This file comprises Appendices A and B for a Request for Proposals issued by the City of Long Beach Public Utilities Department in California for an Arc Flash Study of All Off-Site Facilities. The RFP seeks proposals from experienced and licensed consultant firms to conduct a comprehensive arc flash study across all off-site facilities operated by the department. The appendices serve as the data sheet and facilities list necessary for bidders to understand the scope and scale of the project, providing essential information regarding facility locations, electrical system characteristics, and technical requirements that consultants must address in their proposals.
The file appears to be an Excel spreadsheet containing detailed facility information and technical data required for proposal development. This documentation enables qualified bidders to assess project complexity, conduct accurate cost estimations, and develop methodologically sound study approaches. Prospective contractors should review both the facilities list and technical data specifications carefully to ensure their proposals comprehensively address all off-site facilities within the study scope and meet the City of Long Beach Public Utilities Department's technical and professional licensing requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Appx A - Data Sheet
| No. | Data Category | Field Data to Collect | Data Source |
| 1 | Utility Source Information | Utility short-circuit capacity and X/R ratio at the point of service or power delivery point, including three-phase fault and line-to-ground fault values. | SCE to Provide |
| 2 | Utility-Owned Transformer Information | Transformer capacity, primary and secondary voltage ratings, impedance, winding connection, and available tap information, where the transformer is owned or maintained by SCE. | SCE to Provide |
| 3 | Utility Service Conductors | Service conductor size, material/type, length or impedance, number of conductors per phase, and conduit type, where the conductors are owned, installed, or maintained by SCE. | SCE to Provide |
| 4 | Utility Overhead Service Information | Overhead line impedance or conductor data, line configuration, conductor size/type, phase spacing, and approximate length, where applicable to SCE-owned overhead service. | SCE to Provide |
| 5 | Point of Service / Power Delivery Point | Confirmation of the service point, utility demarcation point, metering arrangement, and any SCE-side equipment relevant to the arc flash or power system study. | SCE to Provide |
| 6 | Existing Electrical Drawings | System one-line diagrams, if available, showing major equipment such as transformers, motors, circuit breakers, fuses, relays, panels, MCCs, switchgear, and generators. | LBUD to Provide |
| 7 | LBUD-Owned Transformers | Transformer capacity, voltage ratings, tap position, impedance, and winding connection for transformers owned or maintained by LBUD. | LBUD to Provide |
| 8 | Facility Cables and Conductors | Cable length or impedance, conductor size, conductor material/type, insulation type if available, number of conductors per phase, cable configuration, and conduit type for LBUD-side conductors. | LBUD to Provide |
| 9 | Large Motors and Generators | Ratings of all large motors and generators, including horsepower/kW, voltage, full-load amps, service factor, starter type, and nameplate information. | LBUD to Provide |
| 10 | Medium- and High-Voltage Circuit Breakers | Manufacturer, type/model, voltage rating, continuous current rating, interrupting rating, relay/control information, and other applicable ratings. | LBUD to Provide |
| 11 | Low-Voltage Circuit Breakers | Manufacturer, type/model, frame rating, trip rating, interrupting rating, trip unit manufacturer and type, existing settings, and sensor or plug rating. | LBUD to Provide |
| 12 | Molded Case Circuit Breakers and Panels | Short-circuit current ratings of panels and molded case circuit breakers located within panels, including SCCR/AIC ratings. | LBUD to Provide |
| 13 | Protective Relays | Relay type, range, manufacturer, style/model number, existing settings, and current transformer ratio. | LBUD to Provide |
| 14 | Fuses | Fuse manufacturer, type/class, ampere rating, voltage rating, interrupting rating, and currently installed fuse size. | LBUD to Provide |
| 15 | Surge Arresters | Surge arrester ratings, type, and locations. | LBUD to Provide |
| 16 | Power Factor Correction Capacitors | Capacitor ratings and connection configuration, including kVAR, voltage rating, phase connection, and switching/control method, if available. | LBUD to Provide |
| 17 | Reactors | Reactor impedance, voltage rating, current rating, application, and location. | LBUD to Provide |
Appx B -Offsite Facilities List
| No. | Facility Type | LBUD Facility Names | Voltage | Number of Phases |
| 1 | Sewer Lift Station | S-1 | 480 | 3 |
| 2 | Sewer Lift Station | S-2 | 480 | 3 |
| 3 | Sewer Lift Station | S-3 | 480 | 3 |
| 4 | Sewer Lift Station | S-4 | 240 | 3 |
| 5 | Sewer Lift Station | S-5 | 240 | 3 |
| 6 | Sewer Lift Station | S-6 | 480 | 3 |
| 7 | Sewer Lift Station | S-7 | 240 | 3 |
| 8 | Sewer Lift Station | S-8 | 480 | 3 |
| 9 | Sewer Lift Station | S-9 | 480 | 3 |
| 10 | Sewer Lift Station | S-10 | 480 | 3 |
| 11 | Sewer Lift Station | S-11 | 240 | 3 |
| 12 | Sewer Lift Station | S-12 | 480 | 3 |
| 13 | Sewer Lift Station | S-14 | 240 | 3 |
| 14 | Sewer Lift Station | S-15 | 240 | 3 |
| 15 | Sewer Lift Station | S-16 | 240 | 3 |
| 16 | Sewer Lift Station | S-17 | 208 | 3 |
| 17 | Sewer Lift Station | S-18 | 480 | 3 |
| 18 | Sewer Lift Station | S-19 | 480 | 3 |
| 19 | Sewer Lift Station | S-20 | 240 | 3 |
| 20 | Sewer Lift Station | S-21 | 240 | 3 |
| 21 | Sewer Lift Station | S-22 | 240 | 3 |
| 22 | Sewer Lift Station | S-23 | 240 | 3 |
| 23 | Sewer Lift Station | S-25 | 480 | 3 |
| 24 | Sewer Lift Station | S-26 | 480 | 3 |
| 25 | Sewer Lift Station | S-29 | TBD | TBD |
| 26 | Sewer Lift Station | S-30 | 480 | 3 |
| 27 | Sewer Lift Station | S-31 | 480 | 3 |
| 28 | Groundwater Well | Commission 10 | 480 | 3 |
| 29 | Groundwater Well | Commission 14 | 480 | 3 |
| 30 | Groundwater Well | Commission 15 | 480 | 3 |
| 31 | Groundwater Well | Commission 16 | 480 | 3 |
| 32 | Groundwater Well | Commission 17 | 480 | 3 |
| 33 | Groundwater Well | Commission 18 | 480 | 3 |
| 34 | Groundwater Well | Commission 19 | 480 | 3 |
| 35 | Groundwater Well | Commission 20 | 480 | 3 |
| 36 | Groundwater Well | Commission 21 | 480 | 3 |
| 37 | Groundwater Well | Commission 22A | 480 | 3 |
| 38 | Groundwater Well | Commission 24 | 480 | 3 |
| 39 | Groundwater Well | Commission 25 | 480 | 3 |
| 40 | Groundwater Well | North Long Beach 11 | 480 | 3 |
| 41 | Groundwater Well | North Long Beach 12 | 480 | 3 |
| 42 | Groundwater Well | North Long Beach 13 | 480 | 3 |
| 43 | Groundwater Well | North Long Beach 14 | 480 | 3 |
| 44 | Groundwater Well | Citizens 7A | 480 | 3 |
| 45 | Groundwater Well | Citzens 9 | 480 | 3 |
| 46 | Groundwater Well | Citzens 10 | 480 | 3 |
| 47 | Groundwater Well | Development 5 | 480 | 3 |
| 48 | Groundwater Well | Development 9 | 480 | 3 |
| 49 | Groundwater Well | Alamitos 8 | 480 | 3 |
| 50 | Groundwater Well | Alamitos 13 | 480 | 3 |
| 51 | Groundwater Well | Wilson 1A | 480 | 3 |
| 52 | Groundwater Well | Wise 1A | 480 | 3 |
| 53 | Groundwater Well | West Coast Basin 1/ Delta 1 | 480 | 3 |
| 54 | Reclaimed Water System | South Lake | 480 | 3 |
| 55 | Reclaimed Water System | El Dorado Booster Pump Station | 480 | 3 |
| 56 | Reclaimed Water System | El Dorado Backup Pump Station | 480 | 3 |
| 57 | Reclaimed Water System | Virginia Lake | 480 | 3 |
| 58 | Miscellaneous | J. Will Johnson Reservoir | 480 | 3 |
| 59 | Miscellaneous | 32nd Street Booster Pump Station | 480 | 3 |
| 60 | Miscellaneous | Parcel 9 | TBD | TBD |
| 61 | Miscellaneous | Operations Service Center (OSC) Yard | 480 | 3 |
| 62 | Miscellaneous | Operations Service Center (OSC) Yard Expansion | 480 | 3 |
| 63 | Miscellaneous | LBPUD Administration Building | 208 | 3 |
| 64 | Miscellaneous | Well 1017 | TBD | TBD |
| 65 | Miscellaneous | Gas Campus | 480 | 3 |
| 66 | Miscellaneous | Metropolitan Water District (MWD) Long Beach 5 Connection - 70th & Atlantic | 240 | 3 |
| 67 | Miscellaneous | Metropolitan Water District (MWD) Long Beach 7 Connection | 240 | 3 |
| 68 | Miscellaneous | MWD LB 3 Connection | TBD | TBD |