Addendum 2_Attachment 2.pdf

PDF 19 MB Posted

Attached to
Intrusion and Fire Alarms
Solicitation number
13060-0-2025-BP
Issued by
Dane County, Mattoon Village, Wisconsin

About this file

I apologize, but I don't see the actual contents of "Addendum 2_Attachment 2.pdf" in the provided text. While I can see that this file is related to an Intrusion and Fire Alarms contract opportunity in Wisconsin, I cannot provide a summary of its contents without access to the actual document. To provide an accurate summary, I would need to see the contents or text within the addendum attachment.

View the file

Other files

File Type Posted
Addendum 2_Attachment 5.pdf PDF
Addendum 2_Attachmen 1.pdf PDF
13060 Addendum 1.pdf PDF
13060 Addendum 2.pdf PDF
13060-0-2025-BP Intrustion and Fire Alarms.pdf PDF
13060 Summary.pdf PDF
Addendum 2_Attachment 3.pdf PDF
13060-Form D2.xlsx XLSX spreadsheet
13060-Appendix C.xlsx XLSX spreadsheet
Addendum 2_Attachment 4.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5525 Nobel Drive, Suite 110 | Madison, WI 53711 | 608.277.1728 | www.jdrengineering.com

SHOP DRAWING REVIEW

This review is limited to checking for general conformance with the design concept, and for general compliance with information given in the Construction Documents. Corrections or comments made on these shop drawings do not relieve the contractor from the obligation to comply with the requirements of the drawings and specifications. Approval of a specific item shall not constitute approval of an assembly in which the item is a component. Contractor is responsible for: confirming and correlating all dimensions and quantities; information that pertains solely to the fabrication processes; the means, methods, techniques, sequences and procedures of construction; performing work in a safe and satisfactory manner; and coordinating work with that of all other trades.

Project Name: SSCG Phase 1 Date: 05/16/2024

Project No: 22.0249 Reviewed By: Joe Mullvain

Description: 28 46 21 Fire Alarm

A p p ro v e d p ro v e d a s

C o rr e ct

R

-v is e a n d

R e su b m it je ct ed

S u b m it S p e ci fi e d

I te b m it ta l N o t

R e q u e st e d

R e tu rn n o t

R e v ie w

Item No. References Comments

☒ ☐ ☐ ☐ ☐ ☐ 1 Floor Plans, Details &

Riser Diagrams

Reviewed for general compliance and project scope.

Contractor shall verify all code required aspects and submit drawings and specifications to the local AHJ for approval.

☒ ☐ ☐ ☐ ☐ ☐ 2 Controller Module No objections.

☒ ☐ ☐ ☐ ☐ ☐ 3 Control Relay No objections.

☒ ☐ ☐ ☐ ☐ ☐ 4 Aux Power Supply No objections.

☒ ☐ ☐ ☐ ☐ ☐ 5 Booster Power Supply No objections.

☒ ☐ ☐ ☐ ☐ ☐ 6 Audio Amplifier No objections.

☒ ☐ ☐ ☐ ☐ ☐ 7 Lead Acid Battery No objections.

☒ ☐ ☐ ☐ ☐ ☐ 8 Wall Mount Speaker /

Speaker Strobe No objections.

☒ ☐ ☐ ☐ ☐ ☐ 9 Ceiling Mount Speaker /

Speaker Strobe No objections.

☒ ☐ ☐ ☐ ☐ ☐ 10 Manual Pull Station No objections.

☒ ☐ ☐ ☐ ☐ ☐ 11 Heat Detector No objections.

☒ ☐ ☐ ☐ ☐ ☐ 12 Smoke Detector No objections.

☒ ☐ ☐ ☐ ☐ ☐ 13 Smoke Detector / CO

Sensor No objections.

☒ ☐ ☐ ☐ ☐ ☐ 14 Signal Module No objections.

☒ ☐ ☐ ☐ ☐ ☐ 15 Output Module No objections.

Re: Lake St Development Page #2 p ro v p ro v e d a s

C o rr e ct

-v is e a n d

R e su b it je ct ed b m it S p e ci fi e d

I te b m it ta l N o t

R e q u e st e d

R e tu rn n o t

R e v ie w

Item No. References Comments

☒ ☐ ☐ ☐ ☐ ☐ 16 Control Relay Module No objections.

☒ ☐ ☐ ☐ ☐ ☐ 17 Input Module No objections.

☒ ☐ ☐ ☐ ☐ ☐ 18

Voltage Drop, Battery Calculations, Amplifier

Calculations, & Address ID’s

Reviewed for general compliance and project scope.

Contractor shall verify all code required aspects and submit drawings and specifications to the local AHJ for approval.

☐ ☐ ☐ ☐ ☐ ☐ 19

☐ ☐ ☐ ☐ ☐ ☐ 20

9361-State St Campus Garage Mixed-Use Project-CONS #126-Fire Alarm SD & PD

Created by Joe Mullvain with Autodesk® Construction Cloud™ on May 16, 2024 at 2:08 PM CDT Page 1 of 3

Submittal item detail

#28 46 21-126-0: Fire Alarm SD & PD

Status Created on Due date

Open In Review

Mar 4, 2024 May 17, 2024

ID 229

Ball in court Joe Mullvain (JDR Engineering Inc.)

Michael Jochman (JDR Engineering Inc.)

Rachel Steffen (EUA (Eppstein Uhen Architects, Inc.))

DESIGN-A/E-PROJ MGR

Manager DESIGN-A/E-PROJ MGR

Responsible contractor CONTRACTOR-GC-PROJ MGR

Watchers PROJECT USERS

Spec section 28 46 21 Electronic Safety and Security

Spec sub section

Description Fire Alarm SD & PD

Final Response

Final Response Attachments

Final Response Comments

Package https://acc.autodesk.com/build/submittals/projects/096dc208-2e01-49e8-ae16-9afe0638c914/items?preview=de3b597c-ff13-4a65-9826-a205c40bb12f&tab=overview https://acc.autodesk.com/build/submittals/projects/096dc208-2e01-49e8-ae16-9afe0638c914/items?preview=de3b597c-ff13-4a65-9826-a205c40bb12f&tab=overview

Created by Joe Mullvain with Autodesk® Construction Cloud™ on May 16, 2024 at 2:08 PM CDT Page 2 of 3

Ball in court Sent Due Returned Response/Action Attachments

Submitted

CONTRACTOR-GC-PROJ

MGR

Submitted by Tyler Welch

Mar 4, 2024 Jul 7, 2024 May 3, 2024 Submitted 28 46 21-1 Fire Alarm SD & PD.pdf

Comments -

Sent for review

DESIGN-A/E-PROJ MGR

Sent by Todd King

May 3, 2024 Jul 21, 2024 May 10, 2024 Sent for review 28 46 21-1 Fire Alarm SD & PD.pdf

Comments -

Review Step 1

Joe Mullvain (JDR Engineering Inc.)

May 10, 2024 May 16, 2024 -

Comments

Michael Jochman (JDR Engineering Inc.)

May 10, 2024 May 16, 2024 -

Comments

DESIGN-A/E-PROJ MGR May 10, 2024 May 16, 2024 -

Comments

Rachel Steffen May 10, 2024 May 16, 2024 May 15, 2024 Reviewed w/No Comment https://developer.api.autodesk.com/reports/v2/attachments/urn%3Aadsk.wipprod%3Afs.file%3Avf.zQzIJKinQrOAxwApEaf4mQ%3Fversion%3D1?projectId=096dc208-2e01-49e8-ae16-9afe0638c914&region=US&token=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJkYXRhIjp7InVybiI6InVybjphZHNrLndpcHByb2Q6ZnMuZmlsZTp2Zi56UXpJSktpblFyT0F4d0FwRWFmNG1RP3ZlcnNpb249MSJ9LCJpYXQiOjE3MTU4ODY1MTAsImV4cCI6MTcxODQ3ODUxMH0.dpmt6DORSOHs7u72ZmM07saaQ9f5N2bOFOiMdcLmA9E https://developer.api.autodesk.com/reports/v2/attachments/urn%3Aadsk.wipprod%3Afs.file%3Avf.zQzIJKinQrOAxwApEaf4mQ%3Fversion%3D1?projectId=096dc208-2e01-49e8-ae16-9afe0638c914&region=US&token=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJkYXRhIjp7InVybiI6InVybjphZHNrLndpcHByb2Q6ZnMuZmlsZTp2Zi56UXpJSktpblFyT0F4d0FwRWFmNG1RP3ZlcnNpb249MSJ9LCJpYXQiOjE3MTU4ODY1MTAsImV4cCI6MTcxODQ3ODUxMH0.dpmt6DORSOHs7u72ZmM07saaQ9f5N2bOFOiMdcLmA9E

Created by Joe Mullvain with Autodesk® Construction Cloud™ on May 16, 2024 at 2:08 PM CDT Page 3 of 3

Ball in court Sent Due Returned Response/Action Attachments

(EUA (Eppstein Uhen Architects, Inc.)) Reviewed By Rachel Steffen

Comments

Review Step 2

COM-ENG-CB/RFI/SUBM

MGR

Comments

SUBMITTAL

TRANSMITTAL

P.O Box 7726 Madison WI 53707 Phone: 608.222.5100

Project: 23-2008-0 State Street Campus Garage

Date Submitted: Response Due:

To: Stevens Construction Corp.

Title:

Type:

Spec:

Requested By:

We are sending:

SUBMITTAL PACKAGE

FOR

STATE STREET CAMPUS GARAGE

FIRE ALARM – SHOP DRAWINGS

SPEC SECTION 28 46 21

Prepared by Electrical Contractor:

NEXT Electric, LLC Arden Parfitt, Senior Project Manager

4009 Felland Rd., Suite 106 Madison, WI 53718

Arden.Parfitt@nextelectricllc.com Ph: (608) 371-1158 Fax: (262) 506-3201 www.nextelectricllc.com mailto:Arden.Parfitt@nextelectricllc.com http://www.nextelectricllc.com/

900 Oregon Center Dr. Oregon, WI 53575 │ O: 608.819.1980 F:608.819.1981 │ www.omnitechnologiesllc.com

NURSE CALL │ FIRE ALARM │ AUDIO/VIDEO │ SECURITY

SUBMITTAL TRANSMITTAL

Sent Via:

Emailed Drop Box

To: Next Electric From: Tom Sweet

Arden Parfitt Project Manager 608-819-6657

Email: arden.parfitt@nextelectricllc.com tsweet@omnitechnologiesllc.com

Project Coordinator kdulaney@omnitechnologiesllc.com

Project: State Street Campus Garage Job# 23-2176-1

Description: 283100 Fire Alarm – Shop Drawing

Original Date: 4/18/24 Revision Date:

Submittal# 1 Revision # mailto:arden.parfitt@nextelectricllc.com mailto:tsweet@omnitechnologiesllc.com mailto:kdulaney@omnitechnologiesllc.com

FIRE

ALARM

TITLE

PAGE

FA000

DATE:

O re go n

C en te r D r.

O re go n, W

I 5

Te l:

8.

9.

Fa x:

.8

.1 w w w .o m ni te ch no lo gi es llc .c om

ST

AT

E

ST

R

EE

T C

AM

PU

S G

AR

AG

E

N

O

RT

H

LA

KE

S

TR

EE

T M

AD

IS

O N

, W I 5

REVISIONS

DWG BY:

4-1-24 23-2176

AG

FI

RE

A

LA

RM

P

LA

N

JOB #

WIRING SELECTION & GUIDELINES

PLENUM CABLE VS. NON-PLENUM

THE NEC RECOGNIZES 3 TYPES OF POWER LIMITED FIRE ALARM CABLING:

FPL - THIS IS A GENERAL USE POWER LIMITED FIRE ALARM CABLING. IT

CANNOT BE USED IN A PLENUM SPACE OR FOR RISERS (CABLING

BETWEEN FLOORS).

FPLR - THIS IS A POWER LIMITED RISER RATED CABLE THAT CAN BE USED

FOR GENERAL PURPOSES OR BETWEEN FLOORS. IT CANNOT BE USED

IN A PLENUM SPACE.

FPLP - THIS IS A POWER LIMITED CABLE THAT CAN BE USED IN A PLENUM,

RISER, OR FOR GENERAL PURPOSES.

A PLENUM IS AN AREA USED TO CONDUCT ENVIRONMENTAL AIR. PLENUM

SPACES CAN BE DUCTWORK, THE SPACE ABOVE A DROP CEILING, OR

BELOW A RAISED FLOOR. BECAUSE THESE SPACES ARE BEING USED FOR

THE AIR HANDLING SYSTEM THERE ARE STRICT RULES THAT MUST BE

FOLLOWED TO REDUCE THE RISK OF INTRODUCING TOXIC FUMES IN THE

EVENT OF A FIRE. SINCE FIRE ALARM CABLING IS OFTEN INSTALLED

EXPOSED, WITHOUT, CONDUIT, ABOVE DROP CEILINGS THE CABLING

MUST BE RATED FOR USE IN A PLENUM SPACE.

CIRCUIT MARKING NEC (NFPA 70) ARTICLE 760.42

THE EQUIPMENT SHALL BE DURABLY MARKED WHERE PLAINLY VISIBLE TO

INDICATE EACH CIRCUIT THAT IS POWER-LIMITED FIRE ALARM CIRCUIT.

EXCEPTION WHERE A POWER-LIMITED CIRCUIT IS TO BE RECLASSIFIED AS

A NON-POWER-LIMITED CIRCUIT.

SUPPORT OF CONDUCTORS PER NEC (NFPA 70) ARTICLE 760.57

POWER-LIMITED FIRE ALARM CIRCUIT CONDUCTORS SHALL NOT BE

STRAPPED, TAPED, OR ATTACHED BY ANY MEANS TO THE EXTERIOR OF

ANY CONDUIT OR OTHER RACEWAY AS A MEANS OF SUPPORT.

WIRE ROUTING

NEC (NFPA 70) ARTICLE 760.5 SEPARATION FROM ELECTRIC LIGHT POWER,

CLASS 1, NPLFA, AND MEDIUM POWER NETWORK-POWERED BROADBAND

COMMUNICATIONS CIRCUIT CONDUCTORS.

(A) GENERAL POWER-LIMITED FIRE ALARM CIRCUIT CABLES AND

CONDUCTORS SHALL NOT BE PLACED IN ANY CABLE, CABLE TRAY,

COMPARTMENT, ENCLOSURE, MANHOLE, OUTLET BOX, DEVICE BOX,

RACEWAY, OR SIMILAR FITTING WITH CONDUCTORS OF ELECTRIC LIGHT,

POWER, CLASS 1, BROADBAND COMMUNICATIONS CIRCUITS UNLESS

PERMITTED BY 760.55

IN HOISTWAYS POWER-LIMITED FIRE ALARM CIRCUIT CONDUCTORS SHALL

BE INSTALLED IN RIGID METAL CONDUIT, RIGID NONMETALLIC CONDUIT,

INTERMEDIATE METAL CONDUIT, LIQUID TIGHT FLEXIBLE NONMETALLIC

CONDUIT OR ELECTRICAL METALLIC TUBING FOR ELEVATORS OR SIMILAR

EQUIPMENT. THESE CONDUCTORS SHALL BE PERMITTED TO BE

INSTALLED AS PROVIDED IN 620.21

NEC (NFPA 70) ARTICLE 760.61 APPLICATION OF LISTED PLFA CABLES,

PLFA CABLES SHALL COMPLY WITH THE REQUIREMENTS DESCRIBED IN

EITHER 760.61 (A), (B) OR (C) OR WHERE CABLE SUBSTITUTIONS ARE MADE

AS SHOWN IN 760.61 (D).

CABLES INSTALLED IN DUCTS, PLENUMS, AND OTHER SPACES USED FOR

ENVIRONMENTAL AIR SHALL BE TYPE FPLP. ABANDONED CABLES SHALL

NOT BE PERMITTED TO REMAIN. TYPES FPLP, FPLR, AND FPL CABLES

INSTALLED IN COMPLIANCE WITH 300.22 SHALL BE PERMITTED.

CABLES INSTALLED IN VERTICAL RUNS AND PENETRATING MORE THAN

ONE FLOOR, OR CABLES INSTALLED IN VERTICAL RUNS IN A SHAFT, SHALL

BE TYPE FPLR. FLOOR PENETRATIONS REQUIRING TYPE FPLR SHALL

CONTAIN ONLY CABLES SUITABLE FOR RISER OR PLENUM USE.

ABANDONED CABLES SHALL NOT BE PERMITTED TO REMAIN.

SHIELDED CABLE

IF SHIELDED CABLE IS USED, THE SHIELDS SHALL BE SPLICED THROUGH

AT EACH JUNCTION. SHIELDS SHALL BE SEPARATED FROM ALL OTHER

CONDUCTORS, AND TAPED WHEN SPLICED THROUGH TO PREVENT

GROUNDING OF THE SHIELD IN THE FIELD. THE SHIELD SHALL BE LEFT

FLOATING AT THE LAST DEVICE. ALL SHIELDS WILL BE GROUNDED AT THE

CONTROL PANEL(S), AND ONLY AT THE CONTROL PANEL(S).

PARTIAL EVACUATION & CABLE SURVIVABILITY

IF RELOCATION OR PARTIAL EVACUATION OF BUILDING OCCUPANTS IS TO

BE USED UPON ACTIVATION OF A FIRE ALARM, CABLE SURVIVABILITY

REQUIREMENTS MUST BE FOLLOWED. WHERE NOTIFICATION ZONES ARE

SEPARATED BY LESS THE TWO-HOUR FIRE-RATED CONSTRUCTION,

A PATHWAY SURVIVABILITY OF LEVEL 1, 2 OR 3 SHALL BE PERMITTED.

CABLE TO BE INSTALLED PER THE REQUIREMENTS OF NFPA 72

CHAPTER 24.

REVIEWED BY:

MIKE RESS

CHECK LIST FOR START UP

THE FOLLOWING IS A LIST OF CRITERIA THAT MUST BE MET PRIOR TO START UP

- MARK UP THE OMNI TECHNOLOGIES, LLC. DRAWINGS SHOWING

- THE ACTUAL WIRE RUNS AND ANY DISCREPENCIES/CHANGES

BETWEEN THE ACTUAL CONDITIONS, LOCATIONS, WIRE RUNS

AND THE SYSTEM DRAWINGS SHOULD BE NOTATED FOR

INCLUSION ON THE FINAL AS-BUILT DRAWING OF RECORD.

- ALL DEVICES HAVE BEEN INSTALLED AND TERMINATED

PROPERLY

- CONTACT OMNI TECHNOLOGIES, LLC. PROJECT MANAGER

FIFTEEN BUSINESS DAYS PRIOR TO SCHEDULED START-UP

- IF YOUR SYSTEM IS BEING FURNISHED WITH A DIALER, (2) RJ31X

PHONE JACKS MUST BE INSTALLED WITHIN 3 FT. OF THE FACP.

THESE PHONE LINES MUST BE CONNECTED BEFORE ALL

BUILDING PHONE EQUIPMENT, (NO "9" PREFIX), AND SHOULD

HAVE NO DIAL-OUT RESTRICTIONS. PROVIDE THE OMNI

TECHNOLOGIES, LLC. PROJECT MANAGER WITH A CUSTOMER

EMERGENCY CALL. LIST. IF THE MONITORING IS NOT PROVIDED

BY OMNI TECHNOLOGIES, LLC. THEN FOLLOWING INFORMATION

MUST ALSO BE OBTAINED PRIOR TO START UP: CENTRAL

STATION ACCOUNT NUMBER, RECEIVER PHONE NUMBERS,

CENTRAL STATION VOICE LINE NUMBER, AND ALARM COMPANY

PHONE NUMBER.

- ALL FIELD DEVICES, SMOKE DETECTORS, MONITOR MODULES,

CONTROL MODULES NOTIFICATION APPLIANCES BOTH VISUAL

AND AUDIBLE ARE ADDRESSED AND OUTPUT SET (AS REQUIRED)

AND INSTALLED.

CHECK FIELD WIRING WITH AN OHM METER:

- MEASURE EACH CONDUCTOR OF THE ADDRESSABLE LOOP (SLC)

TO GROUND, CONDUCTOR TO CONDUCTOR, CONDUCTOR TO

SHIELD, AND SHIELD TO EARTH. THE RESISTANCE SHOULD BE

GREATER THAN 1 MEGA OHM. NOTE LINE TO LINE

MEASUREMENTS REQUIRE ONE END OF THE PAIR TO BE

SHORTED. STRAY VOLTAGE SHOULD BE LESS THAN 1 VDC/AC.

RECORD THE READINGS

- MEASURE EACH CONDUCTOR OF THE NOTIFICATION APPLIANCE

CIRCUIT (NAC) TO GROUND, AND CONDUCTOR TO CONDUCTOR.

THE RESISTANCE SHOULD BE GREATER THAN 1 MEGA OHM,

WITHOUT THE END OF LINE RESISTOR, STRAY VOLTAGES

SHOULD BE LESS THAN 1 VDC/AC

- MEASURE ACROSS THE CONDUCTORS OF A NOTIFICATION

APPLIANCE CIRCUIT (NAC), YOUR READING SHOULD BE

EQUIVALENT TO THE VALUE OF THE END OF THE LINE RESISTOR

INSTALLED AT THE LAST DEVICE. IF THE MEASUREMENTS ARE

NOT WITHIN THE ACCEPTABLE VALUES, THE CIRCUIT WIRING HAS

A SHORT OR AN OPEN, IT IS NOT READY FOR START UP.

BEFORE YOU START INSTALLING

1. CALL OMNI TECHNOLOGIES, LLC. (608) 819-1980 TO SCHEDULE A

PROJECT REVIEW MEETING BEFORE INSTALLING ANY DEVICES.

2. IT IS BEST TO USE "DEEP" BACK BOXES WHEN INSTALLING MODULES

AND PULL STATIONS. THE DEEP BACK BOXES WILL PROVIDE MORE

ROOM FOR THE WIRES, AND IT WILL CUT DOWN ON GROUNDS AND

SHORTS.

3. WHEN INSTALLING DEVICES, TAPE THE "IN" SIDE OF THE WIRE WITH

BLACK ELECTRICAL TAPE TO AVOID CROSSING WIRE AND POLARITY.

4. WHEN USING SHIELDED CABLE, THE SHIELD MUST BE GROUNDED

ONLY AT THE FIRE ALARM CONTROL PANEL (DO NO GROUND

ANYWHERE ELSE). SHIELDS SHALL BE KEPT CONTINUOUS

THROUGHOUT THE CIRCUIT AND KEPT FREE FROM ANY REFERENCE

TO EARTH GROUND. SHIELDS MUST BE SPLICED THRU AND

INSULATED FROM EVERY BACK BOX. DO NO LAND SHIELD ON THE

DEVICE.

5. THE CUSTOM DEVICE MESSAGES FOR ANNUNCIATION ARE BASED ON

DRAWINGS PROVIDED BY ARCHITECT/ENGINEER. IF MESSAGES ARE

GOING TO CHANGE, END USER MUST SIGN OFF.

6. ALWAYS USE GROMMETS/BUSHINGS ON THE END OF CONDUIT

STUB-UPS, IN ELECTRICAL BOXES & CONNECTION TO PANELS, & ALL

POINTS WHERE WIRING EXITS CONDUIT, TO AVOID SCRAPING OF WIRE

COATING AND POTENTIAL GROUND FAULTS.

7. REVIEW CUT SHEETS FOR ALL DEVICES TO VERIFY CORRECT

INSTALLATION PROCEDURES ARE USED. EACH EXIT DEVICE HAS

INSTALLATION AND WIRING INSTRUCTIONS INCLUDED IN PACKAGING.

ALWAYS SAVE INSTRUCTION SHEETS, CUT SHEETS AND MANUALS

FOR THE OWNER.

8. FIRE WALL AND FLOOR PENETRATIONS MUST BE PATCHED WITH

APPROVED FIRE PATCH WHICH MAINTAINS THE PARTITIONS RATING.

BOTH SIDES OF THE PENETRATION MUST BE FIRESTOPPED.

9. PRIOR TO SCHEDULING START UP WITH OMNI TECHNOLOGIES, LLC.,

VERIFY THAT YOU PROJECT MEETS ALL THE CRITERIA OUTLINED IN

THE "CHECK LIST FOR START UP". A MINIMUM OF FIFTEEN BUSINESS

DAYS IS REQUIRED FOR SCHEDULING YOU START-UP.

POWER UP/DOWN SEQUENCE

CAUTION: ALWAYS REMOVE POWER (BATTERY/AC) AND WAIT AT LEAST 10

SECONDS TO ALLOW SUPPLY VOLTAGES TO DECAY BEFORE INSTALLING

OR REMOVING ANY MODULES, DETECTOR, OR WIRING. AUXILLARY

SUPPLIES MUST BE POWERED DOWN PRIOR TO THE MAIN SUPPLIES.

1. POWER UP SEQUENCE:

A. CONNECT AC POWER FIRST.

B. CONNECT THE BATTERY SECOND

1. POWER DOWN SEQUENCE:

A. DISCONNECT THE BATTERY FIRST

B. DISCONNECT AC POWER SECOND

NOTE: PLEASE REFER TO THE LOCAL JURISDICTION (AHJ) AND A

CURRENT COPY OF THE NATIONAL FIRE PROTECTION ASSOCIATION'S

NATIONAL ELECTRICAL CODE AND NATIONAL FIRE ALARM CODE FOR ANY

QUESTIONS YOU HAVE RELATED TO CODE COMPLIANCE. ALL

INFORMATION CONTAINED ON THIS SHEET IS GENERAL INFORMATION AND

SHOULD NOT BE USED AS A SOLE SOURCE FOR INSTALLATIONS. OMNI

TECHNOLOGIES, LLC. OR THEIR EMPLOYEES SHALL NOT BE RESPONSIBLE

FOR ANY MISINTERPRETATIONS OR LIABILITIES THAT MAY ARISE FROM

THE USE OF THIS DOCUMENT.

TRK

DEVICE SETTINGS:

· SEE FLOOR PLANS FOR DEVICE CANDELA SETTING

· SEE FLOOR PLANS FOR DEVICE SPEAKER TAP SETTING

· ALL SPEAKERS TO BE SET TO 70 VRMS OPERATING VOLTAGE

DRAWING INDEX:

FA000 FIRE ALARM TITLE PAGE

FA100A LOWER FLOOR AREA A FIRE ALARM PLAN

FA100B LOWER FLOOR AREA B FIRE ALARM PLAN

FA101A FIRST FLOOR AREA A FIRE ALARM PLAN

FA101B FIRST FLOOR AREA B FIRE ALARM PLAN

FA102A SECOND FLOOR AREA A FIRE ALARM PLAN

FA102B SECOND FLOOR AREA B FIRE ALARM PLAN

FA103A THIRD FLOOR AREA A FIRE ALARM PLAN

FA103B THIRD FLOOR AREA B FIRE ALARM PLAN

FA104A FOURTH FLOOR AREA A FIRE ALARM PLAN

FA104B FOURTH FLOOR AREA B FIRE ALARM PLAN

FA105A FIFTH FLOOR AREA A FIRE ALARM PLAN

FA105B FIFTH FLOOR AREA B FIRE ALARM PLAN

FA106A SIXTH FLOOR AREA A FIRE ALARM PLAN

FA106B SIXTH FLOOR AREA B FIRE ALARM PLAN

FA200 FIRE ALARM DETAILS PAGE 1 OF 2

FA201 FIRE ALARM DETAILS PAGE 2 OF 2

FA300 FIRE ALARM RISER DIAGRAM PAGE 1 OF 2

FA301 FIRE ALARM RISER DIAGRAM PAGE 2 OF 2

GENERAL NOTES:

· E.C. TO MOUNT ALL CEILING MOUNTED STROBES BELOW 30 FEET AFF.

100°

32°

INSTALLATION GUIDELINES

THE UL LISTED OPERATING TEMPERATURE RANGE FOR

ALL ADDRESSABLE DEVICES: MOST DEVICES ARE

RATED FOR 32°F (0°C) TO 100°F (38°C). IF A DEVICE IS

SHOWN IN AN AREA WHICH MAY EXPERIENCE EXTREME

COLD OR HEAT, CONTACT YOUR OMNI TECHNOLOGIES,

LLC. REPRESENTATIVE.

GENERAL RULE: IF IT IS UNCOMFORTABLE FOR YOU,

THE DEVICE WILL PROBABLY NOT OPERATE

CORRECTLY.

NEVER ALLOW ANY FIRE ALARM EQUIPMENT TO GET

WET. ONLY WEATHERPROOF NOTIFICATION

APPLIANCES (HORN/STROBES, STROBES, ETC.) MAY BE

INSTALLED OUTSIDE.

IF EQUIPMENT DOES GET WET, CONTACT YOUR OMNI

TECHNOLOGIES, LLC. PROJECT MANAGER.

DO NOT INSTALL ADDRESSABLE DEVICES UNTIL THEY

HAVE BEEN ADDRESSED.

DO NOT INSTALL NOTIFICATION DEVICES UNTIL THE

CANDELA AND DBA SWITCHES ARE SET.

SEE THE FIRE ALARM PLAN LAYOUT FOR ADDRESSES

AND SETTINGS.

DO NOT REMOVE THE ORANGE DUST COVERS FROM

SMOKE DETECTORS UNTIL ALL CONSTRUCTION HAS

BEEN COMPLETED.

DETECTORS THAT HAVE HAD THEIR DUST COVERS

REMOVED PRIOR TO THE FINAL CLEAN-UP OF ALL

TRADES SHALL BE CLEANED OR REPLACED,

ACCORDANCE WITH NFPA 72.

OMNI TECHNOLGIES, LLC CANNOT BE RESPONSIBLE

FOR PROBLEMS FOUND TO BE DUST AND DIRT

RELATED.

ALL INITIATING DEVICES (SMOKES, MANUAL PULLS,

HEATS, MODULES, ETC.),AND NOTIFICATION

APPLIANCES (HORNS, STROBES, ETC.) MUST BE

INSTALLED WITH BACKBOXES. THE EQUIPMENT SHOULD

NEVER BE SUPPORTED WITH THE CIRCUIT WIRES.

WALL MOUNTED NOTIFICATION DEVICES TO BE

MOUNTED AT 84" AFF TO BOTTOM. IF CEILING HEIGHT IS

TOO LOW TO ACCOMPLISH THIS, DEVICE MUST BE

MOUNTED WITHIN 6" OF CEILING.

PHOTOELECTRIC SMOKE DETECTORS ARE TO BE

MOUNTED AT LEAST 3'0" FROM ANY FLUORESCENT

LIGHT OR AIR DIFFUSER.

ELEVATOR HEATS FOR SHUNT TRIP TO BE MOUNTED

WITHIN 24" OF SPRINKLER HEAD.

IF DETECTORS ARE REQUIRED IN ELEVATOR PIT.

SMOKE DETECTORS FOR ELEVATOR RECALL SHALL BE

LOCATED WITHIN 21 FEET OF THE CENTERLINE OF EACH

ELEVATOR DOOR WITHIN THE ELEVATOR BANK UNDER

THE CONTROL OF THE DETECTOR.

SMOKE DETECTORS REQUIRED FOR DOOR RELEASE

SHALL BE LOCATED WITHIN 5 FEET OF THE DOOR BEING

CONTROLLED BY THE ASSOCIATED CONTROL RELAY

SMOKE DETECTORS THAT ARE LOCATED ON SLOPED

CEILINGS SHALL BE INSTALLED BETWEEN 4” AND 36” OF

THE PEAK.

WHERE REQUIRED, PULL STATIONS SHALL BE LOCATED

WITHIN 5 FEET OF AN INDIVIDUAL EXIT DOOR.

REMOTE TEST SWITCH TO BE MOUNTED IN A VISIBLE

AND ACCESSIBLE LOCATION

WALL MOUNTED STROBES SHALL BE INSTALLED IN A

MANNER WHICH AVOIDS OBSTRUCTION BY DOORS,

CABINETS, SHELVES ETC.

DO NOT USE DUCT SMOKE ON-BOARD RELAYS FOR AHU

SHUTDOWN UNLESS SPECIFICALLY INSTRUCTED TO DO

SO ON PROJECT DRAWINGS. IT IS PREFERRED TO USE A

SEPARATE RELAY FOR INTERFACING WITH HVAC

EQUIPMENT.

SMOKE AND HEAT DETECTORS SHALL BE INSTALLED

WITHIN 12 INCHES OR LESS OF THE HIGHEST PART OF

H

S S

S

H S

DS

WP

DEVICES THAT ARE INSTALLED IN AREAS WHERE

TEMPERATURE CAN DIFFER FROM THE AMBIENT ROOM

TEMPERATURE OF THE BUILDING SHALL HAVE

CONNECTING RACEWAYS PROPERLY SEALED TO PREVENT

CONDENSATION BUILD-UP.

CEILING.

COORDINATE WITH ELEVATOR CONTRACTOR TO VERIFY

WIRE LEGEND

FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)

FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)

(NAC POWER)

FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)

(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)

FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)

FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)

FF CAT6 (DATA/PHONE)

FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)

ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND

PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE

PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.

S

SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO BOTTOM

(EDWARDS: G4SVWF WITH GRSW-10)

S

HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-HRD WITH SIGA-SB4)

S

H

CONTROL RELAY - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CR)CR

SINGLE MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT1)CT1

DUAL MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT2)CT2

CONTROL MODULE WITH SYNC - DOUBLE GANG 21

2" DEEP (EDWARDS : SIGA-CC1S)CC1S

FLOW SWITCH - BY OTHERSFS

TAMPER SWITCH - BY OTHERSTS

*AREA OF WORK = 214,027 SQ. FEET

*OCCUPANCY TYPE - S-2

APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)

BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)

ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT

(FUNCTIONAL DEVICES : RIBU1C)RIB

50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50

FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP

(EDWARDS : EST4)FACP

DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL

SYMBOL LEGEND:

SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-OSD WITH SIGA-SB4)

SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO

BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)

DENOTES ELEVATOR RECALLER

RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX

PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP

DENOTES WEATHERPROOF DEVICEWP

B

B.3

C

D

E

F

STAIR 01

0S01

STAIR 04

0S04

STAIR 02

0S02

ELEVATOR 01

0E01

ELEVATOR

LOBBY

ELEVATOR

LOBBY

ELEVATOR 04

0E04 ELEVATOR 02

0E02

ELEVATOR

LOBBY

CITY STORAGE

LOWER LEVEL

PARKING

SA1

2W 110CD

V28

WP

SA1

2W 110CD

V28

WP

SA1

2W 110CD

V8

WP

SA1

2W 110CD

V8

WP

SA1

2W 110CD

V8-EOL

WP

SA1

2W 110CD

V28

WP

SA1

2W 110CD

V8

WP

SA1

2W 110CD

V8

WP

SA1

1W 15CD

V28-EOL

1W 75CD

SA1

2W 110CD

V28

WP

1-2-23S

ER

SA1

1W 15cd

V28

1-2-155 1-2-156

1-2-7S

1-2-3S

1-2-153 1-2-154

SA1

1W 15cd

V8

MATCHLINE MATCHLINE

S 1W A1A

CT2

FS

TS

CT2

FS

TS

(1)FB TO BPS#1

A

B

DATE:

O re go n

C en te r D r.

O re go n, W

I 5

Te l:

8.

9.

Fa x:

.8

.1 w w w .o m ni te ch no lo gi es llc .c om

ST

AT

E

ST

R

EE

T C

AM

PU

S G

AR

AG

E

N

O

RT

H

LA

KE

S

TR

EE

T M

AD

IS

O N

, W I 5

REVISIONS

DWG BY:

4-1-24 23-2176

AG

FI

RE

A

LA

RM

P

LA

N

JOB #

LOWER FLOOR AREA A FLOOR FIRE ALARM PLAN

1/8" = 1'-0"

OVERALL KEY PLAN

N.T.S.

LOWER

FLOOR

AREA A

FIRE

ALARM

PLAN

FA100A

WIRE LEGEND

FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)

FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)

(NAC POWER)

FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)

(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)

FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)

FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)

FF CAT6 (DATA/PHONE)

FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)

ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND

PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE

PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.

S

SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO BOTTOM

(EDWARDS: G4SVWF WITH GRSW-10)

S

HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-HRD WITH SIGA-SB4)

S

H

CONTROL RELAY - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CR)CR

SINGLE MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT1)CT1

DUAL MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT2)CT2

CONTROL MODULE WITH SYNC - DOUBLE GANG 21

2" DEEP (EDWARDS : SIGA-CC1S)CC1S

FLOW SWITCH - BY OTHERSFS

TAMPER SWITCH - BY OTHERSTS

*AREA OF WORK = 214,027 SQ. FEET

*OCCUPANCY TYPE - S-2

APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)

BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)

ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT

(FUNCTIONAL DEVICES : RIBU1C)RIB

50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50

FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP

(EDWARDS : EST4)FACP

DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL

SYMBOL LEGEND:

SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-OSD WITH SIGA-SB4)

SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO

BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)

DENOTES ELEVATOR RECALLER

RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX

PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP

1 2 2.6 2.93 4 5 6 7 8

F

G

H

I

J

K

ELEC. VAULT

ELEVATOR 03

0E03

STAIR 03

0S03

CITY STORAGE

ELEVATOR

LOBBY

LOWER LEVEL

PARKING

S 1W A1B

SA1

2W 110CD

V7

WP

SA1

2W 110CD

V7

WP

SA1

2W 110CD

V7

WP

SA1

2W 110CD

V7

WP

SA1

1W 30CD

V7

SA1

1W 30CD

V7

SA1

2W 110CD

V8

WP

SA1

1W 75CD

V28

SA1

2W 110CD

V7-EOL

WP

SA1

2W 110CD

V28

WP

1-2-22S

1-2-21 S SA1

1W 15CD

V7

ER

(1)FB TO BPS#1

(1)FB TO BPS#1

MATCHLINE

A

B

DATE:

O re go n

C en te r D r.

O re go n, W

I 5

Te l:

8.

9.

Fa x:

.8

.1 w w w .o m ni te ch no lo gi es llc .c om

ST

AT

E

ST

R

EE

T C

AM

PU

S G

AR

AG

E

N

O

RT

H

LA

KE

S

TR

EE

T M

AD

IS

O N

, W I 5

REVISIONS

DWG BY:

4-1-24 23-2176

AG

FI

RE

A

LA

RM

P

LA

N

JOB #

LOWER FLOOR AREA B FLOOR FIRE ALARM PLAN

1/8" = 1'-0"

OVERALL KEY PLAN

N.T.S.

LOWER

FLOOR

AREA B

FIRE

ALARM

PLAN

FA100B

WIRE LEGEND

FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)

FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)

(NAC POWER)

FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)

(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)

FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)

FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)

FF CAT6 (DATA/PHONE)

FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)

ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND

PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE

PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.

S

SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO BOTTOM

(EDWARDS: G4SVWF WITH GRSW-10)

S

HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-HRD WITH SIGA-SB4)

S

H

CONTROL RELAY - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CR)CR

SINGLE MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT1)CT1

DUAL MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT2)CT2

CONTROL MODULE WITH SYNC - DOUBLE GANG 21

2" DEEP (EDWARDS : SIGA-CC1S)CC1S

FLOW SWITCH - BY OTHERSFS

TAMPER SWITCH - BY OTHERSTS

*AREA OF WORK = 214,027 SQ. FEET

*OCCUPANCY TYPE - S-2

APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)

BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)

ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT

(FUNCTIONAL DEVICES : RIBU1C)RIB

50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50

FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP

(EDWARDS : EST4)FACP

DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL

SYMBOL LEGEND:

SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-OSD WITH SIGA-SB4)

SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO

BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)

DENOTES ELEVATOR RECALLER

RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX

PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP

B.3

FIRE COMMAND

CENTER

TRASH

PARCEL

STORAGE

MENS

WOMENS

HOUSING

MAINTENANCE

OFFICE

VESTIBULE

RECEPTION

TV LOUNGE

LOUNGE

STAIR 01

1S01

TLT

192BUS WAITING

TLT

BUS WAITING -

INTERIOR

EXIT PASSAGE

OFFICE

MAIL

CAFE

GAME ROOM

RESIDENT

PARKING

ELEV 01

1E01

STAIR 04

1S04

ELEVATOR

LOBBY

ELEVATOR 04

1E04

ELEVATOR 02

1E02

ELEVATOR

LOBBY

STAIR 02

1S02

GENERATOR

MDF

CORRIDOR

BUS TERMINAL

SEATING

OFFICE

MAINTENANCE

HOUSING

STORAGE

118A

TLT

185A

ENCLAVE

ENCLAVE

ENCLAVE

ENCLAVE

OFFICE

OFFICE

OFFICE

D1

D1

D1

D1

D1

D1

D1

D1

D1

D1D1

D1 D1

SA2

1W 110CD

V29

WP

SA2

1W 110CD

V29

WP

AP

S1

FA

CPAA501-2-138

1-2-137

1-2-136 1-2-135 A2 1-2-134

BP

S1

(1)FB TO BPS#1

MATCHLINE

NOT IN SCOPE

SEE THEORY MADISON FIRE ALARM DRAWINGS

CC1

CC1

CC1 A1B STAIRS 2

A1A STAIRS 3

A1

1-2-189 1-2-190 1-2-192

#1

#1

1-2-148

AA30

CC1S

CC1S

LOWER FL.

1ST FL.

A

B

DATE:

O re go n

C en te r D r.

O re go n, W

I 5

Te l:

8.

9.

Fa x:

.8

.1 w w w .o m ni te ch no lo gi es llc .c om

ST

AT

E

ST

R

EE

T C

AM

PU

S G

AR

AG

E

N

O

RT

H

LA

KE

S

TR

EE

T M

AD

IS

O N

, W I 5

REVISIONS

DWG BY:

4-1-24 23-2176

AG

FI

RE

A

LA

RM

P

LA

N

JOB #

FIRST FLOOR AREA A FLOOR FIRE ALARM PLAN

1/8" = 1'-0"

OVERALL KEY PLAN

N.T.S.

FIRST

FLOOR

AREA A

FIRE

ALARM

PLAN

FA101A

WIRE LEGEND

FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)

FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)

(NAC POWER)

FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)

(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)

FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)

FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)

FF CAT6 (DATA/PHONE)

FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)

ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND

PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE

PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.

S

SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO BOTTOM

(EDWARDS: G4SVWF WITH GRSW-10)

S

HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-HRD WITH SIGA-SB4)

S

H

CONTROL RELAY - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CR)CR

SINGLE MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT1)CT1

DUAL MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT2)CT2

CONTROL MODULE WITH SYNC - DOUBLE GANG 21

2" DEEP (EDWARDS : SIGA-CC1S)CC1S

FLOW SWITCH - BY OTHERSFS

TAMPER SWITCH - BY OTHERSTS

*AREA OF WORK = 214,027 SQ. FEET

*OCCUPANCY TYPE - S-2

APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)

BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)

ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT

(FUNCTIONAL DEVICES : RIBU1C)RIB

50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50

FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP

(EDWARDS : EST4)FACP

DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL

SYMBOL LEGEND:

SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-OSD WITH SIGA-SB4)

SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO

BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)

DENOTES ELEVATOR RECALLER

RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX

PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP

PUBLIC PARKING

4.95%

PARKING

BOOTH

1 2 2.6 2.93 4 5 6 7 8

FIRE PUMP &

WATER/

SPRINKLER

SERVICE

PLUMBING

EQUIPMENT

STUDY LOUNGE

LOUNGE

PUBLIC PARKING

180STAIR 05

1S05

ELEVATOR

LOBBY

ELEVATOR 03

1E03

STAIR 03

1S03

EXIT PASSAGE

CITY DEMARK

ROOM

CITY ELECTRICAL

ROOM

HOUSING

ELECTRICAL

ROOM

CITY OFFICE

TLT

181A

OFFICE

OFFICE

OFFICE

WORK ROOM

STUDY ROOM

STUDY ROOM

STUDY ROOM

D1

D1

D1

D1

D1

D1

D1

D1

D1

D1

D1

D1 D1

SA2

1W 30CD

V1

SA2

1W 110CD

V1

WP

SA2

1W 15CD

V1

2SA2

1W 30CD

V1

SA2

1W 110CD

V1

WP

SA2

1W 110CD

V1

WP

SA2

1W

30CD

V1-EOL

SA2

1W 75CD

V29

SA2

1W 15CD

V29

1-2-20S

(1)FB TO APS#1

ER

SA2

1W 110CD

V29-EOL

WP

SA2

1W 110CD

V29

WP

MATCHLINE

SA2

1W 75CD

V29

A

B

DATE:

O re go n

C en te r D r.

O re go n, W

I 5

Te l:

8.

9.

Fa x:

.8

.1 w w w .o m ni te ch no lo gi es llc .c om

ST

AT

E

ST

R

EE

T C

AM

PU

S G

AR

AG

E

N

O

RT

H

LA

KE

S

TR

EE

T M

AD

IS

O N

, W I 5

REVISIONS

DWG BY:

4-1-24 23-2176

AG

FI

RE

A

LA

RM

P

LA

N

JOB #

FIRST FLOOR AREA B FLOOR FIRE ALARM PLAN

1/8" = 1'-0"

OVERALL KEY PLAN

N.T.S.

FIRST

FLOOR

AREA B

FIRE

ALARM

PLAN

FA101B

WIRE LEGEND

FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)

FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)

(NAC POWER)

FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)

(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)

FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)

FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)

FF CAT6 (DATA/PHONE)

FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)

ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND

PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE

PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.

S

SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO BOTTOM

(EDWARDS: G4SVWF WITH GRSW-10)

S

HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-HRD WITH SIGA-SB4)

S

H

CONTROL RELAY - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CR)CR

SINGLE MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT1)CT1

DUAL MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT2)CT2

CONTROL MODULE WITH SYNC - DOUBLE GANG 21

2" DEEP (EDWARDS : SIGA-CC1S)CC1S

FLOW SWITCH - BY OTHERSFS

TAMPER SWITCH - BY OTHERSTS

*AREA OF WORK = 214,027 SQ. FEET

*OCCUPANCY TYPE - S-2

APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)

BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)

ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT

(FUNCTIONAL DEVICES : RIBU1C)RIB

50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50

FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP

(EDWARDS : EST4)FACP

DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL

SYMBOL LEGEND:

SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-OSD WITH SIGA-SB4)

SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO

BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)

DENOTES ELEVATOR RECALLER

RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX

PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP

B.3

C

D

E

F

STAIR 02

2S02

STAIR 01

2S01

ELEVATOR 01

2E01

PUBLIC PARKING

ELEVATOR 04

2E04

STAIR 04

2S04 ELEVATOR

LOBBY

ELEVATOR 02

2E02

ELEVATOR

LOBBY

MEP

L-G1

NL1-1

L-G1

NL1-1

L-G2

NL1-1

L-G2

NL1-1

L-G3

NL1-1

L-G3

NL1-1

L-C

NL1-1

L-C

NL1-1

L-C

NL1-1

L-F

NL1-1

L-F

NL1-1

L-F

NL1-1

L-F

NL1-1

L-F

NL1-1

L-F

NL1-1

L-F

NL1-1

L-F

NL1-1

L-F

NL1-1

SA3

1W 15CD

V30-EOL

SA3

1W 110CD

V30

WP

SA3

1W 110CD

V30

WP

SA3

1W 110CD

V30

WP SA3

1W 110CD

V30

WP

SA3

1W 110CD

V30

WP SA3

1W 110CD

V2-EOL

WP

1-2-55 S

1-2-166CT2 1-2-165

1-2-164CT2 1-2-163

ER

FS

TS

FS

TS

S9 1W 15cd

V30-EOL

SA3

1W 15cd

V30

WP

MATCHLINE

1-2-193 1-2-194

1-2-50S

1-2-51S

1-2-175

1-2-176CT2

FS

TS

CT2

FS

TS

OPEN TO BELOW

(1)FB TO BPS#2

SA3

1W 15cd

V30

A

B

DATE:

O re go n

C en te r D r.

O re go n, W

I 5

Te l:

8.

9.

Fa x:

.8

.1 w w w .o m ni te ch no lo gi es llc .c om

ST

AT

E

ST

R

EE

T C

AM

PU

S G

AR

AG

E

N

O

RT

H

LA

KE

S

TR

EE

T M

AD

IS

O N

, W I 5

REVISIONS

DWG BY:

4-1-24 23-2176

AG

FI

RE

A

LA

RM

P

LA

N

JOB #

SECOND FLOOR AREA A FLOOR FIRE ALARM PLAN

1/8" = 1'-0"

OVERALL KEY PLAN

N.T.S.

SECOND

FLOOR

AREA A

FIRE

ALARM

PLAN

FA102A

WIRE LEGEND

FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)

FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)

(NAC POWER)

FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)

(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)

FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)

FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)

FF CAT6 (DATA/PHONE)

FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)

ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND

PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE

PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.

S

SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO BOTTOM

(EDWARDS: G4SVWF WITH GRSW-10)

S

HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-HRD WITH SIGA-SB4)

S

H

CONTROL RELAY - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CR)CR

SINGLE MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT1)CT1

DUAL MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT2)CT2

CONTROL MODULE WITH SYNC - DOUBLE GANG 21

2" DEEP (EDWARDS : SIGA-CC1S)CC1S

FLOW SWITCH - BY OTHERSFS

TAMPER SWITCH - BY OTHERSTS

*AREA OF WORK = 214,027 SQ. FEET

*OCCUPANCY TYPE - S-2

APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)

BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)

ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT

(FUNCTIONAL DEVICES : RIBU1C)RIB

50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50

FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP

(EDWARDS : EST4)FACP

DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL

SYMBOL LEGEND:

SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-OSD WITH SIGA-SB4)

SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO

BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)

DENOTES ELEVATOR RECALLER

RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX

PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP

G

H

I

J

K

ELEVATOR

LOBBY

ELEVATOR 03

2E03

STAIR 03

2S03

MEP

STAIR 05

2S05

HA11-EM(8')

EMH1-7 HA11-EM(4')

EMH1-7

HA11-EM(4')

EMH1-7

HA12-EM

EMH1-6

HA12-EM

EMH1-6

L-B

NL1-1

L-B

NL1-1

L-B

NL1-1

L-F

NL1-1

L-F

NL1-1

L-F

NL1-1

L-F

NL1-1

L-F

NL1-1

L-F

NL1-1

SA3

1W 110CD

V30

WP SA3

1W 110CD

V2-EOL

WP

SA3

1W 110CD

V2

WP

SA3

1W 110CD

V2

WP

SA3

1W 110CD

V2

WP

SA3

1W 110CD

V2

WP

SA3

1W 15CD

V2

1-2-56 S

(1)FB TO APS#2

ER

SA3

2W 75cd

V2

1-2-11S

1-2-171 1-2-172

MATCHLINE

CT2

FS

TS

(1)FB TO BPS#2

A

B

DATE:

O re go n

C en te r D r.

O re go n, W

I 5

Te l:

8.

9.

Fa x:

.8

.1 w w w .o m ni te ch no lo gi es llc .c om

ST

AT

E

ST

R

EE

T C

AM

PU

S G

AR

AG

E

N

O

RT

H

LA

KE

S

TR

EE

T M

AD

IS

O N

, W I 5

REVISIONS

DWG BY:

4-1-24 23-2176

AG

FI

RE

A

LA

RM

P

LA

N

JOB #

SECOND FLOOR AREA B FLOOR FIRE ALARM PLAN

1/8" = 1'-0"

OVERALL KEY PLAN

N.T.S.

SECOND

FLOOR

AREA B

FIRE

ALARM

PLAN

FA102B

WIRE LEGEND

FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)

FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)

(NAC POWER)

FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)

(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)

FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)

FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)

FF CAT6 (DATA/PHONE)

FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)

ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND

PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE

PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.

S

SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO BOTTOM

(EDWARDS: G4SVWF WITH GRSW-10)

S

HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-HRD WITH SIGA-SB4)

S

H

CONTROL RELAY - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CR)CR

SINGLE MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT1)CT1

DUAL MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT2)CT2

CONTROL MODULE WITH SYNC - DOUBLE GANG 21

2" DEEP (EDWARDS : SIGA-CC1S)CC1S

FLOW SWITCH - BY OTHERSFS

TAMPER SWITCH - BY OTHERSTS

*AREA OF WORK = 214,027 SQ. FEET

*OCCUPANCY TYPE - S-2

APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)

BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)

ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT

(FUNCTIONAL DEVICES : RIBU1C)RIB

50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50

FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP

(EDWARDS : EST4)FACP

DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL

SYMBOL LEGEND:

SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-OSD WITH SIGA-SB4)

SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO

BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)

DENOTES ELEVATOR RECALLER

RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX

PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP

B.3

C

D

E

F

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1HA11-EM(4')

EML1-1

HA16-EM

EML1-1

HA11-EM(8')

EML1-1

HA11-EM(8')

EML1-1

L-S

L-T

NLP5-1

L-T

NLP5-1

L-T

NLP5-1

L-T

NLP5-1

L-T

NLP5-1

L-S

L-S

NLP5-1

EML1-1

EML1-1EML1-1

NLP5-1

EML1-1

NLP5-1

SA4

1W 110CD

V3

WP

SA4

1W 110CD

V3

WP

SA4

1W 110CD

V3

WP

SA4

1W 110CD

V3-EOL

WP

SA4

1W 110CD

V31 - EOL

WP

SA4

1W 110CD

V3

WP

SA4

1W 15CD

V3

1-2-53 S

1-2-162CT2 1-2-161

1-2-133 1-2-132 1-2-131 1-2-130

A3

A4

CC1S1-2-129

AP

S1

1-2-2S

AA30

ER

FS

TS

1-2-139 1-2-140

1-2-4S

SA4

1W 15cd

V3

N O

T

IN

S C

O

PE

N

T

IN

S

C

SE

E

TH

EO

R Y

M

AD

IS

O

N F

IR

E

AL

AR

M D

R

AW

IN

G

S

MATCHLINE

S 1W A1A

CT2

FS

TS

#2

(1)FB TO BPS#2

BP

S1

#2

CC1S1-2-177

2ND FL.

3RD FL.

AA30

A

B

DATE:

O re go n

C en te r D r.

O re go n, W

I 5

Te l:

8.

9.

Fa x:

.8

.1 w w w .o m ni te ch no lo gi es llc .c om

ST

AT

E

ST

R

EE

T C

AM

PU

S G

AR

AG

E

N

O

RT

H

LA

KE

S

TR

EE

T M

AD

IS

O N

, W I 5

REVISIONS

DWG BY:

4-1-24 23-2176

AG

FI

RE

A

LA

RM

P

LA

N

JOB #

THIRD FLOOR AREA A FLOOR FIRE ALARM PLAN

1/8" = 1'-0"

OVERALL KEY PLAN

N.T.S.

THIRD

FLOOR

AREA A

FIRE

ALARM

PLAN

FA103A

WIRE LEGEND

FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)

FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)

(NAC POWER)

FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)

(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)

FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)

FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)

FF CAT6 (DATA/PHONE)

FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)

ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND

PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE

PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.

S

SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO BOTTOM

(EDWARDS: G4SVWF WITH GRSW-10)

S

HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-HRD WITH SIGA-SB4)

S

H

CONTROL RELAY - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CR)CR

SINGLE MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT1)CT1

DUAL MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT2)CT2

CONTROL MODULE WITH SYNC - DOUBLE GANG 21

2" DEEP (EDWARDS : SIGA-CC1S)CC1S

FLOW SWITCH - BY OTHERSFS

TAMPER SWITCH - BY OTHERSTS

*AREA OF WORK = 214,027 SQ. FEET

*OCCUPANCY TYPE - S-2

APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)

BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)

ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT

(FUNCTIONAL DEVICES : RIBU1C)RIB

50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50

FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP

(EDWARDS : EST4)FACP

DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL

SYMBOL LEGEND:

SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-OSD WITH SIGA-SB4)

SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO

BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)

DENOTES ELEVATOR RECALLER

RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX

PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP

G

H

I

J

K

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

C1-EM

EML1-1

HA11-EM(4')

EML1-1

C1-EM

EML1-1

HA12-EM

EMH1-6

HA12-EM

EMH1-6

L-T

NLP5-1

L-T

NLP5-1

L-T

NLP5-1

L-T

NLP5-1

L-S

L-S

EML1-1

NLP5-1

EML1-1EML1-1

NLP5-1

EML1-1

EML1-1

SA4

1W 110CD

V31 - EOL

WP

SA4

1W 110CD

V31

WP

SA4

1W 110CD

V31

WPSA4

1W 110CD

V31

WP

SA4

1W 110CD

V31

WP

SA4

1W 110CD

V3

WP

SA4

1W 15CD

V31

1-2-54 S

ER

N O

T

IN

S C

TH

EO

R

Y M

AD

IS

O N

F

IR

E

AL

AR

M

D R

AW

IN

G S

N O

T

IN

S C

MATCHLINE

1W A1B

(1)FB TO BPS#2

(1)FB TO BPS#2

A

B

DATE:

O re go n

C en te r D r.

O re go n, W

I 5

Te l:

8.

9.

Fa x:

.8

.1 w w w .o m ni te ch no lo gi es llc .c om

ST

AT

E

ST

R

EE

T C

AM

PU

S G

AR

AG

E

N

O

RT

H

LA

KE

S

TR

EE

T M

AD

IS

O N

, W I 5

REVISIONS

DWG BY:

4-1-24 23-2176

AG

FI

RE

A

LA

RM

P

LA

N

JOB #

THIRD FLOOR AREA B FLOOR FIRE ALARM PLAN

1/8" = 1'-0"

OVERALL KEY PLAN

N.T.S.

THIRD

FLOOR

AREA B

FIRE

ALARM

PLAN

FA103B

WIRE LEGEND

FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)

FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)

(NAC POWER)

FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)

(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)

FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)

FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)

FF CAT6 (DATA/PHONE)

FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)

ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND

PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE

PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.

S

SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO BOTTOM

(EDWARDS: G4SVWF WITH GRSW-10)

S

HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-HRD WITH SIGA-SB4)

S

H

CONTROL RELAY - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CR)CR

SINGLE MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT1)CT1

DUAL MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT2)CT2

CONTROL MODULE WITH SYNC - DOUBLE GANG 21

2" DEEP (EDWARDS : SIGA-CC1S)CC1S

FLOW SWITCH - BY OTHERSFS

TAMPER SWITCH - BY OTHERSTS

*AREA OF WORK = 214,027 SQ. FEET

*OCCUPANCY TYPE - S-2

APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)

BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)

ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT

(FUNCTIONAL DEVICES : RIBU1C)RIB

50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50

FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP

(EDWARDS : EST4)FACP

DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL

SYMBOL LEGEND:

SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-OSD WITH SIGA-SB4)

SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO

BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)

DENOTES ELEVATOR RECALLER

RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX

PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP

B.3

C

D

E

F

PUBLIC PARKING

STAIR 04

4S04

ELEVATOR

LOBBY

ELEVATOR 04

4E04

STAIR 02

4S02

ELEVATOR 02

4E02

ELEVATOR

LOBBY

STAIR 01

4S01

ELEVATOR 01

4E01

ELEVATOR

LOBBY

UNIT TH6

302U

UNIT TH1A

304U

UNIT TH1B

306U

UNIT TH2

308U

UNIT TH1B

310U

STORAGE

IDF / MDF

HA11-EM(8')

EMH1-7

HA11-EM(8')

EMH1-7

HA11-EM(8')

EMH1-7

HA11-EM(8')

EMH1-7

HA11-EM(4')

EMH1-7

HA11-EM(8')

EMH1-7

HA11-EM(8')

EMH1-7

HA11-EM(8')

EMH1-7

HA11-EM(8')

EMH1-7

HA11-EM(8')

EMH1-7

HA11-EM(8')

EMH1-7

EMH1-7

SA5

1W 110CD

V5

WP

SA5

1W 110CD

V5

WP

SA5

1W 110CD

V5

WP

SA5

1W 110CD

V5-EOL

WP

S13

1W 110CD

V4 - EOL

WP

SA5

1W 110CD

V5

WP

SA5

1W 15CD

V5

1-2-41 S

1-2-160CT2 1-2-159

ER

FS

TS

1-2-52S

1-2-173 1-2-174

SA5

1W 15cd

V5

N O

T

IN

S C

T

IN

S

C

TH

EO

R Y

M

AD

IS

O

N F

IR

E

AL

AR

M D

R

AW

IN

G

S

MATCHLINE

CT2

FS

TS

(1)FB TO APS#3

A

B

DATE:

O re go n

C en te r D r.

O re go n, W

I 5

Te l:

8.

9.

Fa x:

.8

.1 w w w .o m ni te ch no lo gi es llc .c om

ST

AT

E

ST

R

EE

T C

AM

PU

S G

AR

AG

E

N

O

RT

H

LA

KE

S

TR

EE

T M

AD

IS

O N

, W I 5

REVISIONS

DWG BY:

4-1-24 23-2176

AG

FI

RE

A

LA

RM

P

LA

N

JOB #

FOURTH FLOOR AREA A FLOOR FIRE ALARM PLAN

1/8" = 1'-0"

OVERALL KEY PLAN

N.T.S.

FOURTH

FLOOR

AREA A

FIRE

ALARM

PLAN

FA104A

WIRE LEGEND

FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)

FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)

(NAC POWER)

FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)

(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)

FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)

FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)

FF CAT6 (DATA/PHONE)

FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)

ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND

PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE

PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.

S

SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO BOTTOM

(EDWARDS: G4SVWF WITH GRSW-10)

S

HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-HRD WITH SIGA-SB4)

S

H

CONTROL RELAY - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CR)CR

SINGLE MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT1)CT1

DUAL MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT2)CT2

CONTROL MODULE WITH SYNC - DOUBLE GANG 21

2" DEEP (EDWARDS : SIGA-CC1S)CC1S

FLOW SWITCH - BY OTHERSFS

TAMPER SWITCH - BY OTHERSTS

*AREA OF WORK = 214,027 SQ. FEET

*OCCUPANCY TYPE - S-2

APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)

BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)

ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT

(FUNCTIONAL DEVICES : RIBU1C)RIB

50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50

FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP

(EDWARDS : EST4)FACP

DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL

SYMBOL LEGEND:

SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-OSD WITH SIGA-SB4)

SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO

BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)

DENOTES ELEVATOR RECALLER

RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX

PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP

G

H

I

J

K

ELEVATOR

LOBBY

ELEVATOR 03

4E03

STAIR 03

4S03

UNIT TH1B

310U

UNIT TH3

312U

UNIT TH5

316U

UNIT TH4

314U

STAIR 05

4S05

MECH

CLOSET

HA12-EM

EMH1-6

HA12-EM

EMH1-6

HA11-EM(4')

EMH1-7

HA11-EM(4')

EMH1-7

HA11-EM(4')

EMH1-7

EMH1-7

HA11-EM(8')

EMH1-7

HA11-EM(8')

EMH1-7

HA11-EM(8')

EMH1-7

HA11-EM(4')

EMH1-7

HA11-EM(4')

EMH1-7

HA11-EM(8')

EMH1-7

EMH1-7

EMH1-7

EMH1-7

EMH1-7

EMH1-7

WP

SA5

1W 110CD

V4

WP

SA5

1W 110CD

V4

WP

SA5

1W 110CD

V4

WP

SA5

1W 110CD

V4

WP

A5 V5

WP

SA5

1W 15CD

V4

1-2-42 S

ER

N O

T

IN

S C

TH

EO

R

Y M

AD

IS

O N

F

IR

E

AL

AR

M

D R

AW

IN

G S

N O

T

IN

S C

TH

EO

R

Y M

AD

IS

O N

F

IR

E

AL

AR

M

D R

AW

IN

G S

MATCHLINE

(1)FB TO APS#3

A

B

DATE:

O re go n

C en te r D r.

O re go n, W

I 5

Te l:

8.

9.

Fa x:

.8

.1 w w w .o m ni te ch no lo gi es llc .c om

ST

AT

E

ST

R

EE

T C

AM

PU

S G

AR

AG

E

N

O

RT

H

LA

KE

S

TR

EE

T M

AD

IS

O N

, W I 5

REVISIONS

DWG BY:

4-1-24 23-2176

AG

FI

RE

A

LA

RM

P

LA

N

JOB #

FOURTH FLOOR AREA B FLOOR FIRE ALARM PLAN

1/8" = 1'-0"

OVERALL KEY PLAN

N.T.S.

FOURTH

FLOOR

AREA B

FIRE

ALARM

PLAN

FA104B

WIRE LEGEND

FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)

FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)

(NAC POWER)

FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)

(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)

FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)

FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)

FF CAT6 (DATA/PHONE)

FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)

ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND

PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE

PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.

S

SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21

8" DEEP, 84" AFF TO BOTTOM

(EDWARDS: G4SVWF WITH GRSW-10)

S

HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE

(EDWARDS : SIGA-HRD WITH SIGA-SB4)

S

H

CONTROL RELAY - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CR)CR

SINGLE MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT1)CT1

DUAL MONITOR MODULE - SINGLE GANG 21

2" DEEP (EDWARDS : SIGA-CT2)CT2

CONTROL MODULE WITH SYNC - DOUBLE GANG 21

2" DEEP (EDWARDS : SIGA-CC1S)CC1S

FLOW SWITCH - BY OTHERSFS

TAMPER SWITCH - BY OTHERSTS

*AREA OF WORK = 214,027 SQ. FEET

*OCCUPANCY TYPE - S-2

APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)

BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)

ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT

(FUNCTIONAL DEVICES : RIBU1C)RIB

50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50

FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP

(EDWARDS : EST4)FACP

DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL

SYMBOL LEGEND:

SMOKE DETECTOR…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .