Att 5 03200ConcreteReinforcement.doc

DOC document 31 KB Posted

Attached to
RECOVERY-CNF Wastewater Improvements Federal contract opportunity
Solicitation number
AG-9702-S-10-0383
Issued by
Department of Agriculture Forest Service Washington Office Economic Recovery Operations Center Southwest

About this file

Att 5 Specification - Concrete Reinforcement

View the file

Other files for this federal contract opportunity

Other files attached to RECOVERY-CNF Wastewater Improvements, newest first.
File Type Posted
A-4 SF-30.pdf PDF
ScheduleOfItems060110REV.doc DOC document
Att 2 01505Mobilization.doc DOC document
Att 4 03100ConcreteFormwork.doc DOC document
Att 1 REV SCHED amend 3.docx DOCX document
Att 3 02050Demolition.doc DOC document
A-3 SF 30 S-10-0383.pdf PDF
Att 7 - SilveradoFireStationSitePlanv2004 Layout1 —
Att 8 - SilveradoFireStationSeptic Leachv2004 Layout1 —
Att 5 - ElCarisoHotShotSeptic LeachWestREV West End —
Att 2 - 1TitleSheet USFS-Dsize(24X36) —
Att 3 - LegendAndNotesREV Site Plan —
Att 4 - ElCarisoHotShotSitePlanREV SitePlan —
A-2 SF-30.doc DOC document
Att 6 - ElCarisoHotShotSeptic LeachEastREV East End —
Att 9 - Plumbing DetailsA B Layout1 —
A-1.pdf PDF
ATT 2 - REVISED Section I M.doc DOC document
ATT 1 - REVISED SF-18.PDF PDF
Att 1_ElCarisoHotShotProjectLocationMap.pdf PDF
Att 4 San Diego County Wage Determination_CA1.pdf PDF
Att 3 Vicinity Map_Detail Drawings.PDF PDF
Att 5 Orange County Wage Determination_CA35.pdf PDF
Att 2_SilveradoProjectLocationMap.pdf PDF
Att 6 Riverside County Wage Determination_CA36.pdf PDF
S-10-0383_RFQ.doc DOC document
Show all 26

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WASTEWATER IMPROVEMENTS CNF

SECTION 03200 - CONCRETE REINFORCEMENT

PART 1 - GENERAL

1.1

SECTION INCLUDES

A. Reinforcing steel bars, wire fabric and accessories for cast-in-place concrete.

1.2

RELATED SECTIONS

A. Section 03100 - Concrete Formwork.

B. Section 03300 - Cast-in-Place Concrete.

1.3

REFERENCES

A. ACI 30 - Structural Concrete for Buildings.

B. ACI 318 - Building Code Requirements For Reinforced Concrete.

C. ACI SP-66 - American Concrete Institute – Detailing Manual.

D. ASTM A82 - Cold Drawn Steel Wire for Concrete Reinforcement.

E. ASTM A185 - Welded Steel Wire Fabric for Concrete Reinforcement.

F. ASTM A615 - Deformed and Plain Billet Steel Bars for Concrete Reinforcement.

G. AWS D 1.4 - Structural Welding Code for Reinforcing Steel.

H. CRSI - Concrete Reinforcing Steel Institute – Manual of Practice.

I. CRSI 63 – Recommended Practice For Placing Reinforcing Bars.

J. CRSI 65 – Recommended Practice For Placing Bar Supports, Specifications and

Nomenclature.

1.4

SUBMITTALS FOR REVIEW

A. Section 01300 – Submittals: Procedures for submittals.

B. Shop Drawings: Indicate bar sizes, spacing, locations, and quantities of reinforcing steel, Bending and cutting schedules, and supporting.

1.5

SUBMITTALS FOR INFORMATION

A. Section 01300 – Submittals: Procedures for submittals.

B. Manufacturer’s Certificate: Certify that products meet or exceed specified requirements.

C. Submit certified copies of mill report or reinforcement materials analysis.

1.6

QUALITY ASSURANCE

A. Perform Work in accordance with ACI 301 and ACI SP-66.

1.7

MEASUREMENT AND PAYMENT

A. No separate measurement or payment will be made for work specified in this section.

PART 2 - PRODUCTS

2.1

REINFORCEMENT

A. Reinforcing Steel: ASTM A615, 60 ksi yield grade; deformed billet steel bars.

2.2

ACCESSORIES

A. Tie Wire Minimum 16.

B. Chairs, Bolsters, Bar Supports, Spacers: Sized and shaped for strength and support of reinforcement during concrete placement conditions including load bearing pad on bottom to prevent vapor barrier puncture.

C. Special Chairs, Bolsters, Bar Supports, Spacers Adjacent to Weather Exposed Concrete

Surfaces: Stainless steel type; size and shape as required.

2.3

FABRICATION

A. Fabricate concrete reinforcing in accordance with ACI SP-66.

B. Locate reinforcing splices not indicated on drawings, at point of minimum stress. Review location of splices with Contracting Officer.

PART 3 - EXECUTION

3.1

PLACEMENT

A. Place, support and secure reinforcement against displacement. Do not deviate from required position.

B. Do not displace or damage vapor barrier.

C. Accommodate placement of formed openings.

D. Maintain concrete cover around reinforcing as follows:

Item:

Coverage:

Footings and Concrete Formed Against Earth

3 inch Slabs on Grade

3 inch

3.2

FIELD QUALITY CONTROL

A. Section 01400 - Quality Control: Field inspection.

B. Inspect for acceptability.

END OF SECTION 03200