Add03 SDF Ticketing Improvements 6-23-26.pdf

PDF 5 MB Posted

Attached to
SDF Ticketing Improvements
Solicitation number
7611
Issued by
Jefferson County, Kentucky

About this file

This Addendum Number 3, issued by the Louisville Regional Airport Authority on June 23, 2026, modifies the contract documents for the SDF Ticketing Improvements project (LRAA Project #C25S08) at Louisville Muhammad Ali International Airport in Louisville, Kentucky. The addendum addresses substitution requests for expansion joint systems and provides comprehensive responses to contractor questions regarding project scope, specifications, and requirements. Four substitution requests were evaluated: EDIH (Not Accepted), ELCE (Accepted), ENBW (Accepted), and ELCFC (Not Accepted). The accepted substitutions are for interior ceiling and wall expansion joint systems manufactured by Erie Metal Specialties and Balco/CSW Industrials, featuring aluminum extrusions with elastomeric seals designed to accommodate thermal and seismic movement. The bid opening remains scheduled for June 30, 2026, at 10:00 AM with no changes to timeline or procurement procedures.

The addendum clarifies critical project requirements including prevailing wage exemption (Davis Bacon wages not required), project delivery as a specified completion date contract with liquidated damages of $250,000 per day for Kentucky Derby milestones, and installation of owner-supplied electrical drivers with contractor-procured displays and cabling. Key clarifications address baggage handling operations requiring porters from 3:30 AM to 7:30 PM daily, temporary barrier systems requiring Sound Transmission Class of 21, electric-only equipment requirements due to ventilation constraints, and confirmation that asbestos testing identified no asbestos-containing materials. The contractor bears responsibility for means and methods including debris removal, equipment logistics, and structural determination for reusing existing support headers. No prevailing wage rates, Davis Bacon requirements, Buy America compliance, good faith effort documents, or voluntary alternates are included in this procurement.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADDENDUM NUMBER 3

SDF TICKETING IMPROVEMENTS

LRAA PROJECT #C25S08

LOUISVILLE MUHAMMAD ALI INTERNATIONAL AIRPORT

June 23, 2026

This Addendum Number 3, consisting of Seventy (70) pages, is issued in connection with the above-described Contract Documents. The Louisville Regional Airport Authority, pursuant to provisions contained in said Documents, hereby advises all interested parties that changes have been made to the Contract Documents as follows:

No Change to Bid Opening on June 30, 2026 at 10:00AM

1. Specifications

a. None

2. Drawings

a. None

3. The following substitution requests were considered for: (Attached)

a. EDIH - Not Accepted

b. ELCE – Accepted

c. ENBW – Accepted

d. ELCFC – Not Accepted

4. Contractor’s Questions and Responses are attached.

Attachments:

1. Substitution Requests

2. Contractor’s Questions and Responses

LOUISVILLE REGIONAL AIRPORT AUTHORITY

KYLE HARTLAGE, P.E.

Vice President

Louisville Regional Airport Authority Ticketing Renovation

08 May 2026 Issued for Bid

SUBSTITUTION REQUEST FORM

TO: Alliiance, 400 Clifton Ave., Minneapolis, MN 55403 ATTN: Linda Landry PROJECT: Ticketing Renovation

SPECIFIED ITEM:

Section Page Paragraph Description

The undersigned requests consideration of the following:

PROPOSED

SUBSTITUTION:

(Note: Only one substitution per form.)

Attached description includes product description, specifications, drawings, photographs, performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified.

Attached data also includes a description of changes to the Contract Documents, which the proposed substitution will require for its proper installation.

The undersigned certifies that the following paragraphs, unless modified by attachments, are correct:

1. The proposed substitution does not affect dimensions shown on drawings.

2. The undersigned will pay for changes to the building design, including engineering design, detailing, and construction costs caused by the requested substitution.

3. The proposed substitution will have no adverse effect on the other trades, the construction schedule, or specified warranty requirements.

4. Maintenance and service parts will be locally available for the proposed substitution.

The undersigned further states that the function, appearance, and quality of the proposed substitution are equivalent or superior to the specified item.

Submitted by: For use by the design consultant:

Accepted Accepted as noted

Signature

Firm Not Accepted Received too late

Address By

Title

Date Date

Telephone Fax

Remarks:

Attachments:

Alliiance 01 60 00-1 Substitution Form

EDIH

BALCO HDTH

INTERIOR FLOOR TYPE 3079500 2 2.5

- No Changes - Equal to specified product

Erie Metal Specialties, Inc.

13311 Main Rd. Akron, NY 14001

06/09/2026

716-542-3991

Drawings, Product Data x

Architect (MN)

06-22-26

EDIH Series Flooring System

The EDIH Series is designed for expansion joint openings with the ability to provide a smooth and virtually impact-free transition between opposing floor surfaces in addition to accommodating heavy rolling loads and multi-directional seismic movement. The dual interlocking center slide plates are hinged to allow the system to remain flush with finished floor surface. The interlocking slide plate assembly utilizes three rubber anti-vibration dampers to eliminate any metal-to-metal noise and to resist the infiltration of liquids. The optional rubber gutter in conjunction with optional Polycrete Elastomeric Concrete infill enhances the system’s waterproofing capability.

DETAILS

MATERIAL 6063-T6 Aluminum

FINISH Mill (Slip-Resistant Surface)

MOVEMENT

• Thermal: Horizontal and Vertical

• Seismic: Six-way multi-directional seismic movement MOUNTING Block Out

JOINT SIZE 2 inch to 6 inches

LENGTH 10 Linear Feet

APPLICATION Interior

LOAD Pedestrian & Heavy Equipment

INSTALLATION Floor

OPTIONS Moisture Barrier, Fire

Barrier

FEATURES

DURABLE Accommodates Forklifts and Fork Trucks with solid or pneumatic tires.

ADA COMPLIANT Provides flush no-bump transition for sensitive equipment and hospital gurneys.

COORDINATING CORNERS Available with a corner option for a complete floor solution.

MODELS

Erie Metal Specialties, Inc. Phone: 716-542-3991 Website: www.eriemetal.com13311 Main Road

Akron, NY 14001 E-Mail: sales@eriemetal.com

Interior Joints (Floor)

EDIH Series (floor-to-floor)

1.25” [32]

EDIH... Series Floor-Wall

PRODUCT

EDIH-200

EDIH-300

EDIH-500

EDIH-600

EDIH-400

Joint Opening

Sight Line

Blockout Width

Total Movement

2.00 (52)

3.00 (76)

4.00 (102)

5.00 (127)

6.00 (152) 8.75 (222)

8.75 (222)

6.69 (170)

6.69 (170)

4.00 (102) 3.125 (76)

4.00 (102)

3.50 (89)

4.00 (102)

3.50 (89) 2.250 (57)

2.250 (57)

1.375 (35)

1.375 (35)

0.750 (19)

"Sight Line"

A CSW Industrials Company balcousa.com info@balcousa.com 800.767.0082

T E C H N I C A L D A T A

PRODUCT DESCRIPTION

Interlocking, recessed, all-metal floor expansion joint cover designed for heavy-duty loading with minimal bump.

IDEAL FOR

• Applications where heavy duty loading is anticipated

• Applications with frequent movement

PERFORMANCE

Joint Sizes 1” - 4” (25mm - 102mm)

Movement Capabilities:

Permits unrestrained movement of the joint without disengagement of the cover.

ADA Compliant

Loading Capacities:

For detailed load information, refer to Balco Load Data Sheet, available online. Contact factory for analysis of project-specific load cases.

HDTH-HDTHL

Heavy-Duty Twin Hinge

07 95 00

Rev. 01/23

Per ASTM E1399

SEISMIC WINDTHERMAL

Lateral shear ±1

±1

Expansion/contraction ±25% ±25%

Vertical shearVARIES

Contact factory for details

GURNEY/BED

PEDESTRIAN

SCISSOR LIFT

FLOOR SWEEPER

SLOW VEHICULAR

PASSENGER CART

X-RAY

PALLET JACK

5620lbs Payload

CLASS FL 2 FORKLIFT

3370lbs Payload balcousa.com info@balcousa.com 800.767.0082

MATERIALS

• Aluminum extrusions: 6061-T61, ASTM B221

• Aluminum plate: 5052-H32, ASTM B209

• Standard fasteners provided for assembly and installation

• All surfaces in contact with masonry or concrete will be protected by a factory-applied coating.

ADVANTAGES

• Interlocking design for durability

• Minimal bump

• Serrated extrusions ensure good skid resistance

• Heavy-duty loading

• Visible surface has no gaps

• Easy to clean and maintain

• Avoids dirt accumulation

OPTIONS

• Fire Barrier

• Water Barrier

LIMITATIONS

• Provided in 10’-0” (3048mm) maximum lengths

• Cannot be reset if movement exceeds ±25%

FINISH

Aluminum extrusions: Mill finish

RELATED PRODUCTS

• DFH and DFHL Series

• 7500 Series

ADDITIONAL DOCUMENTATION

• Product details

• Installation instructions

• Maintenance and cleaning

• ASTM E1399

• Warranty

• SDS documentation

• LEED documentation

WARRANTY

Standard Warranty: 1 year Optional Warranty: 5 years with Certified Installer Sample warranty available upon request.

HDTH-HDTHL HEAVY-DUTY TWIN HINGE

2 of 2Rev. 01/23

Erie Metal Specialties, Inc. Phone: 716-542-3991 Website: www.eriemetal.com13311 Main Road

Akron, NY 14001 E-Mail: sales@eriemetal.com

EDIH Series Expansion

Joint (Floor-to-Floor)

"A"

1.25" [32mm]

Total System

Depth

"C" "B"

Adjust blockout depth to receive finished floor material.

Factory Pre-Set Dimension

(Nominal)

Important Read Entire Guide Prior to Installation

Please note that the installation details on the following pages are for standard installations. They are not intended to supercede any specific details or drawings that have been submitted and approved or any as-built condition that differs from those depicted herein. Review every page of this Installation Guide prior to starting your installation. For any non-standard condition or to receive additional installation tips please call or email:

Model Number

Total Movement

Joint Opening “A” Min. Nominal Max.

Factory Pre-set

Blockout “B”

Set Back “C”

EDIH-200 .750 (19) 1.625 (41) 2.00 (51) 2.375 (60) 3.9375 (100) 3.125 (79) 2.750 (70)

EDIH-300 1.375 (35) 2.250 (57) 3.00 (76) 3.625 (92) 6.6875 (170) 4.00 (102) 3.625 (92)

EDIH-400 1.375 (35) 3.250 (83) 4.00 (102) 4.625 (117) 6.6875 (170) 3.50 (89) 3.125 (79)

EDIH-500 2.250 (57) 3.875 (98) 5.00 (127) 6.125 (156) 8.6875 (221) 4.00 (102) 3.625 (92)

EDIH-600 2.250 (57) 4.875 (124) 6.00 (152) 7.125 (181) 8.6875 (221) 3.50 (89) 3.125 (79)

Elevation Adjustment with Structural Leveling Bed:

Website: www.eriemetal.com13311 Main Road

Akron, NY 14001 E-Mail: sales@eriemetal.com

It may be advantageous to form the blockout deeper than the 1.25” (32) system height to allow the EDIH expansion joint system flexibility to be field adjusted to the proper elevation and to accommodate variations in the concrete.

1. When the existing blockout is deeper it is recommended that a structural leveling bed be used to bring the base of the blockout to the proper elevation.

Hint: If necessary, establish a working line to keep the system straight in the event that the throat opening is not straight and parallel.

Consult with the Engineer of Record for a list of acceptable structural repair products. Check with the manufacturer of the repair product to ensure that the products listed uses conform to the requirements of the project.

2. When the blockout size is smaller it shall be made larger by milling or saw cutting. Make multiple saw cuts no greater than 3/8” apart from each other along the length of the joint. Use a chipping hammer to remove the designated concrete. The saw cuts should be deep enough to ensure that the breaks are a minimum of 1-1/2” below the finished surface. Repair the blockout bottom in the same method as described in 3A above.

3. The use of shims (plastic, aluminum, or steel) is NOT allowed to elevate the

EDIH aluminum base frame. A structural leveling bed must be used to provide a full structural foundation under the EDIH aluminum base frame.

1.25" (32)

STEP 1 / Mark Set-Back Working Line & Hole Locations

- Measure set-back location from joint edge.

- Snap working Line.

- Place complete assembly into blockout.

- Mark each hole location.

- Remove assembly and reserve it at each location for final installation.

STEP 2 / Drill Anchor Holes

- Drill a 0.125" pilot hole to a depth of 3.00" [76mm].

- Drill anchor holes at a depth of 3.00" [76mm].

- Vacuum or blow out each anchor hole.

Working Line

3.00"

Critical

Dimension

Stagger 10 Foot Sections

3.00" [76mm]

Offset

Wedge Bolt Drill Bit

Erie Metal Specialties, Inc. Phone: 716-542-3991 Website: www.eriemetal.com13311 Main Road

Akron, NY 14001 E-Mail: sales@eriemetal.com

N

O

N

S

H

R

I

N

K

T

R

U

C

T

U

R

A

S

L

G

R

O

U

T*

STEP 3 / Install System Assembly

- Place Assembly into blockout at each reserved location.

- Remove temporary bracing.

- Line up anchor and base frame holes.

- Attach assembly to concrete blockout using Wedge

Bolts.

STEP 4 / Place Blockout Infill Material

- Mix Non-Shrink Infill Grout as instructed by manufacturer.

- Place Grout into blockout using margin trowel.

- Finish Grout flush with top of blockout.

- Install flooring up to edge of base frame.

Wedge Bolt

Finish Floor

Thickness Offset

* Elastomeric Concrete is recommended for blockout infill material.

Erie Metal Specialties, Inc. Phone: 716-542-3991 Website: www.eriemetal.com13311 Main Road

STEP 5 / Clean Up & Protection

- As soon as placement of Elastomeric Concrete (or Non-Shrink Structural Grout) is complete remove all protection paper and duct tape. Once Elastomeric Concrete (or Non-Shrink Structural

Grout) hardens removal of these items will be difficult.

- After all work is complete, clean exposed surfaces with suitable cleaner that will not harm or attack the concrete finish. Remove all duct tape and protection paper.

- Protect the system and its components during construction. Heavy construction vehicles will not be permitted to cross the expansion joint. Subsequent damage to the expansion joint system will be repaired at the general contractor's expense.

Finished Floor or Temporary Protection

Protect expansion joint finish from construction equipment

Erie Metal Specialties, Inc. Phone: 716-542-3991 Website: www.eriemetal.com13311 Main Road

08 May 2026 Issued for Bid

SUBSTITUTION REQUEST FORM

TO: Alliiance, 400 Clifton Ave., Minneapolis, MN 55403 ATTN: Linda Landry PROJECT: Ticketing Renovation

SPECIFIED ITEM:

Section Page Paragraph Description

The undersigned requests consideration of the following:

PROPOSED

SUBSTITUTION:

(Note: Only one substitution per form.)

Attached description includes product description, specifications, drawings, photographs, performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified.

Attached data also includes a description of changes to the Contract Documents, which the proposed substitution will require for its proper installation.

The undersigned certifies that the following paragraphs, unless modified by attachments, are correct:

1. The proposed substitution does not affect dimensions shown on drawings.

2. The undersigned will pay for changes to the building design, including engineering design, detailing, and construction costs caused by the requested substitution.

3. The proposed substitution will have no adverse effect on the other trades, the construction schedule, or specified warranty requirements.

4. Maintenance and service parts will be locally available for the proposed substitution.

The undersigned further states that the function, appearance, and quality of the proposed substitution are equivalent or superior to the specified item.

Submitted by: For use by the design consultant:

Accepted Accepted as noted

Signature

Firm Not Accepted Received too late

Address By

Title

Date Date

Telephone Fax

Remarks:

Attachments:

Alliiance 01 60 00-1 Substitution Form

079500 2 2.5

- No Changes - Equal to specified product

Erie Metal Specialties, Inc.

13311 Main Rd. Akron, NY 14001

06/09/2026

716-542-3991

Drawings, Product Data

ELCE

INTERIOR CEILING TYPE 2

BALCO ACWW/ACWC

x

ELCE Series - Ceiling System

Website: www.eriemetal.com13311 Main Road

Akron, NY 14001 E-Mail: sales@eriemetal.com

• Thermal: Horizontal & Vertical

• Seismic: Lateral Shear

MOUNTING Flush JOINT SIZE 2 to 6 inches SEAL LENGTH Continuous APPLICATION Interior INSTALLATION Ceiling

FEATURES

MAXIMUM MOVEMENT "V" seal design allows for maximum thermal and seismic movement

ACOUSTIC CEILING Fully integrated with suspended ceiling grid system.

DETAILS

MATERIAL

6063-T6 Aluminum, Meets ASTM B209 FINISH Mill

MOVEMENT

Interior Joints (C eiling)

*For actual seal colors, please contact EMS for a seal sample

Sizes 2"-4":

Sizes 5"+:

T E

C H

N

IC

A L

D A

T A balcousa.com Toll Free: 1-800-767-0082 email: info@balcousa.com

A CSW Industrials Company

PRODUCT DESCRIPTION

Balco interior face seal expansion joint covers are a combination of elastomeric seals and aluminum base frames that are designed to mechanically attach to various wall and ceiling materials such as gyp-board, CMU or acoustical ceiling frame-work.

IDEAL FOR

Applications where a narrow, recessed and colorable joint cover is preferred for blending with interior finishes

PERFORMANCE

Joint Sizes 2” - 36” (51mm - 914mm) Movement Capabilities:

Permits unrestrained movement of the joint without damage to the seal.

MATERIALS

• Aluminum extrusions: 6063-T5, ASTM B221

• Elastomeric Seals: 65 shore A durometer Santoprene

• Standard fasteners provided for assembly and installation

• All surfaces in contact with masonry or concrete will be protected by a factory-applied coating.

ADVANTAGES

• Narrow sight-line

• No exposed fasteners

• Available in multiple standard colors

• Custom colors available**

OPTIONS

• Fire barrier

LIMITATIONS

• Joint sides must be smooth for proper water tight installation

• Provided in 10’-0” (3048mm) maximum lengths

FINISH

Standard

• Mill finish concealed aluminum

• Architectural class II clear anodized exposed flanges (TCWWE and TCVSE)

• Seal available in black, gray, tan, white, and bronze Optional**

• Custom seal covers

• Color anodized exposed aluminum (TCWWE and TCVSE only)

*Shear movement requires specific accommodations at wall terminations, contact factory for details.

Shear values are for wall installation; ceiling is opposite **Extended lead times and additional costs may apply

Lateral shear (Joint sizes 1” - 5”)*±5 0%

±1

Expansion/contraction±100% ±50%

Vertical shear* Contact factory for details

VARIES

Interior Santoprene Face Seal Expansion Joint Covers

Rev. 04/22 balcousa.com email: info@balcousa.com Toll Free: 1-800-767-0082

System Application TCWW Interior face seal with 50% expansion & contraction

TCVS

TCWWE

TCVSE

Interior face seal with 100% expansion & contraction

Interior face seal with 50% expansion & contraction and surface mounted flange for corner conditions up to 4” (102mm) joint width Interior face seal with 100% expansion & contraction and surface mounted flange for corner conditions up to 4” (102mm) joint width

System Application GCWW Interior face seal with 50% expansion and contraction, for gyp-board wall or ceil-ing with flanges concealed by mud and tape

GCVS

GCWC

GCVSC

Interior face seal with 100% expansion and contraction, for gyp-board wall or ceil-ing with flanges concealed by mud and tape Interior corner face seal with 50% expansion and contraction, for gyp-board wall or ceiling with flanges concealed by mud and tape Interior corner face seal with 100% expansion and contraction, for gyp-board wall or ceiling with flanges concealed by mud and tape

INTERIOR FACE SEAL MODEL GUIDE

TCTC

ACWW Interior acoustical ceiling face seal with 50% expansion and contraction

ACVS

ACWC

ACVSC

Interior acoustical ceiling face seal with 100% expansion and contraction

Interior corner acoustical ceiling face seal with 50% expansion and contraction

Interior corner acoustical ceiling face seal with 100% expansion and contraction

RELATED PRODUCTS

• Interior silicone face seals

• Rizza premium silicone face seals

ADDITIONAL DOCUMENTATION

• Product details

• Installation instructions

• Maintenance and cleaning

• ASTM E1399

• Warranty

• MSDS documentation

• LEED documentation

WARRANTY

Standard Warranty: 5 years Sample warranty available upon request.

Interior Santoprene Face Seal Expansion Joint Covers

INTERIOR FACE SEAL MODEL GUIDE

G

ELCE-Series Installation Instructions

Erie Metal Specialties, Inc. | 13311 Main Rd., Akron, NY 14001 | (716) 542-3991 | sales@eriemetal.com

SEISMIC ELASTOMERIC CORRIDOR CEILING SYSTEM –

ACOUSTICAL TILE APPLICATION

MODEL(S): ELCE/ELCEW

ELCE Ceiling to Ceiling Cover System

GENERAL DESCRIPTION

The ELCE Seismic Elastomeric Ceiling System uses an aluminum channel attached to the grid system above the sight line. The finished elastomeric seal comes in four colors to match the surrounding substrate and finish material. This system accommodates seismic movement.

Introduction + Safety

Please read the complete instructions carefully before beginning any work. To ensure proper installation and performance of the product, the following actions must be completed by the installing contractor. Failure to do so will affect the product warranty.

Transportation + Storage o Inspect all shipments and materials for missing or damaged components and hardware.

o Material must be stored in a clean, dry location.

Preparation

• Locate the packing slip(s) and shop drawings.

• Verify that all products listed on the packing slip are included in the package.

• Check the products for damage. If products are damaged, report a freight claim immediately and leave the products in their packaging. If you sign for products without reporting damage, you waive your right to a freight claim and will be responsible for their replacement cost.

• Read the instructions thoroughly before beginning installation.

GENERAL SAFETY PRECAUTIONS Improper selection, installation, or use can cause personal injury or property damage. It is solely the responsibility of the user, through their own analysis, to select products suitable to the specific application requirements, ensure proper maintenance and use as intended. Follow local, state, and federal regulations for proper installation and operation requirements.

SEISMIC ELASTOMERIC CEILING SYSTEM

Model(s): ELCE/ELCEw

Erie Metal Specialties, Inc. | 13311 Main Rd., Akron, NY 14001 | (716) 542-3991 | sales@eriemetal.com

Tool List

• Tape measure

• Chop saw to cut product to length

• Drill for installing fasteners

• Utility knife

Included with the expansion joint system:

#6 x ½” Sheet metal screw

Preinstallation

1. Inspect that the ceiling system was properly constructed and the joint opening matches what is required by the shop drawings.

2. Remove ceiling grid on both sides of the joint opening to ease installation.

INSTALLATION

1. Position aluminum extrusions on the inside lip of the “T” grid as shown and attach with #6 self-drilling screws (included) 18” on center. See Figure 1.

Model(s): ELCE/ELCEw

Erie Metal Specialties, Inc. | 13311 Main Rd., Akron, NY 14001 | (716) 542-3991 | sales@eriemetal.com

2. Position the elastomeric seal into position and push the seal bulbs into the extrusion channels as shown. Make sure you hold the “T” grid securely and seat the bulbs all the way into the channel. Do not stretch the seal lengthwise during installation. See Figure 2.

3. Replace the ceiling tile on both sides of the joint opening. See Figure 3.

Model(s): ELCE/ELCEw

Erie Metal Specialties, Inc. | 13311 Main Rd., Akron, NY 14001 | (716) 542-3991 | sales@eriemetal.com

ELCEw Ceiling to Corner Cover System

The ELCEw Seismic Elastomeric Ceiling System uses an aluminum channel attached to the grid system above the sight line. The finished elastomeric seal comes in four colors to match your surrounding substrate and finish material. This system accommodates seismic movement.

INSTALLATION

1. Position aluminum extrusion on the inside lip of the “T” grid as shown and attach with #6 self-drilling screws (included) 18” on center. On the wall side, position the corner extrusion so the extrusion channels are level with each other. Fasten with anchors (by installer) into the structural support. See Figure 1.

Model(s): ELCE/ELCEw

Erie Metal Specialties, Inc. | 13311 Main Rd., Akron, NY 14001 | (716) 542-3991 | sales@eriemetal.com

2. Position the elastomeric seal into position and push the seal bulbs into the extrusion channels as shown. Make sure you hold the “T” grid securely and seat the bulbs all the way into the channel. Do not stretch the seal lengthwise during installation. See Figure 2.

3. Replace the ceiling tile on the non-wall side of the joint opening. See Figure 3.

Model(s): ELCE/ELCEw

Erie Metal Specialties, Inc. | 13311 Main Rd., Akron, NY 14001 | (716) 542-3991 | sales@eriemetal.com

FIELD SPLICE FOR ELASTOMERIC V-SEAL

1. After determining the angle needed, use a miter box and a non-serrated saw (teeth removed) and cut ends of seal clean, straight and square. See Figure 1

2. After donning the proper PPE, use a solvent (by others) that is safe for elastomeric materials and clean any residual material from the cut ends of the seals. Allow to dry prior to Step #3.

See Figure 2

Straight Butt Splice

Insert splice clips (if required) (part # 27511) halfway into the alignment holes on one of the seals. Apply glue, cyanoacrylate or similar adhesive (by others) to both seal ends and follow instructions by the adhesive manufacturer. Almost immediately after adhesive is applied, insert the protruding ends of the splice clips into the ends of the two seals together, applying uniform pressure for at least two minutes while maintaining contact between both sides. The splice clip is not necessary, but is recommended, especially on larger sized seals. See Figure 3

Figure 1

Figure 2

Figure 3

Model(s): ELCE/ELCEw

Erie Metal Specialties, Inc. | 13311 Main Rd., Akron, NY 14001 | (716) 542-3991 | sales@eriemetal.com

Vertical Outside Splice

Insert splice clips (if required) (part # 28090) halfway into the alignment holes on one of the seals. Apply glue, cyanoacrylate or similar adhesive (by others) to both seal ends and follow instructions by the adhesive manufacturer. Almost immediately after adhesive is applied, insert the protruding ends of the splice clips into the ends of the two seals together, applying uniform pressure for at least two minutes while maintaining contact between both sides. The splice clip is not necessary, but is recommended, especially on larger sized seals. See Figure 4

Vertical Inside Splice

Insert splice clips (if required) (part # 28090) halfway into the alignment holes on one of the seals. Apply glue, cyanoacrylate or similar adhesive (by others) to both seal ends and follow instructions by the adhesive manufacturer. Almost immediately after adhesive is applied, insert the protruding ends of the splice clips into the ends of the two seals together, applying uniform pressure for at least two minutes while maintaining contact between both sides. The splice clip is not necessary, but is recommended, especially on larger sized seals. See Figure 5

Figure 4

Figure 5

Model(s): ELCE/ELCEw

Erie Metal Specialties, Inc. | 13311 Main Rd., Akron, NY 14001 | (716) 542-3991 | sales@eriemetal.com

Horizontal Splice

Insert splice clips (if required) (part #

28091) halfway into the alignment holes on one of the seals. Apply glue, cyanoacrylate or similar adhesive (by others) to both seal ends and follow instructions by the adhesive manufacturer. Almost immediately after adhesive is applied, insert the protruding ends of the splice clips into the ends of the two seals together, applying uniform pressure for at least two minutes while maintaining contact between both sides.

The splice clip is not necessary, but is recommended, especially on larger sized seals. See

Figure 6

3. Recheck the splices after the adhesive has cured and reapply adhesive as necessary. Allow 15 minutes prior to installation of seal. Allow 24 hours for adhesive to fully cure and achieve proper working strength. Ensure that the splice of the seal is not within 2” of a joint in the aluminum extrusion, if possible.

See Figure 7

Figure 6

Figure 7

07 95 13-1

Erie Metal Specialties, Inc.

13311 Main Road Akron, NY 14001 Phone: 716-542-3991 Fax: 716-542-3996 E-mail: sales@eriemetal.com Website: www.eriemetal.com

SPECIFICATION

Section 07 95 13

Erie Metal Specialties, Interior Architectural Systems

Model(s) ELCD, ELCE, ELCA, ELCH Series for Wall, Soffit and Ceiling

Interior Seismic Expansion Control System

PART 1 – GENERAL

1.01 Work Included

A. The work shall consist of furnishing and installing expansion joints in accordance with the details shown on the plans and the requirements of the specifications. The joints are proprietary designs utilizing extruded elastomeric seals and aluminum profiles.

B. Related Work

- Miscellaneous and ornamental metals

- Sealants and caulking

- Interior Finishes

1.02 Submittals

A. Template Drawings - Submit typical expansion joint cross-section(s) indicating pertinent dimensioning, general construction, component connections, and anchorage methods.

1.03 Product Delivery, Storage and Handling

A. Deliver products in each manufacturer's original, intact, labeled containers and store under cover in a dry location until installed. Store off the ground, protect from weather and construction activities.

1.04 Acceptable Manufacturer

A. All joints shall be supplied by; Erie Metal Specialties, Inc. • 13311 Main Road • Akron • New York • 14001 • Phone (716) 542-3991 • Fax (716) 542-3996 • sales@eriemetal.com • www.eriemetal.com .

B. Alternate manufacturers and their products will be considered, provided they meet the design concept and are produced of materials that are equal to or superior to those called for in the base product specification.

C. Any proposed alternate systems must be submitted and receive approval 21 days prior to the bid. All post bid submittals will not be considered. This submission shall be in accordance with MATERIALS

AND SUBSTITUTIONS.

mailto:sales@eriemetal.com http://www.eriemetal.com/ mailto:sales@eriemetal.com http://www.eriemetal.com/

07 95 13-2

13311 Main Road Akron, NY 14001 Phone: 716-542-3991 Fax: 716-542-3996 E-mail: sales@eriemetal.com Website: www.eriemetal.com

- Any manufacturer wishing to submit for prior approval must provide the following:

1. A working 6” sample of the proposed system with a letter describing how system is considered superior to the specified system.

2. A project proposal drawing that illustrates the recommended alternate system installed in the wall or ceiling construction that is specific to the project. Typical catalog cut sections will not be considered.

3. Verifiable list of prior installations showing prior and successful experience with the proposed systems.

4. Any substitution products not adhering to all specification requirements within, will not be considered.

1.05 Quality Assurance

A. Warranty: The expansion control system’s performance shall be warranted for a period of 1 year.

Installation shall be in strict accordance with manufacturer’s technical specifications, details, installation instructions and general procedures in effect for normal intended usage and suitable applications under specified design movements and loading conditions.

B. Manufacturer: Shall have a minimum ten (10) years experience specializing in the design and manufacture of Architectural Expansion Control Systems.

C. Maintenance: The manufacturer shall provide the owner-operator a preventive maintenance guideline for Expansion Control Systems.

PART 2 - PRODUCT

2.01 General

A. Provide interior wall and ceiling expansion joint system that incorporates specially engineered elastomeric colorable profiles to facilitate multi-directional seismic movement without stress to adjacent components. Design system to be easily installed and surface mounted to traditional drywall construction utilizing drywall screws. Aluminum extrusions shall be designed with mounting flanges exhibiting factory pre-punched holes properly sized and spaced to receive joint compound.

For walls, soffits and ceilings furnish Erie Metal Specialties, Model “ELCA", "ELCD", "ELCE", "ELCH” Expansion Control System as indicated on drawings.

07 95 13-3

13311 Main Road Akron, NY 14001 Phone: 716-542-3991 Fax: 716-542-3996 E-mail: sales@eriemetal.com Website: www.eriemetal.com

2.02 Components and Materials

A. Aluminum Extrusions - Material to conform to properties of ASTM B221, alloy 6063-T5. Profile shall be lightweight and capable of accommodating various wall and ceiling conditions. Design profile with semi-closed extrusion cavity and features that will provide a mechanical lock for the Elastomeric Seal.

B. Aluminum Shapes - Material to conform to ASTM B209, alloy 6061-T6 or 5005-H34.

C. Elastomeric Seals - Material shall be a flexible extruded Santoprene or manufacturer’s alternate material exhibiting a shore A hardness of 64 +/-5 with U.V. stabilizer. The seal shall be a multi-cellular profile with side lugs that mechanically snap lock into a corresponding extrusion cavity without assistance from fasteners for a secure fit.

D. Anchors - Secure aluminum extrusion(s) by utilizing standard drywall screws for gypsum wall board construction. Screws are supplied by others and shall be of proper length to secure aluminum extrusion. Locate screws within solid metal between factory pre-punched flange holes.

Anchor spacing shall be 24” o.c. maximum.

E. Accessories - Provide necessary and related parts required for complete installation.

2.03 Fabrication

A. Aluminum extrusions shall be supplied in 10 ft. lengths. The contractor shall be responsible for field cutting the extrusion to obtain the proper joint profile. All cutting and mitering of the seal required at directional changes shall be performed by the contractor in a neat and workmanlike manner utilizing manufacturers recommended splice clips and adhesive.

C. All anchor holes shall be field drilled in accordance with manufacturer’s drawings. Spacing shall be a maximum of 24” o.c.

2.04 Finishes

A. Aluminum extrusions shall be supplied in standard mill finish.

B. Elastomeric seals shall be supplied in standard colors - Black, beige, and gray.

Optional custom colors available

PART 3 - EXECUTION

3.01 Installation

A. Protect all expansion joint component parts from damage during installation and thereafter until completion of structure.

07 95 13-4

13311 Main Road Akron, NY 14001 Phone: 716-542-3991 Fax: 716-542-3996 E-mail: sales@eriemetal.com Website: www.eriemetal.com

B. Expansion joint systems shall be installed in strict accordance with the manufacturer's typical details and instructions along with the advice of their qualified representative.

C. Contractor shall provide proper and adequate adjacent construction to receive and support the expansion control joint system. The supporting framework (studding) shall be of design to secure all threaded hardware and provide rigidity for the proper installation and function of the joint system.

3.02 Clean and Protect

A. Protect system and its components during construction. After work is complete in adjacent areas clean exposed surfaces with a suitable cleaner that will not harm or attack the elastomeric material.

NO. Description Date By The information contained herein is the proprietary property of ERIE METAL SPECIALTIES, INC. No portion of it may be reproduced by any means or used in any form accept for the purpose for which it was intended. All rights of design and invention are hereby reserved.

PROJECT:

TITLE:

13311 Main Road * Akron * New York * 14001 Phone: (716) 542-3991 * Fax: (716) 542-3996 * E-mail: sales@eriemetal.com

Detailed by:

Checked by:

Scale:

Sheet No.: Drawing No.:

EMS Job #:

Date:

Date:

NTS

SLP

BAF

10/21/17

10/21/17

ELCE-1

PRODUCT Application Joint Size "A" @ Mean T°F

Total Movement

IN (MM)

Exposed Site line: IN(MM)

ELCE-200 Ceiling 2.00" (51) 2.00" (51) 2.00" (51)

ELCE-200/200W

ELCE-200W Ceiling Corner

SEAL COLOR SELECTOR

BLACK _____ WHITE _____

BEIGE _____ GRAY _____

"A"

INTERIOR SUSPENDED FLAT/CORNER CEILING SYS.

MOVEMENT: +/- 50% NOMINAL JOINT WIDTH

STOCK LENGTHS: ALUMINUM FRAMES: 10'

SEAL: CONTINUOUS

SUSPENDED CEILING

SYS. (BY OTHERS)

ALUMINUM

FRAME

#6X1/2 SMS 31819

@ 18" O.C.

CEILING TEE'S

(BY OTHERS)

SANTOPRENE FACE SEAL

(SELECT COLOR)

"A"

SUSPENDED CEILING

SYS. (BY OTHERS)

ALUMINUM FRAME

#6X1/2 SMS 31819

@ 18" O.C.

3/16" DIA. HH DRYWALL

OR MASONRY ANCHOR

AS REQ'D. @ 18" O.C.

(BY INSTALLER)

SANTOPRENE FACE SEAL

(SELECT COLOR)

2.00" (51) 2.00" (51) 2.00" (51)

ERIE METAL SPECIALTIES, INC. No portion of it may be reproduced by any means or used in any form accept for the purpose for which it was intended. All rights of design and invention are hereby reserved.

PROJECT:

TITLE:

13311 Main Road * Akron * New York * 14001 Phone: (716) 542-3991 * Fax: (716) 542-3996 * E-mail: sales@eriemetal.com

Detailed by:

Checked by:

Scale:

Sheet No.: Drawing No.:

EMS Job #:

Date:

Date:

NTS

SLP

BAF

10/21/17

10/21/17

ELCE-1

PRODUCT Application Joint Size "A" @ Mean T°F

Total Movement

IN (MM)

Exposed Site line: IN(MM)

ELCE-300 Ceiling 3.00" (76)

ELCE-300/300W - 600/600W

ELCE-600W Ceiling Corner

SEAL COLOR SELECTOR

BLACK _____ WHITE _____

BEIGE _____ GRAY _____

INTERIOR SUSPENDED FLAT/CORNER CEILING SYS.

MOVEMENT: +/- 50% NOMINAL JOINT WIDTH

STOCK LENGTHS: ALUMINUM FRAMES: 10'

SEAL: CONTINUOUS

"A"

ALUMINUM

FRAME

CEILING TEE'S

(BY OTHERS)

SANTOPRENE FACE SEAL

(SELECT COLOR)

#6X1/2 SMS 31819

@ 18" O.C. "A"

SUSPENDED

CEILING SYS.

(BY OTHERS)

3/16" DIA. HH DRYWALL

OR MASONRY ANCHOR

AS REQ'D. @ 18" O.C.

(BY INSTALLER)

ALUMINUM

FRAME#6X1/2 SMS 31819

@ 18" O.C.

ELCE-400 Ceiling 4.00" (102)

ELCE-500 Ceiling 5.00" (127)

ELCE-600 Ceiling 6.00" (152)

ELCE-500W Ceiling Corner

ELCE-400W Ceiling Corner

ELCE-300W Ceiling Corner

3.00" (76)

4.00" (102)

5.00" (127)

6.00" (152)

3.00" (76)

4.00" (102)

5.00" (127)

6.00" (152)

3.00" (76)

4.00" (102)

5.00" (127)

6.00" (152)

3.00" (76)

4.00" (102)

5.00" (127)

6.00" (152)

3.00" (76)

4.00" (102)

5.00" (127)

6.00" (152)

08 May 2026 Issued for Bid

SUBSTITUTION REQUEST FORM

TO: Alliiance, 400 Clifton Ave., Minneapolis, MN 55403 ATTN: Linda Landry PROJECT: Ticketing Renovation

SPECIFIED ITEM:

Section Page Paragraph Description

The undersigned requests consideration of the following:

PROPOSED

SUBSTITUTION:

(Note: Only one substitution per form.)

Attached description includes product description, specifications, drawings, photographs, performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified.

Attached data also includes a description of changes to the Contract Documents, which the proposed substitution will require for its proper installation.

The undersigned certifies that the following paragraphs, unless modified by attachments, are correct:

1. The proposed substitution does not affect dimensions shown on drawings.

2. The undersigned will pay for changes to the building design, including engineering design, detailing, and construction costs caused by the requested substitution.

3. The proposed substitution will have no adverse effect on the other trades, the construction schedule, or specified warranty requirements.

4. Maintenance and service parts will be locally available for the proposed substitution.

The undersigned further states that the function, appearance, and quality of the proposed substitution are equivalent or superior to the specified item.

Submitted by: For use by the design consultant:

Accepted Accepted as noted

Signature

Firm Not Accepted Received too late

Address By

Title

Date Date

Telephone Fax

Remarks:

Attachments:

Alliiance 01 60 00-1 Substitution Form

079500 2 2.5

- No Changes - Equal to specified product

Erie Metal Specialties, Inc.

13311 Main Rd. Akron, NY 14001

06/09/2026

716-542-3991

Drawings, Product Data

ELCFC

INTERIOR FLOOR TYPE 4

BALCO 75FCE

x

• Thermal: Horizontal

MOUNTING Surface

JOINT SIZE 1 inch or 2 inches

LENGTH 10 Linear Feet

LOAD Pedestrian and Light Cart

INSTALLATION Floor

OPTIONS Seal Color, Moisture Barrier, Fire

Barrier

This Flooring Infill Elastomeric Expansion Joint System is a surface mounted system that is designed for mounting directly over the expansion joint and receives flooring on top of the installed assembly.

FEATURES

COORDINATING CORNERS Available with corner option for a complete floor solution.

CONTINUOUS SIGHT LINE Available with coordinating wall and ceiling systems to provide an aesthetically pleasing appearance.

COMPLEMENTARY SEAL COLORS Available in four elastomeric seal color options: beige, white, gray or black.

DETAILS

MATERIAL 6063-T6 Aluminum FINISH Mill and Rubber Seal

MOVEMENT

MODELS

SEAL COLORS

Beige GrayWhite Black

Erie Metal Specialties, Inc. Phone: 716-542-3991 13311 Main Road Website: www.eriemetal.com Akron, NY 14001 E-Mail: sales@eriemetal.com

ELCFC Series Floor System

Interior Joints (Floor) Floor-to-Wall/CornerFloor-to-Floor

MODEL INSTALLATION JOINT SIZE

AT MEAN T°F SYSTEM WIDTH TOTAL

MOVEMENT

ELCFC-100 Floor-to-Floor 1" (25mm) 1" (25mm) 0.5" (13mm)

ELCFC-100W Floor-to-Wall 1" (25mm) 1" (25mm) 0.5" (13mm)

ELCFC-200 Floor-to-Floor 2" (51mm) 2" (51mm) 1" (25mm)

ELCFC-200W Floor-to-Wall 2" (51mm) 2" (51mm) 1" (25mm)

C H

N

IC

A L

D A

T A balcousa.com Toll Free: 1-800-767-0082 email: info@balcousa.com

A CSW Industrials Company

PRODUCT DESCRIPTION

Elastomeric seal with aluminum base frames for floor expansion joint applications that minimizes sight-line and blends in with surrounding floor finishes

IDEAL FOR

• Smaller expansion joint openings where colors are preferred to blend with floor finishes

• Applications where a narrow sight-line is preferred

• Floors with carpet or VCT

• Floors with thick finishes such as ceramic tile, marble, granite, or pavers

PERFORMANCE

Joint Sizes 1” - 2” (25mm - 51mm) Loading

For detailed load information, refer to Balco Load Data Sheet, available online. Contact factory for analysis of project-specific load cases.

Movement Capabilities:

Permits unrestrained movement of the joint without disengagement of the cover.

ADA Compliant

MATERIALS

• Aluminum extrusions: 6063-T5, ASTM B221

• Elastomeric Seals: 65 shore A durometer Santoprene or TPR

• Standard fasteners provided for assembly and installation

• All surfaces in contact with masonry or concrete will be protected by a factory-applied coating.

ADVANTAGES

• Narrow sight-line

• Available in multiple standard colors

OPTIONS

• Fire barrier

LIMITATIONS

• Provided in 10’-0” (3048mm) maximum lengths

• Only black seals are UV resistant (For exterior use)

FINISH

• Mill finish aluminum

• Seal available in black, gray, tan, white, and bronze Optional*

• Custom seal colors

*Extended lead times and additional costs may apply

Pedestrian

Expansion/contraction±25%

Per ASTM E1399

THERMAL

7500 Series Floor Expansion Joint Covers

Rev. 06/20 balcousa.com email: info@balcousa.com

RELATED PRODUCTS

• 7500 series wall covers

ADDITIONAL DOCUMENTATION

• Product details

• Installation instructions

• Maintenance and cleaning

• ASTM E1399

• Warranty

• MSDS documentation

• LEED documentation

WARRANTY

Standard Warranty: 5 years Sample warranty available upon request.

System Application 75FCE Interior floor to floor with flanges concealed by carpet

75FP Interior floor to floor with recess mount for thick floor finishes such as ceramic tile, marble, granite, or pavers

75FPE Interior surface mounted floor to floor

75FTE Interor surface mounted floor to floor with flush fit to adjacent VCT floor finish

75FVCE Interior floor with flange concealed by carpet to surface mounted wall

75FVP Interior floor with recess mount for thick floor finishes such as ceramic tile, marble, granite, or pavers to surface mounted wall

75FVPE Surface mounted floor to surface mounted wall

75FVP-E Interior floor with recess mount for thick floor finishes such as ceramic tile, marble, granite, or pavers to existing wall

75FVTE Interor surface mounted floor with flush fit to adjacent VCT floor finish to surface mounted wall

7500 FLOOR MODEL GUIDE

7500 Series Floor Expansion Joint Covers

Website: www.eriemetal.com13311 Main Road

Akron, NY 14001 E-Mail: sales@eriemetal.com

Seal Flooring - Standard Series Model(s) "ELCFC-100/200" & "ELCFC-100W/200W"

Horizontal Expansion Control Systems

(for ELCFC-100/100W)

(for ELCFC-100W)

(for ELCFC-200/200W)

(for ELCFC-200W) (for ELCFC-200/200W)

ELCFC-100/100W

ELCFC-100/100W

ELCFC-200/200W

ELCFC-200/200W

1" - ELCFC-100

2" - ELCFC-200

(ELCFC-200/200W only)

ELCFC-100 BILL OF MATERIALS (BOM)

ELCFC-100 BOM

RAIL 1 RAIL 2 SEAL (COLOR) ANCHOR

ELCFC(R)-100 ELCFC(R)-100 ELC(FL)-100BG (BEIGE)

ELC(FL)-100BL (BLACK)

ELC(FL)-100GR (GRAY)

ELC(FL)-100WH (WHITE)

NONE

PROVIDED BY

CONTRACTOR

ELC(FL)-100XX

SPECIFY COLOR

ANCHOR PROVIDED

BY CONTRACTOR

ELCFC(R)-100 (x2)

ELCFC-100W BILL OF MATERIALS (BOM)

ELCFS-100W BOM

RAIL 1 RAIL 2 SEAL (COLOR) ANCHOR

ELCFC(R)-100 ELCF(RFWC) ELC(FL)-100BG (BEIGE)

ELC(FL)-100BL (BLACK)

ELC(FL)-100GR (GRAY)

ELC(FL)-100WH (WHITE)

NONE

PROVIDED BY

CONTRACTOR

ELC(FL)-100XX

SPECIFY COLOR

ANCHOR PROVIDED

BY CONTRACTOR

ELCFC(R)-100

ELCF(RFWC)-100

ANCHOR PROVIDED

ELCFC-200 BILL OF MATERIALS (BOM)

ELCFS-200 BOM

RAIL 1 RAIL 2 RAIL 3 SEAL (COLOR) ANCHOR

ELCFC(R)-200 ELCFC(R)-200 ELCF-SUP ELC(FL)-100BG (BEIGE)

ELC(FL)-100BL (BLACK)

ELC(FL)-100GR (GRAY)

ELC(FL)-100WH (WHITE)

NONE

PROVIDED BY

CONTRACTOR

ELC(FL)-200XX

SPECIFY COLOR

ANCHOR PROVIDED

BY CONTRACTOR

ELCFC(R)-200 (x2)

ELCF-SUP

ELCFC-200W BILL OF MATERIALS (BOM)

ELCFS-200W BOM

RAIL 1 RAIL 2 RAIL 3 SEAL (COLOR) ANCHOR

ELCFC(R)-200 ELCF(RFW)-200 ELCF-SUP ELC(FL)-100BG (BEIGE)

ELC(FL)-100BL (BLACK)

ELC(FL)-100GR (GRAY)

ELC(FL)-100WH (WHITE)

NONE

PROVIDED BY

CONTRACTOR

ELC(FL)-200XX

SPECIFY COLOR

ANCHOR PROVIDED

BY CONTRACTOR

ELCF(RFW)-200

ELCF-SUP

ELCFC(R)-200

ANCHOR PROVIDED

PROJECT:

TITLE:

13311 Main Road • Akron • New York • 14001 Phone: (716) 542-3991 • Fax: (716) 542-3996 • E-mail: sales@eriemetal.comNO. Description Date By

The information contained herein is the proprietary property of ERIE METAL SPECIALTIES, INC. No portion of it may be reproduced by any means or used in any form accept for the purpose for which it was intended. All rights of design and invention are hereby reserved.

Detailed by: Date:

BAF 10/21/17

Checked By: Date:

SLP 10/21/17

Scale: EMS Job #:

NTS

Sheet No.: Drawing No.:

ELCFC-100/100W

( ) - Denotes Millimeters

SEAL COLOR SELECTOR

BLACK _____ WHITE _____

BEIGE _____ GRAY _____

FLOOR - FLOOR/WALL SURFACE MOUNT CARPET SYSTEM

EXPOSED FINISH: MILL

MOVEMENT: +/- 25% JOINT WIDTH

STOCK LENGTHS: 10'-0"

13311 Main Road • Akron • New York • 14001 Descri ption D a t e By Phone: (716) 542-3991 • Fax: (716) 542-3996 • E-mail: sales@eriemetal.comNO.

The information contained herein is the proprietary property of ERIE METAL SPECIALTIES, INC. No portion of it may be reproduced by any means or used in any form accept for the purpose for which it was intended. All rights of design and invention are hereby reserved.

Detailed by: Date:

BAF 10/21/17

Checked By: Date:

SLP 10/21/17

Scale: EMS Job #:

NTS

Sheet No.: Drawing No.:

ELCFC-200

( ) - Denotes Millimeters

SEAL COLOR SELECTOR

BLACK _____ WHITE _____

BEIGE _____ GRAY _____

FLOOR - FLOOR/WALL SURFACE MOUNT CARPET SYSTEM

EXPOSED FINISH: MILL

13311 Main Road • Akron • New York • 14001 Descri ption D a t e By Phone: (716) 542-3991 • Fax: (716) 542-3996 • E-mail: sales@eriemetal.comNO.

The information contained herein is the proprietary property of ERIE METAL SPECIALTIES, INC. No portion of it may be reproduced by any means or used in any form accept for the purpose for which it was intended. All rights of design and invention are hereby reserved.

Detailed by: Date:

BAF 10/21/17

Checked By: Date:

SLP 10/21/17

Scale: EMS Job #:

NTS

Sheet No.: Drawing No.:

ELCFC-200W

( ) - Denotes Millimeters

SEAL COLOR SELECTOR

BLACK _____ WHITE _____

BEIGE _____ GRAY _____

FLOOR - FLOOR/WALL SURFACE MOUNT CARPET SYSTEM

EXPOSED FINISH: MILL

08 May 2026 Issued for Bid

SUBSTITUTION REQUEST FORM

TO: Alliiance, 400 Clifton Ave., Minneapolis, MN 55403 ATTN: Linda Landry PROJECT: Ticketing Renovation

SPECIFIED ITEM:

Section Page Paragraph Description

The undersigned requests consideration of the following:

PROPOSED

SUBSTITUTION:

(Note: Only one substitution per form.)

Attached description includes product description, specifications, drawings, photographs, performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified.

Attached data also includes a description of changes to the Contract Documents, which the proposed substitution will require for its proper installation.

The undersigned certifies that the following paragraphs, unless modified by attachments, are correct:

1. The proposed substitution does not affect dimensions shown on drawings.

2. The undersigned will pay for changes to the building design, including engineering design, detailing, and construction costs caused by the requested substitution.

3. The proposed substitution will have no adverse effect on the other trades, the construction schedule, or specified warranty requirements.

4. Maintenance and service parts will be locally available for the proposed substitution.

The undersigned further states that the function, appearance, and quality of the proposed substitution are equivalent or superior to the specified item.

Submitted by: For use by the design consultant:

Accepted Accepted as noted

Signature

Firm Not Accepted Received too late

Address By

Title

Date Date

Telephone Fax

Remarks:

Attachments:

Alliiance 01 60 00-1 Substitution Form

079500 2 2.5

- No Changes - Equal to specified product

Erie Metal Specialties, Inc.

13311 Main Rd. Akron, NY 14001

06/09/2026

716-542-3991

Drawings, Product Data

ENBW

INTERIOR WALL TYPE 1

BALCO 6GW

x

ENBW Series Seismic Glide System

The ENBW/w Seismic Glide System wall and ceiling expansion control system is capable of multi directional changes, as well as integrating with a variety of wall and ceiling surface treatments.

Seismic Glide is available in clear anodized aluminum to create a sleek look at an economical price.

FEATURES

COORDINATING CORNERS Available with corner option for a complete solution.

EASY ASSEMBLY After base plates are attached to the wall, the cover assembly snaps together for a tight fit.

DETAILS

MATERIAL 6063-T5 Aluminum

FINISH Clear Anodized

MOVEMENT

• Thermal: Horizontal and Vertical

• Seismic: Lateral Shear

MOUNTING Surface

JOINT SIZE 1 inch to 8 inches

LENGTH 10 Linear Feet

APPLICATION Interior

INSTALLATION Wall or Ceiling

OPTIONS Moisture Barrier, Fire Barrier

MODELS

Erie Metal Specialties, Inc. Phone: 716-542-3991 Website: www.eriemetal.com13311 Main Road

Akron, NY 14001 E-Mail: sales@eriemetal.com

Interior Joints (W all)

C H

N

IC

A L

D A

T A balcousa.com Toll Free: 1-800-767-0082 email: info@balcousa.com

6000 Series Wall and Ceiling Expansion Joint Coversers

A CSW Industrials Company

PRODUCT DESCRIPTION

Aluminum expansion joint cover designed for interior locations where metal covers are preferred for durability

IDEAL FOR

• Frequent thermal and seismic movement

• Applications where metal covers are preferred for durability

• Applications where walls are not parallel or perpendicular with each other

PERFORMANCE

Joint Sizes 1”– 12” (25mm - 305mm) Movement Capabilities Permits unrestrained movement of the joint without disengagement of the cover.

MATERIALS

• Aluminum extrusions: 6063-T5, ASTM B221

• Aluminum plate: 5005-H34, ASTM B209

• Standard fasteners provided for assembly and installation

• All surfaces in contact with masonry or concrete will be protected by a factory-applied coating.

*Lateral shear movement requires specific accommo-dations at wall terminations, contact factory for details.

**Shear values are for wall installation; ceiling is opposite.

ADVANTAGES

• Seismic movement without disengagement of cover

• Easy to clean and maintain

• No exposed fasteners

• Can be painted to match adjacent construction

• Center plate can be formed to accommodate custom corners

OPTIONS

• Flush or surface mounted installation

• Water barrier

• Fire barrier

LIMITATIONS

• Provided in 10’-0” (3048mm) maximum lengths

FINISHES

Standard Cover: Architectural class II clear anodized Base extrusion: Mill finish Optional***

• Color anodized aluminum cover

• Cover primed for finish painting in field

• Mill finish aluminum cover

***Extended lead times and additional costs may apply

Model Application 6GW Flush-mounted wall 6GWC Flush-mounted corner wall 6TW Surface-mounted wall 6TWC Surface-mounted corner wall 6GWFC Flush-mounted corner wall 6TWFC Surface-mounted corner wall

6000 SERIES WALL MODEL GUIDE

Lateral shear*±5 0%

±1

Expansion/contraction±100% ±50%

Vertical shear** Contact factory for details

VARIES

Per ASTM E1399

SEISMIC WINDTHERMAL

Rev. 04/23 balcousa.com email: info@balcousa.com

6000 Series Wall and Ceiling Expansion Joint Covers

RELATED PRODUCTS

• 6000 series floor covers

• XH4FS heavy-duty floor covers

• SS6000 series covers

ADDITIONAL DOCUMENTATION

• Product details

• Installation instructions

• Maintenance and cleaning

• ASTM E1399

• Warranty

• MSDS documentation

• LEED documentation

WARRANTY

Standard Warranty: 5 years Sample warranty available upon request.

ENBW-Series Installation Instructions

Erie Metal Specialties, Inc.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .