ACCESS CONTROL LISTfor bidding.xlsx
XLSX spreadsheet 19 KB Posted
- Attached to
- NEJC17004 Access Control System
- Solicitation number
- IFB1 GJRA 2017000060 1
- Issued by
- Lincoln County, Colorado
About this file
This is an Access Control List specification document for a campus access control system upgrade project involving multiple buildings across what appears to be an educational institution. The project encompasses the installation and conversion of access control equipment across numerous facilities including Cosmetology, Family Lit, Essence French, Phillips Wyman, Knowles Hall, Cafe, Hays Student Center, Walker Hall, Beede Hamill, Votech, Lebsach Smidt, and Welding buildings, as well as auxiliary-funded locations such as Williams GRB, Poole Hall, Event Center, Blue Spruce, Dowis Hall, and Herbie Hall. The scope includes installing controllers, readers, electric strikes, door contacts, PIR sensors, and electrified exit devices across approximately 50 doors. Work involves both new installations and conversions of existing equipment, with multiple doors requiring hardware migration from General Electric systems to Hartland systems. Several doors will utilize Stanley sliding doors with access control equipment added per manufacturer specifications, and specific equipment conversions to QEL-based systems are detailed with associated kit numbers for varying door widths.
The project is divided into two funding categories: General Funded and Auxiliary Funded work. Equipment specifications are highly detailed, with standardized controllers (RTS-MULTIDRIP series in various configurations) and readers (APTIQ MT models) specified for most locations. Existing VD99 exit devices are being retained on many doors within auxiliary-funded buildings where hardware migration is occurring. Specialized installations include magnetic locks, automatic operator tie-ins, and request-to-exit push buttons at select locations. The document serves as a technical specification guide for bidders, establishing the exact equipment configurations, quantities, and installation requirements needed for the comprehensive campus access control system upgrade.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| BUILDING | DOOR # | CONTROLLER | READER | ELECTRIC STRIKE | DOOR CONTACT | PIR | ELECTRIFIED EXIT DEVICE | AMORED LOOP | NOTES |
| GENERAL FUNDED | |||||||||
| Cosmetology | COS-1 | RTS-MULTIDRIP-08 | APTIQ MT 15 | ADD | ADD | ADD | NO | NO | |
| Cosmetology | COS-2 | APTIQ MT 15 | ADD | ADD | ADD | NO | NO | ||
| FAMILY LIT | FL-1 | RTS-MULTIDRIP-08 | APTIQ MT 15 | NO | ADD 2 | ADD | NO | NO | ACCESS CONTROL ON RIGHT DOOR DOOR CONTACTS ON BOTH ALSO NEEDS MAG LOCK |
| ES FRENCH | ESF-1 | RTS-MULTIDRIP-08 | APTIQMT11 | NO | ADD2 | ADD | CONVERT | ADD | EXISTING VD99 CONVERT TO VD 99 QEL * |
| ESF-2 | APTIQMT11 | NO | ADD2 | ADD | CONVERT | ADD | EXISTING VD99 CONVERT TO VD 99 QEL * | ||
| ESF-3 | APTIQMT11 | NO | ADD | ADD | CONVERT | ADD | EXISTING VD99 CONVERT TO VD 99 QEL * | ||
| ESF-4 | APTIQMT11 | NO | ADD | ADD | CONVERT | ADD | EXISTING VD99 CONVERT TO VD99 QEL* | ||
| ESF-5 | APTIQMT11 | NO | ADD | ADD | CONVERT | ADD | EXISTING VD99 CONVERT TO VD99 QEL* | ||
| ESF-6 | APTIQMT11 | NO | ADD | ADD | CONVERT | ADD | EXISTING VD99 CONVERT TO VD99 QEL* TIE ACS TO AUTO OPERATOR | ||
| PHILLIPS WYMAN | PW-1 | RTS-MULTIDRIP-08 | APTIQMT11 | NO | ADD | ADD | COVERT | ADD | EXISTING VD99 CONVERT TO VD 99 QEL* TIE ACS TO AUTO OPERATOR |
| PW-2 | APTIQMT11 | NO | NO | NO | NO | NO | WILL BE A STANLEY SLIDING DOOR ADD ACCESS CONTROL EQUIPMENT PER SPECS | ||
| PW-3 | APTIQMT15 | ADD | ADD | ADD | NO | NO | |||
| KNOWLES HALL | KH-1 | RTS-MULTIDRIP-08 | APTIQMT11 | NO | NO | NO | NO | NO | WILL BE A STANLEY SLIDING DOOR ADD ACCESS CONTROL EQUIPMENT PER SPECS |
| KH-2 | APTIQMT11 | NO | NO | NO | NO | NO | WILL BE A STANLEY SLIDING DOOR ADD ACCESS CONTROL EQUIPMENT PER SPECS | ||
| KH-3 | APTIQMT11 | NO | NO | NO | NO | NO | WILL BE A STANLEY SLIDING DOOR ADD ACCESS CONTROL EQUIPMENT PER SPECS | ||
| CAFÉ | CAFÉ-1 | RTS-MULTIDRIP-08 | APTIQMT11 | NO | NO | NO | NO | NO | EXISTING AUTO SLIDER ADD ACCESS CONTROL EQUPMNET PER MANUFACTURER SPECS |
| HAYS STUDENT CENTER | HSC-1 | RTS-MULTIDRIP-08 | APTIQMT11 | NO | NO | NO | NO | NO | WILL BE A STANLEY SLIDING DOOR ADD ACCESS CONTROL EQUIPMENT PER SPECS |
| HSC-2 | APTIQMT11 | NO | NO | NO | NO | NO | WILL BE A STANLEY SLIDING DOOR ADD ACCESS CONTROL EQUIPMENT PER SPECS | ||
| WALKER HALL | WH-1 | RTS-MULTIDRIP-08 | APTIQMT11 | NO | NO | NO | NO | NO | WILL BE A STANLEY SLIDING DOOR ADD ACCESS CONTROL EQUIPMENT PER SPECS |
| WH-2 | APTIQMT11 | NO | NO | NO | NO | NO | WILL BE A STANLET SLIDING DOOR ADD ACCESS CONTROL EQUIPMENT PER SPECS | ||
| WH-3 | APTIQMT15 | ADD | ADD | ADD | NO | NO | |||
| BEEDE HAMILL | BH-1 | RTS-MULTIDRIP-08 | APTIQMT11 | ADD | ADD | ADD | NO | NO | |
| BH-2 | APTIQMT11 | ADD | ADD | ADD | NO | NO | |||
| VOTECH | AV-1 | RTS-MULTIDRIP-08 | APTIQMT15 | NO | ADD2 | ADD | CONVERT | ADD | EXISTING VD99 CONVERT TO VD99 QEL* |
| AV-2 | APTIQMT15 | NO | ADD2 | ADD | CONVERT | ADD | EXISTING VD99 CONVERT TO VD99 QEL* | ||
| AV-3 | APTIQMT15 | NO | ADD | ADD | CONVERT | ADD | EXISTING VD99 CONVERT TO VD99 QEL* | ||
| AV-4 | APTIQMT15 | NO | ADD | ADD | CONVERT | ADD | EXISTING VD99 CONVERT TO VD99 QEL* | ||
| LEBSACH SMIDT | LS-1 | RTS-MULTIDRIP-08 | APTIQMT15 | NO | ADD2 | ADD | NO | NO | ADD MAG LOCK AND REQUEST TO EXIT PUSH BUTTON |
| LS-2 | APTIQMT15 | NO | ADD | ADD | CONVERT | ADD | EXISTING VD99 CONVERT TO VD99 QEL* | ||
| LS-3 | APTIQMT15 | NO | ADD | ADD | CONVERT | ADD | EXISTING VD99 CONVERT TO VD99 QEL* | ||
| WELDING | WRI-1 | APTIQMT15 | NO | ADD | ADD | ADD VD QEL 99 | NO | WRI-400 TO BE MOUNTED ON EXTERIOR OF WELDING PIM 400-TD2 TO BE MOUNTED OM | |
| EXTERIOR OF LEBSACH WHICH WILL CONNECT TO ACCES CONTROL IN LS | |||||||||
| * WERE NOTED TO CONVERT TO QEL USE THE FOLLOWING KIT NUMBERS | |||||||||
| FOR 3 FOOT DOOR 958003-00 QEL BASEPLATE KIT | |||||||||
| FOR 4 FOORT DOOR 040065-00 QEL BASEPLATE KIT |
Sheet2
| BUILDING | DOOR # | CONTROLLER | READER | ELECTRIC STRIKE | DOOR CONTACT | PIR | ELECTRIFIED EXIT DEVICE | NOTES |
| AUXILLARY FUNDED | ||||||||
| WILLAIMS GRB | WGRB-1 | RTS-MULTIDRIP-08 | APTIQMT15 | NO | NO | NO | EXISTING VD99 | ON EXISTING SYSTEM READER TO BE REPLACED HARDWARE MIGRATED FROM GE TO HARTLAND |
| POOLE HALL | PL-1 | RTS-MULTIDRIP-08 | APTIQMT15 | NO | NO | NO | EXISTING VD99 | ON EXISTING SYSTEM READER TO BE REPLACED HARDWARE MIGRATED FROM GE TO HARTLAND |
| PL-2 | APTIQMT15 | NO | NO | NO | ADD VD 99 QEL | EXISTING DOOR TO BE REPLACED WITH DOUBLE AL DOOR WITH CENTER MULLION | ||
| EVENT CETER | EC-1 | RTS-MULTIDRIP-08 | APTIQMT15 | NO | ADD | ADD | ADD VD 99 QEL | REPLACE EXISTING EXIT DEVICE ON LEFT SINGLE DOOR |
| EC-2 | APTIQMT15 | NO | ADD | ADD | ADD VD 99 QEL | REPLACE EXISTING EXIT DEVICE ON LEFT SINGLE DOOR | ||
| EC-3 | RTS-MULTIDRIP04WL | CONVERT TO AD400 | NO | NO | NO | NO | EXISTING AD 200E C-3 AND 4 WILL LINK TO SAME PIM 400-485 TO ALLOW FOR FUTURE EXPANSION | |
| EC-4 | Transmitter PIM | AD400 CL | NO | NO | NO | NO | CONNECT TO PIM AS NOTED ABOVE | |
| EC-5 | RTS-MULTIDRIP04WL | CONVERT TO AD400 | NO | NO | NO | NO | EXISTING AD200 EC-5,6,AND 7 WILL CONNECT TO SAME PIM 400-485 FOR FUTURE EXPANSION | |
| EC-6 | Transmitter PIM | AD400 CL | NO | NO | NO | NO | SEE EC-5 | |
| EC-7 | Transmitter PIM | AD400 CL | NO | NO | NO | NO | SEE EC-5 | |
| BLUE SPRUCE | BS-1 | RTS-MULTIDRIP-16 | APTIQMT15 | NO | NO | NO | EXISTING VD99 | ON EXISTING SYSTEM READER TO BE REPLACED HARDWARE MIGRATED FROM GE TO HARTLAND |
| BS-2 | APTIQMT15 | NO | NO | NO | EXISTING VD99 | ON EXISTING SYSTEM READER TO BE REPLACED HARDWARE MIGRATED FROM GE TO HARTLAND | ||
| BS-3 | APTIQMT15 | NO | NO | NO | EXISTING VD99 | ON EXISTING SYSTEM READER TO BE REPLACED HARDWARE MIGRATED FROM GE TO HARTLAND | ||
| BS-4 | APTIQMT15 | NO | NO | NO | EXISTING VD99 | ON EXISTING SYSTEM READER TO BE REPLACED HARDWARE MIGRATED FROM GE TO HARTLAND | ||
| BS-5 | APTIQMT15 | NO | NO | NO | EXISTING VD99 | ON EXISTING SYSTEM READER TO BE REPLACED HARDWARE MIGRATED FROM GE TO HARTLAND | ||
| BS-6 | APTIQMT15 | NO | NO | NO | EXISTING VD99 | ON EXISTING SYSTEM READER TO BE REPLACED HARDWARE MIGRATED FROM GE TO HARTLAND | ||
| BS-7 | APTIQMT15 | NO | NO | NO | EXISTING VD99 | ON EXISTING SYSTEM READER TO BE REPLACED HARDWARE MIGRATED FROM GE TO HARTLAND | ||
| DOWIS HALL | DRH-1 | RTS-MULTIDRIP-08 | APTIQMT15 | NO | NO | NO | EXISTING VD99 | ON EXISTING SYSTEM READER TO BE REPLACED HARDWARE MIGRATED FROM GE TO HARTLAND |
| DRH-2 | APTIQMT15 | NO | NO | NO | EXISTING VD99 | ON EXISTING SYSTEM READER TO BE REPLACED HARDWARE MIGRATED FROM GE TO HARTLAND | ||
| HERBIE | HRH-1 | RTS-MULTIDRIP-08 | APTIQMT15 | NO | NO | NO | EXISTING VD99 | ON EXISTING SYSTEM READER TO BE REPLACED HARDWARE MIGRATED FROM GE TO HARTLAND |
File details come from the government source that posted it. Updated .