Appendix 5 Elevator Dimensions.pdf

PDF 3 MB Posted

Attached to
Furniture, Delivery and Installation at USAFA Madera Cyber Innovation Center
Solicitation number
FA700024Q0030
Issued by

About this file

This document is an appendix that provides the elevator dimensions for a federal contract opportunity. The appendix specifies the capacity, height, width, depth, and entry door dimensions for the elevator system. It includes details on the transmittal form for submitting shop drawings, equipment data, material samples, or manufacturer's certificates of compliance. The elevator system must meet the requirements outlined in the contract documents.

The related federal contract opportunity is for the purchase, delivery, and installation of furniture for the Madera Cyber Innovation Center at the USAF Academy in Colorado. The solicitation is an open competition for responsible sources to submit quotes. The Department of the Air Force Headquarters Air Force Academy is the procuring agency, and a purchase order will be established with one quoter.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Appendix 5: Elevator specifica ons

Elevator Dimensions Summary

Capacity: 3500 LB

Height: 8’3”

Width: 6’8”

Depth: 5’5”

Entry Door: 8’ height by 3’6” wide (~8’7” diagonal)

For use of this form, see ER 415-1-0; the proponent agency is CECW-CE

TRANSMITTAL OF SHOP DRAWINGS, EQUIPMENT DATA, MATERIAL SAMPLES, OR

MANUFACTURER'S CERTIFICATES OF COMPLIANCE

U.S. Army Corps of Engineers (USACE) DATE

5/5/2023 14 24 23-1.4

TRANSMITTAL NO.

SECTION I - REQUEST FOR APPROVAL OF THE FOLLOWING ITEMS (This section will be initiated by the contractor)

CONTRACT NO.

W9128F20C0038

CHECK ONE:

THIS IS A NEW TRANSMITTAL

THIS IS A RESUBMITTAL OF

TRANSMITTAL 14 24 23-1.3

SPECIFICATION SEC. NO. (Covers only one section with each transmittal)

14 24 23-HYDRAULIC PASSENGER ELEVATOR

PROJECT TITLE AND LOCATION

FY18 DB CyberWorx,USAF Academy, CO

THIS TRANSMITTAL IS FOR: (Check one)

FIO GA X DA CR DA/CR DA/GA

TO:

Air Force Academy Resident Office 8110 Security Drive, Suite 7 U.S. Air Force Academy, CO 80840

FROM: Federal/Bryan 5475 Tech Center Drive, Suite 300 Colorado Springs CO 80919

USA

ITEM

NO. DESCRIPTION OF SUBMITTAL ITEM

SUBMITTAL

TYPE CODE

NO.

OF

COPIES

CONTRACT DOCUMENT

REFERENCE CONTRACTOR

REVIEW

CODE

VARIATION

USACE

ACTION

CODE

(See Note 3)

(Type size, model number/etc) (See Note 8)

SPEC.

PARA. NO.

DRAWING

SHEET NO.

Enter "Y" if requesting a variation

(See Note 6)

(Note 9)

a. b. c. d. e. f. g. h. i.

1 Elevator System 02 - SHOP 0 2.1 A No

The shop drawings have been corrected to match the contract documents.

REMARKS

NAME OF CONTRACTOR SIGNATURE OF CONTRACTOR

I certify that the above submitted items had been reviewed in detail and are correct and in strict conformance with the contract drawings and specifications except as otherwise stated.

ENCLOSURES RETURNED (List by Item No.) DATE

SECTION II - APPROVAL ACTION

NAME AND TITLE OF APPROVING AUTHORITY SIGNATURE OF APPROVING AUTHORITY

ENG FORM 4025, MAY 2017 Page 1 of 1PREVIOUS EDITIONS ARE OBSOLETE.

F

Digitally signed by tnapier@bryanconstruction.com Date: 2023.05.05 11:39:48 -06:00

Benjamin Alter, Contracting Officer's Representative Digitally signed by ALTER.BENJAMIN.DAVID.1154216010 Date: 2023.05.24 10:23:14 -06:00 Contracting Officer's Representative

PROJECT TITLE FY18 DB CyberWorx

LOCATION USAF Academy, CO

DATE

05/24/2023

TRANSMITTAL NO.

14 24 23-1.4

Item Description Variation QA Code

1 Elevator System No F

SECTION III - GOVERNMENT REVIEW REMARKS

No remarks

CONTRACT NO.

W9128F20C0038

PAGE

TRANSMITTAL OF SHOP DRAWINGS, EQUIPMENT DATA

MATERIAL SAMPLES, OR MANUFACTURER'S

CERTIFICATES OF COMPLIANCE

Attachment to ENG FORM 4025-R

***PLEASE USE THE SPACES BELOW FOR COMMENTS AND STAMPS***

Submittal Approval Sheet

BRYAN CONSTRUCTION INC.

Reviewed for general conformance with the contract documents.

Review of this submittal does not relieve the subcontractor/supplier of responsibility for full compliance with the plans, specifications and conditions of the contract documents. Dimensions, quantities, errors, omissions and the furnishing of all items required, whether shown in the submittal or not, shall remain the responsibility of the subcontractor/supplier.

Submittal No. Specification Number

Project No. Date:Reviewed By:

0001 26 05 33

11033 John Snyder 7/12/12

BRYAN CONSTRUCTION INC.

Reviewed for general conformance with the contract documents.

Review of this submittal does not relieve the subcontractor/supplier of responsibility for full compliance with the plans, specifications and conditions of the contract documents. Dimensions, quantities, errors, omissions and the furnishing of all items required, whether shown in the submittal or not, shall remain the responsibility of the subcontractor/supplier.

Submittal No. Specification Number

Project No. Date:Reviewed By:

BCI REVIEWER NOTES:

-Note all markings in GREEN on the submittals below.

-Unless noted otherwise, the comments by BCI are to be considered as "Make Corrections Noted" and the responsibility will belong to the subcontractor in making the correction or verification noted.

o NO EXCEPTIONS TAKEN o REVISE AND RESUBMIT o MAKE CORRECTIONS NOTED o SUBMIT SPECIFIED ITEM

Specification Section:

Item / Description jpatton Text Box The shop drawings have been corrected to match the contract documents.

mcollins Typewritten Text

For Project

AIR FORCE CYBERWORX

TKE Job Number: EGK997

Elevator: 1

Located at

USAF ACADEMY

COLORADO SPRINGS,CO 80840

Company (Mail To)

Bryan Construction 5475 Tech Center Drive, Ste 300

Colorado Springs, CO 80919

Phone:

Attention:

Brett Kmetz

Final Drawing

Approved

May 3, 2023

460 Volts A.C. 3 Phase 60 Cycles

THE FOLLOWING POWER INFORMATION HAS BEEN CONFIMED:

BUILDING POWER:

SUMMARY OF FINAL APPROVAL SECTIONS

ELEVATOR DESIGNATION:

FACTORY JOB NUMBER: EGK997

APPROVED CAB AND FIXTURE SELECTIONS

APPROVED ENTRANCE INFORMATION APPROVED POWER CONFIRMATION

MAIN EGRESS FLOOR (Fire Service):

FLOOR

MARKINGS WALL TYPE

WALL

THICKNESS (X)

ENTRANCE

DOOR FINISH

ENTRANCE

FRAME FINISH

ALTERNATE FLOOR (Fire Service):

FINAL DRAWINGS APPROVED

FEATURES FOR YOUR FIXTURES

SUBMITTAL MARKUP INSTRUCTION

REVISION HISTORY (CSC USE ONLY)

VOIDED/REFUSED MARKUP REQUESTS (CSC USE ONLY)

1. ALL MARKUPS SHOULD BE CLEAR, LEGIBLE, AND CONCISE.

2. ALL MARKUPS SHOULD CORRESPOND WITH MOST RECENT REVISION.

3. NOTE: ADDITIONAL MARKUPS SENT TO COORDINATOR DURING A REVISION CYCLE WILL NOT BE CONSIDERED. FIELD MUST WAIT UNTIL THE

REVISION IS COMPLETE AND PROVIDE MARKUPS ON THE MOST RECENT REVISION.

4. ALL MARKUPS SHOULD BE CIRCLED AND NUMBERED TO IDENTIFY THE CHANGE REQUEST.

5. ITEMS CIRCLED, HIGHLIGHTED, OR CROSSED THROUGH WITHOUT COMMENTS WILL NOT BE ADDRESSED.

6. REVISIONS TO THE SUBMITTALS WILL NOT PROCEED IF THE MARKUP STANDARD IS NOT FOLLOWED.

7. IF DOCUMENTS ARE REFERENCED ON THE MARKUPS, THE REFERENCED DOCS MUST BE INCLUDED IN THE RETURNED SUBMITTAL PACKAGE.

REVISION HISTORY CONT'D (CSC USE ONLY)

DRAWN DATE JOB NUMBER REV. SHEET NO.CHKD.

AIR FORCE CYBERWORX HMD 10/5/22 X EGK997 1 OF 1C

LAYOUT SUBMITTAL REVISION COVER SHEET

JOB NAME

ADDENDUM - CLARIFICATIONS NEEDED

1' -6

3" O

IL

IN

LE

T

1' -4

/2

AB

O

VE

P

IT

F

LO

O R

3' -6

7' -3

/2

" B

ET

W

EE

N R

AI

LS

6' -8

" C

LE

AR

IN

SI

D

E

1' -1

4' -9

" R O

U G

H O

PE

N

IN

G

8' -8

" C

LE

AR

H

O

IS

TW

AY

3' -6

S

1' -6

3' -6

" C

LE

AR

O

PN

G

3' -6

" C

LE

AR

O

PN

G

H

AL

L

ST

AT

IO

N W

FI

R E

SV

C

. S W

LC

BU

FF

ER

1/

2"

3/

4"

BU

FF

ER

LC

SWS.

C .S

= RAIL BRACKET MOUNTING SURFACE

7' -0

" P

LA

TF

O

R M

3'-7 3/4"

3'-1 1/2"

6'-3" PLATFORM

8'-0 1/2" TUBE STEEL TO TUBE STEEL

6 1/4"

5'-5" CLEAR INSIDE

1'-9 1/4"

PLATFORM

TO WALL

8" DEEP TUBE STEEL

BY OTHERS (TYP)

3' -3

" 4' -1

A

3' -5

/2

A

R =1

2, 3/

4" F

AC

E

O F

R

AI

L

3/

4"

5"

R

AI

L

LI

N E

A

R =1

2, R

AI

L

LI

N E

B

3"

AC

C

ES

S

SW

EACH OTHER ) CLEAR REQ'D. IN FRONT OF

ALL ELECTRICAL PANELS

NOTE: MIN. OF 3'-6" ( 4'-0" WHEN FACING

9' -1

20,132 BTU/HR

HEAT LOAD =

10'-9 1/2"

4'-0" X 8'-0"

DISC. SW. ABOVE CAR LIGHT, ALARM

CIRCUIT AND JCT. BOX

CIRCUIT W/DISC. SW. AND/OR PHONE

3' -6

" M

IN

ELEVATOR

NUMBER

MOTOR

HP.

RATED

AMPS

STARTING

AMPS

MAX. UP ACC.

AMPS (FULL

LOAD)

60 76.0 228 108

H L

,3 ,M

H L/

PI

MACHINE ROOM LOCATED ADJACENT TO HOISTWAY @ 1ST. FLOOR.

PLAN OF HOISTWAY & MACHINE ROOM

6'-2"

3' -3

/8

"9 1/2" AB. FLOOR

3" OIL LINE

SHEAVE SIDE

TANK HT. = 7'-3 1/2"C

O

N

TR

O

LL

ER

4'

-9

/4 " H

IG

H

3'-6" MIN.

2' -0

" M

IN

NOTE:

OIL COOLER REQUIRES A SEPARATE

120V, 1PH, 60 CYCLE, 20A CIRCUIT.

SU

M

P

PI

T

C O

VE

R

BY

O

TH

ER

S.

SCCR*

AMPS

10,000

*45 kA AND 600V OR LESS IF PROTECTED BY CLASS J FUSES SIZED

FOR THE APPLICATION ( CLASS J FUSE IS PROVIDED BY OTHERS.)

PIPE. ASTM A-53; TYPE E OR S

3" OIL LINE FROM TANK TO 3"

SHUTOFF VALVE. 3" SCH 40 BLK

GRADE B OR EQUIVALENT TO JACK.

C

3' -6

" M

IN

PR

IM

AR

Y

EQ

U

IP

. B

O X

NOTE:

PRIMARY EQUIP. BOX REQUIRES A SEPARATE

120V, 1PH, 60 CYCLE, 20A CIRCUIT.

9' -1

" W

AL

L

TO

W

AL

L

1/

2"

1/ 2"

DRY POWER UNIT

NOTE:

VERIFY OIL COOLER LOCATION.

9'-3 1/2" 1'-0" 6"

NOTE A: OIL PIPE LINES AND FITTINGS SHALL BE PROPERLY SUPPORTED TO RELIEVE STRAIN.

NOTE C: TK ELEVATOR TO BE NOTIFIED OF ANY CHANGE TO ELEVATOR

NOTE D: ELEVATOR DESIGN AND FABRICATION BASED ON ESTIMATED CAB WEIGHT SHOWN.

LAYOUT APPROVAL WILL BE CONSTRUED AS FINAL CAB WEIGHT, UNLESS

HOISTWAY OR MACHINE ROOM DESIGN.

OTHERWISE NOTIFIED.

NOTE B: ALL REACTIONS INCLUDE ALLOWANCE FOR IMPACT.

DATE SYM REVISION BY

REV

C

F2

IS PROVIDED, AN AUXILIARY CONTACT SHALL ALSO BE INSTALLED ON THE CIRCUIT BREAKER."

F2

RAIL FORCES F1F1

LBS.

1F 2F

LBS.

NOTE: MUST BE LOCATED AS DIRECTED BY ELEVATOR CONTRACTOR.

"IF STANDBY POWER TYPE 10D-0C IS PROVIDED, AN AUXILIARY CONTACT SHALL BE INSTALLED ON THE DISCONNECT SWITCH FOR EACH CAR. THE AUXILIARY CONTACT SHALL BE CONFIGURED AS SPST

PIPE SLEEVES, TRENCHING, AND BACK FILLING FOR OIL AND/OR CONDUIT LINES AS SHOWN

OR LOCATED BY ELEVATOR CONTRACTOR.

A SQUARE HOLE IN PIT FLOOR FOR SETTING OF JACK AND FILL WITH CONCRETE

CONDUIT AND WIRING FROM HOISTWAY TO ELEVATOR MONITORING PANELS (FOR SECURITY,

LIFE, SAFETY, OR FIRE REQUIREMENTS).

SMOKE SENSORS (AS REQUIRED).

WHEN THE DISCONNECT SWITCH IS IN THE OPEN POSITION. IF A SHUNT TRIP CIRCUIT BREAKER

AND BE RATED AT NO LESS THAN 1A AT 110 VAC. THE AUXILLARY CONTACT SHOULD BE OPEN

POCKETS IN CORRIDOR WALL (PER FIXTURE DRAWINGS) FOR HALL FIXTURES.

AFTER JACK IS SET.

14.

13.

10.

12.

11.

9.

INSTALLATION PROCEDURES FOR FRAME-TO-WALL INTERFACE DETAILS TO ENSURE CONFORMANCE

THE FOLLOWING CONDITIONS MUST BE MET BEFORE INSTALLATION

IS COMPLETED, AND ARE NOT INCLUDED IN THE ELEVATOR CONTRACT:

A PLUMB, PROPERLY-VENTILATED HOISTWAY (ACCORDING TO CODE AND SIZES SHOWN).

ENTRANCE WALL WITH LINTELS. NOTE: MUST BE PROVIDED AFTER ENTRANCE FRAMES ARE SET

- OR LEAVE A ROUGH OPENING 1'-3" WIDER AND 1'-3" HIGHER THAN THE FRAME OPENING. SEE

SEPERATE 120 VOLT, 15 AMP BRANCH CIRCUITS, ALONG W/ TELEPHONE CIRCUIT TO TERMINALS OF EACH REQ'D CONTROLLER FOR EACH OF THE FOLLOWING: 1) CAR LIGHT AND ALARM CIRCUIT

CAR (ACCORDING TO CODE). NOTE: MUST BE CLEAR OF ALL ELEVATOR EQUIPMENT.

PIT LIGHTS AND SWITCH, CONVENIENCE OUTLETS (GFCI TYPR PER NEC), 1 PIT LADDER PER

HOISTWAY BARRICADES (ALL CUTTING AND PATCHING TO INSTALL HOISTWAY ENTRANCES, SILLS, ADEQUATE SUPPORT FOR JACK, GUIDE RAIL BRACKETS, AND BUFFERS (FOR REACTIONS SHOWN).

AND HALL FIXTURES).

BRANCH-CIRCUIT CONDUCTOR SIZING, MATERIALS, AND INSULATION (INCLUDING BRANCH-CIRCUIT

W/ GFCI TYPE RECEPTACLES PER NEC. 2) GROUP CONTROL AS REQ'D. NOTE: IF STANDBY POWER

OVERCURRENT PROTECTIVE DEVICE) TO COMPLY WITH ALL LOCAL ELECTRICAL CODES (SEE

IS SUPPLIED, GROUP CONTROL CIRCUIT MUST BE STANDBY POWER BACKED.

"ELECTRICAL POWER REQUIREMENTS").

LEAVE WALL OUT UNTIL EQUIPMENT IS IN PLACE.

AN ENCLOSED MACHINE AREA (ACCORDING TO CODE), WITH ADEQUATE LIGHT, HEAT, AND

NOTE: MUST PROVIDE ADEQUATE DOOR SIZE TO ALLOW INSTALLATION OF EQUIPMENT - OR

VENTILATION (MIN. 50°F., MAX. 90°F. WITH NON-CONDENSING HUMIDITY OF 10-90%), AND

NOTE: IF STANDBY POWER IS REQUIRED, SEE "ELEVATOR STANDBY POWER OPERATION".

8.

7.

6.

5.

4.

3.

2.

1.

HYDRAULIC ELEVATOR CONTRACT DATA

CLEARANCE BET. PIT FL. AND CAR BOLSTER ON COMP'D BUFFERS

BUFFER TYPE SPRING BUFFER STROKE

MAX. LTH. OF ANY ONE PC. SECTION OF JACK PLGR. OR CYLINDER NOT TO EXCEED

IN.

PLUNGER O.D.

EST. WORKING PRESSURE

CYLINDER WALL THICKNESS

PLUNGER NET AREA

PLUNGER WALL TH'K'S.

CYLINDER O.D.

CYLINDER CPLG.

ELEVATOR NUMBER

SPEED DOWN FULL LOAD

POWER UNIT

JACK MODEL

MOTOR

STOPS

SPEED UP

MAX. AXLE LOAD

MAX. SUSTAINING LOAD

MAX. UNIT LOAD

OPERATION

CAPACITY

TYPE

BOTTOM RUNBYIN. IN.

TOTAL CAR WT. WITH

EST. CAB WT. W/O DOOR OPERATOR

LBS.

POWER UNIT WT. ( INCL. OIL WT.)

PIT CHANNELS

PLUNGER WT.

P.S.I.

REQ'D.

IN.

SQ. IN.

IN.

IN.

O.D.

LBS.

IN.

LBS.

LBS.

LG.

POWER SUPPLY V. 3 PH. CY.

CAR GUIDE RAILS

TOP OVERTRAVEL

BOTTOM OVERTRAVEL

HOISTWAY ENTRANCES

CAR DOOR

BALANCE WT. FILLERS

PLATFORM FL. TH'K'S.

BOLSTER

CROSSHEAD

GUIDE TYPE

CAR ENCLOSURE

-S

HP

F.P.M.

F.P.M.

LBS.

LBS.

LBS.

LBS.

STILE

IN.

IN.

LBS.

IN.

SEALED CONCRETE FLOOR SLAB SURFACE.

WITH THE LABELED ENTRANCE INTERFACE CONSTRUCTION.

NOTE: ALSO, A FOURTH WIRE TO SAME SIZE AS THREE PHASE WIRES IS REQUIRED FOR

GROUNDING PURPOSES TO MINIMIZE ELECTRICAL NOISE INTERFERENCE. THE GROUNDING WIRE

MUST BE CONNECTED TO THE BUILDINGS ELECTRICAL SYSTEM GROUND.

PASSENGER CLASS A

TAC32

AP-350

7.488 0.362 44.032 10 3/4 1/4

12 1

480 60 F6 X 6.26 F6 X 5.70 F8 X 7.68

4 1/8

APPLIED PANEL

4" ROLLER

15# TEE

SINGLE SPEED

SINGLE SPEED

C7 X 9.8 X 4'-10 1/2"

52'-8"

2 1/2 2'-3 3/8"

2'-6"

470 330

DRAWN DATE

GENERAL CONTRACTOR:

ARCHITECT:

CITY:

ADDRESS:

ELEVATOR CONTRACTOR:

FOR:

JOB NUMBERCKD

OF

SHEET NO

CONTRACT NUMBER

THIS DRAWING AND ALL INFORMATION THEREON IS THE PROPRIETARY PROPERTY OF TK ELEVATOR, AND MUST NOT BE MADE PUBLIC OR COPIED. THIS DRAWING IS LOANED SUBJECT TO RETURN ON DEMAND AND IS NOT TO BE USED, DIRECTLY OR INDIRECTLY, IN ANY MANNER DETRIMENTAL TO THE INTEREST OF TK ELEVATOR.

HMD 10/5/22 EGK997

AIR FORCE CYBERWORX

USAFA

COLORADO SPRINGS, 80804

CLARKNEXSEN

BRYAN CONSTRUCTION

TK ELEVATOR

DENVER, CO

1 2

Shaft Wall

Tube Steel

49'-7" NET TRAVEL13'-3" MIN. CLEAR OVERHEAD

9'-3" TOP OF CAB IN FULL TOP

OVERTRAVEL w/ 8'-10" O.A. CAB HT.

9'-7"

10'-0" UNDER CROSSHEAD

4'-0" MIN.

(REFUGE SPACE)

2"

M

EZ

ZA

N

IN

E

EL

. 4

9' '-7

4'-0" PIT

2'-1 1/2"

JACK SETTING

53'-9 7/16"

BOTTOM LANDING TO BOTTOM OF JACK

1'-5"

10'-7"

9'-3" ROUGH OPNG. TYP.

8'-0" CLEAR OPNG. TYP.

1S T

FL

O

O R

EL

. 0

'-0

BRACKET (TYP.)

51'-7 15/16"

CYLINDER LENGTH

PLUNGER LENGTH

= 51'-3 516"

R = 22,392 LBS.

D

ES

IG

N

L O

AD

,2

L

BS

(S

TA

TI

C , N

O T

IM

PA

C T)

D

IR

EC

TE

D B

Y

TK

E

LE

VA

TO

R F

IE

LD

O

FF

IC

E

PR

O

VI

D

ED

IN

ST

AL

LE

D B

Y O

TH

ER

S, A

S R

EM

O

VA

BL

E

SA

FE

TY

B

EA

M R

EQ

'D

. P

ER

O

SH

A

.5

3' -7

/4

SECTION A-A

MAXIMUM ALLOWABLE BRACKET SPAN = 15'-9"

9'-7"

DIA. = 14"

HDPE CASING

17'-0"

4"

2N D

F

LO

O R

EL

. 1

7' -0

9'-7"

3R D

F

LO

O R

EL

. 3

9' -0

22'-0"

16'-0" RAIL16'-0" RAIL16'-0" RAIL8'-0" RAIL10'-8" RAIL

TOTAL JACK WT.

= 3567 LBS

NOTE:

TWO SECTION JACK SHIPPED

ASSEMBLED.

4"4"

SYMDATE REVISION BY

REV.

CDO NOT SCALE THIS DRAWING

DATE CAD SHEET NO.JOB NUMBER

OF

FOR:

THIS DRAWING AND ALL INFORMATION THEREON IS THE PROPRIETARY PROPERTY OF TK ELEVATOR AND MUST NOT BE MADE PUBLIC OR COPIED. THIS DRAWING IS LOANED SUBJECT TO RETURN ON DEMAND AND IS NOT TO BE USED, DIRECTLY OR INDIRECTLY, IN ANY MANNER DETRIMENTAL TO THE

INTEREST OF TK ELEVATOR.

10/5/22 HMD EGK997

AIR FORCE CYBERWORX

2 2

SUBMITTAL MARKUP INSTRUCTION

REVISION HISTORY (CSC USE ONLY)

1. ALL MARKUPS SHOULD BE CLEAR, LEGIBLE, AND CONCISE.

2. ALL MARKUPS SHOULD CORRESPOND WITH MOST RECENT REVISION.

3. NOTE: ADDITIONAL MARKUPS SENT TO COORDINATOR DURING A REVISION CYCLE WILL NOT BE CONSIDERED. FIELD MUST WAIT UNTIL THE

REVISION IS COMPLETE AND PROVIDE MARKUPS ON THE MOST RECENT REVISION.

4. ALL MARKUPS SHOULD BE CIRCLED AND NUMBERED TO IDENTIFY THE CHANGE REQUEST.

5. ITEMS CIRCLED, HIGHLIGHTED, OR CROSSED THROUGH WITHOUT COMMENTS WILL NOT BE ADDRESSED.

6. REVISIONS TO THE SUBMITTALS WILL NOT PROCEED IF THE MARKUP STANDARD IS NOT FOLLOWED.

7. IF DOCUMENTS ARE REFERENCED ON THE MARKUPS, THE REFERENCED DOCS MUST BE INCLUDED IN THE RETURNED SUBMITTAL PACKAGE.

DRAWN DATE JOB NUMBER REV. SHEET NO.CHKD.

AIR FORCE CYBERWORX JM 10/6/22 JM EGK997 1 OF 1C

ARCHITECTURAL SUBMITTAL REVISION COVER SHEET

JOB NAME

REVISION HISTORY (CSC USE ONLY)

VOIDED/REFUSED MARKUP REQUESTS (CSC USE ONLY)

ADDENDUM - CLARIFICATIONS NEEDED

ENTRANCE

REV.JOB NUMBERBY DATE BRANCH DRAWING NO.

OF

SHEET NO.

This drawing and all information thereon is the proprietary property of TK Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and is not to be used directly or indirectly in any manner detrimental to the interest of TK Elevator.

ELEVATOR CONTRACTOR:

ARCHITECT:

GENERAL CONTRACTOR:

CITY:

ADDRESS:

FOR:

BYREVISIONREV.DATE

DO NOT SCALE THIS DRAWING

ELEV #

NOTES

RAISED DOOR

JAMB SYMBOLS

D O

O R

"B" + 3 1/2"

5"

MIN.

FINISHED

SILL LINE

WALL

LINE

3/4"

8"

POCKET

SECTION

1 7/8"

1/4" DOOR

TO FRAME

1 3/16" DOOR

2 1/16" DOOR

TO SILL

1/8"

EGK997

AIR FORCE CYBERWORX

USAF ACADEMY

COLORADO SPRINGS, CO 80840-

TKE DENVER

DENVER, CO

JM 10/06/22

JM1 1 1EGK997E1

EGK997ASAP

DESIGNED PER ASME A17.1

STAINLESS STEEL

TO BE 316 SERIES

M721 SILL SUPPORT

BY TKE

16 GA.

16 GA.

" C

/L

.1 0.

C

FR

P ar t 3

8' -0

" C

LE

AR

(F

R

AM

E) O

PE

N

IN

G

8' -2

" O

VE

R

AL

L

FR

AM

E

H

EI

G H

T 9'

-7

/4 " M

IN

IM

U M

F

LO

O R

T O

F

LO

O R

H

EI

G H

T

2"

THIS FRAME HAS A 2 HOUR WARNOCK HERSEY LABEL.

GC NOTE:

GENERAL CONTRACTOR RESPONSIBLE FOR HOISTWAY REINFORCING

AT FLOOR SLAB BEFORE INSTALLATION OF ENTRANCE FRAMES.

MINIMUM OF 4" HIGH x 8" WIDE REINFORCED CONCRETE, REINFORCED

FILLED BLOCK, WOOD OR STEEL BEAMS AT THE WALL LINE ON EACH SIDE

OF OPENING REQUIRED FOR ANCHORING SILL SUPPORT ASSEMBLY.

REINFORCING TO BE LOCATED WITH RESPECT TO REACTION POINTS.

REFERENCE INSTALLATION DRAWINGS 494JT, AND 494JV

ARE AVAILABLE UPON REQUEST.

REACTIONS (LBS.) DUE TO LOADS ON DOOR PANELS. APPROX. HORIZ.

LOADS AND LOCATIONS TO BUILDING SHOWN PER ASME A17.1, PART II.

THE SPECIFIED LOADS ARE CONSIDERED IMPACTED.

WALL TYPE FRAME FINISH DOOR FINISH

OVERALL

FRAME

"B" DIM.

FRONT REARFRONT REAR ACTUAL FRONT REAR FRONT REARACTUAL

FLOOR OPENINGS AT

FRONT REAR

(QTY) (QTY)

WALL SIZE (FRONT) WALL SIZE (REAR) SILL TYPE

FRONT REAR

WHEEL LOAD

FRONT REAR

MISC.

FRONT REAR

OVERALL

FRAME

"B" DIM.

1-3,M DRYWALL 4 1/8" 6 3/8" 4 #4 STLS #4 STLS NICKEL 625 WELDED FRAMES, 16 GA DOORS

ROUGH OPENING

3 7/16"SILL LINE

DRYWALL TYPE FRAME

FACE FACE

5"

MIN.

3/4"

3 1/2"

"B"

1/16"

4 1/2"

R22" BELOW

EACH FLOOR

R1

(LBS.)

REACTIONS

R2 R1

ENTRANCE ELEVATION

INTERLOCK

KEYHOLE

ROUGH OPENING

9' -3

" R O

U G

H O

PE

N

IN

G

H

EI

G H

T

4'-9" ROUGH OPENING WIDTH

ONE SPEED LEFT HAND DOOR & ENTRANCE

ELEVATOR 1 (FRONT)

2" 2"3'-6" CLEAR OPENING

3'-6"3'-6"

9' -3

" R O

U G

H O

PE

N

IN

G

H

EI

G H

T

TOTAL WEIGHT OF CAR

& HALL DOOR = 443 LBS.

C

FINAL

GRAIN TO RUN THE LENGTH

OF THE PART UNLESS OTHERWISE NOTED

FOR: ELEV #

DRAWING NO. REV.DATE BRANCH

OF

DWN JOB NUMBER SHEET NO.

DATE

CITY:

ADDRESS:

GENERAL CONTRACTOR:

ELEVATOR CONTRACTOR:

DO NOT SCALE THIS DRAWING

BYSYM. REVISION

ARCHITECT:

CAB

This drawing and all information thereon is the proprietary property of TK Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and is not to be used directly or indirectly in any manner detrimental to the interest of TK Elevator.

NOTES

LAMINATE BACKING SHEETS. APPLIED PANELS ARE FACED

AND WRAPPED ON VERTICAL EDGES WITH

14 GAUGE #4 STAINLESS STEEL WALLS. REMOVABLE APPLIED

PANELS HAVE 3/4" PARTICLE BOARD CORES WITH 1/32"

CAB WALLS

14 GAUGE STEEL TOP, REINFORCED TO COMPLY WITH ASME A17.1

CODE. THE EXTERIOR IS PRIMED AND THE INTERIOR IS PAINTED

CAB TOP

WITH DOWN LIGHT RECEPTACLES AS REQUIRED.

THE DOWN LIGHT CEILING CONSISTS OF FORMED

SUSPENDED CEILING

LED

LIGHTING

FRONT RETURN AND TRANSOM

FOR DOOR OPERATOR. INTERIOR IS

16 GAUGE HOLLOW METAL REINFORCED AND DRILLED

CAB DOORS

CAB BASE

HANDRAILS

FAN

TOP EMERGENCY EXIT PROVIDED WITH CARTOP EXIT SWITCH.

EMERGENCY EXIT

PROTECTION PADS

PAD BUTTONS

CAB SILL

CAB FLOORING

/2 " S

TL

. P

AN

EL

" S

TL

. P

AN

EL

/2 " C

LE

AR

IN

SI

D E

ST

EE

L

SH

EL

L

" P

LA

TF

O R

M

3/

8"

1/ 8"

2"

2 1/2"

3/

1 1/2" 1 1/2"81" CLEAR INSIDE STEEL SHELL

84" PLATFORM

40 3/4" STL. PANEL

2" 2 1/8"24 1/4"

43 1/4" STL. PANEL

REMOVABLE APPLIED PANEL CAB DESIGN

SEE DETAIL "A"

SEE DETAIL "B"

DENVER, CO

JM1

EGK997

DESIGNED PER ASME A17.1

#4 STAINLESS STEEL

F-114 REFLECTIVE WHITE.

STAINLESS STEEL #4 PAN SECTIONS

COLUMN TYPE SWING.

STAINLESS STEEL W/ #4 BRUSH FINISH

STAINLESS STEEL W/ #4 BRUSH FINISH.

STAINLESS STEEL W/ #4 BRUSH FINISH

1/4" X 2" STAINLESS STEEL #4 REMOVABLE CONTINUOUS BAR.

TWO SPEED EXHAUST WITH STANDARD FAN GRILL.

PROTECTION PADS TO BE SUPPLIED.

PAD BUTTONS TO BE SUPPLIED.

EXTRUDED NICKEL SILVER.

FLOORING BY OTHERS.

10/06/22JM

EGK997Field

CBK9971 1 4

AIR FORCE CYBERWORX

STAINLESS STEEL

TO BE 316 SERIES

USAF ACADEMY

TKE DENVER

COLORADO SPRINGS, CO 80840-

TWO WAY COMMUNICATION (2019)

2 WAY COMMMUNICATION CAMERA. THIS IS ONE WAY STREAMING ONLY - TO BE FIELD MOUNTED

22 1/4" 1 1/2"

3 1/8"

12 1/8"3" 42" CLEAR OPENING

SWING RETURN

ONE SPEED LEFT HAND DOOR AT FRONT

C

FINAL

GRAIN TO RUN THE LENGTH

1 LAYER SOUND DEADENING SHEETS TO BE PROVIDED

OF

DWN JOB NUMBER SHEET NO.

DATE

CITY:

ADDRESS:

GENERAL CONTRACTOR:

ELEVATOR CONTRACTOR:

DO NOT SCALE THIS DRAWING

BYSYM. REVISION

ARCHITECT:

CAB

This drawing and all information thereon is the proprietary property of TK Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and is not to be used directly or indirectly in any manner detrimental to the interest of TK Elevator.5 1/2"

B

B

ELEVATION 2 & 4

RIGHT SIDE SHOWN

LEFT SIDE OPPOSITE

1/

8"

1 1/8" PANEL

7/8" PANEL

3/

8"

SECTION B-B

A

A

ELEVATION 1

C

C

ELEVATION 3

1 1/2" TYP. AT FRONT AND REAR

1 1/8" PANEL

7/8" PANEL

3/ 8"

F

IN

IS

H

ED

F

LO

O

R (T

YP

SECTION C-C

" T

O T

O P

O F

H

AN

D R

AI

L

1 1/2" TYP. AT SIDES

SE

E

D

ET

AI

L

"C

SE

E

D

ET

AI

L

"D

SE

E

D

ET

AI

L

"E

1"

PA

D

B U

TT

O

N 1"

PA

D

B U

TT

O

N

DENVER, CO

JM1

EGK997

DESIGNED PER ASME A17.1

/2 " A

PP

LI

ED

P

AN

EL

S

/8 " U

N D

ER

S

U

SP

EN

D

ED

C

EI

LI

N G

5/ 8"

T O

P O

F

SI

D E

W

AL

LS

5/ 8"

O

VE

R

AL

L R

EA

R

W

AL

LS

VENTILATION AS REQUIRED PER ASME A17.1 CODE

(SEE DETAIL F)

10/06/22JM

EGK997Field

CBK9972 2 4

AIR FORCE CYBERWORX

STAINLESS STEEL

TO BE 316 SERIES

USAF ACADEMY

TKE DENVER

COLORADO SPRINGS, CO 80840-

SWING

RETURN

SECTION A-A

1/ 4"

2 1/4"

1 1/4"

1/4"

4 5/8"

3/ 4"

3/ 8"

F

IN

IS

H

ED

F

LO

O

R (T

YP

5/ 8"

U N

D

ER

T O

P

/8 " U

N D

ER

S

U

SP

EN

D

ED

C

EI

LI

N G

1/

4"

C

LE

AR

O

PE

N

IN

G

C

FINAL

OF

DWN JOB NUMBER SHEET NO.

DATE

CITY:

ADDRESS:

GENERAL CONTRACTOR:

ELEVATOR CONTRACTOR:

DO NOT SCALE THIS DRAWING

BYSYM. REVISION

ARCHITECT:

CAB

This drawing and all information thereon is the proprietary property of TK Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and is not to be used directly or indirectly in any manner detrimental to the interest of TK Elevator.

81" CLEAR INSIDE STEEL SHELL

EMERGENCY EXIT

CEILING (REFLECTED VIEW)

CARTOP (REFLECTED VIEW)

/2 " O

.A . D

EP

TH

(C

LE

AR

IN

SI

D

E

ST

EE

L

SH

EL

L)

7/8"

82 3/4" O.A. WIDTH

7/8" 78" O.A. WIDTH

/2 " O

.A . D

EP

TH

DENVER, CO

JM1

EGK997

DESIGNED PER ASME A17.1

10/06/22JM

EGK997Field

CBK9973 3 4

AIR FORCE CYBERWORX

STAINLESS STEEL

TO BE 316 SERIES

USAF ACADEMY

TKE DENVER

COLORADO SPRINGS, CO 80840-

FAN GRILL

C

FINAL

OF

DWN JOB NUMBER SHEET NO.

DATE

CITY:

ADDRESS:

GENERAL CONTRACTOR:

ELEVATOR CONTRACTOR:

DO NOT SCALE THIS DRAWING

BYSYM. REVISION

ARCHITECT:

CAB

This drawing and all information thereon is the proprietary property of TK Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and is not to be used directly or indirectly in any manner detrimental to the interest of TK Elevator.

1 1/8"

1 1/8"

2 1/2"

2 1/2" AT

FRONT AND

REAR

7/8"

PLATFORM EDGE

DETAIL "A"

(TYP. CORNER)

PL

AT

FO

R

M E

D G

E

2" TYP.

ALL CENTERS

(TYP. PANEL JOINT)

DETAIL "B"

3/8" FINISHED FLOOR

5 1/8"

(TYP. FLOOR MTG. DETAIL)

DETAIL "C"

REMOVABLE PANEL

PANEL CLIP

STEEL

SHELL

SUB-FLOOR LINE

3/4" WOOD CORE

1/32" BACKING SHEET

1/32" BACKING SHEET

1/32" FACE SHEET

DETAIL "D"

(TYP. HANDRAIL AND ATTACHMENT)

HANDRAIL FINISH

HANDRAIL, SPACER AND WASHER

#4 STAINLESS STEEL

SEE PAGE 2 FOR

HEIGHT ABOVE FLOOR

1"

1 3/8"

1 1/2" TYP.

DOWNLIGHT

CEILING

DETAIL "E"

(TYP. CEILING MOUNTING)

SIDE WALL

MOUNTING ON SIDE

WALLS ONLY

.563

3" 1 1/2"

3 3/16" 1/4"

(TYP.)

1/4"

(TYP.)

C 7 3/16"

13 1/4"

14 3/8"

(TYP. VENT DETAIL)

DETAIL "F"

L 1/4" x 3" SLOTS

(27 TOTAL)

UNFINISHED FLOOR

Ø7/32"

(2 HOLES)

COLORADO SPRINGS, CO 80840-

DENVER, CO

JM1

EGK997

DESIGNED PER ASME A17.1

10/06/22JM

EGK997Field

CBK9974 4 4

AIR FORCE CYBERWORX

STAINLESS STEEL

TO BE 316 SERIES

USAF ACADEMY

TKE DENVER

B

FINAL

GRAIN TO RUN THE LENGTH

OF THE PART UNLESS OTHERWISE NOTED

1/4" 1 5/8"

2" 1"

1 3/8"

SYM.

ELEVATOR CONTRACTOR:

GENERAL CONTRACTOR:

DWN DATE

ARCHITECT:

ADDRESS:

CITY:

DATE

FOR:

DRAWING NO.JOB NUMBERBRANCH SHEET NO.REV.

OF

DO NOT SCALE THIS DRAWING

REVISION

ELEV #

BY

CAR SIGNAL

This drawing and all information thereon is the proprietary property of TK Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and is not to be used directly or indirectly in any manner detrimental to the interest of TK Elevator.

LA

TC

H A

C C

ES

S

.5

.0

[8

.0 0m m

.0

LEFT HAND PANEL

M

M

FIREFIGHTERS'

PUSH

STOP

RUN

PULLCANCEL

CALL

SMOKING

FIRE SERVICE-ANSI2016 WITH TWO WAY COMM

AN 8" X 8" DOOR TO MATCH CAR STATION FINISH. PANEL CONSIST OF FIRE

SERVICE DEVICES WITH FIRE INSTRUCTIONS INSIDE OF DOOR. "FIREFIGHTERS'

OPERATION" ON DOOR IS .438 HIGH RED LETTERS.

OPEN

NOF

OF

LOH D

F IR E OPE R.

CLOSE

FIREFIGHTERS'

OPERATION

NO

SMOKING

TEST

RESET

FO F

NO

DCAR

RER AE D

E

ND

S

I

ECRE IV

T

EN

ON

DPEN

SSACCE

LE

E

AB

N

OFF UR N

OTP

S

5.

1" [1

.5

0m m

CAR OPERATING STATION

KEY SWITCHES

THE KEY SWITCH CONSISTS OF A CHROME KEY CYLINDER MOUNTED IN

A 1 3/8"Ø BEZEL. THE GRAPHICS FOR THE KEY POSITIONS ARE PAD

PRINTED ON THE SURFACE OF THE BEZEL AND ARE COLORED WHITE.

ALARM AND FLOOR BUTTONS - V7 / V8 (WHITE)

THE PUSH-BUTTON CONSIST OF A 1 1/4"Ø HALO AROUND AN

ILLUMINATING 1 1/16"Ø CLEAR RING AND A 1"Ø BUTTON.

DOOR OPEN AND DOOR CLOSE BUTTONS - V7 / V8

THE PUSH-BUTTON CONSIST OF A 1 1/4"Ø HALO AROUND A

NON-ILLUMINATING 1 1/16"Ø CLEAR RING AND A 1"Ø BUTTON.

BRAILLE PLATES

1 1/2" DIAMETER CAST PLATES WITH WHITE CHARACTERS ON BLACK

BACKGROUND. MEETS ANSI A117.1 70% CONTRAST REQUIREMENTS.

MECHANICALLY FASTENED FROM BACK SIDE. INCLUDES ARABIC OR

N.E.I.I. DESIGNATIONS AND BRAILLE.

BRAILLE PLATE MOUNTING

MECHANICAL FASTENER

WHITE CHARACTER,

BLACK BACKGROUND

AND BRAILLE

SWING PANEL

EMERGENCY LIGHT

4 7/8" X 1 3/8" WINDOW MADE OF P-4 PLEXIGLAS.

EMERGENCY LIGHT WILL LIGHT CLEAR.

CARD READER PROVISIONS

4" x 4" AREA FOR CARD READER IS INCLUDED.

UNIT AND MOUNTING IS BY OTHERS.

ELEVATOR

CAPACITY 3500 LBS.

ELEVATOR

CAPACITY 3500 LBS.

CAPACITY PLATE

4 3/4" X 1 1/4" PLATE TO MATCH FACEPLATE

WITH BLACK TEXT. MECHANICALLY FASTENED

FROM BACK SIDE.

EMERGENCY

POWER

SILLAC DERE

AN S W

SETAIC

IN

D

IKIL N

B

NG

SILLAC DERE

ANS W

SETAIC

IN

D

IKIL N

B

NG

SPEAKER PHONE

CALL BUTTON MOUNTED IN A POLYCARBONATE PLAQUE WITH BRAILLE

AND WHITE RAISED SYMBOL AND CHARACTERS. MANDATED BUTTON

IDENTIFICATION TO MEET A17.1 CODE. COMPLETE PHONE WITH

SPEAKER INSTALLED BY TK ELEVATOR, MIDDLETON.

RETURN PANEL SKIN: STAINLESS STEEL W/ #4 BRUSH FINISH

CONTROLLER: TAC32

STATION: MAIN

TOTAL REQUIRED: 1

.0

EGK997

AIR FORCE CYBERWORX

USAF ACADEMY

COLORADO SPRINGS, CO 80840-

TKE DENVER

DENVER, CO

JM 10/06/22

EGK997Field

JM1 1 1CMK997

DESIGNED PER ASME A17.1

STAINLESS STEEL

TO BE 316 SERIES

15.250"

POSITION INDICATOR

MATISSE 10" [8.764" X 4.925" CUTOUT] FOR TWO

WAY COMMUNICATION. BLUE BACKGROUND WITH

3" WHITE TEXT.

7.

0"

5.

6"

GRAPHICS

"NO SMOKING" TO BE .625 HIGH

BLACK LETTERS.

FLUSH LOCKED COMPARTMENT

7" X 11" DOOR THAT MATCHES THE CAR STATION

FINISH. THE DOOR IS LOCKED WITH A 7 PIN ACE LOCK.

DEVICES ARE MOUNTED BEHIND ON A SUBPLATE.

GRAPHICS

ELEV.# TO BE .500" HIGH BLACK LETTERS.

CAPACITY TO BE .250" HIGH BLACK LETTERS.

CAPACITY 3500 LBS.

ELEVATOR 1

CERTIFICATE WINDOW

4" X 8" FLUSH MOUNTED PLEXIGLAS.

CARD READER PROVISIONS

A 4" X 4" PLEXIGLASS WINDOW WILL BE SUPPLIED. UNIT AND ALL

MOUNTING PROVISIONS WILL BE BY OTHERS.

EMERGENCY

POWER

TEST

RESET

FO F

NO

DCAR

RER AE D

E

ND

S

I

ECRE IV

T

EN

ON

DPEN

SSACCE

LE

E

AB

N

OFF UR N

OTP

S

C

FINAL

GRAIN TO RUN THE LENGTH

OF THE PART UNLESS OTHERWISE NOTED

SMART RESCUE PHONE

SMART RESCUE PHONE FOR 1-5 CARS TO BE PROVIDED MALE VOICE

2) LANDING ANNUNCIATION VERBIAGE (PLEASE PRINT)

* PLEASE SPECIFY BELOW FOR VOICE ANNUNCIATOR

1) PLEASE SELECT

FEMALE VOICE

FLOOR 1 FLOOR 1

FLOOR P FLOOR P

FLOOR 2 - 4 FLOOR 2, FLOOR 3, ETC.

VOICE ANNUNCIATOR

VOICE ANNUNCIATOR WILL BE MOUNTED BEHIND

3.5" [89] SPEAKER PATTERN.

ELEVATOR CONTRACTOR:

ARCHITECT:

BYREVISIONSYM.DATE

DO NOT SCALE THIS DRAWING

This drawing and all information thereon is the proprietary property of TK Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and is not to be used directly or indirectly in any manner detrimental to the interest of TK Elevator.

REV.JOB NUMBERDWN DATE BRANCH DRAWING NO.

GENERAL CONTRACTOR:

CITY:

ADDRESS:

FOR: ELEV #

OF

SHEET NO.

HALL SIGNAL

HALL STATIONS

FACEPLATE

TYPE:

FINISH:

MTG. HARDWARE:

B REZU Z

ES

RE

T

NOPH E

ELEVATOR

COMMUNICATIONS

FAILURE

COMMUNICATION

FAILURE

E NO

S

RE

T

FOF

FIRE RECALL

FIRE KEY AND TURN TO "ON"

TO RECALL ELEVATORS INSERT

FIREFIGHTERS' OPERATION

1/

4" [5

7.

m m

3/ 4"

[4 4.

m m

5/

8" [6

6.

m m

3/ 4"

[4 4.

m m

3/

4" [4

4.

m m

[6

.6 0m m

7" [177.80mm]

AT FLOOR:

ELEVATOR NO.:

TOTAL REQUIRED:

1/

4" [5

7.

m m

3/ 4"

[4 4.

m m

[3

.6 0m m

7" [177.80mm]

AT FLOOR:

ELEVATOR NO.:

TOTAL REQUIRED:

1/

8" [7

9.

m m

[3

.6 0m m

7" [177.80mm]

AT FLOOR:

ELEVATOR NO.:

TOTAL REQUIRED:

USE ONLY

EMERGENCY

FIRE DEPT.

AND

KEY

ELEVATOR

FOR

3 1/2" [88.90mm]

[2

.0 0m m

AT FLOOR:

ELEVATOR NO.:

TOTAL REQUIRED:

USE ONLY

FIRE DEPARTMENT

7" [1

.8

0m m

[2

.4

0m m

2"

2"

6" [152.40mm]

2"

10" [254.00mm]

2"

AT FLOOR:

ELEVATOR NO.:

TOTAL REQUIRED:

CUTOUT MOUNTING DATA - HALL STATIONS

FACEPLATE: 7"(177.80mm)W x 14"(355.60mm)H WITH MTG. HARDWARE: 5"(127.00mm)W x 12 1/8"(307.98mm)H O.C.

BOX: 6 1/16"(153.99mm)W x 13"(330.20mm)H X 2 1/2"(63.50mm)D CUTOUT: 6 3/16"(157.16mm)W x 13 1/8"(333.38mm)H

CUTOUT MOUNTING DATA - HALL STATIONS

FACEPLATE: 7"(177.80mm)W x 24"(609.60mm)H WITH MTG. HARDWARE: 5"(127.00mm)W x 22 1/8"(561.98mm)H O.C.

BOX: 6 1/16"(153.99mm)W x 23"(584.20mm)H X 2 1/2"(63.50mm)D CUTOUT: 6 3/16"(157.16mm)W x 23 1/8"(587.38mm)H

CUTOUT MOUNTING DATA - EMERG. KEY BOX

FACEPLATE: 3 1/2"(88.90mm)W x 10"(254.00mm)H WITH MTG. HARDWARE AT 8 5/16"(211.15mm) O.C.

BOX: 2 3/4"(69.85mm)W x 9"(228.60mm)H X 1 7/8"(47.63mm)D CUTOUT: 2 7/8"(73.03mm)W x 9 1/8"(231.78mm)H

WINDOW

2 1/4" X 2 1/4" GLASS WINDOW WITH BLACK

LETTERING.

CUTOUT MOUNTING DATA - FIRE KEY BOX

FACEPLATE: 10"(254.00mm)W x 11"(279.40mm)H WITH MTG. HARDWARE: 8 1/16"(204.80mm)W x 9 1/16"(230.20mm)H O.C.

BOX: 9 1/8"(231.78mm)W x 9 3/4"(247.65mm)H X 4"(101.60mm)D CUTOUT: 9 1/4"(234.95mm)W x 9 7/8"(250.83mm)H

GRAPHICS

1/4" HIGH, COLORED RED.

FIRE SERVICE - ANSI2016

1 3/8" DIA. RED BEZEL WITH WHITE LETTERING.

KEY IS REMOVABLE IN "OFF" & "ON" POSITIONS.

KEY IS NOT REMOVABLE IN "RESET" POSITION.

1 3/8" DIA. BEZEL, 1" DIA. BLACK JEWEL, AND

1 1/4" DIA. HALO. HALO AND FIRE HAT

ILLUMINATE RED.

METAL BUTTONS - V7 / V8 (WHITE)

1 1/4" DIA. HALO AROUND AN ILLUMINATING

1 1/16" DIA. CLEAR RING AND A

1" DIA. BUTTON

PICTOGRAPH ENGRAVED

FIRE FLAME IS COLORED SOLID RED. CIRCLES, SLASHES,

AND SYMBOLS TO BE BLACK ON WHITE BACKGROUND.

ALL LETTERING TO BE BLACK.

ENGRAVING

TITLES ARE 1/4"H, 3/16"H INSTRUCTIONS. ALL

COLORED RED. HELVETICA MEDIUM LETTERING.

COMBINATION P.I./HALL LANTERNS

FACEPLATE

TYPE:

FINISH:

MTG. HARDWARE:

AT FLOOR:

ELEVATOR NO.:

TOTAL REQUIRED:

19 3/8" [492.13mm]

1/

2" [1

.3

0m m

CUTOUT MOUNTING DATA

FACEPLATE: 19 3/8"(492.13mm)W x 4 1/2"(114.30mm)H WITH MTG. HARDWARE AT 17 7/16"(442.91mm) O.C.

BOX: 18 1/8"(460.38mm)W x 3 3/4"(95.25mm)H x 2 1/2"(63.50mm)D CUTOUT: 18 1/4"(463.55mm)W x 3 7/8"(98.43mm)H

CHIME

AN INTERNALLY MOUNTED ADJUSTABLE CHIME SOUNDS

SIMULTANEOUSLY WITH ILLUMINATION OF A LANTERN.

CHIME SOUNDS ONCE FOR UP, TWICE FOR DOWN.

LANTERNS

2 1/2" x 2 1/2" WHITE LEXAN PLASTIC LENSES

WHICH ILLUMINATE UPON CAR ARRIVAL TO

INDICATE DIRECTION OF TRAVEL.

ILLUMINATION:

POSITION INDICATOR (BLUE)

THE POSITION INDICATOR CONTAINS

5x7 DOT MATRIX DISPLAYS.

DISPLAY TO READ:

EGK997

AIR FORCE CYBERWORX

USAF ACADEMY

COLORADO SPRINGS, CO 80840-

TKE DENVER

DENVER, CO

JM 10/06/22

EGK997Field

JM1 HFK997 1 1

DESIGNED PER ASME A17.1

STAINLESS STEEL

TO BE 316 SERIES

VERTICAL

11 GAUGE STAINLESS STEEL W/ #4 BRUSH FINISH

SPANNER HEAD SCREWS

KEYSWITCH FINISH: CHROME

2,3

M

HORIZONTAL

11 GAUGE STAINLESS STEEL W/ #4 BRUSH FINISH

SPANNER HEAD SCREWS

GREEN FOR UP, RED FOR DOWN

1-3,M

OD

UP

FO F

SSACCE

NW

1/

2" [1

.3

0m m

9" [2

.6

0m m

3 1/2" [88.90mm]

AT FLOOR:

ELEVATOR NO.:

TOTAL REQUIRED: 2

1,M

CUTOUT MOUNTING DATA - HALL STATIONS

FACEPLATE: 3 1/2"(88.90mm)W x 9"(228.60mm)H WITH MTG. HARDWARE AT 7 3/16"(182.56mm) O.C.

BOX: 2 3/4"(69.85mm)W x 8"(203.20mm)H x 2 1/2"(63.50mm)D CUTOUT: 2 7/8"(73.03mm)W x 8 1/8"(206.38mm)H

C

AT FLOOR:

ELEVATOR NO.:

TOTAL REQUIRED:

19 3/8" [492.13mm]

1/

2" [1

.3

0m m

AT FLOOR:

ELEVATOR NO.:

TOTAL REQUIRED:

19 3/8" [492.13mm]

1/

2" [1

.3

0m m

2,3

M

FINAL

GRAIN TO RUN THE LENGTH

OF THE PART UNLESS OTHERWISE NOTED

Elevators Are Out Of Service

Use Exit

In Case Of Fire Elevators Are Out Of Service

Use Exit

In Case Of Fire

Elevators Are Out Of Service

Use Exit

In Case Of Fire

Appendix 5 Elevator Dimensions
14 24 23-1.4 Elevator Layout Drawings AIR FORCE CYBERWORX - Rev2
BCI Submittal Cover Page
Text1#1: Hydraulic Passenger Elevator
Text2#1: 14 24 23
Text3: 14 24 23-1.4
Text4: 14 24 23
Text7: Terri Napier
Text6: 5/5/2023
Check Box1: Yes
Check Box2: Off
Check Box3: Off
Check Box4: Off
Text5: W9128F22C0025
<<CabColorInfo2>>: CAB FLOORING THICKNESS:
<<CabType1>>: CAB TYPE:
<<CabType2>>: CAB PANEL:
<<CabType3>>: REVEALS:
<<CabType4>>: BASE:
<<CabType5>>: CAB CEILING:
<<CabType6>>: CAB CEILING FINISH:
<<CabType7>>: CAB DOOR:
<<CabType8>>: CAB SILLS:
<<CabType9>>: CAB HANDRAIL(S):
<<CabType10>>: HANDRAIL(S) FINISH:
<<CabType11>>: CAB PROTECTION:
CabTypeFeature1-: APPLIED PANEL
CabTypeFeature2-: #4 316 STAINLESS
CabTypeFeature3-: #4 316 STAINLESS
CabTypeFeature4-: #4 316 STAINLESS
CabTypeFeature5-: DOWN LIGHT - METAL PAN CEILING
CabTypeFeature6-: #4 316 STAINLESS
CabTypeFeature7-: #4 316 STAINLESS
CabTypeFeature8-: NICKEL SILVER
CabTypeFeature9-: (3) 1/4" x 2" CONTINUOUS FLAT BAR
CabTypeFeature10-: #4 316 STAINLESS
CabTypeFeature11-: PAD BUTTONS PROVIDED (1) PADS
PrimaryFireServiceFloor2-: 1
FloorMarkings1-: M
FloorMarkings2-: 3
FloorMarkings3-: 2
FloorMarkings4-: 1
Wall Thickness1-: 4 1/8"
Wall Thickness2-: 4 1/8"
Wall Thickness3-: 4 1/8"
Wall Thickness4-: 4 1/8"
Entrance Door Finish1-: #4 Stainless
Entrance Door Finish2-: #4 Stainless
Entrance Door Finish3-: #4 Stainless
Entrance Door Finish4-: #4 Stainless
Entrance Frame Finish1-: #4 Stainless
Entrance Frame Finish2-: #4 Stainless
Entrance Frame Finish3-: #4 Stainless
Entrance Frame Finish4-: #4 Stainless
AlternateFireServiceFloor-: 2
PushButtonIllumination1-: VANDAL RESISTANT LED COLOR:
PositionIndicatorIllumination1-: POSITION INDICATOR ILLUM:
<<CabColorInfo1>>: CAB FLOORING WEIGHT LBS:
field_1: 150 lbs
field_2: 3/8"
field_3: WHITE LED
Wall Type1-: Drywall
Wall Type2-: Drywall
Wall Type3-: Drywall
Wall Type4-: Drywall
field_4: Blue

File details come from the government source that posted it. Updated .