Amendment 1 - K13635 Q&A.pdf
PDF 882 KB Posted
- Attached to
- TWO 34-PASSENGER PRISONER TRANSPORT MODULES
- Solicitation number
- K13635
- Issued by
- Adams County, Asotin County, Benton County, Chelan County, Clallam County, Clark County, Columbia County, Cowlitz County, Douglas County, Ferry County, Franklin County, Garfield County, Grant County, Grays Harbor County, Island County, Jefferson County, King County, Kitsap County, Kittitas County, Klickitat County, Lewis County, Lincoln County, Mason County, Okanogan County, Pacific County, Pend Oreille County, Pierce County, San Juan County, Skagit County, Skamania County, Snohomish County, Spokane County, Stevens County, Thurston County, Wahkiakum County, Walla Walla County, Whatcom County, Whitman County, Yakima County, Asotin City, Clarkston City, Clarkston Heights-Vineland CDP, West Clarkston-Highland CDP, Benton City, Chelan City, Chelan Falls CDP, Clallam Bay CDP, Lewisville CDP, Rock Island City, Pacific Beach CDP, Whidbey Island Station CDP, Mercer Island City, Pacific City, Bainbridge Island City, Kingston CDP, Kitsap Lake CDP, Kittitas City, Klickitat CDP, Okanogan City, Anderson Island CDP, Fort Lewis CDP, Fox Island CDP, Herron Island CDP, Ketron Island CDP, North Fort Lewis CDP, Raft Island CDP, Stevenson City, Hat Island CDP, Lake Stevens City, Snohomish City, Spokane City, Spokane Valley City, Puget Island CDP, Garfield Town, Yakima City, Washington
About this file
This document outlines a Request for Proposal (RFP) issued by the Washington State Department of Corrections (DOC) for two 30-34 passenger prisoner transport modules. DOC will separately procure the chassis, so bidders are not required to submit a chassis as part of their proposal. The modules must be delivered no later than May 31, 2026. The RFP includes detailed specifications for the module design, including requirements for compartments, seating, security features, electrical systems, and other technical details. It also addresses insurance requirements, warranty terms, and other contractual terms.
The RFP is open to bidders across multiple jurisdictions in the state of Washington, including counties, cities, and census-designated places. The RFP does not specify a funding source, but the modules are intended for use by the DOC. Bidders are requested to provide pricing information and address any set-aside requirements. The RFP also includes instructions for submitting questions and clarifications during the bidding process.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| EXHIBIT H - Contract Model.pdf | ||
| EXHIBIT H(1) - General Terms and Conditions.pdf | ||
| EXHIBIT B - Bidder Profile Form.docx | DOCX document | |
| EXHIBIT G - Issues List.docx | DOCX document | |
| EXHIBIT D - Cost Proposal.docx | DOCX document | |
| EXHIBIT E - Certification of Bid.docx | DOCX document | |
| EXHIBIT F - Subcontractor Inclusion Plan.docx | DOCX document | |
| EXHIBIT A - Certification and Assurances.pdf | ||
| EXHIBIT C - Business Requirements Form.docx | DOCX document | |
| EXHIBIT C(1) - Prisoner Transport Module Reqs.docx | DOCX document | |
| RFP K13635.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions and Answers for
Washington State DOC
RFP K13635
Page Section Text
DOC went out to bid with similar specifications back in 2023, why are you going out to bid again?
The legislature provided funding for additional vehicles, so we need to go back out to bid.
1 Exhibit C(1), 1.3
ʺBidder shall warrant new modules against defective workmanship and materials for a period of at least five years from the date of acceptance."
We offer a Lifetime Module Warranty, a 2 year/30,000 mile conversion warranty (material and workmanship), a 5 year paint limited warranty, and a 7 year/75,000 miles limited electrical warranty(Workmanship/harnesses/connectors). Are these warranties acceptable?
Acceptable
Exhibit
C(1), 2.1
“DOC will supply (2) 2025 Freightliner M2-106 Crew Cab conventional, suitable for this application.
•Wheelbase - 313" •Cab to Axle- 198"200” •GVWR – 35,320 lbs.
•Cummings L9 260 HP Diesel Engine”
To verify details/compatibility of the chassis with the proposed module, we request a copy of the Freightliner M2-106 Crew Cab chassis quote, please. We request the that the Cab-to-axle be changed from 198” to 200”, to provide a 4” gap between the back of cab and the front of the module.
We’re waiting on the 2025 approved DES quote from Freightliner. We will adjust to the 200” assuming they can accommodate.
Exhibit
C(1), 2.2
“Install a U-bolt driveline guard.”
Is a Freightliner OEM driveline guard acceptable?
Acceptable
Exhibit
C(1), 2.2
“On-Spot brand automatic chains shall be installed on the rear axle of Chassis.”
Are OEM-installed OnSpot auto chains acceptable?
Acceptable
Exhibit
C(1), 2.2
“Install (2) Santa Cruz Gunlocks. This should be a vertical floor mounted system in the driver side rear compartment of the cab. Must be able to hold (2) AR15s (1) 12 gauge shotgun and (1) 40mm Launcher.”
Santa Cruz gun locks are designed to secure one weapon at a time. Are four gun locks desired?
Appears they do offer a dual or Double gun lock. We require two doubles or 4 singles to accommodate the weapons listed above.
Exhibit
C(1), 2.2
“A 9” frame extension shall be welded to each OEM frame rail to provide rear lateral and bumper support and to provide a step height of 12.5” from the bumper to the module floor.”
WA-DOC’s current 34 passenger PT being built has 11”H frame extensions to provide a shorter 7.6875” step from the bumper to the module floor…ok to change to 11”H to match?
Acceptable
Exhibit
C(1), 2.2
“OEM exhaust shall be routed from right rail location to left side, exiting just forward of the rear wheels.”
Would it be acceptable if the exhaust was ordered to terminate forward of the rear wheels, from Freightliner?
C(1), 3.4
“MODULE EXTERIOR COMPARTMENTS
The compartments are streetside and curbside and dimensions to be agreed upon by DOC and the approved Bidder…
Would it be acceptable to update the module compartment layout/dimensions to the following, to match WA-DOC’s latest 34 passenger PT currently being built (including eleven compartments total)?
C(1), 3.6-3.11
“Door(s) - 2" pan Aluminum, bottom hinged door with deadbolt.”
Please confirm that deadbolt locks are needed on all compartments?
Deadbolts are required.
Exhibit
C(1), 3.15
"The inside of the punched portion of the door – expect for 10” kept open at the bottom for ventilation – shall be covered with 0.1875” polycarbonate.”
Is thicker 0.25” clear polycarbonate acceptable?
C(1), 3.15
“COMPARTMENT No. 1, 2, 3, 9 (Isolation Cells) Dimensions- 22"W x 78"H x 34"D Location – Cells 1, 2, 3 streetside, aisle facing. Cell 9 curbside, aisle facing.
Interior Door – 20” W x 76”H Cell Door(s) – Doors shall be made of 0.123” hex punched aluminum. The inside of the punched portion of the door – expect for 10” kept open at the bottom for ventilation – shall be covered with 0.1875” polycarbonate. Door shall have a deadbolt-locked handcuff door made of punched aluminum with 0.1875:
polycarbonate covering the inside of the punched portion with a single-sided Schlage deadbolt lock. Door shall have a stainless-steel piano hinge with thread locking product applied to the hinge screws; shall have the hinge on the aft side of the door.
Seating - one (1) Bench seat, facing aisle Additional Instructions – 1.A camera in a recessed pocket, shall be installed in these cells. Four (4) cameras total specifically for the isolation cells with one (1) camera in each cell.
Aisle Doors(s) - Four.
COMPARTMENT No. 4 & 8 (Isolation Cells) Dimensions- 31.75"W x 78"H x 34"D Location – Cells 4 streetside, forward. Cell 8 curbside, forward.
Interior Door – 20” W x 76”H Cell Door(s) – Doors shall be made of 0.123” hex punched aluminum. The inside of the punched portion of the door – expect for 10” kept open at the bottom for ventilation – shall be covered with 0.1875” polycarbonate. Door shall have a deadbolt-locked handcuff door made of punched aluminum with 0.1875:
polycarbonate covering the inside of the punched portion with a single-sided Schlage deadbolt lock. Door shall have a stainless-steel piano hinge with thread locking product applied to the hinge screws; shall have the hinge on the aft side of the door.
Seating - one (1) Bench seat, facing forward Additional Instructions – A camera in a recessed pocket, shall be installed in these cells.
An 18.75” x 11.25” horizontal window with fixed glass shall be installed on the module wall. Window shall have 14 ga. Hex-punched stainless-steel cover riveted in place over the inside surface.
Aisle Doors(s) - Two.
Compartment No. 5 (Open Seating Area) Dimensions – 178.5” W x 78”H x 100” D Location – Streetside and curbside, center Seating – Twelve (12) Freedman bench seats, facing forward Additional Instructions – Eleven (11) Freedman Seating #CITI-36223-2PRIG gray 36” W two-person prison bench seats with mounting hardware shall be installed in this cell, six streetside and five curbside.
Nine (9) 18.75” x 11.25” windows with fixed glass shall be installed, five streetside and four curbside.
Windows shall have 14 ga. Hex-punched stainless-teel covers riveted in place over the inside surface.
A 25.125” W locking door made of 0.125” hex punched aluminum shall be installed between this cell and Cell #6; door shall have double-sided Schlage deadbolt lock.
HVAC units shall be in an upper closeout, ceiling level; one streetside and one curbside. UV-C filtering is desired.
Two (2) cameras, each in a recessed pocket, shall be installed in the ceiling of this cell; one forward facing and one aft facing.
Would it be acceptable to update the cell configuration to match the current WA-DOC 34 passenger PT build, 4092-5?
Compartment No. 6 (Rear Cell) Dimensions – 97” W x 78”H x 28.875” D
Location – Rear Seating – Two (2) 34”L x 10” D padded flip-up benches, each with spring-loaded seat irons to keep the bench in the upright position except during use. Non-padded aluminum benches are acceptable.
Additional Instructions – Benches shall be full depth with seating for two persons each.
A 25.125” W locking door made of 0.125” hex punched aluminum shall be installed between this cell and Cell #6; door shall have double-sided Schlage deadbolt lock.
One (1) camera in a recessed pocket, shall be installed in the ceiling of this cell; upper streetside forward corner.
Would it be acceptable to update the cell layout /dimensions to the following, to match WA-DOC’s latest 34 passenger PTs currently being built? Proposed cell layout below:
Streetside cells:
Curbside cells:
Plan view:
C(1), 3.15
“Compartment No. 6 (Rear Cell) Dimensions – 97” W x 78”H x 28.875” D Location – Rear Seating – Two (2) 34”L x 10” D padded flip-up benches, each with spring-loaded seat irons to keep the bench in the upright position except during use. Non-padded aluminum benches are acceptable.
Additional Instructions – 1.Benches shall be full depth with seating for two persons each.
2.A 25.125” W locking door made of 0.125” hex punched aluminum shall be installed between this cell and Cell #6; door shall have double-sided Schlage deadbolt lock.”
Note: Is the door to be between Cells #5 and 6?
Yes
Exhibit
C(1), 3.16
“Doors shall be made of 0.123” hex punched aluminum”
Are doors made of 0.125” aluminum acceptable?
Acceptable
Exhibit
C(1), 3.18
“Two (2) cameras, each in a recessed pocket, shall be installed in the ceiling of this cell; one forward facing and one aft facing.”
To obtain optimal viewing angles, is it acceptable to move cameras to the upper corners of cells (rather than the ceiling), where needed?
Acceptable
Exhibit
C(1) 3.19
What is the preferred orientation of the toilet?
Facing the isle.
Exhibit
C(1) 3.19
We typically install AC condensers in corners for easy serviceability but there appears to be a conflict with storage space.
Maximizing storage space takes precedence
Exhibit
C(1) 3.19
Section 3.19 requires a window, does that present a privacy concern?
From looking at previous SOW and contract, it seems to reference a half-door for the lavatory to provide some privacy. I think the key is some privacy so others cannot see the individual unclothed. I would suggest a half door high enough block the view from individuals sitting across from it. No internal window in the lavatory is necessary.
C(1), 3.19
“A Microphor #LF-3230 12 VDC stainless steel toilet with push button flush shall be installed in this area.”
Note: Microphor’s part number for their toilet is “LF-320”. We request for the bid to be amended.
Acceptable for part number LF-320. Needs to be a sitting toilet, not a urinal.
Exhibit
C(1), 3.19
“An 18/75: x 11/25: horizontal window with fixed glass shall be installed on the module wall.”
To clarify…this is an 18.75”W x 11.25”H window, correct?
Yes
Exhibit
C(1), 3.19
“A footwell incursion (for the forward curbside bench seat in Cell #5) shall be located on the aft wall.”
Because of limited space in the lavatory, is it acceptable to offer foot space below the bench seat instead?
Proposed:
C(1), 3.20
“A recessed double step doorstep shall be provided which is 19" deep x 31" wide at-the curbside passage door.”
Due to the presence of drop skirting, a 28”D triple stepwell with 7.375”H steps is required. Is this acceptable? Acceptable
Exhibit
C(1), 4.7
“No additional tint to be added to the Driver/Passenger Cab windows.”
Note: The WA-DOC 34 passenger PT’s currently being built have 35% VLT tint on the driver’s/passenger’s side windows, and 5%VLT tint on the crew cab windows. Confirm no tint this time?
No added tint at this time. Need to discuss. Current drivers complain of low visibility in low light.
Exhibit
C(1) 4.7.3 please clarify / confirm how many windows you'd like this vehicle to have. (there is contradictory information in this section regarding the number of windows) There should be 12 windows, 6 on each side. They should be spaced out evenly, but also in a manner to ensure 1 of these windows in positioned in Compartment 4, 8, and 7 the lavatory compartment. The only compartments without exterior windows will be #1, 2,3, and 9 the single isolation cells. There are 2 additional windows, one on the curbside door and one on the rear door of the module.
Exhibit
C(1), 4.5
“Made of bright aluminum diamond plate shall cover front module comers 24" up from bottom of the body, 2.5" down the side of body, and meet the cab at the front of body.”
For better coverage, is it acceptable to carry the front rock guards 30” up from the bottom of the module?
Acceptable
Exhibit
C(1) 4.10 please tell us your preference regarding size and location for the GAS PORT openings for the general population areas.
After confirming, we do not require gas ports.
Exhibit
C(1), 4.10
“Four (4) "gas ports" openings shall be installed, two (2) on each side of the module. Each port shall have a small box pan formed door with a locking paddle latch.”
Please confirm four gas ports?
After confirming, we do not require gas ports.
Exhibit
C(1), 5.3
“Eleven (11) Freedman Seating # CITI-36223-2Prig gray 36” W two-person prison bench seats with mounting hardware.”
Are formed aluminum bench seats coated with textured gray polyurea (truck bed liner) acceptable?
Prefer the Freedman seats. We were informed they are available. However, formed aluminum bench would be acceptable if that notice was in error.
Example drawings:
C(1), 5.4
“A Shurflo #4048 RV style bypass electric water pump with Shurflo 255 series strainer shall be installed. The pump shall be mounted in Compartment #8.”
Would it be acceptable to install the pump under the bench in Cell #8, with an exterior access door?
Acceptable
Exhibit
C(1), 5.5
“A 20-gallon fresh water tank shall be installed under the bench in Cell #8, with an access panel on the forward wall of the lavatory to provide maintenance access.
A 25-gallon black water tank shall be installed below the lavatory floor, with an exterior RV-style waste outlet connection.”
A 25 gallon waste tank will not fit in the allotted space. Would it be acceptable to update to a 15 gallon fresh water tank and 20 gallon waste tank, to match Acceptable
10-
Exhibit C(1), 6.1
“SWITCHES
1. Left Scene
2. Right Scene
3. Rear Scene
4. Flashers
5. Exhaust Vent
6. Exhaust Vent
7. Blank
8. Blank”
The WA-DOC 34 passenger PT’s currently being built have the following switch layout…ok to match, and add Baja Designs driving lightbar? Acceptable
“Dome Left Scene Right Scene Rear Scene Flasher Vent Driving Lights [requires adding a lightbar such as a Baja Designs S8 20” lightbar used on current WA-DOC large PT builds in-progress) Blank Pilot PL-SW58B Gun Release Switch (unmarked)”
C(1), 6.2
“Module interior lighting shall consist of thirteen (13) recessed lights. There shall be one (1) light in the entry, one (1) in each passenger cell and bathroom (7 total), four (4) in the aisle, and one (1) in the rear storage area.”
Would it be acceptable to add one additional light over the center aisle in the group cell, total of fourteen?
C(1), 6.3
“Two (2) LED Whelen #70BTT stop/taillights shall be installed on the rear of the module, one (1) each side midway up.
Two (2) LED Whelen #70A00TAR turn arrows shall be installed on the rear of the module, one (1) each side, directly under stop/taillights.”
Whelen has updated their part numbers to 704BTT brake/tail/turn and 704T turn. Are these PN’s acceptable?
Acceptable
Exhibit
C(1), 6.7
“A Precision Power PPI S200.2 2-Channel amplifier shall be DOC provided for the speakers.”
Note: The Precision Power PPI S200.2 2 channel amplifier is no longer manufactured. Will a different make/model be provided?
Yes, TBD
21-
Exhibit H(1)
General Terms and Conditions
Technology liability insurance required of IT professionals, such as IT consultants, website developers, system designers, software developers, etc., is designed to protect them from claims of negligence, errors, or omissions in the services or products they provide. As the bid is to provide physical goods (prisoner transport vehicles) rather than internet technology, there is no risk exposure to the vehicle upfitter or the State. Adding such a policy would add thousands of dollars in costs; we there request that this requirement for technology liability insurance be omitted from the bid.
In regards to other insurance policy requirements, in order to keep overall pass-thru costs down to the State, would the following insurance reductions be acceptable (proposed changes shown both yellow-highlighted and in red text below)?
Required
(YES/NO)
Type of Insurance Coverage
Minimum Policy Limits
Per Occurrence/Claim
Annual Aggregate Additional Requirements
YES
Commercial
General Liability $1,000,000 $1,000,000 The policy must include a waiver of subrogation in favor of DOC.
YES
Professional
Liability/Errors & Omissions
$1,000,000 $1,000,000 The policy must include a waiver of subrogation in favor of DOC.
YES
Industrial Insurance (Workers
Compensation)
Per state law requirements
Per state law requirements
The policy shall be written to meet the statutory requirements for the state in which the work is to be performed, including occupational disease. The policy must include a waiver of subrogation in favor of DOC.
The policy shall cover all Contractor's employees, including as may be required of an "employer" as defined in Title 51 RCW, and shall be in full compliance with Title 51 RCW.
YES Employer's Liability
· Each Accident:
$1,000,000
· Disease, Each Employee:
$1,000,000
· Disease, Policy Limit: $1,000,000
N/A
YES
Umbrella or Excess Liability
$2,000,000 $2,000,000
For Industrial Insurance, Employer's Liability, Commercial General Liability and Business Automobile Liability coverages. The policy must include a waiver of subrogation in favor of DOC.
YES
Business
Automobile Liability
$1,000,000 $2,000,000 The policy must include a waiver of subrogation in favor of DOC.
YES Cyber Liability $1,000,000 $1,000,000
Coverage shall be sufficiently broad to respond to the duties and obligations as is undertaken by Contractor in this agreement and shall include, but not be limited to, claims involving infringement of intellectual property, including but not limited to infringement of copyright, trademark, trade dress, invasion of privacy violations, information theft, damage to or destruction of electronic information, release of private information, alteration of electronic information, extortion and network security.
The policy shall provide coverage for breach response costs as well as regulatory fines and penalties as well as credit monitoring expenses with limits sufficient to respond to these obligations. The policy must include a waiver of subrogation in favor of DOC.
See attached updated insurance requirements. Coverage types have and coverage amounts for certain types of coverage have been reduced.
ATTACHMENT A(1)
REQUIRED INSURANCE COVERAGES
Washington State [Subject] Page 1 of 1 Department of Corrections 24XXX
Required
(YES/NO)
Type of Insurance Coverage
Minimum Policy Limits
Per Occurrence/Claim
Annual Aggregate
Additional Requirements
YES
Commercial
General Liability
$1,000,000 $1,000,000 The policy must include a waiver of subrogation in favor of DOC.
YES
Professional
Liability/Errors & Omissions
$1,000,000 $1,000,000 The policy must include a waiver of subrogation in favor of DOC.
YES
Industrial Insurance (Workers
Compensation)
Per state law requirements
Per state law requirements
The policy shall be written to meet the statutory requirements for the state in which the work is to be performed, including occupational disease. The policy must include a waiver of subrogation in favor of DOC. The policy shall cover all Contractor's employees, including as may be required of an "employer" as defined in Title 51 RCW, and shall be in full compliance with Title 51 RCW.
YES Employer's Liability
· Each Accident:
$1,000,000
· Disease, Each Employee:
$1,000,000
· Disease, Policy Limit: $1,000,000
N/A
YES
Umbrella or
Excess Liability $2,000,000 $2,000,000
For Industrial Insurance, Employer's Liability, Commercial General Liability and Business Automobile Liability coverages. The policy must include a waiver of subrogation in favor of DOC.
YES
Business
Automobile Liability
$1,000,000 $2,000,000 The policy must include a waiver of subrogation in favor of DOC.