Acton - Drawing Cover T1.pdf

PDF 807 KB Posted

Attached to
Acton District Office Construction Federal contract opportunity
Solicitation number
AG-91S8-S-10-0014
Issued by
Department of Agriculture Forest Service R5-Pacific Southwest Region

About this file

Drawing Cover T1

View the file

Other files for this federal contract opportunity

Other files attached to Acton District Office Construction, newest first.
File Type Posted
Section 09513.pdf PDF
Section_09650.pdf PDF
SF 30 Acton Amendment No. 4 pdf.pdf PDF
Summary of Changes.pdf PDF
SECTION M.pdf PDF
Section L.pdf PDF
Summary of Amendment 03.pdf PDF
Boring Logs.pdf PDF
SF 30 Acton Amendment No. 3.pdf PDF
AGAR 452.288-71 Insurance.pdf PDF
Attendee Sign-In Sheet.pdf PDF
Acton Notes and Q As_503.pdf PDF
Attendee Business Cards.pdf PDF
SF 30 Acton Amendment No. 2.pdf PDF
Acton Amendment No. 1.pdf PDF
Continuation.docx DOCX document
281300.pdf PDF
Acton - Landscape Drawings.pdf PDF
Acton - Architectural Drawings.pdf PDF
Acton Geotechnical1.pdf PDF
Acton Fire Station 100 Specs.pdf PDF
1-21-10 Acton Fire Station 100 Drawings.pdf PDF
Acton - Electrical Drawings.pdf PDF
Acton District office-0318.docx DOCX document
Acton - Structural Drawings.pdf PDF
Acton Final Specification Binder.pdf PDF
Acton - Bridge Drawings.pdf PDF
Acton - Plumbing Drawings.pdf PDF
Acton - Mechanical Drawings.pdf PDF
Acton - Civil Drawings.pdf PDF
Show all 30

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OCCUPANT LOAD & EGRESS REQUIREMENT:

Area / Load Factor

Occup Load

Subtotal Occup Load

Exit Access

OFFICE BUILDING

Lobby 320 SF 15 21.3 * 25.4 1 Reception 107 SF 100 1.1 LE Offices 300 SF 100 3.0 Conference Room 615 SF 15 41.0 41.0 1 Group Offices 1845 SF 100 18.5 28.4 1 Private Offices 993 SF 100 9.9 Lunch 158 SF 15 10.5 * 10.5 1 Storage/Equipment 582 SF 300 1.9 * 1.9 1 Restrooms/Janitor 525 SF - 0.0 Circulations 1317 SF - 0.0 Walls/Cavities 842 - 0.0 Total Office Building 7604 SF 73 2

WAREHOUSE

Office 260 SF 100 2.6 3.4 1 Locker 34 SF 50 0.7 * Data 38 SF 300 0.1 * Wellness 720 SF 50 14.4 14.4 1 Wareshouse 1623 500 3.2 6.0 1 Storage 813 300 2.7 * Restrooms 403 SF - 0.0 Circulations 178 SF - 0.0 Walls/Cavities 299 SF - 0.0 Total Warehouse 4368 SF 20 1

GROSS TOTAL 11972 SF

* Accessory Use not included in computing total occupant load.

MINIMUM NUMBER OF PLUMBING FIXTURES: [CPC Table 4-1]

Office or Public Buildings - for employee use Total occupant load: 35 (18 male & 18 female)

WC's Urinals Lavs Showers DF's Male 2 1 1 0 0

Female 3 0 1 0

Office or Public Buildings Total occupant load: 73 (37 male & 37 female)

WC's Urinals Lavs Showers DF's Male 1 1 1 0 1

Female 3 0 1 0

Industrial Warehouses - for employee use Total occupant load: 20 (10 male & 10 female)

WC's Urinals Lavs Showers DF's Male 1 0 1 1 1

Female 1 0 1 1