OCCUPANT LOAD & EGRESS REQUIREMENT:
Area / Load Factor
Occup Load
Subtotal Occup Load
Exit Access
OFFICE BUILDING
Lobby 320 SF 15 21.3 * 25.4 1 Reception 107 SF 100 1.1 LE Offices 300 SF 100 3.0 Conference Room 615 SF 15 41.0 41.0 1 Group Offices 1845 SF 100 18.5 28.4 1 Private Offices 993 SF 100 9.9 Lunch 158 SF 15 10.5 * 10.5 1 Storage/Equipment 582 SF 300 1.9 * 1.9 1 Restrooms/Janitor 525 SF - 0.0 Circulations 1317 SF - 0.0 Walls/Cavities 842 - 0.0 Total Office Building 7604 SF 73 2
WAREHOUSE
Office 260 SF 100 2.6 3.4 1 Locker 34 SF 50 0.7 * Data 38 SF 300 0.1 * Wellness 720 SF 50 14.4 14.4 1 Wareshouse 1623 500 3.2 6.0 1 Storage 813 300 2.7 * Restrooms 403 SF - 0.0 Circulations 178 SF - 0.0 Walls/Cavities 299 SF - 0.0 Total Warehouse 4368 SF 20 1
GROSS TOTAL 11972 SF
* Accessory Use not included in computing total occupant load.
MINIMUM NUMBER OF PLUMBING FIXTURES: [CPC Table 4-1]
Office or Public Buildings - for employee use Total occupant load: 35 (18 male & 18 female)
WC's Urinals Lavs Showers DF's Male 2 1 1 0 0
Female 3 0 1 0
Office or Public Buildings Total occupant load: 73 (37 male & 37 female)
WC's Urinals Lavs Showers DF's Male 1 1 1 0 1
Female 3 0 1 0
Industrial Warehouses - for employee use Total occupant load: 20 (10 male & 10 female)
WC's Urinals Lavs Showers DF's Male 1 0 1 1 1
Female 1 0 1 1