Addendum 2_Attachment 2.pdf
PDF 19 MB Posted
- Attached to
- Intrusion and Fire Alarms
- Solicitation number
- 13060-0-2025-BP
- Issued by
- Dane County, Mattoon Village, Wisconsin
About this file
I apologize, but I don't see the actual contents of "Addendum 2_Attachment 2.pdf" in the provided text. While I can see that this file is related to an Intrusion and Fire Alarms contract opportunity in Wisconsin, I cannot provide a summary of its contents without access to the actual document. To provide an accurate summary, I would need to see the contents or text within the addendum attachment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Addendum 2_Attachment 5.pdf | ||
| Addendum 2_Attachmen 1.pdf | ||
| 13060 Addendum 1.pdf | ||
| 13060 Addendum 2.pdf | ||
| 13060-0-2025-BP Intrustion and Fire Alarms.pdf | ||
| 13060 Summary.pdf | ||
| Addendum 2_Attachment 3.pdf | ||
| 13060-Form D2.xlsx | XLSX spreadsheet | |
| 13060-Appendix C.xlsx | XLSX spreadsheet | |
| Addendum 2_Attachment 4.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5525 Nobel Drive, Suite 110 | Madison, WI 53711 | 608.277.1728 | www.jdrengineering.com
SHOP DRAWING REVIEW
This review is limited to checking for general conformance with the design concept, and for general compliance with information given in the Construction Documents. Corrections or comments made on these shop drawings do not relieve the contractor from the obligation to comply with the requirements of the drawings and specifications. Approval of a specific item shall not constitute approval of an assembly in which the item is a component. Contractor is responsible for: confirming and correlating all dimensions and quantities; information that pertains solely to the fabrication processes; the means, methods, techniques, sequences and procedures of construction; performing work in a safe and satisfactory manner; and coordinating work with that of all other trades.
Project Name: SSCG Phase 1 Date: 05/16/2024
Project No: 22.0249 Reviewed By: Joe Mullvain
Description: 28 46 21 Fire Alarm
A p p ro v e d p ro v e d a s
C o rr e ct
R
-v is e a n d
R e su b m it je ct ed
S u b m it S p e ci fi e d
I te b m it ta l N o t
R e q u e st e d
R e tu rn n o t
R e v ie w
Item No. References Comments
☒ ☐ ☐ ☐ ☐ ☐ 1 Floor Plans, Details &
Riser Diagrams
Reviewed for general compliance and project scope.
Contractor shall verify all code required aspects and submit drawings and specifications to the local AHJ for approval.
☒ ☐ ☐ ☐ ☐ ☐ 2 Controller Module No objections.
☒ ☐ ☐ ☐ ☐ ☐ 3 Control Relay No objections.
☒ ☐ ☐ ☐ ☐ ☐ 4 Aux Power Supply No objections.
☒ ☐ ☐ ☐ ☐ ☐ 5 Booster Power Supply No objections.
☒ ☐ ☐ ☐ ☐ ☐ 6 Audio Amplifier No objections.
☒ ☐ ☐ ☐ ☐ ☐ 7 Lead Acid Battery No objections.
☒ ☐ ☐ ☐ ☐ ☐ 8 Wall Mount Speaker /
Speaker Strobe No objections.
☒ ☐ ☐ ☐ ☐ ☐ 9 Ceiling Mount Speaker /
Speaker Strobe No objections.
☒ ☐ ☐ ☐ ☐ ☐ 10 Manual Pull Station No objections.
☒ ☐ ☐ ☐ ☐ ☐ 11 Heat Detector No objections.
☒ ☐ ☐ ☐ ☐ ☐ 12 Smoke Detector No objections.
☒ ☐ ☐ ☐ ☐ ☐ 13 Smoke Detector / CO
Sensor No objections.
☒ ☐ ☐ ☐ ☐ ☐ 14 Signal Module No objections.
☒ ☐ ☐ ☐ ☐ ☐ 15 Output Module No objections.
Re: Lake St Development Page #2 p ro v p ro v e d a s
C o rr e ct
-v is e a n d
R e su b it je ct ed b m it S p e ci fi e d
I te b m it ta l N o t
R e q u e st e d
R e tu rn n o t
R e v ie w
Item No. References Comments
☒ ☐ ☐ ☐ ☐ ☐ 16 Control Relay Module No objections.
☒ ☐ ☐ ☐ ☐ ☐ 17 Input Module No objections.
☒ ☐ ☐ ☐ ☐ ☐ 18
Voltage Drop, Battery Calculations, Amplifier
Calculations, & Address ID’s
Reviewed for general compliance and project scope.
Contractor shall verify all code required aspects and submit drawings and specifications to the local AHJ for approval.
☐ ☐ ☐ ☐ ☐ ☐ 19
☐ ☐ ☐ ☐ ☐ ☐ 20
9361-State St Campus Garage Mixed-Use Project-CONS #126-Fire Alarm SD & PD
Created by Joe Mullvain with Autodesk® Construction Cloud™ on May 16, 2024 at 2:08 PM CDT Page 1 of 3
Submittal item detail
#28 46 21-126-0: Fire Alarm SD & PD
Status Created on Due date
Open In Review
Mar 4, 2024 May 17, 2024
ID 229
Ball in court Joe Mullvain (JDR Engineering Inc.)
Michael Jochman (JDR Engineering Inc.)
Rachel Steffen (EUA (Eppstein Uhen Architects, Inc.))
DESIGN-A/E-PROJ MGR
Manager DESIGN-A/E-PROJ MGR
Responsible contractor CONTRACTOR-GC-PROJ MGR
Watchers PROJECT USERS
Spec section 28 46 21 Electronic Safety and Security
Spec sub section
Description Fire Alarm SD & PD
Final Response
Final Response Attachments
Final Response Comments
Package https://acc.autodesk.com/build/submittals/projects/096dc208-2e01-49e8-ae16-9afe0638c914/items?preview=de3b597c-ff13-4a65-9826-a205c40bb12f&tab=overview https://acc.autodesk.com/build/submittals/projects/096dc208-2e01-49e8-ae16-9afe0638c914/items?preview=de3b597c-ff13-4a65-9826-a205c40bb12f&tab=overview
Created by Joe Mullvain with Autodesk® Construction Cloud™ on May 16, 2024 at 2:08 PM CDT Page 2 of 3
Ball in court Sent Due Returned Response/Action Attachments
Submitted
CONTRACTOR-GC-PROJ
MGR
Submitted by Tyler Welch
Mar 4, 2024 Jul 7, 2024 May 3, 2024 Submitted 28 46 21-1 Fire Alarm SD & PD.pdf
Comments -
Sent for review
DESIGN-A/E-PROJ MGR
Sent by Todd King
May 3, 2024 Jul 21, 2024 May 10, 2024 Sent for review 28 46 21-1 Fire Alarm SD & PD.pdf
Comments -
Review Step 1
Joe Mullvain (JDR Engineering Inc.)
May 10, 2024 May 16, 2024 -
Comments
Michael Jochman (JDR Engineering Inc.)
May 10, 2024 May 16, 2024 -
Comments
DESIGN-A/E-PROJ MGR May 10, 2024 May 16, 2024 -
Comments
Rachel Steffen May 10, 2024 May 16, 2024 May 15, 2024 Reviewed w/No Comment https://developer.api.autodesk.com/reports/v2/attachments/urn%3Aadsk.wipprod%3Afs.file%3Avf.zQzIJKinQrOAxwApEaf4mQ%3Fversion%3D1?projectId=096dc208-2e01-49e8-ae16-9afe0638c914®ion=US&token=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJkYXRhIjp7InVybiI6InVybjphZHNrLndpcHByb2Q6ZnMuZmlsZTp2Zi56UXpJSktpblFyT0F4d0FwRWFmNG1RP3ZlcnNpb249MSJ9LCJpYXQiOjE3MTU4ODY1MTAsImV4cCI6MTcxODQ3ODUxMH0.dpmt6DORSOHs7u72ZmM07saaQ9f5N2bOFOiMdcLmA9E https://developer.api.autodesk.com/reports/v2/attachments/urn%3Aadsk.wipprod%3Afs.file%3Avf.zQzIJKinQrOAxwApEaf4mQ%3Fversion%3D1?projectId=096dc208-2e01-49e8-ae16-9afe0638c914®ion=US&token=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJkYXRhIjp7InVybiI6InVybjphZHNrLndpcHByb2Q6ZnMuZmlsZTp2Zi56UXpJSktpblFyT0F4d0FwRWFmNG1RP3ZlcnNpb249MSJ9LCJpYXQiOjE3MTU4ODY1MTAsImV4cCI6MTcxODQ3ODUxMH0.dpmt6DORSOHs7u72ZmM07saaQ9f5N2bOFOiMdcLmA9E
Created by Joe Mullvain with Autodesk® Construction Cloud™ on May 16, 2024 at 2:08 PM CDT Page 3 of 3
Ball in court Sent Due Returned Response/Action Attachments
(EUA (Eppstein Uhen Architects, Inc.)) Reviewed By Rachel Steffen
Comments
Review Step 2
COM-ENG-CB/RFI/SUBM
MGR
Comments
SUBMITTAL
TRANSMITTAL
P.O Box 7726 Madison WI 53707 Phone: 608.222.5100
Project: 23-2008-0 State Street Campus Garage
Date Submitted: Response Due:
To: Stevens Construction Corp.
Title:
Type:
Spec:
Requested By:
We are sending:
SUBMITTAL PACKAGE
FOR
STATE STREET CAMPUS GARAGE
FIRE ALARM – SHOP DRAWINGS
SPEC SECTION 28 46 21
Prepared by Electrical Contractor:
NEXT Electric, LLC Arden Parfitt, Senior Project Manager
4009 Felland Rd., Suite 106 Madison, WI 53718
Arden.Parfitt@nextelectricllc.com Ph: (608) 371-1158 Fax: (262) 506-3201 www.nextelectricllc.com mailto:Arden.Parfitt@nextelectricllc.com http://www.nextelectricllc.com/
900 Oregon Center Dr. Oregon, WI 53575 │ O: 608.819.1980 F:608.819.1981 │ www.omnitechnologiesllc.com
NURSE CALL │ FIRE ALARM │ AUDIO/VIDEO │ SECURITY
SUBMITTAL TRANSMITTAL
Sent Via:
Emailed Drop Box
To: Next Electric From: Tom Sweet
Arden Parfitt Project Manager 608-819-6657
Email: arden.parfitt@nextelectricllc.com tsweet@omnitechnologiesllc.com
Project Coordinator kdulaney@omnitechnologiesllc.com
Project: State Street Campus Garage Job# 23-2176-1
Description: 283100 Fire Alarm – Shop Drawing
Original Date: 4/18/24 Revision Date:
Submittal# 1 Revision # mailto:arden.parfitt@nextelectricllc.com mailto:tsweet@omnitechnologiesllc.com mailto:kdulaney@omnitechnologiesllc.com
FIRE
ALARM
TITLE
PAGE
FA000
DATE:
O re go n
C en te r D r.
O re go n, W
I 5
Te l:
8.
9.
Fa x:
.8
.1 w w w .o m ni te ch no lo gi es llc .c om
ST
AT
E
ST
R
EE
T C
AM
PU
S G
AR
AG
E
N
O
RT
H
LA
KE
S
TR
EE
T M
AD
IS
O N
, W I 5
REVISIONS
DWG BY:
4-1-24 23-2176
AG
FI
RE
A
LA
RM
P
LA
N
JOB #
WIRING SELECTION & GUIDELINES
PLENUM CABLE VS. NON-PLENUM
THE NEC RECOGNIZES 3 TYPES OF POWER LIMITED FIRE ALARM CABLING:
FPL - THIS IS A GENERAL USE POWER LIMITED FIRE ALARM CABLING. IT
CANNOT BE USED IN A PLENUM SPACE OR FOR RISERS (CABLING
BETWEEN FLOORS).
FPLR - THIS IS A POWER LIMITED RISER RATED CABLE THAT CAN BE USED
FOR GENERAL PURPOSES OR BETWEEN FLOORS. IT CANNOT BE USED
IN A PLENUM SPACE.
FPLP - THIS IS A POWER LIMITED CABLE THAT CAN BE USED IN A PLENUM,
RISER, OR FOR GENERAL PURPOSES.
A PLENUM IS AN AREA USED TO CONDUCT ENVIRONMENTAL AIR. PLENUM
SPACES CAN BE DUCTWORK, THE SPACE ABOVE A DROP CEILING, OR
BELOW A RAISED FLOOR. BECAUSE THESE SPACES ARE BEING USED FOR
THE AIR HANDLING SYSTEM THERE ARE STRICT RULES THAT MUST BE
FOLLOWED TO REDUCE THE RISK OF INTRODUCING TOXIC FUMES IN THE
EVENT OF A FIRE. SINCE FIRE ALARM CABLING IS OFTEN INSTALLED
EXPOSED, WITHOUT, CONDUIT, ABOVE DROP CEILINGS THE CABLING
MUST BE RATED FOR USE IN A PLENUM SPACE.
CIRCUIT MARKING NEC (NFPA 70) ARTICLE 760.42
THE EQUIPMENT SHALL BE DURABLY MARKED WHERE PLAINLY VISIBLE TO
INDICATE EACH CIRCUIT THAT IS POWER-LIMITED FIRE ALARM CIRCUIT.
EXCEPTION WHERE A POWER-LIMITED CIRCUIT IS TO BE RECLASSIFIED AS
A NON-POWER-LIMITED CIRCUIT.
SUPPORT OF CONDUCTORS PER NEC (NFPA 70) ARTICLE 760.57
POWER-LIMITED FIRE ALARM CIRCUIT CONDUCTORS SHALL NOT BE
STRAPPED, TAPED, OR ATTACHED BY ANY MEANS TO THE EXTERIOR OF
ANY CONDUIT OR OTHER RACEWAY AS A MEANS OF SUPPORT.
WIRE ROUTING
NEC (NFPA 70) ARTICLE 760.5 SEPARATION FROM ELECTRIC LIGHT POWER,
CLASS 1, NPLFA, AND MEDIUM POWER NETWORK-POWERED BROADBAND
COMMUNICATIONS CIRCUIT CONDUCTORS.
(A) GENERAL POWER-LIMITED FIRE ALARM CIRCUIT CABLES AND
CONDUCTORS SHALL NOT BE PLACED IN ANY CABLE, CABLE TRAY,
COMPARTMENT, ENCLOSURE, MANHOLE, OUTLET BOX, DEVICE BOX,
RACEWAY, OR SIMILAR FITTING WITH CONDUCTORS OF ELECTRIC LIGHT,
POWER, CLASS 1, BROADBAND COMMUNICATIONS CIRCUITS UNLESS
PERMITTED BY 760.55
IN HOISTWAYS POWER-LIMITED FIRE ALARM CIRCUIT CONDUCTORS SHALL
BE INSTALLED IN RIGID METAL CONDUIT, RIGID NONMETALLIC CONDUIT,
INTERMEDIATE METAL CONDUIT, LIQUID TIGHT FLEXIBLE NONMETALLIC
CONDUIT OR ELECTRICAL METALLIC TUBING FOR ELEVATORS OR SIMILAR
EQUIPMENT. THESE CONDUCTORS SHALL BE PERMITTED TO BE
INSTALLED AS PROVIDED IN 620.21
NEC (NFPA 70) ARTICLE 760.61 APPLICATION OF LISTED PLFA CABLES,
PLFA CABLES SHALL COMPLY WITH THE REQUIREMENTS DESCRIBED IN
EITHER 760.61 (A), (B) OR (C) OR WHERE CABLE SUBSTITUTIONS ARE MADE
AS SHOWN IN 760.61 (D).
CABLES INSTALLED IN DUCTS, PLENUMS, AND OTHER SPACES USED FOR
ENVIRONMENTAL AIR SHALL BE TYPE FPLP. ABANDONED CABLES SHALL
NOT BE PERMITTED TO REMAIN. TYPES FPLP, FPLR, AND FPL CABLES
INSTALLED IN COMPLIANCE WITH 300.22 SHALL BE PERMITTED.
CABLES INSTALLED IN VERTICAL RUNS AND PENETRATING MORE THAN
ONE FLOOR, OR CABLES INSTALLED IN VERTICAL RUNS IN A SHAFT, SHALL
BE TYPE FPLR. FLOOR PENETRATIONS REQUIRING TYPE FPLR SHALL
CONTAIN ONLY CABLES SUITABLE FOR RISER OR PLENUM USE.
ABANDONED CABLES SHALL NOT BE PERMITTED TO REMAIN.
SHIELDED CABLE
IF SHIELDED CABLE IS USED, THE SHIELDS SHALL BE SPLICED THROUGH
AT EACH JUNCTION. SHIELDS SHALL BE SEPARATED FROM ALL OTHER
CONDUCTORS, AND TAPED WHEN SPLICED THROUGH TO PREVENT
GROUNDING OF THE SHIELD IN THE FIELD. THE SHIELD SHALL BE LEFT
FLOATING AT THE LAST DEVICE. ALL SHIELDS WILL BE GROUNDED AT THE
CONTROL PANEL(S), AND ONLY AT THE CONTROL PANEL(S).
PARTIAL EVACUATION & CABLE SURVIVABILITY
IF RELOCATION OR PARTIAL EVACUATION OF BUILDING OCCUPANTS IS TO
BE USED UPON ACTIVATION OF A FIRE ALARM, CABLE SURVIVABILITY
REQUIREMENTS MUST BE FOLLOWED. WHERE NOTIFICATION ZONES ARE
SEPARATED BY LESS THE TWO-HOUR FIRE-RATED CONSTRUCTION,
A PATHWAY SURVIVABILITY OF LEVEL 1, 2 OR 3 SHALL BE PERMITTED.
CABLE TO BE INSTALLED PER THE REQUIREMENTS OF NFPA 72
CHAPTER 24.
REVIEWED BY:
MIKE RESS
CHECK LIST FOR START UP
THE FOLLOWING IS A LIST OF CRITERIA THAT MUST BE MET PRIOR TO START UP
- MARK UP THE OMNI TECHNOLOGIES, LLC. DRAWINGS SHOWING
- THE ACTUAL WIRE RUNS AND ANY DISCREPENCIES/CHANGES
BETWEEN THE ACTUAL CONDITIONS, LOCATIONS, WIRE RUNS
AND THE SYSTEM DRAWINGS SHOULD BE NOTATED FOR
INCLUSION ON THE FINAL AS-BUILT DRAWING OF RECORD.
- ALL DEVICES HAVE BEEN INSTALLED AND TERMINATED
PROPERLY
- CONTACT OMNI TECHNOLOGIES, LLC. PROJECT MANAGER
FIFTEEN BUSINESS DAYS PRIOR TO SCHEDULED START-UP
- IF YOUR SYSTEM IS BEING FURNISHED WITH A DIALER, (2) RJ31X
PHONE JACKS MUST BE INSTALLED WITHIN 3 FT. OF THE FACP.
THESE PHONE LINES MUST BE CONNECTED BEFORE ALL
BUILDING PHONE EQUIPMENT, (NO "9" PREFIX), AND SHOULD
HAVE NO DIAL-OUT RESTRICTIONS. PROVIDE THE OMNI
TECHNOLOGIES, LLC. PROJECT MANAGER WITH A CUSTOMER
EMERGENCY CALL. LIST. IF THE MONITORING IS NOT PROVIDED
BY OMNI TECHNOLOGIES, LLC. THEN FOLLOWING INFORMATION
MUST ALSO BE OBTAINED PRIOR TO START UP: CENTRAL
STATION ACCOUNT NUMBER, RECEIVER PHONE NUMBERS,
CENTRAL STATION VOICE LINE NUMBER, AND ALARM COMPANY
PHONE NUMBER.
- ALL FIELD DEVICES, SMOKE DETECTORS, MONITOR MODULES,
CONTROL MODULES NOTIFICATION APPLIANCES BOTH VISUAL
AND AUDIBLE ARE ADDRESSED AND OUTPUT SET (AS REQUIRED)
AND INSTALLED.
CHECK FIELD WIRING WITH AN OHM METER:
- MEASURE EACH CONDUCTOR OF THE ADDRESSABLE LOOP (SLC)
TO GROUND, CONDUCTOR TO CONDUCTOR, CONDUCTOR TO
SHIELD, AND SHIELD TO EARTH. THE RESISTANCE SHOULD BE
GREATER THAN 1 MEGA OHM. NOTE LINE TO LINE
MEASUREMENTS REQUIRE ONE END OF THE PAIR TO BE
SHORTED. STRAY VOLTAGE SHOULD BE LESS THAN 1 VDC/AC.
RECORD THE READINGS
- MEASURE EACH CONDUCTOR OF THE NOTIFICATION APPLIANCE
CIRCUIT (NAC) TO GROUND, AND CONDUCTOR TO CONDUCTOR.
THE RESISTANCE SHOULD BE GREATER THAN 1 MEGA OHM,
WITHOUT THE END OF LINE RESISTOR, STRAY VOLTAGES
SHOULD BE LESS THAN 1 VDC/AC
- MEASURE ACROSS THE CONDUCTORS OF A NOTIFICATION
APPLIANCE CIRCUIT (NAC), YOUR READING SHOULD BE
EQUIVALENT TO THE VALUE OF THE END OF THE LINE RESISTOR
INSTALLED AT THE LAST DEVICE. IF THE MEASUREMENTS ARE
NOT WITHIN THE ACCEPTABLE VALUES, THE CIRCUIT WIRING HAS
A SHORT OR AN OPEN, IT IS NOT READY FOR START UP.
BEFORE YOU START INSTALLING
1. CALL OMNI TECHNOLOGIES, LLC. (608) 819-1980 TO SCHEDULE A
PROJECT REVIEW MEETING BEFORE INSTALLING ANY DEVICES.
2. IT IS BEST TO USE "DEEP" BACK BOXES WHEN INSTALLING MODULES
AND PULL STATIONS. THE DEEP BACK BOXES WILL PROVIDE MORE
ROOM FOR THE WIRES, AND IT WILL CUT DOWN ON GROUNDS AND
SHORTS.
3. WHEN INSTALLING DEVICES, TAPE THE "IN" SIDE OF THE WIRE WITH
BLACK ELECTRICAL TAPE TO AVOID CROSSING WIRE AND POLARITY.
4. WHEN USING SHIELDED CABLE, THE SHIELD MUST BE GROUNDED
ONLY AT THE FIRE ALARM CONTROL PANEL (DO NO GROUND
ANYWHERE ELSE). SHIELDS SHALL BE KEPT CONTINUOUS
THROUGHOUT THE CIRCUIT AND KEPT FREE FROM ANY REFERENCE
TO EARTH GROUND. SHIELDS MUST BE SPLICED THRU AND
INSULATED FROM EVERY BACK BOX. DO NO LAND SHIELD ON THE
DEVICE.
5. THE CUSTOM DEVICE MESSAGES FOR ANNUNCIATION ARE BASED ON
DRAWINGS PROVIDED BY ARCHITECT/ENGINEER. IF MESSAGES ARE
GOING TO CHANGE, END USER MUST SIGN OFF.
6. ALWAYS USE GROMMETS/BUSHINGS ON THE END OF CONDUIT
STUB-UPS, IN ELECTRICAL BOXES & CONNECTION TO PANELS, & ALL
POINTS WHERE WIRING EXITS CONDUIT, TO AVOID SCRAPING OF WIRE
COATING AND POTENTIAL GROUND FAULTS.
7. REVIEW CUT SHEETS FOR ALL DEVICES TO VERIFY CORRECT
INSTALLATION PROCEDURES ARE USED. EACH EXIT DEVICE HAS
INSTALLATION AND WIRING INSTRUCTIONS INCLUDED IN PACKAGING.
ALWAYS SAVE INSTRUCTION SHEETS, CUT SHEETS AND MANUALS
FOR THE OWNER.
8. FIRE WALL AND FLOOR PENETRATIONS MUST BE PATCHED WITH
APPROVED FIRE PATCH WHICH MAINTAINS THE PARTITIONS RATING.
BOTH SIDES OF THE PENETRATION MUST BE FIRESTOPPED.
9. PRIOR TO SCHEDULING START UP WITH OMNI TECHNOLOGIES, LLC.,
VERIFY THAT YOU PROJECT MEETS ALL THE CRITERIA OUTLINED IN
THE "CHECK LIST FOR START UP". A MINIMUM OF FIFTEEN BUSINESS
DAYS IS REQUIRED FOR SCHEDULING YOU START-UP.
POWER UP/DOWN SEQUENCE
CAUTION: ALWAYS REMOVE POWER (BATTERY/AC) AND WAIT AT LEAST 10
SECONDS TO ALLOW SUPPLY VOLTAGES TO DECAY BEFORE INSTALLING
OR REMOVING ANY MODULES, DETECTOR, OR WIRING. AUXILLARY
SUPPLIES MUST BE POWERED DOWN PRIOR TO THE MAIN SUPPLIES.
1. POWER UP SEQUENCE:
A. CONNECT AC POWER FIRST.
B. CONNECT THE BATTERY SECOND
1. POWER DOWN SEQUENCE:
A. DISCONNECT THE BATTERY FIRST
B. DISCONNECT AC POWER SECOND
NOTE: PLEASE REFER TO THE LOCAL JURISDICTION (AHJ) AND A
CURRENT COPY OF THE NATIONAL FIRE PROTECTION ASSOCIATION'S
NATIONAL ELECTRICAL CODE AND NATIONAL FIRE ALARM CODE FOR ANY
QUESTIONS YOU HAVE RELATED TO CODE COMPLIANCE. ALL
INFORMATION CONTAINED ON THIS SHEET IS GENERAL INFORMATION AND
SHOULD NOT BE USED AS A SOLE SOURCE FOR INSTALLATIONS. OMNI
TECHNOLOGIES, LLC. OR THEIR EMPLOYEES SHALL NOT BE RESPONSIBLE
FOR ANY MISINTERPRETATIONS OR LIABILITIES THAT MAY ARISE FROM
THE USE OF THIS DOCUMENT.
TRK
DEVICE SETTINGS:
· SEE FLOOR PLANS FOR DEVICE CANDELA SETTING
· SEE FLOOR PLANS FOR DEVICE SPEAKER TAP SETTING
· ALL SPEAKERS TO BE SET TO 70 VRMS OPERATING VOLTAGE
DRAWING INDEX:
FA000 FIRE ALARM TITLE PAGE
FA100A LOWER FLOOR AREA A FIRE ALARM PLAN
FA100B LOWER FLOOR AREA B FIRE ALARM PLAN
FA101A FIRST FLOOR AREA A FIRE ALARM PLAN
FA101B FIRST FLOOR AREA B FIRE ALARM PLAN
FA102A SECOND FLOOR AREA A FIRE ALARM PLAN
FA102B SECOND FLOOR AREA B FIRE ALARM PLAN
FA103A THIRD FLOOR AREA A FIRE ALARM PLAN
FA103B THIRD FLOOR AREA B FIRE ALARM PLAN
FA104A FOURTH FLOOR AREA A FIRE ALARM PLAN
FA104B FOURTH FLOOR AREA B FIRE ALARM PLAN
FA105A FIFTH FLOOR AREA A FIRE ALARM PLAN
FA105B FIFTH FLOOR AREA B FIRE ALARM PLAN
FA106A SIXTH FLOOR AREA A FIRE ALARM PLAN
FA106B SIXTH FLOOR AREA B FIRE ALARM PLAN
FA200 FIRE ALARM DETAILS PAGE 1 OF 2
FA201 FIRE ALARM DETAILS PAGE 2 OF 2
FA300 FIRE ALARM RISER DIAGRAM PAGE 1 OF 2
FA301 FIRE ALARM RISER DIAGRAM PAGE 2 OF 2
GENERAL NOTES:
· E.C. TO MOUNT ALL CEILING MOUNTED STROBES BELOW 30 FEET AFF.
100°
32°
INSTALLATION GUIDELINES
THE UL LISTED OPERATING TEMPERATURE RANGE FOR
ALL ADDRESSABLE DEVICES: MOST DEVICES ARE
RATED FOR 32°F (0°C) TO 100°F (38°C). IF A DEVICE IS
SHOWN IN AN AREA WHICH MAY EXPERIENCE EXTREME
COLD OR HEAT, CONTACT YOUR OMNI TECHNOLOGIES,
LLC. REPRESENTATIVE.
GENERAL RULE: IF IT IS UNCOMFORTABLE FOR YOU,
THE DEVICE WILL PROBABLY NOT OPERATE
CORRECTLY.
NEVER ALLOW ANY FIRE ALARM EQUIPMENT TO GET
WET. ONLY WEATHERPROOF NOTIFICATION
APPLIANCES (HORN/STROBES, STROBES, ETC.) MAY BE
INSTALLED OUTSIDE.
IF EQUIPMENT DOES GET WET, CONTACT YOUR OMNI
TECHNOLOGIES, LLC. PROJECT MANAGER.
DO NOT INSTALL ADDRESSABLE DEVICES UNTIL THEY
HAVE BEEN ADDRESSED.
DO NOT INSTALL NOTIFICATION DEVICES UNTIL THE
CANDELA AND DBA SWITCHES ARE SET.
SEE THE FIRE ALARM PLAN LAYOUT FOR ADDRESSES
AND SETTINGS.
DO NOT REMOVE THE ORANGE DUST COVERS FROM
SMOKE DETECTORS UNTIL ALL CONSTRUCTION HAS
BEEN COMPLETED.
DETECTORS THAT HAVE HAD THEIR DUST COVERS
REMOVED PRIOR TO THE FINAL CLEAN-UP OF ALL
TRADES SHALL BE CLEANED OR REPLACED,
ACCORDANCE WITH NFPA 72.
OMNI TECHNOLGIES, LLC CANNOT BE RESPONSIBLE
FOR PROBLEMS FOUND TO BE DUST AND DIRT
RELATED.
ALL INITIATING DEVICES (SMOKES, MANUAL PULLS,
HEATS, MODULES, ETC.),AND NOTIFICATION
APPLIANCES (HORNS, STROBES, ETC.) MUST BE
INSTALLED WITH BACKBOXES. THE EQUIPMENT SHOULD
NEVER BE SUPPORTED WITH THE CIRCUIT WIRES.
WALL MOUNTED NOTIFICATION DEVICES TO BE
MOUNTED AT 84" AFF TO BOTTOM. IF CEILING HEIGHT IS
TOO LOW TO ACCOMPLISH THIS, DEVICE MUST BE
MOUNTED WITHIN 6" OF CEILING.
PHOTOELECTRIC SMOKE DETECTORS ARE TO BE
MOUNTED AT LEAST 3'0" FROM ANY FLUORESCENT
LIGHT OR AIR DIFFUSER.
ELEVATOR HEATS FOR SHUNT TRIP TO BE MOUNTED
WITHIN 24" OF SPRINKLER HEAD.
IF DETECTORS ARE REQUIRED IN ELEVATOR PIT.
SMOKE DETECTORS FOR ELEVATOR RECALL SHALL BE
LOCATED WITHIN 21 FEET OF THE CENTERLINE OF EACH
ELEVATOR DOOR WITHIN THE ELEVATOR BANK UNDER
THE CONTROL OF THE DETECTOR.
SMOKE DETECTORS REQUIRED FOR DOOR RELEASE
SHALL BE LOCATED WITHIN 5 FEET OF THE DOOR BEING
CONTROLLED BY THE ASSOCIATED CONTROL RELAY
SMOKE DETECTORS THAT ARE LOCATED ON SLOPED
CEILINGS SHALL BE INSTALLED BETWEEN 4” AND 36” OF
THE PEAK.
WHERE REQUIRED, PULL STATIONS SHALL BE LOCATED
WITHIN 5 FEET OF AN INDIVIDUAL EXIT DOOR.
REMOTE TEST SWITCH TO BE MOUNTED IN A VISIBLE
AND ACCESSIBLE LOCATION
WALL MOUNTED STROBES SHALL BE INSTALLED IN A
MANNER WHICH AVOIDS OBSTRUCTION BY DOORS,
CABINETS, SHELVES ETC.
DO NOT USE DUCT SMOKE ON-BOARD RELAYS FOR AHU
SHUTDOWN UNLESS SPECIFICALLY INSTRUCTED TO DO
SO ON PROJECT DRAWINGS. IT IS PREFERRED TO USE A
SEPARATE RELAY FOR INTERFACING WITH HVAC
EQUIPMENT.
SMOKE AND HEAT DETECTORS SHALL BE INSTALLED
WITHIN 12 INCHES OR LESS OF THE HIGHEST PART OF
H
S S
S
H S
DS
WP
DEVICES THAT ARE INSTALLED IN AREAS WHERE
TEMPERATURE CAN DIFFER FROM THE AMBIENT ROOM
TEMPERATURE OF THE BUILDING SHALL HAVE
CONNECTING RACEWAYS PROPERLY SEALED TO PREVENT
CONDENSATION BUILD-UP.
CEILING.
COORDINATE WITH ELEVATOR CONTRACTOR TO VERIFY
WIRE LEGEND
FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)
FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)
(NAC POWER)
FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)
(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)
FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)
FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)
FF CAT6 (DATA/PHONE)
FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)
ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND
PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE
PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.
S
SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO BOTTOM
(EDWARDS: G4SVWF WITH GRSW-10)
S
HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-HRD WITH SIGA-SB4)
S
H
CONTROL RELAY - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CR)CR
SINGLE MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT1)CT1
DUAL MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT2)CT2
CONTROL MODULE WITH SYNC - DOUBLE GANG 21
2" DEEP (EDWARDS : SIGA-CC1S)CC1S
FLOW SWITCH - BY OTHERSFS
TAMPER SWITCH - BY OTHERSTS
*AREA OF WORK = 214,027 SQ. FEET
*OCCUPANCY TYPE - S-2
APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)
BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)
ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT
(FUNCTIONAL DEVICES : RIBU1C)RIB
50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50
FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP
(EDWARDS : EST4)FACP
DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL
SYMBOL LEGEND:
SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-OSD WITH SIGA-SB4)
SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO
BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)
DENOTES ELEVATOR RECALLER
RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX
PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP
DENOTES WEATHERPROOF DEVICEWP
B
B.3
C
D
E
F
STAIR 01
0S01
STAIR 04
0S04
STAIR 02
0S02
ELEVATOR 01
0E01
ELEVATOR
LOBBY
ELEVATOR
LOBBY
ELEVATOR 04
0E04 ELEVATOR 02
0E02
ELEVATOR
LOBBY
CITY STORAGE
LOWER LEVEL
PARKING
SA1
2W 110CD
V28
WP
SA1
2W 110CD
V28
WP
SA1
2W 110CD
V8
WP
SA1
2W 110CD
V8
WP
SA1
2W 110CD
V8-EOL
WP
SA1
2W 110CD
V28
WP
SA1
2W 110CD
V8
WP
SA1
2W 110CD
V8
WP
SA1
1W 15CD
V28-EOL
1W 75CD
SA1
2W 110CD
V28
WP
1-2-23S
ER
SA1
1W 15cd
V28
1-2-155 1-2-156
1-2-7S
1-2-3S
1-2-153 1-2-154
SA1
1W 15cd
V8
MATCHLINE MATCHLINE
S 1W A1A
CT2
FS
TS
CT2
FS
TS
(1)FB TO BPS#1
A
B
DATE:
O re go n
C en te r D r.
O re go n, W
I 5
Te l:
8.
9.
Fa x:
.8
.1 w w w .o m ni te ch no lo gi es llc .c om
ST
AT
E
ST
R
EE
T C
AM
PU
S G
AR
AG
E
N
O
RT
H
LA
KE
S
TR
EE
T M
AD
IS
O N
, W I 5
REVISIONS
DWG BY:
4-1-24 23-2176
AG
FI
RE
A
LA
RM
P
LA
N
JOB #
LOWER FLOOR AREA A FLOOR FIRE ALARM PLAN
1/8" = 1'-0"
OVERALL KEY PLAN
N.T.S.
LOWER
FLOOR
AREA A
FIRE
ALARM
PLAN
FA100A
WIRE LEGEND
FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)
FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)
(NAC POWER)
FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)
(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)
FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)
FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)
FF CAT6 (DATA/PHONE)
FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)
ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND
PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE
PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.
S
SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO BOTTOM
(EDWARDS: G4SVWF WITH GRSW-10)
S
HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-HRD WITH SIGA-SB4)
S
H
CONTROL RELAY - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CR)CR
SINGLE MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT1)CT1
DUAL MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT2)CT2
CONTROL MODULE WITH SYNC - DOUBLE GANG 21
2" DEEP (EDWARDS : SIGA-CC1S)CC1S
FLOW SWITCH - BY OTHERSFS
TAMPER SWITCH - BY OTHERSTS
*AREA OF WORK = 214,027 SQ. FEET
*OCCUPANCY TYPE - S-2
APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)
BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)
ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT
(FUNCTIONAL DEVICES : RIBU1C)RIB
50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50
FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP
(EDWARDS : EST4)FACP
DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL
SYMBOL LEGEND:
SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-OSD WITH SIGA-SB4)
SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO
BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)
DENOTES ELEVATOR RECALLER
RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX
PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP
1 2 2.6 2.93 4 5 6 7 8
F
G
H
I
J
K
ELEC. VAULT
ELEVATOR 03
0E03
STAIR 03
0S03
CITY STORAGE
ELEVATOR
LOBBY
LOWER LEVEL
PARKING
S 1W A1B
SA1
2W 110CD
V7
WP
SA1
2W 110CD
V7
WP
SA1
2W 110CD
V7
WP
SA1
2W 110CD
V7
WP
SA1
1W 30CD
V7
SA1
1W 30CD
V7
SA1
2W 110CD
V8
WP
SA1
1W 75CD
V28
SA1
2W 110CD
V7-EOL
WP
SA1
2W 110CD
V28
WP
1-2-22S
1-2-21 S SA1
1W 15CD
V7
ER
(1)FB TO BPS#1
(1)FB TO BPS#1
MATCHLINE
A
B
DATE:
O re go n
C en te r D r.
O re go n, W
I 5
Te l:
8.
9.
Fa x:
.8
.1 w w w .o m ni te ch no lo gi es llc .c om
ST
AT
E
ST
R
EE
T C
AM
PU
S G
AR
AG
E
N
O
RT
H
LA
KE
S
TR
EE
T M
AD
IS
O N
, W I 5
REVISIONS
DWG BY:
4-1-24 23-2176
AG
FI
RE
A
LA
RM
P
LA
N
JOB #
LOWER FLOOR AREA B FLOOR FIRE ALARM PLAN
1/8" = 1'-0"
OVERALL KEY PLAN
N.T.S.
LOWER
FLOOR
AREA B
FIRE
ALARM
PLAN
FA100B
WIRE LEGEND
FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)
FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)
(NAC POWER)
FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)
(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)
FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)
FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)
FF CAT6 (DATA/PHONE)
FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)
ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND
PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE
PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.
S
SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO BOTTOM
(EDWARDS: G4SVWF WITH GRSW-10)
S
HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-HRD WITH SIGA-SB4)
S
H
CONTROL RELAY - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CR)CR
SINGLE MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT1)CT1
DUAL MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT2)CT2
CONTROL MODULE WITH SYNC - DOUBLE GANG 21
2" DEEP (EDWARDS : SIGA-CC1S)CC1S
FLOW SWITCH - BY OTHERSFS
TAMPER SWITCH - BY OTHERSTS
*AREA OF WORK = 214,027 SQ. FEET
*OCCUPANCY TYPE - S-2
APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)
BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)
ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT
(FUNCTIONAL DEVICES : RIBU1C)RIB
50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50
FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP
(EDWARDS : EST4)FACP
DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL
SYMBOL LEGEND:
SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-OSD WITH SIGA-SB4)
SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO
BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)
DENOTES ELEVATOR RECALLER
RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX
PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP
B.3
FIRE COMMAND
CENTER
TRASH
PARCEL
STORAGE
MENS
WOMENS
HOUSING
MAINTENANCE
OFFICE
VESTIBULE
RECEPTION
TV LOUNGE
LOUNGE
STAIR 01
1S01
TLT
192BUS WAITING
TLT
BUS WAITING -
INTERIOR
EXIT PASSAGE
OFFICE
CAFE
GAME ROOM
RESIDENT
PARKING
ELEV 01
1E01
STAIR 04
1S04
ELEVATOR
LOBBY
ELEVATOR 04
1E04
ELEVATOR 02
1E02
ELEVATOR
LOBBY
STAIR 02
1S02
GENERATOR
MDF
CORRIDOR
BUS TERMINAL
SEATING
OFFICE
MAINTENANCE
HOUSING
STORAGE
118A
TLT
185A
ENCLAVE
ENCLAVE
ENCLAVE
ENCLAVE
OFFICE
OFFICE
OFFICE
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1D1
D1 D1
SA2
1W 110CD
V29
WP
SA2
1W 110CD
V29
WP
AP
S1
FA
CPAA501-2-138
1-2-137
1-2-136 1-2-135 A2 1-2-134
BP
S1
(1)FB TO BPS#1
MATCHLINE
NOT IN SCOPE
SEE THEORY MADISON FIRE ALARM DRAWINGS
CC1
CC1
CC1 A1B STAIRS 2
A1A STAIRS 3
A1
1-2-189 1-2-190 1-2-192
#1
#1
1-2-148
AA30
CC1S
CC1S
LOWER FL.
1ST FL.
A
B
DATE:
O re go n
C en te r D r.
O re go n, W
I 5
Te l:
8.
9.
Fa x:
.8
.1 w w w .o m ni te ch no lo gi es llc .c om
ST
AT
E
ST
R
EE
T C
AM
PU
S G
AR
AG
E
N
O
RT
H
LA
KE
S
TR
EE
T M
AD
IS
O N
, W I 5
REVISIONS
DWG BY:
4-1-24 23-2176
AG
FI
RE
A
LA
RM
P
LA
N
JOB #
FIRST FLOOR AREA A FLOOR FIRE ALARM PLAN
1/8" = 1'-0"
OVERALL KEY PLAN
N.T.S.
FIRST
FLOOR
AREA A
FIRE
ALARM
PLAN
FA101A
WIRE LEGEND
FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)
FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)
(NAC POWER)
FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)
(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)
FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)
FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)
FF CAT6 (DATA/PHONE)
FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)
ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND
PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE
PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.
S
SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO BOTTOM
(EDWARDS: G4SVWF WITH GRSW-10)
S
HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-HRD WITH SIGA-SB4)
S
H
CONTROL RELAY - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CR)CR
SINGLE MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT1)CT1
DUAL MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT2)CT2
CONTROL MODULE WITH SYNC - DOUBLE GANG 21
2" DEEP (EDWARDS : SIGA-CC1S)CC1S
FLOW SWITCH - BY OTHERSFS
TAMPER SWITCH - BY OTHERSTS
*AREA OF WORK = 214,027 SQ. FEET
*OCCUPANCY TYPE - S-2
APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)
BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)
ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT
(FUNCTIONAL DEVICES : RIBU1C)RIB
50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50
FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP
(EDWARDS : EST4)FACP
DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL
SYMBOL LEGEND:
SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-OSD WITH SIGA-SB4)
SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO
BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)
DENOTES ELEVATOR RECALLER
RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX
PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP
PUBLIC PARKING
4.95%
PARKING
BOOTH
1 2 2.6 2.93 4 5 6 7 8
FIRE PUMP &
WATER/
SPRINKLER
SERVICE
PLUMBING
EQUIPMENT
STUDY LOUNGE
LOUNGE
PUBLIC PARKING
180STAIR 05
1S05
ELEVATOR
LOBBY
ELEVATOR 03
1E03
STAIR 03
1S03
EXIT PASSAGE
CITY DEMARK
ROOM
CITY ELECTRICAL
ROOM
HOUSING
ELECTRICAL
ROOM
CITY OFFICE
TLT
181A
OFFICE
OFFICE
OFFICE
WORK ROOM
STUDY ROOM
STUDY ROOM
STUDY ROOM
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1 D1
SA2
1W 30CD
V1
SA2
1W 110CD
V1
WP
SA2
1W 15CD
V1
2SA2
1W 30CD
V1
SA2
1W 110CD
V1
WP
SA2
1W 110CD
V1
WP
SA2
1W
30CD
V1-EOL
SA2
1W 75CD
V29
SA2
1W 15CD
V29
1-2-20S
(1)FB TO APS#1
ER
SA2
1W 110CD
V29-EOL
WP
SA2
1W 110CD
V29
WP
MATCHLINE
SA2
1W 75CD
V29
A
B
DATE:
O re go n
C en te r D r.
O re go n, W
I 5
Te l:
8.
9.
Fa x:
.8
.1 w w w .o m ni te ch no lo gi es llc .c om
ST
AT
E
ST
R
EE
T C
AM
PU
S G
AR
AG
E
N
O
RT
H
LA
KE
S
TR
EE
T M
AD
IS
O N
, W I 5
REVISIONS
DWG BY:
4-1-24 23-2176
AG
FI
RE
A
LA
RM
P
LA
N
JOB #
FIRST FLOOR AREA B FLOOR FIRE ALARM PLAN
1/8" = 1'-0"
OVERALL KEY PLAN
N.T.S.
FIRST
FLOOR
AREA B
FIRE
ALARM
PLAN
FA101B
WIRE LEGEND
FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)
FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)
(NAC POWER)
FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)
(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)
FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)
FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)
FF CAT6 (DATA/PHONE)
FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)
ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND
PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE
PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.
S
SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO BOTTOM
(EDWARDS: G4SVWF WITH GRSW-10)
S
HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-HRD WITH SIGA-SB4)
S
H
CONTROL RELAY - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CR)CR
SINGLE MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT1)CT1
DUAL MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT2)CT2
CONTROL MODULE WITH SYNC - DOUBLE GANG 21
2" DEEP (EDWARDS : SIGA-CC1S)CC1S
FLOW SWITCH - BY OTHERSFS
TAMPER SWITCH - BY OTHERSTS
*AREA OF WORK = 214,027 SQ. FEET
*OCCUPANCY TYPE - S-2
APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)
BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)
ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT
(FUNCTIONAL DEVICES : RIBU1C)RIB
50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50
FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP
(EDWARDS : EST4)FACP
DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL
SYMBOL LEGEND:
SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-OSD WITH SIGA-SB4)
SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO
BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)
DENOTES ELEVATOR RECALLER
RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX
PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP
B.3
C
D
E
F
STAIR 02
2S02
STAIR 01
2S01
ELEVATOR 01
2E01
PUBLIC PARKING
ELEVATOR 04
2E04
STAIR 04
2S04 ELEVATOR
LOBBY
ELEVATOR 02
2E02
ELEVATOR
LOBBY
MEP
L-G1
NL1-1
L-G1
NL1-1
L-G2
NL1-1
L-G2
NL1-1
L-G3
NL1-1
L-G3
NL1-1
L-C
NL1-1
L-C
NL1-1
L-C
NL1-1
L-F
NL1-1
L-F
NL1-1
L-F
NL1-1
L-F
NL1-1
L-F
NL1-1
L-F
NL1-1
L-F
NL1-1
L-F
NL1-1
L-F
NL1-1
SA3
1W 15CD
V30-EOL
SA3
1W 110CD
V30
WP
SA3
1W 110CD
V30
WP
SA3
1W 110CD
V30
WP SA3
1W 110CD
V30
WP
SA3
1W 110CD
V30
WP SA3
1W 110CD
V2-EOL
WP
1-2-55 S
1-2-166CT2 1-2-165
1-2-164CT2 1-2-163
ER
FS
TS
FS
TS
S9 1W 15cd
V30-EOL
SA3
1W 15cd
V30
WP
MATCHLINE
1-2-193 1-2-194
1-2-50S
1-2-51S
1-2-175
1-2-176CT2
FS
TS
CT2
FS
TS
OPEN TO BELOW
(1)FB TO BPS#2
SA3
1W 15cd
V30
A
B
DATE:
O re go n
C en te r D r.
O re go n, W
I 5
Te l:
8.
9.
Fa x:
.8
.1 w w w .o m ni te ch no lo gi es llc .c om
ST
AT
E
ST
R
EE
T C
AM
PU
S G
AR
AG
E
N
O
RT
H
LA
KE
S
TR
EE
T M
AD
IS
O N
, W I 5
REVISIONS
DWG BY:
4-1-24 23-2176
AG
FI
RE
A
LA
RM
P
LA
N
JOB #
SECOND FLOOR AREA A FLOOR FIRE ALARM PLAN
1/8" = 1'-0"
OVERALL KEY PLAN
N.T.S.
SECOND
FLOOR
AREA A
FIRE
ALARM
PLAN
FA102A
WIRE LEGEND
FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)
FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)
(NAC POWER)
FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)
(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)
FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)
FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)
FF CAT6 (DATA/PHONE)
FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)
ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND
PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE
PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.
S
SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO BOTTOM
(EDWARDS: G4SVWF WITH GRSW-10)
S
HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-HRD WITH SIGA-SB4)
S
H
CONTROL RELAY - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CR)CR
SINGLE MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT1)CT1
DUAL MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT2)CT2
CONTROL MODULE WITH SYNC - DOUBLE GANG 21
2" DEEP (EDWARDS : SIGA-CC1S)CC1S
FLOW SWITCH - BY OTHERSFS
TAMPER SWITCH - BY OTHERSTS
*AREA OF WORK = 214,027 SQ. FEET
*OCCUPANCY TYPE - S-2
APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)
BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)
ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT
(FUNCTIONAL DEVICES : RIBU1C)RIB
50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50
FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP
(EDWARDS : EST4)FACP
DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL
SYMBOL LEGEND:
SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-OSD WITH SIGA-SB4)
SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO
BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)
DENOTES ELEVATOR RECALLER
RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX
PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP
G
H
I
J
K
ELEVATOR
LOBBY
ELEVATOR 03
2E03
STAIR 03
2S03
MEP
STAIR 05
2S05
HA11-EM(8')
EMH1-7 HA11-EM(4')
EMH1-7
HA11-EM(4')
EMH1-7
HA12-EM
EMH1-6
HA12-EM
EMH1-6
L-B
NL1-1
L-B
NL1-1
L-B
NL1-1
L-F
NL1-1
L-F
NL1-1
L-F
NL1-1
L-F
NL1-1
L-F
NL1-1
L-F
NL1-1
SA3
1W 110CD
V30
WP SA3
1W 110CD
V2-EOL
WP
SA3
1W 110CD
V2
WP
SA3
1W 110CD
V2
WP
SA3
1W 110CD
V2
WP
SA3
1W 110CD
V2
WP
SA3
1W 15CD
V2
1-2-56 S
(1)FB TO APS#2
ER
SA3
2W 75cd
V2
1-2-11S
1-2-171 1-2-172
MATCHLINE
CT2
FS
TS
(1)FB TO BPS#2
A
B
DATE:
O re go n
C en te r D r.
O re go n, W
I 5
Te l:
8.
9.
Fa x:
.8
.1 w w w .o m ni te ch no lo gi es llc .c om
ST
AT
E
ST
R
EE
T C
AM
PU
S G
AR
AG
E
N
O
RT
H
LA
KE
S
TR
EE
T M
AD
IS
O N
, W I 5
REVISIONS
DWG BY:
4-1-24 23-2176
AG
FI
RE
A
LA
RM
P
LA
N
JOB #
SECOND FLOOR AREA B FLOOR FIRE ALARM PLAN
1/8" = 1'-0"
OVERALL KEY PLAN
N.T.S.
SECOND
FLOOR
AREA B
FIRE
ALARM
PLAN
FA102B
WIRE LEGEND
FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)
FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)
(NAC POWER)
FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)
(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)
FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)
FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)
FF CAT6 (DATA/PHONE)
FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)
ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND
PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE
PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.
S
SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO BOTTOM
(EDWARDS: G4SVWF WITH GRSW-10)
S
HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-HRD WITH SIGA-SB4)
S
H
CONTROL RELAY - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CR)CR
SINGLE MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT1)CT1
DUAL MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT2)CT2
CONTROL MODULE WITH SYNC - DOUBLE GANG 21
2" DEEP (EDWARDS : SIGA-CC1S)CC1S
FLOW SWITCH - BY OTHERSFS
TAMPER SWITCH - BY OTHERSTS
*AREA OF WORK = 214,027 SQ. FEET
*OCCUPANCY TYPE - S-2
APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)
BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)
ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT
(FUNCTIONAL DEVICES : RIBU1C)RIB
50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50
FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP
(EDWARDS : EST4)FACP
DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL
SYMBOL LEGEND:
SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-OSD WITH SIGA-SB4)
SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO
BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)
DENOTES ELEVATOR RECALLER
RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX
PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP
B.3
C
D
E
F
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1HA11-EM(4')
EML1-1
HA16-EM
EML1-1
HA11-EM(8')
EML1-1
HA11-EM(8')
EML1-1
L-S
L-T
NLP5-1
L-T
NLP5-1
L-T
NLP5-1
L-T
NLP5-1
L-T
NLP5-1
L-S
L-S
NLP5-1
EML1-1
EML1-1EML1-1
NLP5-1
EML1-1
NLP5-1
SA4
1W 110CD
V3
WP
SA4
1W 110CD
V3
WP
SA4
1W 110CD
V3
WP
SA4
1W 110CD
V3-EOL
WP
SA4
1W 110CD
V31 - EOL
WP
SA4
1W 110CD
V3
WP
SA4
1W 15CD
V3
1-2-53 S
1-2-162CT2 1-2-161
1-2-133 1-2-132 1-2-131 1-2-130
A3
A4
CC1S1-2-129
AP
S1
1-2-2S
AA30
ER
FS
TS
1-2-139 1-2-140
1-2-4S
SA4
1W 15cd
V3
N O
T
IN
S C
O
PE
N
T
IN
S
C
SE
E
TH
EO
R Y
M
AD
IS
O
N F
IR
E
AL
AR
M D
R
AW
IN
G
S
MATCHLINE
S 1W A1A
CT2
FS
TS
#2
(1)FB TO BPS#2
BP
S1
#2
CC1S1-2-177
2ND FL.
3RD FL.
AA30
A
B
DATE:
O re go n
C en te r D r.
O re go n, W
I 5
Te l:
8.
9.
Fa x:
.8
.1 w w w .o m ni te ch no lo gi es llc .c om
ST
AT
E
ST
R
EE
T C
AM
PU
S G
AR
AG
E
N
O
RT
H
LA
KE
S
TR
EE
T M
AD
IS
O N
, W I 5
REVISIONS
DWG BY:
4-1-24 23-2176
AG
FI
RE
A
LA
RM
P
LA
N
JOB #
THIRD FLOOR AREA A FLOOR FIRE ALARM PLAN
1/8" = 1'-0"
OVERALL KEY PLAN
N.T.S.
THIRD
FLOOR
AREA A
FIRE
ALARM
PLAN
FA103A
WIRE LEGEND
FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)
FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)
(NAC POWER)
FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)
(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)
FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)
FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)
FF CAT6 (DATA/PHONE)
FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)
ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND
PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE
PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.
S
SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO BOTTOM
(EDWARDS: G4SVWF WITH GRSW-10)
S
HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-HRD WITH SIGA-SB4)
S
H
CONTROL RELAY - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CR)CR
SINGLE MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT1)CT1
DUAL MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT2)CT2
CONTROL MODULE WITH SYNC - DOUBLE GANG 21
2" DEEP (EDWARDS : SIGA-CC1S)CC1S
FLOW SWITCH - BY OTHERSFS
TAMPER SWITCH - BY OTHERSTS
*AREA OF WORK = 214,027 SQ. FEET
*OCCUPANCY TYPE - S-2
APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)
BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)
ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT
(FUNCTIONAL DEVICES : RIBU1C)RIB
50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50
FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP
(EDWARDS : EST4)FACP
DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL
SYMBOL LEGEND:
SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-OSD WITH SIGA-SB4)
SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO
BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)
DENOTES ELEVATOR RECALLER
RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX
PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP
G
H
I
J
K
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
C1-EM
EML1-1
HA11-EM(4')
EML1-1
C1-EM
EML1-1
HA12-EM
EMH1-6
HA12-EM
EMH1-6
L-T
NLP5-1
L-T
NLP5-1
L-T
NLP5-1
L-T
NLP5-1
L-S
L-S
EML1-1
NLP5-1
EML1-1EML1-1
NLP5-1
EML1-1
EML1-1
SA4
1W 110CD
V31 - EOL
WP
SA4
1W 110CD
V31
WP
SA4
1W 110CD
V31
WPSA4
1W 110CD
V31
WP
SA4
1W 110CD
V31
WP
SA4
1W 110CD
V3
WP
SA4
1W 15CD
V31
1-2-54 S
ER
N O
T
IN
S C
TH
EO
R
Y M
AD
IS
O N
F
IR
E
AL
AR
M
D R
AW
IN
G S
N O
T
IN
S C
MATCHLINE
1W A1B
(1)FB TO BPS#2
(1)FB TO BPS#2
A
B
DATE:
O re go n
C en te r D r.
O re go n, W
I 5
Te l:
8.
9.
Fa x:
.8
.1 w w w .o m ni te ch no lo gi es llc .c om
ST
AT
E
ST
R
EE
T C
AM
PU
S G
AR
AG
E
N
O
RT
H
LA
KE
S
TR
EE
T M
AD
IS
O N
, W I 5
REVISIONS
DWG BY:
4-1-24 23-2176
AG
FI
RE
A
LA
RM
P
LA
N
JOB #
THIRD FLOOR AREA B FLOOR FIRE ALARM PLAN
1/8" = 1'-0"
OVERALL KEY PLAN
N.T.S.
THIRD
FLOOR
AREA B
FIRE
ALARM
PLAN
FA103B
WIRE LEGEND
FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)
FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)
(NAC POWER)
FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)
(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)
FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)
FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)
FF CAT6 (DATA/PHONE)
FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)
ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND
PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE
PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.
S
SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO BOTTOM
(EDWARDS: G4SVWF WITH GRSW-10)
S
HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-HRD WITH SIGA-SB4)
S
H
CONTROL RELAY - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CR)CR
SINGLE MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT1)CT1
DUAL MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT2)CT2
CONTROL MODULE WITH SYNC - DOUBLE GANG 21
2" DEEP (EDWARDS : SIGA-CC1S)CC1S
FLOW SWITCH - BY OTHERSFS
TAMPER SWITCH - BY OTHERSTS
*AREA OF WORK = 214,027 SQ. FEET
*OCCUPANCY TYPE - S-2
APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)
BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)
ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT
(FUNCTIONAL DEVICES : RIBU1C)RIB
50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50
FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP
(EDWARDS : EST4)FACP
DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL
SYMBOL LEGEND:
SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-OSD WITH SIGA-SB4)
SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO
BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)
DENOTES ELEVATOR RECALLER
RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX
PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP
B.3
C
D
E
F
PUBLIC PARKING
STAIR 04
4S04
ELEVATOR
LOBBY
ELEVATOR 04
4E04
STAIR 02
4S02
ELEVATOR 02
4E02
ELEVATOR
LOBBY
STAIR 01
4S01
ELEVATOR 01
4E01
ELEVATOR
LOBBY
UNIT TH6
302U
UNIT TH1A
304U
UNIT TH1B
306U
UNIT TH2
308U
UNIT TH1B
310U
STORAGE
IDF / MDF
HA11-EM(8')
EMH1-7
HA11-EM(8')
EMH1-7
HA11-EM(8')
EMH1-7
HA11-EM(8')
EMH1-7
HA11-EM(4')
EMH1-7
HA11-EM(8')
EMH1-7
HA11-EM(8')
EMH1-7
HA11-EM(8')
EMH1-7
HA11-EM(8')
EMH1-7
HA11-EM(8')
EMH1-7
HA11-EM(8')
EMH1-7
EMH1-7
SA5
1W 110CD
V5
WP
SA5
1W 110CD
V5
WP
SA5
1W 110CD
V5
WP
SA5
1W 110CD
V5-EOL
WP
S13
1W 110CD
V4 - EOL
WP
SA5
1W 110CD
V5
WP
SA5
1W 15CD
V5
1-2-41 S
1-2-160CT2 1-2-159
ER
FS
TS
1-2-52S
1-2-173 1-2-174
SA5
1W 15cd
V5
N O
T
IN
S C
T
IN
S
C
TH
EO
R Y
M
AD
IS
O
N F
IR
E
AL
AR
M D
R
AW
IN
G
S
MATCHLINE
CT2
FS
TS
(1)FB TO APS#3
A
B
DATE:
O re go n
C en te r D r.
O re go n, W
I 5
Te l:
8.
9.
Fa x:
.8
.1 w w w .o m ni te ch no lo gi es llc .c om
ST
AT
E
ST
R
EE
T C
AM
PU
S G
AR
AG
E
N
O
RT
H
LA
KE
S
TR
EE
T M
AD
IS
O N
, W I 5
REVISIONS
DWG BY:
4-1-24 23-2176
AG
FI
RE
A
LA
RM
P
LA
N
JOB #
FOURTH FLOOR AREA A FLOOR FIRE ALARM PLAN
1/8" = 1'-0"
OVERALL KEY PLAN
N.T.S.
FOURTH
FLOOR
AREA A
FIRE
ALARM
PLAN
FA104A
WIRE LEGEND
FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)
FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)
(NAC POWER)
FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)
(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)
FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)
FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)
FF CAT6 (DATA/PHONE)
FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)
ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND
PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE
PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.
S
SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO BOTTOM
(EDWARDS: G4SVWF WITH GRSW-10)
S
HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-HRD WITH SIGA-SB4)
S
H
CONTROL RELAY - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CR)CR
SINGLE MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT1)CT1
DUAL MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT2)CT2
CONTROL MODULE WITH SYNC - DOUBLE GANG 21
2" DEEP (EDWARDS : SIGA-CC1S)CC1S
FLOW SWITCH - BY OTHERSFS
TAMPER SWITCH - BY OTHERSTS
*AREA OF WORK = 214,027 SQ. FEET
*OCCUPANCY TYPE - S-2
APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)
BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)
ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT
(FUNCTIONAL DEVICES : RIBU1C)RIB
50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50
FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP
(EDWARDS : EST4)FACP
DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL
SYMBOL LEGEND:
SMOKE DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-OSD WITH SIGA-SB4)
SPEAKER / STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO
BOTTOM (EDWARDS: GCSVWF WITH GRSW-10)
DENOTES ELEVATOR RECALLER
RE-ENTRANT WEATHERPROOF SPEAKER / STROBE WALL MOUNTED - BACK BOX
PROVIDED (EDWARDS : 757-7A-RS70 WITH 757A-WB BACK BOX & LKC-1 LENS KIT )WP
G
H
I
J
K
ELEVATOR
LOBBY
ELEVATOR 03
4E03
STAIR 03
4S03
UNIT TH1B
310U
UNIT TH3
312U
UNIT TH5
316U
UNIT TH4
314U
STAIR 05
4S05
MECH
CLOSET
HA12-EM
EMH1-6
HA12-EM
EMH1-6
HA11-EM(4')
EMH1-7
HA11-EM(4')
EMH1-7
HA11-EM(4')
EMH1-7
EMH1-7
HA11-EM(8')
EMH1-7
HA11-EM(8')
EMH1-7
HA11-EM(8')
EMH1-7
HA11-EM(4')
EMH1-7
HA11-EM(4')
EMH1-7
HA11-EM(8')
EMH1-7
EMH1-7
EMH1-7
EMH1-7
EMH1-7
EMH1-7
WP
SA5
1W 110CD
V4
WP
SA5
1W 110CD
V4
WP
SA5
1W 110CD
V4
WP
SA5
1W 110CD
V4
WP
A5 V5
WP
SA5
1W 15CD
V4
1-2-42 S
ER
N O
T
IN
S C
TH
EO
R
Y M
AD
IS
O N
F
IR
E
AL
AR
M
D R
AW
IN
G S
N O
T
IN
S C
TH
EO
R
Y M
AD
IS
O N
F
IR
E
AL
AR
M
D R
AW
IN
G S
MATCHLINE
(1)FB TO APS#3
A
B
DATE:
O re go n
C en te r D r.
O re go n, W
I 5
Te l:
8.
9.
Fa x:
.8
.1 w w w .o m ni te ch no lo gi es llc .c om
ST
AT
E
ST
R
EE
T C
AM
PU
S G
AR
AG
E
N
O
RT
H
LA
KE
S
TR
EE
T M
AD
IS
O N
, W I 5
REVISIONS
DWG BY:
4-1-24 23-2176
AG
FI
RE
A
LA
RM
P
LA
N
JOB #
FOURTH FLOOR AREA B FLOOR FIRE ALARM PLAN
1/8" = 1'-0"
OVERALL KEY PLAN
N.T.S.
FOURTH
FLOOR
AREA B
FIRE
ALARM
PLAN
FA104B
WIRE LEGEND
FA 2C-18AWG THHN OR TW/UN (BELDEN - 5320UL OR EQUIVALENT) (INITIATION CIRCUIT)
FB 2C-12AWG THHN OR TW/UN STRANDED (BELDEN - 5020UL OR EQUIVALENT)
(NAC POWER)
FC 2C-18AWG TW/UN (BELDEN - 5320UJ OR EQUIVALENT)
(NETWORK COMMUNICATIONS) (SIX TWISTS PER FT. MIN.)
FD 2C-14AWG THHN OR TW/UN (BELDEN - 5120UL OR EQUIVALENT) (AUX. POWER)
FE 2C-16AWG TW/UN (BELDEN - 5220UL OR EQUIVALENT) (SPEAKER CIRCUIT)
FF CAT6 (DATA/PHONE)
FK 2C-18AWG TW/SH (BELDEN - 5320FJ OR EQUIVALENT) (AUDIO RISER)
ELECTRICAL CONTRACTOR TO CONFIRM BUILDING AND INSTALLATION CONDITIONS AND
PROVIDE THE PROPERLY RATED CABLE FOR THE INSTALLATION. CABLE TYPES ARE
PROVIDED AS A BASIS OF DESIGN ONLY AND EQUIVALENTS MAY BE USED.
S
SPEAKER/ STROBE WALL MOUNTED - 4" SQUARE 21
8" DEEP, 84" AFF TO BOTTOM
(EDWARDS: G4SVWF WITH GRSW-10)
S
HEAT DETECTOR CEILING MOUNTED - 1 GANG OR 4" SQUARE
(EDWARDS : SIGA-HRD WITH SIGA-SB4)
S
H
CONTROL RELAY - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CR)CR
SINGLE MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT1)CT1
DUAL MONITOR MODULE - SINGLE GANG 21
2" DEEP (EDWARDS : SIGA-CT2)CT2
CONTROL MODULE WITH SYNC - DOUBLE GANG 21
2" DEEP (EDWARDS : SIGA-CC1S)CC1S
FLOW SWITCH - BY OTHERSFS
TAMPER SWITCH - BY OTHERSTS
*AREA OF WORK = 214,027 SQ. FEET
*OCCUPANCY TYPE - S-2
APS10 AUXILIARY POWER SUPPLY - 72" AFF TO TOP (EDWARDS : APS10A)
BPS10 BOOSTER POWER SUPPLY - 72" AFF TO TOP (EDWARDS : BPS10A)
ENCLOSED PILOT RELAY 10 AMP SPDT - KNOCKOUT MOUNT
(FUNCTIONAL DEVICES : RIBU1C)RIB
50 WATT AUDIO AMPLIFIER - MOUNTS IN AUXILIARY POWER SUPPLYAA50
FIRE ALARM CONTROL PANEL - BACK BOX PROVIDED, 72" AFF TO TOP
(EDWARDS : EST4)FACP
DENOTES END OF LINE (LAST DEVICE ON CIRCUIT)EOL
SYMBOL LEGEND:
SMOKE DETECTOR…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .