About this file

The document is an Addendum #1 for the Clay County Courthouse Renovation project, involving updated architectural and engineering plans for the Clay County Board of County Commissioners. The renovation will take place at 825 N. Orange Avenue in Green Cove Springs, Florida, with the addendum updating multiple drawing sheets including floor plans, life safety plans, interior finish schedules, power and telecommunications plans, and demolition details. The plans cover renovations to the first and second floors of the courthouse, including security screening areas, offices, corridors, judges' chambers, and various administrative spaces.

The project involves comprehensive interior modifications, including new flooring, wall finishes, security checkpoints, and technological infrastructure updates. The documents provide detailed specifications for materials, including vinyl tile, carpet, paint colors, ceramic tiles, and base materials. The renovation appears to be focused on modernizing the courthouse's functionality and security, with specific attention to creating a new security screening system, updating telecommunications infrastructure, and improving spatial configurations for various courthouse departments. The plans indicate a thorough approach to renovation, addressing both aesthetic and functional improvements while maintaining the building's historical character.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL NOTES - PARTITIONS

A. ALL DIMENSIONS ARE TO FACE OF STUD OR FACE OF CMU UNLESS OTHERWISE NOTED

B. ALL INTERIOR STUD PARTITIONS ARE TYPE S4B1 UNLESS OTHERWISE NOTED.

C. ALL INTERIOR CMU PARTITIONS ARE TYPE M08 UNLESS OTHERWISE NOTED.

D. ALL GYPSUM BOARD USED IN WET AREAS OR EXPOSED TO MOISTURE SHALL BE MOISTURE-RESISTANT GYPSUM

BOARD.

E. ALL GYPSUM BOARD IS TO BE 5/8" THICK UNLESS OTHERWISE NOTED.

F. AT ALL UL RATED ASSEMBLIES, ALL COMPONENTS USED MUST COMPLY STRICTLY WITH THE REQUIREMENTS OF THE

TESTED ASSEMBLY INCLUDING MANUFACTURER'S PROPRIETARY PRODUCTS. WHERE A CONFLICT OCCURS WITH THE

MATERIALS CALLED OUT ON THE PARTITION LEGEND, THE UL DESIGN SHALL GOVERN.

G. AT ALL FIRE RATED PARTITIONS, GYPSUM BOARD PANELS TO BE FIRE-CODE RATED PANELS. REFER TO THE UL DESIGN

FOR THE PRECISE TYPE OF GYPSUM BOARD.

H. ALL FIRE RATED PARTITIONS EXTEND TO STRUCTURE ABOVE AND SHALL BE FIRE STOPPED WHERE MEETING THE DECK WITH APPROVED UL ASSEMBLY. CUT GYPSUM BOARD WITHIN 1/2" OF DECK CORRUGATIONS OR OTHER

IRREGULARITIES.

I. ALL PENETRATIONS THROUGH FIRE-RATED PARTITIONS SHALL BE FIRESTOPPED WITH APPROVED UL ASSEMBLY.

J. ALL FIRE-RATED PARTITIONS SHALL RECEIVE A PAINTED RED STENCIL BOTH SIDES STATING" X-HR RATED PARTITION -

SEAL ALL PENETRATIONS" AT A SPACING OF NO MORE THAN 20 FEET ON CENTER.

K. ALL PARTITIONS EXTENDING TO THE DECK THAT ARE NOT FIRE RATED SHALL BE CONSIDERED "ACOUSTICAL

PARTITIONS" AND SHALL RECEIVE ACOUSTICAL SEALANT AT ALL PENETRATIONS AND WHERE THE WALL MEETS THE FLOOR AND DECK (BOTH SIDES). CUT GYPSUM BOARD WITHIN 1/2" OF DECK CORRUGATIONS OR OTHER

IRREGULARITIES AND APPLY ACOUSTICAL SEALANT.

L. BOTTOM OF WALL: CUT GYPSUM BOARD MIN 1/4" MAX 1/2" ABOVE FLOOR. APPLY ACOUSTICAL SEALANT BOTH SIDES AT ALL WALLS. FIRESTOP WITH AN APPROVED UL ASSEMBLY WHERE GAP EXCEEDS 1/2" AT FIRE RATED PARTITIONS.

M. GAUGE OF STEEL STUDS IS TO BE AS REQURIED TO MEET DEFLECTION CRITERIA INDICATED IN SPECS FOR HEIGHT OF

WALL AND ACTUAL JOB CONDITIONS.

N. STAGGER LOCATIONS OF ELECTRICAL JUNCTION BOXES AND OTHER DEVICES A MINIMUM OF 24" AT ACOUSTICAL AND

FIRE RATED PARTITIONS.

O. MAINTAIN CONTINUITY OF SMOKE PARTITIONS, FIRE BARRIERS, AND FIRE PARTITIONS. PER FBC 419.3.9.5, ALL RATED SMOKE BARRIERS, FIRE BARRIERS, AND FIRE PARTITIONS SHALL BE CONSTRUCTED BEFORE THE CONSTRUCTION OF INTERVENING LOWER-PRIORITY (NON-RATED PARTITIONS. LAYERS OF GYPSUM BOARD AT THE RATED ASSEMBLIES

SHALL BE CONTINUOUS AND UNINTERRUPTED.

DIM TO SUBSTRATE

7' - 0"

CLEAR DIM TO FINISH

7' - 0"

DIMENSION TYPES:

ACOUSTIC SEALANT -

BOTH SIDES

3" SOUND ATTEN. BATTS

WHERE SCHED

CEILING - SEE RCP FOR

TYPE & HT

ACOUSTIC SEALANT

5/8" GWB ON MTL STUDS

@ 16" O.C.

B A

S E

CEILING - SEE RCP FOR

TYPE & HT

BRACE TOP OF WALL @ 48"

O.C. W/ DIAGONAL KICKERS

OR EXTEND STUDS TO BTM

OF ROOF TRUSS BTM

CHORD

CEILING - SEE RCP FOR

TYPE & HT

BRACE TOP OF WALL @ 48"

O.C. W/ DIAGONAL KICKERS

OR EXTEND STUDS TO BTM

OF ROOF TRUSS BTM

CHORD

5/8" GWB ON 7/8" MTL

FURRING CHANNELS @

24" O.C.

CEILING - SEE RCP FOR

TYPE & HT

ACOUSTICAL SEALANT

F.T. 2X TOP & BTM

STUD FRAMING

WALL MODIFIERS (APPLIED OVER OTHER WALL TYPES)

5/8" GWB ON 2" Z-FURRING

CHANNELS @ 24" O.C.

CEILING - SEE RCP FOR

TYPE & HT

CONT 2" THK FOIL-FACED

RIGID INSULATION

3" SOUND ATTEN. BATTS

WHERE SCHED WHERE

SCHEDULED

ACOUSTIC SEALANT -

BOTH SIDES

ACOUSTIC SEALANT

F.T. 2X TOP & BTM

ACOUSTICAL SEALANT

CONTINUE INSULATION TO

UNDERSIDE OF

STRUCTURE

CEILING - SEE RCP FOR

TYPE & HT

ACOUSTICAL SEALANT

TOP TRACK

ADJACENT WALL

BRACE FRAMING TO

ADJACENT WALL

FIRE RATING

UL LISTING

COMMENT

PART'N TYPE STUD/BLOCK SIZE INSULATION STC FIRE RATING

B A

S E

P L

A N

H E

A D

SE_ _

NON-RATED

PARTIAL HEIGHT SINGLE SIDED PARTITION

2-1/2"

2-1/2"

3-5/8"

3-5/8"

SE2

SE2A

SE4

SE4A

NO

YES

NO

YES

FIRE RATING

UL LISTING

COMMENT

PART'N TYPE STUD/BLOCK SIZE INSULATION STC FIRE RATING

B A

S E

P L

A N

H E

A D

SA_ _

NON-RATED

PARTIAL HEIGHT PARTITION

3-5/8"

3-5/8"

6"

6"

SA4

SA4A

SA6

SA6A

NO

YES

NO

YES

FIRE RATING

UL LISTING

COMMENT

PART'N TYPE STUD/BLOCK SIZE INSULATION STC FIRE RATING

B A

S E

P L

A N

H E

A D

SB_ _

NON-RATED

FULL HEIGHT PARTITION

3-5/8"

3-5/8"

6"

6"

SB4

SB4A

SB6

SB6A

NO

YES

NO

YES

UL FIRE JOINT SYSTEM

FIRE RATING

UL LISTING

COMMENT

PART'N TYPE STUD/BLOCK SIZE INSULATION STC FIRE RATING

B A

S E

P L

A N

H E

A D

SC_ _

1 HR RATED PARTITION

UL U419

3-5/8"

3-5/8"

6"

6"

SC41

SC41A

SC61

SC61A

NO

YES

NO

YES

1-HR

1-HR

1-HR

1-HR

UL FIRE JOINT SYSTEM

FIRE RATING

UL LISTING

COMMENT

PART'N TYPE STUD/BLOCK SIZE INSULATION STC FIRE RATING

B A

S E

P L

A N

H E

A D

F_

NON-RATED

7/8" HAT CHANNELS

1-1/2" HAT CHANNELS

F1

F2

NO

NO

FIRE RATING

UL LISTING

COMMENT

PART'N TYPE STUD/BLOCK SIZE INSULATION STC FIRE RATING

B A

S E

P L

A N

H E

A D

F2Z

NON-RATED

2" Z-FURRING

FZ2

NO

FIRE RATING

UL LISTING

COMMENT

PART'N TYPE STUD/BLOCK SIZE INSULATION STC FIRE RATING

B A

S E

P L

A N

H E

A D

FS_ _

NON-RATED

1-5/8"

1-5/8"

2-1/2"

2-1/2"

FS2

FS2A

FS3

FS3A

NO

R13 THERMAL

NO

R13 THERMAL

FLOOR/ROOF

STRUCTURE ABOVE FLOOR/ROOF

STRUCTURE ABOVE

ACOUSTIC SEALANT

FIRE RATING

UL LISTING

COMMENT

PART'N TYPE STUD/BLOCK SIZE INSULATION STC FIRE RATING

B A

S E

P L

A N

H E

A D

SF_ _

NON-RATED

FULL HEIGHT SINGLE SIDED PARTITION

2-1/2"

2-1/2"

3-5/8"

3-5/8"

SF2

SF2A

SF4

SF4A

NO

YES

NO

YES

THERMAL BATT

INSULATION - SEE

SCHEDULE

EXTEND INSUL TO DECK

ABOVE WHERE OCCURS.

FIRE RATING

UL LISTING

COMMENT

PART'N TYPE STUD/BLOCK SIZE INSULATION STC FIRE RATING

B A

S E

P L

A N

H E

A D

SD_ _

2 HR RATED PARTITION

UL U419

3-5/8"

3-5/8"

6"

6"

SD42

SD42A

SD62

SD62A

NO

YES

NO

YES

2-HR

2-HR

2-HR

2-HR

UL FIRE JOINT SYSTEM

UL FIRE JOINT SYSTEM

FLOOR/ROOF

STRUCTURE ABOVE

6"6"

6"6" 6"

CEILING - SEE RCP FOR

TYPE & HT

3" SOUND ATTEN. BATTS

WHERE SCHED

CEILING - SEE RCP FOR

TYPE & HT

3" SOUND ATTEN. BATTS

WHERE SCHED

CEILING - SEE RCP FOR

TYPE & HT

5/8" GWB ON MTL STUDS

@ 16" O.C.

5/8" GWB ON MTL STUDS

@ 16" O.C.

2 LAYERS 5/8" GWB ON

MTL STUDS @ 16" O.C.

3" SOUND ATTEN. BATTS

WHERE SCHED

5/8" GWB ON MTL STUDS

@ 16" O.C.

3" SOUND ATTEN. BATTS

WHERE SCHED

5/8" GWB ON MTL STUDS

@ 16" O.C.

ADJACENT WALL ADJACENT WALL

5/8" GWB ON MTL STUDS

@ 16" O.C.

UL FIRE JOINT

SYSTEM

5/8" GWB - SEE TABLE

BELOW FOR QTY OF

LAYERS

1-1/2" SOUND ATTEN.

BLANKET

UL FIRE JOINT SYSTEM

UNDERSIDE OF STRUCTURE

SHAFT

1" THK GYPSUM LINER PANEL

CH MTL STUDS @ 24"

O.C. - SEE TABLE BELOW

FOR THKNS

FLOOR SLAB

ROOM

SIDE

FIRE RATING

UL LISTING

COMMENT

PART'N TYPE STUD/BLOCK SIZE INSULATION STC FIRE RATING

B A

S E

P L

A N

H E

A D

SH_ _

1-HR RATED OR 2-HR RATED

UL U415

TYPICAL SHAFT WALL

2-1/2"

2-1/2"

4"

4"

SH21

SH22

SH41

SH42

YES

YES

YES

YES

1-HR

2-HR

1-HR

2-HR

FIRE RATING

UL LISTING

COMMENT

PART'N TYPE STUD/BLOCK SIZE INSULATION STC FIRE RATING

B A

S E

P L

A N

H E

A D

SG_ _

3 HR RATED PARTITION

UL U419

3-5/8"

3-5/8"

6"

6"

SG43

SG43A

SG63

SG63A

NO

YES

NO

YES

3-HR

3-HR

3-HR

3-HR

UL FIRE JOINT SYSTEM

UL FIRE JOINT SYSTEM

FLOOR/ROOF

STRUCTURE ABOVE

3" SOUND ATTEN. BATTS

WHERE SCHED

CEILING - SEE RCP FOR

TYPE & HT

3 LAYERS 5/8" GWB ON

MTL STUDS @ 16" O.C.

3" @ 2 1/2" STUD

2" @ 1 5/8" STUD

CUT SOLID BLOCK AS REQ'D

SEE STRUCTURAL FOR

FOOTING OR THICKENED

SLAB

CMU - GROUT &

REINFORCE AS INDICATED

ON STRUCTURAL

CEILING - SEE RCP

FOR TYPE & HT

FIRE RATING

UL LISTING

COMMENT

PART'N TYPE STUD/BLOCK SIZE INSULATION STC FIRE RATING

B A

S E

P L

A N

H E

A D

M_

NON-RATED

SEE GENERAL NOTES ABOVE REGARDING TYPES OF CMU

5-5/8"

7-5/8"

11-5/8"

M6

M8

M12

MASONRY

DATE:

PROJECT NO.:PROJECT NO.:

THIS DRAWING IS AN INSTRUMENT OF SERVICE

AND IS THE PROPERTY OF DASHER HURST

ARCHITECTS, PA. IT SHALL NOT BE

REPRODUCED IN WHOLE OR IN PART WITHOUT

THE EXPRESS WRITTEN PERMISSION OF DASHER

HURST ARCHITECTS, PA.

DASHER HURST

1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8

A R C H I T E C T S

J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4

P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0

F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5

W. W. W. D A S H E R H U R S T . C O M

C O

U R

TH

O

U S E R

E N

O V

A

TI

O N

S

PARTITION

SCHEDULE

05/08/2025

N

O R

A N

G E A

V E G

R E E N

C O

V E S

P R

IN

G

S F L

G003

C

LA

Y C

O U

N

TY

23015

100% DOCUMENTS

STRUCTURAL ENGINEER

GM HILL ENGINEERING

9700 PHILIPS HIGHWAY, SUITE 101

JACKSONVILLE, FL 32256

MEP ENGINEER

POWELL & HINKLE

ENGINEERING, P.A.

1409 KINGSLEY AVENUE, BLDG 12A

ORANGE PARK, FL 32073

REVISIONS

# DATE DESCRIPTION

1 06/27/2025 ADDENDUM #1

1 3.1 6 72.6 3 4.14 4.4 4.8 5.25 5.6 5.9 6.8 7.321.4

8.6 8.9 9.2 9.7 9.9 10.2

I

J

J1

K

L

L2

M

D.2

8.8

A O

R

CORRIDOR

1-017

ELEVATOR

LOBBY

1-008

216 SF

SECURITY

OFFICE

1-003A

307 SF

ENTRY HALL

1-003

272 SF

SECURITY

SCREENING

1-002

944 SF

LOBBY

1-001

STAIR 4

1-007

STAIR 3

1-006

STAIR 2

1-005

STAIR 1

1-012

COC CIVIL

DIV

1-049

COMMON PATH

OF TRAVEL 56'-0"

E X

IT

E X

IT

M A

X T

R A

V E

L

D

IS

T

EXIT

34"

E X

IT

EXIT

34"

E X

IT

ASSEMBLY

OCCUPANCY

944 SF

63 OCCUPANTS

BUSINESS (B)

OCCUPANCY

25,598 SF - FLOOR AREA-GROSS

171 OCCUPANTS

FIRST FLOOR

TOTAL 1ST FLOOR AREA-GROSS : 26,216 GSF

(MEASURED TO INSIDE OF EXTERIOR WALLS,

EXCLUSIVE OF SHAFTS, INCLUSIVE OF

CORRIDORS PER FBC 202)

EXISTING

EXIT TO

REMAIN

EXISTING

EXIT TO

REMAIN

EXISTING

EXIT TO

REMAIN

EXISTING

EXIT TO

REMAIN

ENTRANCE ONLY /

NO EGRESS

LOCKABLE

SECURITY DOOR

NEW RAMP

NON EMERGENCY EGRESS (BLUE)

E X

IS

T

IN

G

R A

M P

EXISTING

EXIT TO

REMAIN

EXISTING

EXIT TO

REMAIN

EXIT

34"

W

FR

3' - 0" 1-049

W

FR

3' - 0" 1-017

W

FR

1-008 3' - 0"

W

FR

6' - 0" 1-003

W F R1 -0

A

W

FR

1-002 3' - 0"

CR

CR

TE

LIFE SAFETY PLAN LEGEND

WALL MOUNTED FIRE EXTINGUISHER - 5 LB

DRY CHEMICAL - 2A-10BC RATING.

PROVIDE WALL BRACKET

FIRE EXTINGUISHER - 5 LB WET

CHEMICAL CLASS "K" FOR KITCHEN -

2A-10BC RATING. - LOCATE UNDER SINK

IN EA RESIDENTIAL UNIT (TYP)

SEMI-RECESSED FIRE EXTINGUISHER &

CABINET - 5 LB DRY CHEMICAL- 2A-10BC

RATING.

FE

FEK

FEC

DIRECTION OF TRAVEL

EXIT DISCHARGE

POINT OF BEGINNING FOR EXIT TRAVEL

WALL MTD ACCESS CONTROL DEVICE (CARD

READER OR SIM) TO BE COORDINATED WITH

OWNER'S SECURITY VENDOR AND DOOR

HARDWARE

CR

INTERCOM LOCATION - ACCESS TO BE

COORDINATED WITH OWNER'S SECURITY

AND TELECOM VENDOR

AUTOMATIC DOOR ACTUATOR

AREA OF REFUGE (30" X 48") - PROVIDE

NECESSARY TWO-WAY COMMUNICATION

DEVICE (SEE ELEC).

PROVIDE ACRYLIC IDENTIFICATION SIGNAGE

COMPLYING WITH FBC 1013.4.

SEE SIGNAGE TYPES LISTED ABOVE.

SEE SECTION 10 1400 - SIGNAGE.

IC

DO

FIRE SUPPRESSION STANDPIPESP

FIRE PUMPFP

SIGN INDICATING "AREA OF REFUGE"AR1

SIGN INDICATING "AREA OF REFUGE"

WHICH ALSO PROVIDES DIRECTIONS FOR

THE USE OF THE TWO-WAY

COMMUNICATION SYSTEM &

INSTRUCTIONS FOR SUMMONING

ASSISTANCE VIA THE TWO-WAY

COMMUNICATION SYSTEM.

AR2

SIGN INDICATING DIRECTIONS TO REACH

AREA OF REFUGE

AR3

EXIT

34"

MAX. TRAVEL DISTANCE

REQUIRED ACCESSIBLE PUBLIC ENTRANCE

EXIT SIGN

TACTILE EXIT SIGN

EMERGENCY EXIT LIGHT

EXISTING UNRATED WALL

EXISTING 1-HOUR RATED WALL

EXISTING 2-HOUR RATED WALL

EXISTING 3-HOUR RATED WALL

EXISTING SMOKE RATED WALL

NEW UNRATED WALL

NEW 1-HOUR RATED WALL

NEW 2-HOUR RATED WALL

NEW 3-HOUR RATED WALL

NEW SMOKE RATED WALL

E X

IS

T

N G

W A

L L S

A R

E S

H A

D E

D G

R A

Y

WALL DESIGNATIONS

DATE:

PROJECT NO.:PROJECT NO.:

THIS DRAWING IS AN INSTRUMENT OF SERVICE

AND IS THE PROPERTY OF DASHER HURST

ARCHITECTS, PA. IT SHALL NOT BE

REPRODUCED IN WHOLE OR IN PART WITHOUT

THE EXPRESS WRITTEN PERMISSION OF DASHER

HURST ARCHITECTS, PA.

DASHER HURST

1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8

A R C H I T E C T S

J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4

P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0

F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5

W. W. W. D A S H E R H U R S T . C O M

C O

U R

TH

O

U S E R

E N

O V

A

TI

O N

S

1ST FLOOR

LIFE SAFETY

PLAN

05/08/2025

N

O R

A N

G E A

V E G

R E E N

C O

V E S

P R

IN

G

S F L

G101

C

LA

Y C

O U

N

TY

23015

100% DOCUMENTS

STRUCTURAL ENGINEER

GM HILL ENGINEERING

9700 PHILIPS HIGHWAY, SUITE 101

JACKSONVILLE, FL 32256

MEP ENGINEER

POWELL & HINKLE

ENGINEERING, P.A.

1409 KINGSLEY AVENUE, BLDG 12A

ORANGE PARK, FL 32073

S N

E W

1/8" = 1'-0"

1ST FLOOR LIFE SAFETY PLAN

TOTAL OCCUPANTS 194

BUSINESS TOTAL 795 150 6

ASSEMBLY TOTAL 944 15 63

AREA - GROSS 1,739

HATCH AREA RATE OCCUPANTS

1ST FLR - NEW OCCUPANCY CALCULATION

TOTAL OCCUPANTS 171

BUSINESS 25598 150 171

EXISTING AREA - GROSS 25598

HATCH AREA RATE OCCUPANTS

1ST FLR - EXISTING OCCUPANCY CALCULATION (OUTSIDE SOW)

REVISIONS

# DATE DESCRIPTION

1 06/27/2025 ADDENDUM #1

A O

R

FEC FEC

FEC

FEC

FEC

F E

C

TE

LIFE SAFETY PLAN LEGEND

WALL MOUNTED FIRE EXTINGUISHER - 5 LB

DRY CHEMICAL - 2A-10BC RATING.

PROVIDE WALL BRACKET

FIRE EXTINGUISHER - 5 LB WET

CHEMICAL CLASS "K" FOR KITCHEN -

2A-10BC RATING. - LOCATE UNDER SINK

IN EA RESIDENTIAL UNIT (TYP)

SEMI-RECESSED FIRE EXTINGUISHER &

CABINET - 5 LB DRY CHEMICAL- 2A-10BC

RATING.

FE

FEK

FEC

DIRECTION OF TRAVEL

EXIT DISCHARGE

POINT OF BEGINNING FOR EXIT TRAVEL

WALL MTD ACCESS CONTROL DEVICE (CARD

READER OR SIM) TO BE COORDINATED WITH

OWNER'S SECURITY VENDOR AND DOOR

HARDWARE

CR

INTERCOM LOCATION - ACCESS TO BE

COORDINATED WITH OWNER'S SECURITY

AND TELECOM VENDOR

AUTOMATIC DOOR ACTUATOR

AREA OF REFUGE (30" X 48") - PROVIDE

NECESSARY TWO-WAY COMMUNICATION

DEVICE (SEE ELEC).

PROVIDE ACRYLIC IDENTIFICATION SIGNAGE

COMPLYING WITH FBC 1013.4.

SEE SIGNAGE TYPES LISTED ABOVE.

SEE SECTION 10 1400 - SIGNAGE.

IC

DO

FIRE SUPPRESSION STANDPIPESP

FIRE PUMPFP

SIGN INDICATING "AREA OF REFUGE"AR1

SIGN INDICATING "AREA OF REFUGE"

WHICH ALSO PROVIDES DIRECTIONS FOR

THE USE OF THE TWO-WAY

COMMUNICATION SYSTEM &

INSTRUCTIONS FOR SUMMONING

ASSISTANCE VIA THE TWO-WAY

COMMUNICATION SYSTEM.

AR2

SIGN INDICATING DIRECTIONS TO REACH

AREA OF REFUGE

AR3

EXIT

34"

MAX. TRAVEL DISTANCE

REQUIRED ACCESSIBLE PUBLIC ENTRANCE

EXIT SIGN

TACTILE EXIT SIGN

EMERGENCY EXIT LIGHT

EXISTING UNRATED WALL

EXISTING 1-HOUR RATED WALL

EXISTING 2-HOUR RATED WALL

EXISTING 3-HOUR RATED WALL

EXISTING SMOKE RATED WALL

NEW UNRATED WALL

NEW 1-HOUR RATED WALL

NEW 2-HOUR RATED WALL

NEW 3-HOUR RATED WALL

NEW SMOKE RATED WALL

E X

IS

T

N G

W A

L L S

A R

E S

H A

D E

D G

R A

Y

WALL DESIGNATIONS

E X

IT

E X

IT

C O

M M

O N P

ATH

F T

R

AVEL 3

6' -0

MAX TRAVEL

DIST 129'-6"

COMMON PATH

OF TRAVEL 52'-6"

ASSEMBLY

OCCUPANCY

323 SF

22 OCCUPANTS

ASSEMBLY

OCCUPANCY

390 SF

26 OCCUPANTS

BUSINESS (B)

OCCUPANCY

13,654 SF - FLOOR AREA-GROSS

76 OCCUPANTS

SECOND FLOOR

TOTAL 2ND FLOOR AREA-GROSS : 26,216 GSF

(MEASURED TO INSIDE OF EXTERIOR WALLS,

EXCLUSIVE OF SHAFTS, INCLUSIVE OF

CORRIDORS PER FBC 202)

CR

CR

CR

CR

CRCR

CR

IC

218 SF

WOMEN'S

202 SF

MEN'S

241 SF

CORR

55 SF

ELEV. 1

409 SF

LOBBY

56 SF

TOILET

56 SF

TOILET

121 SF

OFFICE

2077 SF

OPEN

OFFICE

99 SF

EVIDENCE

STORAGE

121 SF

OFFICE

224 SF

CONFERENCE

241 SF

BREAK

340 SF

CORR

71 SF

CORR

37 SF

CONF.

BOOTH

656 SF

ELEV LOBBY

522 SF

PUBLIC

CORRIDOR

153 SF

CENTRAL

CASH

COUNTING

75 SF

ELEV. 6

193 SF

ELEC / TELE

642 SF

CORRIDOR

152 SF

WAITING

AREA

204 SF

JUDICIAL

ASSISTANT

200 SF

JUDICIAL

ASSISTANT

410 SF

CHAMBER

385 SF

CHAMBER

217 SF

JUDGE

OFFICE

224 SF

JUDGE

OFFICE

44 SF

TOILET

47 SF

TOILET

97 SF

SEMI-PRIVACY

ROOM

91 SF

COPY/FILE

182 SF

CORR

505 SF

MECH

ROOM

134 SF

HOLDING

CELL

136 SF

HOLDING

CELL

74 SF

CORR

53 SF

TOILET

53 SF

TOILET

222 SF

STAIR 3

232 SF

STAIR 2

201 SF

CORR

28 SF

CONF.

BOOTH

221 SF

STAIR 4

195 SF

JUDGE

OFFICE401 SF

CHAMBER

370 SF

CHAMBER

215 SF

JUDGE

OFFICE

49 SF

TOILET

96 SF

SEMI-PRIV

ROOM

191 SF

JUDICIAL

ASSISTANT

151 SF

WAITING

AREA

201 SF

JUDICIAL

ASSISTANT

92 SF

SEMI-PRIV

ROOM

49 SF

TOILET

250 SF

FLEX OFFICE

63 SF

ELEC

78 SF

ELEV 5

134 SF

EVIDENCE

STORAGE

48 SF

ELEV 4

136 SF

FILE ROOM

S F

S E R

V E R

S

F C

O R

R

ID

O R

1612 SF

PUBLIC

CORRIDOR

163 SF

DEPT HEAD

181 SF

DEPT HEAD

181 SF

DEPT HEAD

168 SF

DEPT HEAD

113 SF

OFFICE

113 SF

OFFICE

145 SF

OFFICE

305 SF

CONFERENCE

S

F B

R E A

K R

M

114 SF

OFFICE

114 SF

OFFICE

59 SF

LGL ASST

55 SF

LGL ASST

64 SF

LGL ASST

64 SF

LGL ASST

59 SF

LGL ASST

64 SF

LGL ASST

64 SF

LGL ASST

57 SF

LGL ASST3

S

F C

O P

Y A

R E A

S F

C O

P Y

A R

E A

146 SF

OFFICE

54 SF

STORAGE

40 SF

ELEV

ACCESS

126 SF

OPEN

SPACE

244 SF

OFFICE FOR

CHILDREN

106 SF

WOMENS RR

77 SF

MEN RR

32 SF

JC

112 SF

OFFICE

395 SF

CORRIDOR

64 SF

CORRIDOR

S

F C

O R

R

ID

O R

8 SF

DUMBWAITER

285 SF

STORAGE

58 SF

LGL ASST

58 SF

LGL ASST

58 SF

LGL ASST

58 SF

LGL ASST

142 SF

OFFICE 134 SF

VICT ADV

142 SF

VICT ADV

142 SF

VICT ADV

144 SF

OFFICE151 SF

OFFICE

S F

LG

L

A S S T

S F

LG

L

A S S T

S F

LG

L

A S S T

28 SF

COPY AREA

S

F C

O R

R

ID

O R

S

F C

O R

R

ID

O R

221 SF

LOBBY

120 SF

RECEPT

613 SF

CORRIDOR

221 SF

DEPOS RM

150 SF

CHILD DEPO

RM

CRCR

CR

CR

CR

CR

ASSEMBLY

OCCUPANCY

152 SF

11 OCCUPANTS

ASSEMBLY

OCCUPANCY

222 SF

15 OCCUPANTS

ASSEMBLY

OCCUPANCY

221 SF

15 OCCUPANTS

MAX TRAVEL

DIST 175'-6"

C O

M M

O N

P A

T H

F

T R

A V

E L

OPEN WORK STATIONS

O P

E N

W O

R K

S T

A T

IO

N

S

OPEN WORK STATIONS

OPEN WORK STATIONS

OPEN WORK

STATIONS

C O M

M O N P

TH

F T

R A V

EL 5

6' -6

MAX TRAVEL

DIST 163'-6"

SINGLE MEANS OF

EGRESS FOR A

CUMULATIVE OCCUPANT

LOAD OF 41

FEC

FEC

EXISTING

EXTINGUISHER

FEC

ASSEMBLY

OCCUPANCY

360 SF

24 OCCUPANTS

E X

IT

EXIT

34"

57 SF

ELEV. 2

74 SF

ELEV. 3

223 SF

STAIR 1

205 SF

ELEV

MACHINE

36 SF

JC

151 SF

SECURITY

EQUIP. RM

COMMON PATH

OF TRAVEL 44'-0"

MAX TRAVEL

DIST 210'-6"

W

FR

2-101 6' - 0"

3/4 HR

W

FR

2-300 6' - 0"

3/4 HR

W

FR

2-304 3' - 0"

W

FR

2-303 3' - 0"

W

FR

2-302 3' - 0"

W

FR

2-300A 3' - 0"

W

FR

2-300B 3' - 0"

W

FR

2-301 3' - 0"

W F R2

-3

W

FR

3' - 0" 2-328

W

FR

3' - 0" 2-326

W

FR

3' - 0" 2-325

W

FR

3' - 0" 2-312

W

FR

3' - 0" 2-313

W

FR

3' - 0" 2-323

W

FR

3' - 0" 2-321

W

FR

3' - 0" 2-322

W

FR

2-314 6' - 0"

W

FR

2-315 3' - 0"

W

FR

2-341 3' - 0"

W F R2

-3

W

FR

2-316 3' - 0"

W

FR

3' - 0" 2-352

W

FR

3' - 0" 2-351

W

FR

3' - 0" 2-353

W

FR

3' - 0" 2-354

W

FR

3' - 0" 2-355

W

FR

3' - 0" 2-356

W

FR

2-350 3' - 0"

3/4 HR

W

FR

2-357 3' - 0"

W

FR

3' - 0" 2-332

W

FR

3' - 0" 2-331

W

FR

2-335 3' - 0"

W

FR

2-334 3' - 0"

W

FR

2-336 3' - 0"

W

FR

2-336A 3' - 0"

W

FR

2-334A 3' - 0"

W

FR

2-330 3' - 0"

3/4 HR

W

FR

2-333 3' - 0"

W

FR

2-333A 3' - 0"

3/4 HR

W

FR

2-422 3' - 0"

W

FR

2-421 3' - 0"

W

FR

2-424 3' - 0"

W

FR

2-420A 3' - 0"

W

FR

2-420B 3' - 0"

W

FR

2-420 3' - 0"

3/4 HR

W

FR

2-423 3' - 0"

3/4 HR

W

FR

2-410 3' - 0"

3/4 HR

W

FR

2-410B 3' - 0"

W

FR

2-410A 3' - 0"

W

FR

2-411 3' - 0"

W

FR

2-414 3' - 0"

W

FR

2-413 3' - 0"

3/4 HR

W

FR

2-412 3' - 0"

W

FR

2-400 3' - 0"

W

FR

3' - 0" 2-327

W

FR

2-017 3' - 0"

3/4 HR

CR

CR

DATE:

PROJECT NO.:PROJECT NO.:

THIS DRAWING IS AN INSTRUMENT OF SERVICE

AND IS THE PROPERTY OF DASHER HURST

ARCHITECTS, PA. IT SHALL NOT BE

REPRODUCED IN WHOLE OR IN PART WITHOUT

THE EXPRESS WRITTEN PERMISSION OF DASHER

HURST ARCHITECTS, PA.

DASHER HURST

1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8

A R C H I T E C T S

J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4

P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0

F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5

W. W. W. D A S H E R H U R S T . C O M

C O

U R

TH

O

U S E R

E N

O V

A

TI

O N

S

2ND FLOOR

LIFE SAFETY

PLAN

05/08/2025

N

O R

A N

G E A

V E G

R E E N

C O

V E S

P R

IN

G

S F L

G102

C

LA

Y C

O U

N

TY

23015

100% DOCUMENTS

STRUCTURAL ENGINEER

GM HILL ENGINEERING

9700 PHILIPS HIGHWAY, SUITE 101

JACKSONVILLE, FL 32256

MEP ENGINEER

POWELL & HINKLE

ENGINEERING, P.A.

1409 KINGSLEY AVENUE, BLDG 12A

ORANGE PARK, FL 32073

TOTAL OCCUPANTS 194

BUSINESS TOTAL 11,865 150 80

ACESSORY STORAGE / UTILITY 121 300 1

ASSEMBLY TOTAL 1,668 15 113

AREA - GROSS 13,654

HATCH AREA RATE OCCUPANTS

2ND FLR - NEW OCCUPANCY CALCULATION

S N

E W

1/8" = 1'-0"

2ND FLOOR-SOUTH WING LIFE SAFETY PLAN

TOTAL OCCUPANTS 109

BUSINESS 9171 150 62

ACESSORY STORAGE / UTILITY 1092 300 4

ASSEMBLY 633 15 43

EXISTING AREA - GROSS 10896

HATCH AREA RATE OCCUPANTS

2ND FLR - EXISTING OCCUPANCY CALCULATION (OUTSIDE SOW)

REVISIONS

# DATE DESCRIPTION

FEC FEC

FEC

FEC

FEC

F E

C

DN

STAIR 3

4-006

CHAMBER

4-077

JUDICIAL

ASSISTANT

4-076

COPY/FILE

WORK AREA

4-075

CHAMBER

4-081

JUDGE

OFFICE

4-082

JUDICIAL

ASSISTANT

4-080

JUDICIAL

TOILET

4-083

TOILET

4-086

TOILET

4-085

JURY

ROOM-1

4-087

JUDGE

OFFICE

4-078

JUDICIAL

TOILET

4-079

CORR

4-084

CTRM

STORAGE

4-061

CTRM

STORAGE

4-058

ELEVATOR 4

4-059

ELEVATOR 5

4-060

CORRIDOR

4-057

CORR

4-056

ELEC

4-072

DUMB

WAITER

4-073

1 1.4

1.4

2.6

2.6

3.1

3.1

4.1

4.1

4.4

4.4

4.8

4.8

5.2

5.2

5.6

5.6

5.9

5.9

6.8

6.8

7.3

7.3

8.7

8.7

9.1

9.1

AA

BB

CC

DD

EE

FF

GG

HH

2.8

2.8

8.8

8.8

9.2

9.2

B.3B.3

WOMEN'S

2-015

MEN'S

2-014

CORR

2-008

ELEV. 1

2-009

LOBBY

2-101

TOILET

2-112

TOILET

2-113

OFFICE

2-110

OPEN

OFFICE

2-104

EVIDENCE

STORAGE

2-105

OFFICE

2-111

CONFERENCE

2-108

BREAK

2-109

CORR

2-107

CORR

2-106

CONF.

BOOTH

2-102

ELEV LOBBY

2-003PUBLIC

CORRIDOR

2-003A

CENTRAL

CASH

COUNTING

2-103

ELEV. 6

2-031

ELEC / TELE

2-030

CORRIDOR

2-018

WAITING

AREA

2-019

JUDICIAL

ASSISTANT

2-025

JUDICIAL

ASSISTANT

2-020

CHAMBER

2-029

CHAMBER

2-024

JUDGE

OFFICE

2-027

JUDGE

OFFICE

2-022

TOILET

2-023

TOILET

2-028

SEMI-PRIVACY

ROOM

2-026

COPY/FILE

2-021

CORR

2-017

MECH

ROOM

2-032

HOLDING

CELL

2-203

HOLDING

CELL

2-202

CORR

2-039

TOILET

2-038

TOILET

2-037

STAIR 3

2-006

STAIR 2

2-005

CORR

2-204

CONF.

BOOTH

2-201

STAIR 4

2-007JUDGE

OFFICE

2-411CHAMBER

2-410

CHAMBER

2-420

JUDGE

OFFICE

2-421

TOILET

2-422

SEMI-PRIV

ROOM

2-424

JUDICIAL

ASSISTANT

2-423

WAITING

AREA

2-018A

JUDICIAL

ASSISTANT

2-413

SEMI-PRIV

ROOM

2-414

TOILET

2-412

FLEX OFFICE

2-400

ELEC

2-034

ELEV 5

2-036

EVIDENCE

STORAGE

2-341

ELEV 4

2-035

FILE ROOM

2-315

S E R

V E R

-3

C O

R R

ID

O

R

-3

PUBLIC

CORRIDOR

2-003B

DEPT HEAD

2-356

DEPT HEAD

2-355

DEPT HEAD

2-354

DEPT HEAD

2-353

OFFICE

2-352

OFFICE

2-351

OFFICE

2-331

CONFERENCE

2-357

BREAK RM

2-316

OFFICE

2-321

OFFICE

2-322

LGL ASST

2-310B

LGL ASST

2-310A

LGL ASST

2-343D

LGL ASST

2-343E

LGL ASST

2-343F

LGL ASST

2-343A

LGL ASST

2-343B

LGL ASST

2-343C

C O

P Y

A R

E A

-3

A

COPY AREA

2-310C

OFFICE

2-332

STORAGE

2-314

ELEV

ACCESS

2-018B

OPEN

SPACE

2-343

DESIGN AREA 2B

JUDGE'S CHAMBERS

DESIGN AREA 1

SHADED SOLID GRAY

(NIC)

OFFICE FOR

CHILDREN

2-304

WOMENS RR

2-336

MEN RR

2-334

JC

2-335

OFFICE

2-323

CORRIDOR

2-324

CORRIDOR

2-340

A403

A705

A7058

A705 7

A7056

A705

A403

C O

R R

ID

O

R

-3

DUMBWAITER

2-033

STORAGE

2-333

LGL ASST

2-324B

LGL ASST

2-324C

LGL ASST

2-324C

LGL ASST

2-324D

OFFICE

2-325

VICT ADV

2-326

VICT ADV

2-327

VICT ADV

2-328

OFFICE

2-312

OFFICE

2-313

LGL ASST

2-320C

LGL ASST

2-320B

LGL ASST

2-320A

COPY AREA

2-324A

A705

C O

R R

ID

O

R

-3

C O

R R

ID

O

R

-3

LOBBY

2-300

RECEPT

2-311

CORRIDOR

2-310

DEPOS RM

2-302

CHILD DEPO

RM

2-303

CR

CR

CR

CR

CRCR

CR

IC

CRCR

CR

CR

CR

CR

2-101

2-300

SE4A

SE4A F2

S4BA

S4BA

S4BA

SE4

S4BA

2-304

2-303

2-302

2-300A

2-300B

2-301

2-311

S4BA

S4BAS4BAS4BA

2-3282-3262-325

S4BA

S4BA S4BA

SE4

2-3122-313

2-323

2-321

2-322

2-314

S4BA

S4BA

S4BA

S4BA

F2

F2

M8

SC41A S4E

2-315

M8

M8

M8

S4BA

SC41A

F2

FS3SE4

2-341

2-342

2-316

S4A

S4BA

S E

A

S

B A

S4BA

S4BA

S4BA

S E

SE4

S4BA

2-352

2-351

SE4

HM

HM

HM

F2

SE4

2-353

2-354

2-355

2-356

2-350

S4BA

S4BA

S4BA

F2

SE4

F2

SE4

F2

SE4

F2

SE4

S4BA

2-357

SE4 SE4

S4BA

F2

F2

SE4

SC41A

SC41A

SE4

SE4

2-332

2-331

-3

2-334

2-336

2-336A

2-334A

-3

2-333

2-333A

S4BA

S4BASE4

F2

F2

S4BA SE4

S4BA

S C

A

SC41ASE4

S6BA

-4

2-421

2-424

2-420A

S6BA

SE4A SE4A

2-420B

2-420

2-423

2-410

2-410B

2-410A 2-411

2-414

2-413

-4

2-400

S6BA

S6BA

S6BA

S6C1

SC41A

S6BA

S6BA

S6BA

SE4A SE4A

F2 F2 F2 F2

SE4 SE4 SE4

F2

SE4A

SE4

HM

HM

A705

A705

A403

A403

A403

A403

A403

A403

A403

A403

A403

SIM

2-327

2-017

STAIR 1

2-368

A D

J U

S T

A B

E

L V

IN

G

S

E E

D T

L

A D

J U

S T

A B

E

L V

IN

G

S

E E

D T

L

A602

A102

34TH FLR

A102

24TH FLR

GC TO INFILL SLAB

RECESSES & LEVEL

EXISTING FLOOR AS

NECESSARY FOR

INSTALLATION OF NEW

FLOOR. SEE DEMO

FLOOR PLAN

GC TO INFILL

SLAB

CR

CR

1 1.4 2.6 33.1 44.1 4.4 4.8 5 5.2

AA

BB

2.8

B.3B.3

2 20

NEW EXHAUST CHASE.

VERIFY SIZE W/ HVAC.

REPAIR / FINISH TO

MATCH ROOM2' - 1"

1'

SS22

33.1 44.1

CC

DD

FUR OUT WALL FOR

NEW HVAC

CONDUIT. FINISH/

REPAIR TO MATCH

EXISTING

FS3

1'

DATE:

PROJECT NO.:PROJECT NO.:

THIS DRAWING IS AN INSTRUMENT OF SERVICE

AND IS THE PROPERTY OF DASHER HURST

ARCHITECTS, PA. IT SHALL NOT BE

REPRODUCED IN WHOLE OR IN PART WITHOUT

THE EXPRESS WRITTEN PERMISSION OF DASHER

HURST ARCHITECTS, PA.

DASHER HURST

1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8

A R C H I T E C T S

J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4

P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0

F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5

W. W. W. D A S H E R H U R S T . C O M

C O

U R

TH

O

U S E R

E N

O V

A

TI

O N

S

FLOOR

PLAN - 2ND

& 4TH FLR

05/08/2025

N

O R

A N

G E A

V E G

R E E N

C O

V E S

P R

IN

G

S F L

A102

C

LA

Y C

O U

N

TY

23015

100% DOCUMENTS

STRUCTURAL ENGINEER

GM HILL ENGINEERING

9700 PHILIPS HIGHWAY, SUITE 101

JACKSONVILLE, FL 32256

MEP ENGINEER

POWELL & HINKLE

ENGINEERING, P.A.

1409 KINGSLEY AVENUE, BLDG 12A

ORANGE PARK, FL 32073

S N

E W

1/8" = 1'-0"

2ND FLOOR-SOUTH WING (NEW CONST)

1/8" = 1'-0"

PARTIAL 4TH FLOOR PLAN - DUCTWORK CHASE

1/8" = 1'-0"

PARTIAL 4TH FLOOR PLAN - HVAC CONDUIT

REVISIONS

# DATE DESCRIPTION

FEC

FEC

F E

C

1 1.4

1.4

2.6

2.6

3.1

3.1

4.1

4.1

4.4

4.4

4.8

4.8

5.2

5.2

5.6

5.6

5.9

5.9

6.8

6.8

7.3

7.3

8.7

8.7

9.1

9.1

AA

BB

CC

DD

EE

FF

GG

HH

2.8

2.8

8.8

8.8

9.2

9.2

9.4

9.4

9.9

9.9

B.3B.3

A802

2-015

2-014

2-008

2-009

2-101

2-1122-113

2-110

2-104

2-105

2-111

2-1082-109

2-107

2-106

2-102

2-003

2-003A

2-103

2-031

2-030

F

B

W

LVT1

P4

VB1

2-018

2-019 2-025 2-020

2-029 2-0242-027 2-022

2-0232-028

2-026 2-021

2-017

2-032

2-203

2-202

2-039

2-038

2-037

2-006

2-005

2-204

2-201

2-007F

B

W

CBT1

P4

VB1

2-411 F

B

W

CBT1

P4

VB1

2-410 F

B

W

CBT1

P4

VB1

2-420 F

B

W

CBT1

P4

VB1

2-421

F

B

W

PCT1

P5

PCB1

2-422

F

B

W

CBT1

P4

VB1

2-424

F

B

W

CBT1

P4

VB1

2-423 F

B

W

LVT1

P4

VB1

2-018A F

B

W

CBT1

P4

VB1

2-413

F

B

W

CBT1

P4

VB1

2-414

F

B

W

PCT1

P5

PCB1

2-412

F

B

W

CBT1

P4

VB1

2-400

2-034

2-036

F

B

W

CPT1

P4

VB1

2-341

2-035

F

B

W

CPT1

P4

VB1

2-315

F B W

C P

T1

P

V B

-3

F

B

W

CPT1

P4

VB1

2-301

F

B

W

PCT2&3

P3

PCB2

2-003B

F

B

W

CPT1

P4

VB1

2-356

F

B

W

CPT1

P4

VB1

2-355

F

B

W

CPT1

P4

VB1

2-354

F

B

W

CPT1

P4

VB1

2-353

F

B

W

CPT1

P4

VB1

2-352

F

B

W

CPT1

P4

VB1

2-351

F

B

W

CPT1

P4

VB1

2-331

F

B

W

CPT1

P4

VB1

2-357

F

B

W

LVT1

P4

VB1

2-316

F

B

W

CPT1

P4

VB1

2-321

F

B

W

CPT1

P4

VB1

2-322

F B W

C P

T1

P

V B

-3

A

F

B

W

CPT1

P4

VB1

2-332

F

B

W

CPT1

P4

VB1

2-314

F

B

W

CPT1

P4

VB1

2-343

F

B

W

CPT1

P4

VB1

2-304

F

B

W

PCT1

P5

PCB1

2-336

F

B

W

PCT1

P5

PCB1

2-334

F

B

W

PCT1

P5

PCB1

2-335

F

B

W

CPT1

P4

VB1

2-323 F

B

W

CPT1

P4

VB1

2-324

F

B

W

CPT1

P4

VB1

2-340

F B W

C P

T1

P

V B

-3

2-033

F

B

W

CPT1

P4

VB1

2-333

F

B

W

CPT1

P4

VB1

2-325 F

B

W

CPT1

P4

VB1

2-326 F

B

W

CPT1

P4

VB1

2-327 F

B

W

CPT1

P4

VB1

2-328

F

B

W

CPT1

P4

VB1

2-312 F

B

W

CPT1

P4

VB1

2-313

F

B

W

CPT1

P4

VB1

2-324A

F

B

W

CPT1

P4

VB1

2-330

F

B

W

CPT1

P4

VB1

2-320

F

B

W

CPT1

P4

VB1

2-300

F

B

W

CPT1

P4

VB1

2-311

F

B

W

CPT1

P4

VB1

2-310

F

B

W

CPT1

P4

VB1

2-302

F

B

W

CPT1

P4

VB1

2-303

EXTEND TILE PATTERN EXTEND TILE PATTERNEXTEND TILE PATTERN

2-368

REMOVE EXISTING BROADLOOM CARPET AND REPLACE W/ LVT1

& VB1 IN EXISTING CORRIDOR (DIAGONAL HATCH AREA = +/- 1325

SF). PAINT WALLS PER ROOM ROOM # 2-018 - SEE FINISH SCHED

REMOVE EXISTING

BROADLOOM

CARPET AND REPLACE W/

LVT1 & PAINT WALLS

UNTIL END OF BUILDING

WING

A802

REMOVE EXISTING CARPET AND REPLACE W/ CPT1 & VB1 IN

EXISTING JUDGES CHAMBERS. (CROSSHATCH AREA) = +/- 2022

SF). ADD ALTERNATE 5

ALIGN EDGE OF TILE WITH

EXISTING CORRIDOR

PCT2

PCT3

PCT2

PCT2

F

U

LL

T

IL

E S

O N

D

IA

G O

N A

L

EXISTING

CORRIDOR TILE

REMOVE EXSITING. CUT

TILES AS REQ'D TO

INSTALL NEW TILE

DATE:

PROJECT NO.:PROJECT NO.:

THIS DRAWING IS AN INSTRUMENT OF SERVICE

AND IS THE PROPERTY OF DASHER HURST

ARCHITECTS, PA. IT SHALL NOT BE

REPRODUCED IN WHOLE OR IN PART WITHOUT

THE EXPRESS WRITTEN PERMISSION OF DASHER

HURST ARCHITECTS, PA.

DASHER HURST

1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8

A R C H I T E C T S

J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4

P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0

F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5

W. W. W. D A S H E R H U R S T . C O M

C O

U R

TH

O

U S E R

E N

O V

A

TI

O N

S

FINISH

FLOOR

PLAN - 2ND

FLOOR

05/08/2025

N

O R

A N

G E A

V E G

R E E N

C O

V E S

P R

IN

G

S F L

A102B

C

LA

Y C

O U

N

TY

23015

100% DOCUMENTS

STRUCTURAL ENGINEER

GM HILL ENGINEERING

9700 PHILIPS HIGHWAY, SUITE 101

JACKSONVILLE, FL 32256

MEP ENGINEER

POWELL & HINKLE

ENGINEERING, P.A.

1409 KINGSLEY AVENUE, BLDG 12A

ORANGE PARK, FL 32073

S N

E W

1/8" = 1'-0"

2ND FLOOR-SOUTH WING (NEW CONST) FINISH PLAN

1/4" = 1'-0"

2ND FLOOR CORRIDOR FINISH PLAN

PT8PT8

REVISIONS

# DATE DESCRIPTION

FEC

FEC

F E

C

1 1.4

1.4

2.6

2.6

3.1

3.1

4.1

4.1

4.4

4.4

4.8

4.8

5.2

5.2

5.6

5.6

5.9

5.9

6.8

6.8

7.3

7.3

8.7

8.7

9.1

9.1

AA

BB

CC

DD

EE

FF

GG

HH

2.8

2.8

8.8

8.8

9.2

9.2

B.3B.3

WOMEN'S

MEN'S

CORR

ELEV. 1

ELEV. 2

LOBBY

TOILETTOILET

OFFICE

OPEN

OFFICE

EVIDENCE

STORAGE

OFFICE

CONFERENCEBREAK

CORR

CORR

CONF.

BOOTH

ELEV LOBBY

PUBLIC

CORRIDOR

CENTRAL

CASH

COUNTING

ELEV. 6

ELEC / TELE

WAITING

AREA

JUDICIAL

ASSISTANT

JUDICIAL

ASSISTANT

CHAMBER CHAMBER

JUDGE

OFFICE

JUDGE

OFFICE

TOILETTOILET

SEMI-PRIVACY

ROOM COPY/FILE

CORR

MECH

ROOM

HOLDING

CELL

HOLDING

CELL

CORR

TOILET

TOILET

STAIR 3

STAIR 2

CORR

CONF.

BOOTH

STAIR 4

JUDGE

OFFICE

CHAMBERCHAMBER

JUDGE

OFFICE

TOILET

SEMI-PRIV

ROOM

JUDICIAL

ASSISTANT WAITING

AREA

JUDICIAL

ASSISTANT

SEMI-PRIV

ROOM

TOILET

FLEX OFFICE

ELEC

ELEV 5

EVIDENCE

STORAGE

ELEV 4

FILE ROOM

S E R

V E R

C O

R R

ID

O

R

PUBLIC

CORRIDOR

DEPT HEAD

DEPT HEAD

DEPT HEAD

DEPT HEAD

OFFICE

OFFICE

OFFICE

CONFERENCE

BREAK RM

OFFICE

OFFICE

LGL ASST LGL ASST

LGL ASST LGL ASST LGL ASST

LGL ASST LGL ASST LGL ASST

C O

P Y

A R

E A

C O

P Y

A R

E A

OFFICE

STORAGE

ELEV

ACCESS

OPEN

SPACE

CHILDREN

CONFERENCE

ENCLOSED OFFICES

ENCLOSED OFFICES - DEPT HEAD

JUDGE'S CHAMBERS

PARTIAL HEIGHT WORKSTATIONS

RESTROOM STAFF

DEPOSITION

CIRCULATION STAFF

LOBBY

COPY AREA

EXISTING MASONRY WALLED

ROOMS

STORAGE

DESIGN AREA 2B

JUDGE'S CHAMBERS

DESIGN AREA 1

(completed)

10'3" x 22'10"

20'6" x 15'11"

17' x 8'4

16'10 x 8'4

4'8 x 12'

11'10 x 9'8"

7'10 x 8' 7'10 x 8' 7'10 x 8'

7'10 x 8' 7'10 x 8' 7'10 x 8'

7'10 x 8' 7'10 x 7'10

OFFICE FOR

CHILDREN

OFFICE

WOMENS RR

MEN RR

JC

CORRIDOR

CORRIDOR

12'4 x 9'7

12'4 x 9'7

11'0 x 14'4

11'10 x 9'8"

11'10 x 9'8"

C O

R R

ID

O

R

PRINTER

SHREDDER

S H

R E

D D

E R

P R

IN

T

E R

T V

W

E B

C A

M

LGL ASST

COPY AREA

LGL ASST

STORAGE

LGL ASST LGL ASST

LGL ASST

LGL ASST

LGL ASST

OFFICE OFFICE

OFFICE VICT ADV VICT ADV VICT ADV

11'0 x 14'4

7'0 x 8'3 7'0 x 8'3 7'0 x 8'3 7'0 x 8'3

8'0 x 8'0

8'0 x 8'0

8'0 x 8'0

11'3 x 12'7

10'8 x 13'4 10'8 x 13'4

15'9 x 15'9

11'10 x 14'2

11'10 x 15'5

11'10 x 15'5

11'10 x 15'5

PRINTER

SHREDDER

CORRIDOR

C O

R R

ID

O

R

DEPOS RM

CHILD DEPO

RMRECEPT

LOBBY

7'4 x 16'4

12'8 x 17'4

15'9 x 11'3

21'2 x 9'9

CORRIDOR

T V

W

E B

C A

M

T V

W

E B

C A

M

T V

W

E B

C A

M 11'3 x 12'711'3 x 12'711'3 x 12'7

CR

CR

CR

CR

CRCR

CR

IC

CRCR

CR

CR

CR

CR

CR

CR

DATE:

PROJECT NO.:PROJECT NO.:

THIS DRAWING IS AN INSTRUMENT OF SERVICE

AND IS THE PROPERTY OF DASHER HURST

ARCHITECTS, PA. IT SHALL NOT BE

REPRODUCED IN WHOLE OR IN PART WITHOUT

THE EXPRESS WRITTEN PERMISSION OF DASHER

HURST ARCHITECTS, PA.

DASHER HURST

1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8

A R C H I T E C T S

J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4

P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0

F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5

W. W. W. D A S H E R H U R S T . C O M

C O

U R

TH

O

U S E R

E N

O V

A

TI

O N

S

FLOOR

PLAN - 2ND

FLOOR

(COLORED)

05/08/2025

N

O R

A N

G E A

V E G

R E E N

C O

V E S

P R

IN

G

S F L

A102C

C

LA

Y C

O U

N

TY

23015

100% DOCUMENTS

STRUCTURAL ENGINEER

GM HILL ENGINEERING

9700 PHILIPS HIGHWAY, SUITE 101

JACKSONVILLE, FL 32256

MEP ENGINEER

POWELL & HINKLE

ENGINEERING, P.A.

1409 KINGSLEY AVENUE, BLDG 12A

ORANGE PARK, FL 32073

ENCLOSED OFFICES

17 SHOWN

15 WORKSTATIONS SHOWN

S N

E W

1/8" = 1'-0"

2ND FLOOR-SOUTH WING (COLOR)

REVISIONS

# DATE DESCRIPTION

1 06/27/2025 ADDENDUM #1

NEW

SECURITY

CHECKPOINT

NEW SECURITY SCREENING SYSTEM - BASED

ON EVOLV EXPRESS TECHNOLOGY -

CONFIRM ELECTRICAL REQUIREMENTS.

POWER/DATA TO BE PROVIDED VIA NEW LOW

WALL

PARTIAL HEIGHT WOOD

WALL (MATCH EXISTING

FINISH) W/ BALLISTIC INNER

LAYER

PARTIAL HEIGHT

WOOD WALL (MATCH

EXISTING FINISH)

GUN SAFE

BY OWNER

WORKSURFACE

NEW GLASS BALLISTIC STOREFRONT

SYSTEM - DOOR TO BE TIED TO

SECURITY SYSTEM AND

AUTOMATICALLY CLOSED/LOCKED VIA

PUSHBUTTON AT SECURITY

WORKSTATION

S E

C U

R

IT

Y

A

C O

V E

SECURITY

PRIVATE

SCREENING

AREA

QUEUE

SECURITY

STATION

BALLISTIC GLAZING

FROM WOOD CAP TO

CEILING

NEW

DOOR

DEMO EXISTING LOW

WALLS (EQUIPMENT

TO BE RELOCATED)

WOOD PILASTERS TO

BE REMOVED EA SIDE

OF OPENING - WALL

FINISH TO BE

REPAIRED & PAINTED

W O

R K

S U

R F

A C

E

PARTIAL HEIGHT

WOOD WALL (MATCH

EXISTING FINISH) -

SEE ADD

ALTERNATES

A701 2

A701

A701

1-008

LOBBY

1-001

SECURITY

SCREENING

1-002

ENTRY HALL

1-003

SECURITY

OFFICE

1-003A

1-003

A7014

A701

A701 8

A701

A70110

REPAIR WALL WHERE POWER IS RUN TO

NEW DEVICE

15' - 10"

5' - 8"

1"

5'

PARTIAL HT WD WALL WITH

SWINGING GATE - PROVIDE

3.5" TS POST IN WALL TO

BRACE TO FLOOR (EACH

SIDE OF SCANNER)

A701

C O

N F

IR

M

L E

N G

T H

O F

E Q

U

IP

SF

2C

SF

2B

SF

2A

S E

C U

R

IT

B

P A

N

E

REPAIR WALL WHERE

POWER IS RUN TO NEW

DEVICE

REPAIR WALL WHERE

POWER IS RUN TO NEW

DEVICE

-0

A

1-002

ELEVATOR

LOBBY

1-008

APP1

APP3 APP2

EXISTING GWB CEILINGS TO

REMAIN - PAINT

EXISTING LIGHTING TO

REMAIN (TYP)

REMOVE & REPAIR PORTION

OF EXISTING CEILING AS

REQ'D TO INSTALL NEW

STOREFRONT - CONSTRUCT

NEW FRAMING FROM HEAD

OF STOREFRONT TO

STRUCTURE ABOVE AND

BRACE AS REQ'D

EXISTING GWB

CEILINGS TO REMAIN -

NO WORK

EXISTING GWB CEILINGS TO

REMAIN - NO WORK

NEW WOOD CORBEL

(TYP OF 2)

EXISTING WOOD SOFFIT TO

REMAIN - NO WORK

NEW CHERRY WOOD VENEER

PANEL TO INFILL VOID LEFT BY

DEMO'D WOOD COLUMN (BOTH

SIDES) - MATCH FINISH OF

EXISTING - SET FLUSH W/

EXISTING WOOD TRIM

EXISTING HVAC DIFFUSERS

TO REMAIN (TYP)

EXISTING SPRINKLER HEADS

TO REMAIN (TYP)

NEW ALUM STOREFRONT

GENERAL NOTES (1ST FLR)

1. ALL EXPOSED VENEER PLYWOOD AND HARDWOOD

TRIM TO BE CHERRY SPECIES WITH A STAINED FINISH

TO MATCH EXISTING MILLWORK AND TRIM IN

COURTHOUSE.

2. ALL SECURITY EQUIPMENT SHOWN IN 1ST FLOOR

LOBBY IS BY OWNER. GC TO PROVIDE POWER AND

DATA AS SHOWN.

3. WALLS IN THE VICINITY OF NEW WORK TO BE

PATCHED & PAINTED AS REQUIRED - MATCH EXISTING

PAINT COLOR(S).

DEMO WALLS &

DOORS (SHOWN

DASHED)

DEMO RESTROOM

INCLUDING PLUMBING

FIXTURES, CABINETS,

FINISHES, ETC.

DEMO EXIST

FLOOR FINISH

& BASE IN

ENTIRE RM

A70113

INFILL STUD WALL

W/ 5/8" GWB -

MATCH

THICKNESS OF

EXISTING

NEW PLAM

KITCHENETTE

WITH BASE

CAB'TS & UPPERS

NEW UC REFRIG

EXISTING WALL

FINISHES &

GRAPHICS TO

REMAIN (TYP UNO)

R E

P A

IN

U

T H

E R

N W

A L L

EXISTING DOOR

TO REMAIN

EXISTING DOOR

TO REMAIN

NEW DOOR

NEW

UNDERMOUNT

SINK & FAUCET -

SEE PLMG

1-180

312 SF

LOUNGE

1-180

RELOCATE

EXISTING TV TO

THIS LOCATION

NEW FLR

FINISH & BASE -

SEE SCHED

PATCH/INFILL ACT

CEILING IN THE

HATCHED AREA.

MATCH EXISTING GRID

AND TILE.

NEW LIGHT FIXT -

MATCH EXISITNG

1-180

DATE:

PROJECT NO.:PROJECT NO.:

THIS DRAWING IS AN INSTRUMENT OF SERVICE

AND IS THE PROPERTY OF DASHER HURST

ARCHITECTS, PA. IT SHALL NOT BE

REPRODUCED IN WHOLE OR IN PART WITHOUT

THE EXPRESS WRITTEN PERMISSION OF DASHER

HURST ARCHITECTS, PA.

DASHER HURST

1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8

A R C H I T E C T S

J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4

P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0

F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5

W. W. W. D A S H E R H U R S T . C O M

C O

U R

TH

O

U S E R

E N

O V

A

TI

O N

S

ENLARGED

PLANS &

DEMO - 1ST

FLOOR

05/08/2025

N

O R

A N

G E A

V E G

R E E N

C O

V E S

P R

IN

G

S F L

A401

C

LA

Y C

O U

N

TY

23015

100% DOCUMENTS

STRUCTURAL ENGINEER

GM HILL ENGINEERING

9700 PHILIPS HIGHWAY, SUITE 101

JACKSONVILLE, FL 32256

MEP ENGINEER

POWELL & HINKLE

ENGINEERING, P.A.

1409 KINGSLEY AVENUE, BLDG 12A

ORANGE PARK, FL 32073

1/4" = 1'-0"

ENLARGED PLAN - ENTRY

1/4" = 1'-0"

ENLARGED REFLECTED CEILING PLAN - ENTRY

1/4" = 1'-0"

ENLARGED 1ST FLR DEMO PLAN-LOUNGE

1/4" = 1'-0"

ENLARGED 1ST FLR PLAN - LOUNGE

1/4" = 1'-0"

ENLARGED 1ST FLR REFLECTED CEILING PLAN - LOUNGE

1. GC IS TO COORDINATE WITH THE OWNER REGARDING PURCHASING THROUGH THE COUNTY'S DIRECT PURCHASE PROGRAM.

2. SEE SPECIFICATION 011000 FOR MORE INFORMATION

GENERAL NOTES

APP4 SHREDDER 3

APP3 PRINTER 3

APP2 MICROWAVE 2

APP1 REFRIGERATOR 2

APP3

MAGNETOMETER (WALK-THROUGH

METAL DETECTOR)

1 CEIA USA SMD600 PLUS VERIFY W/ OWNERS SUPPLIED OFFER

APP2 X-RAY MACHINE 1 SMITHS DETECTION HI-SCAN 6040C VERIFY W/ OWNERS SUPPLIED OFFER

APP1 SECURITY SYSTEM 1 EVOLV VERIFY W/ OWNERS SUPPLIED OFFER

ITEM

DESCRIPTION

QUANTIT

Y

MANUFACTURER MODEL # DIMENSIONS FINISH REMARKS

APPLIANCE LEGEND

REVISIONS

# DATE DESCRIPTION

1 06/27/2025 ADDENDUM #1

DATE:

PROJECT NO.:PROJECT NO.:

THIS DRAWING IS AN INSTRUMENT OF SERVICE

AND IS THE PROPERTY OF DASHER HURST

ARCHITECTS, PA. IT SHALL NOT BE

REPRODUCED IN WHOLE OR IN PART WITHOUT

THE EXPRESS WRITTEN PERMISSION OF DASHER

HURST ARCHITECTS, PA.

DASHER HURST

1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8

A R C H I T E C T S

J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4

P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0

F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5

W. W. W. D A S H E R H U R S T . C O M

C O

U R

TH

O

U S E R

E N

O V

A

TI

O N

S

INTERIOR

FINISH

LEGEND

05/08/2025

N

O R

A N

G E A

V E G

R E E N

C O

V E S

P R

IN

G

S F L

A601

C

LA

Y C

O U

N

TY

23015

100% DOCUMENTS

STRUCTURAL ENGINEER

GM HILL ENGINEERING

9700 PHILIPS HIGHWAY, SUITE 101

JACKSONVILLE, FL 32256

MEP ENGINEER

POWELL & HINKLE

ENGINEERING, P.A.

1409 KINGSLEY AVENUE, BLDG 12A

ORANGE PARK, FL 32073

ROOM FINISH SCHEDULE

ROOM # ROOM NAME

FLOOR

BASE MAT'L

TYPICAL

WALL

FINISH

ACCENT WALL FINISHES CEILING

REMARKSFINISH NORTH EAST SOUTH WEST MAT'L FINISH

1ST FLR.

1-002 SECURITY SCREENING REPAIR AS NECESSARY TO MATCH EXISTING

1-003 ENTRY HALL REPAIR AS NECESSARY TO MATCH EXISTING

1-003A SECURITY OFFICE REPAIR AS NECESSARY TO MATCH EXISTING

1-017 CORRIDOR REPAIR AS NECESSARY TO MATCH EXISTING

1-049 COC CIVIL DIV REPAIR AS NECESSARY TO MATCH EXISTING

1-180 LOUNGE LVT1 VB1 ACT1 REPAIR AS NECESSARY TO MATCH EXISTING

2ND FLR.

2-003B PUBLIC CORRIDOR PCT2&3 PCB2 P3 GWB P1 / P2 SEE A102 FOR PATTERNING

2-018 CORRIDOR LVT1 VB1 P4 P8 ACT1

2-018A WAITING AREA LVT1 VB1 P4 ACT1

2-018B ELEV ACCESS LVT1 VB1 P4 ACT1

2-300 LOBBY CPT1 VB1 P4 ACT1

2-301 CORRIDOR CPT1 VB1 P4 ACT1

2-302 DEPOS RM CPT1 VB1 P4 ACT1

2-303 CHILD DEPO RM CPT1 VB1 P4 ACT1

2-304 OFFICE FOR CHILDREN CPT1 VB1 P4 ACT1

2-310 CORRIDOR CPT1 VB1 P4 ACT1 SEE FINISH PLAN FOR LOCATION

2-310A LGL ASST SEE 2-310 CORRIDOR

2-310B LGL ASST SEE 2-310 CORRIDOR

2-310C COPY AREA SEE 2-310 CORRIDOR

2-311 RECEPT CPT1 VB1 P4 ACT1

2-312 OFFICE CPT1 VB1 P4 ACT1

2-313 OFFICE CPT1 VB1 P4 ACT1

2-314 STORAGE CPT1 VB1 P4 ACT1

2-315 FILE ROOM CPT1 VB1 P4 ACT1

2-316 BREAK RM LVT1 VB1 P4 ACT1 SEE ELEV

2-320 CORRIDOR CPT1 VB1 P4 ACT1

2-320A LGL ASST SEE 2-320 CORRIDOR

2-320B LGL ASST SEE 2-320 CORRIDOR

2-320C LGL ASST SEE 2-320 CORRIDOR

2-321 OFFICE CPT1 VB1 P4 ACT1

2-322 OFFICE CPT1 VB1 P4 ACT1

2-323 OFFICE CPT1 VB1 P4 ACT1

2-324 CORRIDOR CPT1 VB1 P4 ACT1 SEE FINISH PLAN FOR LOCATION

2-324A COPY AREA CPT1 VB1 P4 ACT1

2-324B LGL ASST SEE 2-324 CORRIDOR

2-324C LGL ASST SEE 2-324 CORRIDOR

2-324C LGL ASST SEE 2-324 CORRIDOR

2-324D LGL ASST SEE 2-324 CORRIDOR

2-325 OFFICE CPT1 VB1 P4 ACT1

2-326 VICT ADV CPT1 VB1 P4 ACT1

2-327 VICT ADV CPT1 VB1 P4 ACT1

2-328 VICT ADV CPT1 VB1 P4 ACT1

2-330 CORRIDOR CPT1 VB1 P4 ACT1

2-331 OFFICE CPT1 VB1 P4 ACT1

2-332 OFFICE CPT1 VB1 P4 ACT1

2-333 STORAGE CPT1 VB1 P4 ACT1

2-334 MEN RR PCT1 PCB1 P5 WT1 WT1 GWB P7

2-335 JC PCT1 PCB1 P5 ACT1

2-336 WOMENS RR PCT1 PCB1 P5 WT1 WT1 GWB P7

2-340 CORRIDOR CPT1 VB1 P4 ACT1

2-341 EVIDENCE STORAGE CPT1 VB1 P4 GWBR P6

2-342 SERVER CPT1 VB1 P4 ACT1

2-343 OPEN SPACE CPT1 VB1 P4 ACT1 SEE FINISH PLAN FOR LOCATION

2-343A LGL ASST SEE 2-343 OPEN SPACE

2-343B LGL ASST SEE 2-343 OPEN SPACE

2-343C LGL ASST SEE 2-343 OPEN SPACE

2-343D LGL ASST SEE 2-343 OPEN SPACE

2-343E LGL ASST SEE 2-343 OPEN SPACE

2-343F LGL ASST SEE 2-343 OPEN SPACE

2-350 CORRIDOR CPT1 VB1 P4 ACT1

2-350A COPY AREA CPT1 VB1 P4 ACT1

2-351 OFFICE CPT1 VB1 P4 ACT1

2-352 OFFICE CPT1 VB1 P4 ACT1

2-353 DEPT HEAD CPT1 VB1 P4 ACT1

2-354 DEPT HEAD CPT1 VB1 P4 ACT1

2-355 DEPT HEAD CPT1 VB1 P4 ACT1

2-356 DEPT HEAD CPT1 VB1 P4 ACT1

2-357 CONFERENCE CPT1 VB1 P4 ACT1

2-400 FLEX OFFICE CBT1 VB1 P4 ACT1

2-410 CHAMBER CBT1 VB1 P4 ACT1

2-411 JUDGE OFFICE CBT1 VB1 P4 ACT1

2-412 TOILET PCT1 PCB1 P5 WT1 GWB P7

2-413 JUDICIAL ASSISTANT CBT1 VB1 P4 ACT1

2-414 SEMI-PRIV ROOM CBT1 VB1 P4 ACT1

2-420 CHAMBER CBT1 VB1 P4 ACT1

2-421 JUDGE OFFICE CBT1 VB1 P4 ACT1

2-422 TOILET PCT1 PCB1 P5 WT1 GWB P7

2-423 JUDICIAL ASSISTANT CBT1 VB1 P4 ACT1

2-424 SEMI-PRIV ROOM CBT1 VB1 P4 ACT1

MISCELLANEOUS PRODUCTS

PL4 PLASTIC LAMINATE FORMICA TBD TBD MATTE - - COLOR TO MATCH VB1

PL3 PLASTIC LAMINATE FORMICA 928-58 MOUSE MATTE - -

PL2 PLASTIC LAMINATE FORMICA 8843-WR NATURAL ASH MATTE - -

PL1 PLASTIC LAMINATE FORMICA 7759-43 SELECT CHERRY ARTISAN - -

MATCH EXISTING WOOD GRAINED PLASTIC

LAMINATE IN THE EXISTING CLERK OF COURTS

MILLWORK

SS2 SOLID SURFACE CORIAN - - ASH CONCRETE - - - - BREAK ROOM COUNTER

SS1 SOLID SURFACE CORIAN - - LINEN - - - - RESTROOM VANITY & COUNTER TOPS

COUNTERTOPS

DS1 SOLID CORE WOOD DOOR TBD MATCH EXISTING CHERRY - MATCH EXISTING

MATCH

EXISTING

EXISTING UNINSTALLED DOORS AVAILABLE FOR

USE IN SHELL SPACE. CONTRACTOR TO VERIFY

IN PREBID MEETING. MNF: MARSHFIELD

WOOD DOORS

GWBR

GYPSUM WALL BOARD WITH SECURITY

MESH

AMICO

SECURITY MESH, ASM 0.75-9F

MAXIMUM SEURITY, CARBON STEEL

- - - - 0.120” WIDTH FOR EVIDENCE STORAGE CEILING

GWB GYPSUM WALL BOARD - - - - - - - - - -

GRID ARMSTRONG 15/16" TEGULAR WHITE - - - -

ACT1

SUSPENDED CEILING TILE ARMSTRONG 1717 - FINE FISSURED TEGULAR WHITE - - 24X24

CEILINGS

P9 PAINT SHERWIN WILLIAMS - - SW9163 / THIN LIZZE SEMI-GLOSS - - TYPICAL SA & JC DOOR FRAME

P8 PAINT BEHR - - PPU18-16 ELEPHANT SKIN EGGSHELL - - WALL ACCENT COLOR

P7 EPOXY PAINT SHERWIN WILLIAMS - - SW7006 / EXTRA WHITE EGGSHELL - - TYPICAL RR CEILING

P6 PAINT SHERWIN WILLIAMS - - SW7006 / EXTRA WHITE EGGSHELL - - TYPICAL SA CEILING

P5 EPOXY PAINT BEHR - - PPU24-11 GREIGE EGGSHELL - - TYPICAL RR WALL

P4 PAINT BEHR - - PPU24-11 GREIGE EGGSHELL - - TYPICAL WALL

P3 PAINT SHERWIN WILLIAMS - - MATCH EXISTING

MATCH

EXISTING

- - WALL & DOOR FRAME COLORS

P2 PAINT SHERWIN WILLIAMS - - MATCH EXISTING

MATCH

EXISTING

WD TRIM / LOWER GWB CEILING / TYP HM

FRAMES

P1 PAINT SHERWIN WILLIAMS - - MATCH EXISTING

MATCH

EXISTING

- - CEILING

PAINT

GROUT MAPEI - - 5001 ALABASTER - - - -

WT1

GLAZED CERAMIC WALL TILE DALTILE K775 BISCUIT MATTE 4"X4" REST ROOMS

WALL MATERIALS

GROUT MAPEI - - 19 PEAR GRAY - - - -

PCB2

PORCELAIN TILE BASE AMERICAN OLEAN THEORETCIAL IMAGINATIVE GRAY TH97 - - MATCH EXITING

EXISTING PUBLIC CORRIDOR BASE TILE

GROUT MAPEI - - 5107 IRON - - 4" x 24"

PCB1

PORCELAIN TILE BASE AMERICAN OLEAN THEORETCIAL IMAGINATIVE GRAY TH97 - - - -

VB1 VINYL BASE JOHNSONITE 29

MATCH EXISTING 4TH JUDGES

CHAMBERS

- - MATCH EXITING TYPICAL VINYL BASE

BASE

TS3 PCT TO BASE TILE SCHLUTER DILEX-AHK SATIN ANOD ALUM - - - - USE @ RESTROOMS ONLY

TS2 LVT TO CARPET JOHNSONITE REDUCING TRANS CD-49-B TBD - - - - CONFIRM W/ FINISH THICKNESSES

TS1 PCT TO CARPET SCHLUTER SCHIENE SATIN ANOD ALUM - - - - SLOPE UNDERLAMENT @ ALL TRANSITIONS

TRANSITION STRIPS

LVT1 LVT SHAW CONTRACT VINYL THOUGHTFUL 20 MIL 22530 WARMTH - - 24" x 24" TYPICAL LVT FLOOR

GROUT MAPEI - - 19 PEAR GRAY - -

PCT3

PORCELAIN TILE AMERICAN OLEAN THEORETICAL IDEAL BEIGE TH91 - -

24"X24" LIGHT EXISTING PUBLIC CORRIDOR TILE

GROUT MAPEI - - 19 PEAR GRAY - - - -

PCT2

PORCELAIN TILE AMERICAN OLEAN THEORETICAL IMAGINATIVE GRAY TH97 24"X24"

DARK EXISTING PUBLIC CORRIDOR TILE

GROUT MAPEI - - 5107 IRON - - - -

PCT1

MOSAIC TILE AMERICAN OLEAN THEORETICAL IMAGINATIVE GRAY TH97 - - 12" x 24"

BATHROOM TILE

CPT1 CARPET SHAW CONTRACT VAPOR TILE 37530 AIRY - - 18" x 36" TYPICAL CARPET FLOOR

FLOORING

MATERIAL DESCRIPTION MANUFACTURER ITEM / STYLE COLOR FINISH SIZE (LxWxH) REMARKS

INTERIOR

INTERIOR FINISHES LEGEND

REVISIONS

# DATE DESCRIPTION

DATE:

PROJECT NO.:PROJECT NO.:

THIS DRAWING IS AN INSTRUMENT OF SERVICE

AND IS THE PROPERTY OF DASHER HURST

ARCHITECTS, PA. IT SHALL NOT BE

REPRODUCED IN WHOLE OR IN PART WITHOUT

THE EXPRESS WRITTEN PERMISSION OF DASHER

HURST ARCHITECTS, PA.

DASHER HURST

1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8

A R C H I T E C T S

J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4 P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0

F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5 W. W. W. D A S H E R H U R S T . C O M

C O

UR

TH

O

US

E

RE

N O

VA

TI

O N

S

5 N O

RA

NG

E A

VE

, G

RE

EN

C

O

VE

SP

RIN

G S, FL

C

LA

Y C

O

UN

TY

23015

100% DOCUMENTS

STRUCTURAL ENGINEER

GM HILL ENGINEERING

9700 PHILIPS HIGHWAY, SUITE 101

JACKSONVILLE, FL 32256

MEP ENGINEER

POWELL & HINKLE

ENGINEERING, P.A.

1409 KINGSLEY AVENUE, BLDG 12A

ORANGE PARK, FL 32073

REVISIONS

# DATE DESCRIPTION

05/08/2025

E103

PARTIAL 1ST

FLOOR POWER

COMM/FA PLAN

6/27/25 ADDENDUM #1

1 1.4

1.4

2.6

2.6

3.1

3.1

4.1

4.1

4.4

4.4

4.8

4.8

5.2

5.2

5.6

5.6

5.9

5.9

6.8

6.8

7.3

7.3

A

B

C

D

E

F

G

H

2.8

2.8

B.3

DATE:

PROJECT NO.:PROJECT NO.:

THIS DRAWING IS AN INSTRUMENT OF SERVICE

AND IS THE PROPERTY OF DASHER HURST

ARCHITECTS, PA. IT SHALL NOT BE

REPRODUCED IN WHOLE OR IN PART WITHOUT

THE EXPRESS WRITTEN PERMISSION OF DASHER

HURST ARCHITECTS, PA.

DASHER HURST

1 0 2 2 P A R K S T R E E T , S U I T E 2 0 8

A R C H I T E C T S

J A C K S O N V I L L E , F L O R I D A 3 2 2 0 4 P H O N E : 9 0 4 . 4 2 5 . 1 1 9 0

F L L I C E N S E N U M B E R A A 2 6 0 0 2 1 6 5 W. W. W. D A S H E R H U R S T . C O M

C O

UR

TH

O

US

E

RE

N O

VA

TI

O N

S

5 N O

RA

NG

E A

VE

, G

RE

EN

C

O

VE

SP

RIN

G S, FL

C

LA

Y C

O

UN

TY

23015

100% DOCUMENTS

STRUCTURAL ENGINEER

GM HILL ENGINEERING

9700 PHILIPS HIGHWAY, SUITE 101

JACKSONVILLE, FL 32256

MEP ENGINEER

POWELL & HINKLE

ENGINEERING, P.A.

1409 KINGSLEY AVENUE, BLDG 12A

ORANGE PARK, FL 32073

REVISIONS

# DATE DESCRIPTION

05/08/2025

T101

PARTIAL 2ND

FLOOR TELE-

COMM. PLAN

6/27/25 ADDENDUM #1

Sheets
A102 - FLOOR PLAN - 2ND & 4TH FLR
A102B - FINISH FLOOR PLAN - 2ND FLOOR
A102C - FLOOR PLAN - 2ND FLOOR (COLORED)
A401 - ENLARGED PLANS & DEMO - 1ST FLOOR
A601 - INTERIOR FINISH LEGEND
G003 - PARTITION SCHEDULE
G101 - 1ST FLOOR LIFE SAFETY PLAN
G102 - 2ND FLOOR LIFE SAFETY PLAN

File details come from the government source that posted it. Updated .