A5 4152VL06 Technical Ordering Data Sheet.pdf

PDF 113 KB Posted

Attached to
NUCLIDE GAMMA CALIBRATION
Solicitation number
4152-VL00
Issued by

About this file

This document appears to be an Ordering Data Sheet for a radioactive sealed beta reference source. The key details are:

The source is a 100 nCi Pm-147 sealed beta reference source in the form of a steel disk with an active element surrounded by an aluminum ring and aluminized Mylar window. The overall diameter is 47 mm with an active diameter of 41 mm and a height of 3.18 mm. The vendor must ensure the source activity does not exceed the exempt quantity per 10 CFR 30, and the reported radioactivity uncertainty must not exceed 5% at the 99% confidence level. Surface contamination levels must be less than 450 pCi/100cm^2.

A Certificate of Calibration is required that documents the source is NIST traceable, provides the total activity, activity of each nuclide, uncertainty value, reference time/date, activity of any gamma emitting impurities, the vendor assigned source serial number, ISO classification, and results of leakage testing. The source is to be shipped by the vendor to Puget Sound Naval Shipyard in Bremerton, WA. Prior to shipping, the vendor must make voice contact with the specified point of contact to provide shipment details.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ORDERING DATA SHEET – GENERAL

NOUN NAME: RADIOACTIVE SOURCES

DESCRIPTION:

1 ea Sealed beta reference source in the form of a steel disk with active element surrounded by an aluminum ring with 0.9 mg/cm^2 aluminized Mylar window. Overall diameter of 47 mm; Active diameter of 41 mm; Height of 3.18 mm.

-The source activity is 100 nCi (–10%, +10%) Pm-147.

-The vendor must insure that the source activity is not greater than exempt quantity per 10 CFR 30.

-The reported radioactivity uncertainty of each nuclide shall not exceed ± 5% at the 99% confidence level.

-Surface contamination levels on the source and packing materials must be less than 450 pCi/100cm^2.

MATERIAL: N/A

MANUFACTURER/VENDOR P/N: N/A

QUANTITY: 1 each

ADDITIONAL NOTES:

CERTIFICATION

-A Certificate of Calibration is required for the source and shall be provided from the vendor that documents:

-The source shall be National Institute of Standards and Technology (NIST) traceable

-The total activity of the source

-The activity of each nuclide in the source

-The uncertainty value, reference time and date

-The activity of any gamma emitting impurities detected

-The vendor assigned source serial number

-ISO Classification

-The results and date of leakage testing

SHIPPING REQUIREMENTS

Source will be shipped by vendor to:

(N4523A) Puget Sound Naval Shipyard & IMF

1400 Farragut Avenue, Building 514

Bremerton, WA 98314-5001

Attn: C/2380.4R - R. Nicole Van Den Eijkel (360) 801-6048

POC: C/105.55 Marc Sobolesky (360) 340-4797

Prior to shipping, vendor will make voice contact via phone with Nicole Van Den Eijkel or their representative at (360) 476-

3520 with date of shipment and shipment tracking information (i.e. UPS/FEDEX tracking numbers). A phone message will not be considered voice contact.

Changes to specification or other technical requirements are not allowed without Shipyard approval via the Administrative

Contracting Officer (ACO).

JOB ORDER

991566SOUR

KEY OP

H01

KO ITEM

REV

IDN

4152VL06

IDN REV

2305.3 Form; Rev 02/2020