updated .