A5.01-INTERIOR_ELEVATIONS~1.pdf
PDF 1 MB Posted
- Attached to
- OCYCF Med/Dental Remodel
- Solicitation number
- S-DASOBO-00001428
- Issued by
- Lake County, Albany City, Oregon
About this file
This document is an interior elevation drawing set related to a state and local contract opportunity for the Oregon Youth Authority's Oak Creek Expansion project in Albany, Oregon. The project involves the remodel of the medical and dental areas, including interior elevations and equipment specifications for various rooms such as the waiting area, nurse station, dental exam rooms, and medical exam rooms. The drawings depict the layout and specifications for cabinets, countertops, fixtures, and medical/dental equipment to be installed. This contract opportunity is in the jurisdictions of Marion County and the City of Salem, Oregon.
The contract appears to be for the construction and renovation work required to complete the medical and dental remodel portion of the Oak Creek Expansion project. No specific pricing, set-aside, incumbent, or funding details are provided in the drawing set. However, the comprehensive interior elevation drawings suggest this is a substantial project with multiple specialized rooms and equipment to be furnished and installed by the selected contractor.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CD
A7.01
A7.01
A7.01
A7.01
AEDE
A7.01
A7.01
CPU
DC
A7.01
A7.01
A7.01
A7.01
CPUCPUCPU
F
2'-2 3/4" EQ EQ
3' -0
1'
-6
2' -6
A7.01
A7.01
1'-5 1/4" 2'-10" 2'-10"
REF-U
MICRO
PTD
SD
T
SCD
MIR
SND TPD
GLD
2' -0
2'
-0
3' -0
2'-6" 5'-10 3/4"
CPUSD
PTD
XRAY
EQ EQ EQ
EQ EQ EQ
A7.01
A7.01
A7.01
A7.01
HS
3' -0
4'
-0
EQ EQ EQ
7'-9 1/4"
SD
PTD
GLD
USC
EQ EQ
SHP
A7.01
A7.01
A7.01
2'-6"
1'-8 1/4" 2'-6"
3'-0" 4'-2 1/4"
ATC
A7.01
A7.01
A7.01
EQ EQ
1' -6
2'
-6
PTD
SD GLD
EQ EQ
A7.01
A7.01 6
A7.01
SHP
DP MAYO
T
WMC
EQ EQ EQ
2' -6
1'
-6
3' -0
1'-6" EQ EQ 1'-6"
8'-8 3/4"
A7.01
A7.01
A7.01
HS
EQ EQ EQ
7'-8 1/4"
2' -0
6"
1' -6
3'
-0
1'-7"
PTD
GLD SD
CT-SP
SHP
A7.01
A7.01
A7.01
CLR.
2'-6"
3' -0
2'
-0
/4
2'-10"
REF
2'-9" 1'-9 1/2"
A7.01
A7.01
OFOI - OWNER FURNISHED, OWNER INSTALLED
LEGEND
OFCI - OWNER FURNISHED, CONTRACTOR INSTALLED
CFCI - CONTRACTOR FURNISHED, CONTRACTOR
INSTALLED
UNDER CABINET LIGHT FIXTURE
VENDOR FURNISHED EQUIPMENT
3' -0
PASS
3'-6 1/4"
A7.01
3' -0
2'
-0
2' -0
CNMS
EQ EQ
SHP
GLDPTD
SD
2'-6"
REF-U
A7.01
A7.01
EW
SC
PRPR
PTD
SDSCD
T
MIR
SND TPD
A7.01
3'-0"
7' -0
PROJECT NO.:
ISSUE DATE:
REVISIONS:
C
LA
R K
K
JO
S A
R C
H
IT
E C
T S
LL
C
C
O P
Y R
IG
H
T
S W
A ld er S t., S ui te
P or tla nd
, O R
P ho ne
: 5
/2
-4
/1
/2
:2
:2
A
M
INTERIOR ELEVATIONS
4.2.21
A5.01
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
20018
O A
K C
R E
E K
E X
P A
N S
IO
N
L
O C
H N
E R
R D
S E
A
L B
A N
Y O
R
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y
3/8" = 1'-0"A5.01
1 100 WAITING (E)
3/8" = 1'-0"A5.01
2 100 WAITING (N)
3/8" = 1'-0"A5.01
5 101 NURSE STATION (N)
3/8" = 1'-0"A5.01
6 101 NURSE STATION (W)
3/8" = 1'-0"A5.01
7 101 NURSE STATION (S)
3/8" = 1'-0"A5.01
9 102 FILE STORAGE (E)
3/8" = 1'-0"A5.01
24 111 PAT TLT (N)
3/8" = 1'-0"A5.01
25 111 PAT TLT (W)
3/8" = 1'-0"A5.01
10 104 DENTAL EXAM (S)
3/8" = 1'-0"A5.01
11 104 DENTAL EXAM (E)
3/8" = 1'-0"A5.01
12 104 DENTAL EXAM (N)
3/8" = 1'-0"A5.01
13 104 DENTAL EXAM (W)
3/8" = 1'-0"A5.01
14 103 DENTAL UTILITY (S)
3/8" = 1'-0"A5.01
15 103 DENTAL UTILITY (E)
3/8" = 1'-0"A5.01
19 109 MED EXAM (S)
3/8" = 1'-0"A5.01
18 109 MED EXAM (W)
3/8" = 1'-0"A5.01
17 109 MED EXAM (N)
3/8" = 1'-0"A5.01
16 109 MED EXAM (E)
3/8" = 1'-0"A5.01
20 110 MED UTILITY (N)
3/8" = 1'-0"A5.01
21 110 MED UTILITY (W)
EQUIPMENT LEGEND
AED AED BOX
ATC AUTOCLAVE
CN CENTRIFUGE
CPU COMPUTER
CT-SP SUPPLY CART
DP DUAL ADJUSTABLE PULLEY
EW EYE WASH
GLD GLOVE DISPENSER
HS HAND SANITIZER
MAYO MAYO STAND
MICRO MICROWAVE
MIR MIRROR
MS MICROSCOPE
PASS SPECIMEN PASS-THRU DOOR
PR PRINTER
PTD PAPER TOWEL DISPENSER
REF REFRIGERATOR
REF-U UNDERCOUNTER REFRIGERATOR
SC SCALE
SCD SEAT COVER DISPENSER
SD SOAP DISPENSER
SHP SHARPS CONTAINER
SND SANITARY NAPKIN DISPENSER
T TRASH CAN
TPD TOILET PAPER DISPENSER
USC ULTRASONIC CLEANER
WMC WALL MOUNTED COMPUTER
XRAY XRAY2GO MINI
GENERAL NOTES
1. CABINETMAKER SHALL COORDINATE WITH OTHER TRADES,
VENDORS AND OWNER FOR ITEMS INSTALLED IN AND AROUND
CABINETRY
2. GROMMETS AND ELECTRICAL OUTLETS: INSTALL GROMMETS IN
COUNTERTOPS FOR ALL UNDER-COUNTER OUTLETS AS FOLLOWS:
1 1/2" DIA. GROMMET FOR UP TO 2 OUTLETS
2 1/2" DIA. GROMMET FOR UP TO 4 OUTLETS
3. COORDINATE MOUNTING HEIGHTS FOR ALL SIGNAGE, EQUIPMENT
AND FIXTURES WITH STANDARD MOUNTING HEIGHT DRAWING.
4. PRIOR TO COVERING WALL, BACKING SHALL BE PROVIDED TO
ACCOMODATE ALL HUNG ITEMS AND ACCESSORIES CALLED FOR ON
THE CONSTRUCTION DOCUMENTS. SUCH ITEMS CONSIST OF, BUT
ARE NOT LIMITED TO: UPPERCASE CABINETS, STORAGE SHELVING,
TELEVISIONS, COMPUTER MONITORS, LAVATORY ACCESSORIES,
AND FUTURE INSTALLATION OF GRAB BARS AT THE SIDES OF WATER
CLOSETS.
3/8" = 1'-0"A5.01
22 112 SH/POCT (N)
3/8" = 1'-0"A5.01
23 112 SH/POCT (W)
3/8" = 1'-0"A5.01
8 101 NURSE STATION (E)
3/8" = 1'-0"A5.01
26 108 STAFF TLT (S)
3/8" = 1'-0"A5.01
27 108 STAFF TLT (E)
3/8" = 1'-0"A5.01
36 102 FILE STORAGE (W)
| Sheets |
| A5.01 - INTERIOR ELEVATIONS |