About this file
This is an Access Requirements document for the Solano County Asset Protection Project, a multi-location concrete masonry and stormwater protection initiative affecting ten county properties across Union Avenue, Clay Street, Delaware Street, and Texas Street. The document establishes vehicle and pedestrian access protocols for construction activities at critical county facilities including the Hall of Justice, Solano County Emergency Services, Solano Detention Facility, Sheriff's Office, and related administrative buildings. Vehicle access is categorized into three levels: Category A Critical Emergency Vehicle Access Points must remain open 24 hours per day, 7 days per week with immediate mitigation required for any disruptions; Category B Important Operational Vehicle Access Points require a minimum two-week notice before disruption with potential alternate access provisions; and Category C Major Traffic Access Ways require a minimum three-week notice with traffic control plans and encroachment permits. Pedestrian access points are similarly designated, with major public and staff entry points requiring three-week notice and an Accessible Alternate Pedestrian Access Plan, secure staff entry points requiring two-week notice, and possible egress points requiring two-week notice with fire marshal-approved exit plans.
The construction phasing diagram illustrates the specific locations of access requirements, parking area designations, and maintenance access points throughout the multi-building complex. Contractors must carefully coordinate all construction activities to maintain uninterrupted access to emergency vehicle routes, particularly the Sally Port entrances, loading bays, and sheriff response vehicle parking areas. The access requirements impose strict notice and planning obligations on contractors to ensure continuity of operations for law enforcement, emergency services, and court facilities during the concrete masonry construction and stormwater protection work.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AREA LITE
AREA LITE
NO
PARKING
RESERVED
RESERVED
NO
PARKING
RESERVED
NO
PARKING
NO
PARKING
NO
PARKING
NO
PA
RK
IN
G
NO
PARKING
NO
PARKING
NO
PARKING
NO
PARKING
B
BB
B
B
B
B
B
B
B
B
B
B
B
B
B
BB
B
B
B
B
B
B
B
B
B
B
BB
B
B
NO
PA
RK
IN
G
NO
PARKING
NO
PARKING
CR
IC
C R
IC IC
IC
IC
C R
C R
C R
CR
IC
IC
CR
C R
C R
C R
CR
IC
IC
IC
IC
CR
C R
CR
C R
C R
CR
C R
C R
CONSTRUCTION
PHASING
X:
\1
\1
4.
\T
EC
H \C
AD
\P
AR
KI
N G
L O
T
IM
PR
O
VE
M
EN
TS
\G -0
C
O N
ST
R
U C
TI
O
N P
H
AS
IN
G
.D W
G
/2
1/
:4 9:
P
M
SHEET CONTENTS
or l
00 60 120
Vehicle Access Points
A Critical Emergency Vehicle Access Point.
Must remain open to large vehicle access 24 hours a day, 7 days a week. Any disruption to vehicle access route will require immediate mitigation.
B Important Operational Vehicle Access Point. Contractor to provide minimum 2 week notice prior to any activities disrupting access or vehicle route. Alternate access provisions by contractor may be required
C Major Traffic Access Way. Contractor to provide minimum 3 week notice prior to any activity disrupting access. A traffic control plan & encroachment permits are required.
Pedestrian Access Points
1 Major public & staff entry point. Contractor to provide minimum 3 week notice prior to any construction activities disrupting access. An Accessible Alternate Pedestrian Access Plan will be required.
2 Secure Staff entry point. Contractor to provide minimum 2 week notice prior to any activities disrupting access. An Accessible Alternate Pedestrian Access Plan may be required.
3 Possible egress point. Contractor to provide minimum 2 week notice prior to any activities disrupting egress. An alternate exit plan with fire marshal approval may be required.
501 Texas Co-Op Extension / Sheriff Investigations
600 Union Ave Hall of Justice North Wing
600 Union Ave Hall of Justice South Wing
530 Union Ave Solano Justice Center 530 Clay St
Solano County Emergency Services
500 Union Ave Solano Detention Facility
512 Clay St Sheriff Professional Standards
500 Clay St Communications
501 Delaware St Cogeneration Plant
512 Clay St Emergency Services Vehicle Storage
520 Clay st Solano Coroner's Office
Delaware Street
A
A
B
JCDF Sally Port Entrance
Coroner Sally Port Entrance
JCDF
Loading Bay
A JCDF Sally Port Entrance
B OES &
Facilities Vehicles
B
OES &
Facilities Vehicles
B Cogen Loading Bay
C
Washington Street C
Clay Street C
Access Requirements
B
Court Maintenance Area
B Judges Parking
B Sheriff Response Vehicle Parking
B Sheriff Response Vehicle Parking
OES Entry
Office of Professional Standards2 Staff
Entrance
2 Communications
Court Entry
1 Court Entry
1 JCDF
Entry
B Loading Bay
Coop & Sheriff Investigations
B
Maintenance Access
2 Maintenance
2 Maintenance
JCDF
Release Point
B Loading Bay
Staff Entry
2 Staff
Entry
B
Loading Bay
2 Staff Entry
B Loading Bay
2 Staff Entrance
2 Staff Entrance
2 Staff Entrance
A Sally Port
2 Staff Entrance
Staff Entrance
2 Staff Entrance
Staff Entrance 3