Text version
NOAA MARINE OPERATIONS CENTER
2002 SE Marine Science Drive
Newport, Oregon 97365
Wayne K Larson, P.E.
Product Line Manager, Hydro wayne.larson@noaa.gov
(541) 867-8715
A1
RA-S2001-3
12/02/2014
NTS
NOAA SHIP RAINIER
COM-7X Winch Installation
"E" Deck Plan View
NOTES:
1. SEE NOAA DWG RA-S1113-30 COM-7X WINCH FOUNDATION FABRICATION FOR WINCH FOUNDATION DETAIL
2. SEE MARKEY DWG C35815 FOR WINCH SILL PLAN AND MECHANICAL DETAIL
3. MOUNT WINCH JUST OFFSET TO PORT OF C/L SUCH THAT NAVIGATION LIGHT STRUCTURE DOES NOT INTERFERE WITH LEVEL WIND TRAVEL OR CABLE PAYOUT
4. MOUNT WINCH AFT AS FAR AS POSSIBLE ON E DECK AS CONSTRAINED BY FOUNDATION DETAIL REQUIREMENTS.
4. MODIFY DECK RAILING AFT OF WINCH SUCH THAT IT DOES NOT INTERFERE WITH LEVEL WIND TRAVEL OR CABLE PAYOUT.
5. PROVIDE SIX KICK-PIPETYPE DECK PENETRATIONS FOR SLIP RING ASSEMBLY COAX, PENDENT BOX CONTROL, VFD DRIVE, RESISTOR BANK, BRAKE AND REMOTE OPERATOR STATION CABLES. LOCATE DECK
PENETRATIONS AFT OF FRAME 99, FORWARD OF WINCH AUTO BRAKE AND JUST INBOARD OF SLIP RING ASSEMBLY PENETRATIONS FOR COAX AND REMOTE OPERATOR STATION TO REMAIN EMPTY. CONTRACTOR TO
SUPPLY ALL OTHER CABLING.
6. PROVIDE A RAIN-TIGHT FIBERGLASS ENCLOSURE IN WHICH TO HANG AND STORE THE LOCAL CONTROL PENDANT. THE ENCLOSRE IS TO HAVE A FRONT LATCHING DOOR, AN EDGE PROTECTED CABLE WAY SLOT IN
THE BOTTOM AND A HOOK OR FORK TO HANG THE PENDANT. MOUNT PER COR DIRECTION.
NEW
COM-7X
WINCH
LOCATION
(SEE NOTES)
NOAA MARINE OPERATIONS CENTER
2002 SE Marine Science Drive
Newport, Oregon 97365
Wayne K Larson, P.E.
Product Line Manager, Hydro wayne.larson@noaa.gov
(541) 867-8715
NOAA SHIP RAINIER
COM-7X Winch Installation
"C" Deck Plan View
A2
RA-S2001-3
02/16/2014
NTS
NOTES:
1. SEE MARKEY DRAWING 22349 PRELIMINARY SYSTEM OVERVIEW. ALL CABLING INDICATED BY THIS MANUFACTURER'S REFERENCE DRAWING AS CUSTOMER SUPPLIED CABLING IS TO BE PROVIDED UNDER THIS
CONTRACT AS PART OF THE INSTALLATION (NOT GOVERNMENT PROVIDED). THREE PHASE POWER CABLING IS TO BE 4-4 SEOW. DRIVE CABLING TO BE AMERCABLE 37-102-516VFD. GENERAL CABLING TO BE LSSGU IN
SIZES AS INDICATED. SHIELDED 16 - #16 CABLE TO BE MARINE GRADE, LOW SMOKE, INTRUMENTATION CABLE. PROVIDE, MOUNT AND CONNECT ALL NECESSARY CABLES AND CABLE WAY HARDWARE.
2. MOUNT WINCH DRIVE CABINET (42 X 36 X 12 IN) ON AFT BULKHEAD OF OCEANOGRAPHIC LAB AT A WORKING HEIGHT BETWEEN DOORWAY AND DIVE LOCKER. REMOVE HAND HELD RADIO MOUNTS AND AN OTHER
MINOR INTERFERENCES AND PROVIDE TO COR PROVIDE MOUNTING HARDWARE. DRIVE CABINET IS GFE
3. PROVIDE AND INSTALL A PROPERLY SIZED MCT FOR CABLES TO PENETRATE THE BULKHEAD OF THE OCEANOGRAPHIC LAB. ROUTE CABLES TO WINCH DRIVE CABINET FROM E DECK PENETRATION VIA OVERHEAD OF
D DECK APPROXIMATELY AS SHOWN.
4. PROVIDE TWO KICKPIPE DECK PENETRATIONS FOR DRIVE CABINET THREE PHASE 480 V, 15 A POWER AND SINGLE PHASE 120 V, 3 A POWER JUST AFT FRAME 97.
5. RUN THREE PHASE 480 V POWER CABLING FROM DRIVE CABINET THRU D DECK PENETRATIONS TO EXISTING CABLEWAY IN THE OVERHEAD OF C-10-001 SURVEY STORES TO THE P403 AFT DECK MACHINERY POWER
PANEL ON THE AFT BULKHEAD.
DRIVE CABINET
MCT
PENETRATIONS DOWN TO
C DECK
PENETRATIONS
UP TO E DECK